§ 72.502 Requirements for nonpermissible light-duty diesel-powered equipment other than generators and compressors.

FederalRegulations

Ask Donna

How this section applies to your facts.

Title 30—Mineral Resources > CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR > SUBCHAPTER O—COAL MINE SAFETY AND HEALTH > PART 72—HEALTH STANDARDS FOR COAL MINES > Subpart D—Diesel Particulate Matter—Underground Areas of Underground Coal Mines

This text was captured on Sep 22, 2026. It is a snapshot, not a live feed, so check the official code before relying on it.

Text

(a) Each piece of nonpermissible light-duty diesel-powered equipment (as defined by § 75.1908(b) of this chapter), other than generators and compressors, introduced into an underground area of an underground coal mine after May 21, 2001 must emit no more than 5.0 grams per hour of diesel particulate matter.

(b) A piece of nonpermissible light-duty diesel-powered equipment must be deemed to be in compliance with the requirements of paragraph (a) of this section if it utilizes an engine which meets or exceeds the applicable particulate matter emission requirements of the Environmental Protection Administration listed in Table 72.502-1, as follows:

Table 72.502-1

EPA requirement

EPA category

PM limit

40 CFR 86.094-8(a)(1)(I)(A)(2)

light duty vehicle

0.1 g/mile.

40 CFR 86.094-9(a)(1)(I)(A)(2)

light duty truck

0.1 g/mile.

40 CFR 86.094-11(a)(1)(iv)(B)

heavy duty highway engine

0.1 g/bhp-hr.

40 CFR 89.112(a)

Tier 2 nonroad

Varies by power:

kW<(hp<11)

0.80 g/kW-hr (0.60 g/bhp-hr).

8≤kW<19 (11≤hp<25)

0.80 g/kW-hr (0.60 g/bhp-hr).

19≤kW<37 (25≤hp<50)

0.60 g/kW-hr (0.45 g/bhp-hr).

37≤kW<75 (50≤hp<100)

0.40 g/kW-hr (0.30 g/bhp-hr).

75≤kW<130 (100≤hp<175)

0.30 g/kW-hr (0.22 g/bhp-hr).

130≤kW<225 (175≤hp<300)

0.20 g/kW-hr (0.15 g/bhp-hr).

225≤kW<450 (300≤hp<600)

0.20 g/kW-hr (0.15 g/bhp-hr).

450≤kW<560 (600≤hp<750)”

0.20 g/kW-hr (0.15 g/bhp-hr)

kW≥560 (hp≥750)

0.20 g/kW-hr (0.15 g/bhp-hr)

Notes: “g” means grams; “kW” means kilowatt; “hp” means horsepower; “g/kW-hr” means grams/kilowatt-hour; “g/bhp-hr” means grams/brake horsepower-hour.

(c) The requirements of this section do not apply to any diesel-powered ambulance or fire fighting equipment that is being used in accordance with the mine fire fighting and evacuation plan under § 75.1502.

[66 FR 5704, Jan. 19, 2001, as amended at 66 FR 15033, Mar. 15, 2001; 66 FR 27866, May 21, 2001; 70 FR 36347, June 23, 2005]

This is a copy of a public record, reproduced as it was published. It is not legal advice, and it may not be the version a court would rely on. Check the official source before you cite it.

A word about cookies

We need a few to keep you signed in and the library working. The rest help us see which pages people use and where they get stuck. They stay off unless you say yes.

§ 72.502 Requirements for nonpermissible light-duty diesel-powered equipment other than generators and compressors. · 30 CFR § 72.502 | Frix