S.C. Code Regs. 8-1219. IRC Section R326.3 Story above grade plane
South CarolinaRegulations
Ask Donna
How this section applies to your facts.
South Carolina Code of Regulations › Chapter 8 BUILDING CODES COUNCIL › S.C. Code Regs. 8-1219
Text
A habitable attic shall be considered a story above grade plane.
Exceptions: A habitable attic shall not be considered to be a story above grade plane provided that the habitable attic meets all the following:
1. The aggregate area of the habitable attic is not greater than three-fourths of the floor area of the story below.
2. The occupiable space is enclosed by the roof assembly above, knee walls, if applicable, on the sides and the floor-ceiling assembly below.
3. The floor of the habitable attic does not extend beyond the exterior walls of the story below.
4. Where a habitable attic is located above a third story, the dwelling unit or townhouse unit shall be equipped with a fire sprinkler system in accordance with Section P2904.
This is a copy of a public record, reproduced as it was published. It is not legal advice, and it may not be the version a court would rely on. Check the official source before you cite it.