Section 611.102 Incorporations by Reference
IllinoisRegulations
Ask Donna
How this section applies to your facts.
Illinois Administrative Code › Title 35 › › Part 6110 › Section 611.102 Incorporations by Reference
Text
Section 611
TITLE 35: ENVIRONMENTAL PROTECTION
SUBTITLE F: PUBLIC WATER SUPPLIES
CHAPTER I: POLLUTION CONTROL BOARD
PART 611 PRIMARY DRINKING WATER STANDARDS
SECTION 611.102 INCORPORATIONS BY REFERENCE
Section 611.102
Incorporations by Reference
a) Analytical
Methods. The Board incorporates by reference the following analytical
methods. The rules refer to the methods by the defined short-form names given
them in this Section.
"AMI Turbiwell (09)"
means "Continuous Measurement of Turbidity Using a SWAN AMI Turbiwell
Turbidimeter" (August 10, 2009). Available from SWAN Analytische
Instrumente AG, Studbachstrasse 13, CH-8340, Hinwil, Switzerland. Referenced
in Section 611.531. Available from the publisher; NEMI; and USEPA, OGWDW
(under "Surface Water Treatment Rule (PDF)").
ASTM Methods. Available from ASTM
International, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959 (https://www.astm.org/products-services/standards-and-publications.html).
"ASTM
D511-93 A
" means "Standard Test Methods for Calcium and Magnesium
in Water", "Test Method A − Complexometric Titration",
approved 1993, referenced in Section 611.611.
"ASTM D511-03 A" means "Standard
Test Methods for Calcium and Magnesium in Water", "Test Method A
− Complexometric Titration", approved 2003, referenced in Section
611.611.
"ASTM D511-09 A" means "Standard
Test Methods for Calcium and Magnesium in Water", "Test Method A
− Complexometric Titration", approved 2009, referenced in Section
611.611.
"ASTM D511-14 A" means "Standard
Test Methods for Calcium and Magnesium in Water", "Test Method A
− Complexometric Titration", approved 2014, referenced in Section
611.611.
"ASTM D511-93 B" means "Standard
Test Methods for Calcium and Magnesium in Water", "Test Method B
− Atomic Absorption Spectrophotometric", approved 1993, referenced
in Section 611.611
2009, referenced in Section
611.611.
"ASTM D511-14 A" means "Standard
Test Methods for Calcium and Magnesium in Water", "Test Method A
− Complexometric Titration", approved 2014, referenced in Section
611.611.
"ASTM D511-93 B" means "Standard
Test Methods for Calcium and Magnesium in Water", "Test Method B
− Atomic Absorption Spectrophotometric", approved 1993, referenced
in Section 611.611.
"ASTM D511-03 B" means "Standard
Test Methods for Calcium and Magnesium in Water", "Test Method B
− Atomic Absorption Spectrophotometric", approved 2003, referenced
in Section 611.611.
"ASTM D511-09 B" means "Standard
Test Methods for Calcium and Magnesium in Water", "Test Method B
− Atomic Absorption Spectrophotometric", approved 2009, referenced
in Section 611.611.
"ASTM D511-14 B" means "Standard
Test Methods for Calcium and Magnesium in Water", "Test Method B
− Atomic Absorption Spectrophotometric", approved 2014, referenced
in Section 611.611.
"ASTM D515-88 A" means "Standard
Test Methods for Phosphorus in Water", "Test Method A − Colorimetric
Ascorbic Acid Reduction", approved August 19, 1988, referenced in Section
611.611.
"ASTM D859-94" means "Standard
Test Method for Silica in Water", approved 1994, referenced in Section
611.611.
"ASTM D859-00" means "Standard
Test Method for Silica in Water", approved 2000, referenced in Section
611.611.
"ASTM D859-05" means "Standard
Test Method for Silica in Water", approved 2005, referenced in Section
611.611.
"ASTM D859-10" means "Standard
Test Method for Silica in Water", approved 2010, referenced in Section
611.611.
"ASTM D859-16" means "Standard
Test Method for Silica in Water", approved 2016, referenced in Section
611.611.
"ASTM D1067-92 B" means "Standard
Test Methods for Acidity or Alkalinity in Water", "Test Method B
− Electrometric or Color-Change Titration", approved May 15, 1992,
referenced in Section 611.611
andard
Test Method for Silica in Water", approved 2010, referenced in Section
611.611.
"ASTM D859-16" means "Standard
Test Method for Silica in Water", approved 2016, referenced in Section
611.611.
"ASTM D1067-92 B" means "Standard
Test Methods for Acidity or Alkalinity in Water", "Test Method B
− Electrometric or Color-Change Titration", approved May 15, 1992,
referenced in Section 611.611.
"ASTM D1067-02 B" means "Standard
Test Methods for Acidity or Alkalinity in Water", "Test Method B
− Electrometric or Color-Change Titration", approved in 2002,
referenced in Section 611.611.
"ASTM D1067-06 B" means "Standard
Test Methods for Acidity or Alkalinity in Water", "Test Method B
− Electrometric or Color-Change Titration", approved in 2006,
referenced in Section 611.611.
"ASTM D1067-11 B" means "Standard
Test Methods for Acidity or Alkalinity in Water", "Test Method B
− Electrometric or Color-Change Titration", approved in 2011,
referenced in Section 611.611.
"ASTM D1067-16 B" means "Standard
Test Methods for Acidity or Alkalinity in Water", "Test Method B
− Electrometric or Color-Change Titration", approved in 2006,
referenced in Section 611.611.
"ASTM D1125-95 (1999) A"
means "Standard Test Methods for Electrical Conductivity and Resistivity
of Water", "Test Method A − Field and Routine Laboratory
Measurement of Static (Non-Flowing) Samples", approved 1995, reapproved
1999, referenced in Section 611.611.
"ASTM D1179-93 B" means "Standard
Test Methods for Fluoride in Water", "Test Method B − Ion
Selective Electrode", approved 1993, referenced in Section 611.611.
"ASTM D1179-99 B" means "Standard
Test Methods for Fluoride in Water", "Test Method B − Ion
Selective Electrode", approved 1999, referenced in Section 611.611.
"ASTM D1179-04 B" means "Standard
Test Methods for Fluoride in Water", "Test Method B − Ion
Selective Electrode", approved 2004, referenced in Section 611.611
B − Ion
Selective Electrode", approved 1993, referenced in Section 611.611.
"ASTM D1179-99 B" means "Standard
Test Methods for Fluoride in Water", "Test Method B − Ion
Selective Electrode", approved 1999, referenced in Section 611.611.
"ASTM D1179-04 B" means "Standard
Test Methods for Fluoride in Water", "Test Method B − Ion
Selective Electrode", approved 2004, referenced in Section 611.611.
"ASTM D1179-10 B" means "Standard
Test Methods for Fluoride in Water", "Test Method B − Ion
Selective Electrode", approved 2010, referenced in Section 611.611.
"ASTM D1179-16 B" means "Standard
Test Methods for Fluoride in Water", "Test Method B − Ion
Selective Electrode", approved 2010, referenced in Section 611.611.
"ASTM D1253-86" means "Standard
Test Method for Residual Chlorine in Water", reapproved 1992, referenced
in Section 611.381.
"ASTM D1253-96" means "Standard
Test Method for Residual Chlorine in Water", approved 1996, referenced in
Section 611.381.
"ASTM D1253-03" means "Standard
Test Method for Residual Chlorine in Water", approved 2003, referenced in
Sections 611.381 and 611.531.
"ASTM D1253-08" means "Standard
Test Method for Residual Chlorine in Water", approved 2008, referenced in
Sections 611.381 and 611.531.
"ASTM D1253-14" means "Standard
Test Method for Residual Chlorine in Water", approved 2014, referenced in
Sections 611.381 and 611.531.
"ASTM D1293-95" means "Standard
Test Methods for pH of Water", approved 1995, referenced in Section
611.611.
"ASTM D1293-99" means "Standard
Test Methods for pH of Water", approved 1999, referenced in Section
611.611.
"ASTM D1293-12" means "Standard
Test Methods for pH of Water", approved 2012, referenced in Section
611.611.
"ASTM D1293-18" means "Standard
Test Methods for pH of Water", approved 2018, referenced in Section
611.611.
"ASTM D1688-95 A" means "Standard
Test Methods for Copper in Water", "Test Method A − Atomic
Absorption, Direct", approved 1995, referenced in Section 611.611
Section
611.611.
"ASTM D1293-12" means "Standard
Test Methods for pH of Water", approved 2012, referenced in Section
611.611.
"ASTM D1293-18" means "Standard
Test Methods for pH of Water", approved 2018, referenced in Section
611.611.
"ASTM D1688-95 A" means "Standard
Test Methods for Copper in Water", "Test Method A − Atomic
Absorption, Direct", approved 1995, referenced in Section 611.611.
"ASTM D1688-02 A" means "Standard
Test Methods for Copper in Water", "Test Method A − Atomic
Absorption, Direct", approved 2002, referenced in Section 611.611.
"ASTM D1688-07 A" means "Standard
Test Methods for Copper in Water", "Test Method A − Atomic
Absorption, Direct", approved 2007, referenced in Section 611.611.
"ASTM D1688-12 A" means "Standard
Test Methods for Copper in Water", "Test Method A − Atomic
Absorption, Direct", approved 2012, referenced in Section 611.611.
"ASTM D1688-17 A" means "Standard
Test Methods for Copper in Water", "Test Method A − Atomic
Absorption, Direct", approved 2017, referenced in Section 611.611.
"ASTM D1688-95 C" means "Standard
Test Methods for Copper in Water", "Test Method C − Atomic
Absorption, Graphite Furnace", approved 1995, referenced in Section
611.611.
"ASTM D1688-02 C" means "Standard
Test Methods for Copper in Water", "Test Method C − Atomic
Absorption, Graphite Furnace", approved 2002, referenced in Section
611.611.
"ASTM D1688-07 C" means "Standard
Test Methods for Copper in Water", "Test Method C − Atomic Absorption,
Graphite Furnace", approved 2007, referenced in Section 611.611.
"ASTM D1688-12 C" means "Standard
Test Methods for Copper in Water", "Test Method C − Atomic
Absorption, Graphite Furnace", approved 2012, referenced in Section
611.611.
"ASTM D1688-17 C" means "Standard
Test Methods for Copper in Water", "Test Method C − Atomic
Absorption, Graphite Furnace", approved 2017, referenced in Section
611.611
Furnace", approved 2007, referenced in Section 611.611.
"ASTM D1688-12 C" means "Standard
Test Methods for Copper in Water", "Test Method C − Atomic
Absorption, Graphite Furnace", approved 2012, referenced in Section
611.611.
"ASTM D1688-17 C" means "Standard
Test Methods for Copper in Water", "Test Method C − Atomic
Absorption, Graphite Furnace", approved 2017, referenced in Section
611.611.
"ASTM D2036-98 A" means "Standard
Test Methods for Cyanide in Water", "Test Method A − Total
Cyanides after Distillation", approved 1998, referenced in Section
611.611.
"ASTM D2036-06 A" means "Standard
Test Methods for Cyanide in Water", "Test Method A − Total
Cyanides after Distillation", approved 2006, referenced in Section
611.611.
"ASTM D2036-98 B" means "Standard
Test Methods for Cyanide in Water", "Test Method B − Cyanides
Amenable to Chlorination by Difference", approved 1998, referenced in
Section 611.611.
"ASTM D2036-06 B" means "Standard
Test Methods for Cyanide in Water", "Test Method B − Cyanides
Amenable to Chlorination by Difference", approved 2006, referenced in
Section 611.611.
"ASTM D2459-72" means "Standard
Test Method for Gamma Spectrometry in Water", approved July 28, 1972,
discontinued 1988, referenced in Section 611.720.
"ASTM D2460-97" means "Standard
Test Method for Radionuclides of Radium in Water", approved 1997,
referenced in Section 611.720.
"ASTM D2460-07" means "Standard
Test Method for Radionuclides of Radium in Water", approved 2007,
referenced in Section 611.720.
"ASTM D2907-97" means "Standard
Test Methods for Microquantities of Uranium in Water by Fluorometry",
approved 1997, referenced in Section 611.720.
"ASTM D2972-97 B" means "Standard
Test Methods for Arsenic in Water", "Test Method B − Atomic
Absorption, Hydride Generation", approved 1997, referenced in Section
611.611.
"ASTM D2972-03 B" means "Standard
Test Methods for Arsenic in Water", "Test Method B − Atomic
Absorption, Hydride Generation", approved 2003, referenced in Section 611.611
y",
approved 1997, referenced in Section 611.720.
"ASTM D2972-97 B" means "Standard
Test Methods for Arsenic in Water", "Test Method B − Atomic
Absorption, Hydride Generation", approved 1997, referenced in Section
611.611.
"ASTM D2972-03 B" means "Standard
Test Methods for Arsenic in Water", "Test Method B − Atomic
Absorption, Hydride Generation", approved 2003, referenced in Section 611.611.
"ASTM D2972-15 B" means "Standard
Test Methods for Arsenic in Water", "Test Method B − Atomic
Absorption, Hydride Generation", approved 2015, referenced in Section
611.611.
"ASTM D2972-97 C" means "Standard
Test Methods for Arsenic in Water", "Test Method C − Atomic
Absorption, Graphite Furnace", approved 1997, referenced in Section
611.611.
"ASTM D2972-03 C" means "Standard
Test Methods for Arsenic in Water", "Test Method C − Atomic
Absorption, Graphite Furnace", approved 2003, referenced in Section
611.611.
"ASTM D2972-15 C" means "Standard
Test Methods for Arsenic in Water", "Test Method C − Atomic
Absorption, Graphite Furnace", approved 2015, referenced in Section
611.611.
"ASTM D3223-97" means "Standard
Test Method for Total Mercury in Water", approved 1997, referenced in
Section 611.611.
"ASTM D3223-02" means "Standard
Test Method for Total Mercury in Water", approved 2002, referenced in
Section 611.611.
"ASTM D3223-12" means "Standard
Test Method for Total Mercury in Water", approved 2012, referenced in
Section 611.611.
"ASTM D3223-17" means "Standard
Test Method for Total Mercury in Water", approved 2017, referenced in
Section 611.611.
"ASTM D3454-97" means "Standard
Test Method for Radium-226 in Water", approved 1997, referenced in Section
611.720.
"ASTM D3454-05" means "Standard
Test Method for Radium-226 in Water", approved 2005, referenced in Section
611.720.
"ASTM D3454-18" means "Standard
Test Method for Radium-226 in Water", approved 2018, referenced in Section
611.720
approved 2017, referenced in
Section 611.611.
"ASTM D3454-97" means "Standard
Test Method for Radium-226 in Water", approved 1997, referenced in Section
611.720.
"ASTM D3454-05" means "Standard
Test Method for Radium-226 in Water", approved 2005, referenced in Section
611.720.
"ASTM D3454-18" means "Standard
Test Method for Radium-226 in Water", approved 2018, referenced in Section
611.720.
"ASTM D3454-21" means "Standard
Test Method for Radium-226 in Water", approved 2021, referenced in Section
611.720.
"ASTM D3559-96 D" means "Standard
Test Methods for Lead in Water", "Test Method D − Atomic
Absorption, Graphite Furnace", approved August 6, 1990, referenced in
Section 611.611.
"ASTM D3559-03 D" means "Standard
Test Methods for Lead in Water", "Test Method D − Atomic
Absorption, Graphite Furnace", approved 2003, referenced in Section
611.611.
"ASTM D3559-08 D" means "Standard
Test Methods for Lead in Water", "Test Method D − Atomic
Absorption, Graphite Furnace", approved 2008, referenced in Section
611.611.
"ASTM D3559-15 D" means "Standard
Test Methods for Lead in Water", "Test Method D − Atomic
Absorption, Graphite Furnace", approved 2015, referenced in Section
611.611.
"ASTM D3645-97 B" means "Standard
Test Methods for Beryllium in Water", "Method B − Atomic
Absorption, Graphite Furnace", approved 1997, referenced in Section
611.611.
"ASTM D3645-03 B" means "Standard
Test Methods for Beryllium in Water", "Method B − Atomic
Absorption, Graphite Furnace", approved 2003, referenced in Section
611.611.
"ASTM D3645-08 B" means "Standard
Test Methods for Beryllium in Water", "Method B − Atomic
Absorption, Graphite Furnace", approved 2008, referenced in Section
611.611.
"ASTM D3645-15 B" means "Standard
Test Methods for Beryllium in Water", "Method B − Atomic
Absorption, Graphite Furnace", approved 2015, referenced in Section
611.611.
"ASTM D3649-91" means "Standard
Test Method for High-Resolution Gamma-Ray Spectrometry of Water", approved
1991, referenced in Section 611.720
tomic
Absorption, Graphite Furnace", approved 2008, referenced in Section
611.611.
"ASTM D3645-15 B" means "Standard
Test Methods for Beryllium in Water", "Method B − Atomic
Absorption, Graphite Furnace", approved 2015, referenced in Section
611.611.
"ASTM D3649-91" means "Standard
Test Method for High-Resolution Gamma-Ray Spectrometry of Water", approved
1991, referenced in Section 611.720.
"ASTM D3649-98a" means "Standard
Test Method for High-Resolution Gamma-Ray Spectrometry of Water", approved
1998, referenced in Section 611.720.
"ASTM D3649-06" means "Standard
Test Method for High-Resolution Gamma-Ray Spectrometry of Water", approved
2006, referenced in Section 611.720.
"ASTM D3697-92" means "Standard
Test Method for Antimony in Water", approved 1992, referenced in Section
611.611.
"ASTM D3697-02" means "Standard
Test Method for Antimony in Water", approved 2002, referenced in Section
611.611.
"ASTM D3697-07" means "Standard
Test Method for Antimony in Water", approved 2007, referenced in Section
611.611.
"ASTM D3697-12" means "Standard
Test Method for Antimony in Water", approved 2012, referenced in Section
611.611.
"ASTM D3697-17" means "Standard
Test Method for Antimony in Water", approved 2017, referenced in Section
611.611.
"ASTM D3859-98 A" means "Standard
Test Methods for Selenium in Water", "Method A − Atomic
Absorption, Hydride Method", approved 1998, referenced in Section 611.611.
"ASTM D3859-03 A" means "Standard
Test Methods for Selenium in Water", "Method A − Atomic
Absorption, Hydride Method", approved 2003, referenced in Section 611.611.
"ASTM D3859-08 A" means "Standard
Test Methods for Selenium in Water", "Method A − Atomic
Absorption, Hydride Method", approved 2008, referenced in Section 611.611.
"ASTM D3859-15 A" means "Standard
Test Methods for Selenium in Water", "Method A − Atomic
Absorption, Hydride Method", approved 2015, referenced in Section 611.611
ion, Hydride Method", approved 2003, referenced in Section 611.611.
"ASTM D3859-08 A" means "Standard
Test Methods for Selenium in Water", "Method A − Atomic
Absorption, Hydride Method", approved 2008, referenced in Section 611.611.
"ASTM D3859-15 A" means "Standard
Test Methods for Selenium in Water", "Method A − Atomic
Absorption, Hydride Method", approved 2015, referenced in Section 611.611.
"ASTM D3859-98 B" means "Standard
Test Methods for Selenium in Water", "Method B − Atomic
Absorption, Graphite Furnace", approved 1998, referenced in Section
611.611.
"ASTM D3859-03 B" means "Standard
Test Methods for Selenium in Water", "Method B − Atomic
Absorption, Graphite Furnace", approved 2003, referenced in Section
611.611.
"ASTM D3859-08 B" means "Standard
Test Methods for Selenium in Water", "Method B − Atomic
Absorption, Graphite Furnace", approved 2008, referenced in Section
611.611.
"ASTM D3859-15 B" means "Standard
Test Methods for Selenium in Water", "Method B − Atomic
Absorption, Graphite Furnace", approved 2015, referenced in Section
611.611.
"ASTM D3867-90 A" means "Standard
Test Methods for Nitrite-Nitrate in Water", "Test Method A − Automated
Cadmium Reduction", approved 1990, referenced in Section 611.611.
"ASTM D3867-90 B" means "Standard
Test Methods for Nitrite-Nitrate in Water", "Test Method B − Manual
Cadmium Reduction", approved January 10, 1990, referenced in Section
611.611.
"ASTM D3972-97" means "Standard
Test Method for Isotopic Uranium in Water by Radiochemistry", approved
1997, referenced in Section 611.720.
"ASTM D3972-02" means "Standard
Test Method for Isotopic Uranium in Water by Radiochemistry", approved
2002, referenced in Section 611.720.
"ASTM D3972-09" means "Standard
Test Method for Isotopic Uranium in Water by Radiochemistry", approved
2009, referenced in Section 611.720.
"ASTM D4107-91" means "Standard
Test Method for Tritium in Drinking Water", approved 1991, referenced in
Section 611.720
D3972-02" means "Standard
Test Method for Isotopic Uranium in Water by Radiochemistry", approved
2002, referenced in Section 611.720.
"ASTM D3972-09" means "Standard
Test Method for Isotopic Uranium in Water by Radiochemistry", approved
2009, referenced in Section 611.720.
"ASTM D4107-91" means "Standard
Test Method for Tritium in Drinking Water", approved 1991, referenced in
Section 611.720.
"ASTM D4107-98" means "Standard
Test Method for Tritium in Drinking Water", approved 1998, referenced in
Section 611.720.
"ASTM D4107-08" means "Standard
Test Method for Tritium in Drinking Water", approved 2008, referenced in
Section 611.720.
"ASTM
D4107-20" means "Standard Test Method for Tritium in Drinking Water
",
approved 2020, referenced in Section 611.720.
"ASTM D4327-97" means "Standard
Test Method for Anions in Water by Ion Chromatography", approved 1997,
referenced in Section 611.611.
"ASTM D4327-03" means "Standard
Test Method for Anions in Water by Ion Chromatography", approved 2003,
referenced in Section 611.611.
"ASTM D4327-11" means "Standard
Test Method for Anions in Water by Ion Chromatography", approved 2011,
referenced in Section 611.611.
"ASTM D4327-17" means "Standard
Test Method for Anions in Water by Ion Chromatography", approved 2017,
referenced in Section 611.611.
"ASTM D4785-93" means "Standard
Test Method for Low-Level Iodine-131 in Water", approved 1993, referenced
in Section 611.720.
"ASTM D4785-00a" means "Standard
Test Method for Low-Level Iodine-131 in Water", approved 2000, referenced
in Section 611.720.
"ASTM D4785-08" means "Standard
Test Method for Low-Level Iodine-131 in Water", approved 2008, referenced
in Section 611.720.
"ASTM D4785-20" means "Standard
Test Method for Low-Level Iodine-131 in Water", approved 2020, referenced
in Section 611.720.
"ASTM D5174-97" means "Standard
Test Method for Trace Uranium in Water by Pulsed-Laser Phosphorimetry",
approved 1997, referenced in Section 611.720
D4785-08" means "Standard
Test Method for Low-Level Iodine-131 in Water", approved 2008, referenced
in Section 611.720.
"ASTM D4785-20" means "Standard
Test Method for Low-Level Iodine-131 in Water", approved 2020, referenced
in Section 611.720.
"ASTM D5174-97" means "Standard
Test Method for Trace Uranium in Water by Pulsed-Laser Phosphorimetry",
approved 1997, referenced in Section 611.720.
"ASTM D5174-02" means "Standard
Test Method for Trace Uranium in Water by Pulsed-Laser Phosphorimetry",
approved 2002, referenced in Section 611.720.
"ASTM D5174-07" means "Standard
Test Method for Trace Uranium in Water by Pulsed-Laser Phosphorimetry", approved
2007, referenced in Section 611.720.
"ASTM D5317-93" means "Standard
Test Method for Determination of Chlorinated Organic Acid Compounds in Water by
Gas Chromatography with an Electron Capture Detector", approved 1993,
referenced in Section 611.645.
"ASTM D5317-98(2003)"
means "Standard Test Method for Determination of Chlorinated Organic Acid
Compounds in Water by Gas Chromatography with an Electron Capture Detector",
approved 1998 (reapproved 2003), referenced in Section 611.645.
"ASTM
D5317-20" means "Standard Test Method for Determination of
Chlorinated Organic Acid Compounds in Water by Gas Chromatography with an
Electron Capture Detector
", approved 2020, referenced in Section
611.645.
"ASTM D5673-03" means "Standard
Test Method for Elements in Water by Inductively Coupled Plasma-Mass
Spectrometry", approved 2003, referenced in Section 611.720.
"ASTM D5673-05" means "Standard
Test Method for Elements in Water by Inductively Coupled Plasma-Mass
Spectrometry", approved 2005, referenced in Section 611.720.
"ASTM D5673-10" means "Standard
Test Method for Elements in Water by Inductively Coupled Plasma-Mass
Spectrometry", approved 2010, referenced in Section 611.720.
"ASTM D5673-16" means "Standard
Test Method for Elements in Water by Inductively Coupled Plasma-Mass
Spectrometry", approved 2016, referenced in Section 611.720
Plasma-Mass
Spectrometry", approved 2005, referenced in Section 611.720.
"ASTM D5673-10" means "Standard
Test Method for Elements in Water by Inductively Coupled Plasma-Mass
Spectrometry", approved 2010, referenced in Section 611.720.
"ASTM D5673-16" means "Standard
Test Method for Elements in Water by Inductively Coupled Plasma-Mass
Spectrometry", approved 2016, referenced in Section 611.720.
"ASTM D6239-09" means "Standard
Test Method for Uranium in Drinking Water by High-Resolution
Alpha-Liquid-Scintillation Spectrometry", approved 2009, referenced in
Section 611.720.
"ASTM D6508-00(2005)"
means "Standard Test Method for Determination of Dissolved Inorganic
Anions in Aqueous Matrices Using Capillary Ion Electrophoresis and Chromate
Electrolyte", approved 2000 (revised 2005), referenced in Section 611.611.
"ASTM D6508-15" means "Standard
Test Method for Determination of Dissolved Inorganic Anions in Aqueous Matrices
Using Capillary Ion Electrophoresis and Chromate Electrolyte", approved
2015, referenced in Section 611.611.
"ASTM D6581-00" means "Standard
Test Method for Bromate, Bromide, Chlorate, and Chlorite in Drinking Water by
Chemically Suppressed Ion Chromatography", approved 2000, referenced in
Section 611.381.
"ASTM D6581-08 A" means "Standard
Test Method for Bromate, Bromide, Chlorate, and Chlorite in Drinking Water by
Suppressed Ion Chromatography", "Test Method A − Chemically
Suppressed Ion Chromatography", approved 2008, referenced in Section
611.381.
"ASTM D6581-08 B" means "Standard
Test Method for Bromate, Bromide, Chlorate, and Chlorite in Drinking Water by
Suppressed Ion Chromatography", "Test Method B − Electrolytically
Suppressed Ion Chromatography", approved 2008, referenced in Section
611.381.
"ASTM D6888-04" means "Standard
Test Method for Available Cyanide with Ligand Displacement and Flow Injection
Analysis (FIA) Utilizing Gas Diffusion Separation and Amperometric Detection",
approved 2004, referenced in Section 611.611
rinking Water by
Suppressed Ion Chromatography", "Test Method B − Electrolytically
Suppressed Ion Chromatography", approved 2008, referenced in Section
611.381.
"ASTM D6888-04" means "Standard
Test Method for Available Cyanide with Ligand Displacement and Flow Injection
Analysis (FIA) Utilizing Gas Diffusion Separation and Amperometric Detection",
approved 2004, referenced in Section 611.611.
"ASTM D6919-03" means "Standard
Test Method for Determination of Dissolved Alkali and Alkaline Earth Cations
and Ammonium in Water and Wastewater by Ion Chromatography", approved
2003, referenced in Section 611.611.
"ASTM D6919-09" means "Standard
Test Method for Determination of Dissolved Alkali and Alkaline Earth Cations
and Ammonium in Water and Wastewater by Ion Chromatography", approved
2009, referenced in Section 611.611.
"ASTM D6919-17" means "Standard
Test Method for Determination of Dissolved Alkali and Alkaline Earth Cations
and Ammonium in Water and Wastewater by Ion Chromatography", approved
2017, referenced in Section 611.611.
"ASTM D7283-17" means "Standard
Test Method for Alpha and Beta Activity in Water by Liquid Scintillation
Counting", approved 2017, referenced in Section 611.720.
"ATI Orion Technical Bulletin
601 (94)" means "Standard Method of Testing for Nitrate in Drinking
Water" (July 1994), Part Number 221890-001. Available from Thermo-Fisher
Scientific, 168 Third Ave, Waltham, MA 02451 (800-556-2323;
www.thermofisher.com). Referenced in Section 611.611.
"Charm Fast Phage (12)"
means "Fast Phage Test: Presence/Absence for Coliphage in Ground Water
with Same Day Positive Prediction", ATP Case No. D09-0007, Version 009
(November 28, 2012). Available from Charm Sciences, Inc., 659 Andover St.,
Lawrence, MA 01843-1032. Referenced in Section 611.802 and USEPA, OGWDW
(under "Ground Water Rule (PDF)").
"Chromocult
®
eferenced in Section 611.611.
"Charm Fast Phage (12)"
means "Fast Phage Test: Presence/Absence for Coliphage in Ground Water
with Same Day Positive Prediction", ATP Case No. D09-0007, Version 009
(November 28, 2012). Available from Charm Sciences, Inc., 659 Andover St.,
Lawrence, MA 01843-1032. Referenced in Section 611.802 and USEPA, OGWDW
(under "Ground Water Rule (PDF)").
"Chromocult
®
(00)"
means "Chromocult® Coliform Agar Presence/Absence Membrane Filter Test
Method for Detection and Identification of Coliform Bacteria and Escherichia
coli in Finished Waters", Version 1.0 (November 2000). Available from EMD
Millipore (division of Merck KGgA, Darmstadt, Germany), 290 Concord Road,
Billerica, MA 01821 (800-645-5476 or 781-533-6000) and USEPA, OGWDW (under "Ground
Water Rule (PDF)" and "Revised Total Coliforms Rules (PDF)").
Referenced in Sections 611.802 and 611.1052.
"E*Colite (98)" means "Alternative
Test Procedure Case #D95-0007: Charm E*Colite Presence/Absence Test for
Detection and Identification of Coliform Bacteria and Escherichia coli in
Drinking Water" (January 9, 1998). Available from Charm Sciences, Inc.,
659 Andover St., Lawrence, MA 01843–1032 and USEPA, OGWDW (under "Ground
Water Rule (PDF)" and "Revised Total Coliforms Rules (PDF)").
Referenced in Sections 611.802 and 611.1052.
EML Methods. Available from
USEPA, OGWDW (listed under "Radionuclides (PDF)" by individual method
numbers).
EML (90). In "EML Procedures
Manual", HASL 300, Volumes 1 and 2, 27
th
ed. (November 1990).
"EML (90) Ga-01" means
section 4.5.2.3, Ga-01, "Gamma Radioassay", in section 4.5.2.3, "Radiometrology",
in 27
th
ed. Referenced in Section 611.720. USEPA, OGWDW lists EML
.802 and 611.1052.
EML Methods. Available from
USEPA, OGWDW (listed under "Radionuclides (PDF)" by individual method
numbers).
EML (90). In "EML Procedures
Manual", HASL 300, Volumes 1 and 2, 27
th
ed. (November 1990).
"EML (90) Ga-01" means
section 4.5.2.3, Ga-01, "Gamma Radioassay", in section 4.5.2.3, "Radiometrology",
in 27
th
ed. Referenced in Section 611.720. USEPA, OGWDW lists EML
(90) Ga-01 as "4.5.2.3".
"EML (90) Ra-05" means
Ra-05, "Radium-226 in Tap Water, Urine, and Feces", in section 4.5.4,
"Radiochemical", in 27
th
ed. Referenced in Section
611.720.
"EML (90) Sr-01" means
Sr-01, "Strontium-89", in section 4.5.4, "Radiochemical",
in 27
th
ed. Referenced in Section 611.720.
"EML (90) Sr-02" means
Sr-02, "Strontium-90", in section 4.5.4, "Radiochemical",
in 27
th
ed. Referenced in Section 611.720.
"EML (90) U-02" means
U-02, "Isotopic Uranium in Biological and Environmental Materials",
in section 4.5.4, "Radiochemical", in 27
th
ed.
"EML (90) U-04" means
U-04, "Uranium in Biological and Environmental Materials", in section
4.5.4, "Radiochemical", in 27
th
ed. Referenced in Section
611.720.
EML (97). In "EML Procedures
Manual", HASL 300, Volumes 1 and 2, 28
th
ed., Revision 0
(February 1997). Currently available on-line from United States Department of
Homeland Security, Science and Technology Directorate (formerly United States
Department of Energy, Environmental Measurements Laboratory) (https://www.hsdl.org/c/view?docid=487142).
"EML (97) Ga-01-R" means
Ga-01-R, "Gamma Radioassay", in section 4.5.2, "Radiometrology",
in 28
th
ed. Referenced in Section 611.720.
"EML (97) Ra-04" means
Ra-04-RC, "Radium-226 in Tap Water, Urine, and Feces", in section
4.5.4, "Radiochemical", in 28
th
ed. Referenced in Section
611.720.
"EML (97) Sr-01" means
Sr-01-RC, "Strontium-89", in section 4.5.4, "Radiochemical",
in 28
th
ed. Referenced in Section 611.720.
"EML (97) Sr-02" means
Sr-02-RC, "Strontium-90", in section 4.5.4, "Radiochemical",
in 28
th
ed
n 611.720.
"EML (97) Ra-04" means
Ra-04-RC, "Radium-226 in Tap Water, Urine, and Feces", in section
4.5.4, "Radiochemical", in 28
th
ed. Referenced in Section
611.720.
"EML (97) Sr-01" means
Sr-01-RC, "Strontium-89", in section 4.5.4, "Radiochemical",
in 28
th
ed. Referenced in Section 611.720.
"EML (97) Sr-02" means
Sr-02-RC, "Strontium-90", in section 4.5.4, "Radiochemical",
in 28
th
ed. Referenced in Section 611.720.
"EML (97) U-02" means
U-02-RC, "Isotopic Uranium in Biological and Environmental Materials",
in section 4.5.4, "Radiochemical", in 28
th
ed.
"EML (97) U-04" means
U-04-RC, "Uranium in Biological and Environmental Materials", in
section 4.5.4, "Radiochemical", in 28
th
ed. Referenced in
Section 611.720.
"Enterolert (96)" means "Evaluation
of Enterolert for Enumeration of Enterococci in Recreational Waters",
Applied and Environmental Microbiology, Oct. 1996, vol. 62, no. 10, p. 3881.
Available from American Society for Microbiology, 1752 N Street N.W.,
Washington, DC 20036 (202-737-3600; https://journals.asm.org/doi/epdf/10.1128/aem.62.10.3881-3884.1996).
Referenced in Section 611.802.
BOARD NOTE: In 40 CFR
141.402(c)(2), USEPA approved the method the above literature review describes.
The method itself is in the printed instructions to the proprietary kit
available from IDEXX Laboratories, Inc., One IDEXX Drive, Westbrook, Maine
04092 (800-548-6733); https://www.idexx.com/en/water/water-products-services/enterolert/.
ASTM approved the method as "Standard Test Method for Enterococci in Water
Using Enterolert
™
", which is available in two versions from
ASTM: ASTM D6503-99 and ASTM D6503-99(2005). While it is more conventional to
incorporate by reference the method as presented in the
kit instructions or as approved by ASTM
, the Board is constrained to
incorporate by reference the version that USEPA explicitly approves, which is
the version the technical literature describes
er
Using Enterolert
™
", which is available in two versions from
ASTM: ASTM D6503-99 and ASTM D6503-99(2005). While it is more conventional to
incorporate by reference the method as presented in the
kit instructions or as approved by ASTM
, the Board is constrained to
incorporate by reference the version that USEPA explicitly approves, which is
the version the technical literature describes.
"Georgia Radium (04)"
means "Method for the Determination of Radium-226 and Radium-228 in
Drinking Water by Gamma-ray Spectrometry Using HPGE or Ge(Li) Detectors",
Revision 1.2 (December 2004). Available from Georgia Tech Research Institute,
Robert Rosson, 925 Dalney Road, Atlanta, GA 30332 (404-407-6339) and USEPA,
OGWDW (under "Radionuclides (PDF)"). Referenced in Section 611.720.
"GLI Method 2 (92)"
means "Turbidity GLI Method 2" (November 2, 1992). Available from
Great Lakes Instruments, Inc., 8855 North 55
th
Street, Milwaukee, WI
53223. Also available from USEPA, OGWDW
(under "Surface
Water Treatment Rule (PDF)")
. Referenced in Section 611.531.
"Guidance Manual for
Filtration and Disinfection (91)" means "Guidance Manual for
Compliance with the Filtration and Disinfection Requirements for Public Water
Systems Using Surface Water Sources" (March 1991), EPA 570/3-91-001,
USEPA, Office of Drinking Water, Criteria and Standards Division, Science and
Technology Branch. Available from NTRL (document number PB93-222933) and
USEPA, NSCEP (search "570391001"). Referenced in Sections 611.111
and 611.212.
Hach Methods. Available from Hach
Company, P.O. Box 389, Loveland, CO 80539-0389 (800-227-4224 or www.hach.com).
"Hach 8026 (15)" means
Hach Method 8026, "Spectrophotometric Measurement of Copper in Finished
Drinking Water", Revision 1.2 (December 2015). Referenced in Section
611.611.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Inorganic Contaminants and Other Inorganic
Constituents (PDF)")
. Available from Hach
Company, P.O. Box 389, Loveland, CO 80539-0389 (800-227-4224 or www.hach.com).
"Hach 8026 (15)" means
Hach Method 8026, "Spectrophotometric Measurement of Copper in Finished
Drinking Water", Revision 1.2 (December 2015). Referenced in Section
611.611.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Inorganic Contaminants and Other Inorganic
Constituents (PDF)").
"Hach 8195 (18)" means
Hach Method 8195, "Determination of Turbidity by Nephelometry",
Revision 3.0 (March 2018). Referenced in Section 611.531.
"Hach 10029 (99)
(m-ColiBlue24
®
)" means m-ColiBlue24
®
Test, Method No. 10029, "Total Coliforms and E. coli Membrane Filtration
Method with m-ColiBlue24
®
Broth", Revision 2 (August 17, 1999),
document number DOC316.53.001213. Referenced in Sections 611.802 and 611.1052.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Ground Water Rule (PDF)").
"Hach 10133 (00) (FilterTrak)"
means Hach FilterTrak Method 10133, "Determination of Turbidity by Laser
Nephelometry", Revision 2.0 (January 7, 2000) in Appendix A of "Introduction
to Laser Nephelometry: An Alternative to Conventional Particulate Analysis
Methods". Referenced in Section 611.531.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Surface Water Treatment Rule (PDF)").
"Hach 10206 (11) (TNTplus 835/836)"
means Hach TNTplus 835/836 Method 10206, "Spectrophotometric Measurement
of Nitrate in Water and Wastewater", Revision 2.0 (January 2011).
Referenced in Section 611.611.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Inorganic Contaminants and Other Inorganic
Constituents (PDF)").
"Hach 10225 (11) (SPADNS 2)"
means Hach SPADNS 2 Method 10225, "Fluoride, USEPA SPADNS 2 Method 10225",
Revision 2.0 (January 2011). Referenced in Section 611.611.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Inorganic Contaminants and Other Inorganic
Constituents (PDF)")
OTE: Also available from
USEPA, OGWDW (under "Inorganic Contaminants and Other Inorganic
Constituents (PDF)").
"Hach 10225 (11) (SPADNS 2)"
means Hach SPADNS 2 Method 10225, "Fluoride, USEPA SPADNS 2 Method 10225",
Revision 2.0 (January 2011). Referenced in Section 611.611.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Inorganic Contaminants and Other Inorganic
Constituents (PDF)").
"Hach 10241 (15)" means
Hach Method 10241, "Spectrophotometric Measurement of Free Chlorine (Cl2)
in Finished Drinking Water", Revision 1.2 (November 2015). Referenced in Sections
611.381 and 611.531.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Disinfection Byproduct Rules (PDF)").
"Hach 10258 (16)" means
Hach Method 10258, "Determination of Turbidity by 360° Nephelometry",
Revision 1.0 (January 2016). Referenced in Section 611.531.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Surface Water Treatment Rule (PDF)").
"Hach 10258 (18)" means
Hach Method 10258, "Determination of Turbidity by 360° Nephelometry",
Revision 2.0 (March 2018). Referenced in Section 611.531.
"Hach 10260 (13)" means
Hach Method 10260, "Determination of Chlorinated Oxidants (Free and Total)
in Water Using Disposable Planar Reagent-filled Cuvettes and Mesofluic Channel
Colorimetry" (April 2013). Referenced in Sections 611.381 and 611.531.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Disinfection Byproduct Rules (PDF)").
"Hach 10261 (15)" means
Hach Method 10261, "Total Organic Carbon in Finished Drinking Water by
Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis", Revision
1.2 (December 2015). Referenced in Section 611.381.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Disinfection Byproduct Rules (PDF)").
"Hach 10267 (15)" means
Hach Method 10267, "Spectrophotometric Measurement of Total Organic Carbon
(TOC) in Finished Drinking Water", Revision 1.2 (December 2015).
Referenced in Section 611.381
Hydroxyl Radical Oxidation Infrared Analysis", Revision
1.2 (December 2015). Referenced in Section 611.381.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Disinfection Byproduct Rules (PDF)").
"Hach 10267 (15)" means
Hach Method 10267, "Spectrophotometric Measurement of Total Organic Carbon
(TOC) in Finished Drinking Water", Revision 1.2 (December 2015).
Referenced in Section 611.381.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Disinfection Byproduct Rules (PDF)").
"Hach 10272 (15)" means
Hach Method 10272, "Spectrophotometric Measurement of Copper in Finished
Drinking Water", Revision 1.2 (December 2015). Referenced in Section
611.611.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Inorganic Contaminants and Other Inorganic
Constituents (PDF)").
"Hach 10312 (22)" means
Hach Method 10312, "Spectrophotometric Measurement of Flouride in Finished
Drinking Water Aluminum -Chromeazurol S Complex (AL-CAS) Using Planar
Reagent-filled Cuvettes," Revision 1.0 (August 2022). Referenced in
Section 611.611.
"ITS D99-003 (03)" means
"Method # (D99-003): Free Chlorine Species (HOCl- and OCl-) by Test Strip",
Revision 3.0 (November 21, 2003). Available from Industrial Test Systems,
Inc., 1875 Langston St., Rock Hill, SC 29730 (803-329-2999) and USEPA, OGWDW
(under "Disinfection Byproduct Rules (PDF)"). Referenced in Section
611.381.
"Kelada 01 (01)" means "Method
Kelada-01: Kelada Automated Test Methods for Total Cyanide, Acid Dissociable
Cyanide, and Thiocyanate", Revision 1.2 (August 2001), USEPA Office of Water,
document number EPA 821/B-01-009. Available from NTRL
(document
number PB2001-108275)
and USEPA, OGWDW (under "Inorganic
Contaminants and Other Inorganic Constituents (PDF)")
. Referenced in
Section 611.611.
Lovibond Methods. Available from
Tintometer, Inc., 6456 Parkland Drive, Sarasota, FL 34243 (800-922-5242,
941-758-6410, or www.lovibond.us) and USEPA, OGWDW (under "Surface Water
Treatment Rule (PDF)")
821/B-01-009. Available from NTRL
(document
number PB2001-108275)
and USEPA, OGWDW (under "Inorganic
Contaminants and Other Inorganic Constituents (PDF)")
. Referenced in
Section 611.611.
Lovibond Methods. Available from
Tintometer, Inc., 6456 Parkland Drive, Sarasota, FL 34243 (800-922-5242,
941-758-6410, or www.lovibond.us) and USEPA, OGWDW (under "Surface Water
Treatment Rule (PDF)").
"Lovibond PTV 1000 (16)"
means "Continuous Measurement of Drinking Water Turbidity Using a Lovibond
PTV 1000 White Light LED Turbidimeter", Revision 1.0 (December 20, 2016).
Referenced in Section 611.531.
"Lovibond PTV 2000 (16)"
means "Continuous Measurement of Drinking Water Turbidity Using a Lovibond
PTV 2000 660-nm LED Turbidimeter", Revision 1.0 (December 20, 2016).
Referenced in Section 611.531.
"Lovibond
TB 3500 (21)" means "Measurement of Drinking Water Turbidity of a
Captured Sample Using a Lovibond White Light LED Portable Turbidimeter",
Revision 1.0 (2021). Referenced in Section 611.531.
"Lovibond TB 5000 (21)"
means "Measurement of Drinking Water Turbidity of a Captured Sample Using
a Lovibond 660-nm LED Portable Turbidimeter", Revision 1.0 (2021).
Referenced in Section 611.531.
"Lovibond PTV 6000 (16)"
means "Continuous Measurement of Drinking Water Turbidity Using a Lovibond
PTV 6000 Laser Turbidimeter", Revision 1.0 (December 20, 2016).
Referenced in Section 611.531.
"Lovibond TB 6000 (21)"
means "Measurement of Drinking Water Turbidity of a Captured Sample Using
a Lovibond Portable Laser Turbidimeter", Revision 1.0 (2021). Referenced
in Section 611.531.
Maine Methods. Available from
Maine Health and Environmental Testing Laboratory, 221 State Street, Augusta,
ME 04333 (207-287-2727).
"ME355.01 (09)" means "Determination
of Cyanide in Drinking Water by GC/MS Headspace Analysis", Revision 1 (May
26, 2009). Referenced in Section 611.611. Also available from NEMI and USEPA,
OGWDW (under "Inorganic Contaminants and Other Inorganic Constituents
(PDF)")
ods. Available from
Maine Health and Environmental Testing Laboratory, 221 State Street, Augusta,
ME 04333 (207-287-2727).
"ME355.01 (09)" means "Determination
of Cyanide in Drinking Water by GC/MS Headspace Analysis", Revision 1 (May
26, 2009). Referenced in Section 611.611. Also available from NEMI and USEPA,
OGWDW (under "Inorganic Contaminants and Other Inorganic Constituents
(PDF)").
"ME 531 (19)" means "Measurement
or N-Methylcarbamoyloximes and N-Methylcarbamates in Drinking Water by LC-MS/MS",
version 1.0 (September 2019). Referenced in Section 611.645.
"Method 537.1", Version
2.0: Determination of Selected Per- and Polyfluorinated Alkyl Substances in
Drinking Water by Solid Phase Extraction and Liquid Chromatography/Tandem Mass
Spectrometry (LC/MS/MS), EPA/600/R-20/006, March 2020
Mitchell Methods. Available from
Leck Mitchell, PhD, PE, 656 Independence Valley Dr., Grand Junction, CO 81507
(920-244-8661); , NEMI (except for Mitchell M5331 (16)); and USEPA, OGWDW
(under "Surface Water Treatment Rule (PDF)").
"Mitchell M5271 (09)"
means Mitchell Method M5271, "Determination of Turbidity by Laser
Nephelometry", Revision 1.1 (March 5, 2009). Referenced in Section
611.531.
"Mitchell M5331 (09)"
means Mitchell Method M5331, "Determination of Turbidity by Laser
Nephelometry", Revision 1.1 (March 2009). Referenced in Section 611.531.
"Mitchell M5331 (16)"
means Mitchell Method M5331, "Determination of Turbidity by Laser
Nephelometry", Revision 1.2 (February 2016). Referenced in Section
611.531.
"Modified Colitag
™
March 5, 2009). Referenced in Section
611.531.
"Mitchell M5331 (09)"
means Mitchell Method M5331, "Determination of Turbidity by Laser
Nephelometry", Revision 1.1 (March 2009). Referenced in Section 611.531.
"Mitchell M5331 (16)"
means Mitchell Method M5331, "Determination of Turbidity by Laser
Nephelometry", Revision 1.2 (February 2016). Referenced in Section
611.531.
"Modified Colitag
™
(09)" means "Modified Colitag
™
Test Method for
Simultaneous Detection of E. coli and other Total Coliforms in Water",
(ATP D05-0035) (August 28, 2009). Available from CPI International, Inc., 5580
Skylane Blvd., Santa Rosa, CA 95403 (800-878-7654; www.cpiinternational.com);
NEMI; and USEPA, OGWDW (under "Ground Water Rule (PDF)" and "Revised
Totasl Coliforms Rules (PDF)"). Referenced in Sections 611.802 and
611.1052.
"Modified Colitag™ (20)"
means "Modified Colitag™ Test Method for Simultaneous Detection of Total
Coliforms and E. coli in Water", Version 2.0, (June 2020). Available from
Neogen Corporation, 620 Lesher Place, Lansing, MI 48912. Referenced in
Sections 611.802 and 611.1052.
"NBS Handbook 69 (63)"
means "Maximum Permissible Body Burdens and Maximum Permissible
Concentrations of Radionuclides in Air and in Water for Occupational Exposure"
(August 1963), U.S. Department of Commerce, National Bureau of Standards.
Available from U.S. Nuclear Regulatory Commission, One White Flint North, 115
Rockville Pike, Rockville, MD 20852-2738; https://www.nrc.gov/docs/ML2020/ML20206L091.pdf
or Oak Ridge Associated Universities (ORAU), 100 ORAU Way, Oak Ridge, TN 37830
(865-576-3146);
https://www.orau.org/health-physics-museum/files/library/nbs/nbs-69.pdf.
Referenced in Sections 611.101 and 611.330.
BOARD NOTE: The 1963 version of
National Bureau of Standards Handbook 69 modifies the 1959 publication of the
National Committee on Radiation Protection, NCRP Report No. 22, of the same
title. The version available on the NCRP website is the 1959 document
30
(865-576-3146);
https://www.orau.org/health-physics-museum/files/library/nbs/nbs-69.pdf.
Referenced in Sections 611.101 and 611.330.
BOARD NOTE: The 1963 version of
National Bureau of Standards Handbook 69 modifies the 1959 publication of the
National Committee on Radiation Protection, NCRP Report No. 22, of the same
title. The version available on the NCRP website is the 1959 document.
"NECi Nitrate Reductase (06)"
means "Method for Nitrate Reductase Nitrate-Nitrogen Analysis of Drinking
Water", Version 1.0, Revision 2.0 (February 1, 2016). Available from
Superior Enzymes Inc., 334 Hecla Street, Lake Linden, Michigan 49945
(906-296-1115). Also available from USEPA, OGWDW (under "Inorganic
Contaminants and Other Inorganic Constituents (PDF)"). Referenced in
Section 611.611.
"New Jersey Radium (90)"
means "Determination of Ra-228 in Drinking Water" (August 1990), New
Jersey Department of Environmental Protection, Division of Environmental
Quality, Bureau of Radiation and Inorganic Analytical Services. Available from
publisher, 9 Ewing Street, Trenton, NJ 08625. Referenced in Section 611.720.
"New York Radium (82)"
means "Determination of 226Ra and 228Ra, Ra-02" (January 1980,
revised June 1982), Radiological Sciences Institute, Center for Laboratories
and Research, New York State Department of Health. Available from publisher,
Empire State Plaza, Albany, NY 12201. Referenced in Section 611.720.
"OIA-1677 (04)" means "Method
OIA-1677 DW, Available Cyanide by Flow Injection, Ligand Exchange, and
Amperometry" (January 2004), document number EPA 821/R-04/001. Referenced
in Section 611.611. Available from; USEPA, NSCEP (search "821R04001");
and USEPA, OGWDW (under "Inorganic Contaminants and Other Inorganic
Constituents (PDF)").
"Orion AQ4500 (09)"
means "Determination of Turbidity by LED Nephelometry", Revision 5
(March 12, 2009)
lable Cyanide by Flow Injection, Ligand Exchange, and
Amperometry" (January 2004), document number EPA 821/R-04/001. Referenced
in Section 611.611. Available from; USEPA, NSCEP (search "821R04001");
and USEPA, OGWDW (under "Inorganic Contaminants and Other Inorganic
Constituents (PDF)").
"Orion AQ4500 (09)"
means "Determination of Turbidity by LED Nephelometry", Revision 5
(March 12, 2009). Available from
Thermo-Fisher
Scientific, 168 Third Ave, Waltham, MA 02451 (800-556-2323 or
www.thermofisher.com); NEMI; and USEPA, OGWDW (under "Surface Water
Treatment Rule (PDF)").
Referenced in Section 611.531.
Palintest Methods. Available from
Palintest, Ltd., 600 Corporate Circle, Suite F, Golden, CO 80401
(720-221-6878).
"Palintest 1001 (99)"
means "Method 1001: Lead in Drinking Water by Differential Pulse Anodic
Stripping Voltammetry", August 1999, referenced in Section 611.611.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Inorganic Contaminants and Other Inorganic
Constituents (PDF)").
"Palintest 1001 (20)"
means "Method 1001: Lead in Drinking Water by Differential Pulse Anodic
Stripping Voltammetry", May 2020, Revision 1.1, referenced in Section
611.611.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Inorganic Contaminants and Other Inorganic
Constituents (PDF)").
"Palintest ChlordioX Plus
(13)" means "Chlorine Dioxide and Chlorite in Drinking Water by
Amperometry using Disposable Sensors", November 2013, referenced in
Sections 611.381 and 611.531.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Disinfection Byproduct Rules
(PDF)")
.
"Palintest ChlordioX Plus
USEPA, OGWDW (under "Inorganic Contaminants and Other Inorganic
Constituents (PDF)").
"Palintest ChlordioX Plus
(13)" means "Chlorine Dioxide and Chlorite in Drinking Water by
Amperometry using Disposable Sensors", November 2013, referenced in
Sections 611.381 and 611.531.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Disinfection Byproduct Rules
(PDF)")
.
"Palintest ChlordioX Plus
(20)" means "Chlorine Dioxide and Chlorite in Drinking Water by
Amperometry using Disposable Sensors", Version 1.1 (February 2020),
referenced in Sections 611.381 and 611.531.
"Palintest ChloroSense (09)"
means "Measurement of Free and Total Chlorine in Drinking Water by
Palintest ChloroSense", September 2009, referenced in Sections 611.381 and
611.531. BOARD NOTE: Also available from NEMI and USEPA, OGWDW (under "Disinfection
Byproduct Rules (PDF)").
"Palintest ChloroSense (20)"
means "Free and Total Chlorine in Drinking Water by Amperometry using
disposable sensors", Revision 1.1 (February 2020), referenced in Sections
611.381 and 611.531.
"QuikChem 10-204-00-1-X (00)"
means "Digestion and distillation of total cyanide in drinking and
wastewaters using MICRO DIST and determination of cyanide by flow injection
analysis", Revision 2.1 (November 30, 2000). Available from Lachat
Instruments, 6645 W. Mill Rd., Milwaukee, WI 53218 (414–358–4200) and USEPA,
OGWDW (under
"Inorganic Contaminants and Other
Inorganic Constituents (PDF)
"). Referenced in Section 611.611.
"RAPID'E. coli (20)"
means "Simultaneous Detection of Total Coliform Bacteria and Escherichia
coli Using RAPID'E. coli 2 (REC2) in Drinking Water" (May 2020).
Available from Bio-Rad Laboratories, 2000 Nobel Drive, Hercules, California
94547. Referenced in Sections 611.802 and 611.1052.
"Readycult
®
anic Contaminants and Other
Inorganic Constituents (PDF)
"). Referenced in Section 611.611.
"RAPID'E. coli (20)"
means "Simultaneous Detection of Total Coliform Bacteria and Escherichia
coli Using RAPID'E. coli 2 (REC2) in Drinking Water" (May 2020).
Available from Bio-Rad Laboratories, 2000 Nobel Drive, Hercules, California
94547. Referenced in Sections 611.802 and 611.1052.
"Readycult
®
(07)"
means "Readycult Coliforms 100 Presence/Absence Test for Detection and Identification
of Coliform Bacteria and Escherichia coli in Finished Waters", Version 1.1
(January 2007). Available from
EMD Millipore (division
of Merck KGgA, Darmstadt, Germany), 290 Concord Road, Billerica, MA 01821
(800-645-5476 or 781-533-6000) and USEPA, OGWDW (under "Ground Water Rule
(PDF)" and "Revised Total Coliforms Rules (PDF)").
Referenced in Sections 611.802 and 611.1052.
"SimPlate (00)" means "IDEXX
SimPlate
™
HPC Test Method for Heterotrophs in Water" (November
29, 2000). Available from IDEXX Laboratories, Inc., One IDEXX Drive,
Westbrook, Maine 04092 (800-548-6733). Referenced in Section 611.531.
SM Methods. Approved as the
version in the indicated editions of "Standard Methods for the Examination
of Water and Wastewater". Available from the American Public Health
Association, 800 I Street NW, Washington, DC 20005, 202-777-2742; American
Water Works Association, 6666 West Quincy Ave., Denver, CO 80235, 303-794-7711,
Water Environment Federation, 601 Wythe Street, Alexandria, VA 22314,
800-666-0206, www.wef.org; or Standard Methods Online, 800-633-4931,
www.standardmethods.org.
BOARD NOTE: The Board did not
separately list versions of methods from Standard Methods Online also appearing
in a printed edition. Using a method in the approved version as available from
Standard Methods Online is acceptable.
"SM 302
nvironment Federation, 601 Wythe Street, Alexandria, VA 22314,
800-666-0206, www.wef.org; or Standard Methods Online, 800-633-4931,
www.standardmethods.org.
BOARD NOTE: The Board did not
separately list versions of methods from Standard Methods Online also appearing
in a printed edition. Using a method in the approved version as available from
Standard Methods Online is acceptable.
"SM 302
(71)
" means Method 302, "Gross Alpha and Gross Beta Radioactivity
in Water (Total, Suspended, and Dissolved)", only the version in the 13
th
edition. Referenced in Section 611.720.
"SM 303 (71)" means
Method 303, "Total Radioactive Strontium and Strontium 90 in Water",
only the version in the 13
th
edition. Referenced in Section
611.720.
"SM 304 (71)" means
Method 304, "Radium in Water by Precipitation", only the version in
the 13
th
edition. Referenced in Section 611.720.
"SM 305 (71)" means
Method 305, "Radium 226 by Radon in Water (Soluble, Suspended, and Total)",
only the version in the 13
th
edition. Referenced in Section
611.720.
"SM 306 (71)" means Method
306, "Tritium in Water", in "Standard Methods for the
Examination of Water and Wastewater", only the version in the 13
th
edition. Referenced in Section 611.720.
"SM 2130 B (88)" means
Method 2130 B, "Turbidity", "Nephelometric Method", only
the version in the 18
th
edition. Referenced in Section 611.531.
"SM 2130 B (94)" means
Method 2130 B, "Turbidity", "Nephelometric Method", only
the version in the 19
th
and 20
th
editions. Referenced in
Section 611.531.
"SM 2130 B (01)" means
Method 2130 B, "Turbidity", "Nephelometric Method", only
the version in the 21
st
, 22
nd
, 23
rd
, and 24
th
editions. Referenced in Section 611.531.
"SM 2320 B (91)" means
Method 2320 B, "Alkalinity", "Titration Method", only the
version in the 18
th
and 19
th
editions. Referenced in
Section 611.611.
"SM 2320 B (97)" means
Method 2320 B, "Alkalinity", "Titration Method", only the
version in the 20
th
, 21
st
, 22
nd
, 23
rd
,
and 24
th
, editions
version in the 21
st
, 22
nd
, 23
rd
, and 24
th
editions. Referenced in Section 611.531.
"SM 2320 B (91)" means
Method 2320 B, "Alkalinity", "Titration Method", only the
version in the 18
th
and 19
th
editions. Referenced in
Section 611.611.
"SM 2320 B (97)" means
Method 2320 B, "Alkalinity", "Titration Method", only the
version in the 20
th
, 21
st
, 22
nd
, 23
rd
,
and 24
th
, editions. Referenced in Section 611.611.
"SM 2510 B (91)" means
Method 2510 B, "Conductivity", "Laboratory Method", only
the version in the 18
th
and 19
th
editions. Referenced in
Section 611.611.
"SM 2510 B (97)" means
Method 2510 B, "Conductivity", "Laboratory Method", only
the version in the 20
th
, 21
st
, 22
nd
, 23
rd
,
and 24
th
editions. Referenced in Section 611.611.
"SM 2550 (88)" means
Method 2550, "Temperature, Laboratory and Field Methods", only the
version in the 18
th
edition. Referenced in Section 611.611.
"SM 2550 (93)" means
Method 2550, "Temperature, Laboratory and Field Methods", only the
version in the 19
th
and 20
th
editions. Referenced in
Section 611.611.
"SM 2550 (00)" means
Method 2550, "Temperature, Laboratory and Field Methods", only the
version in the 21
st
edition. Referenced in Section 611.611.
"SM 2550 (10)" means
Method 2550, "Temperature, Laboratory and Field Methods", only the
version in the 22
nd
, 23
rd
, and 24
th
editions.
Referenced in Section 611.611.
"SM 3111 B (89)" means
Method 3111 B, "Metals by Flame Atomic Absorption Spectrometry", "Direct
Air-Acetylene Flame Method", only the version in the 18
th
edition. Referenced in Sections 611.611 and 611.612.
"SM 3111 B (93)" means
Method 3111 B, "Metals by Flame Atomic Absorption Spectrometry", "Direct
Air-Acetylene Flame Method", only the version in the 19
th
edition. Referenced in Sections 611.611 and 611.612.
"SM 3111 B (99)" means
Method 3111 B, "Metals by Flame Atomic Absorption Spectrometry", "Direct
Air-Acetylene Flame Method" only the versions in the 21
st
, 22
nd
,
23
rd
, and 24
th
editions
111 B (93)" means
Method 3111 B, "Metals by Flame Atomic Absorption Spectrometry", "Direct
Air-Acetylene Flame Method", only the version in the 19
th
edition. Referenced in Sections 611.611 and 611.612.
"SM 3111 B (99)" means
Method 3111 B, "Metals by Flame Atomic Absorption Spectrometry", "Direct
Air-Acetylene Flame Method" only the versions in the 21
st
, 22
nd
,
23
rd
, and 24
th
editions. Referenced in Sections 611.611
and 611.612.
"SM 3111 D (89)" means
Method 3111 D, "Metals by Flame Atomic Absorption Spectrometry", "Direct
Nitrous Oxide-Acetylene Flame Method", only the version in the 19
th
edition. Referenced in Section 611.611.
"SM 3111 D (93)" means
Method 3111 D, "Metals by Flame Atomic Absorption Spectrometry", "Direct
Nitrous Oxide-Acetylene Flame Method", only the version in the 19
th
edition. Referenced in Section 611.611.
"SM 3111 D (99)" means
Method 3111 D, "Metals by Flame Atomic Absorption Spectrometry", "Direct
Nitrous Oxide-Acetylene Flame Method", only the version in the 21
st
,
22
nd
, 23
rd
, and 24
th
editions. Referenced in
Section 611.611.
"SM 3112 B (88)" means
Method 3112 B, "Metals by Cold-Vapor Atomic Absorption Spectrometry",
"Cold-Vapor Atomic Absorption Spectrometric Method", only the version
in the 18
th
edition. Referenced in Section 611.611.
"SM 3112 B (93)" means
Method 3112 B, "Metals by Cold-Vapor Atomic Absorption Spectrometry",
"Cold-Vapor Atomic Absorption Spectrometric Method", only the version
in the 19
th
edition. Referenced in Section 611.611.
"SM 3112 B (99)" means
Method 3112 B, "Metals by Cold-Vapor Atomic Absorption Spectrometry",
"Cold-Vapor Atomic Absorption Spectrometric Method", only the version
in the 21
st
edition. Referenced in Section 611.611.
"SM 3112 B (09)" means
Method 3112 B, "Metals by Cold-Vapor Atomic Absorption Spectrometry",
"Cold-Vapor Atomic Absorption Spectrometric Method", only the version
in the 22
nd
, 23
rd
, and 24
th
editions.
Referenced in Section 611.611
Atomic Absorption Spectrometry",
"Cold-Vapor Atomic Absorption Spectrometric Method", only the version
in the 21
st
edition. Referenced in Section 611.611.
"SM 3112 B (09)" means
Method 3112 B, "Metals by Cold-Vapor Atomic Absorption Spectrometry",
"Cold-Vapor Atomic Absorption Spectrometric Method", only the version
in the 22
nd
, 23
rd
, and 24
th
editions.
Referenced in Section 611.611.
"SM 3113 B (89)" means
Method 3113 B, "Metals by Electrothermal Atomic Absorption Spectrometry",
"Electrothermal Atomic Absorption Spectrometric Method", only the
version in the 18
th
edition. Referenced in Sections 611.611 and
611.612.
"SM 3113 B (93)" means
Method 3113 B, "Metals by Electrothermal Atomic Absorption Spectrometry",
"Electrothermal Atomic Absorption Spectrometric Method", only the
version in the 19
th
edition. (The same version appears in the 20th
edition but USEPA does not approve that edition.) Referenced in Sections
611.611 and 611.612.
"SM 3113 B (99)" means
Method 3113 B, "Metals by Electrothermal Atomic Absorption Spectrometry",
"Electrothermal Atomic Absorption Spectrometric Method", only the
version in the 21
st
edition. Referenced in Sections 611.611 and
611.612.
"SM 3113 B (04)" means
Method 3113 B, "Metals by Electrothermal Atomic Absorption Spectrometry",
"Electrothermal Atomic Absorption Spectrometric Method", only the
version from Standard Methods Online as Method 3113 B-04. Referenced in
Sections 611.611 and 611.612.
"SM 3113 B (10)" means
Method 3113 B, "Metals by Electrothermal Atomic Absorption Spectrometry",
"Electrothermal Atomic Absorption Spectrometric Method", only the
version in the 22
nd
, 23
rd
, and 24
th
editions.
Referenced in Sections 611.611 and 611.612.
"SM 3114 B (89)" means
Method 3114 B, "Metals by Hydride Generation/Atomic Absorption
Spectrometry", "Manual Hydride Generation/Atomic Absorption
Spectrometric Method", only the version in the 18
th
edition.
Referenced in Section 611.611
rothermal Atomic Absorption Spectrometric Method", only the
version in the 22
nd
, 23
rd
, and 24
th
editions.
Referenced in Sections 611.611 and 611.612.
"SM 3114 B (89)" means
Method 3114 B, "Metals by Hydride Generation/Atomic Absorption
Spectrometry", "Manual Hydride Generation/Atomic Absorption
Spectrometric Method", only the version in the 18
th
edition.
Referenced in Section 611.611.
"SM 3114 B (93)" means
Method 3114 B, "Metals by Hydride Generation/Atomic Absorption
Spectrometry", "Manual Hydride Generation/Atomic Absorption
Spectrometric Method", only the version in the 19
th
edition.
Referenced in Section 611.611.
"SM 3114 B (97)" means
Method 3114 B, "Metals by Hydride Generation/Atomic Absorption
Spectrometry", "Manual Hydride Generation/Atomic Absorption
Spectrometric Method", only the version in the 21
st
edition.
(The same version appears in the 20
th
edition, but USEPA does not approve
that edition.) Referenced in Section 611.611.
"SM 3114 B (09)" means
Method 3114 B, "Metals by Hydride Generation/Atomic Absorption
Spectrometry", "Manual Hydride Generation/Atomic Absorption
Spectrometric Method", only the version in the 22
nd
, 23
rd
,
and 24
th
editions. Referenced in Section 611.611.
"SM 3120 B (89)" means
Method 3120 B, "Metals by Plasma Emission Spectroscopy", "Inductively
Coupled Plasma (ICP) Method", only the version in the 18
th
edition. Referenced in Sections 611.611 and 611.612.
"SM 3120 B (93)" means
Method 3120 B, "Metals by Plasma Emission Spectroscopy", "Inductively
Coupled Plasma (ICP) Method", only the version in the 19
th
and
20
th
editions. Referenced in Sections 611.611 and 611.612.
"SM 3120 B (99)" means
Method 3120 B, "Metals by Plasma Emission Spectroscopy", "Inductively
Coupled Plasma (ICP) Method", only the version in the 21
st
, 22
nd
,
23
rd
, and 24
th
editions. Referenced in Sections 611.611
and 611.612
ission Spectroscopy", "Inductively
Coupled Plasma (ICP) Method", only the version in the 19
th
and
20
th
editions. Referenced in Sections 611.611 and 611.612.
"SM 3120 B (99)" means
Method 3120 B, "Metals by Plasma Emission Spectroscopy", "Inductively
Coupled Plasma (ICP) Method", only the version in the 21
st
, 22
nd
,
23
rd
, and 24
th
editions. Referenced in Sections 611.611
and 611.612.
"SM 3125 (97)" means
Method 3125, "Metals by Inductively Coupled Plasma/Mass Spectrometry",
only the version in the 20
th
and 21
st
editions.
Referenced in Section 611.720.
"SM 3500-Ca B (97)"
means Method 3500-Ca B, "Calcium", "EDTA Titrimetric Method",
only the version in the 20
th
, 21
st
, 22
nd
, 23
rd
,
and 24
th
editions. Referenced in Section 611.611.
"SM 3500-Ca D (91)"
means Method 3500-Ca D, "Calcium", "EDTA Titrimetric Method",
only the version in the 18
th
and 19
th
editions.
Referenced in Section 611.611.
"SM 3500-Mg B (97)"
means Method 3500-Mg B, "Magnesium", "Calculation Method",
only the version in the 20
th
, 21
st
, 22
nd
, 23
rd
,
and 24
th
editions. Referenced in Section 611.611.
"SM 3500-Mg E (90)"
means Method 3500-Mg E, "Magnesium", "Calculation Method",
only the version in the 18
th
edition. Referenced in Section
611.611.
"SM 3500-Mg E (91)"
means Method 3500-Mg E, "Magnesium", "Calculation Method",
only the version in the 19
th
edition. Referenced in Section
611.611.
"SM 4110 B (90)" means
Method 4110 B, "Determination of Anions by Ion Chromatography", "Ion
Chromatography with Chemical Suppression of Eluent Conductivity", only the
version in the 18
th
edition. Referenced in Section 611.611.
"SM 4110 B (91)" means
Method 4110 B, "Determination of Anions by Ion Chromatography", "Ion
Chromatography with Chemical Suppression of Eluent Conductivity", only the
version in the 19
th
edition. Referenced in Section 611.611
s by Ion Chromatography", "Ion
Chromatography with Chemical Suppression of Eluent Conductivity", only the
version in the 18
th
edition. Referenced in Section 611.611.
"SM 4110 B (91)" means
Method 4110 B, "Determination of Anions by Ion Chromatography", "Ion
Chromatography with Chemical Suppression of Eluent Conductivity", only the
version in the 19
th
edition. Referenced in Section 611.611.
"SM 4110 B (97)" means
Method 4110 B, "Determination of Anions by Ion Chromatography", "Ion
Chromatography with Chemical Suppression of Eluent Conductivity", only the
version in the 20
th
edition. Referenced in Section 611.611.
"SM 4110 B (00)" means
Method 4110 B, "Determination of Anions by Ion Chromatography", "Ion
Chromatography with Chemical Suppression of Eluent Conductivity", only the
version in the 21
st
, 22
nd
, 23
rd
, and 24
th
editions. Referenced in Section 611.611.
"SM 4500-Cl D (89)"
means Method 4500-Cl D, "Chlorine (Residual)", "Amperometric
Titration Method", only the version in the 18
th
edition.
Referenced in Section 611.531.
"SM 4500-Cl D (93)"
means Method 4500-Cl D, "Chlorine (Residual)", "Amperometric
Titration Method", only the version in the 19th and 20th editions.
Referenced in Sections 611.381 and 611.531.
"SM 4500-Cl D (00)"
means Method 4500-Cl D, "Chlorine (Residual)", "Amperometric
Titration Method", only the version in the 21
st
, 22
nd
,
23
rd
, and 24
th
editions. Referenced in Sections 611.381
and 611.531.
"SM 4500-Cl E (89)"
means Method 4500-Cl E, "Chlorine (Residual)", "Low-Level
Amperometric Titration Method", only the version in the 18
th
edition. Referenced in Section 611.531.
"SM 4500-Cl E (93)"
means Method 4500-Cl E, "Chlorine (Residual)", "Low-Level
Amperometric Titration Method", only the version in the 19
th
and 20
th
editions. Referenced in Sections 611.381 and 611.531
nd 611.531.
"SM 4500-Cl E (89)"
means Method 4500-Cl E, "Chlorine (Residual)", "Low-Level
Amperometric Titration Method", only the version in the 18
th
edition. Referenced in Section 611.531.
"SM 4500-Cl E (93)"
means Method 4500-Cl E, "Chlorine (Residual)", "Low-Level
Amperometric Titration Method", only the version in the 19
th
and 20
th
editions. Referenced in Sections 611.381 and 611.531.
"SM 4500-Cl E (00)"
means Method 4500-Cl E, "Chlorine (Residual)", "Low-Level
Amperometric Titration Method", only the version in the 21
st
,
22
nd
, 23
rd
, and 24
th
editions. Referenced in
Sections 611.381 and 611.531.
"SM 4500-Cl F (89)"
means Method 4500-Cl F, "Chlorine (Residual)", "DPD Ferrous
Titrimetric Method", only the version in the 18
th
edition.
Referenced in Section 611.531.
"SM 4500-Cl F (93)"
means Method 4500-Cl F, "Chlorine (Residual)", "DPD Ferrous
Titrimetric Method", only the version in the 19
th
and 20
th
editions. Referenced in Sections 611.381 and 611.531.
"SM 4500-Cl F (00)"
means Method 4500-Cl F, "Chlorine (Residual)", "DPD Ferrous
Titrimetric Method", only the version in the 21
st
, 22
nd
,
23
rd
, and 24
th
editions. Referenced in Sections 611.381
and 611.531.
"SM 4500-Cl G (89)"
means Method 4500-Cl G, "Chlorine (Residual)", "DPD Colorimetric
Method", only the version in the 18
th
edition. Referenced in
Section 611.531.
"SM 4500-Cl G (93)"
means Method 4500-Cl G, "Chlorine (Residual)", "DPD Colorimetric
Method", only the version in the 19
th
and 20
th
editions. Referenced in Sections 611.381 and 611.531.
"SM 4500-Cl G (00)"
means Method 4500-Cl G, "Chlorine (Residual)", "DPD Colorimetric
Method", only the version in the 21
st
, 22
nd
, 23
rd
,
and 24
th
editions. Referenced in Sections 611.381 and 611.531.
"SM 4500-Cl H (89)"
means Method 4500-Cl H, "Chlorine (Residual)", "Syringaldazine
(FACTS) Method", only the version in the 18
th
edition.
Referenced in Section 611.531
.381 and 611.531.
"SM 4500-Cl G (00)"
means Method 4500-Cl G, "Chlorine (Residual)", "DPD Colorimetric
Method", only the version in the 21
st
, 22
nd
, 23
rd
,
and 24
th
editions. Referenced in Sections 611.381 and 611.531.
"SM 4500-Cl H (89)"
means Method 4500-Cl H, "Chlorine (Residual)", "Syringaldazine
(FACTS) Method", only the version in the 18
th
edition.
Referenced in Section 611.531.
"SM 4500-Cl H (93)"
means Method 4500-Cl H, "Chlorine (Residual)", "Syringaldazine
(FACTS) Method", only the version in the 19
th
and 20
th
editions. Referenced in Sections 611.381 and 611.531.
"SM 4500-Cl H (00)"
means Method 4500-Cl H, "Chlorine (Residual)", "Syringaldazine
(FACTS) Method", only the version in the 21
st
, 22
nd
,
23
rd
,and 24
th
editions. Referenced in Sections 611.381
and 611.531.
"SM 4500-Cl I (89)"
means Method 4500-Cl I, "Chlorine (Residual)", "Iodometric
Electrode Method", only the version in the 18
th
edition.
Referenced in Section 611.531.
"SM 4500-Cl I (93)"
means Method 4500-Cl I, "Chlorine (Residual)", "Iodometric
Electrode Method", only the version in the 19
th
and 20
th
editions. Referenced in Sections 611.381 and 611.531.
"SM 4500-Cl I (00)"
means Method 4500-Cl I, "Chlorine (Residual)", "Iodometric
Electrode Method", only the version in the 21
st
, 22
nd
,
23
rd
, and 24
th
editions. Referenced in Sections 611.381
and 611.531.
"SM 4500-ClO
2
C
(88)" means Method 4500-ClO
2
C, "Chlorine Dioxide", "Amperometric
Method I", only the version in the 18
th
edition. Referenced in
Sections 611.381 and 611.531.
"SM 4500-ClO
2
C
(93)" means Method 4500-ClO
2
C, "Chlorine Dioxide", "Amperometric
Method I", only the version in the 19
th
and 20
th
editions. Referenced in Section 611.531.
"SM 4500-ClO
2
C
(00)" means Method 4500-ClO
2
C, "Chlorine Dioxide", "Amperometric
Method I", only the version in the 21
st
, 22
nd
, 23
rd
,
and 24
th
editions. Referenced in Section 611.531.
"SM 4500-ClO
2
D
.531.
"SM 4500-ClO
2
C
(93)" means Method 4500-ClO
2
C, "Chlorine Dioxide", "Amperometric
Method I", only the version in the 19
th
and 20
th
editions. Referenced in Section 611.531.
"SM 4500-ClO
2
C
(00)" means Method 4500-ClO
2
C, "Chlorine Dioxide", "Amperometric
Method I", only the version in the 21
st
, 22
nd
, 23
rd
,
and 24
th
editions. Referenced in Section 611.531.
"SM 4500-ClO
2
D
(88)" means Method 4500-ClO
2
D, "Chlorine Dioxide", "DPD
Method", only the version in the 18
th
edition. Referenced in
Section 611.531.
"SM 4500-ClO
2
D
(93)" means Method 4500-ClO
2
D, "Chlorine Dioxide", "DPD
Method", only the version in the 19
th
and 20
th
editions. Referenced in Sections 611.381 and 611.531.
"SM 4500-ClO
2
D
(00)" means Method 4500-ClO
2
D, "Chlorine Dioxide", "DPD
Method", only the version in the 21
st
edition. Referenced in
Section 611.381.
"SM 4500-ClO
2
E
(88)" means Method 4500-ClO
2
E, "Chlorine Dioxide", "Amperometric
Method II (Proposed)", only the version in the 18
th
edition.
Referenced in Section 611.531.
"SM 4500-ClO
2
E
(93)" means Method 4500-ClO
2
E, "Chlorine Dioxide", "Amperometric
Method II", only the version in the 19
th
and 20
th
editions. Referenced in Sections 611.381 and 611.531.
"SM 4500-ClO
2
E
(00)" means Method 4500-ClO
2
E, "Chlorine Dioxide", "Amperometric
Method II", only the version in the 21
st
, 22
nd
, 23
rd
,
and 24
th
editions. Referenced in Sections 611.381 and 611.531.
"SM 4500-CN
–
C
(90)" means Method 4500-CN
–
C, "Cyanide", "Total
Cyanide after Distillation", only the version in the 18
th
and
19
th
editions. Referenced in Section 611.611.
"SM 4500-CN
–
C
(99)" means Method 4500-CN
–
C, "Cyanide", "Total
Cyanide after Distillation", only the version in the 20
th
, 21
st
and 22
nd
editions. Referenced in Section 611.611.
"SM 4500-CN
–
C
(16)" means Method 4500-CN
–
C, "Cyanide", "Total
Cyanide after Distillation", only the version in the 23
rd
and
24
th
editions. Referenced in Section 611.611.
"SM 4500-CN
–
E
Section 611.611.
"SM 4500-CN
–
C
(99)" means Method 4500-CN
–
C, "Cyanide", "Total
Cyanide after Distillation", only the version in the 20
th
, 21
st
and 22
nd
editions. Referenced in Section 611.611.
"SM 4500-CN
–
C
(16)" means Method 4500-CN
–
C, "Cyanide", "Total
Cyanide after Distillation", only the version in the 23
rd
and
24
th
editions. Referenced in Section 611.611.
"SM 4500-CN
–
E
(90)" means Method 4500-CN
–
E, "Cyanide", "Colorimetric
Method", only the version in the 18
th
and 19
th
editions. Referenced in Section 611.611.
"SM 4500-CN
–
E
(97)" means Method 4500-CN
–
E, "Cyanide", "Colorimetric
Method", only the version in the 20
th
edition. Referenced in
Section 611.611.
"SM 4500-CN
–
E
(99)" means Method 4500-CN
–
E, "Cyanide", "Colorimetric
Method", only the version in the 21
st
, 22
nd
, and 23
rd
editions. Referenced in Section 611.611.
"SM 4500-CN
–
E
(16)" means Method 4500-CN
–
E, "Cyanide", "Colorimetric
Method", only the version in the 23
rd
and 24
th
editions. Referenced in Section 611.611.
"SM 4500-CN
–
F
(90)" means Method 4500-CN
–
F, "Cyanide", "Cyanide-Selective
Electrode Method", only the version in the 18
th
and 19
th
editions. Referenced in Section 611.611.
"SM 4500-CN
–
F
(97)" means Method 4500-CN
–
F, "Cyanide", "Cyanide-Selective
Electrode Method", only the version in the 20
th
edition.
Referenced in Section 611.611.
"SM 4500-CN
–
F
(99)" means Method 4500-CN
–
F, "Cyanide", "Cyanide-Selective
Electrode Method", only the version in the 21
st
and 22
nd
editions. Referenced in Section 611.611.
"SM 4500-CN
–
F
(16)" means Method 4500-CN
–
F, "Cyanide", "Cyanide-Ion
Selective Electrode Method", only the version in the 23
rd
and
24
th
edition. Referenced in Section 611.611.
"SM 4500-CN
–
G
(90)" means Method 4500-CN
–
G, "Cyanide", "Cyanides
Amenable to Chlorination after Distillation", only the version in the 18
th
and 19
th
editions. Referenced in Section 611.611.
"SM 4500-CN
–
G
"SM 4500-CN
–
F
(16)" means Method 4500-CN
–
F, "Cyanide", "Cyanide-Ion
Selective Electrode Method", only the version in the 23
rd
and
24
th
edition. Referenced in Section 611.611.
"SM 4500-CN
–
G
(90)" means Method 4500-CN
–
G, "Cyanide", "Cyanides
Amenable to Chlorination after Distillation", only the version in the 18
th
and 19
th
editions. Referenced in Section 611.611.
"SM 4500-CN
–
G
(97)" means Method 4500-CN
–
G, "Cyanide", "Cyanides
Amenable to Chlorination after Distillation", only the version in the 20
th
edition. Referenced in Section 611.611.
"SM 4500-CN
–
G
(99)" means Method 4500-CN
–
G, "Cyanide", "Cyanides
Amenable to Chlorination after Distillation", only the version in the 21
st
and 22
nd
editions. Referenced in Section 611.611.
"SM 4500-CN
–
G
(16)" means Method 4500-CN
–
G, "Cyanide", "Cyanides
Amenable to Chlorination after Distillation", only the version in the 23
rd
and 24
th
edition. Referenced in Section 611.611.
"SM 4500-F
–
B (88)"
means Method 4500-F
–
B, "Fluoride", "Preliminary
Distillation Step", only the version in the 18
th
edition.
Referenced in Section 611.611.
"SM 4500-F
–
B (94)"
means Method 4500-F
–
B, "Fluoride", "Preliminary
Distillation Step", only the version in the 19
th
edition.
Referenced in Section 611.611.
"SM 4500-F
–
B (97)"
means Method 4500-F
–
B, "Fluoride", "Preliminary
Distillation Step", only the version in the 20
th
, 21
st
,
22
nd
, 23
rd
, and 24
th
editions. Referenced in
Section 611.611.
"SM 4500-F
–
C (88)"
means Method 4500-F
–
C, "Fluoride", "Ion-Selective
Electrode Method", only the version in the 18
th
edition.
Referenced in Section 611.611.
"SM 4500-F
–
C (94)"
means Method 4500-F
–
C, "Fluoride", "Ion-Selective
Electrode Method", only the version in the 19
th
edition.
Referenced in Section 611.611.
"SM 4500-F
–
C (97)"
means Method 4500-F
–
C, "Fluoride", "Ion-Selective
Electrode Method", only the version in the 20
th
, 21
st
,
22
nd
, 23
rd
, and 24
th
editions. Referenced in
Section 611.611
Referenced in Section 611.611.
"SM 4500-F
–
C (94)"
means Method 4500-F
–
C, "Fluoride", "Ion-Selective
Electrode Method", only the version in the 19
th
edition.
Referenced in Section 611.611.
"SM 4500-F
–
C (97)"
means Method 4500-F
–
C, "Fluoride", "Ion-Selective
Electrode Method", only the version in the 20
th
, 21
st
,
22
nd
, 23
rd
, and 24
th
editions. Referenced in
Section 611.611.
"SM 4500-F
–
D (88)"
means Method 4500-F
–
D, "Fluoride", "SPADNS Method",
only the version in the 18
th
edition. Referenced in Section
611.611.
"SM 4500-F
–
D (94)"
means Method 4500-F
–
D, "Fluoride", "SPADNS Method",
only the version in the 19
th
edition. Referenced in Section
611.611.
"SM 4500-F
–
D (97)"
means Method 4500-F
–
D, "Fluoride", "SPADNS Method",
only the version in the 20
th
, 21
st
, 22
nd
, 23
rd
,
and 24
th
editions. Referenced in Section 611.611.
"SM 4500-F
–
E (88)"
means Method 4500-F
–
E, "Fluoride", "Complexone
Method", only the version in the 18
th
edition. Referenced in
Section 611.611.
"SM 4500-F
–
E (94)"
means Method 4500-F
–
E, "Fluoride", "Complexone
Method", only the version in the 19
th
edition. Referenced in
Section 611.611.
"SM 4500-F
–
E (97)"
means Method 4500-F
–
E, "Fluoride", "Complexone
Method", only the version in the 20
th
, 21
st
, 22
nd
,
23
rd
, and 24
th
editions. Referenced in Section 611.611.
"SM 4500-H
+
B (90)"
means Method 4500-H
+
B, "pH Value", "Electrometric
Method", only the version in the 18
th
and 19
th
editions. Referenced in Section 611.611.
"SM 4500-H
+
B (96)"
means Method 4500-H
+
B, "pH Value", "Electrometric
Method", only the version in the 20
th
edition. Referenced in
Section 611.611.
"SM 4500-H
+
B (00)"
means Method 4500-H
+
B, "pH Value", "Electrometric
Method", only the version in the 21
st
, 22
nd
, and 23
rd
editions. Referenced in Section 611.611.
"SM 4500-H
+
B (21)"
means Method 4500-H
+
B, "pH Value", "Electrometric
Method", only the version in the 24
th
edition. Referenced in
Section 611.611
ly the version in the 20
th
edition. Referenced in
Section 611.611.
"SM 4500-H
+
B (00)"
means Method 4500-H
+
B, "pH Value", "Electrometric
Method", only the version in the 21
st
, 22
nd
, and 23
rd
editions. Referenced in Section 611.611.
"SM 4500-H
+
B (21)"
means Method 4500-H
+
B, "pH Value", "Electrometric
Method", only the version in the 24
th
edition. Referenced in
Section 611.611.
"SM 4500-NO
3
–
D (88)" means Method 4500-NO
3
–
D, "Nitrogen
(Nitrate)", "Nitrate Electrode Method", only the version in the
18th edition. Referenced in Section 611.611.
"SM 4500-NO
3
–
D (93)" means Method 4500-NO
3
–
D, "Nitrogen
(Nitrate)", "Nitrate Electrode Method", only the version in the
19
th
edition. Referenced in Section 611.611.
"SM 4500-NO
3
–
D (97)" means Method 4500-NO
3
–
D, "Nitrogen (Nitrate)",
"Nitrate Electrode Method", only the version in the 20
th
edition. Referenced in Section 611.611.
"SM 4500-NO
3
–
D (00)" means Method 4500-NO
3
–
D, "Nitrogen
(Nitrate)", "Nitrate Electrode Method", only the version in the
21
st
and 22
nd
editions. Referenced in Section 611.611.
"SM 4500-NO
3
–
D (16)" means Method 4500-NO
3
–
D, "Nitrogen
(Nitrate)", "Nitrate Electrode Method", only the version in the
23
rd
and 24
th
editions. Referenced in Section 611.611.
"SM 4500-NO
3
–
E (88)" means Method 4500-NO
3
–
E, "Nitrogen
(Nitrate)", "Cadmium Reduction Method", only the version in the
18
th
edition. Referenced in Section 611.611.
"SM 4500-NO
3
–
E (93)" means Method 4500-NO
3
–
E, "Nitrogen
(Nitrate)", "Cadmium Reduction Method", only the version in the
19
th
edition. Referenced in Section 611.611.
"SM 4500-NO
3
–
E (97)" means Method 4500-NO
3
–
E, "Nitrogen
(Nitrate)", "Cadmium Reduction Method", only the version in the
20
th
edition. Referenced in Section 611.611.
"SM 4500-NO
3
–
E (00)" means Method 4500-NO
3
–
E, "Nitrogen
(Nitrate)", "Cadmium Reduction Method", only the version in the
21
st
and 22
nd
editions. Referenced in Section 611.611
edition. Referenced in Section 611.611.
"SM 4500-NO
3
–
E (97)" means Method 4500-NO
3
–
E, "Nitrogen
(Nitrate)", "Cadmium Reduction Method", only the version in the
20
th
edition. Referenced in Section 611.611.
"SM 4500-NO
3
–
E (00)" means Method 4500-NO
3
–
E, "Nitrogen
(Nitrate)", "Cadmium Reduction Method", only the version in the
21
st
and 22
nd
editions. Referenced in Section 611.611.
"SM 4500-NO
3
–
E (16)" means Method 4500-NO
3
–
E, "Nitrogen
(Nitrate)", "Cadmium Reduction Method", only the version in the
23
rd
and 24
th
editions. Referenced in Section 611.611.
"SM 4500-NO
3
–
F (88)" means Method 4500-NO
3
–
F, "Nitrogen
(Nitrate)", "Automated Cadmium Reduction Method", only the
version in the 18
th
edition. Referenced in Section 611.611.
"SM 4500-NO
3
–
F (93)" means Method 4500-NO
3
–
F, "Nitrogen
(Nitrate)", "Automated Cadmium Reduction Method", only the
version in the 19
th
edition. Referenced in Section 611.611.
"SM 4500-NO
3
–
F (97)" means Method 4500-NO
3
–
F, "Nitrogen (Nitrate)",
"Automated Cadmium Reduction Method", only the version in the 20
th
edition. Referenced in Section 611.611.
"SM 4500-NO
3
–
F (00)" means Method 4500-NO
3
–
F, "Nitrogen
(Nitrate)", "Automated Cadmium Reduction Method", only the
version in the 21
st
and 22
nd
editions. Referenced in
Section 611.611.
"SM 4500-NO
3
–
F (16)" means Method 4500-NO
3
–
F, "Nitrogen
(Nitrate)", "Automated Cadmium Reduction Method", only the
version in the 23
rd
and 24
th
editions. Referenced in
Section 611.611.
"SM 4500-NO
2
–
B (88)" means Method 4500-NO
2
–
B, "Nitrogen
(Nitrite)", "Colorimetric Method", only the version in the 18
th
edition. Referenced in Section 611.611.
"SM 4500-NO
2
–
B (93)" means Method 4500-NO
2
–
B, "Nitrogen
(Nitrite)", "Colorimetric Method", only the version in the 19
th
and 20
th
editions. Referenced in Section 611.611
and 24
th
editions. Referenced in
Section 611.611.
"SM 4500-NO
2
–
B (88)" means Method 4500-NO
2
–
B, "Nitrogen
(Nitrite)", "Colorimetric Method", only the version in the 18
th
edition. Referenced in Section 611.611.
"SM 4500-NO
2
–
B (93)" means Method 4500-NO
2
–
B, "Nitrogen
(Nitrite)", "Colorimetric Method", only the version in the 19
th
and 20
th
editions. Referenced in Section 611.611.
"SM 4500-NO
2
–
B (00)" means Method 4500-NO
2
–
B, "Nitrogen
(Nitrite)", "Colorimetric Method", only the version in the 21
st
,
22
nd
, 23
rd
, and 24
th
editions. Referenced in
Section 611.611.
"SM 4500-O
3
B (88)"
means Method 4500-O
3
B, "Ozone (Residual) (Proposed)", "Indigo
Colorimetric Method", only the version in the 18
th
edition.
Referenced in Section 611.531.
"SM 4500-O
3
B (93)"
means Method 4500-O
3
B, "Ozone (Residual)", "Indigo
Colorimetric Method", only the version in the 19
th
edition.
Referenced in Section 611.531.
"SM 4500-O3 B (97)"
means Method 4500-O
3
B, "Ozone (Residual)", "Indigo
Colorimetric Method", only the version in the 20
th
, 21
st
,
22
nd
, 23
rd
, and 24
th
editions. Referenced in
Section 611.531.
"SM 4500-P E (88)" means
Method 4500-P E, "Phosphorus", "Ascorbic Acid Method", only
the version in the 18
th
edition. Referenced in Section 611.611.
"SM 4500-P E (93)" means
Method 4500-P E, "Phosphorus", "Ascorbic Acid Method", only
the version in the 19
th
edition. Referenced in Section 611.611.
"SM 4500-P E (97)" means
Method 4500-P E, "Phosphorus", "Ascorbic Acid Method", only
the version in the 20
th
edition. Referenced in Section 611.611.
"SM 4500-P E (99)" means
Method 4500-P E, "Phosphorus", "Ascorbic Acid Method", only
the version in the 21
st
and 22
nd
editions. Referenced in
Section 611.611.
"SM 4500-P E (05)" means
Method 4500-P E, "Phosphorus", "Ascorbic Acid Method", only
the version in the 23
rd
and 24
th
editions. Referenced in
Section 611.611
only
the version in the 20
th
edition. Referenced in Section 611.611.
"SM 4500-P E (99)" means
Method 4500-P E, "Phosphorus", "Ascorbic Acid Method", only
the version in the 21
st
and 22
nd
editions. Referenced in
Section 611.611.
"SM 4500-P E (05)" means
Method 4500-P E, "Phosphorus", "Ascorbic Acid Method", only
the version in the 23
rd
and 24
th
editions. Referenced in
Section 611.611.
"SM 4500-P F (88)" means
Method 4500-P F, "Phosphorus", "Automated Ascorbic Acid
Reduction Method", only the version in the 18
th
edition.
Referenced in Section 611.611.
"SM 4500-P F (93)" means
Method 4500-P F, "Phosphorus", "Automated Ascorbic Acid
Reduction Method", only the version in the 19
th
edition.
Referenced in Section 611.611.
"SM 4500-P F (97)" means
Method 4500-P F, "Phosphorus", "Automated Ascorbic Acid
Reduction Method", only the version in the 20
th
edition.
Referenced in Section 611.611.
"SM 4500-P F (99)" means
Method 4500-P F, "Phosphorus", "Automated Ascorbic Acid
Reduction Method", only the version in the 21
st
and 22
nd
editions. Referenced in Section 611.611.
"SM 4500-P F (05)" means
Method 4500-P F, "Phosphorus", "Automated Ascorbic Acid
Reduction Method", only the version in the 23
rd
and 24
th
editions. Referenced in Section 611.611.
"SM 4500-Si D (88)"
means Method 4500-Si D, "Silica", "Molybdosilicate Method",
only the version in the 18
th
edition. Referenced in Section
611.611.
"SM 4500-Si D (93)"
means Method 4500-Si D, "Silica", "Molybdosilicate Method",
only the version in the 19
th
edition. Referenced in Section
611.611.
"SM 4500-Si E (88)"
means Method 4500-Si E, "Silica", "Molybdosilicate Method",
only the version in the 18
th
edition. Referenced in Section
611.611.
"SM 4500-Si E (93)"
means Method 4500-Si E, "Silica", "Molybdosilicate Method",
only the version in the 19
th
edition. Referenced in Section
611.611.
"SM 4500-Si F (88)"
means Method 4500-Si F, "Silica", "Molybdosilicate Method",
only the version in the 18
th
edition
Method 4500-Si E, "Silica", "Molybdosilicate Method",
only the version in the 18
th
edition. Referenced in Section
611.611.
"SM 4500-Si E (93)"
means Method 4500-Si E, "Silica", "Molybdosilicate Method",
only the version in the 19
th
edition. Referenced in Section
611.611.
"SM 4500-Si F (88)"
means Method 4500-Si F, "Silica", "Molybdosilicate Method",
only the version in the 18
th
edition. Referenced in Section
611.611.
"SM 4500-Si F (93)"
means Method 4500-Si F, "Silica", "Molybdosilicate Method",
only the version in the 19
th
edition. Referenced in Section
611.611.
"SM 4500-SiO
2
C
(97)" means Method 4500-SiO
2
C, "Silica", "Molybdosilicate
Method", only the version in the 20
th
, 21
st
, 22
nd
,
23
rd
,and 24
th
editions. Referenced in Section 611.611.
"SM 4500-SiO
2
D
(97)" means Method 4500-SiO
2
D, "Silica", "Heteropoly
Blue Method", only the version in the 20
th
, 21
st
, 22
nd
,
23
rd
, and 24
th
editions. Referenced in Section 611.611.
"SM 4500-SiO
2
E
(97)" means Method 4500-SiO
2
E, "Silica", "Automated
Method for Molybdate-Reactive Silica", only the version in the 20
th
,
21
st
, 22
nd
, 23
rd
, and 24
th
editions.
Referenced in Section 611.611.
"SM 5310 B (92)" means
Method 5310 B, "Total Organic Carbon (TOC)", "Combustion-Infrared
Method", only the version in the supplement to the 19
th
edition. Referenced in Section 611.381.
"SM 5310 B (96)" means
Method 5310 B, "Total Organic Carbon (TOC)", "High-Temperature
Combustion Method", only the version in the 20
th
edition.
Referenced in Section 611.381.
"SM 5310 B (00)" means
Method 5310 B, "Total Organic Carbon (TOC)", "High-Temperature
Combustion Method", only the version in the 21
st
and 22
nd
editions. Referenced in Section 611.381.
"SM 5310 B (14)" means
Method 5310 B, "Total Organic Carbon (TOC)", "High-Temperature
Combustion Method", only the version in the 23
rd
edition.
Referenced in Section 611.381
Referenced in Section 611.381.
"SM 5310 B (00)" means
Method 5310 B, "Total Organic Carbon (TOC)", "High-Temperature
Combustion Method", only the version in the 21
st
and 22
nd
editions. Referenced in Section 611.381.
"SM 5310 B (14)" means
Method 5310 B, "Total Organic Carbon (TOC)", "High-Temperature
Combustion Method", only the version in the 23
rd
edition.
Referenced in Section 611.381.
"SM 5310 B (22)" means
Method 5310 B, "Total Organic Carbon (TOC)", "High-Temperature
Combustion Method", only the version in the 24
th
edition.
Referenced in Section 611.381.
"SM 5310 C (92)" means
Method 5310 C, "Total Organic Carbon (TOC)", "Persulfate-Ultraviolet
Oxidation Method", only the version in the supplement to the 19
th
edition. Referenced in Section 611.381.
"SM 5310 C (96)" means
Method 5310 C, "Total Organic Carbon (TOC)", "Persulfate-Ultraviolet
or Heated-Persulfate Oxidation Method", only the version in the 20
th
edition. Referenced in Section 611.381.
"SM 5310 C (00)" means
Method 5310 C, "Total Organic Carbon (TOC)", "Persulfate-Ultraviolet
or Heated-Persulfate Oxidation Method", only the version in the 21
st
and 22
nd
editions. Referenced in Section 611.381.
"SM 5310 C (14)" means
Method 5310 C, "Total Organic Carbon (TOC)", "Persulfate-Ultraviolet
or Heated-Persulfate Oxidation Method", only the version in the 23
rd
and 24
th
editions. Referenced in Section 611.381.
"SM 5310 D (92)" means
Method 5310 D, "Total Organic Carbon (TOC)", "Wet-Oxidation
Method", only the version in the supplement to the 19
th
edition. Referenced in Section 611.381.
"SM 5310 D (96)" means
Method 5310 D, "Total Organic Carbon (TOC)", "Wet-Oxidation
Method", only the version in the 20
th
edition. Referenced in
Section 611.381.
"SM 5310 D (00)" means
Method 5310 D, "Total Organic Carbon (TOC)", "Wet-Oxidation
Method", only the version in the 21
st
and 22
nd
editions
", only the version in the supplement to the 19
th
edition. Referenced in Section 611.381.
"SM 5310 D (96)" means
Method 5310 D, "Total Organic Carbon (TOC)", "Wet-Oxidation
Method", only the version in the 20
th
edition. Referenced in
Section 611.381.
"SM 5310 D (00)" means
Method 5310 D, "Total Organic Carbon (TOC)", "Wet-Oxidation
Method", only the version in the 21
st
and 22
nd
editions. Referenced in Section 611.381."
"SM 5910 B (94)" means
Method 5910 B, "UV-Absorbing Organic Constituents", "Ultraviolet
Absorption Method", only the version in the 19
th
and 20
th
editions. Referenced in Section 611.381.
"SM 5910 B (00)" means
Method 5910 B, "UV-Absorbing Organic Constituents", "Ultraviolet
Absorption Method", only the version in the 21
st
edition.
Referenced in Section 611.381.
"SM 5910 B (11)" means
Method 5910 B, "UV-Absorbing Organic Constituents", "Ultraviolet
Absorption Method", only the version in the 22
nd
edition.
Referenced in Section 611.381.
"SM 5910 B (13)" means
Method 5910 B, "UV-Absorbing Organic Constituents", "Ultraviolet
Absorption Method", only the version in the 23
rd
and 24
th
editions. Referenced in Section 611.381.
"SM 6251 B (94)" means
Method 6251 B, "Disinfection By-Products: Haloacetic Acids and
Trichlorophenol", "Micro Liquid-Liquid Extraction Gas Chromatographic
Method", only the version in the 19
th
, 20
th
, and 21
st
editions. Referenced in Section 611.381.
"SM 6251 B (07)" means
Method 6251 B, "Disinfection By-Products: Haloacetic Acids and
Trichlorophenol", "Micro Liquid-Liquid Extraction Gas Chromatographic
Method", only the version in the 22
nd
, 23
rd
, and 24
th
editions. Referenced in Section 611.381.
"SM 6610 (92)" means
Method 6610, "Carbamate Pesticides (Proposed)", only the version in
the supplement to the 18
th
edition and the 19
th
edition.
Referenced in Section 611.645.
"SM 6610 (96)" means
Method 6610, "Carbamate Pesticides", only the version in the 20
th
edition. Referenced in Section 611.645
y the version in the 22
nd
, 23
rd
, and 24
th
editions. Referenced in Section 611.381.
"SM 6610 (92)" means
Method 6610, "Carbamate Pesticides (Proposed)", only the version in
the supplement to the 18
th
edition and the 19
th
edition.
Referenced in Section 611.645.
"SM 6610 (96)" means
Method 6610, "Carbamate Pesticides", only the version in the 20
th
edition. Referenced in Section 611.645.
"SM 6610 B (99)" means
Method 6610, "Carbamate Pesticides
",
"High-Performance Liquid Chromatographic Method
",
only the version in the 21
st
edition. Referenced in Section
611.645.
"SM 6610 B (04)" means
Method 6610, "Carbamate Pesticides", "High-Performance Liquid
Chromatographic Method", only the version in 22
nd
, 23
rd
,
and 24
th
editions. Referenced in Section 611.645.
"SM 6640 B (01)" means
Method 6640 B, "Acidic Herbicide Compounds", "Micro
Liquid-Liquid Extraction Gas Chromatographic Method", only the version in
21
st
edition. Referenced in Section 611.645.
"SM 6640 B (06)" means
Method 6640 B, "Acidic Herbicide Compounds", "Micro
Liquid-Liquid Extraction Gas Chromatographic Method", only the version in
22
nd
, 23
rd
, and 24
th
editions. Referenced in
Section 611.645.
"SM 6651 B (91)" means
Method 6651 B, "Glyphosate Herbicide (Proposed)
",
"Liquid Chromatographic Post-Column Fluorescence
Method
", only the version in 18
th
edition, or "Glyphosate
Herbicide", "Liquid Chromatographic Post-Column Fluorescence Method",
in 19
th
edition. Referenced in Section 611.645.
"SM 6651 B (96)" means
Method 6651 B, "Glyphosate Herbicide", "Liquid Chromatographic
Post-Column Fluorescence Method", only the version in 20
th
edition. Referenced in Section 611.645.
"SM 6651 B (00)" means
Method 6651 B, "Glyphosate Herbicide", "Liquid Chromatographic
Post-Column Fluorescence Method", only the version in 21
st
edition. Referenced in Section 611.645
ced in Section 611.645.
"SM 6651 B (96)" means
Method 6651 B, "Glyphosate Herbicide", "Liquid Chromatographic
Post-Column Fluorescence Method", only the version in 20
th
edition. Referenced in Section 611.645.
"SM 6651 B (00)" means
Method 6651 B, "Glyphosate Herbicide", "Liquid Chromatographic
Post-Column Fluorescence Method", only the version in 21
st
edition. Referenced in Section 611.645.
"SM 6651 B (05)" means
Method 6651 B, "Glyphosate Herbicide", "Liquid Chromatographic
Post-Column Fluorescence Method", only the version in 22
nd
, 23
rd
,
and 24
th
editions. Referenced in Section 611.645.
"SM 7110 B (85)" means
Method 7110 B, "Gross Alpha and Beta Radioactivity (Total, Suspended, and
Dissolved)", "Counting Method", only the version in 17
th
edition. Referenced in Section 611.720.
"SM 7110 B (91)" means
Method 7110 B, "Gross Alpha and Beta Radioactivity (Total, Suspended, and
Dissolved)", "Evaporation Method for Gross Alpha-Beta", only the
version in 18
th
and 19
th
editions. Referenced in Section
611.720.
"SM 7110 B (96)" means
Method 7110 B, "Gross Alpha and Beta Radioactivity (Total, Suspended, and
Dissolved)", "Evaporation Method for Gross Alpha-Beta", only the
version in 20
th
edition. Referenced in Section 611.720.
"SM 7110 B (00)" means
Method 7110 B, "Gross Alpha and Beta Radioactivity (Total, Suspended, and
Dissolved)", "Evaporation Method for Gross Alpha-Beta", only the
version in 21
st
, 22
nd
, and 23
rd
editions.
Referenced in Section 611.720.
"SM 7110 B (21)" means
Method 7110 B, "Gross Alpha and Beta Radioactivity (Total, Suspended, and
Dissolved)", "Evaporation Method for Gross Alpha-Beta", only the
version in the 24
th
edition. Referenced in Section 611.720.
"SM 7110 C (91)" means
Method 7110 C, "Gross Alpha and Beta Radioactivity (Total, Suspended, and
Dissolved)", "Coprecipitation Method for Gross Alpha Radioactivity in
Drinking Water (Proposed)", only the version in 18
th
and 19
th
editions. Referenced in Section 611.720
ssolved)", "Evaporation Method for Gross Alpha-Beta", only the
version in the 24
th
edition. Referenced in Section 611.720.
"SM 7110 C (91)" means
Method 7110 C, "Gross Alpha and Beta Radioactivity (Total, Suspended, and
Dissolved)", "Coprecipitation Method for Gross Alpha Radioactivity in
Drinking Water (Proposed)", only the version in 18
th
and 19
th
editions. Referenced in Section 611.720.
"SM 7110 C (96)" means
Method 7110 C, "Gross Alpha and Beta Radioactivity (Total, Suspended, and
Dissolved)", "Coprecipitation Method for Gross Alpha Radioactivity in
Drinking Water", only the version in 20
th
edition. Referenced
in Section 611.720.
"SM 7110 C (00)" means
Method 7110 C, "Gross Alpha and Beta Radioactivity (Total, Suspended, and
Dissolved)", "Coprecipitation Method for Gross Alpha Radioactivity in
Drinking Water", only the version in 21
st
, 22
nd
, and
23
rd
editions. Referenced in Section 611.720.
"SM 7110 C (21)" means
Method 7110 C, "Gross Alpha and Beta Radioactivity (Total, Suspended, and
Dissolved)", "Evaporation Method for Gross Alpha-Beta", only the
version in the 24
th
edition. Referenced in Section 611.720.
"SM 7110 D (17)" means
Method 7110 D, "Gross Alpha and Beta Radioactivity (Total, Suspended, and
Dissolved)", "Liquid Scintillation Spectroscopic Method for Gross
Alpha-Beta Radioactivity in Drinking Water", only the version from
Standard Methods Online as Method 7110 D-17. Referenced in Section 611.720.
"SM 7110 D (21)" means
Method 7110 D, "Gross Alpha and Beta Radioactivity (Total, Suspended, and
Dissolved)", "Liquid Scintillation Spectroscopic Method for Gross Alpha-Beta
Radioactivity in Drinking Water", only the version in the 24
th
edition. Referenced in Section 611.720.
"SM 7120 (94)" means
Method 7120, "Gamma-Emitting Radionuclides", only the version in the
19
th
edition. Referenced in Section 611.720.
"SM 7120 (97)" means
Method 7120, "Gamma-Emitting Radionuclides", only the version in the
20
th
, 21
st
, 22
nd
, and 23
rd
editions
for Gross Alpha-Beta
Radioactivity in Drinking Water", only the version in the 24
th
edition. Referenced in Section 611.720.
"SM 7120 (94)" means
Method 7120, "Gamma-Emitting Radionuclides", only the version in the
19
th
edition. Referenced in Section 611.720.
"SM 7120 (97)" means
Method 7120, "Gamma-Emitting Radionuclides", only the version in the
20
th
, 21
st
, 22
nd
, and 23
rd
editions. Referenced in Section 611.720.
"SM 7120 (21)" means
Method 7120, "Gamma-Emitting Radionuclides", only the version in the 24
th
edition. Referenced in Section 611.720.
"SM 7500-Cs B (88)"
means Method 7500-Cs B, "Radioactive Cesium", "Precipitation
Method", only the version in the 17
th
and 18
th
editions. Referenced in Section 611.720.
"SM 7500-Cs B (93)"
means Method 7500-Cs B, "Radioactive Cesium", "Precipitation
Method", only the version in the 19
th
and 20
th
editions. Referenced in Section 611.720.
"SM 7500-Cs B (00)"
means Method 7500-Cs B, "Radioactive Cesium", "Precipitation
Method", only the version in the 21
st
, 22
nd
, 23
rd
,
and 24
th
editions. Referenced in Section 611.720.
"SM 7500-I B (88)" means
Method 7500-I B, "Radioactive Iodine", "Precipitation Method",
only the version in the 17
th
and 18
th
editions.
Referenced in Section 611.720.
"SM 7500-I B (93)" means
Method 7500-I B, "Radioactive Iodine", "Precipitation Method",
only the version in the 19
th
and 20
th
editions.
Referenced in Section 611.720.
"SM 7500-I B (00)" means
Method 7500-I B, "Radioactive Iodine", "Precipitation Method",
only the version in the 21
st
, 22
nd
, 23
rd
, and
24
th
editions. Referenced in Section 611.720.
"SM 7500-I C (88)" means
Method 7500-I C, "Radioactive Iodine", "Ion-Exchange Method",
only the version in the 17
th
and 18
th
editions.
Referenced in Section 611.720.
"SM 7500-I C (93)" means
Method 7500-I C, "Radioactive Iodine", "Ion-Exchange Method",
only the version in the 19
th
and 20
th
editions.
Referenced in Section 611.720
rd
, and
24
th
editions. Referenced in Section 611.720.
"SM 7500-I C (88)" means
Method 7500-I C, "Radioactive Iodine", "Ion-Exchange Method",
only the version in the 17
th
and 18
th
editions.
Referenced in Section 611.720.
"SM 7500-I C (93)" means
Method 7500-I C, "Radioactive Iodine", "Ion-Exchange Method",
only the version in the 19
th
and 20
th
editions.
Referenced in Section 611.720.
"SM 7500-I C (00)" means
Method 7500-I C, "Radioactive Iodine", "Ion-Exchange Method",
only the version in the 21
st
, 22
nd
, 23
rd
, and
24
th
editions. Referenced in Section 611.720.
"SM 7500-I D (88)" means
Method 7500-I D, "Radioactive Iodine", "Distillation Method",
only the version in the 17
th
and 18
th
editions.
Referenced in Section 611.720.
"SM 7500-I D (93)" means
Method 7500-I D, "Radioactive Iodine", "Distillation Method",
only the version in the 19
th
and 20
th
editions.
Referenced in Section 611.720.
"SM 7500-I D (00)" means
Method 7500-I D, "Radioactive Iodine", "Distillation Method",
only the version in the 21
st
, 22
nd
, 23
rd
, and
24
th
editions. Referenced in Section 611.720.
"SM 7500-Ra B (88)"
means Method 7500-Ra B, "Radium", "Precipitation Method",
only the version in the 17
th
and 18
th
editions.
Referenced in Section 611.720.
"SM 7500-Ra B (93)"
means Method 7500-Ra B, "Radium", "Precipitation Method",
only the version in the 19
th
and 20
th
editions.
Referenced in Section 611.720.
"SM 7500-Ra B (01)"
means Method 7500-Ra B, "Radium", "Precipitation Method",
only the version in the 21
st
, 22
nd
, 23
rd
, and
24
th
editions. Referenced in Section 611.720.
"SM 7500-Ra C (88)" means
Method 7500-Ra C, "Radium", "Emanation Method", only the
version in the 17
th
and 18
th
editions. Referenced in
Section 611.720.
"SM 7500-Ra C (93)"
means Method 7500-Ra C, "Radium", "Emanation Method", only
the version in the 19
th
and 20
th
editions. Referenced in
Section 611.720
in the 21
st
, 22
nd
, 23
rd
, and
24
th
editions. Referenced in Section 611.720.
"SM 7500-Ra C (88)" means
Method 7500-Ra C, "Radium", "Emanation Method", only the
version in the 17
th
and 18
th
editions. Referenced in
Section 611.720.
"SM 7500-Ra C (93)"
means Method 7500-Ra C, "Radium", "Emanation Method", only
the version in the 19
th
and 20
th
editions. Referenced in
Section 611.720.
"SM 7500-Ra C (01)"
means Method 7500-Ra C, "Radium", "Emanation Method", only
the version in the 21
st
, 22
nd
, 23
rd
, and 24
th
editions. Referenced in Section 611.720.
"SM 7500-Ra D (88)"
means Method 7500-Ra D, "Radium", "Sequential Precipitation
Method", only the version in the 17
th
and 18
th
editions. Referenced in Section 611.720.
"SM 7500-Ra D (93)"
means Method 7500-Ra D, "Radium", "Sequential Precipitation
Method", only the version in the 19
th
and 20
th
editions. Referenced in Section 611.720.
"SM 7500-Ra D (01)"
means Method 7500-Ra D, "Radium", "Sequential Precipitation
Method", only the version in the 21
st
, 22
nd
, 23
rd
,
and 24
th
editions. Referenced in Section 611.720.
"SM 7500-Ra E (07)"
means Method 7500-Ra E, "Radium", "Gamma Spectrometry Method",
only the version in the 22
nd
, 23
rd
and 24
th
editions. Referenced in Section 611.720.
"SM 7500-Sr B (88)"
means Method 7500-Sr B, "Total Radioactive Strontium and Strontium 90",
"Precipitation Method", only the version in the 17
th
and
18
th
editions. Referenced in Section 611.720.
"SM 7500-Sr B (93)"
means Method 7500-Sr B, "Total Radioactive Strontium and Strontium 90",
"Precipitation Method", only the version in the 19
th
and
20
th
editions. Referenced in Section 611.720.
"SM 7500-Sr B (01)"
means Method 7500-Sr B, "Total Radioactive Strontium and Strontium 90",
"Precipitation Method", only the version in the 21
st
, 22
nd
,
23
rd
, and 24
th
editions. Referenced in Section 611.720
"
means Method 7500-Sr B, "Total Radioactive Strontium and Strontium 90",
"Precipitation Method", only the version in the 19
th
and
20
th
editions. Referenced in Section 611.720.
"SM 7500-Sr B (01)"
means Method 7500-Sr B, "Total Radioactive Strontium and Strontium 90",
"Precipitation Method", only the version in the 21
st
, 22
nd
,
23
rd
, and 24
th
editions. Referenced in Section 611.720.
"SM 7500-
3
H B (88)"
means Method 7500-
3
H B, "Tritium", "Liquid
Scintillation Spectrometric Method", only the version in the 17
th
and 18
th
editions. Referenced in Section 611.720.
"SM 7500-
3
H
B (93)" means Method 7500-
3
H
B, "Tritium", "Liquid Scintillation Spectrometric Method",
only the version in the 19
th
and 20
th
editions.
Referenced in Section 611.720.
"SM 7500-
3
H B (00)"
means Method 7500-
3
H B, "Tritium", "Liquid
Scintillation Spectrometric Method", only the version in the 21
st
,
22
nd
, and 23
rd
editions. Referenced in Section 611.720.
"SM 7500-
3
H B (22)"
means Method 7500-
3
H B, "Tritium", "Liquid
Scintillation Spectrometric Method", only the version in the 24
th
edition. Referenced in Section 611.720.
"SM 7500-U B (88)" means
Method 7500-U B, "Uranium", "Radiochemical Method (Proposed)",
only the version in the 17
th
edition. Referenced in Section
611.720.
"SM 7500-U B (91)" means
only Method 7500-U B, "Uranium", "Radiochemical Method
(Proposed)", the version in the 18
th
edition, and "Uranium",
"Radiochemical Method", the version in the 19
th
edition.
Referenced in Section 611.720.
"SM 7500-U B (96)" means
Method 7500-U B, "Uranium", "Radiochemical Method", only
the version in the 20
th
edition. Referenced in Section 611.720.
"SM 7500-U B (00)" means
Method 7500-U B, "Uranium", "Radiochemical Method", only
the version in the 21
st
, 22
nd
, 23
rd
, and 24
th
editions. Referenced in Section 611.720.
"SM 7500-U C (88)" means
Method 7500-U C, "Uranium",
"Fluorometric
Method
(Proposed)", only the version in the 17
th
edition. Referenced
in Section 611.720
version in the 20
th
edition. Referenced in Section 611.720.
"SM 7500-U B (00)" means
Method 7500-U B, "Uranium", "Radiochemical Method", only
the version in the 21
st
, 22
nd
, 23
rd
, and 24
th
editions. Referenced in Section 611.720.
"SM 7500-U C (88)" means
Method 7500-U C, "Uranium",
"Fluorometric
Method
(Proposed)", only the version in the 17
th
edition. Referenced
in Section 611.720.
"SM 7500-U C (91)" means
Method 7500-U C, "Uranium", "Isotopic Method (Proposed)
", only the version in the 18
th
and 19
th
editions. R
eferenced in Section 611.720.
"SM 7500-U C (96)" means
Method 7500-U C, "Uranium", "Isotopic Method", only the
version in the 20
th
edition. Referenced in Section 611.720.
"SM 7500-U C (00)" means
Method 7500-U C, "Uranium", "Isotopic Method", only the
version in the 21
st
, 22
nd
, and 23
rd
editions.
Referenced in Section 611.720.
"SM 9060 A (97)" means
Method 9060 A, "Samples", "Collection", only the version in
the 20
th
and 21
st
editions. Referenced in Section
611.1052.
"SM 9215 B (88)" means
Method 9215 B,
"Heterotrophic Plate Count", "Pour
Plate Method", only the version in the 18
th
edition.
Referenced in Section 611.531.
"SM 9215 B (94)" means
Method 9215 B, "Heterotrophic Plate Count", "Pour Plate Method",
only the version in the 19
th
and 20
th
editions.
Referenced in Section 611.531.
"SM 9215 B (00)" means
Method 9215 B, "Heterotrophic Plate Count", "Pour Plate Method",
only the version in the 21
st
edition. Referenced in Section
611.531.
"SM 9215 B (04)" means
Method 9215 B, "Heterotrophic Plate Count", "Pour Plate Method",
only the version in the 22
nd
edition. Referenced in Section
611.531.
"SM 9215 B (16)" means
Method 9215 B, "Heterotrophic Plate Count", "Pour Plate Method",
only the version in the 23
rd
edition. Referenced in Section
611.531.
"SM 9215 B (22)" means
Method 9215 B, "Heterotrophic Plate Count", "Pour Plate Method",
only the version in the 24
th
edition. Referenced in Section
611.531
od",
only the version in the 22
nd
edition. Referenced in Section
611.531.
"SM 9215 B (16)" means
Method 9215 B, "Heterotrophic Plate Count", "Pour Plate Method",
only the version in the 23
rd
edition. Referenced in Section
611.531.
"SM 9215 B (22)" means
Method 9215 B, "Heterotrophic Plate Count", "Pour Plate Method",
only the version in the 24
th
edition. Referenced in Section
611.531.
"SM 9221 A (93)" means
Method 9221 A, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Introduction", only the version in the 18
th
edition. Referenced in Section 611.531.
"SM 9221 A (94)" means
Method 9221 A, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Introduction", only the version in the 19
th
and 20
th
editions. Referenced in Section 611.531.
"SM 9221 A (99)" means
Method 9221 A, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Introduction", only the version in the 21
st
edition. Referenced in Section 611.531.
"SM 9221 A (06)" means
Method 9221 A, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Introduction", only the version in the 22
nd
edition. Referenced in Section 611.531.
"SM 9221 A (14)" means
Method 9221 A, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Introduction", only the version in the 23
rd
and 24
th
editions. Referenced in Section 611.531.
"SM 9221 B (93)" means
Method 9221 B, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Standard Total Coliform Fermentation Technique",
only the version in the 18
th
edition. Referenced in Section
611.531.
"SM 9221 B (94)" means
Method 9221 B, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Standard Total Coliform Fermentation Technique",
only the version in the 19
th
and 20
th
editions.
Referenced in Sections 611.531 and 611.1052
Coliform Group", "Standard Total Coliform Fermentation Technique",
only the version in the 18
th
edition. Referenced in Section
611.531.
"SM 9221 B (94)" means
Method 9221 B, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Standard Total Coliform Fermentation Technique",
only the version in the 19
th
and 20
th
editions.
Referenced in Sections 611.531 and 611.1052.
"SM 9221 B (99)" means
Method 9221 B, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Standard Total Coliform Fermentation Technique",
only the version in the 21
st
edition. Referenced in Sections
611.531 and 611.1052.
"SM 9221 B (06)" means
Method 9221 B, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Standard Total Coliform Fermentation Technique",
only the version in the 22
nd
edition. Referenced in Sections
611.531 and 611.1052.
"SM 9221 B (14)" means
Method 9221 B, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Standard Total Coliform Fermentation Technique",
only the version in the 23
rd
and 24
th
editions.
Referenced in Sections 611.531 and 611.1052.
"SM 9221 C (93)" means
Method 9221 C, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Estimation of Bacterial Density", only the
version in the 18
th
edition. Referenced in Section 611.531.
"SM 9221 C (94)" means
Method 9221 C, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Estimation of Bacterial Density", only the
version in the 19
th
and 20
th
editions. Referenced in
Section 611.531.
"SM 9221 C (99)" means
Method 9221 C, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Estimation of Bacterial Density", only the
version in the 21
st
edition. Referenced in Section 611.531.
"SM 9221 C (06)" means
Method 9221 C, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Estimation of Bacterial Density", only the
version in the 22
nd
edition
C (99)" means
Method 9221 C, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Estimation of Bacterial Density", only the
version in the 21
st
edition. Referenced in Section 611.531.
"SM 9221 C (06)" means
Method 9221 C, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Estimation of Bacterial Density", only the
version in the 22
nd
edition. Referenced in Section 611.531.
"SM 9221 C (14)" means
Method 9221 C, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Estimation of Bacterial Density", only the
version in the 23
rd
and 24
th
editions. Referenced in
Section 611.531.
"SM 9221 D (94)" means
Method 9221 D, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Presence-Absence (P-A) Coliform", only the
version in the 20
th
edition. Referenced in Section 611.1052.
"SM 9221 D (99)" means
Method 9221 D, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Presence-Absence (P-A) Coliform", only the
version in the 21
st
edition. Referenced in Section 611.1052.
"SM 9221 D (14)" means
Method 9221 D, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Presence-Absence (P-A) Coliform", only the
version in the 23
rd
and 24
th
editions. Referenced in
Section 611.1052.
"SM 9221 E (93)" means
Method 9221 E, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Fecal Coliform Procedure", only the version in
the 18
th
edition. Referenced in Section 611.531.
"SM 9221 E (94)" means
Method 9221 E, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Fecal Coliform Procedure", only the version in
the 19
th
and 20
th
editions. Referenced in Section
611.531.
"SM 9221 E (99)" means
Method 9221 E, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Fecal Coliform Procedure", only the version in
the 21
st
edition. Referenced in Section 611.531
"Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Fecal Coliform Procedure", only the version in
the 19
th
and 20
th
editions. Referenced in Section
611.531.
"SM 9221 E (99)" means
Method 9221 E, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Fecal Coliform Procedure", only the version in
the 21
st
edition. Referenced in Section 611.531.
"SM 9221 E (06)" means
Method 9221 E, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Fecal Coliform Procedure", only the version in
the 22
nd
edition. Referenced in Section 611.531.
"SM 9221 E (14)" means
Method 9221 E, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Thermotolerant (Fecal) Coliform Procedure",
only the version in the 23
rd
and 24
th
editions.
Referenced in Section 611.531.
"SM 9221 F (94)" means
Method 9221 F,
"Multiple-Tube Fermentation
Technique for Members of the Coliform Group", "Escherichia Coli
Procedure (Proposed)", only the version in the 20
th
edition.
Referenced in Sections 611.802 and 611.1052.
"SM 9221 F (06)" means
Method 9221 F, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Escherichia Coli Procedure Using Fluorogenic
Substrate", only the version in the 22
nd
edition. Referenced
in Sections 611.802 and 611.1052.
"SM 9221 F (14)" means
Method 9221 F, "Multiple-Tube Fermentation Technique for Members of the
Coliform Group", "Escherichia Coli Procedure Using Fluorogenic
Substrate", only the version in the 23
rd
and 24
th
editions. Referenced in Sections 611.802 and 611.1052.
"SM 9222 A (91)" means
Method 9222 A, "Membrane Filter Technique for Members of the Coliform
Group", "Introduction", only the version in the 18
th
edition. Referenced in Section 611.531.
"SM 9222 A (94)" means
Method 9222 A, "Membrane Filter Technique for Members of the Coliform
Group", "Introduction", only the version in the 19
th
edition. Referenced in Section 611.531
611.802 and 611.1052.
"SM 9222 A (91)" means
Method 9222 A, "Membrane Filter Technique for Members of the Coliform
Group", "Introduction", only the version in the 18
th
edition. Referenced in Section 611.531.
"SM 9222 A (94)" means
Method 9222 A, "Membrane Filter Technique for Members of the Coliform
Group", "Introduction", only the version in the 19
th
edition. Referenced in Section 611.531.
"SM 9222 A (97)" means
Method 9222 A, "Membrane Filter Technique for Members of the Coliform
Group", "Introduction", only the version in the 20
th
and 21
st
editions. Referenced in Section 611.531.
"SM 9222 A (06)" means
Method 9222 A, "Membrane Filter Technique for Members of the Coliform
Group", "Introduction", only the version in the 22
nd
edition. Referenced in Section 611.531.
"SM 9222 A (15)" means
Method 9222 A, "Membrane Filter Technique for Members of the Coliform
Group", "Introduction", only the version in the 23
rd
edition. Referenced in Section 611.531.
"SM 9222 A (22)" means
Method 9222 A, "Membrane Filter Technique for Members of the Coliform
Group", "Introduction", only the version in the 24
th
edition. Referenced in Section 611.531.
"SM 9222 B (91)" means
Method 9222 B, "Membrane Filter Technique for Members of the Coliform
Group", "Standard Total Coliform Membrane Filter Procedure",
only the version in the 18
th
edition. Referenced in Section
611.531.
"SM 9222 B (94)" means
Method 9222 B, "Membrane Filter Technique for Members of the Coliform
Group", "Standard Total Coliform Membrane Filter Procedure",
only the version in the 19
th
edition. Referenced in Section
611.531.
"SM 9222 B (97)" means
Method 9222 B, "Membrane Filter Technique for Members of the Coliform
Group", "Standard Total Coliform Membrane Filter Procedure",
only the version in the 20
th
and 21
st
editions.
Referenced in Sections 611.531 and 611.1052
the Coliform
Group", "Standard Total Coliform Membrane Filter Procedure",
only the version in the 19
th
edition. Referenced in Section
611.531.
"SM 9222 B (97)" means
Method 9222 B, "Membrane Filter Technique for Members of the Coliform
Group", "Standard Total Coliform Membrane Filter Procedure",
only the version in the 20
th
and 21
st
editions.
Referenced in Sections 611.531 and 611.1052.
"SM 9222 B (15)" means
Method 9222 B, "Membrane Filter Technique for Members of the Coliform
Group", "Standard Total Coliform Membrane Filter Procedure using Endo
Media", only the version in the 23
rd
edition. Referenced in
Sections 611.531 and 611.1052.
"SM 9222 B (22)" means
Method 9222 B, "Membrane Filter Technique for Members of the Coliform
Group", "Standard Total Coliform Membrane Filter Procedure using Endo
Media", only the version in the 24
th
edition. Referenced in
Section 611.531.
"SM 9222 C (91)" means
Method 9222 C,
"Membrane Filter Technique for
Members of the Coliform Group", "Delayed-Incubation Total Coliform
Procedure", only the version in the 18
th
edition. Referenced
in Section 611.531.
"SM 9222 C (94)" means
Method 9222 C, "Membrane Filter Technique for Members of the Coliform
Group", "Delayed-Incubation Total Coliform Procedure", only the version
in the 19
th
edition. Referenced in Section 611.531.
"SM 9222 C (97)" means
Method 9222 C, "Membrane Filter Technique for Members of the Coliform
Group", "Delayed-Incubation Total Coliform Procedure", only the
version in the 20
th
and 21
st
editions. Referenced in
Sections 611.531 and 611.1052.
"SM 9222 C (15)" means
Method 9222 C, "Membrane Filter Technique for Members of the Coliform
Group", "Delayed-Incubation Total Coliform Procedure", only the
version in the 23
rd
edition. Referenced in Sections 611.531 and
611.1052.
"SM 9222 C (22)" means
Method 9222 C, "Membrane Filter Technique for Members of the Coliform
Group", "Delayed-Incubation Total Coliform Procedure", only the
version in the 24
th
edition
ethod 9222 C, "Membrane Filter Technique for Members of the Coliform
Group", "Delayed-Incubation Total Coliform Procedure", only the
version in the 23
rd
edition. Referenced in Sections 611.531 and
611.1052.
"SM 9222 C (22)" means
Method 9222 C, "Membrane Filter Technique for Members of the Coliform
Group", "Delayed-Incubation Total Coliform Procedure", only the
version in the 24
th
edition. Referenced in Section 611.531 and
611.1052.
"SM 9222 D (91)" means
Method 9222 D, "Membrane Filter Technique for Members of the Coliform
Group", "Fecal Coliform Membrane Filter Procedure", only the
version in the 18
th
edition. Referenced in Section 611.531.
"SM 9222 D (94)" means
Method 9222 D, "Membrane Filter Technique for Members of the Coliform
Group", "Fecal Coliform Membrane Filter Procedure", only the
version in the 19
th
edition. Referenced in Section 611.531.
"SM 9222 D (97)" means
Method 9222 D, "Membrane Filter Technique for Members of the Coliform
Group", "Fecal Coliform Membrane Filter Procedure", only the
version in the 20
th
and 21
st
editions. Referenced in
Sections 611.531 and 611.1004.
"SM 9222 D (06)" means
Method 9222 D, "Membrane Filter Technique for Members of the Coliform
Group", "Thermotolerant (Fecal) Coliform Membrane Filter Procedure",
only the version in the 22
nd
edition. Referenced in Section
611.531.
"SM 9222 D (15)" means
Method 9222 D, "Membrane Filter Technique for Members of the Coliform
Group", "Thermotolerant (Fecal) Coliform Membrane Filter Procedure",
only the version in the 23
rd
edition. Referenced in Section
611.531.
"SM 9222 D (22)" means
Method 9222 B, "Membrane Filter Technique for Members of the Coliform
Group", "Thermotolerant (Fecal) Coliform Membrane Filter Procedure"
only the version in the 24
th
edition. Referenced in Section
611.531.
"SM 9222 G (97)" means
Method 9222 G, "Membrane Filter Technique for Members of the Coliform
Group", "MF Partition Procedure", only the version in the 20
th
and 21
st
editions
2)" means
Method 9222 B, "Membrane Filter Technique for Members of the Coliform
Group", "Thermotolerant (Fecal) Coliform Membrane Filter Procedure"
only the version in the 24
th
edition. Referenced in Section
611.531.
"SM 9222 G (97)" means
Method 9222 G, "Membrane Filter Technique for Members of the Coliform
Group", "MF Partition Procedure", only the version in the 20
th
and 21
st
editions. Referenced in Sections 611.802, 611.1004, and
611.1052.
"SM 9222 H (15)" means
Method 9222 H, "Membrane Filter Technique for Members of the Coliform
Group", "Partitioning E. coli from MF Total Coliform and E. coli
using EC-MUG Broth", only the version in the 23
rd
edition.
Referenced in Section 611.1052.
"SM 9222 H (22)" means
Method 9222 H, "Membrane Filter Technique for Members of the Coliform
Group", "Partitioning E. coli from MF Total Coliform and E. coli
using EC-MUG Broth", only the version in the 24
th
edition.
Referenced in Section 611.1052.
"SM 9222 I (15)" means
Method 9222 I, "Membrane Filter Technique for Members of the Coliform
Group", "Partitioning E. coli from MF Total Coliform and E. coli
using NA-MUG Agar", only the version in the 23
rd
edition.
Referenced in Sections 611.802 and 611.1052.
"SM 9222 I (22)" means
Method 9222 I, "Membrane Filter Technique for Members of the Coliform
Group", "Partitioning E. coli from MF Total Coliform and E. coli
using NA-MUG Agar", only the version in the 24
th
edition.
Referenced in Section 611.802 and 611.1052.
"SM 9222 J (15)" means
Method 9222 J, "Membrane Filter Technique for Members of the Coliform
Group", "Simultaneous Detection of Total Coliform and E. coli by
Dual-Chromogen Membrane Filter Procedure", only the version in the 23
rd
edition. Referenced in Sections 611.802 and 611.1052.
"SM 9222 J (22)" means
Method 9222 J, "Membrane Filter Technique for Members of the Coliform
Group", "Simultaneous Detection of Total Coliform and E. coli by
Dual-Chromogen Membrane Filter Procedure", only the version in the 24
th
edition
Total Coliform and E. coli by
Dual-Chromogen Membrane Filter Procedure", only the version in the 23
rd
edition. Referenced in Sections 611.802 and 611.1052.
"SM 9222 J (22)" means
Method 9222 J, "Membrane Filter Technique for Members of the Coliform
Group", "Simultaneous Detection of Total Coliform and E. coli by
Dual-Chromogen Membrane Filter Procedure", only the version in the 24
th
edition. Referenced in Section 611.802 and 611.1052.
"SM 9223 (92)" means
Method 9223, "Chromogenic Substrate Coliform Test (Proposed)" (also
referred to as the variations "Colilert
®
" and "Colisure
™
"
depending on the medium used), only the version in the 18
th
edition. Referenced in Section 611.531.
"SM 9223 (94)" means
Method 9223, "Chromogenic Substrate Coliform" (also referred to as
the variations "Colilert
®
" and "Colisure
™
"
depending on the medium used), only the version in the 19
th
edition. Referenced in Section 611.531.
"SM 9223 (97)" means
Method 9223, "Enzyme Substrate Coliform" (also referred to as the
variations "Colilert
®
" and "Colisure
™
"
depending on the medium used), only the version in the 20
th
and 21
st
editions. Referenced in Sections 611.531.
"SM 9223 B (92)" means
Method 9223 B,
"Chromogenic Substrate Coliform
Test (Proposed)", "Chromogenic Substrate" (also referred to as
the variations "Colilert
®
", "Colisure
™
",
and "Colilert-18
®
" depending on the medium used), only the
version in the 18
th
edition. Referenced in Section 611.1004.
"SM 9223 B (94)" means
Method 9223 B, "Chromogenic Substrate Coliform", "Chromogenic
Substrate" (also referred to as the variations "Colilert
®
"
and "Colisure
™
" depending on the medium used), only the
version in the 19
th
edition. Referenced in Section 611.1004.
"SM 9223 B (97)" means
Method 9223 B, "Enzyme Substrate Coliform", "Chromogenic
Substrate" (also referred to as the variations "Colilert
®
"
and "Colisure
™
" depending on the medium used), only the
version in the 20
th
and 21
st
editions
to as the variations "Colilert
®
"
and "Colisure
™
" depending on the medium used), only the
version in the 19
th
edition. Referenced in Section 611.1004.
"SM 9223 B (97)" means
Method 9223 B, "Enzyme Substrate Coliform", "Chromogenic
Substrate" (also referred to as the variations "Colilert
®
"
and "Colisure
™
" depending on the medium used), only the
version in the 20
th
and 21
st
editions. Referenced in
Sections 611.802 and 611.1004.
"SM 9223 B (04)" means
Method 9223 B, "Enzyme Substrate Coliform", "Enzyme Substrate"
(also referred to as the variations "Colilert
®
" and "Colisure
™
"
depending on the medium used), only the version in the 22
nd
edition. Referenced in Sections 611.531, 611.802, and 611.1004.
"SM 9223 B (16)" means
Method 9223 B, "Enzyme Substrate Coliform", "Enzyme Substrate"
(also referred to as the variations "Colilert
®
" and "Colisure
™
"
depending on the medium used), only the version in the 23
rd
and 24
th
editions. Referenced in Sections 611.531, 611.802, and 611.1052.
"SM 9230 B (93)" means
Method 9230 B, "Fecal Streptococcus and Enterococcus Groups", "Multiple-Tube
Techniques", only the version in the 20
th
and 21
st
editions. Referenced in Section 611.802.
"SM 9230 B (04)" means
Method 9230 B, "Fecal Streptococcus and Enterococcus Groups", "Multiple-Tube
Techniques", only the version from Standard Methods Online as Method 9230
B-04. Referenced in Section 611.802.
"SM 9230 B (13)" means
Method 9230 B, "Fecal Streptococcus and Enterococcus Groups", "Multiple-Tube
Techniques", only the version in the 23
rd
edition. Referenced
in Section 611.802.
"SM 9230 B (22)" means
Method 9230 B, "Fecal Streptococcus and Enterococcus Groups", "Multiple-Tube
Techniques", only the version in the 24
th
edition. Referenced
in Section 611.802.
"SM 9230 C (93)" means
Method 9230 C, "Fecal Streptococcus and Enterococcus Groups", "Membrane
Filter Techniques", only the version in the 20
th
edition.
Referenced in Section 611.802
nced
in Section 611.802.
"SM 9230 B (22)" means
Method 9230 B, "Fecal Streptococcus and Enterococcus Groups", "Multiple-Tube
Techniques", only the version in the 24
th
edition. Referenced
in Section 611.802.
"SM 9230 C (93)" means
Method 9230 C, "Fecal Streptococcus and Enterococcus Groups", "Membrane
Filter Techniques", only the version in the 20
th
edition.
Referenced in Section 611.802.
"SM 9230 C (13)" means
Method 9230 C, "Fecal Enterococcus/Streptococcus Groups", "Membrane
Filter Techniques", only the version in the 23
rd
edition.
Referenced in Section 611.802.
"SM 9230 C (22)" means
Method 9230 C, "Fecal Streptococcus and Enterococcus Groups", "Membrane
Filter Techniques", only the version in the 24
th
edition.
Referenced in Section 611.802.
"SM 9230 D (13)" means
Method 9230 D, "Fecal Enterococcus/Streptococcus Groups", "Fluorogenic
Substrate Enterococcus", only the version in the 23
rd
edition.
Referenced in Section 611.802.
"SM 9230 D (22)" means
Method 9230 D, "Fecal Streptococcus and Enterococcus Groups", "Fluorogenic
Substrate Enterococcus", only the version in the 24
th
edition.
Referenced in Section 611.802.
BOARD NOTE: The publication dates
of the several "Standard Methods for the Examination of Water and
Wastewater" editions containing approved methods:
13
th
edition, 1971
17
th
edition, 1989
18
th
edition, 1992
Supplement to 18
th
edition, 1994
19
th
edition, 1995
Supplement to 19
th
edition, 1996
20
th
edition, 1998
21
st
edition, 2005
22
nd
edition, 2012
23
rd
edition, 2017
24
th
edition, 2023
"Syngenta AG-625 (01)"
means "Method AG-625: Atrazine in Drinking Water by Immunoassay"
(February 2001), Syngenta Crop Protection, Inc. Available from publisher, 410
Swing Road, Post Office Box 18300, Greensboro, NC 27419 (336-632–6000).
Referenced in Section 611.645.
"Systea Easy (1-Reagent) (09)"
means "Nitrate by Discrete Analysis: Systea Easy (1-Reagent) Nitrate
Method (Colorimetric, Automated, 1 Reagent)" (February 4, 2009)
5: Atrazine in Drinking Water by Immunoassay"
(February 2001), Syngenta Crop Protection, Inc. Available from publisher, 410
Swing Road, Post Office Box 18300, Greensboro, NC 27419 (336-632–6000).
Referenced in Section 611.645.
"Systea Easy (1-Reagent) (09)"
means "Nitrate by Discrete Analysis: Systea Easy (1-Reagent) Nitrate
Method (Colorimetric, Automated, 1 Reagent)" (February 4, 2009).
Available from Systea Scientific LLC, 900 Jorie Blvd., Suite 35, Oak Brook, IL 60523
(630-645-0600); NEMI; and USEPA, OGWDW (under "Inorganic Contaminants and
Other Inorganic Constituents (PDF)"). Referenced in Section 611.611.
Technicon Methods. Available from
Bran + Luebbe, 1025 Busch Parkway, Buffalo Grove, IL 60089.
"Technicon #129-71W (72)"
means "Fluoride in Water and Wastewater" (December 1972), Industrial
Method #129-71W. Referenced in Section 611.611. See 40 CFR 141.23(k)(1),
footnote 11.
"Technicon
#380-75WE (76)
" means "Fluoride in Water and
Wastewater" (February 1976), #380-75WE. See 40 CFR 141.23(k)(1), footnote
11, referenced in Section 611.611.
Tecta Methods. Available from IDEXX
Laboratories, Inc., One IDEXX Drive, Westbrook, Maine 04092 (800-548-6733;
https://www.idexx.com/en/water/other-products-services/tecta-water-microbiology-system/
and USEPA, OGWDW (under "Ground Water Rule (PDF)" and "Revised
Total Coliforms Rules (PDF)").
"Tecta (14)" means "TECTA
™
EC/TC medium and the TECTA
™
Instrument: a Presence/Absence Method
for Simultaneous Detection of Total Coliforms and Escherichia coli (E.coli) in
Drinking Water", Version 1.0 (May 22, 2014). Referenced in Sections
611.802 and 611.1052.
"Tecta (17)" means "TECTA
™
EC/TC medium and the TECTA
™
Instrument: a Presence/Absence Method
for Simultaneous Detection of Total Coliforms and Escherichia coli (E.coli) in
Drinking Water", Version 2.0 (March 20, 2017). Referenced in Sections
611.802 and 611.1052
orms and Escherichia coli (E.coli) in
Drinking Water", Version 1.0 (May 22, 2014). Referenced in Sections
611.802 and 611.1052.
"Tecta (17)" means "TECTA
™
EC/TC medium and the TECTA
™
Instrument: a Presence/Absence Method
for Simultaneous Detection of Total Coliforms and Escherichia coli (E.coli) in
Drinking Water", Version 2.0 (March 20, 2017). Referenced in Sections
611.802 and 611.1052.
"Thermo-Fisher 557.1 (17)"
means "Thermofisher Method 557.1: Determination of Haloacetic Acids in
Drinking Water using Two-Dimensional Ion Chromatography with Suppressed
Conductivity Detection", Version 1.0 (January 2017). Available from
Thermo-Fisher Scientific, 490 Lakeside Dr, Sunnyvale, CA 94085 (800-556-2323;
www.thermofisher.com) and USEPA, OGWDW (under "Disinfection Byproduct
Rules (PDF)"). Referenced in Section 611.611.
"Thermo-Fisher Discrete
Analyzer (16)" means "Application Note: Drinking Water
Orthophosphate Method for Thermo Scientific Gallery Discrete Analyzer",
Revision 5 (February 18, 2016). Available from Thermo-Fisher Scientific,
Ratastie 2, 01620 Vantaa, Finland and USEPA, OGWDW (under "Inorganic
Contaminants and Other Inorganic Constituents (PDF)"). Referenced in
Section 611.611.
USEPA Methods
Numbered Methods
"USEPA H-02 (84)" means
Method H-02, "Radiochemical Determination of Tritium in Water − Dioxane
Method", in USEPA Radiochemistry Procedures (84). Referenced in Section
611.720.
BOARD
NOTE: Also available from USEPA, OGWDW (under "Radionuclides (PDF)").
"USEPA Ra-03 (84)" means
Method Ra-03, "Radiochemical Determination of Radium-226 in Water Samples",
in USEPA Radiochemistry Procedures (84). Referenced in Section 611.720.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Radionuclides (PDF)").
"USEPA Ra-04 (84)" means
Method Ra-04, "Radiochemical Determination of Radium-226 − De-emanation
Procedure", in USEPA Radiochemistry Procedures (84). Referenced in
Section 611.720.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Radionuclides (PDF)")
iochemistry Procedures (84). Referenced in Section 611.720.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Radionuclides (PDF)").
"USEPA Ra-04 (84)" means
Method Ra-04, "Radiochemical Determination of Radium-226 − De-emanation
Procedure", in USEPA Radiochemistry Procedures (84). Referenced in
Section 611.720.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Radionuclides (PDF)").
"USEPA Ra-05 (84)" means
Method Ra-05, "Radiochemical Determination of Radium-228 in Water Samples",
in USEPA Radiochemistry Procedures (84). Referenced in Section 611.720.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Radionuclides (PDF)").
"USEPA Sr-04 (84)" means
Method Sr-04, "Radiochemical Determination of Radiostrontium in Water, Sea
Water and Other Aqueous Media", in USEPA Radiochemistry Procedures (84).
Referenced in Section 611.720.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Radionuclides (PDF)").
"USEPA 00-01 (84)" means
Method 00-01, "Radiochemical Determination of Gross Alpha and Gross Beta
Activity in Water", in USEPA Radiochemistry Procedures (84). Referenced
in Section 611.720.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Radionuclides (PDF)").
"USEPA 00-02 (84)" means
Method 00-02, "Radiochemical Determination of Gross Alpha Activity in
Drinking Water by Coprecipitation", in USEPA Radiochemistry Procedures
(84). Referenced in Section 611.720.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Radionuclides (PDF)").
"USEPA 00-07 (84)" means
Method 00-07, "Radiochemical Determination of Thorium and Uranium in Water",
in USEPA Radiochemistry Procedures (84). Referenced in Section 611.720.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Radionuclides (PDF)").
"USEPA 100.1 (83)" means
"Method 100.1: Analytical Method for Determination of Asbestos in Water"
(September 1983), USEPA, Environmental Research Laboratory, document number EPA
600/4-83-043
mical Determination of Thorium and Uranium in Water",
in USEPA Radiochemistry Procedures (84). Referenced in Section 611.720.
BOARD NOTE: Also available from
USEPA, OGWDW (under "Radionuclides (PDF)").
"USEPA 100.1 (83)" means
"Method 100.1: Analytical Method for Determination of Asbestos in Water"
(September 1983), USEPA, Environmental Research Laboratory, document number EPA
600/4-83-043. Available from NEMI; NTRL (document number PB83-260471) and
USEPA, NSCEP (search for "600483043"). Referenced in Section
611.611.
"USEPA 100.2 (94)" means
"Method 100.2: Determination of Asbestos Structures over 10-mm in Length
in Drinking Water" (June 1994), USEPA, Environmental Monitoring Systems
Laboratory, document number EPA 600/R-94-134. Available from NEMI; NTRL
(document number PB94-201902); USEPA, NSCEP (search for "600R94134");
and USEPA, OGWDW (under "Inorganic Contaminants and Other Inorganic
Constituents (PDF)"). Referenced in Section 611.611.
"USEPA 127 (21)" means "Method
127: Determination of Monochloramine Concentration in Drinking Water",
document number EPA 815-B-21-004, (January 2021). Available from USEPA, NSCEP
(search for "815B21004"). Referenced in Section 611.531.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 150.1 (71)" means
"pH: Method 150.1 (Electrometric)" (1971), in USEPA Inorganic
Methods (83). Referenced in Section 611.611.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 150.2 (82)" means
"pH, Continuous Monitoring (Electrometric) − Method 150.2"
(December 1982), in USEPA Inorganic Methods (83). Referenced in Section
611.611.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 150.3 (17)" means
"Method 150.3: Determination of pH in Drinking Water", Version 1.0
(February 2017), USEPA, Office of Ground Water and Drinking Water, document
number EPA 815/B-17/001
" means
"pH, Continuous Monitoring (Electrometric) − Method 150.2"
(December 1982), in USEPA Inorganic Methods (83). Referenced in Section
611.611.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 150.3 (17)" means
"Method 150.3: Determination of pH in Drinking Water", Version 1.0
(February 2017), USEPA, Office of Ground Water and Drinking Water, document
number EPA 815/B-17/001. Available from USEPA, NSCEP (search for "815B17001")
and USEPA, OGWDW (under "Disinfection Byproduct Rules (PDF)" and "Inorganic
Contaminants and Other Inorganic Constituents (PDF)"). Referenced in
Section 611.611.
"USEPA 180.1 (93)" means
"Method 180.1: Determination of Turbidity by Nephelometry", Revision
2.0 (August 1993), in USEPA Environmental Inorganic Methods (93). Referenced
in Section 611.531.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 200.5 (03)" means
"Method 200.5: Determination of Trace Elements in Drinking Water by
Axially Viewed Inductively Coupled Plasma-Atomic Emission Spectrometry",
Revision 4.2 (October 2003), USEPA, National Exposure Research Laboratory,
document number EPA 600/R-06/115. Available from NEMI; USEPA, NSCEP (search
for "600R06115"); and USEPA, OGWDW (under "Disinfection
Byproduct Rules (PDF),"
"Inorganic
Contaminants and Other Inorganic Constituents (PDF)
,
" and "Secondary Contaminants (PDF)").
Referenced in Sections 611.611 and 611.612.
"USEPA 200.7 (94)" means
"Method 200.7: Determination of Metals and Trace Elements in Water and
Wastes by Inductively Coupled Plasma-Atomic Emission Spectrometry",
Revision 4.4 (May 1994), in USEPA Environmental Metals Methods (94).
Referenced in Sections 611.600, 611.611, and 611.612.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 200.8 (94)" means
"Method 200.8: Determination of Trace Elements in Water and Wastes by
Inductively Coupled Plasma-Atomic Emission Spectrometry", Revision 5.3
(May 1994), in USEPA Environmental Metals Methods (94)
vision 4.4 (May 1994), in USEPA Environmental Metals Methods (94).
Referenced in Sections 611.600, 611.611, and 611.612.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 200.8 (94)" means
"Method 200.8: Determination of Trace Elements in Water and Wastes by
Inductively Coupled Plasma-Atomic Emission Spectrometry", Revision 5.3
(May 1994), in USEPA Environmental Metals Methods (94). Referenced in Sections
611.600, 611.611, 611.612, and 611.720.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 200.9 (94)" means
"Method 200.9: Determination of Metals and Trace Elements in Water by
Ultrasonic Nebulization Inductively Coupled Plasma-Atomic Emission Spectrometry",
Revision 2.2 (May 1994), in USEPA Environmental Metals Methods (94).
Referenced in Sections 611.600, 611.611, and 611.612.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 245.1 (91)" means
"Method 245.1: Determination of Mercury in Water by Cold Vapor Atomic
Absorption Spectrometry", Revision 2.3 (April 1991), in USEPA
Environmental Metals Methods (94). Referenced in Section 611.611.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 245.2 (74)" means
"Mercury: Method 245.2 (Automated Cold Vapor Technique)" (1974), in
USEPA Inorganic Methods (83). Referenced in Section 611.611.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 300.0 (93)" means
"Method 300.0: Determination of Inorganic Anions by Ion Chromatography",
Revision 2.1 (August 1993), in USEPA Environmental Inorganic Methods (93).
Referenced in Sections 611.381 and 611.611.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 300.1 (97)" means
"Method 300.1: Determination of Inorganic Anions in Drinking Water by Ion
Chromatography", Revision 1.0 (September 1997), in USEPA Organic and
Inorganic Methods (00). Referenced in Sections 611.381 and 611.611.
BOARD NOTE: Also individually
available from NEMI
ds (93).
Referenced in Sections 611.381 and 611.611.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 300.1 (97)" means
"Method 300.1: Determination of Inorganic Anions in Drinking Water by Ion
Chromatography", Revision 1.0 (September 1997), in USEPA Organic and
Inorganic Methods (00). Referenced in Sections 611.381 and 611.611.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 302.0 (09)" means
"Method 302.0: Determination of Bromate in Drinking Water Using
Two-Dimensional Ion Chromatography with Suppressed Conductivity Detection"
(September 2009), USEPA, Office of Water, document number EPA 815/B-09/014.
Available from NEMI; USEPA, NSCEP (search "815B09014"); and USEPA,
OGWDW
(under "Disinfection
Byproduct Rules (PDF)")
. Referenced in Sections 611.381 and 611.382.
"USEPA 317.0 (01)" means
"Method 317.0: Determination of Inorganic Oxyhalide Disinfection
By-Products in Drinking Water Using Ion Chromatography with the Addition of a
Postcolumn Reagent for Trace Bromate Analysis", Revision 2.0 (July 2001),
USEPA, Office of Ground Water and Drinking Water, Technical Support Center,
document number EPA 815/B-01/001. Available from NEMI; USEPA, NSCEP (search "815B01001");
and USEPA, OGWDW (under "Disinfection Byproduct Rules (PDF)").
Referenced in Sections 611.381 and 611.382.
"USEPA 321.8 (97)" means
"Method 321.8: Determination of Bromate in Drinking Waters by Ion
Chromatography Inductively Coupled Plasma/Mass Spectrometry", Revision 1.0
(December 1997), in USEPA Organic and Inorganic Methods (00). Referenced in
Sections 611.381 and 611.382.
BOARD NOTE: Also individually
available from NEMI
Byproduct Rules (PDF)").
Referenced in Sections 611.381 and 611.382.
"USEPA 321.8 (97)" means
"Method 321.8: Determination of Bromate in Drinking Waters by Ion
Chromatography Inductively Coupled Plasma/Mass Spectrometry", Revision 1.0
(December 1997), in USEPA Organic and Inorganic Methods (00). Referenced in
Sections 611.381 and 611.382.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 326.0 (02)" means
"Method 326.0: Determination of Inorganic Oxyhalide Disinfection By-Products
in Drinking Water Using Ion Chromatography Incorporating the Addition of a
Suppressor Acidified Postcolumn Reagent for Trace Bromate Analysis",
Revision 1.0 (June 2002), USEPA, Office of Ground Water and Drinking Water,
Technical Support Center, document number EPA 815/R-03/007. Available from
NEMI; NTRL (document number PB2003-107402); USEPA, NSCEP (search "815R03007");
and USEPA, OGWDW (under "Disinfection Byproduct Rules (PDF)").
Referenced in Sections 611.381 and 611.382.
"USEPA 327.0 (05)" means
"Method 327.0: Determination of Chlorine Dioxide and Chlorite Ion in
Drinking Water Using Lissamine Green B and Horseradish Peroxidase with
Detection by Visible Spectrophotometry", Revision 1.1 (May 2005), USEPA,
Office of Ground Water and Drinking Water, Technical Support Center, document
number EPA 815/R-05/008. Available from NEMI; USEPA, NSCEP (search "815R05008");
and USEPA, OGWDW (under "Disinfection Byproduct Rules (PDF)").
Referenced in Sections 611.381 and 611.531.
"USEPA 334.0 (09)" means
"Method 334.0: Determination of Residual in Drinking Water Using an
On-line Chlorine Analyzer", Version 1.0 (September 2009), USEPA, Office of
Ground Water and Drinking Water, Technical Support Center, document number EPA
815/B-09/013. Available from NEMI; USEPA, NSCEP (search "815B09013");
and USEPA, OGWDW (under "Disinfection Byproduct Rules (PDF)").
Referenced in Sections 611.381 and 611.531
od 334.0: Determination of Residual in Drinking Water Using an
On-line Chlorine Analyzer", Version 1.0 (September 2009), USEPA, Office of
Ground Water and Drinking Water, Technical Support Center, document number EPA
815/B-09/013. Available from NEMI; USEPA, NSCEP (search "815B09013");
and USEPA, OGWDW (under "Disinfection Byproduct Rules (PDF)").
Referenced in Sections 611.381 and 611.531.
"USEPA 335.4 (93)" means
"Method 335.4: Determination of Total Cyanide by Semi-Automated
Colorimetry", Revision 1.0 (August 1993), in USEPA Environmental Inorganic
Methods (93). Referenced in Section 611.611.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 353.2 (93)" means
"Method 353.2: Determination of Inorganic Anions by Ion Chromatography",
Revision 2.0 (August 1993), in USEPA Environmental Inorganic Methods (93).
Referenced in Section 611.611.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 365.1 (93)" means
"Method 365.1: Determination of Phosphorus by Automated Colorimetry",
Revision 2.0 (August 1993), in USEPA Environmental Inorganic Methods (93).
Referenced in Section 611.611.
BOARD NOTE: Also individually
available from NEMI and USEPA, OGWDW (under "Inorganic Contaminants and
Other Inorganic Constituents (PDF)").
"USEPA 415.3 (05)" means
"Method 415.3: Determination of Total Organic Carbon and Specific UV
Absorbance at 254 nm in Source Water and Drinking Water", Revision 1.1
(February 2005), USEPA, National Exposure Research Laboratory, document number
EPA 600/R05-055. Available from USEPA, NSCEP (search "600R05055")
and USEPA, OGWDW (under "Disinfection Byproduct Rules (PDF)").
Referenced in Section 611.381.
"USEPA 415.3 (09)" means
"Method 415.3, "Determination of Total Organic Carbon and Specific UV
Absorbance at 254 nm in Source Water and Drinking Water", Revision 1.2
(September 2009), USEPA, National Exposure Research Laboratory, document number
EPA 600/R09-122. Referenced in Section 611.381
055")
and USEPA, OGWDW (under "Disinfection Byproduct Rules (PDF)").
Referenced in Section 611.381.
"USEPA 415.3 (09)" means
"Method 415.3, "Determination of Total Organic Carbon and Specific UV
Absorbance at 254 nm in Source Water and Drinking Water", Revision 1.2
(September 2009), USEPA, National Exposure Research Laboratory, document number
EPA 600/R09-122. Referenced in Section 611.381. Available from NEMI; USEPA,
NSCEP (search "600R09122"); and USEPA, OGWDW (under "Disinfection
Byproduct Rules (PDF)").
"USEPA 502.2 (95)" means
"Method 502.2: Volatile Organic Compounds in Water by Purge and Trap
Capillary Column Gas Chromatography with Photoionization and Electrolytic
Conductivity Detectors in Series", Revision 2.1 (1995), in USEPA Organic
Methods − Supplement III (95). Referenced in Sections 611.381 and
611.645.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 504.1 (95)" means
"Method 504.1: 1,2-Dibromomethane (EDB), 1,2-Dibromo-3-Chloropropane
(DBCP), and 1,2,3-Trichloropropane (123TCP) in Water by Microextraction and Gas
Chromatography", Revision 1.1 (1995), in USEPA Organic Methods − Supplement
III (95). Referenced in Section 611.645.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 505 (95)" means "Method
505: Analysis of Organohalide Pesticides and Commercial Polychlorinated
Biphenyl (PCB) Products in Water by Microextraction and Gas Chromatography",
Revision 2.1 (1995), in USEPA Organic Methods − Supplement III (95).
Referenced in Sections 611.645 and 611.648.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 506 (95)" means "Method
506: Determination of Phthalate and Adipate Esters in Drinking Water by
Liquid-Liquid Extraction or Liquid-Solid Extraction and Gas Chromatography with
Photoionization Detection", Revision 1.1 (1995), in USEPA Organic Methods
− Supplement III (95). Referenced in Section 611.645.
BOARD NOTE: Also individually
available from NEMI
ividually
available from NEMI.
"USEPA 506 (95)" means "Method
506: Determination of Phthalate and Adipate Esters in Drinking Water by
Liquid-Liquid Extraction or Liquid-Solid Extraction and Gas Chromatography with
Photoionization Detection", Revision 1.1 (1995), in USEPA Organic Methods
− Supplement III (95). Referenced in Section 611.645.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 507 (95)" means "Method
507: Determination of Nitrogen- and Phosphorus-Containing Pesticides in Water
by Gas Chromatography with a Nitrogen-Phosphorus Detector", Revision 2.1
(1995), in USEPA Organic Methods − Supplement III (95). Referenced in
Sections 611.645 and 611.648.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 508 (95)" means "Method
508: Determination of Chlorinated Pesticides in Water by Gas Chromatography
with an Electron Capture Detector", Revision 3.1 (1995), in USEPA Organic
Methods − Supplement III (95). Referenced in Sections 611.645 and
611.648.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 508A (89)" means "Method
508A: Screening for Polychlorinated Biphenyls by Perchlorination and Gas
Chromatography", Revision 1.0 (1989), in USEPA Organic Methods (91).
Referenced in Sections 611.645 and 611.646.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 508.1 (95)" means
"Method 508.1: Determination of Chlorinated Pesticides, Herbicides, and
Organohalides by Liquid-Solid Extraction and Electron Capture Gas
Chromatography", Revision 2.0 (1995), in USEPA Organic Methods − Supplement
III (95). Referenced in Sections 611.645 and 611.648.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 515.1 (89)" means
"Method 515.1: Determination of Chlorinated Acids in Drinking Water by
Gas Chromatography with an Electron Capture Detector", Revision 4.1
quid-Solid Extraction and Electron Capture Gas
Chromatography", Revision 2.0 (1995), in USEPA Organic Methods − Supplement
III (95). Referenced in Sections 611.645 and 611.648.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 515.1 (89)" means
"Method 515.1: Determination of Chlorinated Acids in Drinking Water by
Gas Chromatography with an Electron Capture Detector", Revision 4.1
(1989), in USEPA Organic Methods (91). Referenced in Section 611.645.
"USEPA 515.2 (95)" means
"Method 515.2: Determination of Chlorinated Acids in Water Using
Liquid-Solid Extraction and Gas Chromatography with an Electron Capture
Detector", Revision 1.1 (1995), in USEPA Organic Methods − Supplement
III (95). Referenced in Section 611.645.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 515.3 (96)" means
"Method 515.3: Determination of Chlorinated Acids in Drinking Water by
Liquid-Liquid Extraction, Derivatization and Gas Chromatography with Electron
Capture Detection", Revision 1.0 (July 1996), in USEPA Organic and
Inorganic Methods (00). Referenced in Section 611.645.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 515.4 (00)" means
"Method 515.4: "Determination of Chlorinated Acids in Drinking Water
by Liquid-Liquid Microextraction, Derivatization and Fast Gas Chromatography
with Electron Capture Detection" Revision 1.0 (April 2000), USEPA, Office
of Ground Water and Drinking Water, Technical Support Center, document number
EPA 815/B-00/001. Available from NEMI; USEPA, NSCEP (search "815B00001");
and USEPA, OGWDW (under "Organic Contaminants (PDF)"). Referenced in
Section 611.645.
"USEPA 523 (11)" means "Method
523: Determination of Triazine Pesticides and Other Degradates in Drinking
Water by Gas Chromatography/Mass Spectrometry (GC/MS)", Version 1.0
(February 2011), USEPA, Office of Ground Water and Drinking Water, Standards
and Risk Management Division, Technical Support Center, document number EPA
815/R-11-002
Contaminants (PDF)"). Referenced in
Section 611.645.
"USEPA 523 (11)" means "Method
523: Determination of Triazine Pesticides and Other Degradates in Drinking
Water by Gas Chromatography/Mass Spectrometry (GC/MS)", Version 1.0
(February 2011), USEPA, Office of Ground Water and Drinking Water, Standards
and Risk Management Division, Technical Support Center, document number EPA
815/R-11-002. Available from USEPA, NSCEP (search "815R11002"); and
USEPA, OGWDW (under "Organic Contaminants (PDF)"). referenced in
Section 611.645.
"USEPA 524.2 (95)" means
"Method 524.2: Measurement of Purgeable Organic Compounds in Water by Capillary
Column Gas Chromatography/Mass Spectrometry", Revision 4.1 (1995), in
USEPA Organic Methods − Supplement III (95). Referenced in Section
611.645.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 524.3 (09)" means
"Method 524.3: Measurement of Purgeable Organic Compounds in Water by
Capillary Column Gas Chromatography/Spectrometry", Revision 1.0 (June
2009), USEPA, Office of Ground Water and Drinking Water, Standards and Risk
Management Division, Technical Support Center, document number EPA
815/B-09/009. Available from NEMI; USEPA, NSCEP (search for "815B09009");
and USEPA, OGWDW (under "Disinfection Byproduct Rules (PDF)" and "Organic
Contaminants (PDF)"). Referenced in Sections 611.381 and 611.645.
"USEPA 524.4 (13)" means
"Method 524.4, "Measurement of Purgeable Organic Compounds in Water
by Gas Chromatography/Spectrometry Using Nitrogen Purge Gas" (May 2013),
USEPA, Office of Ground Water and Drinking Water, Standards and Risk Management
Division, Technical Support Center, document number EPA 815/R-13/002.
Available from USEPA, NSCEP (search for "815R13002");
and USEPA, OGWDW (under "Disinfection Byproduct Rules
(PDF)" and "Organic Contaminants (PDF)")
. Referenced in
Sections 611.381 and 611.645
pectrometry Using Nitrogen Purge Gas" (May 2013),
USEPA, Office of Ground Water and Drinking Water, Standards and Risk Management
Division, Technical Support Center, document number EPA 815/R-13/002.
Available from USEPA, NSCEP (search for "815R13002");
and USEPA, OGWDW (under "Disinfection Byproduct Rules
(PDF)" and "Organic Contaminants (PDF)")
. Referenced in
Sections 611.381 and 611.645.
"USEPA 525.2 (95)" means
"Method 525.2: Determination of Organic Compounds in Drinking by
Liquid-Liquid Extraction and Capillary Column Gas Chromatography/Mass
Spectrometry", Revision 2.0 (1995), in USEPA Organic Methods − Supplement
III (95). Referenced in Section 611.645.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 525.3 (12)" means
"Method 525.3: Determination of Total Semivolatile Organic Chemicals in
Drinking Water by Solid Phase Extraction and Capillary Column Gas
Chromatography/Mass Spectrometry (GC/MS)", Version 1.0 (February 2012),
USEPA, National Exposure Research Laboratory, document number EPA
600/R-12/010. Available from USEPA, NSCEP (search "600R12010") and
USEPA, OGWDW (under "Organic Contaminants (PDF)"). Referenced in
Section 611.645.
"USEPA 531.1 (95)" means
"Method 531.1: Measurement of N-Methylcarbamoyloximes and
N-Methylcarbamates in Water by Direct Aqueous Injection HPLC with Post Column
Derivatization", Revision 3.1 (1995), in USEPA Organic Methods − Supplement
III (95). Referenced in Section 611.645.
BOARD NOTE: Also individually
available from NEMI.
"USEPA 531.2 (01)" means
"Method 531.2: Measurement of N-Methylcarbamoyloximes and
N-Methylcarbamates in Water by Direct Aqueous Injection HPLC with Postcolumn
Derivatization", Revision 1.0 (September 2001), USEPA, Office of Ground
Water and Drinking Water, Standards and Risk Management Division, Technical
Support Center, document number EPA 815/B-01/002. Available from NEMI; USEPA,
NSCEP (search "815B01002"); and USEPA, OGWDW (under "Organic
Contaminants (PDF)"). Referenced in Section 611.645
Water by Direct Aqueous Injection HPLC with Postcolumn
Derivatization", Revision 1.0 (September 2001), USEPA, Office of Ground
Water and Drinking Water, Standards and Risk Management Division, Technical
Support Center, document number EPA 815/B-01/002. Available from NEMI; USEPA,
NSCEP (search "815B01002"); and USEPA, OGWDW (under "Organic
Contaminants (PDF)"). Referenced in Section 611.645. See also and
"USEPA Method 533" means
"Method 533": Determination of Per- and Polyfluoroalkyl Substances
in Drinking Water by Isotope Dilution Anion Exchange Solid Phase Extraction and
Liquid Chromatography/Tandem Mass Spectrometry, 815-B-19-020, November 2019
"USEPA 536 (07)" means "Method
536: Determination of Triazine Pesticides and Other Degradates in Drinking
Water by Liquid Chromatography Electrospray Ionization Tandem Mass Spectrometry
(LC/ESI-MS/MS)", Version 1.0 (October 2007), USEPA Office of Ground Water
and Drinking Water, Technical Support Center, document number EPA
815/B-07/002. Available from USEPA, NSCEP (search
"815B07002
")
and USEPA, OGWDW (under "Organic Contaminants (PDF)"). Referenced in
Section 611.645.
"USEPA 547 (90)" means "Method
547: Determination of Glyphosate in Drinking Water by Direct-Aqueous-Injection
HPLC, Post-Column Derivatization, and Fluorescence Detection" (July 1990),
in USEPA Organic Methods − Supplement I (90). Referenced in Section
611.645.
"USEPA 548.1 (92)" means
"Method 548.1: Determination of Endothall in Drinking Water by
Ion-Exchange Extraction, Acidic Methanol Methylation and Gas Chromatography/Mass
Spectrometry", Revision 1.0 (August 1992), in USEPA Organic Methods
− Supplement II (92). Referenced in Section 611.645.
BOARD NOTE: Als
This text is long and has been trimmed here. Open the source document for the complete record.
This is a copy of a public record, reproduced as it was published. It is not legal advice, and it may not be the version a court would rely on. Check the official source before you cite it.