RADIATION CONTROL - STANDARDS FOR PROTECTION AGAINST RADIATION

ColoradoRegulations

Ask Donna

How this section applies to your facts.

Code of Colorado Regulations › 1000 Department of Public Health and Environment › 1007 Hazardous Materials and Waste Management Division › 6 CCR 1007-1 Part 04

This text was captured on Sep 30, 2026. It is a snapshot, not a live feed, so check the official code before relying on it.

Text

_________________________________________________________________________

Adopted by the Board of Health on October 18, 2023; effective December 15, 2023.

PART 4:

STANDARDS FOR PROTECTION AGAINST RADIATION

STANDARDS FOR PROTECTION AGAINST RADIATION

4.1

Purpose and Scope

4.1.1

Authority.

4.1.1.1 Rules and regulations set forth herein are adopted pursuant to the provisions of Sections

25-1-108, 25-1.5-101(1)(k) and (1)(l), and 25-11-104, CRS.

4.1.2

Basis and Purpose.

4.1.2.1 A statement of basis and purpose of these regulations is incorporated as part of these

regulations; a copy may be obtained from the Department.

4.1.3

Scope.

4.1.3.1 This Part 4 establishes standards for protection against ionizing radiation resulting from

activities conducted pursuant to licenses or registrations issued by the Department.

4.1.3.2 The requirements of Part 4 are designed to control the receipt, possession, use, transfer,

and disposal of sources of radiation by any licensee or registrant so the total dose to an

individual, including doses resulting from all sources of radiation other than background

radiation, does not exceed the standards for protection against radiation prescribed in

Part 4. However, nothing in Part 4 shall be construed as limiting actions that may be

necessary to protect health and safety.

4.1.4

Applicability.

4.1.4.1 Except as specifically provided in other parts of these regulations, Part 4 applies to

persons licensed or registered by the Department to receive, possess, use, transfer, or

dispose of sources of radiation. The limits in Part 4 do not apply to doses due to

background radiation, to exposure of patients to radiation for the purpose of medical

diagnosis or therapy, to exposure from individuals administered radioactive material and

released in accordance with 7.26, or to exposure from voluntary participation in medical

research programs.

Hazardous Materials and Waste Management

2

4.1.5

Published Material Incorporated by Reference.

4.1.5.1 Throughout this Part 4, federal regulations, state regulations, and standards or guidelines

of outside organizations have been adopted and incorporated by reference. Unless a

prior version of the incorporated material is otherwise specifically indicated, the materials

incorporated by reference cited herein include only those versions that were in effect as

of the most recent effective date of this Part 4 (December 2023), and not later

amendments or editions of the incorporated material.

4.1.5.2 Materials incorporated by reference are available for public inspection, and copies

(including certified copies) can be obtained at reasonable cost, during normal business

hours from the Colorado Department of Public Health and Environment, Hazardous

Materials and Waste Management Division, 4300 Cherry Creek Drive South, Denver,

Colorado 80246. Additionally, https://www.colorado.gov/hm/radregs identifies where the

incorporated material is available to the public on the internet at no cost. Due to copyright

restrictions, certain materials incorporated in this Part are available for public inspection

at the state publications depository and distribution center.

4.1.5.3 Availability from Source Agencies or Organizations.

(1)

All federal agency regulations incorporated by reference herein are available at

no cost in the online edition of the Code of Federal Regulations (CFR) hosted by

the U.S. Government Publishing Office, online at

https://www.govinfo.gov/app/collection/cfr/.

(2)

All state regulations incorporated by reference herein are available at no cost in

the online edition of the Code of Colorado Regulations (CCR) hosted by the

Colorado Secretary of State’s Office, online at

https://www.sos.state.co.us/CCR/Welcome.do.

4.2

Definitions.

4.2.1

Reserved.

4.3

Implementation.

4.3.1

Any existing license or registration condition that is more restrictive than Part 4 remains in

force until there is an amendment or renewal of the license or registration.

4.4

Reserved.

RADIATION PROTECTION PROGRAMS

4.5

Radiation Protection Programs.

4.5.1

Each licensee or registrant shall develop, document, and implement a radiation protection

program sufficient to ensure compliance with the provisions of Part 4. See 4.41 for recordkeeping

requirements relating to these programs.

4.5.2

The licensee or registrant shall use, to the extent practical, procedures and engineering controls

based upon sound radiation protection principles to achieve occupational doses and doses to

members of the public that are as low as is reasonably achievable (ALARA).

4.5.3

The licensee or registrant shall, at intervals not to exceed 12 months, review the radiation

protection program content and implementation.

Hazardous Materials and Waste Management

3

4.5.4

To implement the ALARA requirements of 4.5.2 and notwithstanding the requirements in 4.14 of

this part, a constraint on air emissions of radioactive material to the environment, excluding

radon-222 and its decay products, shall be established by licensees, such that the individual

member of the public likely to receive the highest dose will not be expected to receive a total

effective dose equivalent in excess of 0.1 millisievert (10 mrem) per year from these emissions. If

a licensee subject to this requirement exceeds this dose constraint, the licensee shall report such

event as provided in 4.53.2 and promptly take appropriate corrective action to ensure against

recurrence.

OCCUPATIONAL DOSE LIMITS

4.6

Occupational Dose Limits for Adults.

4.6.1

The licensee or registrant shall control the occupational dose to individual adults, except for

planned special exposures pursuant to 4.11, to the following dose limits:

4.6.1.1 An annual limit, which is the more limiting of:

(1)

The total effective dose equivalent being equal to 0.05 Sv (5 rem); or

(2)

The sum of the deep dose equivalent and the committed dose equivalent to any

individual organ or tissue other than the lens of the eye being equal to 0.5 Sv (50

rem).

4.6.1.2 The annual limits to the lens of the eye, to the skin of the whole body, and to the skin of

the extremities, which are:

(1)

A lens dose equivalent of 0.15 Sv (15 rem), and

(2)

A shallow dose equivalent of 0.5 Sv (50 rem) to the skin of the whole body or to

the skin of any extremity.

4.6.2

Doses received in excess of the annual limits, including doses received during accidents,

emergencies, and planned special exposures, shall be subtracted from the limits for planned

special exposures that the individual may receive during the current year and during the

individual's lifetime. See 4.11.5.1 and 4.11.5.2.

4.6.3

Assigned dose equivalent.

4.6.3.1 When the external exposure is determined by measurement with an external personal

monitoring device, the deep-dose equivalent must be used in place of the effective dose

equivalent, unless the effective dose equivalent is determined by a dosimetry method

approved by the NRC.

4.6.3.2 The assigned deep dose equivalent must be for the part of the body receiving the highest

exposure.

4.6.3.3 The assigned shallow dose equivalent must be the dose averaged over the contiguous

10 square centimeters of skin receiving the highest exposure.

4.6.3.4 The deep-dose equivalent, lens dose equivalent, and shallow dose equivalent may be

assessed from surveys or other radiation measurements for the purpose of

demonstrating compliance with the occupational dose limits, if the individual monitoring

device was not in the region of highest potential exposure, or the results of individual

monitoring are unavailable.

Hazardous Materials and Waste Management

4

4.6.3.5 In the case of occupational exposures to x-rays with accelerating voltages of less than

145 kVp and where the worker utilizes lead garment protection, the registrant may

calculate the assigned dose equivalent using methods discussed in NRC Regulatory

Information Summary (RIS) 2002-061, other methods as specifically approved by the

Department, or by use of the following equation:

1 NRC RIS 2002-06, Evaluating Occupational Dose For Individuals Exposed To NRC-licensed Material And Medical X-Rays, April

16, 2002 (http://www.nrc.gov/; ML021000613).

(1)

Lead apron and no thyroid collar:

assigned deep dose equivalent = 0.06 x (collar dose – waist dose) + waist dose

(2)

Lead apron and thyroid collar:

assigned deep dose equivalent = 0.02 x (collar dose – waist dose) + waist dose

4.6.4

Derived air concentration (DAC) and annual limit on intake (ALI) values are presented in Table

4B1 of Appendix 4B and may be used to determine the individual's dose and to demonstrate

compliance with the occupational dose limits. See 4.46.

4.6.5

Notwithstanding the annual dose limits, the licensee shall limit the soluble uranium intake by an

individual to 10 milligrams in a week in consideration of chemical toxicity. See footnote 3 of

Appendix 4B.

4.6.6

The licensee or registrant shall reduce the dose that an individual may be allowed to receive in

the current year by the amount of occupational dose received while employed by any other

person. See 4.10.3.1 and 4.10.5.

4.7

Compliance with Requirements for Summation of External and Internal Doses.

4.7.1

If the licensee or registrant is required to monitor pursuant to both 4.18.1 and 4.18.2, the licensee

or registrant shall demonstrate compliance with the dose limits by summing external and internal

doses. If the licensee or registrant is required to monitor only pursuant to 4.18.1 or only pursuant

to 4.18.2, then summation is not required to demonstrate compliance with the dose limits. The

licensee or registrant may demonstrate compliance with the requirements for summation of

external and internal doses pursuant to 4.7.2, 4.7.3 and 4.7.4. The dose equivalents for the lens

of the eye, the skin, and the extremities are not included in the summation, but are subject to

separate limits.

4.7.2

Intake by Inhalation.

If the only intake of radionuclides is by inhalation, the total effective dose equivalent limit is not

exceeded if the sum of the deep dose equivalent divided by the total effective dose equivalent

limit, and one of the following, does not exceed unity:

4.7.2.1 The sum of the fractions of the inhalation ALI for each radionuclide, or

4.7.2.2 The total number of derived air concentration-hours (DAC-hours) for all radionuclides

divided by 2,000, or

Hazardous Materials and Waste Management

5

4.7.2.3 The sum of the calculated committed effective dose equivalents to all significantly

irradiated organs or tissues (T) calculated from bioassay data using appropriate biological

models and expressed as a fraction of the annual limit. For purposes of this requirement,

an organ or tissue is deemed to be significantly irradiated if, for that organ or tissue, the

product of the weighting factors, WT, and the committed dose equivalent, HT, 50, per unit

intake is greater than 10 percent of the maximum weighted value of H50, that is, WT x HT,

50, per unit intake for any organ or tissue.

4.7.3

Intake by Oral Ingestion.

4.7.3.1 If the occupationally exposed individual also receives an intake of radionuclides by oral

ingestion greater than 10 percent of the applicable oral ALI, the licensee or registrant

shall account for this intake and include it in demonstrating compliance with the limits.

4.7.4

Intake through Wounds or Absorption through Skin.

4.7.4.1 The licensee or registrant shall evaluate and, to the extent practical, account for intakes

through wounds or skin absorption. The intake through intact skin has been included in

the calculation of DAC for hydrogen-3 and does not need to be evaluated or accounted

for pursuant to 4.7.4.

4.8

Determination of External Dose from Airborne Radioactive Material.

4.8.1

Licensees or registrants shall, when determining the dose from airborne radioactive material,

include the contribution to the deep dose equivalent, lens dose equivalent, and shallow dose

equivalent from external exposure to the radioactive cloud. See Appendix 4B, footnotes 1 and 2.

4.8.2

Airborne radioactivity measurements and DAC values shall not be used as the primary means to

assess the deep dose equivalent when the airborne radioactive material includes radionuclides

other than noble gases or if the cloud of airborne radioactive material is not relatively uniform.

The determination of the deep dose equivalent to an individual shall be based upon

measurements using instruments or individual monitoring devices.

4.9

Determination of Internal Exposure.

4.9.1

For purposes of assessing dose used to determine compliance with occupational dose equivalent

limits, the licensee or registrant shall, when required pursuant to 4.18, take suitable and timely

measurements of:

4.9.1.1 Concentrations of radioactive materials in air in work areas; or

4.9.1.2 Quantities of radionuclides in the body; or

4.9.1.3 Quantities of radionuclides excreted from the body; or

4.9.1.4 Combinations of 4.9.1.1, 4.9.1.2 and 4.9.1.3.

4.9.2

Unless respiratory protective equipment is used, as provided in 4.24, or the assessment of intake

is based on bioassays, the licensee or registrant shall assume that an individual inhales

radioactive material at the airborne concentration in which the individual is present.

4.9.3

When specific information on the physical and biochemical properties of the radionuclides taken

into the body or the behavior of the material in an individual is known, the licensee or registrant

may:

Hazardous Materials and Waste Management

6

4.9.3.1 Use that information to calculate the committed effective dose equivalent, and, if used,

the licensee or registrant shall document that information in the individual's record; and

4.9.3.2 Upon prior approval of the Department, adjust the DAC or ALI values to reflect the actual

physical and chemical characteristics of airborne radioactive material, for example,

aerosol size distribution or density; and

4.9.3.3 Separately assess the contribution of fractional intakes of Class D, W, or Y compounds of

a given radionuclide to the committed effective dose equivalent. See Appendix 4B.

4.9.4

If the licensee or registrant chooses to assess intakes of Class Y material using the

measurements given in 4.9.1.2 or 4.9.1.3, the licensee or registrant may delay the recording and

reporting of the assessments for periods up to 7 months, unless otherwise required by 4.52 or

4.53. This delay permits the licensee or registrant to make additional measurements basic to the

assessments.

4.9.5

If the identity and concentration of each radionuclide in a mixture are known, the fraction of the

DAC applicable to the mixture for use in calculating DAC-hours shall be either:

4.9.5.1 The sum of the ratios of the concentration to the appropriate DAC value, that is, D, W, or

Y, from Appendix 4B for each radionuclide in the mixture; or

4.9.5.2 The ratio of the total concentration for all radionuclides in the mixture to the most

restrictive DAC value for any radionuclide in the mixture.

4.9.6

If the identity of each radionuclide in a mixture is known, but the concentration of one or more of

the radionuclides in the mixture is not known, the DAC for the mixture shall be the most restrictive

DAC of any radionuclide in the mixture.

4.9.7

When a mixture of radionuclides in air exists, a licensee or registrant may disregard certain

radionuclides in the mixture if:

4.9.7.1 The licensee or registrant uses the total activity of the mixture in demonstrating

compliance with the dose limits in 4.6 and in complying with the monitoring requirements

in 4.18.2; and

4.9.7.2 The concentration of any radionuclide disregarded is less than 10 percent of its DAC; and

4.9.7.3 The sum of these percentages for all of the radionuclides disregarded in the mixture does

not exceed 30 percent.

4.9.8

When determining the committed effective dose equivalent, the following information may be

considered:

4.9.8.1 In order to calculate the committed effective dose equivalent, the licensee or registrant

may assume that the inhalation of one ALI, or an exposure of 2,000 DAC-hours, results in

a committed effective dose equivalent of 0.05 Sv (5 rem) for radionuclides that have their

ALIs or DACs based on the committed effective dose equivalent.

Hazardous Materials and Waste Management

7

4.9.8.2 For an ALI and the associated DAC determined by the nonstochastic organ dose limit of

0.5 Sv (50 rem), the intake of radionuclides that would result in a committed effective

dose equivalent of 0.05 Sv (5 rem), that is, the stochastic ALI, is listed in parentheses in

Table 4B1 of Appendix 4B. The licensee or registrant may, as a simplifying assumption,

use the stochastic ALI to determine committed effective dose equivalent. However, if the

licensee or registrant uses the stochastic ALI, the licensee or registrant shall also

demonstrate that the limit in 4.6.1.1.(2) is met.

4.10

Determination of Prior Occupational Dose.

4.10.1 For each individual who is likely to receive, in a year, an occupational dose requiring monitoring

pursuant to 4.18, the licensee or registrant shall determine the occupational radiation dose

received during the current year.

4.10.2 Prior to permitting an individual to participate in a planned special exposure, the licensee or

registrant shall determine:

4.10.2.1

The internal and external doses from all previous planned special exposures; and

4.10.2.2

All doses in excess of the limits, including doses received during accidents and

emergencies, received during the lifetime of the individual.

4.10.3 In complying with the requirements of 4.10.1 or 4.10.2, a licensee or registrant may:

4.10.3.1

Accept, as a record of the occupational dose that the individual received during

the current year, a written signed statement from the individual, or from the individual's

most recent employer for work involving radiation exposure, that discloses the nature and

the amount of any occupational dose that the individual received during the current year;

and

4.10.3.2

Accept, as the record of cumulative radiation dose, an up-to-date Department

Form R-16, Cumulative Occupational Exposure History, or equivalent, signed by the

individual and countersigned by an appropriate official of the most recent employer for

work involving radiation exposure, or the individual's current employer, if the individual is

not employed by the licensee or registrant; and

4.10.3.3

Obtain reports of the individual's dose equivalent from the most recent employer

for work involving radiation exposure, or the individual's current employer, if the individual

is not employed by the licensee or registrant, by telephone, telegram, facsimile, or letter.

The licensee or registrant shall request a written verification of the dose data if the

authenticity of the transmitted report cannot be established.

4.10.4 Record of Exposure History.

4.10.4.1

The licensee or registrant shall record the exposure history, as required by 4.10.1

or 4.10.2, on Department Form R-16, or other clear and legible record, of all the

information required on that form. The form or record shall show each period in which the

individual received occupational exposure to radiation or radioactive material and shall be

signed by the individual who received the exposure. For each period for which the

licensee or registrant obtains reports, the licensee or registrant shall use the dose shown

in the report in preparing Department Form R-16 or equivalent. For any period in which

the licensee or registrant does not obtain a report, the licensee or registrant shall place a

notation on Department Form R-16 or equivalent indicating the periods of time for which

data are not available.

Hazardous Materials and Waste Management

8

4.10.4.2

Licensees or registrants are not required to reevaluate the separate external

dose equivalents and internal committed dose equivalents or intakes of radionuclides

assessed pursuant to the Regulations in Part 4 in effect before January 1, 1994. Further,

occupational exposure histories obtained and recorded before January 1, 1994 on

Department Form R-16 or equivalent, would not have included effective dose equivalent,

but may be used in the absence of specific information on the intake of radionuclides by

the individual.

4.10.5 If the licensee or registrant is unable to obtain a complete record of an individual's current and

previously accumulated occupational dose, the licensee or registrant shall assume:

4.10.5.1

In establishing administrative controls pursuant to 4.6.6 for the current year, that

the allowable dose limit for the individual is reduced by 12.5 mSv (1.25 rem) for each

quarter for which records were unavailable and the individual was engaged in activities

that could have resulted in occupational radiation exposure; and

4.10.5.2

That the individual is not available for planned special exposures.

4.10.6 The licensee or registrant shall retain the records on Department Form R-16 or equivalent until

the Department terminates each pertinent license or registration requiring this record. The

licensee or registrant shall retain records used in preparing Department Form R-16 or equivalent

for 3 years after the record is made.

4.11

Planned Special Exposures.

A licensee or registrant may authorize an adult worker to receive doses in addition to and

accounted for separately from the doses received under the limits specified in 4.6 provided that

each of the following conditions in 4.11.1 through 4.11.7 is satisfied:

4.11.1 The licensee or registrant authorizes a planned special exposure only in an exceptional situation

when alternatives that might avoid the dose estimated to result from the planned special

exposure are unavailable or impractical.

4.11.2 The licensee or registrant, and employer if the employer is not the licensee or registrant,

specifically authorizes the planned special exposure, in writing, before the exposure occurs.

4.11.3 Before a planned special exposure, the licensee or registrant ensures that each individual

involved is:

4.11.3.1

Informed of the purpose of the planned operation; and

4.11.3.2

Informed of the estimated doses and associated potential risks and specific

radiation levels or other conditions that might be involved in performing the task; and

4.11.3.3

Instructed in the measures to be taken to keep the dose ALARA considering

other risks that may be present.

4.11.4 Prior to permitting an individual to participate in a planned special exposure, the licensee or

registrant ascertains prior doses as required by 4.10.2 during the lifetime of the individual for each

individual involved.

4.11.5 Subject to 4.6.2, the licensee or registrant shall not authorize a planned special exposure that

would cause an individual to receive a dose from all planned special exposures and all doses in

excess of the limits to exceed:

Hazardous Materials and Waste Management

9

4.11.5.1

The numerical values of any of the dose limits in 4.6.1 in any year; and

4.11.5.2

Five times the annual dose limits in 4.6.1 during the individual's lifetime.

4.11.6 The licensee or registrant maintains records of the conduct of a planned special exposure in

accordance with 4.45 and submits a written report in accordance with 4.54.

4.11.7 The licensee or registrant records the best estimate of the dose resulting from the planned

special exposure in the individual's record and informs the individual, in writing, of the dose within

30 days from the date of the planned special exposure. The dose from planned special exposures

shall not be considered in controlling future occupational dose of the individual pursuant to 4.6.1

but shall be included in evaluations required by 4.11.4 and 4.11.5.

4.12

Occupational Dose Limits for Minors.

The annual occupational dose limits for minors are 10 percent of the annual occupational dose

limits specified for adult workers in 4.6.

4.13

Dose Equivalent to an Embryo/Fetus.

4.13.1 The licensee or registrant shall ensure that the dose equivalent to an embryo/fetus during the

entire pregnancy, due to the occupational exposure of a declared pregnant woman, does not

exceed 5 mSv (0.5 rem). See 4.46 for recordkeeping requirements.

4.13.2 The licensee or registrant shall make efforts to avoid substantial variation2 above a uniform

monthly exposure rate to a declared pregnant woman so as to satisfy the limit in 4.13.1.

2 The National Council on Radiation Protection and Measurements recommended in NCRP Report No. 91 “Recommendations on

Limits for Exposure to Ionizing Radiation” (June 1, 1987) that no more than 0.5 mSv (0.05 rem) to the embryo/fetus be received in

any one month.

4.13.3 The dose equivalent to an embryo/fetus is the sum of:

4.13.3.1

The deep dose equivalent to the declared pregnant woman; and

4.13.3.2

The dose equivalent to the embryo/fetus resulting from radionuclides in the

embryo/fetus and radionuclides in the declared pregnant woman.

4.13.4 If the dose equivalent to the embryo/fetus is found to have exceeded 5 mSv (0.5 rem), or is within

0.5 mSv (0.05 rem) of this dose, by the time the woman declares the pregnancy to the licensee or

registrant, the licensee or registrant shall be deemed to be in compliance with 4.13.1 if the

additional dose equivalent to the embryo/fetus does not exceed 0.5 mSv (0.05 rem) during the

remainder of the pregnancy.

RADIATION DOSE LIMITS FOR INDIVIDUAL MEMBERS OF THE PUBLIC

4.14

Dose Limits for Individual Members of the Public.

4.14.1 Each licensee or registrant shall conduct operations so that:

Hazardous Materials and Waste Management

10

4.14.1.1

The total effective dose equivalent to individual members of the public from the

licensed or registered operation does not exceed 1 millisievert (0.1 rem) in a year,

exclusive of the dose contributions from background radiation, from any medical

administration the individual has received, from exposure to individuals administered

radioactive material and released in accordance with 7.26, from voluntary participation in

medical research programs, and from the dose contribution from the licensee's or

registrant's disposal of radioactive material into sanitary sewerage in accordance with

4.35, and

4.14.1.2

The dose in any unrestricted area from external sources, exclusive of the dose

contributions from patients administered radioactive material and released in accordance

with 7.26, does not exceed 0.02 millisievert (0.002 rem) in any one hour.

4.14.2 A licensee may permit visitors to an individual who cannot be released under 7.26 to receive a

radiation dose greater than 1 mSv (0.1 rem) if:

4.14.2.1

The radiation dose received does not exceed 5 mSv (0.5 rem); and

4.14.2.2

The authorized user, as defined in Part 7, has determined before the visit that it

is appropriate.

4.14.3 A licensee, registrant, or an applicant for a license or registration may apply for prior Department

authorization to operate up to an annual dose limit for an individual member of the public of 5

mSv (0.5 rem). This application shall include the following information:

4.14.3.1

Demonstration of the need for and the expected duration of operations in excess

of the limit in 4.14.1; and

4.14.3.2

The licensee's or registrant's program to assess and control dose within the 5

mSv (0.5 rem) annual limit; and

4.14.3.3

The procedures to be followed to maintain the dose ALARA.

4.14.4 In addition to the requirements of Part 4, a licensee or registrant subject to the provisions of the

U.S. Environmental Protection Agency's generally applicable environmental radiation standards

in 40 CFR 190 (July 1, 2004) shall comply with those standards.

4.14.5 The Department may impose additional restrictions on radiation levels in unrestricted areas and

on the total quantity of radionuclides that a licensee or registrant may release in effluents in order

to restrict the collective dose.

4.15

Compliance with Dose Limits for Individual Members of the Public.

4.15.1 The licensee or registrant shall make or cause to be made surveys of radiation levels in

unrestricted areas and radioactive materials in effluents released to unrestricted areas to

demonstrate compliance with the dose limits for individual members of the public in 4.14.

4.15.2 A licensee or registrant shall show compliance with the annual dose limit in 4.14 by:

4.15.2.1

Demonstrating by measurement or calculation that the total effective dose

equivalent to the individual likely to receive the highest dose from the licensed or

registered operation does not exceed the annual dose limit; or

4.15.2.2

Demonstrating that:

Hazardous Materials and Waste Management

11

(1)

The annual average concentrations of radioactive material released in gaseous

and liquid effluents at the boundary of the unrestricted area do not exceed the

values specified in Table 4B2 of Appendix 4B; and

(2)

If an individual were continually present in an unrestricted area, the dose from

external sources would not exceed 0.02 mSv (0.002 rem) in an hour and 0.5 mSv

(0.05 rem) in a year.

4.15.3 Upon approval from the Department, the licensee or registrant may adjust the effluent

concentration values in Appendix 4B, Table 4B2, for members of the public, to take into account

the actual physical and chemical characteristics of the effluents, such as, aerosol size distribution,

solubility, density, radioactive decay equilibrium, and chemical form.

4.15.4 Rooms or areas in which diagnostic x-ray systems are the only source of radiation shall

demonstrate compliance with 4.15.2.1 after construction of a new x-ray facility, after modification

or renovation of an existing x-ray facility, or installation or a new x-ray machine in an existing x-

ray facility when there is a change in primary beam orientation, or a change in primary shielding

due to the modification or renovation of a facility, or where there is a projected increase in the x-

ray workload from that which was used for a prior x-ray shielding design.

4.15.5 Rooms or areas in which only dental intraoral, dental panoramic, mini-c-arm x-ray, or bone

densitometry systems are used, are exempt from the requirements of 4.15.2.1.

TESTING FOR LEAKAGE OR CONTAMINATION OF SEALED SOURCES

4.16

Testing for Leakage or Contamination of Sealed Sources.

4.16.1 The licensee or registrant in possession of any sealed source shall assure that:

4.16.1.1

Each sealed source, except as specified in 4.16.2, is tested for leakage or

contamination and the test results are received before the sealed source is put into use

unless the licensee or registrant has a certificate from the transferor indicating that the

sealed source was tested within 6 months before transfer to the licensee or registrant.

Sources that indicate contamination in excess of 185 Bq (0.005 microcuries) shall not be

put into use.

4.16.1.2

Each sealed source that is not designed to emit alpha particles is tested for

leakage or contamination at intervals not to exceed 6 months or at alternative intervals

approved by the Department, after evaluation of information specified by 3.12.12.2 and

3.12.12.3 of these regulations, an Agreement State, a Licensing State, or the U.S.

Nuclear Regulatory Commission.

4.16.1.3

Each sealed source that is designed to emit alpha particles is tested for leakage

or contamination at intervals not to exceed 3 months or at alternative intervals approved

by the Department, after evaluation of information specified by 3.12.12.2 and 3.12.12.3 of

these regulations, an Agreement State, a Licensing State, or the U.S. Nuclear Regulatory

Commission.

4.16.1.4

For each sealed source that is required to be tested for leakage or

contamination, at any other time there is reason to suspect that the sealed source might

have been damaged or might be leaking, the licensee or registrant shall assure that the

sealed source is tested for leakage or contamination before further use.

Hazardous Materials and Waste Management

12

4.16.1.5

Tests, and evaluations of tests, for leakage for all sealed sources, except

brachytherapy sources manufactured to contain radium, shall be capable of detecting the

presence of 185 Bq (0.005 µCi) of radioactive material on a test sample. Test samples

shall be taken from the sealed source or from the surfaces of the container in which the

sealed source is stored or mounted on which one might expect contamination to

accumulate. For a sealed source contained in a device, test samples are obtained when

the source is in the “off” position.

4.16.1.6

The test for leakage for brachytherapy sources manufactured to contain radium

shall be capable of detecting an absolute leakage rate of 37 Bq (0.001 µCi) of radon-222

in a 24-hour period when the collection efficiency for radon-222 and its decay products

has been determined with respect to collection method, volume and time.

4.16.1.7

Tests for contamination from radium decay products shall be taken on the interior

surface of brachytherapy source storage containers and shall be capable of detecting the

presence of 185 Bq (0.005 µCi) of a radium decay product which has a half-life greater

than 4 days.

4.16.2 A licensee or registrant need not perform test for leakage or contamination on the following

sealed sources:

4.16.2.1

Sealed sources containing only radioactive material with a half-life of less than 30

days;

4.16.2.2

Sealed sources containing only radioactive material as a gas;

4.16.2.3

Sealed sources containing 3.7 MBq (100 µCi) or less of beta or photon-emitting

material or 370 kBq (10 µCi) or less of alpha-emitting material;

4.16.2.4

Sealed sources containing only hydrogen-3;

4.16.2.5

Seeds of iridium-192 encased in nylon ribbon; and

4.16.2.6

Sealed sources, except teletherapy and brachytherapy sources, which are

stored, not being used and identified as in storage. The licensee or registrant shall,

however, test each such sealed source for leakage or contamination and receive the test

results before any use or transfer unless it has been tested for leakage or contamination

within 6 months before the date of use or transfer.

4.16.3 Tests for leakage or contamination from sealed sources shall be performed by persons

specifically authorized by the Department, an Agreement State, a Licensing State, or the U.S.

Nuclear Regulatory Commission to perform such services.

4.16.4 Test results shall be kept in units of becquerel (or microcurie) and maintained for inspection by

the Department. Records of test results for sealed sources shall be made and retained as

specified in 4.43.

4.16.5 The following shall be considered evidence that a sealed source is leaking:

4.16.5.1

The presence of 185 Bq (0.005 µCi) or more of removable contamination on any

test sample.

4.16.5.2

Leakage of 37 Bq (0.001 µCi) of radon-222 per 24 hours for brachytherapy

sources manufactured to contain radium.

Hazardous Materials and Waste Management

13

4.16.5.3

The presence of removable contamination resulting from the decay of 185 Bq

(0.005 µCi) or more of radium.

4.16.6 The licensee or registrant shall immediately withdraw a leaking sealed source from use and shall

take action to prevent the spread of contamination. The leaking sealed source shall be repaired

or disposed of in accordance with this Part.

4.16.7 Reports of test results for leaking or contaminated sealed sources shall be made pursuant to

4.58.

SURVEYS AND MONITORING

4.17

General.

4.17.1 Each licensee or registrant shall make, or cause to be made, surveys of areas, including areas of

subsurface radioactivity identified at the site, that:

4.17.1.1

Are necessary for the licensee or registrant to comply with Part 4; and

4.17.1.2

Are necessary under the circumstances to evaluate:

(1)

The magnitude and extent of radiation levels; and

(2)

Concentrations or quantities of residual radioactivity; and

(3)

The potential radiological hazards.

4.17.2 Notwithstanding 4.42.1, records from surveys describing the location and amount of subsurface

residual radioactivity identified at the site must be kept with records important for

decommissioning, and such records must be retained in accordance with 3.16.5, as applicable.

4.17.3 The licensee or registrant shall ensure that instruments and equipment used for quantitative

radiation measurements, for example, dose rate and effluent monitoring, are calibrated at

intervals not to exceed 12 months for the radiation measured unless otherwise noted in these

regulations.

4.17.4 All personnel dosimeters, except for direct and indirect reading pocket ionization chambers and

those dosimeters used to measure the dose to any extremity, that require processing to

determine the radiation dose and that are used by licensees and registrants to comply with 4.6,

with other applicable provisions of these regulations, or with conditions specified in a license or

registration shall be processed and evaluated by a dosimetry processor:

4.17.4.1

Holding current personnel dosimetry accreditation from the National Voluntary

Laboratory Accreditation Program (NVLAP) of the National Institute of Standards and

Technology; and

4.17.4.2

Approved in this accreditation process for the type of radiation or radiations

included in the NVLAP program that most closely approximates the type of radiation or

radiations for which the individual wearing the dosimeter is monitored.

4.17.5 The licensee or registrant shall ensure that adequate precautions are taken to prevent a

deceptive exposure of an individual monitoring device.

Hazardous Materials and Waste Management

14

4.18

Conditions Requiring Individual Monitoring of External and Internal Occupational Dose.

Each licensee or registrant shall monitor exposures from sources of radiation at levels sufficient

to demonstrate compliance with the occupational dose limits of Part 4. As a minimum:

4.18.1 Each licensee or registrant shall monitor occupational exposure to radiation from licensed and

unlicensed radiation sources under the control of the licensee or the registrant and shall supply

and require the use of individual monitoring devices by:

4.18.1.1

Adults likely to receive, in 1 year from sources external to the body, a dose in

excess of 10 percent of the limits in 4.6.1;

4.18.1.2

Minors likely to receive, in 1 year from radiation sources external to the body, a

deep dose equivalent in excess of 1 mSv (0.1 rem), a lens dose equivalent in excess of

1.5 mSv (0.15 rem), or a shallow dose equivalent to the skin or to the extremities in

excess 5 mSv (0.5 rem);

4.18.1.3

Declared pregnant women likely to receive during the entire pregnancy, from

radiation sources external to the body, a deep dose equivalent in excess of 1 mSv (0.1

rem)3; and

3 All of the occupational doses in 4.6 continue to be applicable to the declared pregnant worker as long as the embryo/fetus dose

limit is not exceeded.

4.18.1.4

Individuals entering a high radiation area or a very high radiation area.

4.18.2 Each licensee or registrant shall monitor, to determine compliance with 4.9, the occupational

intake of radioactive material by and assess the committed effective dose equivalent to:

4.18.2.1

Adults likely to receive, in 1 year, an intake in excess of 10 percent of the

applicable ALI(s) in Table 4B1, Columns 1 and 2, of Appendix 4B;

4.18.2.2

Minors likely to receive, in 1 year, a committed effective dose equivalent in

excess of 1 mSv (0.1 rem); and

4.18.2.3

Declared pregnant women likely to receive during the entire pregnancy, a

committed effective dose equivalent in excess of 1 mSv (0.1 rem).

4.18.3 Registrants shall maintain records of the evaluation of likely external dose and the determination

to monitor or not monitor individuals to demonstrate compliance with the occupational dose limits

of Part 4. The registrant shall retain the record required by 4.18.3 for inspection until the

Department terminates the registration requiring the record.

CONTROL OF EXPOSURE FROM EXTERNAL SOURCES IN RESTRICTED AREAS

4.19

Control of Access to High Radiation Areas.

4.19.1 The licensee or registrant shall ensure that each entrance or access point to a high radiation area

has one or more of the following features:

4.19.1.1

A control device that, upon entry into the area, causes the level of radiation to be

reduced below that level at which an individual might receive a deep dose equivalent of 1

mSv (0.1 rem) in 1 hour at 30 centimeters from the source of radiation from any surface

that the radiation penetrates; or

Hazardous Materials and Waste Management

15

4.19.1.2

A control device that energizes a conspicuous visible or audible alarm signal so

that the individual entering the high radiation area and the supervisor of the activity are

made aware of the entry; or

4.19.1.3

Entryways that are locked, except during periods when access to the areas is

required, with positive control over each individual entry.

4.19.2 In place of the controls required by 4.19.1 for a high radiation area, the licensee or registrant may

substitute continuous direct or electronic surveillance that is capable of preventing unauthorized

entry.

4.19.3 The licensee or registrant may apply to the Department for approval of alternative methods for

controlling access to high radiation areas.

4.19.4 The licensee or registrant shall establish the controls required by 4.19.1 and 4.19.3 in a way that

does not prevent individuals from leaving a high radiation area.

4.19.5 The licensee or registrant is not required to control each entrance or access point to a room or

other area that is a high radiation area solely because of the presence of radioactive materials

prepared for transport and packaged and labeled in accordance with the regulations of the U.S.

Department of Transportation provided that:

4.19.5.1

The packages do not remain in the area longer than 3 days; and

4.19.5.2

The dose rate at 1 meter from the external surface of any package does not

exceed 0.1 mSv (0.01 rem) per hour.

4.19.6 The licensee or registrant is not required to control entrance or access to rooms or other areas in

hospitals solely because of the presence of patients containing radioactive material, provided that

there are personnel in attendance who are taking the necessary precautions to prevent the

exposure of individuals to radiation or radioactive material in excess of the established limits in

Part 4 and to operate within the ALARA provisions of the licensee's or registrant's radiation

protection program.

4.19.7 The licensee or registrant is not required to control entrance or access to rooms or other areas

containing sources of radiation capable of producing a high radiation area as described in 4.19 if

the licensee or registrant has met all the specific requirements for access and control specified in

other applicable parts of these regulations, such as, Part 5 for industrial radiography, Part 6 for x-

rays in the healing arts, and Part 9 for particle accelerators not used in the healing arts.

4.20

Control of Access to Very High Radiation Areas.

4.20.1 In addition to the requirements in 4.19, the licensee or registrant shall institute measures to

ensure that an individual is not able to gain unauthorized or inadvertent access to areas in which

radiation levels could be encountered at 5 Gy (500 rad) or more in 1 hour at 1 meter from a

source of radiation or any surface through which the radiation penetrates. This requirement does

not apply to rooms or areas in which diagnostic x-ray systems are the only source of radiation, or

to non-self-shielded irradiators.

4.20.2 The registrant is not required to control entrance or access to rooms or other areas containing

sources of radiation capable of producing a very high radiation area as described in 4.20.1 if the

registrant has met all the specific requirements for access and control specified in other

applicable parts of these regulations, such as, Part 5 for industrial radiography, Part 6 for x-rays

in the healing arts, and Part 9 for particle accelerators not used in the healing arts.

Hazardous Materials and Waste Management

16

4.21

Control of Access to Very High Radiation Areas - Irradiators.

4.21.1 Section 4.21 applies to licensees or registrants with sources of radiation in non-self-shielded

irradiators. Section 4.21 does not apply to sources of radiation that are used in teletherapy, in

industrial radiography, or in completely self-shielded irradiators in which the source of radiation is

both stored and operated within the same shielding radiation barrier and, in the designed

configuration of the irradiator, is always physically inaccessible to any individual and cannot

create high levels of radiation in an area that is accessible to any individual.

4.21.2 Each area in which there may exist radiation levels in excess of 5 Gy (500 rad) in 1 hour at 1

meter from a source of radiation that is used to irradiate materials shall meet the following

requirements:

4.21.2.1

Each entrance or access point shall be equipped with entry control devices

which:

(1)

Function automatically to prevent any individual from inadvertently entering a

very high radiation area; and

(2)

Permit deliberate entry into the area only after a control device is actuated that

causes the radiation level within the area, from the source of radiation, to be

reduced below that at which it would be possible for an individual to receive a

deep dose equivalent in excess of 1 mSv (0.1 rem) in 1 hour; and

(3)

Prevent operation of the source of radiation if it would produce radiation levels in

the area that could result in a deep dose equivalent to an individual in excess of

1 mSv (0.1 rem) in 1 hour.

4.21.2.2

Additional control devices shall be provided so that, upon failure of the entry

control devices to function as required by 4.21.2.1:

(1)

The radiation level within the area, from the source of radiation, is reduced below

that at which it would be possible for an individual to receive a deep dose

equivalent in excess of 1 mSv (0.1 rem) in 1 hour; and

(2)

Conspicuous visible and audible alarm signals are generated to make an

individual attempting to enter the area aware of the hazard and at least one other

authorized individual, who is physically present, familiar with the activity, and

prepared to render or summon assistance, aware of the failure of the entry

control devices.

4.21.2.3

The licensee or registrant shall provide control devices so that, upon failure or

removal of physical radiation barriers other than the sealed source's shielded storage

container:

(1)

The radiation level from the source of radiation is reduced below that at which it

would be possible for an individual to receive a deep dose equivalent in excess

of 1 mSv (0.1 rem) in 1 hour; and

(2)

Conspicuous visible and audible alarm signals are generated to make potentially

affected individuals aware of the hazard and the licensee or registrant or at least

one other individual, who is familiar with the activity and prepared to render or

summon assistance, aware of the failure or removal of the physical barrier.

Hazardous Materials and Waste Management

17

4.21.2.4

When the shield for stored sealed sources is a liquid, the licensee or registrant

shall provide means to monitor the integrity of the shield and to signal, automatically, loss

of adequate shielding.

4.21.2.5

Physical radiation barriers that comprise permanent structural components, such

as walls, that have no credible probability of failure or removal in ordinary circumstances

need not meet the requirements of 4.21.2.3 and 4.21.2.4.

4.21.2.6

Each area shall be equipped with devices that will automatically generate

conspicuous visible and audible alarm signals to alert personnel in the area before the

source of radiation can be put into operation and in time for any individual in the area to

operate a clearly identified control device, which must be installed in the area and which

can prevent the source of radiation from being put into operation.

4.21.2.7

Each area shall be controlled by use of such administrative procedures and such

devices as are necessary to ensure that the area is cleared of personnel prior to each

use of the source of radiation.

4.21.2.8

Each area shall be checked by a radiation measurement to ensure that, prior to

the first individual's entry into the area after any use of the source of radiation, the

radiation level from the source of radiation in the area is below that at which it would be

possible for an individual to receive a deep dose equivalent in excess of 1 mSv (0.1 rem)

in 1 hour.

4.21.2.9

The entry control devices required in 4.21.2.1 shall be tested for proper

functioning. See 4.49 for recordkeeping requirements.

(1)

Testing shall be conducted prior to initial operation with the source of radiation on

any day, unless operations were continued uninterrupted from the previous day;

and

(2)

Testing shall be conducted prior to resumption of operation of the source of

radiation after any unintentional interruption; and

(3)

The licensee or registrant shall submit and adhere to a schedule for periodic

tests of the entry control and warning systems.

4.21.2.10

The licensee or registrant shall not conduct operations, other than those

necessary to place the source of radiation in safe condition or to effect repairs on

controls, unless control devices are functioning properly.

4.21.2.11

Entry and exit portals that are used in transporting materials to and from the

irradiation area, and that are not intended for use by individuals, shall be controlled by

such devices and administrative procedures as are necessary to physically protect and

warn against inadvertent entry by any individual through these portals. Exit portals for

irradiated materials shall be equipped to detect and signal the presence of any loose

radioactive material that is carried toward such an exit and to automatically prevent loose

radioactive material from being carried out of the area.

Hazardous Materials and Waste Management

18

4.21.3 Licensees, registrants, or applicants for licenses or registrations for sources of radiation within the

purview of 4.21.2 which will be used in a variety of positions or in locations, such as open fields or

forests, that make it impracticable to comply with certain requirements of 4.21.2, such as those

for the automatic control of radiation levels, may apply to the Department for approval of

alternative safety measures. Alternative safety measures shall provide personnel protection at

least equivalent to those specified in 4.21.2. At least one of the alternative measures shall include

an entry-preventing interlock control based on a measurement of the radiation that ensures the

absence of high radiation levels before an individual can gain access to the area where such

sources of radiation are used.

4.21.4 The entry control devices required by 4.21.2 and 4.21.3 shall be established in such a way that

no individual will be prevented from leaving the area.

RESPIRATORY PROTECTION AND CONTROLS TO RESTRICT INTERNAL EXPOSURE IN

RESTRICTED AREAS

4.22

Use of Process or Other Engineering Controls.

The licensee shall use, to the extent practical, process or other engineering controls, such as

containment, decontamination or ventilation, to control the concentrations of radioactive material

in air.

4.23

Use of Other Controls.

4.23.1 When it is not practical to apply process or other engineering controls to control the

concentrations of radioactive material in air to values below those that define an airborne

radioactivity area, the licensee shall, consistent with maintaining the total effective dose

equivalent ALARA, increase monitoring and limit intakes by one or more of the following means:

4.23.1.1

Control of access; or

4.23.1.2

Limitation of exposure times; or

4.23.1.3

Use of respiratory protection equipment; or

4.23.1.4

Other controls.

4.23.2 If the licensee performs an ALARA analysis to determine whether or not respirators should be

used, the licensee may consider safety factors other than radiological factors. The licensee

should also consider the impact of respirator use on workers' industrial health and safety.

4.24

Use of Individual Respiratory Protection Equipment.

4.24.1 If the licensee uses respiratory protection equipment to limit intakes pursuant to 4.23:

4.24.1.1

Except as provided in 4.24.1.2, the licensee shall use only respiratory protection

equipment that is tested and certified or had certification extended by the National

Institute for Occupational Safety and Health and the Mine Safety and Health

Administration.

Hazardous Materials and Waste Management

19

4.24.1.2

If the licensee wishes to use equipment that has not been tested or certified by

the National Institute for Occupational Safety and Health and the Mine Safety and Health

Administration, or has not had certification extended by the National Institute for

Occupational Safety and Health and the Mine Safety and Health Administration, or for

which there is no schedule for testing or certification, the licensee shall submit an

application for authorized use of that equipment, including a demonstration by testing, or

a demonstration on the basis of reliable test information, that the material and

performance characteristics of the equipment are capable of providing the proposed

degree of protection under anticipated conditions of use.

4.24.1.3

The licensee shall implement and maintain a respiratory protection program that

includes:

(1)

Air sampling sufficient to identify the potential hazard, permit proper equipment

selection, and estimate exposures; and

(2)

Surveys and bioassays, as appropriate, to evaluate actual intakes; and

(3)

Testing of respirators for operability (user seal check for face sealing devices and

functional check for others) immediately prior to each use; and

(4)

Written procedures regarding selection, fitting, issuance, maintenance, repair,

quality assurance, storage and testing of respirators, including testing for

operability immediately prior to each use; supervision and training of personnel;

limitations on periods of respirator use and relief from respirator use; breathing

air quality; monitoring, including air sampling and bioassays; inventory, control

and recordkeeping; and

(5)

Determination by a physician, prior to initial fitting of respirators, before the first

field use of non-face-sealing respirators, and either every 12 months thereafter or

periodically at a frequency determined by a physician, that the individual user is

medically fit to use the respiratory protection equipment.

(6)

Fit testing, with fit factor 10 times the assigned protection factor (APF) for

negative pressure devices, and a fit factor greater than or equal to 500 for any

positive pressure, continuous flow, and pressure demand devices, before the first

field use of tight-fitting, face-sealing respirators and periodically thereafter at a

frequency not to exceed 1 year. Fit testing must be performed with the facepiece

operating in the negative pressure mode.

4.24.1.4

The licensee shall:

(1)

Issue a written policy statement on respirator usage covering:

(a)

The use of process or other engineering controls, instead of respirators;

and

(b)

The routine, nonroutine, and emergency use of respirators; and

(c)

The length of periods of respirator use and relief from respirator use; and

Hazardous Materials and Waste Management

20

(2)

Advise each respirator user that the user may leave the area at any time for relief

from respirator use in the event of equipment malfunction, physical or

psychological distress, procedural or communication failure, significant

deterioration of operating conditions, or any other conditions that might require

such relief.

4.24.1.5

The licensee shall also consider limitations appropriate to the type and mode of

use. When selecting respiratory devices the licensee shall provide for vision correction,

adequate communication, low temperature work environments, and the concurrent use of

other safety or radiological protection equipment. The licensee shall use equipment in

such a way as not to interfere with the proper operation of the respirator.

4.24.1.6

Standby rescue persons are required whenever one piece atmosphere supplying

suits, or any combination of supplied air respiratory protection device and personnel

protective equipment are used from which an unaided individual would have difficulty

extricating himself or herself. The standby persons must be equipped with respiratory

protection devices or other apparatus appropriate for the potential hazards. The standby

rescue persons shall observe or otherwise maintain continuous communication with the

workers (visual, voice, signal line, telephone, radio, or other suitable means), and be

immediately available to assist them in case of a failure of the air supply or for any other

reason that requires relief from distress. A sufficient number of standby rescue persons

must be immediately available to assist all users of this type of equipment and to provide

effective emergency rescue if needed.

4.24.1.7

Atmosphere-supplying respirators must be supplied with respirable air of Grade

D quality or better as defined by the Compressed Gas Association in Publication G-7.1,

“Commodity Specification For Air,” edition 5, published August 27, 2004, and included in

the regulations of the Occupational Safety And Health Administration (29 CFR

1910.134(i)(1)(ii)(A) through (E), July 1, 2004).

Grade D quality air criteria include:

(1)

Oxygen content (V/V) between 19.5 per cent and 23.5 per cent;

(2)

Hydrocarbon (condensed) content of 5 milligrams per cubic meter of air or less;

(3)

Carbon monoxide (CO) content of 10 parts per million or less;

(4)

Carbon dioxide content of 1,000 parts per million or less; and

(5)

Lack of noticeable odor.

4.24.1.8

The licensee shall ensure that no objects, materials or substances, such as facial

hair, or any conditions that interfere with the face, facepiece seal or valve function, and

that are under the control of the respirator wearer, are present between the skin of the

wearer's face and the sealing surface of a tight fitting respirator facepiece.

4.24.1.9

In estimating the dose to individuals from intake of airborne radioactive materials,

the concentration of radioactive material in the air that is inhaled when respirators are

worn is initially assumed to be the ambient concentration in air without respiratory

protection, divided by the assigned protection factor. If the dose is later found to be

greater than the estimated dose, the corrected value must be used. If the dose is later

found to be less than the estimated dose, the corrected value may be used.

Hazardous Materials and Waste Management

21

4.24.2 When estimating exposure of individuals to airborne radioactive materials, the licensee may make

allowance for respiratory protection equipment used to limit intakes pursuant to 4.23, provided

that the following conditions, in addition to those in 4.24.1, are satisfied:

4.24.2.1

The licensee selects respiratory protection equipment that provides a protection

factor, specified in Appendix 4A, greater than the multiple by which peak concentrations

of airborne radioactive materials in the working area are expected to exceed the values

specified in Appendix 4B, Table 4B1, Column 3. However, if the selection of respiratory

protection equipment with a protection factor greater than the multiple defined in the

preceding sentence is inconsistent with the goal specified in 4.23 of keeping the total

effective dose equivalent ALARA, the licensee may select respiratory protection

equipment with a lower protection factor provided that such a selection would result in a

total effective dose equivalent that is ALARA. The concentration of radioactive material in

the air that is inhaled when respirators are worn may be initially estimated by dividing the

average concentration in air, during each period of uninterrupted use, by the protection

factor. If the exposure is later found to be greater than initially estimated, the corrected

value shall be used; if the exposure is later found to be less than initially estimated, the

corrected value may be used.

4.24.2.2

The licensee shall obtain authorization from the Department before assigning

respiratory protection factors in excess of those specified in Appendix 4A. The

Department may authorize a licensee to use higher protection factors on receipt of an

application that:

(1)

Describes the situation for which a need exists for higher protection factors, and

(2)

Demonstrates that the respiratory protection equipment provides these higher

protection factors under the proposed conditions of use.

4.24.3 In an emergency, the licensee shall use as emergency equipment only respiratory protection

equipment that has been specifically certified or had certification extended for emergency use by

the National Institute for Occupational Safety and Health and the Mine Safety and Health

Administration.

4.24.4 The licensee shall notify the Department in writing at least 30 days before the date that

respiratory protection equipment is first used pursuant to either 4.24.1 or 4.24.2.

4.24.5 The Department may impose restrictions in addition to the provisions of 4.23.2, 4.24.1, and

Appendix 4A, in order to:

4.24.5.1

Ensure that the respiratory protection program of the licensee is adequate to limit

doses to individuals from intakes of airborne radioactive materials consistent with

maintaining total effective dose equivalent ALARA; and

4.24.5.2

Limit the extent to which a licensee may use respiratory protection equipment

instead of process or other engineering controls.

STORAGE AND CONTROL OF LICENSED OR REGISTERED SOURCES OF RADIATION

4.25

Security of Stored Sources of Radiation.

4.25.1 The licensee shall secure from unauthorized removal or access licensed or registered sources of

radiation that are stored in unrestricted areas.

Hazardous Materials and Waste Management

22

4.25.2 Security requirements for portable gauges.

Each portable gauge licensee shall use a minimum of two independent physical controls that form

tangible barriers to secure portable gauges from unauthorized removal, whenever portable

gauges are not under the control and constant surveillance of the licensee.

4.26

Control of Sources of Radiation not in Storage.

4.26.1 The licensee shall control and maintain constant surveillance of licensed or registered radioactive

material that is in an unrestricted area and that is not in storage or in a patient.

4.26.2 The registrant shall maintain control of radiation machines that are in an unrestricted area and

that are not in storage.

PRECAUTIONARY PROCEDURES

4.27

Caution Signs.

4.27.1 Standard Radiation Symbol. Unless otherwise authorized by the Department, the symbol

prescribed by 4.27 shall use the colors magenta, or purple, or black on yellow background. The

symbol prescribed is the three-bladed design as follows:

RADIATION SYMBOL

4.27.1.1.

Cross-hatched area is to be magenta, or purple, or black, and

4.27.1.2.

The background is to be yellow.

Hazardous Materials and Waste Management

23

4.27.2 Exception to Color Requirements for Standard Radiation Symbol.

Notwithstanding the requirements of 4.27.1, licensees or registrants are authorized to label

sources, source holders, or device components containing sources of radiation that are subjected

to high temperatures, with conspicuously etched or stamped radiation caution symbols and

without a color requirement.

4.27.3 Additional Information on Signs and Labels.

In addition to the contents of signs and labels prescribed in Part 4, the licensee may provide, on

or near the required signs and labels, additional information, as appropriate, to make individuals

aware of potential radiation exposures and to minimize the exposures.

4.28

Posting Requirements.

4.28.1 Posting of Radiation Areas.

The licensee or registrant shall post each radiation area with a conspicuous sign or signs bearing

the radiation symbol prescribed in 4.27 and the words “CAUTION, RADIATION AREA.”

4.28.2 Posting of High Radiation Areas.

The licensee or registrant shall post each high radiation area with a conspicuous sign or signs

bearing the radiation symbol prescribed in 4.27 and the words “CAUTION, HIGH RADIATION

AREA” or “DANGER, HIGH RADIATION AREA.”

4.28.3 Posting of Very High Radiation Areas.

The licensee or registrant shall post each very high radiation area with a conspicuous sign or

signs bearing the radiation symbol prescribed in 4.27 and words “GRAVE DANGER, VERY HIGH

RADIATION AREA.”

4.28.4 Posting of Airborne Radioactivity Areas.

The licensee or registrant shall post each airborne radioactivity area with a conspicuous sign or

signs bearing the radiation symbol prescribed in 4.27 and the words “CAUTION, AIRBORNE

RADIOACTIVITY AREA” or “DANGER, AIRBORNE RADIOACTIVITY AREA.”

4.28.5 Posting of Areas or Rooms in which Licensed or Registered Material is Used or Stored.

The licensee or registrant shall post each area or room in which there is used or stored an

amount of licensed or registered material exceeding 10 times the quantity of such material

specified in Appendix 4C with a conspicuous sign or signs bearing the radiation symbol

prescribed in 4.27 and the words “CAUTION, RADIOACTIVE MATERIAL(S)” or “DANGER,

RADIOACTIVE MATERIAL(S).”

4.29

Exceptions to Posting Requirements.

4.29.1 A licensee or registrant is not required to post caution signs in areas or rooms containing sources

of radiation for periods of less than 8 hours, if each of the following conditions is met:

4.29.1.1

The sources of radiation are constantly attended during these periods by an

individual who takes the precautions necessary to prevent the exposure of individuals to

sources of radiation in excess of the limits established in Part 4; and

Hazardous Materials and Waste Management

24

4.29.1.2

The area or room is subject to the licensee's or registrant's control.

4.29.2 Rooms or other areas in hospitals that are occupied by patients are not required to be posted with

caution signs pursuant to 4.28 provided that the total effective dose equivalent to individual

members of the public from the patient does not exceed 1 millisievert (0.1 rem) in a year.

4.29.3 A room or area is not required to be posted with a caution sign because of the presence of a

sealed source provided the radiation level at 30 centimeters from the surface of the sealed source

container or housing does not exceed 0.05 mSv (0.005 rem) per hour.

4.29.4 Rooms in hospitals or clinics that are used for teletherapy are exempt from the requirement to

post caution signs under 4.28 if:

4.29.4.1

Access to the room is controlled pursuant to 7.52; and

4.29.4.2

Personnel in attendance take necessary precautions to prevent the inadvertent

exposure of workers, other patients, and members of the public to radiation in excess of

the limits established in this part.

4.29.5 A room or area is not required to be posted with a caution sign because of the presence of

radiation machines used solely for diagnosis in the healing arts.

4.30

Labeling Containers and Radiation Machines.

4.30.1 The licensee or registrant shall ensure that each container of licensed or registered material

bears a durable, clearly visible label bearing the radiation symbol prescribed in 4.27 and the

words “CAUTION, RADIOACTIVE MATERIAL” or “DANGER, RADIOACTIVE MATERIAL.” The

label shall also provide information, such as the radionuclides present, an estimate of the quantity

of radioactivity, the date for which the activity is estimated, radiation levels, kinds of materials,

and mass enrichment, to permit individuals handling or using the containers, or working in the

vicinity of the containers, to take precautions to avoid or minimize exposures.

4.30.2 Each licensee or registrant shall, prior to removal or disposal of empty uncontaminated containers

to unrestricted areas, remove or deface the radioactive material label or otherwise clearly indicate

that the container no longer contains radioactive materials.

4.30.3 Each registrant shall ensure that each radiation machine is labeled in a conspicuous manner,

which cautions individuals that radiation is produced when it is energized.

4.31

Exemptions to Labeling Requirements.

A licensee or registrant is not required to label:

4.31.1 Containers holding licensed or registered material in quantities less than the quantities listed in

Appendix 4C; or

4.31.2 Containers holding licensed or registered material in concentrations less than those specified in

Table 4B3 of Appendix 4B; or

4.31.3 Containers attended by an individual who takes the precautions necessary to prevent the

exposure of individuals in excess of the limits established by Part 4; or

Hazardous Materials and Waste Management

25

4.31.4 Containers when they are in transport and packaged and labeled in accordance with the

regulations of the U.S. Department of Transportation4 or

4 Labeling of packages containing radioactive materials is required by the U.S. Department of Transportation if the amount and type

of radioactive material exceeds the limits for an excepted quantity or article as defined and limited by U.S. Department of

Transportation regulations 49 CFR 173.403(m) and (w) and 173.421-424, October 1, 2003.

4.31.5 Containers that are accessible only to individuals authorized to handle or use them, or to work in

the vicinity of the containers, if the contents are identified to these individuals by a readily

available written record. Examples of containers of this type are containers in locations such as

water-filled canals, storage vaults, or hot cells. The record shall be retained as long as the

containers are in use for the purpose indicated on the record; or

4.31.6 Installed manufacturing or process equipment, such as piping and tanks.

4.32

Procedures for Receiving and Opening Packages.

4.32.1 Each licensee or registrant who expects to receive a package containing quantities of radioactive

material in excess of a Type A quantity, as defined in 17.2 and Appendix 17A of Part 17 of these

regulations, shall make arrangements to receive:

4.32.1.1

The package when the carrier offers it for delivery; or

4.32.1.2

The notification of the arrival of the package at the carrier's terminal and to take

possession of the package expeditiously.

4.32.2 Each licensee or registrant shall:

4.32.2.1

Monitor the external surfaces of a labeled5 package for radioactive contamination

unless the package contains only radioactive material in the form of gas or in special form

as defined in 1.2 of these regulations; and

5 Labeled with a Radioactive White I, Yellow II, or Yellow III label as specified in U.S. Department of Transportation regulations 49

CFR 172.403 and 172.436-440, October 1, 2003.

4.32.2.2

Monitor the external surfaces of a labeled6 package for radiation levels unless the

package contains quantities of radioactive material that are less than or equal to the Type

A quantity, as defined in 17.2 and Appendix 17A to Part 17 of these regulations; and

6 Labeled with a Radioactive White I, Yellow II, or Yellow III label as specified in U.S. Department of Transportation regulations 49

CFR 172.403 and 172.436-440, October 1, 2003.

4.32.2.3

Monitor all packages known to contain radioactive material for radioactive

contamination and radiation levels if there is evidence of degradation of package

integrity, such as packages that are crushed, wet, or damaged.

4.32.3 The licensee or registrant shall perform the monitoring required by 4.32.2 as soon as practical

after receipt of the package, but not later than 3 hours after the package is received at the

licensee's or registrant's facility if it is received during the licensee's or registrant's normal working

hours, or not later than 3 hours from the beginning of the next working day if it is received after

working hours.

4.32.4 The licensee or registrant shall immediately notify the final delivery carrier and the Department by

telephone, when:

4.32.4.1

Removable radioactive surface contamination exceeds the limits of 17.15.8 of

these regulations; or

Hazardous Materials and Waste Management

26

4.32.4.2

External radiation levels exceed the limits of 17.15.9 and 17.15.10 of these

regulations.

4.32.5 Each licensee or registrant shall:

4.32.5.1

Establish, maintain, and retain written procedures for safely opening packages in

which radioactive material is received; and

4.32.5.2

Ensure that the procedures are followed and that due consideration is given to

special instructions for the type of package being opened.

4.32.6 Licensees or registrants transferring special form sources in vehicles owned or operated by the

licensee or registrant to and from a work site are exempt from the contamination monitoring

requirements of 4.32.2, but are not exempt from the monitoring requirement in 4.32.2 for

measuring radiation levels that ensures that the source is still properly lodged in its shield.

WASTE DISPOSAL

4.33

General Requirements.

4.33.1 A licensee or registrant shall dispose of licensed or registered material only:

4.33.1.1

By transfer to an authorized recipient as provided in 4.38 or in Parts 3, 14, or 18

of these regulations, or to the U.S. Department of Energy; or

4.33.1.2

By decay in storage in accordance with the following:

(1)

A licensee may hold radioactive material with a physical half-life of less than or

equal to 120 days for decay-in-storage before disposal without regard for its

radioactivity if the licensee:

(a)

Monitors radioactive material at the container surface before disposal

and determines that its radioactivity cannot be distinguished from the

background radiation level with a radiation detection survey instrument

set on its most sensitive scale and with no interposed shielding; and

(b)

Removes or obliterates all radiation labels, except for material that will be

handled as biomedical waste after release;

or

4.33.1.3

By release in effluents within the limits in 4.14; or

4.33.1.4

As authorized pursuant to 4.34, 4.35, 4.36, 4.37 or 4.39.2

4.33.2 A person shall be specifically licensed or registered to receive waste containing licensed or

registered material from other persons for:

4.33.2.1

Treatment prior to disposal; or

4.33.2.2

Treatment or disposal by incineration; or

4.33.2.3

Decay in storage; or

Hazardous Materials and Waste Management

27

4.33.2.4

Disposal at a land disposal facility pursuant to Part 14 of these regulations or as

authorized under Parts 3 or 18 of these regulations; or

4.33.2.5

Storage until transferred to a storage or disposal facility authorized to receive the

waste.

4.34

Method for Obtaining Approval of Proposed Disposal Procedures.

A licensee or registrant or applicant for a license or registration may apply to the Department for

approval of proposed procedures, not otherwise authorized in these regulations, to dispose of

licensed or registered material generated in the licensee's or registrant's operations. Each

application shall include:

4.34.1 A description of the waste containing licensed or registered material to be disposed of, including

the physical and chemical properties that have an impact on risk evaluation, and the proposed

manner and conditions of waste disposal; and

4.34.2 An analysis and evaluation of pertinent information on the nature of the environment; and

4.34.3 The nature and location of other potentially affected facilities; and

4.34.4 Analyses and procedures to ensure that doses are maintained ALARA and within the dose limits

in Part 4.

4.35

Disposal by Release into Sanitary Sewerage.

4.35.1 A licensee or registrant may discharge licensed or registered material into sanitary sewerage if

each of the following conditions is satisfied:

4.35.1.1

The material is “readily soluble,” or is “readily dispersible biological material,” in

water; and

4.35.1.2

The quantity of licensed or registered radioactive material that the licensee or

registrant releases into the sewer in 1 month divided by the average monthly volume of

water released into the sewer by the licensee or registrant does not exceed the

concentration listed in Table 4B3 of Appendix 4B; and

4.35.1.3

If more than one radionuclide is released, the following conditions must also be

satisfied:

(1)

The licensee or registrant shall determine the fraction of the limit in Table 4B3 of

Appendix 4B represented by discharges into sanitary sewerage by dividing the

actual monthly average concentration of each radionuclide released by the

licensee or registrant into the sewer by the concentration of that radionuclide

listed in Table 4B3 of Appendix 4B; and

(2)

The sum of the fractions for each radionuclide required by 4.35.1.3.(1) does not

exceed unity; and

4.35.1.4

The total quantity of licensed or registered radioactive material that the licensee

or registrant releases into the sanitary sewerage in a year does not exceed 185 GBq (5

Ci) of hydrogen-3, 37 GBq (1 Ci) of carbon-14, and 37 GBq (1 Ci) of all other radioactive

materials combined.

Hazardous Materials and Waste Management

28

4.35.2 Excreta from individuals undergoing medical diagnosis or therapy with radioactive material are

not subject to the limitations contained in 4.35.1.

4.36

Treatment or Disposal by Incineration.

4.36.1 A licensee or registrant may treat or dispose of licensed or registered material by incineration only

in the amounts and forms specified in 4.37 or as specifically approved by the Department

pursuant to 4.34.

4.37

Disposal of Specific Wastes.

4.37.1 A licensee or registrant may dispose of the following licensed or registered material as if it were

not radioactive:

4.37.1.1

1.85 kBq (0.05 µCi), or less, of hydrogen-3 or carbon-14 per gram of medium

used for liquid scintillation counting; and

4.37.1.2

1.85 kBq (0.05 µCi), or less, of hydrogen-3 or carbon-14 per gram of animal

tissue, averaged over the weight of the entire animal.

4.37.2 A licensee or registrant shall not dispose of tissue pursuant to 4.37.1.2 in a manner that would

permit its use either as food for humans or as animal feed.

4.37.3 The licensee or registrant shall maintain records in accordance with 4.48.

4.38

Transfer for Disposal and Manifests.

4.38.1 The requirements of 4.38 and Appendix 4D are designed to control transfers of low-level

radioactive waste by any waste generator, waste collector, or waste processor licensee, as

defined in this part, who ships low-level waste either directly, or indirectly through a waste

collector or waste processor, to a licensed low-level radioactive waste disposal facility, establish a

manifest tracking system, and supplement existing requirements concerning transfers and

recordkeeping for those wastes.

4.38.2 Any licensee shipping radioactive waste intended for ultimate disposal at a licensed land disposal

facility shall document the information required on the uniform low-level radioactive waste

manifest and transfer this recorded manifest information to the intended consignee in accordance

with Appendix 4D.

4.38.3 Each shipment manifest shall include a certification by the waste generator as specified in

Section II of Appendix 4D.

4.38.4 Each person involved in the transfer of waste for disposal or in the disposal of waste, including

the waste generator, waste collector, waste processor, and disposal facility operator, shall comply

with the requirements specified in Section III of Appendix 4D.

4.38.5 Any licensee shipping byproduct material as defined in paragraphs (3) and (4) of the definition of

Byproduct material set forth in 1.2. intended for ultimate disposal at a land disposal facility

licensed under 10 CFR Part 61, must document the information required on the NRC’s Uniform

Low-Level Radioactive Waste Manifest and transfer this recorded manifest information to the

intended consignee in accordance with Appendix 4D.

4.39

Additional Disposal Requirements

4.39.1 Compliance with Environmental and Health Protection Regulations.

Hazardous Materials and Waste Management

29

4.39.1.1

Nothing in 4.33, 4.34, 4.35, 4.37, 4.38 or 4.39.2 relieves the licensee or registrant

from complying with other applicable Federal, State and local regulations governing any

other toxic or hazardous properties of materials that may be disposed of pursuant to 4.33,

4.34, 4.35, 4.37, 4.38, or 4.39.2.

4.39.2 Disposal of Certain Byproduct Material

4.39.2.1

Licensed material as defined in paragraphs (3) and (4) of the definition of

Byproduct material set forth in Part 1, Section 1.2 may be disposed of in accordance with

Part 14 or equivalent regulations of NRC or an Agreement State, even though it is not

defined as low-level radioactive waste. Therefore, any licensed material being disposed

of at a facility, or transferred for ultimate disposal at a facility licensed under Part 14, or

equivalent regulations of NRC or Agreement State, must meet the requirements of 4.38.

4.39.2.2

A licensee may dispose of byproduct material, as defined in paragraphs (3) and

(4) of the definition of Byproduct material set forth in Part 1, Section 1.2, at a disposal

facility authorized to dispose of such material in accordance with any Federal or State

solid or hazardous waste law, including the Solid Waste Disposal Act, as authorized

under the Energy Policy Act of 2005.

RECORDS

4.40

General Provisions.

4.40.1 Each person who receives source or radioactive material pursuant to a license issued pursuant to

Part 3 shall keep records showing the receipt, transfer, and disposal of this radioactive material

as follows:

4.40.1.1

The licensee shall retain each record of receipt of source or radioactive material

as long as the material is possessed and for three years following transfer or disposition

of the radioactive material.

4.40.1.2

The licensee who transferred the material shall retain each record of transfer of

source or radioactive material until the Department terminates each license that

authorizes the activity that is subject to the recordkeeping requirement.

4.40.1.3

The licensee shall retain each record of disposal of source or radioactive material

until the Department terminates each license that authorizes the activity that is subject to

the recordkeeping requirement.

4.40.1.4

If source or radioactive material is combined or mixed with other licensed

material and subsequently treated in a manner that makes direct correlation of a receipt

record with a transfer, export, or disposition record impossible, the licensee may use

evaluative techniques (such as first-in-first-out), to make the records that are required by

Part 4 account for 100 percent of the material received.

4.40.2 The licensee shall retain each record that is required by the regulations in this part or by license

condition for the period specified by the appropriate regulation or license condition. If a retention

period is not otherwise specified by regulation or license condition, each record must be

maintained until the Department terminates the license that authorizes the activity that is subject

to the recordkeeping requirement.

4.40.3 Each licensee or registrant shall use the SI units becquerel, gray, sievert and coulomb per

kilogram, or the special units curie, rad, rem and roentgen, including multiples and subdivisions,

and shall clearly indicate the units of all quantities on records required by Part 4.

Hazardous Materials and Waste Management

30

4.40.4 The licensee or registrant shall make a clear distinction among the quantities entered on the

records required by Part 4 (e.g., total effective dose equivalent, total organ dose equivalent,

shallow dose equivalent, lens dose equivalent, deep dose equivalent, committed effective dose

equivalent).

4.40.5 The licensee or registrant shall be consistent in their use of SI or special units. The licensee or

registrant shall not change the units used on records required by Part 4 except at the beginning of

the calendar year or with Department approval.

4.41

Records of Radiation Protection Programs.

4.41.1 Each licensee or registrant shall maintain records of the radiation protection program, including:

4.41.1.1

The provisions of the program; and

4.41.1.2

Audits and other reviews of program content and implementation.

4.41.2 The licensee or registrant shall retain the records required by 4.41.1.1 until the Department

terminates each pertinent license or registration requiring the record. The licensee or registrant

shall retain the records required by 4.41.1.2 for 3 years after the record is made.

4.42

Records of Surveys.

4.42.1 Each licensee or registrant shall maintain records showing the results of surveys and calibrations

required by 4.17 and 4.32.2. The licensee or registrant shall retain these records for 3 years after

the record is made.

4.42.2 The licensee or registrant shall retain each of the following records until the Department

terminates each pertinent license or registration requiring the record:

4.42.2.1

Records of the results of surveys to determine the dose from external sources of

radiation and used, in the absence of or in combination with individual monitoring data, in

the assessment of individual dose equivalents; and

4.42.2.2

Records of the results of measurements and calculations used to determine

individual intakes of radioactive material and used in the assessment of internal dose;

and

4.42.2.3

Records showing the results of air sampling, surveys, and bioassays required

pursuant to 4.24.1.3(1) and 4.24.1.3(2); and

4.42.2.4

Records of the results of measurements and calculations used to evaluate the

release of radioactive effluents to the environment.

4.42.3 Upon termination of the license or registration, the licensee or registrant shall permanently store

records on Department Form R-16 or equivalent, or shall make provision with the Department for

transfer to the Department.

4.43

Records of Tests for Leakage or Contamination of Sealed Sources.

Records of tests for leakage or contamination of sealed sources required by 4.16 shall be kept in

units of becquerel (or microcurie) and maintained for inspection by the Department for 5 years

after the records are made.

Hazardous Materials and Waste Management

31

4.44

Records of Prior Occupational Dose.

4.44.1 The licensee or registrant shall retain the records of prior occupational dose and exposure history

as specified in 4.10 on Department Form R-16 or equivalent until the Department terminates each

pertinent license or registration requiring this record. The licensee or registrant shall retain

records used in preparing Department Form R-16 or equivalent for 3 years after the record is

made.

4.44.2 Upon termination of the license or registration, the licensee or registrant shall permanently store

records on Department Form R-16 or equivalent, or shall make provision with the Department for

transfer to the Department.

4.45

Records of Planned Special Exposures.

4.45.1 For each use of the provisions of 4.11 for planned special exposures, the licensee or registrant

shall maintain records that describe:

4.45.1.1

The exceptional circumstances requiring the use of a planned special exposure;

and

4.45.1.2

The name of the management official who authorized the planned special

exposure and a copy of the signed authorization; and

4.45.1.3

What actions were necessary; and

4.45.1.4

Why the actions were necessary; and

4.45.1.5

What precautions were taken to assure that doses were maintained ALARA; and

4.45.1.6

What individual and collective doses were expected to result; and

4.45.1.7

The doses actually received in the planned special exposure.

4.45.2 The licensee or registrant shall retain the records until the Department terminates each pertinent

license or registration requiring these records.

4.45.3 Upon termination of the license or registration, the licensee or registrant shall permanently store

records on Department Form R-16 or equivalent, or shall make provision with the Department for

transfer to the Department.

4.46

Records of Individual Monitoring Results.

4.46.1 Recordkeeping Requirement. Each licensee or registrant shall maintain records of doses

received by all individuals for whom monitoring was required pursuant to 4.18, and records of

doses received during planned special exposures, accidents, and emergency conditions.

Assessments of dose equivalent and records made using units in effect before January 1, 1994

need not be changed. These records shall include, when applicable:

4.46.1.1

The deep dose equivalent to the whole body, lens dose equivalent, shallow dose

equivalent to the skin, and shallow dose equivalent to the extremities;

4.46.1.2

The estimated intake of radionuclides (see 4.7);

4.46.1.3

The committed effective dose equivalent assigned to the intake of radionuclides;

Hazardous Materials and Waste Management

32

4.46.1.4

The specific information used to assess and calculate the committed effective

dose equivalent pursuant to 4.9.1 and 4.9.3, and when required by 4.18;

4.46.1.5

The total effective dose equivalent when required by 4.7; and

4.46.1.6

The total of the deep dose equivalent and the committed dose to the organ

receiving the highest total dose.

4.46.2 Recordkeeping Frequency.

The licensee or registrant shall make entries of the records specified in 4.46.1 at intervals not to

exceed 1 year.

4.46.3 Recordkeeping Format.

The licensee or registrant shall maintain the records specified in 4.46.1 on Department Form R-

17, Occupational Exposure Record for a Monitoring Period, in accordance with the instructions for

Department Form R-17, or in clear and legible records containing all the information required by

Department Form R-17.

4.46.4 The licensee or registrant shall maintain the records of dose to an embryo/fetus with the records

of dose to the declared pregnant woman. The declaration of pregnancy, including the estimated

date of conception, shall also be kept on file, but may be maintained separately from the dose

records.

4.46.5 The licensee or registrant shall retain each required form or record until the Department

terminates each pertinent license or registration requiring the record.

4.46.6 Upon termination of the license or registration, the licensee or registrant shall permanently store

records on Department Form R-16 or equivalent, or shall make provision with the Department for

transfer to the Department.

4.47

Records of Dose to Individual Members of the Public.

4.47.1 Each licensee or registrant shall maintain records sufficient to demonstrate compliance with the

dose limit for individual members of the public. See 4.14.

4.47.2 The licensee or registrant shall retain the records required by 4.47.1 until the Department

terminates each pertinent license or registration requiring the record.

4.48

Records of Waste Disposal.

4.48.1 Each licensee or registrant shall maintain records of the disposal of licensed or registered

materials made pursuant to 4.34, 4.35, 4.36, 4.37, Part 14 of these regulations, and disposal by

burial in soil, including burials authorized before December 30, 1985.

4.48.2 The licensee or registrant shall retain the records required by 4.48.1 in accordance with 3.15.4

until the Department terminates each pertinent license or registration requiring the record.

4.48.3 For radioactive material disposed in accordance with 4.33.1.2, the licensee shall retain a record

of each decay in storage disposal for 3 years. The record must include the date of the disposal,

the survey instrument used, the background radiation level, the radiation level measured at the

surface of each waste container, and the name of the individual who performed the survey.

Hazardous Materials and Waste Management

33

4.49

Records of Testing Entry Control Devices for Very High Radiation Areas.

4.49.1 Each licensee or registrant shall maintain records of tests made pursuant to 4.21.2.9 on entry

control devices for very high radiation areas. These records must include the date, time, and

results of each such test of function.

4.49.2 The licensee or registrant shall retain the records required by 4.49.1 for 3 years after the record is

made.

4.50

Form of Records.

Each record required by Part 4 shall be legible throughout the specified retention period. The

record shall be the original or a reproduced copy or a microform, provided that the copy or

microform is authenticated by authorized personnel and that the microform is capable of

producing a clear copy throughout the required retention period or the record may also be stored

in Department-approved electronic media with the capability for producing legible, accurate, and

complete records during the required retention period. Records, such as letters, drawings, and

specifications, shall include all pertinent information, such as stamps, initials, and signatures. The

licensee shall maintain adequate safeguards against tampering with and loss of records.

REPORTS

4.51

Reports of Stolen, Lost, or Missing Licensed or Registered Sources of Radiation.

4.51.1 Telephone Reports.

Each licensee or registrant shall report to the Department by telephone as follows:

4.51.1.1

Immediately after its occurrence becomes known to the licensee or registrant,

stolen, lost, or missing licensed or registered radioactive material in an aggregate

quantity equal to or greater than 1,000 times the quantity specified in Appendix 4C under

such circumstances that it appears to the licensee or registrant that an exposure could

result to individuals in unrestricted areas; or

4.51.1.2

Within 30 days after its occurrence becomes known to the licensee or registrant,

lost, stolen, or missing licensed or registered radioactive material in an aggregate

quantity greater than 10 times the quantity specified in Appendix 4C that is still missing.

4.51.1.3

Immediately after its occurrence becomes known to the registrant, a stolen, lost,

or missing radiation machine.

4.51.2 Written Reports.

Each licensee or registrant required to make a report pursuant to 4.51.1 shall, within 30 days after

making the telephone report, make a written report to the Department setting forth the following

information:

4.51.2.1

A description of the licensed or registered source of radiation involved, including,

for radioactive material, the kind, quantity, and chemical and physical form; and, for

radiation machines, the manufacturer, model and serial number, type and maximum

energy of radiation emitted;

4.51.2.2

A description of the circumstances under which the loss or theft occurred; and

Hazardous Materials and Waste Management

34

4.51.2.3

A statement of disposition, or probable disposition, of the licensed or registered

source of radiation involved; and

4.51.2.4

Exposures of individuals to radiation, circumstances under which the exposures

occurred, and the possible total effective dose equivalent to persons in unrestricted

areas; and

4.51.2.5

Actions that have been taken, or will be taken, to recover the source of radiation;

and

4.51.2.6

Procedures or measures that have been, or will be, adopted to ensure against a

recurrence of the loss or theft of licensed or registered sources of radiation.

4.51.3 Subsequent to filing the written report, the licensee or registrant shall also report additional

substantive information on the loss or theft within 30 days after the licensee or registrant learns of

such information.

4.51.4 The licensee or registrant shall prepare any report filed with the Department pursuant to 4.51 so

that names of individuals who may have received exposure to radiation are stated in a separate

and detachable portion of the report.

4.52

Notification of Incidents.

4.52.1 Immediate Notification.

Notwithstanding other requirements for notification, each licensee or registrant shall notify the

Department as soon as possible but not later than 4 hours after the discovery of an event:

4.52.1.1

Involving a source of radiation possessed by the licensee or registrant that may

have caused or threatens to cause any of the following conditions:

(1)

An individual to receive:

(a)

A total effective dose equivalent of 0.25 Sv (25 rem) or more; or

(b)

A lens dose equivalent of 0.75 Sv (75 rem) or more; or

(c)

A shallow dose equivalent to the skin or extremities or a total organ dose

equivalent of 2.5 Gy (250 rad) or more; or

(2)

The release of radioactive material, inside or outside of a restricted area, so that,

had an individual been present for 24 hours, the individual could have received

an intake five times the occupational ALI. This provision does not apply to

locations where personnel are not normally stationed during routine operations,

such as hot cells or process enclosures.

4.52.1.2

That prevents immediate protective actions necessary to avoid exposures to

radiation and/or radioactive materials that could exceed regulatory limits, or releases of

licensed material that could exceed regulatory limits (events may include fires,

explosions, toxic gas releases, etc.).

4.52.2 Twenty-Four Hour Notification.

Each licensee or registrant shall, within 24 hours of discovery of the event, report to the

Department:

Hazardous Materials and Waste Management

35

4.52.2.1

Each event involving loss of control of a licensed or registered source of radiation

possessed by the licensee or registrant that may have caused, or threatens to cause, any

of the following conditions:

(1)

An individual to receive, in a period of 24 hours:

(a)

A total effective dose equivalent exceeding 0.05 Sv (5 rem); or

(b)

A lens dose equivalent exceeding 0.15 Sv (15 rem); or

(c)

A shallow dose equivalent to the skin or extremities or a total organ dose

equivalent exceeding 0.5 Sv (50 rem); or

(2)

The release of radioactive material, inside or outside of a restricted area, so that,

had an individual been present for 24 hours, the individual could have received

an intake in excess of one occupational ALI. This provision does not apply to

locations where personnel are not normally stationed during routine operations,

such as hot-cells or process enclosures.

4.52.2.2

An unplanned contamination event that:

(1)

Requires access to the contaminated area, by workers or the public, to be

restricted for more than 24 hours by imposing additional radiological controls or

by prohibiting entry into the area;

(2)

Involves a quantity of material greater than five times the lowest annual limit on

intake specified in Appendix 4B for the material; and

(3)

Has access to the area restricted for a reason other than to allow isotopes with a

half-life of less than 24 hours to decay prior to decontamination.

4.52.2.3

An event in which equipment is disabled or fails to function as designed when:

(1)

The equipment is required by regulation or license condition to prevent releases

exceeding regulatory limits, to prevent exposures to radiation and/or radioactive

materials exceeding regulatory limits, or to mitigate the consequences of an

accident; and

(2)

The equipment is required to be available and operable when it is disabled or

fails to function during the event; and

(3)

No redundant equipment is available and operable to perform the required safety

function.

4.52.2.4

An event that requires unplanned medical treatment at a medical facility of an

individual whose body or clothing is contaminated with spreadable radioactive material.

4.52.2.5

An unplanned fire or explosion damaging any licensed material or any device,

container, or equipment containing licensed material when:

(1)

The quantity of material involved is greater than five times the lowest annual limit

on intake specified in Appendix 4B for the material; and

(2)

The damage affects the integrity of the licensed material or its container.

Hazardous Materials and Waste Management

36

4.53

Preparation and Submission of Reports.

4.53.1 Reports made by licensees or registrants in response to the requirements of 4.52, must be made

as follows:

4.53.1.1

Licensees or registrants shall make the reports required by 4.52.1 and 4.52.2 to

the Department by telephone. To the extent that the information is available at the time of

notification, the information provided in these reports must include:

(1)

The caller's name and call back telephone number;

(2)

A description of the event including date and time;

(3)

The exact location of the event;

(4)

The isotopes, quantities, and chemical and physical form of the licensed material

involved; and

(5)

Any personnel radiation exposure data available.

4.53.1.2

Each licensee or registrant who makes a report required by 4.52.1 or 4.52.2 shall

submit a written follow-up report to the Department pursuant to 4.53.3 within 30 days of

the initial report. Written reports prepared pursuant to other regulations may be submitted

to fulfill this requirement if the reports contain all of the necessary information and the

appropriate distribution is made.

4.53.1.3

The provisions of 4.52 do not apply to doses that result from planned special

exposures, provided such doses are within the limits for planned special exposures and

are reported pursuant to 4.54.

4.53.2 Reports of Exposures, Radiation Levels, and Concentrations of Radioactive Material Exceeding

the Constraints or Limits.

In addition to the notification required by 4.52, each licensee or registrant shall submit a written

report to the Department within 30 days after learning of any of the following occurrences:

4.53.2.1

Incidents for which notification is required by 4.52; or

4.53.2.2

Doses in excess of any of the following:

(1)

The occupational dose limits for adults in 4.6; or

(2)

The occupational dose limits for a minor in 4.12; or

(3)

The limits for an embryo/fetus of a declared pregnant woman in 4.13; or

(4)

The limits for an individual member of the public in 4.14; or

(5)

Any applicable limit in the license or registration; or

(6)

The ALARA constraints for air emissions established under 4.5.4.

4.53.2.3

Levels of radiation or concentrations of radioactive material in:

(1)

A restricted area in excess of applicable limits in the license or registration; or

Hazardous Materials and Waste Management

37

(2)

An unrestricted area in excess of 10 times the applicable limit set forth in Part 4

or in the license or registration, whether or not involving exposure of any

individual in excess of the limits in 4.14; or

4.53.2.4

For licensees subject to the provisions of U.S. Environmental Protection

Agency's generally applicable environmental radiation standards in 40 CFR 190, July 1,

2004, levels of radiation or releases of radioactive material in excess of those standards,

or of license conditions related to those standards.

4.53.3 Contents of Written Reports.

4.53.3.1

Each report required by 4.53.1.2 or 4.53.2 shall include the following, as

appropriate:

(1)

A description of the event, including the possible cause and the manufacturer

and model number (if applicable) of any equipment that failed or malfunctioned;

(2)

The exact location of the event;

(3)

The isotopes, quantities, and chemical and physical form of the licensed material

involved;

(4)

Date and time of the event;

(5)

The results of any evaluations or assessments, including:

(a)

Estimates of each individual's dose;

(b)

The levels of radiation and concentrations of radioactive material

involved;

(c)

The cause of the elevated exposures, dose rates, or concentrations; and

(d)

Corrective steps taken or planned to ensure against a recurrence,

including the schedule for achieving conformance with applicable limits,

ALARA constraints, generally applicable environmental standards, and

associated license or registration conditions.

4.53.3.2

Each report filed pursuant to 4.53 shall include for each occupationally

overexposed individual exposed: the name, Social Security account number, and date of

birth. With respect to the limit for the embryo/fetus in 4.13, the identifiers should be those

of the declared pregnant woman. The report shall be prepared so that this information is

stated in a separate and detachable portion of the report and must be clearly labeled

“Privacy Act Information: Not for Public Disclosure”.

4.54

Reports of Planned Special Exposures.

4.54.1 The licensee or registrant shall submit a written report to the Department within 30 days following

any planned special exposure conducted in accordance with 4.11, informing the Department that

a planned special exposure was conducted and indicating the date the planned special exposure

occurred and the information required by 4.45.

Hazardous Materials and Waste Management

38

4.55

Reports of Transactions Involving Nationally Tracked Sources.

4.55.1 Each licensee who manufactures, transfers, receives, disassembles, or disposes of a nationally

tracked source shall complete and submit a National Source Tracking Transaction Report as

specified in 4.55.1.1 through 4.55.1.5 for each type of transaction.

4.55.1.1

Each licensee who manufactures a nationally tracked source shall complete and

submit a National Source Tracking Report. The report must include the following

information:

(1)

The name, address, and license number of the reporting licensee;

(2)

The name of the individual preparing the report;

(3)

The manufacturer, model, and serial number of the source;

(4)

The radioactive material in the source;

(5)

The initial source strength in becquerels (curies) at the time of manufacture;

and

(6)

The manufacture date of the source.

4.55.1.2

Each licensee that transfers a nationally tracked source to another person shall

complete and submit a National Source Tracking Transaction Report. The report must

include the following information:

(1)

The name, address, and license number of the reporting licensee;

(2)

The name of the individual preparing the report;

(3)

The name and license number of the recipient facility and the shipping address;

(4)

The manufacturer, model, and serial number of the source or, if not available,

other information to uniquely identify the source;

(5)

The radioactive material in the source;

(6)

The initial or current source strength in becquerels (curies);

(7)

The date for which the source strength is reported;

(8)

The shipping date;

(9)

The estimated arrival date;

and

(10)

For nationally tracked sources transferred as waste under a Uniform Low-Level

Radioactive Waste Manifest, the waste manifest number and the container

identification of the container with the nationally tracked source.

Hazardous Materials and Waste Management

39

4.55.1.3

Each licensee that receives a nationally tracked source shall complete and

submit a National Source Tracking Transaction Report. The report must include the

following information:

(1)

The name, address, and license number of the reporting licensee;

(2)

The name of the individual preparing the report;

(3)

The name, address, and license number of the person that provided the source;

(4)

The manufacturer, model, and serial number of the source or, if not available,

other information to uniquely identify the source;

(5)

The radioactive material in the source;

(6)

The initial or current source strength in becquerels (curies);

(7)

The date for which the source strength is reported;

(8)

The date of receipt;

and

(9)

For material received under a Uniform Low-Level Radioactive Waste Manifest,

the waste manifest number and the container identification with the nationally

tracked source.

4.55.1.4

Each licensee that disassembles a nationally tracked source shall complete and

submit a National Source Tracking Transaction Report. The report must include the

following information:

(1)

The name, address, and license number of the reporting licensee;

(2)

The name of the individual preparing the report;

(3)

The manufacturer, model, and serial number of the source or, if not available,

other information to uniquely identify the source;

(4)

The radioactive material in the source;

(5)

The initial or current source strength in becquerels (curies);

(6)

The date for which the source strength is reported;

(7)

The disassemble date of the source.

4.55.1.5

Each licensee who disposes of a nationally tracked source shall complete and

submit a National Source Tracking Transaction Report. The report must include the

following information:

(1)

The name, address, and license number of the reporting licensee;

(2)

The name of the individual preparing the report;

(3)

The waste manifest number;

Hazardous Materials and Waste Management

40

(4)

The container identification with the nationally tracked source.

(5)

The date of disposal;

and

(6)

The method of disposal.

4.55.1.6

The reports discussed in 4.55.1.1 through 4.55.1.5 must be submitted by the

close of the next business day after the transaction. A single report may be submitted for

multiple sources and transactions. The reports must be submitted to the National Source

Tracking System by using:

(1)

The on-line National Source Tracking System;

(2)

Electronically using a computer readable format;

(3)

By facsimile;

(4)

By mail to the address on the National Source Tracking Transaction Report Form

(NRC Form 748); or

(5)

By telephone with followup by facsimile or mail.

4.55.2 Each licensee shall correct any error in previously filed reports or file a new report for any missed

transaction within 5 business days of the discovery of the error or missed transaction. Such errors

may be detected by a variety of methods such as administrative reviews or by physical

inventories required by regulation. In addition, each licensee shall reconcile the inventory of

nationally tracked sources possessed by the licensee against that licensee’s data in the National

Source Tracking System. The reconciliation must be conducted during the month of January in

each year. The reconciliation process must include resolving any discrepancies between the

National Source Tracking System and the actual inventory by filing the reports identified by

4.55.1.1 through 4.55.1.5. By January 31 of each year, each licensee must submit to the National

Source Tracking System confirmation that the data in the National Source Tracking System is

correct.

4.56

Reports of Individual Monitoring.

4.56.1 This section applies to each person licensed or registered by the Department to:

4.56.1.1

Possess or use sources of radiation for purposes of industrial radiography

pursuant to Parts 3 and 5 of these regulations; or

4.56.1.2

Receive radioactive waste from other persons for disposal pursuant to Part 14 of

these regulations; or

4.56.1.3

Possess or use at any time, for processing or manufacturing for distribution

pursuant to Part 3 or 7 of these regulations, radioactive material in quantities exceeding

any one of the following quantities:

Hazardous Materials and Waste Management

41

Radionuclide

Activity

7

Activity

7

Ci

GBq

Cesium-137

1

37

Cobalt-60

1

37

Gold-198

100

3,700

Iodine-131

1

37

Iridium-192

10

370

Krypton-85

1,000

37,000

Promethium-147

10

370

Technetium-99m

1,000

37,000

7 The Department may require as a license condition, or by rule, regulation, or order pursuant to 1.9, reports from licensees or

registrants who are licensed or registered to use radionuclides not on this list, in quantities sufficient to cause comparable radiation

levels.

4.56.2 Each licensee or registrant in a category listed in 4.56.1 shall submit an annual report to the

Department of the results of individual monitoring carried out by the licensee or registrant for each

individual for whom monitoring was required by 4.18 during that year. The licensee or registrant

may include additional data for individuals for whom monitoring was provided but not required.

The licensee or registrant shall use Department Form R-17 or equivalent or Department-

approved electronic media containing all the information required by Department Form R-17.

4.56.3 The licensee or registrant shall file the report required by 4.56.2, covering the preceding year, on

or before April 30 of each year.

4.57

Notifications and Reports to Individuals.

4.57.1 Requirements for notification and reports to individuals of exposure to radiation or radioactive

material are specified in 10.4 of these regulations.

4.57.2 When a licensee or registrant is required pursuant to 4.53.2 or 4.54 to report to the Department

any exposure of an identified occupationally exposed individual or an identified member of the

public, to radiation or radioactive material, the licensee or registrant shall also provide the

individual a report on his or her exposure data included in the report to the Department. Such

report shall be transmitted at a time not later than the transmittal to the Department, and shall

comply with the provisions of 10.4.1 of these regulations.

4.58

Reports of Leaking or Contaminated Sealed Sources.

4.58.1 The licensee or registrant shall file a report within 5 days with the Department if the test for

leakage or contamination indicates a sealed source is leaking or contaminated. The report shall

include the equipment involved, the test results and the corrective action taken.

ADDITIONAL REQUIREMENTS

4.59

Vacating Premises.

4.59.1 Each specific licensee or registrant shall, no less than 30 days before vacating or relinquishing

possession or control of premises which may have been contaminated with radioactive material

as a result of the licensee's or registrant's activities, notify the Department in writing of intent to

vacate. When deemed necessary by the Department, the licensee shall decontaminate the

premises in such a manner as the Department may specify.

Hazardous Materials and Waste Management

42

4.60

Permissible Levels of Radioactive Material in Uncontrolled Areas.

4.60.1 Plutonium. Contamination of the soil in excess of 2.0 disintegrations per minute (0.03 Bq) of

plutonium per gram of dry soil or square centimeter of surface area (0.01 microcurie [370 Bq] per

square meter) presents a sufficient hazard to the public health to require the utilization of special

techniques of construction upon property so contaminated. Evaluation of proposed control

techniques shall be available from the Department upon request.

4.61

Radiological Criteria For License Termination.

4.61.1 The criteria in this section apply to the decommissioning of facilities licensed under Parts 3, 5, 7,

14, 16, and 19 of these regulations. For low-level waste disposal facilities licensed under Part 14,

the criteria apply only to the ancillary surface facilities that support radioactive waste disposal

activities.

4.61.1.1

The criteria in this section do not apply to uranium and thorium recovery facilities

already subject to Appendix A of Part 18; uranium solution extraction facilities; sites

which have been decommissioned and the license terminated prior to July 1, 1999; or

sites which submitted a decommissioning plan prior to July 1, 2000 and received

Department approval of that decommissioning plan prior to July 1, 2001.

4.61.1.2

When calculating the TEDE to the average member of the critical group, the

licensee shall determine the peak annual TEDE expected within the first 1000 years after

decommissioning. In accordance with 1.5.1, the Department may authorize the licensee

to exclude dose contributions from the inhalation of radon and its decay products when

calculating TEDE.

4.61.1.3

Determination of dose and residual radioactivity levels which are as low as

reasonably achievable (ALARA) must take into account consideration of any detriments,

such as deaths from transportation accidents, expected to potentially result from

decontamination and waste disposal.

4.61.2 Radiological Criteria For Unrestricted Use.

A site will be considered acceptable for license termination under conditions of unrestricted use if

the residual radioactivity that is distinguishable from background radiation results in a TEDE to an

average member of the critical group that does not exceed 0.25 mSv per year (25 mrem/y),

including that from groundwater sources of drinking water, and the residual radioactivity has been

reduced to levels that are ALARA.

4.61.3 Radiological Criteria For Restricted Use.

A site will be considered acceptable for license termination under restricted conditions if:

4.61.3.1

The licensee can demonstrate that further reductions in residual radioactivity

necessary to comply with the provisions of 4.61.2 would result in net public or

environmental harm or were not being made because the residual levels of contamination

associated with restricted conditions are ALARA. Determination of the levels which are

ALARA must take into consideration any detriments, such as traffic accidents, expected

to potentially result from decontamination and waste disposal;

4.61.3.2

The licensee has made provisions for durable, legally enforceable institutional

controls which provide reasonable assurance that the TEDE from residual radioactivity

distinguishable from background to the average member of the critical group will not

exceed 0.25 mSv per year (25 mrem/y).

Hazardous Materials and Waste Management

43

4.61.3.3

The licensee has provided sufficient financial assurance to enable an

independent third party, including a governmental custodian of a site, to assume and

carry out responsibilities for any necessary control and maintenance of the site.

Acceptable financial assurance mechanisms are:

(1)

Funds placed into an account segregated from the licensee’s assets and outside

the licensee’s administrative control as described in Part 3, Section 3.9.5.4(2)(a);

(2)

In the case of Federal, State, or local Government licensees, a statement of

intent containing a cost estimate for decommissioning and indicating that funds

for decommissioning will be obtained when necessary; or

(3)

When a governmental entity is assuming custody and ownership of a site, an

arrangement that is deemed acceptable by such governmental entity; and

4.61.3.4

Residual radioactivity at the site has been reduced so that if the institutional

controls were no longer in effect, there is reasonable assurance that the TEDE from

residual radioactivity distinguishable from background to the average member of the

critical group is ALARA and would not exceed either:

(1)

1 mSv per year (100 mrem/y); or

(2)

5 mSv per year (500 mrem/y), provided the licensee:

(a)

demonstrates that further reductions in residual radioactivity necessary

to comply with the 1-mSv-per-year (100 mrem/y) value of this paragraph

are not technically achievable, would be prohibitively expensive, or would

result in net public or environmental harm.

4.61.4 Alternate Criteria For License Termination.

4.61.4.1

The Department may terminate a license using alternate criteria greater than the

dose criterion of 4.61.2 or 4.61.3.2, if:

(1)

The licensee has performed an analysis for possible sources of exposure to

radiation which provides assurance that public health and safety would continue

to be protected, and that it is unlikely the TEDE to an average member of the

critical group from all radiation that is distinguishable from background radiation,

other than medical, would be more than 1 mSv per year (100 mrem/y);

(2)

The licensee has employed, to the extent practical, restrictions on site use which

minimize exposures at the site in accordance with the provisions of 4.61.3;

(3)

The licensee has reduced doses to levels which are ALARA; and

(4)

Has provided sufficient financial assurance in the form of a trust fund to enable

an independent third party, including a governmental custodian of a site, to

assume and carry out responsibilities for any necessary control and maintenance

of the site.

Hazardous Materials and Waste Management

44

PART 4, APPENDIX 4A:

ASSIGNED PROTECTION FACTORS FOR RESPIRATORS

Operating Mode

Assigned

Protection

Factors

I. Air purifying respirators [particulateb only]c:

Filtering facepiece disposable

Negative pressure

(d)

Facepiece, halfe

Negative pressure

10

Facepiece, full

Negative pressure

100

Facepiece, half

Powered air-purifying respirators

50

Facepiece, full

Powered air-purifying respirators

1000

Helmet/hood

Powered air-purifying respirators

1000

Facepiece, loose-fitting

Powered air-purifying respirators

25

II. Atmosphere supplying respirators

[particulate, gases and vaporsf]:

1. Air-line respirator:

Facepiece, half

Demand

10

Facepiece, half

Continuous flow

50

Facepiece, half

Pressure demand

50

Facepiece, full

Demand

100

Facepiece, full

Continuous flow

1000

Facepiece, full

Pressure demand

1000

Helmet/hood

Continuous flow

1000

Facepiece, loose-fitting

Continuous flow

25

Suit

Continuous flow

(g)

2. Self-contained breathing apparatus

(SCBA):

Facepiece, full

Demand

h 100

Facepiece, full

Pressure demand

i 10,000

Facepiece, full

Demand, recirculating

h 100

Facepiece, full

Positive pressure recirculating

i 10,000

III. Combination respirators:

Any combination of air-purifying and

atmosphere-supplying respirators

Assigned protection factor for

type and mode of operation as

listed above.

a These assigned protection factors apply only in a respiratory protection program that meets the requirements of this part. They are

applicable only to airborne radiological hazards and may not be appropriate to circumstances when chemical or other respiratory

hazards exist instead of, or in addition to, radioactive hazards. Selection and use of respirators for such circumstances must also

comply with department of labor regulations.

Radioactive contaminants for which the concentration values in Table 4B1, Column 3 of Appendix 4B are based on internal dose

due to inhalation may, in addition, present external exposure hazards at higher concentrations. Under these circumstances,

limitations on occupancy may have to be governed by external dose limits.

b Air-purifying respirators with APF <100 must be equipped with particulate filters that are at least 95 percent efficient. Air-purifying

respirators with APF = 100 must be equipped with particulate filters that are at least 99 percent efficient. Air-purifying respirators with

APFs > 100 must be equipped with particulate filters that are at least 99.97 percent efficient.

c The licensee may apply to the commission for the use of an APF greater than 1 for sorbent cartridges as protection against

airborne radioactive gases and vapors (e.g., radioiodine).

Hazardous Materials and Waste Management

45

d Licensees may permit individuals to use this type of respirator who have not been medically screened or fit tested on the device

provided that no credit be taken for their use in estimating intake or dose. It is also recognized that it is difficult to perform an

effective positive or negative pressure pre-use user seal check on this type of device. All other respiratory protection program

requirements listed in 4.24.1 apply. An assigned protection factor has not been assigned for these devices. However, an APF equal

to 10 may be used if the licensee can demonstrate a fit factor of at least 100 by use of a validated or evaluated, qualitative or

quantitative fit test.

e Under-chin type only. No distinction is made in this appendix between elastomeric half-masks with replaceable cartridges and

those designed with the filter medium as an integral part of the facepiece (e.g., disposable or reusable disposable). Both types are

acceptable so long as the seal area of the latter contains some substantial type of seal-enhancing material such as rubber or plastic,

the two or more suspension straps are adjustable, the filter medium is at least 95 percent efficient and all other requirements of this

part are met.

f The assigned protection factors for gases and vapors are not applicable to radioactive contaminants that present an absorption or

submersion hazard. For tritium oxide vapor, approximately one-third of the intake occurs by absorption through the skin so that an

overall protection factor of 3 is appropriate when atmosphere-supplying respirators are used to protect against tritium oxide.

Exposure to radioactive noble gases is not considered a significant respiratory hazard, and protective actions for these

contaminants should be based on external (submersion) dose considerations.

g No National Institute of Occupational Safety and Health (NIOSH) approval schedule is currently available for atmosphere

supplying suits. This equipment may be used in an acceptable respiratory protection program as long as all the other minimum

program requirements, with the exception of fit testing, are met (that is, 4.24.1).

h The licensee should implement institutional controls to assure that these devices are not used in areas immediately dangerous to

life or health (IDLH).

i This type of respirator may be used as an emergency device in unknown concentrations for protection against inhalation hazards.

External radiation hazards and other limitations to permitted exposure such as skin absorption shall be taken into account in these

circumstances. This device may not be used by any individual who experiences perceptible outward leakage of breathing gas while

wearing the device.

Hazardous Materials and Waste Management

46

PART 4, APPENDIX 4B:

ANNUAL LIMITS ON INTAKE (ALI) AND DERIVED AIR

CONCENTRATIONS (DAC) OF RADIONUCLIDES FOR OCCUPATIONAL EXPOSURE;

EFFLUENT CONCENTRATIONS; CONCENTRATIONS FOR RELEASE TO SANITARY

SEWERAGE

Introduction

For each radionuclide, Table 4B1 indicates the chemical form which is to be used for selecting the

appropriate ALI or DAC value. The ALIs and DACs for inhalation are given for an aerosol with an activity

median aerodynamic diameter (AMAD) of 1 µm, micron, and for three classes (D, W, Y) of radioactive

material, which refer to their retention (approximately days, weeks or years) in the pulmonary region of

the lung. This classification applies to a range of clearance half times for D if less than 10 days, for W

from 10 to 100 days, and for Y greater than 100 days. Table 4B2 provides concentration limits for

airborne and liquid effluents released to the general environment. Table 4B3 provides concentration limits

for discharges to sanitary sewerage.

Note:

The values in Table 4B1, Table 4B2, and Table 4B3 are presented in the computer “E” notation. In this

notation a value of 6E-02 represents a value of 6 x 10-2 or 0.06, 6E+2 represents 6 x 102 or 600, and

6E+0 represents 6 x 100 or 6.

Table 4B1 “Occupational Values”

Note that the columns in Table 4B1 of this appendix captioned “Oral Ingestion ALI,” “Inhalation ALI,” and

“DAC,” are applicable to occupational exposure to radioactive material.

The ALIs in this appendix are the annual intakes of given radionuclide by “reference man” which would

result in either (1) a committed effective dose equivalent of 0.05 Sv (5 rem), stochastic ALI, or (2) a

committed dose equivalent of 0.5 Sv (50 rem) to an organ or tissue, non-stochastic ALI. The stochastic

ALIs were derived to result in a risk, due to irradiation of organs and tissues, comparable to the risk

associated with deep dose equivalent to the whole body of 0.05 Sv (5 rem). The derivation includes

multiplying the committed dose equivalent to an organ or tissue by a weighting factor, wT. This weighting

factor is the proportion of the risk of stochastic effects resulting from irradiation of the organ or tissue, T,

to the total risk of stochastic effects when the whole body is irradiated uniformly. The values of wT are

listed under the definition of weighting factor in 4.3. The non-stochastic ALIs were derived to avoid non-

stochastic effects, such as prompt damage to tissue or reduction in organ function.

A value of wT= 0.06 is applicable to each of the five organs or tissues in the “remainder” category

receiving the highest dose equivalents, and the dose equivalents of all other remaining tissues may be

disregarded. The following portions of the Gl tract — stomach, small intestine, upper large intestine, and

lower large intestine — are to be treated as four separate organs.

Note that the dose equivalents for an extremity, skin and lens of the eye are not considered in computing

the committed effective dose equivalent, but are subject to limits that must be met separately.

When an ALI is defined by the stochastic dose limit, this value alone is given. When an ALI is determined

by the non-stochastic dose limit to an organ, the organ or tissue to which the limit applies is shown, and

the ALI for the stochastic limit is shown in parentheses. Abbreviated organ or tissue designations are

used:

LLI wall = lower large intestine wall;

St. wall = stomach wall;

Hazardous Materials and Waste Management

47

Blad wall = bladder wall; and

Bone surf = bone surface.

The use of the ALIs listed first, the more limiting of the stochastic and non-stochastic ALIs, will ensure that

non-stochastic effects are avoided and that the risk of stochastic effects is limited to an acceptably low

value. If, in a particular situation involving a radionuclide for which the non-stochastic ALI is limiting, use

of that non-stochastic ALI is considered unduly conservative, the licensee may use the stochastic ALI to

determine the committed effective dose equivalent. However, the licensee shall also ensure that the 0.5

Sv (50 rem) dose equivalent limit for any organ or tissue is not exceeded by the sum of the external deep

dose equivalent plus the internal committed dose equivalent to that organ, not the effective dose. For the

case where there is no external dose contribution, this would be demonstrated if the sum of the fractions

of the nonstochastic ALIs (ALIns) that contribute to the committed dose equivalent to t he organ receiving

the highest dose does not exceed unity, that is, ∑ (intake (in µCi) of each radionuclide/ALIns) ≤ 1.0. If

there is an external deep dose equivalent contribution of Hd, then this sum must be less than 1 - (Hd/50),

instead of ≤ 1.0.

Note that the dose equivalents for an extremity, skin, and lens of the eye are not considered in computing

the committed effective dose equivalent, but are subject to limits that must be met separately.

The derived air concentration (DAC) values are derived limits intended to control chronic occupational

exposures. The relationship between the DAC and the ALI is given by:

DAC = ALI (in µCi)/(2000 hours per working year x 60 minutes/hour x 2 x 104 ml per minute) = (ALI/2.4 x

109) µCi/ml, where 2 x 104 ml is the volume of air breathed per minute at work by reference man under

working conditions of light work.

The DAC values relate to one of two modes of exposure: either external submersion or the internal

committed dose equivalents resulting from inhalation of radioactive materials. DACs based upon

submersion are for immersion in a semi-infinite cloud of uniform concentration and apply to each

radionuclide separately.

The ALI and DAC values include contributions to exposure by the single radionuclide named and any in-

growth of decay product radionuclides produced in the body by decay of the parent. However, intakes

that include both the parent and decay product radionuclides should be treated by the general method

appropriate for mixtures.

The values of ALI and DAC do not apply directly when the individual both ingests and inhales a

radionuclide, when the individual is exposed to a mixture of radionuclides by either inhalation or ingestion

or both, or when the individual is exposed to both internal and external irradiation. See 4.7. When an

individual is exposed to radioactive materials which fall under several of the translocation classifications

of the same radionuclide, such as, Class D, Class W, or Class Y, the exposure may be evaluated as if it

were a mixture of different radionuclides.

It should be noted that the classification of a compound as Class D, W, or Y is based on the chemical

form of the compound and does not take into account the radiological half-life of different radionuclides.

For this reason, values are given for Class D, W, and Y compounds, even for very short-lived

radionuclides.

Hazardous Materials and Waste Management

48

Table 4B2 “Effluent Concentrations”

The columns in Table 4B2 of this appendix captioned “Effluents,” “Air” and “Water” are applicable to the

assessment and control of dose to the public, particularly in the implementation of the provisions of 4.15.

The concentration values given in Columns 1 and 2 of Table 4B2 are equivalent to the radionuclide

concentrations which, if inhaled or ingested continuously over the course of a year, would produce a total

effective dose equivalent of 0.5 mSv (0.05 rem).

Consideration of non-stochastic limits has not been included in deriving the air and water effluent

concentration limits because non-stochastic effects are presumed not to occur at or below the dose levels

established for individual members of the public. For radionuclides, where the non-stochastic limit was

governing in deriving the occupational DAC, the stochastic ALI was used in deriving the corresponding

airborne effluent limit in Table 4B2. For this reason, the DAC and airborne effluent limits are not always

proportional as they were in Appendix A of Part D of the Eighth Edition of Volume I of the Suggested

State Regulations for Control of Radiation, April 2004.

The air concentration values listed in Table 4B2, Column 1, were derived by one of two methods. For

those radionuclides for which the stochastic limit is governing, the occupational stochastic inhalation ALI

was divided by 2.4 x 109, relating the inhalation ALI to the DAC, as explained above, and then divided by

a factor of 300. The factor of 300 includes the following components: a factor of 50 to relate the 0.05 Sv

(5 rem) annual occupational dose limit to the 0.1 rem limit for members of the public, a factor of 3 to

adjust for the difference in exposure time and the inhalation rate for a worker and that for members of the

public; and a factor of 2 to adjust the occupational values, derived for adults, so that they are applicable to

other age groups.

For those radionuclides for which submersion, that is external dose, is limiting, the occupational DAC in

Table 4B1, Column 3 was divided by 219. The factor of 219 is composed of a factor of 50, as described

above, and a factor of 4.38 relating occupational exposure for 2,000 hours per year to full-time exposure

(8,760 hours per year). Note that an additional factor of 2 for age considerations is not warranted in the

submersion case.

The water concentrations were derived by taking the most restrictive occupational stochastic oral

ingestion ALI and dividing by 7.3 x 107. The factor of 7.3 x 107 (ml) includes the following components: the

factors of 50 and 2 described above and a factor of 7.3 x 105 (ml) which is the annual water intake of

reference man.

Note 2 of this appendix provides groupings of radionuclides which are applicable to unknown mixtures of

radionuclides. These groupings, including occupational inhalation ALIs and DACs, air and water effluent

concentrations and releases to sewer, require demonstrating that the most limiting radionuclides in

successive classes are absent. The limit for the unknown mixture is defined when the presence of one of

the listed radionuclides cannot be definitely excluded as being present either from knowledge of the

radionuclide composition of the source or from actual measurements.

Table 4B3 “Releases to Sewerage”

The monthly average concentrations for release to sanitary sewerage are applicable to the provisions in

4.35. The concentration values were derived by taking the most restrictive occupational stochastic oral

ingestion ALI and dividing by 7.3 x 106 (ml). The factor of 7.3 x 106 (ml) is composed of a factor of 7.3 x

105 (ml), the annual water intake by reference man, and a factor of 10, such that the concentrations, if the

sewage released by the licensee were the only source of water ingested by a reference man during a

year, would result in a committed effective dose equivalent of 0.5 rem (5 mSv).Table 4B1, Table 4B2, and

Table 4B3

Hazardous Materials and Waste Management

49

Hazardous Materials and Waste Management

50

Hazardous Materials and Waste Management

51

Hazardous Materials and Waste Management

52

Hazardous Materials and Waste Management

53

Hazardous Materials and Waste Management

54

Hazardous Materials and Waste Management

55

Hazardous Materials and Waste Management

56

Hazardous Materials and Waste Management

57

Hazardous Materials and Waste Management

58

Hazardous Materials and Waste Management

59

Hazardous Materials and Waste Management

60

Hazardous Materials and Waste Management

61

Hazardous Materials and Waste Management

62

Hazardous Materials and Waste Management

63

Hazardous Materials and Waste Management

64

Hazardous Materials and Waste Management

65

Hazardous Materials and Waste Management

66

Hazardous Materials and Waste Management

67

Hazardous Materials and Waste Management

68

Hazardous Materials and Waste Management

69

Hazardous Materials and Waste Management

70

Hazardous Materials and Waste Management

71

Hazardous Materials and Waste Management

72

Hazardous Materials and Waste Management

73

Hazardous Materials and Waste Management

74

Hazardous Materials and Waste Management

75

Hazardous Materials and Waste Management

76

Hazardous Materials and Waste Management

77

Hazardous Materials and Waste Management

78

Hazardous Materials and Waste Management

79

Hazardous Materials and Waste Management

80

Hazardous Materials and Waste Management

81

Hazardous Materials and Waste Management

82

Hazardous Materials and Waste Management

83

Hazardous Materials and Waste Management

84

Hazardous Materials and Waste Management

85

Hazardous Materials and Waste Management

86

Hazardous Materials and Waste Management

87

Hazardous Materials and Waste Management

88

Hazardous Materials and Waste Management

89

Hazardous Materials and Waste Management

90

Hazardous Materials and Waste Management

91

Hazardous Materials and Waste Management

92

Hazardous Materials and Waste Management

93

Hazardous Materials and Waste Management

94

Hazardous Materials and Waste Management

95

Hazardous Materials and Waste Management

96

Hazardous Materials and Waste Management

97

Hazardous Materials and Waste Management

98

Hazardous Materials and Waste Management

99

Hazardous Materials and Waste Management

100

Hazardous Materials and Waste Management

101

Hazardous Materials and Waste Management

102

Hazardous Materials and Waste Management

103

Hazardous Materials and Waste Management

104

Hazardous Materials and Waste Management

105

Hazardous Materials and Waste Management

106

Hazardous Materials and Waste Management

107

Hazardous Materials and Waste Management

108

Hazardous Materials and Waste Management

109

Hazardous Materials and Waste Management

110

Hazardous Materials and Waste Management

111

Hazardous Materials and Waste Management

112

Hazardous Materials and Waste Management

113

LIST OF ELEMENTS

Name

Atomic Symbol

Atomic Number

Actinium

Ac

89

Aluminum

Al

13

Americium

Am

95

Antimony

Sb

51

Argon

Ar

18

Arsenic

As

33

Astatine

At

85

Barium

Ba

56

Berkelium

Bk

97

Beryllium

Be

4

Bismuth

Bi

83

Bromine

Br

35

Cadmium

Cd

48

Calcium

Ca

20

Californium

Cf

98

Carbon

C

6

Cerium

Ce

58

Cesium

Cs

55

Chlorine

Cl

17

Chromium

Cr

24

Cobalt

Co

27

Copper

Cu

29

Curium

Cm

96

Dysprosium

Dy

66

Einsteinium

Es

99

Erbium

Er

68

Europium

Eu

63

Fermium

Fm

100

Fluorine

F

9

Francium

Fr

87

Gadolinium

Gd

64

Gallium

Ga

31

Germanium

Ge

32

Gold

Au

79

Hafnium

Hf

72

Holmium

Ho

67

Hydrogen

H

1

Indium

In

49

Iodine

I

53

Iridium

Ir

77

Iron

Fe

26

Krypton

Kr

36

Lanthanum

La

57

Lead

Pb

82

Lutetium

Lu

71

Magnesium

Mg

12

Manganese

Mn

25

Mendelevium

Md

101

Mercury

Hg

80

Molybdenum

Mo

42

Neodymium

Nd

60

Neptunium

Np

93

Nickel

Ni

28

Hazardous Materials and Waste Management

114

Name

Atomic Symbol

Atomic Number

Niobium

Nb

41

Nitrogen

N

7

Osmium

Os

76

Oxygen

O

8

Palladium

Pd

46

Phosphorus

P

15

Platinum

Pt

78

Plutonium

Pu

94

Polonium

Po

84

Potassium

K

19

Praseodymium

Pr

59

Promethium

Pm

61

Protactinium

Pa

91

Radium

Ra

88

Radon

Rn

86

Rhenium

Re

75

Rhodium

Rh

45

Rubidium

Rb

37

Ruthenium

Ru

44

Samarium

Sm

62

Scandium

Sc

21

Selenium

Se

34

Silicon

Si

14

Silver

Ag

47

Sodium

Na

11

Strontium

Sr

38

Sulfur

S

16

Tantalum

Ta

73

Technetium

Tc

43

Tellurium

Te

52

Terbium

Tb

65

Thallium

Tl

81

Thorium

Th

90

Thulium

Tm

69

Tin

Sn

50

Titanium

Ti

22

Tungsten

W

74

Uranium

U

92

Vanadium

V

23

Xenon

Xe

54

Ytterbium

Yb

70

Yttrium

Y

39

Zinc

Zn

30

Zirconium

Zr

40

Hazardous Materials and Waste Management

115

PART 4, APPENDIX 4C:

QUANTITIES OF LICENSED OR REGISTERED MATERIAL

REQUIRING LABELING

QUANTITIESj OF LICENSED OR REGISTERED MATERIAL REQUIRING LABELING

* To convert µCi to kBq, multiply the µCi value by 37.

Radionuclide

Abbreviation

Quantity (µCi)

Hydrogen-3

H-3

1,000

Beryllium-7

Be-7

1,000

Beryllium-10

Be-10

1

Carbon-11

C-11

1,000

Carbon-14

C-14

100

Fluorine-18

F-18

1,000

Sodium-22

Na-22

10

Sodium-24

Na-24

100

Magnesium-28

Mg-28

100

Aluminum-26

Al-26

10

Silicon-31

Si-31

1,000

Silicon-32

Si-32

1

Phosphorus-32

P-32

10

Phosphorus-33

P-33

100

Sulfur-35

S-35

100

Chlorine-36

Cl-36

10

Chlorine-38

Cl-38

1,000

Chlorine-39

Cl-39

1,000

Argon-39

Ar-39

1,000

Argon-41

Ar-41

1,000

Potassium-40

K-40

100

Potassium-42

K-42

1,000

Potassium-43

K-43

1,000

Potassium-44

K-44

1,000

Potassium-45

K-45

1,000

Calcium-41

Ca-41

100

Calcium-45

Ca-45

100

Calcium-47

Ca-47

100

Scandium-43

Sc-43

1,000

Scandium-44m

Sc-44m

100

Scandium-44

Sc-44

100

Scandium-46

Sc-46

10

Hazardous Materials and Waste Management

116

Radionuclide

Abbreviation

Quantity (µCi)

Scandium-47

Sc-47

100

Scandium-48

Sc-48

100

Scandium-49

Sc-49

1,000

Titanium-44

Ti-44

1

Titanium-45

Ti-45

1,000

Vanadium-47

V-47

1,000

Vanadium-48

V-48

100

Vanadium-49

V-49

1,000

Chromium-48

Cr-48

1,000

Chromium-49

Cr-49

1,000

Chromium-51

Cr-51

1,000

Manganese-51

Mn-51

1,000

Manganese-52m

Mn-52m

1,000

Manganese-52

Mn-52

100

Manganese-53

Mn-53

1,000

Manganese-54

Mn-54

100

Manganese-56

Mn-56

1,000

Iron-52

Fe-52

100

Iron-55

Fe-55

100

Iron-59

Fe-59

10

Iron-60

Fe-60

1

Cobalt-55

Co-55

100

Cobalt-56

Co-56

10

Cobalt-57

Co-57

100

Cobalt-58m

Co-58m

1,000

Cobalt-58

Co-58

100

Cobalt-60m

Co-60m

1,000

Cobalt-60

Co-60

1

Cobalt-61

Co-61

1,000

Cobalt-62m

Co-62m

1,000

Nickel-56

Ni-56

100

Nickel-57

Ni-57

100

Nickel-59

Ni-59

100

Nickel-63

Ni-63

100

Nickel-65

Ni-65

1,000

Nickel-66

Ni-66

10

Copper-60

Cu-60

1,000

Copper-61

Cu-61

1,000

Copper-64

Cu-64

1,000

Hazardous Materials and Waste Management

117

Radionuclide

Abbreviation

Quantity (µCi)

Copper-67

Cu-67

1,000

Zinc-62

Zn-62

100

Zinc-63

Zn-63

1,000

Zinc-65

Zn-65

10

Zinc-69m

Zn-69m

100

Zinc-69

Zn-69

1,000

Zinc-71m

Zn-71m

1,000

Zinc-72

Zn-72

100

Gallium-65

Ga-65

1,000

Gallium-66

Ga-66

100

Gallium-67

Ga-67

1,000

Gallium-68

Ga-68

1,000

Gallium-70

Ga-70

1,000

Gallium-72

Ga-72

100

Gallium-73

Ga-73

1,000

Germanium-66

Ge-66

1,000

Germanium-67

Ge-67

1,000

Germanium-68

Ge-68

10

Germanium-69

Ge-69

1,000

Germanium-71

Ge-71

1,000

Germanium-75

Ge-75

1,000

Germanium-77

Ge-77

1,000

Germanium-78

Ge-78

1,000

Arsenic-69

As-69

1,000

Arsenic-70

As-70

1,000

Arsenic-71

As-71

100

Arsenic-72

As-72

100

Arsenic-73

As-73

100

Arsenic-74

As-74

100

Arsenic-76

As-76

100

Arsenic-77

As-77

100

Arsenic-78

As-78

1,000

Selenium-70

Se-70

1,000

Selenium-73m

Se-73m

1,000

Selenium-73

Se-73

100

Selenium-75

Se-75

100

Selenium-79

Se-79

100

Selenium-81m

Se-81m

1,000

Selenium-81

Se-81

1,000

Hazardous Materials and Waste Management

118

Radionuclide

Abbreviation

Quantity (µCi)

Selenium-83

Se-83

1,000

Bromine-74m

Br-74m

1,000

Bromine-74

Br-74

1,000

Bromine-75

Br-75

1,000

Bromine-76

Br-76

100

Bromine-77

Br-77

1,000

Bromine-80m

Br-80m

1,000

Bromine-80

Br-80

1,000

Bromine-82

Br-82

100

Bromine-83

Br-83

1,000

Bromine-84

Br-84

1,000

Krypton-74

Kr-74

1,000

Krypton-76

Kr-76

1,000

Krypton-77

Kr-77

1,000

Krypton-79

Kr-79

1,000

Krypton-81

Kr-81

1,000

Krypton-83m

Kr-83m

1,000

Krypton-85m

Kr-85m

1,000

Krypton-85

Kr-85

1,000

Krypton-87

Kr-87

1,000

Krypton-88

Kr-88

1,000

Rubidium-79

Rb-79

1,000

Rubidium-81m

Rb-81m

1,000

Rubidium-81

Rb-81

1,000

Rubidium-82m

Rb-82m

1,000

Rubidium-83

Rb-83

100

Rubidium-84

Rb-84

100

Rubidium-86

Rb-86

100

Rubidium-87

Rb-87

100

Rubidium-88

Rb-88

1,000

Rubidium-89

Rb-89

1,000

Strontium-80

Sr-80

100

Strontium-81

Sr-81

1,000

Strontium-83

Sr-83

100

Strontium-85m

Sr-85m

1,000

Strontium-85

Sr-85

100

Strontium-87m

Sr-87m

1,000

Strontium-89

Sr-89

10

Strontium-90

Sr-90

0.1

Hazardous Materials and Waste Management

119

Radionuclide

Abbreviation

Quantity (µCi)

Strontium-91

Sr-91

100

Strontium-92

Sr-92

100

Yttrium-86m

Y-86m

1,000

Yttrium-86

Y-86

100

Yttrium-87

Y-87

100

Yttrium-88

Y-88

10

Yttrium-90m

Y-90m

1,000

Yttrium-90

Y-90

10

Yttrium-91m

Y-91m

1,000

Yttrium-91

Y-91

10

Yttrium-92

Y-92

100

Yttrium-93

Y-93

100

Yttrium-94

Y-94

1,000

Yttrium-95

Y-95

1,000

Zirconium-86

Zr-86

100

Zirconium-88

Zr-88

10

Zirconium-89

Zr-89

100

Zirconium-93

Zr-93

1

Zirconium-95

Zr-95

10

Zirconium-97

Zr-97

100

Niobium-88

Nb-88

1,000

Niobium-89m (66 min)

Nb-89m

1,000

Niobium-89 (122 min)

Nb-89

1,000

Niobium-89

Nb-89

1,000

Niobium-90

Nb-90

100

Niobium-93m

Nb-93m

10

Niobium-94

Nb-94

1

Niobium-95m

Nb-95m

100

Niobium-95

Nb-95

100

Niobium-96

Nb-96

100

Niobium-97

Nb-97

1,000

Niobium-98

Nb-98

1,000

Molybdenum-90

Mo-90

100

Molybdenum-93m

Mo-93m

100

Molybdenum-93

Mo-93

10

Molybdenum-99

Mo-99

100

Molybdenum-101

Mo-101

1,000

Technetium-93m

Tc-93m

1,000

Technetium-93

Tc-93

1,000

Hazardous Materials and Waste Management

120

Radionuclide

Abbreviation

Quantity (µCi)

Technetium-94m

Tc-94m

1,000

Technetium-94

Tc-94

1,000

Technetium-96m

Tc-96

1,000

Technetium-96

Tc-96

100

Technetium-97m

Tc-97m

100

Technetium-97

Tc-97

1,000

Technetium-98

Tc-98

10

Technetium-99m

Tc-99m

1,000

Technetium-99

Tc-99

100

Technetium-101

Tc-101

1,000

Technetium-104

Tc-104

1,000

Ruthenium-94

Ru-94

1,000

Ruthenium-97

Ru-97

1,000

Ruthenium-103

Ru-103

100

Ruthenium-105

Ru-105

1,000

Ruthenium-106

Ru-106

1

Rhodium-99m

Rh-99m

1,000

Rhodium-99

Rh-99

100

Rhodium-100

Rh-100

100

Rhodium-101m

Rh-101m

1,000

Rhodium-101

Rh-101

10

Rhodium-102m

Rh-102m

10

Rhodium-102

Rh-102

10

Rhodium-103m

Rh-103m

1,000

Rhodium-105

Rh-105

100

Rhodium-106m

Rh-106m

1,000

Rhodium-107

Rh-107

1,000

Palladium-100

Pd-100

100

Palladium-101

Pd-101

1,000

Palladium-103

Pd-103

100

Palladium-107

Pd-107

10

Palladium-109

Pd-109

100

Silver-102

Ag-102

1,000

Silver-103

Ag-103

1,000

Silver-104m

Ag-104m

1,000

Silver-104

Ag-104

1,000

Silver-105

Ag-105

100

Silver-106m

Ag-106m

100

Silver-106

Ag-106

1,000

Hazardous Materials and Waste Management

121

Radionuclide

Abbreviation

Quantity (µCi)

Silver-108m

Ag-108m

1

Silver-110m

Ag-110m

10

Silver-111

Ag-111

100

Silver-112

Ag-112

100

Silver-115

Ag-115

1,000

Cadmium-104

Cd-104

1,000

Cadmium-107

Cd-107

1,000

Cadmium-109

Cd-109

1

Cadmium-113m

Cd-113m

0.1

Cadmium-113

Cd-113

100

Cadmium-115m

Cd-115m

10

Cadmium-115

Cd-115

100

Cadmium-117m

Cd-117m

1,000

Cadmium-117

Cd-117

1,000

Indium-109

In-109

1,000

Indium-110 (69.1 min.)

In-110

1,000

Indium-110 (4.9h)

In-110

1,000

Indium-111

In-111

100

Indium-112

In-112

1,000

Indium-113m

In-113m

1,000

Indium-114m

In-114m

10

Indium-115m

In-115m

1,000

Indium-115

In-115

100

Indium-116m

In-116m

1,000

Indium-117m

In-117m

1,000

Indium-117

In-117

1,000

Indium-119m

In-119m

1,000

Tin-110

Sn-110

100

Tin-111

Sn-111

1,000

Tin-113

Sn-113

100

Tin-117m

Sn-117m

100

Tin-119m

Sn-119m

100

Tin-121m

Sn-121m

100

Tin-121

Sn-121

1,000

Tin-123m

Sn-123m

1,000

Tin-123

Sn-123

10

Tin-125

Sn-125

10

Tin-126

Sn-126

10

Tin-127

Sn-127

1,000

Hazardous Materials and Waste Management

122

Radionuclide

Abbreviation

Quantity (µCi)

Tin-128

Sn-128

1,000

Antimony-115

Sb-115

1,000

Antimony-116m

Sb-116m

1,000

Antimony-116

Sb-116

1,000

Antimony-117

Sb-117

1,000

Antimony-118m

Sb-118m

1,000

Antimony-119

Sb-119

1,000

Antimony-120 (16 min.)

Sb-120

1,000

Antimony-120 (5.76d)

Sb-120

100

Antimony-122

Sb-122

100

Antimony-124m

Sb-124m

1,000

Antimony-124

Sb-124

10

Antimony-125

Sb-125

100

Antimony-126m

Sb-126m

1,000

Antimony-126

Sb-126

100

Antimony-127

Sb-127

100

Antimony-128 (10.4 min.)

Sb-128

1,000

Antimony-128 (9.01h)

Sb-128

100

Antimony-129

Sb-129

100

Antimony-130

Sb-130

1,000

Antimony-131

Sb-131

1,000

Tellurium-116

Te-116

1,000

Tellurium-121m

Te-121m

10

Tellurium-121

Te-121

100

Tellurium-123m

Te-123m

10

Tellurium-123

Te-123

100

Tellurium-125m

Te-125m

10

Tellurium-127m

Te-127m

10

Tellurium-127

Te-127

1,000

Tellurium-129m

Te-129m

10

Tellurium-129

Te-129

1,000

Tellurium-131m

Te-131m

10

Tellurium-131

Te-131

100

Tellurium-132

Te-132

10

Tellurium-133m

Te-133m

100

Tellurium-133

Te-133

1,000

Tellurium-134

Te-134

1,000

Iodine-120m

I-120m

1,000

Iodine-120

I-120

100

Hazardous Materials and Waste Management

123

Radionuclide

Abbreviation

Quantity (µCi)

Iodine-121

I-121

1,000

Iodine-123

I-123

100

Iodine-124

I-124

10

Iodine-125

I-125

1

Iodine-126

I-126

1

Iodine-128

I-128

1,000

Iodine-129

I-129

1

Iodine-130

I-130

10

Iodine-131

I-131

1

Iodine-132m

I-132m

100

Iodine-132

I-132

100

Iodine-133

I-133

10

Iodine-134

I-134

1,000

Iodine-135

I-135

100

Xenon-120

Xe-120

1,000

Xenon-121

Xe-121

1,000

Xenon-122

Xe-122

1,000

Xenon-123

Xe-123

1,000

Xenon-125

Xe-125

1,000

Xenon-127

Xe-127

1,000

Xenon-129m

Xe-129m

1,000

Xenon-131m

Xe-131m

1,000

Xenon-133m

Xe-133m

1,000

Xenon-133

Xe-133

1,000

Xenon-135m

Xe-135m

1,000

Xenon-135

Xe-135

1,000

Xenon-138

Xe-138

1,000

Cesium-125

Cs-125

1,000

Cesium-127

Cs-127

1,000

Cesium-129

Cs-129

1,000

Cesium-130

Cs-130

1,000

Cesium-131

Cs-131

1,000

Cesium-132

Cs-132

100

Cesium-134m

Cs-134m

1,000

Cesium-134

Cs-134

10

Cesium-135m

Cs-135m

1,000

Cesium-135

Cs-135

100

Cesium-136

Cs-136

10

Cesium-137

Cs-137

10

Hazardous Materials and Waste Management

124

Radionuclide

Abbreviation

Quantity (µCi)

Cesium-138

Cs-138

1,000

Barium-126

Ba-126

1,000

Barium-128

B-128

100

Barium-131m

Ba-131m

1,000

Barium-131

Ba-131

100

Barium-133m

Ba-133m

100

Barium-133

Ba-133

100

Barium-135m

Ba-135m

100

Barium-139

Ba-139

1,000

Barium-140

Ba-140

100

Barium-141

Ba-141

1,000

Barium-142

Ba-142

1,000

Lanthanum-131

La-131

1,000

Lanthanum-132

La-132

100

Lanthanum-135

La-135

1,000

Lanthanum-137

La-137

10

Lanthanum-138

La-138

100

Lanthanum-140

La-140

100

Lanthanum-141

La-141

100

Lanthanum-142

La-142

1,000

Lanthanum-143

La-143

1,000

Cerium-134

Ce-134

100

Cerium-135

Ce-135

100

Cerium-137m

Ce-137m

100

Cerium-137

Ce-137

1,000

Cerium-139

Ce-139

100

Cerium-141

Ce-141

100

Cerium-143

Ce-143

100

Cerium-144

Ce-144

1

Praseodymium-136

Pr-136

1,000

Praseodymium-137

Pr-137

1,000

Praseodymium-138m

Pe-138m

1,000

Praseodymium-139

Pe-139

1,000

Praseodymium-142m

Pe-142m

1,000

Praseodymium-142

Pe-142

100

Praseodymium-143

Pe-143

100

Praseodymium-144

Pe-144

1,000

Praseodymium-145

Pe-145

100

Praseodymium-147

Pe-147

1,000

Hazardous Materials and Waste Management

125

Radionuclide

Abbreviation

Quantity (µCi)

Neodymium-136

Nd-136

1,000

Neodymium-138

Nd-138

100

Neodymium-139m

Nd-139m

1,000

Neodymium-139

Nd-139

1,000

Neodymium-141

Nd-141

1,000

Neodymium-147

Nd-147

100

Neodymium-149

Nd-149

1,000

Neodymium-151

Nd-151

1,000

Promethium-141

Pm-141

1,000

Promethium-143

Pm-143

100

Promethium-144

Pm-144

10

Promethium-145

Pm-145

10

Promethium-146

Pm-146

1

Promethium-147

Pm-147

10

Promethium-148m

Pm-148m

10

Promethium-148

Pm-148

10

Promethium-149

Pm-149

100

Promethium-150

Pm-150

1,000

Promethium-151

Pm-151

100

Samarium-141m

Sm-141m

1,000

Samarium-141

Sm-141

1,000

Samarium-142

Sm-142

1,000

Samarium-145

Sm-145

100

Samarium-146

Sm-146

1

Samarium-147

Sm-147

100

Samarium-151

Sm-151

10

Samarium-153

Sm-153

100

Samarium-155

Sm-155

1,000

Samarium-156

Sm-156

1,000

Europium-145

Eu-145

100

Europium-146

Eu-146

100

Europium-147

Eu-147

100

Europium-148

Eu-148

10

Europium-149

Eu-149

100

Europium-150 (12.62h)

Eu-150

100

Europium-150 (34.2y)

Eu-150

1

Europium-152m

Eu-152m

100

Europium-152

Eu-152

1

Europium-154

Eu-154

1

Hazardous Materials and Waste Management

126

Radionuclide

Abbreviation

Quantity (µCi)

Europium-155

Eu-155

10

Europium-156

Eu-156

100

Europium-157

Eu-157

100

Europium-158

Eu-158

1,000

Gadolinium-145

Gd-145

1,000

Gadolinium-146

Gd-146

10

Gadolinium-147

Gd-147

100

Gadolinium-148

Gd-148

0.001

Gadolinium-149

Gd-149

100

Gadolinium-151

Gd-151

10

Gadolinium-152

Gd-152

100

Gadolinium-153

Gd-153

10

Gadolinium-159

Gd-159

100

Terbium-147

Tb-147

1,000

Terbium-149

Tb-149

100

Terbium-150

Tb-150

1,000

Terbium-151

Tb-151

100

Terbium-153

Tb-153

1,000

Terbium-154

Tb-154

100

Terbium-155

Tb-155

1,000

Terbium-156m (5.0h)

Tb-156m

1,000

Terbium-156m (24.4h)

Tb-156m

1,000

Terbium-156

Tb-156

100

Terbium-157

Tb-157

10

Terbium-158

Tb-158

1

Terbium-160

Tb-160

10

Terbium-161

Tb-161

100

Dysprosium-155

Dy-155

1,000

Dysprosium-157

Dy-157

1,000

Dysprosium-159

Dy-159

100

Dysprosium-165

Dy-165

1,000

Dysprosium-166

Dy-166

100

Holmium-155

Ho-155

1,000

Holmium-157

Ho-157

1,000

Holmium-159

Ho-159

1,000

Holmium-161

Ho-161

1,000

Holmium-162m

Ho-162m

1,000

Holmium-162

Ho-162

1,000

Holmium-164m

Hp-164m

1,000

Hazardous Materials and Waste Management

127

Radionuclide

Abbreviation

Quantity (µCi)

Holmium-164

Ho-164

1,000

Holmium-166m

Ho-166m

1

Holmium-166

Ho-166

100

Holmium-167

Ho-167

1,000

Erbium-161

Er-161

1,000

Erbium-165

Er-165

1,000

Erbium-169

Er-169

100

Erbium-171

Er-171

100

Erbium-172

Er-172

100

Thulium-162

Tm-162

1,000

Thulium-166

Tm-166

100

Thulium-167

Tm-167

100

Thulium-170

Tm-170

10

Thulium-171

Tm-171

10

Thulium-172

Tm-172

100

Thulium-173

Tm-173

100

Thulium-175

Tm-175

1,000

Ytterbium-162

Yb-162

1,000

Ytterbium-166

Yb-166

100

Ytterbium-167

Yb-167

1,000

Ytterbium-169

Yb-169

100

Ytterbium-175

Yb-175

100

Ytterbium-177

Yb-177

1,000

Ytterbium-178

Yb-178

1,000

Lutetium-169

Lu-169

100

Lutetium-170

Lu-170

100

Lutetium-171

Lu-171

100

Lutetium-172

Lu-172

100

Lutetium-173

Lu-173

10

Lutetium-174m

Lu-174m

10

Lutetium-174

Lu-174

10

Lutetium-176m

Lu-176m

1,000

Lutetium-176

Lu-176

100

Lutetium-177m

Lu-177m

10

Lutetium-177

Lu-177

100

Lutetium-178m

Lu-178m

1,000

Lutetium-178

Lu-178

1,000

Lutetium-179

Lu-179

1,000

Hafnium-170

Hf-170

100

Hazardous Materials and Waste Management

128

Radionuclide

Abbreviation

Quantity (µCi)

Hafnium-172

Hf-172

1

Hafnium-173

Hf-173

1,000

Hafnium-175

Hf-175

100

Hafnium-177m

Hf-177m

1,000

Hafnium-178m

Hf-178m

0.1

Hafnium-179m

Hf-179m

10

Hafnium-180m

Hf-180m

1,000

Hafnium-181

Hf-181

10

Hafnium-182m

Hf-182m

1,000

Hafnium-182

Hf-182

0.1

Hafnium-183

Hf-183

1,000

Hafnium-184

Hf-184

100

Tantalum-172

Ta-172

1,000

Tantalum-173

Ta-173

1,000

Tantalum-174

Ta-174

1,000

Tantalum-175

Ta-175

1,000

Tantalum-176

Ta-176

100

Tantalum-177

Ta-177

1,000

Tantalum-178

Ta-178

1,000

Tantalum-179

Ta-179

100

Tantalum-180m

Ta-180m

1,000

Tantalum-180

Ta-180

100

Tantalum-182m

Ta-182m

1,000

Tantalum-182

Ta-182

10

Tantalum-183

Ta-183

100

Tantalum-184

Ta-184

100

Tantalum-185

Ta-185

1,000

Tantalum-186

Ta-186

1,000

Tungsten-176

W-176

1,000

Tungsten-177

W-177

1,000

Tungsten-178

W-178

1,000

Tungsten-179

W-179

1,000

Tungsten-181

W-181

1,000

Tungsten-185

W-185

100

Tungsten-187

W-187

100

Tungsten-188

W-188

10

Rhenium-177

Re-177

1,000

Rhenium-178

Re-178

1,000

Rhenium-181

Re-181

1,000

Hazardous Materials and Waste Management

129

Radionuclide

Abbreviation

Quantity (µCi)

Rhenium-182 (12.7h)

Re-182

1,000

Rhenium-182 (64.0h)

Re-182

100

Rhenium-184m

Re-184m

10

Rhenium-184

Re-184

100

Rhenium-186m

Re-186m

10

Rhenium-186

Re-186

100

Rhenium-187

Re-187

1,000

Rhenium-188m

Re-188m

1,000

Rhenium-188

Re-188

100

Rhenium-189

Re-189

100

Osmium-180

Os-180

1,000

Osmium-181

Os-181

1,000

Osmium-182

Os-182

100

Osmium-185

Os-185

100

Osmium-189m

Os-189m

1,000

Osmium-191m

Os-191m

1,000

Osmium-191

Os-191

100

Osmium-193

Os-193

100

Osmium-194

Os-194

1

Iridium-182

Ir-182

1,000

Iridium-184

Ir-184

1,000

Iridium-185

Ir-185

1,000

Iridium-186

Ir-186

100

Iridium-187

Ir-187

1,000

Iridium-188

Ir-188

100

Iridium-189

Ir-189

100

Iridium-190m

Ir-190m

1,000

Iridium-190

Ir-190

100

Iridium-192 (73.8d)

Ir-192

1

Iridium-192m (1.4 min.)

Ir-192m

10

Iridium-194m

Ir-194m

10

Iridium-194

Ir-194

100

Iridium-195m

Ir-195m

1,000

Iridium-195

Ir-95

1,000

Platinum-186

Pt-186

1,000

Platinum-188

Pt-188

100

Platinum-189

Pt-189

1,000

Platinum-191

Pt-191

100

Platinum-193m

Pt-193m

100

Hazardous Materials and Waste Management

130

Radionuclide

Abbreviation

Quantity (µCi)

Platinum-193

Pt-193

1,000

Platinum-195m

Pt-195m

100

Platinum-197m

Pt-197m

1,000

Platinum-197

Pt-197

100

Platinum-199

Pt-199

1,000

Platinum-200

Pt-200

100

Gold-193

Au-193

1,000

Gold-194

Au-194

100

Gold-195

Au-195

10

Gold-198m

Au-198m

100

Gold-198

Au-198

100

Gold-199

Au-199

100

Gold-200m

Au-200m

100

Gold-200

Au-200

1,000

Gold-201

Au-201

1,000

Mercury-193m

Hg-193m

100

Mercury-193

Hg-193

1,000

Mercury-194

Hg-194

1

Mercury-195m

Hg-195m

100

Mercury-195

Hg-195

1,000

Mercury-197m

Hg-197m

100

Mercury-197

Hg-197

1,000

Mercury-199m

Hg-199m

1,000

Mercury-203

Hg-203

100

Thallium-194m

Tl-194m

1,000

Thallium-194

Tl-194

1,000

Thallium-195

Tl-195

1,000

Thallium-197

Tl-197

1,000

Thallium-198m

Tl-198m

1,000

Thallium-198

Tl-198

1,000

Thallium-199

Tl-199

1,000

Thallium-200

Tl-200

1,000

Thallium-201

Tl-201

1,000

Thallium-202

Tl-202

100

Thallium-204

Tl-204

100

Lead-195m

Pb-195m

1,000

Lead-198

Pb-198

1,000

Lead-199

Pb-199

1,000

Lead-200

Pb-200

100

Hazardous Materials and Waste Management

131

Radionuclide

Abbreviation

Quantity (µCi)

Lead-201

Pb-201

1,000

Lead-202m

Pb-202m

1,000

Lead-202

Pb-202

10

Lead-203

Pb-2023

1,000

Lead-205

Pb-205

100

Lead-209

Pb-209

1,000

Lead-210

Pb-210

0.01

Lead-211

Pb-211

100

Lead-212

Pb-212

1

Lead-214

Pb-214

100

Bismuth-200

Bi-200

1,000

Bismuth-201

Bi-201

1,000

Bismuth-202

Bi-202

1,000

Bismuth-203

Bi-203

100

Bismuth-205

Bi-205

100

Bismuth-206

Bi-206

100

Bismuth-207

Bi-207

10

Bismuth-210m

Bi-210m

0.1

Bismuth-210

Bi-210

1

Bismuth-212

Bi-212

10

Bismuth-213

Bi-213

10

Bismuth-214

Bi-214

100

Polonium-203

Po-203

1,000

Polonium-205

Po-205

1,000

Polonium-207

Po-207

1,000

Polonium-210

Po-210

0.1

Astatine-207

At-207

100

Astatine-211

At-211

10

Radon-220

Rn-220

1

Radon-222

Rn-222

1

Francium-222

Fr-222

100

Francium-223

Fr-223

100

Radium-223

Ra-223

0.1

Radium-224

Ra-224

0.1

Radium-225

Ra-225

0.1

Radium-226

Ra-226

0.1

Radium-227

Ra-227

1,000

Radium-228

Ra-228

0.1

Actinium-224

Ac-224

1

Hazardous Materials and Waste Management

132

Radionuclide

Abbreviation

Quantity (µCi)

Actinium-225

Ac-225

0.01

Actinium-226

Ac-226

0.1

Actinium-227

Ac-227

0.001

Actinium-228

Ac-228

1

Thorium-226

Th-226

10

Thorium-227

Th-227

0.01

Thorium-228

Th-228

0.001

Thorium-229

Th-229

0.001

Thorium-230

Th-230

0.001

Thorium-231

Th-231

100

Thorium-232

Th-232

100

Thorium-234

Th-234

10

Thorium-natural

100

Protactinium-227

Pa-227

10

Protactinium-228

Pa-228

1

Protactinium-230

Pa-230

0.1

Protactinium-231

Pa-231

0.001

Protactinium-232

Pa-232

1

Protactinium-233

Pa-233

100

Protactinium-234

Pa-234

100

Uranium-230

U-230

0.01

Uranium-231

U-231

100

Uranium-232

U-232

0.001

Uranium-233

U-233

0.001

Uranium-234

U-234

0.001

Uranium-235

U-235

0.001

Uranium-236

U-236

0.001

Uranium-237

U-237

100

Uranium-238

U-238

100

Uranium-239

U-239

1,000

Uranium-240

U-240

100

Uranium-natural

100

Neptunium-232

Np-232

100

Neptunium-233

Np-233

1,000

Neptunium-234

Np-234

100

Neptunium-235

Np-235

100

Neptunium-236 (1.15x105y)

Np-236

0.001

Neptunium-236 (22.5h)

Np-236

1

Neptunium-237

Np-237

0.001

Hazardous Materials and Waste Management

133

Radionuclide

Abbreviation

Quantity (µCi)

Neptunium-238

Np-238

10

Neptunium-239

Np-239

100

Neptunium-240

Np-240

1,000

Plutonium-234

Pu-234

10

Plutonium-235

Pu-235

1,000

Plutonium-236

Pu-236

0.001

Plutonium-237

Pu-237

100

Plutonium-238

Pu-238

0.001

Plutonium-239

Pu-239

0.001

Plutonium-240

Pu-240

0.001

Plutonium-241

Pu-241

0.01

Plutonium-242

Pu-242

0.001

Plutonium-243

Pu-243

1,000

Plutonium-244

Pu-244

0.001

Plutonium-245

Pu-245

100

Americium-237

Am-237

1,000

Americium-238

Am-238

100

Americium-239

Am-239

1,000

Americium-240

Am-240

100

Americium-241

Am-241

0.001

Americium-242m

Am-242m

0.001

Americium-242

Am-242

10

Americium-243

Am-243

0.001

Americium-244m

Am-244m

100

Americium-244

Am-244

10

Americium-245

Am-245

1,000

Americium-246m

Am-246

1,000

Americium-246

Am-246

1,000

Curium-238

Cm-238

100

Curium-240

Cm-240

0.1

Curium-241

Cm-241

1

Curium-242

Cm-242

0.01

Curium-243

Cm-243

0.001

Curium-244

Cm-244

0.001

Curium-245

Cm-245

0.001

Curium-246

Cm-246

0.001

Curium-247

Cm-247

0.001

Curium-248

Cm-248

0.001

Curium-249

Cm-249

1,000

Hazardous Materials and Waste Management

134

Radionuclide

Abbreviation

Quantity (µCi)

Berkelium-245

Bk-245

100

Berkelium-246

Bk-246

100

Berkelium-247

Bk-247

0.001

Berkelium-249

Bk-249

0.1

Berkelium-250

Bk-250

10

Californium-244

Cf-244

100

Californium-246

Cf-246

1

Californium-248

Cf-248

0.01

Californium-249

Cf-249

0.001

Californium-250

Cf-250

0.001

Californium-251

Cf-251

0.001

Californium-252

Cf-252

0.001

Californium-253

Cf-253

0.1

Californium-254

Cf-254

0.001

Any alpha emitting radionuclide not listed above or

mixtures or alpha emitters of unknown composition

0.001

Einsteinium-250

Es-250

100

Einsteinium-251

Es-251

100

Einsteinium-253

Es-253

0.1

Einsteinium-254m

Es-254m

1

Einsteinium-254

Es-254

0.01

Fermium-252

Fm-252

1

Fermium-253

Fm-253

1

Fermium-254

Fm-254

10

Fermium-255

Fm-255

1

Fermium-257

Fm-257

0.01

Me

This text is long and has been trimmed here. Open the source document for the complete record.

This is a copy of a public record, reproduced as it was published. It is not legal advice, and it may not be the version a court would rely on. Check the official source before you cite it.

A word about cookies

We need a few to keep you signed in and the library working. The rest help us see which pages people use and where they get stuck. They stay off unless you say yes.