§ 27.207 What are the requirements for fuel shut-offs on towing vessels?

FederalRegulations

Ask Donna

How this section applies to your facts.

Title 46—Shipping > CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY > SUBCHAPTER C—UNINSPECTED VESSELS > PART 27—TOWING VESSELS > Subpart B—Fire-Protection Measures for Towing Vessels

This text was captured on Sep 22, 2026. It is a snapshot, not a live feed, so check the official code before relying on it.

Text

To stop the flow of fuel in the event of a break in the fuel line, you must have a positive, remote fuel-shut-off valve fitted on any fuel line that supplies fuel directly to an engine or generator. The valve must be near the source of supply (for instance, at the day tank, storage tank, or fuel-distribution manifold). Furthermore, it must be operable from a safe place outside the space where the valve is installed. Each remote valve control should be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the way to operate it.

This is a copy of a public record, reproduced as it was published. It is not legal advice, and it may not be the version a court would rely on. Check the official source before you cite it.