Section 105

Section 105.10  Fireworks

Plant Fencing

a)         Specifications and Maintenance. The fence required by section

13 (a) of the fireworks act referred to above, Ill. Rev. Stat., ch. 127½, par.

113 (a), shall substantially meet the specifications set forth in Rules 1.01

through 1.06 (41 Ill. Adm. Code Section 100.82 (a) through (g)) and shall be

properly maintained at all times.

b)         Height. The fence shall be not less than seventy-two (72)

inches high at all points.

c)         Support. The fence shall be firmly attached to or rigidly

supported by steel or wood posts set on not more than ten (10) foot centers

anchored in firm ground not less than twenty-four (24) inches deep.

d)         Top Arm. The fence shall have an arm securely fastened on top

and extending outward at an angle of not less than thirty-five (35) degrees nor

more than one hundred eighty (180) degrees, except that the arm on a gate may

be vertical. The arm atop the fence shall be not less than twelve (12) inches

wide and extend the length of the fence. The arm atop the fence shall carry

three (3) strands of barbed wire spaced not less than five (5) inches apart.

The barbed wire shall consist of a double cable of no. 14 gauge, or heavier,

galvanized steel wire with two or more point barbs tightly and doubly twisted

around and through the cable wires and set not more than six (6) inches apart.

e)         Fence Structure. The vertical part of said fence shall consist

of line and stay wires. The bottom line wire shall be flush with the ground.

The stay wires shall be welded to or interwoven with the line wires and spaced

on not more than two (2) inch centers forming a rectangle or diamond shape

mesh. The line wires and stay wires may be interwoven as to form chain links.

All line wires and stay wires shall be of no. 11 gauge, or heavier, steel

galvanized wire.

f)         Gates

s. The bottom line wire shall be flush with the ground.

The stay wires shall be welded to or interwoven with the line wires and spaced

on not more than two (2) inch centers forming a rectangle or diamond shape

mesh. The line wires and stay wires may be interwoven as to form chain links.

All line wires and stay wires shall be of no. 11 gauge, or heavier, steel

galvanized wire.

f)         Gates. All openings in the fence shall be equipped with metal

gates which shall be kept securely locked at all times, except when in actual

use, provided that the main gate of the plant may be left open during the

regular hours of plant operation while in plain view of and under observation

by authorized employees or guards.

g)         Material. Whenever a particular material is specified in these

rules and regulations, material of at least equivalent strength and quality may

be substituted.

This is a copy of a public record, reproduced as it was published. It is not legal advice, and it may not be the version a court would rely on. Check the official source before you cite it.

A word about cookies

We need a few to keep you signed in and the library working. The rest help us see which pages people use and where they get stuck. They stay off unless you say yes.

Section 105.10 Fireworks Plant Fencing · 41 Ill. Adm. Code 105.10 | Frix