(1) Facilities.

(a) Pharmacies engaging in compounding shall have an adequate area for the orderly

compounding of prescriptions, including the placement of equipment and

materials. The drug compounding area for sterile preparations shall be separate

and distinct from the area used for the compounding of non-sterile drug

preparations. The area(s) used for compounding of drugs shall be maintained in a

good state of repair.

(b) Bulk drugs and other chemicals or materials used in the compounding of

prescription drug orders must be stored in adequately labeled containers in a clean,

dry area or, if required, under proper refrigeration.

(c) Adequate lighting and ventilation shall be provided in all drug-compounding

areas. Potable water shall be supplied under continuous positive pressure in a

plumbing system free of defects that could contribute to contamination of any

compounded drug preparation. Adequate washing facilities, easily accessible to

the compounding area(s) of the pharmacy shall be provided. These facilities shall

include, but not be limited to, hot and cold water, soap or detergent, and air dryers

or single-use towels.

(d) Sewage, trash, and other refuse in and from the pharmacy and immediate drug

compounding area(s) shall be disposed of in a safe and sanitary manner.

(2) Equipment.

(a) Equipment used in the compounding of drug preparation shall be of appropriate

design, appropriate capacity, and suitably located to facilitate operations for its

intended use and for its cleaning and maintenance. Equipment used in the

compounding of drug preparations shall be of suitable composition so that

surfaces that contact components, in-process materials, or drug preparations shall

not be reactive, additive, or absorptive so as to alter the safety, identity, strength,

quality, or purity of the drug preparation beyond that desired.

(b) Equipment and utensils used for compounding shall be cleaned and sanitized

immediately prior to use to prevent contamination that would alter the safety,

identity, strength, quality, or purity of the drug preparation beyond that desired. In

the case of equipment, utensils, and containers/closures used in the compounding

of sterile drug preparations, cleaning, sterilization, and maintenance procedures as

set forth in Board Rules.

(c) Equipment and utensils used for compounding drugs must be stored in a manner to

protect them from contamination. Immediately prior to the initiation of

compounding operations, they must be inspected by the pharmacist and

determined to be suitable for use.

(d) Automatic, mechanical, electronic, or other types of equipment other than

commercial scale manufacturing or testing equipment, may be used in the

compounding of drug preparations. If such equipment is used, it shall be routinely

inspected, calibrated (if necessary), or checked to ensure proper performance.

(3) Physical requirements for pharmacies compounding sterile parenteral preparations.

(a) A pharmacy compounding or preparing sterile parenteral preparations shall have a

designated area for preparing compounded, sterile parenteral preparations as

defined in USP 797. This area shall be physically separate from other areas and

should be designed to avoid unnecessary traffic and airflow disturbances. It shall

be used only for the preparation of sterile parental preparations.

(b) Equipment and supplies for compounding sterile parenteral preparations. A

pharmacy compounding sterile parenteral preparations shall have the following

minimum equipment and supplies:

1. Laminar airflow hood (ISO 5) located within a clean room, or barrier

isolator as described in USP 797;

2. Infusion pumps, if appropriate;

3. Sink, in working condition, with hot and cold running water, which is

convenient to the compounding area for the purpose of hand scrubs prior to

compounding;

4. Facility for light/dark field examination;

5. Appropriate disposal containers for used needles, syringes, etc., and if

applicable, cytotoxic waste from the preparation of chemotherapy agents;

6. A Class II, vertical flow biological safety cabinet or appropriate barrier

isolator, if chemotherapy agents are routinely prepared;

7. Refrigerator/freezer in working condition;

8. If compounding onsite using components which must be weighed, Class A

Balance with an assortment of metric weights or a Class I or II Electronic

Balance;

9. Disposable needles, syringes and other supplies needed for aseptic

admixture;

10. Disinfectant cleaning solutions;

11. Handwashing agent with bactericidal action;

12. Disposable, lint free towels or an automatic hand dryer;

13. Appropriate filters and filtration equipment;

14. Disposable masks and sterile, disposable gloves, gowns, hair and shoe

covers and goggles when indicated;

15. An oncology drug spill kit, if chemotherapy agents are routinely prepared.

16. For the purpose of emergency or immediate patient care, compounded

sterile preparations are exempted from the requirements as outlined in USP

797.

(4) Minimum equipment for pharmacies compounding non-sterile preparations.

(a) A compounding pharmacy must have all equipment required of a pharmacy in

Chapter 480-10 of the Board Rules.

(b) Additionally, a compounding pharmacy must have the appropriate equipment for

use in compounding as defined in USP Chapters 795 and 797.

(5) References. In addition to references required of a pharmacy, pharmacies compounding

sterile pharmaceuticals shall also have a current edition of or electronic access to an

established reference on IV stability and incompatibility, such as, Handbook on Injectable

Drugs or King's Guide to Parenteral Admixtures, current Federal requirements for sterile

compounding and other reference material including but not limited to:

(a) "USP Pharmacists Pharmacopeia",

(6) Variances.

(a) The pharmacist-in-charge may submit to the Georgia State Board of Pharmacy a

typed request for a variance to the provisions relating to minimum equipment

requirements. The reasons for the request for a variance must be included in the

submitted request. A variance shall be granted by the Board only when, in the

judgment of the Board, there are sound reasons for doing so that relate to the

necessary or efficient delivery of health care. After consideration by the Board, the

requestor will be notified of the Board's decision in writing.

(b) If approved, said letter(s) will serve as proof of the Board's approval for the

variance indicated in the letter, and must be posted next to the inspection report.