RADIATION CONTROL - RADIATION SAFETY REQUIREMENTS FOR RADIATION GENERATING DEVICES NOT USED IN THE HEALING ARTS

ColoradoRegulations

Ask Donna

How this section applies to your facts.

Code of Colorado Regulations › 1000 Department of Public Health and Environment › 1007 Hazardous Materials and Waste Management Division › 6 CCR 1007-1 Part 08

This text was captured on Sep 30, 2026. It is a snapshot, not a live feed, so check the official code before relying on it.

Text

DEVICES NOT USED IN THE HEALING ARTS

6 CCR 1007-1 Part 08

[Editor’s Notes follow the text of the rules at the end of this CCR Document.]

_________________________________________________________________________

Adopted by the Board of Health June 16, 2021; effective August 14, 2021

PART 8:

RADIATION SAFETY REQUIREMENTS FOR RADIATION GENERATING DEVICES

NOT USED IN THE HEALING ARTS

8.1

Purpose and Scope.

8.1.1

Authority.

A.

Rules and regulations set forth herein are adopted pursuant to the provisions of sections

25-1-108, 25-1.5-101(1)(l), and 25-11-104, CRS.

8.1.2

Basis and Purpose.

B.

A statement of basis and purpose accompanies this part and changes to this part. A copy

may be obtained from the Department.

8.1.3

Scope.

A.

This part provides special requirements for non-healing-arts radiation generating devices

(RGDs) operating between 5 kiloelectron volts (keV) and 1 million electron volts (MeV).

For machines operating at energies greater than 1 MeV, see Part 9.

B.

The following machines and equipment are exempt from these regulations:

1.

Domestic television receivers.

2.

Cold-cathode gas discharge tubes, providing the exposure rates shall not exceed

10 mrem (0.1 mSv) per hour at a distance of thirty (30) centimeters from any

point on the external surface of the tube.

3.

Other electrical equipment that produces radiation incidental to its operation for

other purposes, providing the dose rate to the whole body at the point of nearest

approach to such equipment when any external shielding not integral to the

equipment is removed, does not exceed 25 mrem (0.25 mSv) per year. The

production testing or factory servicing for such equipment shall not be exempt.

4.

Equipment described in 8.1.3.B shall not be exempt if it is used or handled in

such a manner that any individual might receive a dose of radiation in excess of

the limits specified in Part 4 of these regulations.

C.

In addition to the requirements of this Part, all registrants are subject to the requirements

of Parts 1, 2, 4, 10 and 13 of these regulations. This Part does not pertain to radiation

safety requirements for x-ray equipment that is explicitly covered in other sections of

these regulations, such as Part 5 (Radiation safety requirements for industrial

radiographic operations), Part 6 (X-ray imaging in the healing arts), and Part 9 (Radiation

safety requirements for particle accelerators not used in the healing arts).

D.

Radiography that meets the definition of “cabinet radiography” as defined in 8.2 shall be

regulated under this Part. This includes certified x-ray systems.

E.

Radiography (excluding industrial radiography) that occurs in a shielded room as defined

in 8.2 shall be regulated under this Part.

F.

Industrial radiography that is open-beam, and not in a shielded room and not otherwise

listed in this section, shall be regulated under Part 5 of these regulations.

8.1.4

Applicability.

A.

The requirements and provisions of these regulations apply to applicants, and registrants

within the scope of by Part 8 unless specifically exempted by Part 8.

B.

The applicable special requirements of Part 5 also apply if an image receptor is used to

transform incident x-ray photons either into a visible image or into another form that can

be made into a visible image by further transformation.

C.

The requirements of Part 8 are in addition to, and not in substitution for, applicable

requirements in other parts of these regulations.

8.1.5

Intent.

RGDs are a broad class of equipment that generate x-rays or particle radiation having energies

between 5 keV and 1 MeV, and not intended for medical use on humans. If applicable, all RGDs

shall comply with FDA performance standards as defined in Title 21 Code of Federal Regulations,

parts 1010 thru 1050.

Examples of RGDs include, but are not limited to:

A.

Open and closed analytical x-ray equipment (table top and hand-held);

B.

X-ray gauges;

C.

Cabinet x-ray radiography;

D.

Security screening units;

E.

Quality or process control devices;

F.

Ion implantation devices;

G.

Electron beam welders; and

H.

Non-human use x-ray fluoroscopy.

8.1.6

Published Material Incorporated by Reference.

A.

Throughout this Part 8, federal regulations, state regulations, and standards or guidelines

of outside organizations have been adopted and incorporated by reference. Unless a

prior version of the incorporated material is otherwise specifically indicated, the materials

incorporated by reference cited herein include only those versions that were in effect as

of the most recent effective date of this Part 8 (August 2021), and not later amendments

or editions of the incorporated material.

B.

Materials incorporated by reference are available for public inspection, and copies

(including certified copies) can be obtained at reasonable cost, during normal business

hours from the Colorado Department of Public Health and Environment, Hazardous

Materials and Waste Management Division, 4300 Cherry Creek Drive South, Denver,

Colorado 80246. Additionally, https://www.colorado.gov/cdphe/radregs identifies where

the incorporated materials are available to the public on the internet at no cost. Due to

copyright restrictions certain materials incorporated in this Part are available for public

inspection at the state publications depository and distribution center.

C.

Availability from Source Agencies or Organizations.

1.

All federal agency regulations incorporated by reference herein are available at

no cost in the online edition of the Code of Federal Regulations (CFR) hosted by

the U.S. Government Printing Office, online at www.govinfo.gov.

2.

All state regulations incorporated by reference herein are available at no cost in

the online edition of the Code of Colorado Regulations (CCR) hosted by the

Colorado Secretary of State’s Office, online at

https://www.sos.state.co.us/CCR/RegisterHome.do.

8.2

Definitions.

8.2.1

Definitions of general applicability to these regulations are in Part 1, Section 1.2.

8.2.2

As used in Part 8, each term below has the definition set forth.

“Accessible surface” means the external or outside surface of the enclosure or housing provided

by the manufacturer. This includes high-voltage generator, doors, access panels, latches, control

knobs, and other permanently mounted hardware and including the plane across the exterior

edge of any opening.

“Analytical x-ray equipment” means equipment that generates (by electronic means) and uses

ionizing radiation for the purpose of examining the microstructure of materials, i.e., diffraction and

spectroscopy (including fluorescence).

“Baggage unit”. See “Security Screening Unit”.

“Beam-port” means an opening on the x-ray apparatus designed to emit a primary beam. This

does not include openings on baggage units.

“Cabinet radiography” means industrial radiography using radiation machines not subject to FDA

performance standard for cabinet x-ray systems, in an enclosed, interlocked cabinet in which the

portion of a material being irradiated is contained, and in which:

A.

The radiation machine will not operate unless all openings are closed with

interlocks activated;

B.

The cabinet is shielded such that every location on the exterior meets the

conditions for an unrestricted area as defined in Part 4 of these regulations; and

C.

The cabinet is constructed or arranged as to exclude the entrance of any part of

the body of an individual during irradiation.

“Cabinet x-ray system” means an x-ray system with the x-ray tube installed in an enclosure

which, independently of existing architectural structures except the floor on which it may be

placed, is intended to contain at least that portion of a material being irradiated, provide radiation

attenuation, and exclude personnel from its interior during generation of x radiation. Included are

all x-ray systems designed primarily for the inspection of bags, packages, and personal items at

airline, railroad, and bus terminals, and at other facilities for similar purposes. An x-ray tube used

within a shielded part of a building, or x-ray equipment which may temporarily or occasionally

incorporate portable shielding is not a cabinet x-ray system.

“Cathode ray tube” means any device used to accelerate electrons for demonstration or research

purposes, except where such cathode ray tube is incorporated into a television or display monitor

that is subject to, and has met applicable federal radiation safety performance standards in 21

CFR 1010 and 1020.10.

“Certified cabinet x-ray system” means a RGD certified by the manufacturer in accordance with

21 CFR 1010.2 as being manufactured and assembled pursuant to the provisions of applicable

federal radiation safety performance standards 21 CFR 1010 and 1020.40.

“Certifiable cabinet x-ray system” means an existing uncertified RGD that has been modified to

meet the certification requirements specified in 21 CFR 1020.40.

“Closed-beam x-ray equipment” means a system in which the beam path cannot be entered by

any part of the body during normal operation.

“Cold-cathode gas discharge tube” means an electronic device in which electron flow is produced

and sustained by ionization of contained gas atoms and ion bombardment of the cathode.

“Collimator” means a device for restricting the useful radiation in one or more directions.

“Control panel” means a device containing means for regulation and activation of a RGD or for

the preselection and indications of operating factors.

“Emergency procedure” means the written pre-planned steps to be taken in the event of actual or

suspected exposure of an individual in excess of administrative or regulatory limits. This

procedure shall include the names and telephone numbers of individuals to be contacted as well

as directives for processing the film badge or other personnel monitoring devices.

“Fail-safe design” means a design in which all realistically anticipated failures of indicators or

safety components result in a condition in which individuals are safe from exposure to radiation.

For example, if a light indicating “X-RAY ON” fails, the production of x-rays shall be prevented, or

if a shutter status indicator fails, the shutter shall close.

“General-use system” means a human body screening system that delivers an effective dose

equal to or less than 25 μrem (0.25 μSv) per screening. Given proper justification and certain

restrictions, general-use systems may be operated without specific controls that would limit the

number of individuals scanned or the number of scans per individual in a year.

“Hand-held x-ray system” means a portable instrument that is designed to operate when held in

the hand, such as a hand-held x-ray fluorescence (XRF) analytical device.

“Human body security screening system” means any x-ray equipment used on humans for

security evaluation purposes.

“Industrial radiography” means an examination of the structure of materials by nondestructive

methods utilizing ionizing radiation to make radiographic images for the purpose of detecting

structural flaws in objects. Industrial radiography does not include such imaging for education or

research purposes at a fixed location.

“Interlock” means a device or engineered system that precludes access to an area of radiation

hazard either by preventing entry or by automatically removing the hazard.

“Leakage radiation” means all radiation coming from within the source housing, except the useful

beam.

“Limited-use system” means a human body screening system that is capable of delivering an

effective dose greater than 25 µrem (0.25 µSv) per screening but cannot exceed an effective

dose of 1 mrem (10 µSv) per screening. Limited-use systems require additional controls and

documentation to ensure that annual individual dose limits required by 8.11.5 are not exceeded.

“Local components” means parts of a RGD x-ray system and include areas that are exposed to x-

rays, such as radiation source housings, beam port and shutter assemblies, collimators, sample

holders, cameras, goniometers, detectors, and shielding, but do not include power supplies,

transformers, amplifiers, readout devices, and control panels.

“Mobile equipment”. See “Radiation generating device.”

“Normal operating procedures” means a set of step-by-step instructions necessary to accomplish

the task. These procedures may include sample insertion and manipulation, equipment

alignment, routine maintenance by the registrant, and data recording procedures, which are

related to radiation safety.

“Open-beam x-ray equipment” means an open-beam x-ray system in which the beam path could

be entered by any part of the body at any time.

“Portable equipment”. See “Radiation generating device.”

“Primary beam” means the ionizing radiation coming directly from the radiation source through a

beam port into the volume defined by the collimation system.

“Qualified inspector” means an individual as defined in Part 1 of these regulations.

“Radiation generating device (RGD)” for purposes of Part 8, means any system, device,

subsystem, or component thereof, which may generate x-rays or particle radiation between 5 keV

and 1 MeV, and not intended for healing arts use for humans or animals. A RGD is x-ray

equipment (as defined in Part 1 of the regulations) that may be mobile, portable, or stationary.

“Radiation Safety Officer (RSO)” means an individual as defined in Part 1 of these regulations.

“Radiation source (or x-ray tube) housing” means that portion of an x-ray system which contains

the x-ray tube and/or secondary target. Often the housing contains radiation shielding material or

inherently provides shielding.

“Radiograph” means a permanent film or digital image produced on a sensitive surface by a form

of radiation other than direct visible light.

“Radiography” is the process of creating radiographic images.

“Safety device” means a device, interlock or system that prevents the entry of any portion of an

individual’s body into the primary x-ray beam or that causes the beam to shut off upon entry into

its path.

“Scattered radiation” means radiation that has been deviated in direction and / or energy by

passing through matter.

“Security screening unit” means a non-human use open-beam or cabinet x-ray system with

accessible openings designed for the detection of weapons, bombs, or contraband concealed in

baggage, mail, packages or other commodities or structure.

“Shielded room” means a room housing a RGD where, with the RGD at maximum exposure

setting, the exterior room environs meets the unrestricted area limits of 2 mrem (0.02 mSv) in any

one hour and 100 mrem (1 mSv) in a year at 30 centimeters from the barrier. A shielded room

does not include a RGD which meets the definition of cabinet x-ray systems.

“Shutter” means a moveable device used to block the useful (or primary) beam emitted from an x-

ray tube assembly.

“Source” means the point of origin of the radiation, for example, the focal spot of an x-ray tube.

“Stationary equipment”. See “Radiation generating device.”

“Stray radiation” means the sum of leakage and scatter radiation.

“Warning device” means a visible or audible signal that warns individuals of a potential radiation

hazard.

“X-ray generator” means that portion of an x-ray system which provides the accelerating high

voltage and current for the x-ray tube.

“X-ray gauge” means an x-ray producing device designed and manufactured for the purpose of

detecting, measuring, gauging, or controlling thickness, density, level, or interface location.

8.3

Administrative Requirements.

8.3.1

Each non-healing-arts radiation machine in the State of Colorado shall be registered with the

Department as required by Part 2, Section 2.4.

A.

In accordance with Part 2, such registration shall require:

1.

Designating a RSO;

2.

Maintaining documentation that a written shielding design has been completed,

as applicable.

Certified cabinet RGDs, hand-held XRF RGDs, and other systems as designated

in writing by the Department are not required to have a shielding design; and

3.

Inspection by a Qualified Inspector as required by Part 2, Section 2.5.

8.3.2

The registrant shall be responsible for directing the operation of the RGD(s) under their

administrative control and shall assure that the requirements of Parts 1, 2, 4, and 10 are met in

the operation of the system.

8.3.3

As provided in Part 2, Section 2.6.1.15, for any analytical, industrial or other non-healing-arts

RGD, “adequately trained” shall mean that the individual operator has met the requirements of

Part 2, Appendix 2N and any additional training requirements of Part 8.

8.3.5

Application for Exemptions.

Any RGD registrant that cannot meet the applicable requirements of this Part shall submit to the

Department a request for an exemption to the specific regulation or requirement in question. The

exemption request shall demonstrate to the Department’s satisfaction:

A.

That the use of the RGD will not result in undue hazard to public health and safety or

property;

B.

That compliance would require replacement or substantial modification of the RGD;

C.

That the registrant will achieve, through other means, radiation protection equivalent to

that required by the regulation; and

D.

Why the regulatory standard or requirement could not be met.

8.4

General regulatory requirements.

Unless otherwise provided in this Part, this Section 8.4 applies to all RGDs. Certified and

Certifiable Cabinet X-ray Systems as defined in this Part shall also meet the requirements of 21

CFR 1020.40.

8.4.1

Warning Devices.

A.

Warning devices shall be labeled so that their purpose is easily identified.

B.

An easily visible warning light labeled with the words “X-RAY ON”, or words/displays

having a similar intent, shall be located near any switch or control system that energizes

an x-ray tube and shall be illuminated only when the tube is energized. This warning

light/display shall be of a fail-safe design.

8.4.2

Labeling.

A.

All RGD equipment shall be labeled with a readily visible and discernible sign or signs

bearing the radiation symbol (in accordance with Part 4, Section 4.27) and the words:

“CAUTION - RADIATION - THIS EQUIPMENT PRODUCES RADIATION WHEN

ENERGIZED”, or words having a similar intent, near any switch that energizes an x-ray

tube.

B.

For RGDs with designed openings, for object entries (such as baggage units), the

following shall be posted at or near each opening: “CAUTION – X-RAY HAZARD: DO

NOT INSERT ANY PART OF THE BODY WHEN SYSTEM IS ENERGIZED”, or words

having similar intent.

8.4.3

Radiation Source Housing.

A.

Each radiation source housing shall be subject to the following requirements:

1.

Interlock.

When the x-ray tube housing is the primary shielding for the x-ray tube, and is

intended to be opened for normal use or maintenance, the housing shall be

equipped with an interlock that shuts off the high voltage to the x-ray tube if the

housing is opened; and

2.

Radiation emission limit.

Each x-ray tube housing shall be so constructed that, with all shutters closed, the

radiation measured at a distance of 5 centimeters from the x-ray tube housing

surface does not exceed 2.5 mrem (0.025 mSv) per hour This limit shall be met

at the maximum tube rating.

a.

For closed-beam RGDs, this requirement can be met by complying with

8.6.4, radiation emission limit (0.5 mrem or 0.005 mSv in one hour at five

centimeters outside any accessible surface).

b.

For a RGD in a shielded room, this limit can be met by measuring from

any accessible surface outside the room housing the RGD.

c.

For open-beam RGDs designed to be hand-held during operation, this

requirement can be met by complying with the limits in 8.8.3, radiation

emission limit (2.5 mrem or 0.025 mSv per hour at 5 centimeters.

8.4.4

Generator Cabinet or High Voltage Source Radiation Emission Limits

A.

Each x-ray generator or high-voltage source associated with an RGD shall be supplied

with a protective cabinet which limits leakage radiation to 0.25 mrem (2.5 µSv) per hour

at a distance of 5 centimeters measured at the nearest accessible surface.

1.

For closed beam systems, this requirement can be met by complying with

Section 8.6.4, radiation emission limit (0.5 mrem or 0.005 mSv in one hour at five

centimeters outside any accessible surface).

2.

For a RGD in a shielded room with the high-voltage generator also inside the

shielded room, this limit can be met by measuring from any accessible surface

outside the room housing the RGD. 3. For hand-held, open-beam RGDs, this

requirement can be met by complying with the limits in 8.8.3, radiation emission

limit (2.5 mrem or 0.025 mSv per hour at 5 centimeters).

8.4.5

Surveys.

A.

The registrant shall document performance of radiation surveys, as required by Part 4,

Section 4.17 of these regulations and shall be sufficient to show compliance with

radiation emission requirements of this Part, and as required by Part 4, Section 4.6 and

Part 4, Section 4.14 of these regulations. The radiation surveys shall be sufficient to

evaluate the magnitude and extent of radiation emissions and the potential radiological

hazards that could be present.

At a minimum, surveys shall be performed:

1.

Upon installation of the equipment, and at least once during each routine

certification evaluation thereafter;

2.

Following any change in the initial arrangement, number, or type of local

components in the system;

3.

Following any maintenance requiring the disassembly, removal, or repair of a

local component in the system;

4.

During the performance of maintenance, calibration and other procedures if the

procedures require the activation of a primary x-ray beam while any local

component in the system is disassembled or removed;

5.

Following the temporary bypass and restoration of a safety device or interlock

required by 8.4.7.B.

6.

Any time a visual inspection of the local components in the system reveals an

abnormal condition; and

7.

Whenever a personnel monitoring device shows a significant increase over the

previous monitoring period, or the readings are approaching the limits specified

in 4.6 of these regulations.

B.

The registrant shall have access to sufficiently calibrated, appropriate and operable

radiation survey instruments to make physical radiation surveys as required by this Part.

The instruments shall be capable of detecting and measuring the types and levels of

radiation involved (including primary, scattered, and leakage radiation).

C.

The registrant shall assure the maintenance and calibration of all monitoring and survey

instruments per Part 4, Section 4.17 of the regulations.

D.

Radiation survey measurements shall not be required if a registrant can otherwise

demonstrate compliance with the requirements of this Part to the satisfaction of the

Department.

8.4.6

Posting.

A.

Each area or room containing an RGD where an individual may receive 2 mrem (0.02

mSv) in any one hour or 100 mrem (1 mSv) per year shall be conspicuously posted with

a sign or signs bearing the radiation symbol (which meets the requirements of Part 4,

Section 4.27) and the words “CAUTION – X-RAY EQUIPMENT,” “CAUTION –

RADIATION GENERATING DEVICE” or words having a similar intent.

B.

Unless used in a dedicated location, hand-held RGDs are exempt from the requirements

of 8.4.6.A.

8.4.7

Security.

A.

When not in operation, RGDs shall be secured in such a way as to prevent access or

operation by unauthorized personnel.

8.4.8

Operating Requirements.

A.

Procedures.

1.

Normal operating procedures shall be written and available to all RGD operators.

2.

No individual shall be permitted to operate a RGD in any manner other than that

specified in the procedures unless such individual has obtained written approval

of the RSO and Department.

3.

Except as authorized under Part 6 for authorized medical purposes, or Section

8.11 for security screening purposes, intentional exposure of a living human to a

RGD for any purpose is strictly prohibited.

B.

Bypassing safety equipment.

1.

No individual shall bypass a safety device or interlock, unless such individual has

obtained the written approval of the RSO and Department. Such approval shall

be for a specified period of time.

2.

When a safety device or interlock has been bypassed, a readily discernible sign

bearing the words “SAFETY DEVICE NOT WORKING”, or words having a similar

intent, shall be placed on the radiation source housing and at the control switch.

3.

A record of any bypass of a safety device or interlock shall be maintained; the

record shall contain such information as the date the alteration was made, type of

alteration, length of time the unit remained in the altered condition, post bypass

survey and signed by the RSO, the individual who made the alteration, and the

individual who restored the unit to original condition.

4.

Control panel.

a.

The RGD can only be activated from a control panel.

b.

All indicators and controls that control the primary beam shall be

identifiable and discernible through the use of labels, symbols, software

displays or the equivalent.

C.

Interlocks.

1.

An interlock shall not be used to de-activate the x-ray tube or RGD, except in an

emergency or during testing of the interlock system.

2.

After triggering any interlock, it shall be possible to reset the RGD to full

operation only from a control panel.

3.

All interlocks shall be of a fail-safe design.

4.

When the system is in normal use, interlocks, including emergency shut off

controls, shall not be defeated, or otherwise made inoperable or inaccessible

such that the operability or primary purpose is impacted.

D.

Multiple sources.

If more than one x-ray tube assembly(s) or focal spot can be operated sequentially or

simultaneously from a control panel, visual indicators shall identify which tube

assembly(s) or focal spot has been selected. The selectors shall be identified as to their

function. If a letter or number is used, a reference card or table explaining the code shall

be affixed to the control panel.

8.4.9.

Repair or Modification of X-ray Tube or RGD Systems.

A.

Only registered service companies shall be permitted to install, repair, calibrate, or make

modifications to an RGD and only Qualified Inspectors shall perform machine

inspections.

B.

No operation involving removal of covers, shielding materials or tube housings or

modifications to shutters, collimators, or beam stops shall be performed without

ascertaining that the tube is off and will remain off until safe conditions have been

restored.

C.

The main power switch with a lock-out / tag-out, rather than interlocks, shall be used for

routine shutdown in preparation for repairs.

8.4.10. Testing of Safety Devices.

A.

Tests of all safety devices, such as interlocks, shutters, warning lights, and required

emergency shut-off switches shall be conducted at intervals not to exceed 6 months on

all operable RGDs. Cabinet integrity, where applicable, shall be evaluated at the same

time and frequency as safety device tests.

B.

If any safety device fails during testing, the RGD shall be removed from service until the

safety device failure is corrected or proper temporary administrative controls established

and approved in writing by the RSO.

C.

Records of safety device tests, check dates, findings and corrective actions shall be

available for inspection and maintained for 3 years.

D.

Records shall include the date of the test, a list of the safety devices tested, survey

instrument information, calibration date, the results of the test, the name of the person

performing the tests and corrective actions taken for safety devices that fail the required

test.

E.

Testing of safety devices may be deferred if the unit and/or installation is clearly marked

and kept out of service; units and/or installations brought back into service after

exceeding the 6 month interval shall be tested prior to use.

F.

If testing of a safety device cannot be performed due to manufacturer design, the

registrant shall document that the safety device will not be tested and specifically why the

safety device cannot be tested.

8.4.11 Instruction and Training.

The registrant shall document the scope of training required for the RGD they possess in

accordance with this section. No individual shall be permitted to operate or maintain an RGD, or

enter a shielded room without appropriate instruction and training. Records of all required training

and instruction shall be maintained onsite for a minimum of 3 years after the individual terminates

employment. Records shall be made available for review by the Department.

Each individual shall receive instruction in and demonstrated competence as to:

A.

Types of radiation and identification of radiation hazards associated with the use of the

RGD and associated equipment and precautions or measures to take to minimize

radiation exposure;

B.

Significance of the various radiation warning, safety devices, and interlocks incorporated

into the equipment, or the reasons they have not been installed on certain pieces of

equipment and the extra precautions required in such cases;

C.

Commensurate with potential hazards of use, biological effects of radiation, radiation

risks, and recognition of symptoms of an acute localized exposure;

D.

Normal operating procedures for each type of RGD and associated equipment, including

having received hands-on training, and procedures to prevent unauthorized use;

E.

Procedures for reporting an actual or suspected accidental exposure or other radiation

safety concerns, such as any unusual occurrence or malfunction that may involve

exposure to radiation; and

F.

Performing surveys where applicable.

8.4.12. Radiation Protection Responsibility.

A.

The registrant's senior management shall make the ultimate decision to use any RGD

and ultimately be responsible for radiation safety.

B.

The registrant's senior management shall designate an individual responsible for

radiation safety, or a RSO. This individual shall have direct access to senior management

for radiation safety issues. This individual shall have training and experience

commensurate with the scope of the radiation safety program to carry out the

responsibilities as indicated below.

1.

Ensuring that all RGDs are operated within the limitations of the established

radiation safety program and operating procedures.

2.

Instructing personnel with regard to safe working practices and ensuring all

personnel are trained in radiation safety commensurate with the hazards of the

job.

3.

Investigating any incident of abnormal operation or exposure or suspected

overexposure of personnel to determine the cause, take remedial action, and

report the incident to the proper authority.

4.

Ensuring that safety devices, interlocks, warning signals, labels, postings, and

signs are functioning and located where required.

5.

Maintain all radiation safety records.

8.5

Radiation levels and dosimetry monitoring.

8.5.1

Radiation Levels.

A.

X-ray equipment shall be located and arranged with sufficient shielding and area access

control to ensure compliance with Part 4.

B.

The registrant shall assure that no radiation levels exist in any area surrounding the local

component group which could result in a dose to an individual present therein in excess

of the dose limits in Part 4, Sections 4.14 or 4.15.

8.5.2

Personnel Monitoring Requirements.

A.

Each individual who is associated with the operation of a non-healing-arts radiation

generating device shall meet the requirements of Part 4, Sections 4.6, 4.10, 4.12, 4.13,

4.14, and 4.18.

1.

When personnel dosimetric monitoring devices are required, they shall be worn

in accordance with Part 4, Section 4.6.3.

2.

Each operator of portable hand-held x-ray equipment shall wear separate whole

body and extremity personnel dosimetric monitoring devices, unless otherwise

exempted by the Department or by regulation.

3.

Deliberate exposure of a personnel dosimetric monitoring device to deceptively

indicate a dose delivered to an individual is strictly prohibited.

B.

In addition to the requirements of Part 4, Section 4.6, extremity dosimetry shall be

provided to and shall be used by:

1.

Personnel working with or routinely working near and having potential for

extremity exposure to, the primary beam of an open-beam RGD; and

2.

Personnel maintaining RGDs if the maintenance procedures require the

activation of a primary x-ray beam when any local component in the x-ray system

is disassembled or removed.

8.6

Additional Requirements for Closed-Beam RGDs.

In addition to the requirements of 8.3, 8.4, and 8.5, the following applies to all closed-beam x-ray

RGDs:

8.6.1

System Enclosure.

The radiation source, sample or object, detector, and analyzing crystal (if used) shall be enclosed

in a chamber or coupled chambers that cannot be entered by any part of the body during normal

operation.

8.6.2

Interlocks.

All doors and panels accessing the RGDs shall be interlocked. The interlocks required by this

section shall be of a fail-safe design.

8.6.3

Interlock Functions.

The system enclosure, sample chamber, etc. closure shall be interlocked with the x–ray tube high

voltage supply and/or a shutter in the primary beam so that no x-ray beam can enter the sample

or object chamber while it is open unless the interlock has been conspicuously and deliberately

defeated. The interlock required by this section shall be of fail–safe design or adequate

administrative controls shall be exercised to ensure operations will not continue without a proper

functioning interlock.

8.6.4

Radiation Emission Limit.

The radiation emission for all closed beam RGDs shall not exceed a dose rate of 0.5 mrem

(0.005 mSv) in one hour at five centimeters outside any accessible surface.

8.6.5

Security Screening Units.

During operation and generation of radiation, security screening units shall require operator

presence at the control panel and shall permit surveillance of openings and doors.

A.

During an exposure or preset succession of exposures of one-half second or longer,

means shall be provided to terminate the exposure or preset succession of exposures at

any time.

B.

During an exposure or preset succession of exposures of less than one-half second,

means shall be provided to permit completion of the exposure in progress, but shall allow

the operator to prevent or terminate additional exposures.

8.7

Additional Requirements for Open Beam RGDs.

In addition to the requirements in 8.3, 8.4, and 8.5, the following requirements apply to all open

beam RGDs not otherwise addressed in this Part.

8.7.1

Safety Devices.

A.

The registrant shall document their justification of the use of open-beam instead of

closed-beam systems.

B.

If the registrant needs to use an open-beam system, the registrant shall require a safety

device which prevents the entry of any portion of the operator’s body into the path of the

primary beam or which causes the primary beam to be shut off upon entry into its path.

C.

If the registrant’s use of the open-beam RGD does not permit the use of a safety device

to prevent direct body exposure, the registrant shall maintain a written record of a

description of the various safety devices that have been evaluated and document why

these devices cannot be used. These records shall be available onsite for inspection.

D.

In lieu of the safety device described in 8.7.1.B, the registrant shall employ alternative

methods (such as policies and procedures) to minimize the possibility of unnecessary

exposure. These alternative methods shall be documented. The documentation shall

include information about the absence of safety devices. This documentation shall be

available for inspection as long as these methods are employed, plus an additional 5

years.

E.

For portable open-beam RGDs that are manufactured to be used hand-held, or

potentially used as a hand-held, without such safety devices, the requirements of 8.7.1

may be met by complying with all the requirements in 8.8.

8.7.2

X-ray On Status.

For open beam equipment, RGDs shall be provided with a readily discernible and active

indication of:

A.

X-ray tube “on-off” status located near the radiation source housing. The warning lights

as required by 8.4.1.B can meet this requirement if the warning lights are readily

discernible and viewable by anyone near the primary beam; or

B.

Shutter “open-closed” status located at the control panel and near each beam port on the

radiation source housing, if the primary beam is controlled with a shutter. The shutter

status device shall be clearly labeled as to the meaning of the status device (i.e., whether

the shutter is open or closed). The status light at the control panel can meet the

requirement for the status light at the beam port if the status light at the control panel is

readily discernible and viewable by anyone near the primary beam; and

C.

The x-ray tube “on-off” status indicator and the shutter “open-closed” status indicators

shall be of a fail-safe design.

8.7.3

Labeling.

Each unit will be labeled at or near the x-ray exit beam port to identify the location of the beam

with the words, “CAUTION - X-RAY BEAM”, “CAUTION - HIGH INTENSITY X-RAY BEAM”, or

words having a similar intent.

8.7.4

Beam Ports.

Unused beam ports on radiation source housings shall be secured in the closed position in a

manner which will prevent unintentional opening.

8.7.5

Shutters.

On open-beam RGD configurations that are designed to accommodate interchangeable

components, each beam port on the radiation source housing shall be equipped with a shutter

that cannot be opened unless a collimator or a component coupling has been connected to the

beam port.

8.7.6

Radiation Emission Limits.

The local components of an open-beam RGD shall be located and arranged and shall include

sufficient shielding or access control such that no radiation emissions exist (exclusive of the

primary beam) in any area surrounding the local component group which could result in a dose to

an individual present therein in excess of the dose limits as outlined in Part 4, Section 4.14 of

these regulations. These emissions shall be met at any specified tube rating.

8.7.7

Primary Beam Attenuation.

In cases where the primary x-ray beam is not intercepted by the detector device under all

conditions of operation, protective measures shall be provided, such as auxiliary shielding or

administrative procedures, to avoid exposure to any individual from the transmitted primary x-ray

beam.

8.7.8

Operator Attendance.

The operator shall be in immediate attendance at all times when the equipment is in operation

except when the area is locked or the equipment is secured to protect against unauthorized or

accidental entry.

8.7.9

Controlling Access.

A.

If the RGD is not in a restricted area as defined in Part 1 of these regulations, the

operator shall be able to control access to the RGD at all times during operation.

B.

If the RGD is not in a restricted area and the RGD is capable of creating a radiation area

or a high radiation area as defined in Part 1 of these regulations, the operator shall be

able to control access to the RGD at all times during operation, and:

1.

Radiation areas shall be conspicuously identified. The radiation source shall be

within a conspicuous perimeter (e.g., rope, tape, or other barrier) that identifies

the area in which the dose equivalent rate exceeds 5 mrem (0.05 mSv) per hour.

The area described by the temporary barricade shall be suitably posted with

“CAUTION - RADIATION AREA” signs. The operator shall ensure that no one is

inside or enters the radiation area during operation of the RGD;

2.

High radiation areas shall be conspicuously identified. The radiation source shall

be within a conspicuous perimeter (e.g., rope, tape, or other barrier) that

identifies the area in which the dose equivalent rate exceeds 1 mSv (100 mrem)

per hour. The area described by the temporary barricade shall be suitably posted

with “CAUTION - HIGH RADIATION AREA” signs. The operator shall ensure that

no one is inside or enters the high radiation area during operation of the RGD;

3.

The operator shall perform a visual check of the controlled area to ensure it is

free of all unauthorized personnel immediately prior to activating or exposing the

radiation source;

4.

Surveillance of the exposure area shall be maintained during operation, either by

visual or by other reliable means to ensure that no person enters the area;

5.

Excluding hand-held x-ray systems, when approaching the radiation source,

following the conclusion of an exposure, the operator shall use a suitable

calibrated and operable radiation detection instrument to verify that the x-ray tube

has been de-energized;

6.

A personal alarming dose rate meter may be worn to approach the work area if

the device is appropriately designed and calibrated for the type of x-ray emitted

(i.e., pulse or continuous), set at an appropriate level to detect the presence of

the source, for example 2 mrem (0.02 mSv) per hour, and has been source-

checked prior to use. The radiation in the work area must be reasonably uniform

so that the device responds to radiation exposure to any part of the body. It may

not be used to measure radiation levels, nor may it be used to indicate the

presence of the source for potential non-uniform exposure, such as may occur

during machine maintenance or work in a RGD target area;

7.

Measurement of radiation levels for a radiation survey shall be performed using

an appropriate calibrated radiation survey meter. A radiation survey meter shall

also be used when there is potential for non-uniform exposure to personnel, such

as may occur during machine maintenance or work in a RGD target area;

8.

During the initial exposure, the radiation levels shall be measured around the

perimeter of the controlled area. The perimeter shall be adjusted accordingly to

meet the access control requirement for radiation areas or high radiation areas;

and;

9.

The survey around the perimeter shall be made for each new operating condition

and the perimeter adjusted accordingly. The area of operation shall be monitored

periodically if radiation levels are variable.

8.7.10 Instruction and Training.

In addition to the requirements in 8.4.11, no individual shall be permitted to operate or maintain

an open-beam RGD unless such individual has received specific and detailed instruction in and

demonstrated competence as to:

A.

Sources and magnitude of common radiation exposure;

B.

Units of radiation measurement;

C.

Radiation protection concepts of time, distance, shielding, and ALARA;

D.

Procedures and rights of a declared pregnancy;

E.

Regulatory requirements and area postings;

F.

Worker, embryo/fetus, and public dose limits;

G.

Proper use of survey instruments and dosimetry; and

H.

The policies and procedures required by 8.7.1.

8.8

Additional Requirements for Open-beam, Hand-held RGDs.

In addition to the applicable requirements in 8.3, 8.4, 8.5 and 8.7, the following requirements in

this Section apply to open-beam, RGDs intended or designed to be hand-held during operation.

8.8.1

Procedures.

All registrants possessing open-beam, hand-held RGDs shall have available for review by the

Department, operating policies and procedures that contain measures to insure that:

A.

Radiation protection is provided equivalent to that afforded in Part 4, Section 4.14 of

these regulations (Dose Limits for Individual Members of the Public);

B.

Radiation protection is provided equivalent to that afforded in 8.7.7 (Primary Beam

Attenuation);

C.

The operator will not hold the sample during operation of the RGD and that the operator’s

hands will not approach the primary beam;

D.

The operator will not aim the primary beam at him/herself or at any individual during

operation of the RGD; and

E.

Operator radiation exposure is as low as reasonably achievable (ALARA), for example,

by use of ancillary equipment that will reduce exposure.

8.8.2

Training.

In addition to the training requirements of 8.4.11 and 8.7.10 above, the registrant shall provide

training for all users and operators on the subjects in section 8.8.1. Records shall be maintained

of all user and operator training.

8.8.3

Radiation Emission Limit.

For hand-held RGDs, the limits of 8.4.3.A and 8.4.4, excluding the primary beam, shall be met if

the radiation emission at any accessible surface of the RGD does not exceed 2.5 mrem (0.025

mSv) per hour at 5 centimeters.

8.8.4

Extremity Monitoring.

For the purposes of the requirements in 8.5.3 (extremity monitoring), operators of hand-held

RGDs shall be considered as working near the primary beam and shall be required to wear

extremity dosimetry, unless explicitly exempted by the Department.

8.8.5

Excluding hand-held XRF units, and other units exempted in writing by the Department, the

operator of a hand-held RGD shall be protected from scatter radiation by material of not less than

0.25 millimeter lead equivalent unless the RSO and Department determine that no added

protection is needed for the device use and model.

8.9

Shielded Room RGDs.

For RGDs that do not meet the limits of Part 4, Section 4.14, the RGD can be maintained inside a

shielded room such that the exterior of the room meets the limits of Part 4, Section 4.14 of these

regulations when the RGD is activated. RGDs in a shielded room shall be required to meet only

the requirements of 8.3, 8.4, and 8.5 and the following:

8.9.1

Posting.

The door to the room containing the RGD shall be posted “CAUTION – RADIATION AREA”, or

“CAUTION – HIGH RADIATION AREA”, or “GRAVE DANGER – VERY HIGH RADIATION

AREA”, as required by Part 4 of these regulations.

8.9.2

Entrance Interlocks.

All entrances into the shielded room shall be provided with interlocks. After an interlock has been

interrupted, broken, or tripped, it shall be possible to cause x-rays to be produced again only from

the control panel. Interlocks shall not be used to shut off the x-ray equipment except in an

emergency or during testing.

8.9.3

Entrance Warning Devices.

All entrances into the shielded room shall be provided with a conspicuously visible warning

device, which need not be flashing or rotating but which operates only when radiation is being

produced. The warning device shall be labeled in accordance with H.6a.

8.9.4

Room Warning Lights.

The interior of the shielded room shall be provided with flashing or rotating warning lights that

operate when, and only when, radiation is being produced. These lights shall be positioned so

that they can be observed from any position or orientation within the room. The lights shall be

posted indicating the meaning of the warning signal and instructions on what to do; the posting

shall be legible, conspicuous, and accessible to view.

8.9.5

Audible Room Warning Device.

An audible warning signal within the room shall be actuated for at least ten (10) seconds

immediately prior to the first initiation of radiation after the closing of any opening that can admit

personnel. The registrant shall post the meaning of the warning signal and instructions on what to

do; the posting shall be legible, conspicuous, and accessible to view.

8.9.6

Emergency Shut-off.

If dose rates exceed the High Radiation Area limits as defined in Part 1 of these regulations,

emergency shut-off switches shall be located within the high radiation areas so as to be

accessible to individuals therein within 10 seconds. These switches and their mode of operation

shall be identified by a conspicuously posted sign adjacent to the switch. The emergency shut-off

switches shall include a manual reset that must be reset at the switch before x-rays can again be

produced from the control panel. After an emergency shut-off switch has been activated, it shall

be possible to produce x-rays again only from the control panel.

8.9.7

Separate Electrical Systems.

The interlock system and the emergency shut-off system shall be separate electrical and/or

mechanical systems.

8.9.8

Exit from Shielded Room.

A person within the room housing a RGD shall be able to exit at all times.

8.9.9

Entry into the Shielded Room.

A.

After each exposure and before entry of any personnel, a survey shall be performed upon

entry to the shielded room to determine that the RGD is no longer producing radiation.

B.

Personnel devices providing an audible signal when activated by radiation will be

acceptable for the survey requirement of 8.9.9.A.

1.

Proper operation of the audible detection device shall be checked daily and a

record maintained of this check.

2.

The audible device shall be designed so as to clearly indicate entry into a 2

mrem (0.02 mSv) per hour or greater radiation field.

3.

All personnel working with the RGD shall be provided with such a device.

C.

Stationary area monitors providing an audible signal when activated by radiation will be

acceptable for the survey requirement of 8.9.9.A.

1.

Proper operation of the stationary detection device shall be checked daily and a

record maintained of this check.

2.

The stationary device shall be designed so as to clearly indicate entry into a 2

mrem (0.02 mSv) per hour or greater radiation field.

3.

Stationary area monitors shall be calibrated annually to determine that the

audible signal operates at a 2 mrem (0.02 mSv) per hour radiation field.

8.9.10 Personnel Monitoring.

All personnel associated with the x-ray equipment shall be provided with personnel monitoring

devices that shall be calibrated for the x-ray energies being utilized. Records of personnel

exposure shall be maintained.

8.9.11 Training.

No registrant shall permit any individual to operate a RGD in a shielded room until such individual

has received a copy of, instruction in, and demonstrated an understanding of, operating and

emergency procedures for the unit and competence in its use. Records shall be maintained of all

operator training.

8.9.12 Control Panel Security.

The equipment control panel shall be provided with a locking device to prevent unauthorized use.

Such locking device shall, when locked, prevent the production of radiation by the equipment.

8.9.13 Malfunctions.

If a safety or warning device malfunctions, the control panel shall be locked in the “off” position.

The control panel shall not be used, except as may be necessary for repair or replacement of the

malfunctioning safety or warning device, until the safety or warning device is functioning properly.

8.10

Reserved.

8.11

RGDs Used in Human Body Security Screening or Vehicle Screening for Public Protection.

The requirements in this section are in addition to the General Requirements in 8.4, 8.5, and 8.6.

A person must request Department approval for a RGD to be used for Human Body Security

Screening or Vehicle Screening involving intended exposure of human occupants to the primary

beam for public protection purposes. Such persons shall submit the appropriate form or submit in

writing the following information to the Department for evaluation and approval, and demonstrate

how the dose limits in 8.11 will be met:

8.11.1 Efficacy Evaluation.

An evaluation of all known alternate methods that could achieve the goals of the security

screening program, and why these methods will not be used in preference to the proposed

approach utilizing ionizing radiation.

8.11.2 Equipment Evaluation.

RGDs used for human body security screening shall be evaluated every 12 months by a Qualified

Inspector for radiation dose and optimization of image quality. Evaluation of optimization of image

quality shall be done in accord with the system manufacturer’s specifications, recommendations,

and quality assurance procedures or, in the absence of manufacturer provided information on

image quality, the recommendations of a nationally recognized organization or Qualified

Inspector.

8.11.3 Dose Limits for General-Use Systems.

For general-use screening systems, where the system is used without regard to the number of

individuals scanned or number of scans per individual in a year, an effective dose for a single

complete screening shall be limited to 25 µrem (0.25 µSv).

8.11.4 Dose Limits for Limited-Use Systems.

For limited-use screening systems, where the system is capable of operation greater than 25

µrem (0.25 µSv) per screening, and is used with discretion, the effective dose per screening shall

be less than or equal to 1 mrem (0.01 mSv).

8.11.5 Dose Limits for Repeat Security Screenings.

Individuals subject to repeat security screening at a single venue shall not receive an effective

dose greater than 25 mrem (0.25 mSv) in any one year at the registrant’s facility.

8.11.6 Requirements for vehicle or container screening systems.

A.

When the procedures for operation of a RGD used for security screening of vehicles

includes knowingly exposing human occupants to the primary beam when screening

vehicles, structures or containers, the system shall be subject to the same requirements

as general-use or limited-use systems as provided in 8.11.1 through 8.11.5.

B.

If the requirements in 8.11.3 through 8.11.5. cannot be met if vehicle occupants are

knowingly exposed to the primary beam of a security screening system, then there shall

be means to assure the occupied portion of the vehicle is outside of the scan area while

the primary beam is emitted or procedures shall be established and implemented to

assure that no occupants are present in the vehicle during screening.

C.

The effective dose to an individual for a single inadvertent exposure to the primary beam

shall not exceed 500 mrem (5 mSv) and should not exceed 100 mrem (1 mSv). The

reliability of the procedure used to assure that there are no occupants of a vehicle to be

scanned shall be commensurate with the potential severity of an inadvertent exposure. If

the 500 mrem (5 mSv) limit cannot be assured, a pre-screening with a mode or system

which can meet the limits in 8.11.3 through 8.11.6 shall be used to verify there are no

occupants in the vehicle being examined.