§ 60.56a Standards for municipal waste combustor operating practices.

FederalRegulations

Ask Donna

How this section applies to your facts.

Title 40 CFR: Protection of Environment › Chapter I › Part 60 › Subpart Ea › § 60.56a: § 60.56a Standards for municipal waste combustor operating practices.

This text was captured on Aug 14, 2026. It is a snapshot, not a live feed, so check the official code before relying on it.

Text

(a) On and after the date on which the initial compliance test is completed or is required to be completed under § 60.8, no owner or operator of an affected facility located within a large MWC plant shall cause such facility to exceed the carbon monoxide standards shown in table 1. Table 1—MWC Operating Standards MWC technology Carbon monoxide emission limit (parts per million by volume) 1 Mass burn waterwall 100 Mass burn refractory 100 Mass burn rotary waterwall 100 Modular starved air 50 Modular excess air 50 RDF stoker 150 Bubbling fluidized bed combustor 100 Circulating fluidized bed combustor 100 Pulverized coal/RDF mixed fuel-fired combustor 150 Spreader stoker coal/RDF mixed fuel-fird combustor 150 1 Measured at the combustor outlet in conjunction with a measurement of oxygen concentration, corrected to 7 percent oxygen (dry basis). The averaging times are specified in § 60.58a(h). (b) No owner or operator of an affected facility located within a large MWC plant shall cause such facility to operate at a load level greater than 110 percent of the maximum demonstrated MWC unit load as defined in § 60.51a. The averaging time is specified under § 60.58a(h). (c) No owner or operator of an affected facility located within a large MWC plant shall cause such facility to operate at a temperature, measured at the final particulate matter control device inlet, exceeding 17 °Centigrade (30 °Fahrenheit) above the maximum demonstrated particulate matter control device temperature as defined in § 60.51a. The averaging time is specified under § 60.58a(h). (d) Within 24 months from the date of start-up of an affected facility or before February 11, 1993, whichever is later, each chief facility operator and shift supervisor of an affected facility located within a large MWC plant shall obtain and keep current either a provisional or operator certification in accordance with ASME QRO-1-1994 (incorporated by reference, see § 60.17) or an equivalent State-approved certification program

e of start-up of an affected facility or before February 11, 1993, whichever is later, each chief facility operator and shift supervisor of an affected facility located within a large MWC plant shall obtain and keep current either a provisional or operator certification in accordance with ASME QRO-1-1994 (incorporated by reference, see § 60.17) or an equivalent State-approved certification program. (e) No owner or operator of an affected facility shall allow such affected facility located at a large MWC plant to operate at any time without a certified shift supervisor, as provided under paragraph (d) of this section, on duty at the affected facility. This requirement shall take effect 24 months after the date of start-up of the affected facility or on and after February 11, 1993, whichever is later. (f) The owner or operator of an affected facility located within a large MWC plant shall develop and update on a yearly basis a sitespecific operating manual that shall, at a minimum, address the following elements of MWC unit operation: (1) Summary of the applicable standards under this subpart; (2) Description of basic combustion theory applicable to an MWC unit; (3) Procedures for receiving, handling, and feeding MSW; (4) MWC unit start-up, shutdown, and malfunction procedures; (5) Procedures for maintaining proper combustion air supply levels; (6) Procedures for operating the MWC unit within the standards established under this subpart; (7) Procedures for responding to periodic upset or off-specification conditions; (8) Procedures for minimizing particulate matter carryover; (9) [Reserved] (10) Procedures for handling ash; (11) Procedures for monitoring MWC unit emissions; and (12) Reporting and recordkeeping procedures

r supply levels; (6) Procedures for operating the MWC unit within the standards established under this subpart; (7) Procedures for responding to periodic upset or off-specification conditions; (8) Procedures for minimizing particulate matter carryover; (9) [Reserved] (10) Procedures for handling ash; (11) Procedures for monitoring MWC unit emissions; and (12) Reporting and recordkeeping procedures. (g) The owner or operator of an affected facility located within a large MWC plant shall establish a program for reviewing the operating manual annually with each person who has responsibilities affecting the operation of an affected facility including, but not limited to, chief facility operators, shift supervisors, control room operators, ash handlers, maintenance personnel, and crane/load handlers. (h) The initial review of the operating manual, as specified under paragraph (g) of this section, shall be conducted prior to assumption of responsibilities affecting MWC unit operation by any person required to undergo training under paragraph (g) of this section. Subsequent reviews of the manual shall be carried out annually by each such person. (i) The operating manual shall be kept in a readily accessible location for all persons required to undergo training under paragraph (g) of this section. The operating manual and records of training shall be available for inspection by EPA or its delegated enforcement agent upon request. (j)-(k) [Reserved] [56 FR 5507, Feb. 11, 1991, as amended at 60 FR 65386, Dec. 19, 1995]

This is a copy of a public record, reproduced as it was published. It is not legal advice, and it may not be the version a court would rely on. Check the official source before you cite it.

A word about cookies

We need a few to keep you signed in and the library working. The rest help us see which pages people use and where they get stuck. They stay off unless you say yes.

§ 60.56a Standards for municipal waste combustor operating practices. · 40 C.F.R. § 60.56a (2026) | Frix