§ 27.307 Proof of structure.
FederalRegulations
Ask Donna
How this section applies to your facts.
Title 14—Aeronautics and Space > CHAPTER I—FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION > SUBCHAPTER C—AIRCRAFT > PART 27—AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT > Subpart C—Strength Requirements > General
Text
(a) Compliance with the strength and deformation requirements of this subpart must be shown for each critical loading condition accounting for the environment to which the structure will be exposed in operation. Structural analysis (static or fatigue) may be used only if the structure conforms to those structures for which experience has shown this method to be reliable. In other cases, substantiating load tests must be made.
(b) Proof of compliance with the strength requirements of this subpart must include—
(1) Dynamic and endurance tests of rotors, rotor drives, and rotor controls;
(2) Limit load tests of the control system, including control surfaces;
(3) Operation tests of the control system;
(4) Flight stress measurement tests;
(5) Landing gear drop tests; and
(6) Any additional test required for new or unusual design features.
(Secs. 604, 605, 72 Stat. 778, 49 U.S.C. 1424, 1425)
[Doc. No. 5074, 29 FR 15695, Nov. 24, 1964, as amended by Amdt. 27-3, 33 FR 14105, Sept. 18, 1968; Amdt. 27-26, 55 FR 7999, Mar. 6, 1990]