Section 935.40 Camp Sites
IllinoisRegulations
Ask Donna
How this section applies to your facts.
Illinois Administrative Code › Title 77 PUBLIC HEALTH › CHAPTER I: DEPARTMENT OF PUBLIC HEALTH › Part 935 MIGRANT LABOR CAMP CODE › Section 935.40 Camp Sites
Text
Section 935
Section 935.40 Camp Sites
a) Camp Location. Camp sites shall be well drained, free of
weeds, insects and obnoxious odors and also free from depressions in which
water may stand. Housing units shall not be located within 200 feet of swamps,
sinks holes, or other surface collections of water unless mosquito control
measures are undertaken. The site location shall not create hazardous traffic
conditions. Each site shall be of a size to permit the spacing of buildings and
vehicles to minimize fire hazards as required by Section 935.100(a). All
housing units and areas where food is prepared or served shall be located at
least 500 feet from livestock areas. (B)
b) Maintenance of Camps. The camp shall be kept free of debris,
tall vegetation, and abandoned equipment. (C)
c) Housing Units.
1) All structures intended for occupancy shall be structurally
sound, maintained to support the wind and snow loads and shall be waterproof.
(A)
2) All floors shall be of an impervious non-absorbent material
that can be cleaned. The top of wooden floors shall be at least 12 inches
above the ground level, except for structures occupied prior to April 3, 1980.
(C)
3) All walls and ceilings shall have a smooth finish that can be
cleaned with soap and water. Any area subject to splash shall be made of an
impervious material. Exposed studs and rafters are acceptable only for housing
units occupied prior to January 1, 1990. All habitable rooms shall have a
minimum 7 foot high ceiling. (C)
4) Each room used for sleeping purposes shall contain at least 50
square feet of floor space per occupant except that camps occupied prior to
April 3, 1980 shall have at least 40 square feet per person if bunk beds are
used. A minimum of 100 square feet per person shall be provided in combined
cooking and sleeping rooms except that a minimum of 60 square feet per person
shall be provided for those camps occupied prior to April 3, 1980
l contain at least 50
square feet of floor space per occupant except that camps occupied prior to
April 3, 1980 shall have at least 40 square feet per person if bunk beds are
used. A minimum of 100 square feet per person shall be provided in combined
cooking and sleeping rooms except that a minimum of 60 square feet per person
shall be provided for those camps occupied prior to April 3, 1980. (B)
5) All rooms except toilet rooms and kitchens shall be provided
with windows, the total area of which shall be not less than one-tenth of the
floor area. At least one-half of each window shall be so constructed that it
can be opened for purposes of ventilation. Rooms without openable windows must
have mechanical ventilation capable of producing a change of air every 30 minutes.
(C)
6) All exterior openings shall be screened with 16-mesh
material. All screen doors shall be equipped with self-closing devices. (C)
7) Beds, cots, or bunks, and suitable storage facilities such as
wall lockers, closets or dressers for clothing and personal articles shall be
provided in every room used for sleeping purposes. Six inches of clearance
shall be provided between the floor and the bottom of all springs or
mattresses. The minimum clear space between the lower and upper bunk shall be
at least 27 inches. Triple-deck bunks are prohibited. For structures
initially occupied after April 3, 1980, there shall be 36 inch separation
between single beds and 48 inch separation between sets of bunk beds. (C)
8) Separate quarters shall be provided for each sex except in the
case of family living quarters. A partitioned sleeping area for the husband
and wife shall be enclosed from floor to a height of at least six feet, with a
gap not to exceed 4 inches at the floor being allowable. The entrance to the
sleeping quarters shall be equipped with a curtain or door. (C)
9) The housing units shall be kept free of animal or insect
vectors or pests. (B)
d) Bedding
ily living quarters. A partitioned sleeping area for the husband
and wife shall be enclosed from floor to a height of at least six feet, with a
gap not to exceed 4 inches at the floor being allowable. The entrance to the
sleeping quarters shall be equipped with a curtain or door. (C)
9) The housing units shall be kept free of animal or insect
vectors or pests. (B)
d) Bedding.
1) The licensee shall be responsible for maintaining all bedding
that is provided by the licensee in a clean and sanitary condition. (C)
2) Sheets and pillow cases, when provided, shall be laundered at
least once each week and before use by each new worker. (C)
3) Blankets, when provided, shall be washed as often as necessary
to maintain cleanliness, and at least annually. (C)
4) Mattresses shall be provided and shall be covered with
removable covers which shall be washed before use by each new worker. If
mattresses and pillows cannot be cleaned, they shall be discarded. (C)
5) If mattress bags are provided, they shall be washed at least
once each operating season and before use by each new worker. The mattress
filling shall be changed at the time the bags are washed. (C)
This is a copy of a public record, reproduced as it was published. It is not legal advice, and it may not be the version a court would rely on. Check the official source before you cite it.