§ 431.86 Uniform test method for the measurement of energy efficiency of commercial packaged boilers.
FederalRegulations
Ask Donna
How this section applies to your facts.
Title 10 CFR: Energy › Chapter II: DEPARTMENT OF ENERGY › Part 431: ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT › Subpart E: Commercial Packaged Boilers › § 431.86: § 431.86 Uniform test method for the measurement of energy efficiency of commercial packaged boilers.
Text
(a)
Scope.
This section provides test procedures, pursuant to the Energy Policy and Conservation Act (EPCA), as amended, which must be followed for measuring the combustion efficiency and/or thermal efficiency of a gas- or oil-fired commercial packaged boiler.
(b)
Testing and Calculations.
Determine the thermal efficiency or combustion efficiency of commercial packaged boilers by conducting the appropriate test procedure(s) indicated in Table 1 of this section.
Table 1—Test Requirements for Commercial Packaged Boiler Equipment Classes
Equipment category
Subcategory
Certified rated input
Btu/h
Standards efficiency metric
(§ 431.87)
Test procedure
(corresponding to
standards efficiency
metric required
by § 431.87)
Hot Water
Gas-fired
≥300,000 and ≤2,500,000
Thermal Efficiency
Appendix A, Section 2.
Hot Water
Gas-fired
>2,500,000
Combustion Efficiency
Appendix A, Section 3.
Hot Water
Oil-fired
≥300,000 and ≤2,500,000
Thermal Efficiency
Appendix A, Section 2.
Hot Water
Oil-fired
>2,500,000
Combustion Efficiency
Appendix A, Section 3.
Steam
Gas-fired (all*)
≥300,000 and ≤2,500,000
Thermal Efficiency
Appendix A, Section 2.
Steam
Gas-fired (all*)
>2,500,000 and ≤5,000,000
Thermal Efficiency
Appendix A, Section 2.
>5,000,000
Thermal Efficiency
Appendix A, Section 2.
OR
Appendix A, Section 3 with Section 2.4.3.2.
Steam
Oil-fired
≥300,000 and ≤2,500,000
Thermal Efficiency
Appendix A, Section 2.
Steam
Oil-fired
>2,500,000 and ≤5,000,000
Thermal Efficiency
Appendix A, Section 2.
>5,000,000
Thermal Efficiency
Appendix A, Section 2.
OR
Appendix A, Section 3. with Section 2.4.3.2.
* Equipment classes for commercial packaged boilers as of July 22, 2009 (74 FR 36355) distinguish between gas-fired natural draft and all other gas-fired (except natural draft).
(c)
Field Tests.
The field test provisions of appendix A may be used only to test a unit of commercial packaged boiler with rated input greater than 5,000,000 Btu/h.
[81 FR 89305, Dec. 9, 2016]