FOREST COUNTY POTAWATOMI COMMUNITY (2023)
Tribal code
Ask Donna
What actually matters in this document.
Text
FOREST COUNTY POTAWATOMI COMMUNITY
RESIDENTIAL BUILDING CODE
§ 1.
General
1.1.
Purpose
The purpose of this Code is to establish uniform construction standards and inspection procedures
for one- and two-family Dwellings on Tribal Lands. The provisions of this Code apply to all of the
following:
(a) All one- and two-family Dwellings built or Structurally Altered after the effective date
of this Code;
(b) All Garages, Carports, Porches, stoops, Decks, Balconies, Stairways, and similar
structures, that were constructed or had a production date after the effective date of this
Code, and that are Attached to any Dwelling.
(c) Adjacent, unattached structures listed in this Code that serve as an Exit from a
Dwelling.
1.2.
Authority
The Forest County Potawatomi Community General Council enacts this Ordinance pursuant to its
authority granted under the Forest County Potawatomi Community Tribal Constitution, Article
IV, §1(d).
1.3.
Effective Date and Title
This Ordinance is hereby adopted immediately following the majority approval from the Forest
County Potawatomi Community General Council and it shall be known as the Forest County
Potawatomi Community Residential Building Code.
1.4.
Sovereign Immunity
The Tribe, by adoption of this Ordinance, does not waive its sovereign immunity in any respect.
Any Person acting under good faith of this Ordinance shall be immune from any civil liability
arising out of such actions.
1.5.
Amendment or Repeal
This Ordinance may be amended or repealed by a majority vote of the Forest County Potawatomi
Community General Council. Due to the extensive nature of this Code, the Public Works Division
{00977912.1}
may propose technical amendments to Executive Council on an annual basis. Such technical
amendments may only correct clear errors in the Code. All nontechnical amendments must be
approved by the General Council.
1.6
Jurisdiction
The Forest County Potawatomi Community Tribal Court shall have original jurisdiction over all
proceedings under this Ordinance.
1.7
Interpretation
The Forest County Potawatomi Community Tribal Court shall defer to the Public Works
Division’s reasonable interpretation of this Ordinance, including the amount of any fine imposed
or corrective action taken. The Court shall follow an “Abuse of Discretion” standard in any review
of the Division’s interpretation or action.
Legislative History for Forest County Potawatomi Community Residential Building Code:
Recommended by the Ordinance Department ............................................... (4/17/2023)
Approved by Executive Council ..................................................................... (5/8/2023)
{00977912.1}
Approved by General Council ........................................................................ (5/13/2023)
{00977912.1}
Forest County Potawatomi Community
Code requirements in addition to WI UDC
The provisions on this list shall supersede any conflicting language in the UDC or
this Code.
l.
Attic/ceiling insulation must achieve at minimum R-49.
2.
Exterior wall insulation must achieve at minimum R-21.
3.
Increase minimum stair headroom to 80".
4.
Increase roof live load to 50 lbs/sq.ft.
5.
Spray application of closed cell polystyrene for air sealing in box sills, new exterior wall
construction, and above wall to proper vent is required.
Heat Recovery Ventilator {HRV} or Energy Recovery Ventilator {ERV} for proper air exchange is
6.
mandatory in all new construction.
10" minimum tread depth and 7-3/4" maximum tread rise for conventional stairways.
7.
8.
Any new or replacement atmospheric vent water heaters and furnaces are not allowed.
9.
Contractor is responsible for installing all radon control methods identified by the Department.
See International Residential Code (IRC} Appendix F, Radon Control Methods. APPENDIX F
RADON CONTROL METHODS. 2018 International Residential Code (IRC) I ICC Digital Codes
(iccsafe.org)
10. Any full height basement constructed after the adoption of this Code shall have at least two
means of egress.
11. Exhaust Discharge, domestic cooking exhaust equipment shall discharge to the outdoors
through a duct. The duct shall have a smooth interior surface, shall be airtight, shall be equipped
with a backdraft damper, and shall be independent of all other exhaust systems.
12. Erosion Mat needs to be made of natural fiber {Urban Class I}.
13. All use of polymers for sediment control in waters must be approved by Land and Natural
Resources Division.
14. All construction site erosion control seed selection must be approved by Land and Natural
Resources Division.
15. Contractor shall be responsible for removing all silt fence when notified by the Department that
vegetation has been established or be subject to civil forfeiture.
16. Setback encumbrances. (see chart}
Code Comparison •POWTS Code S"tback Encumbrances (ft)
Horizontal Separation
Soll Absorption System (SAS)
\/ecrtkal S<>pa,atlon
SAS
E(fecU�•·
Date
Gro.und·
11;16,'2,o:n
2/3/10.05
waiter
B.edro.ck
Well
100m
2/3/lO/JS
50\
50{1\
{00969129.6}
Horirontal Separation
Treatment Tanke
Wetlands
Building
lot
line
Swimming
Pool
Water
Service
100
10
5
15
10
Public
w
Main
25"
Well
SO'"
Wetlands
Building
251
1011\
50
s
Line
Lot
Swimming
Pool
Water
Service
1
0
JO
Chapter SPS 320
ADMINISTRATION AND ENFORCEMENT
SPS 320.01
SPS 320.02
SPS 320.03
SPS 320.04
SPS 320.05
Purpose.
Scope.
Effective date.
Applications.
Exemptions.
Subchapter I — Purpose and Scope
Subchapter II — Jurisdiction
SPS 320.06 Procedure for municipalities.
SPS 320.065 State jurisdiction.
SPS 320.07 Definitions.
Subchapter III — Definitions
Subchapter IV — Approval and Inspection of One- and Two-Family Dwellings
SPS 320.08 Wisconsin uniform building permit.
SPS 320.09 Procedure for obtaining a uniform building permit.
SPS 320.10 Inspections.
SPS 320.11 Suspension or revocation of Wisconsin uniform building permit.
Subchapter V — Approval and Inspection of Modular Homes and Their Components
SPS 320.12 Scope. (Intentionally omitted)
SPS 320.13 Manufacture, sale, and Installation of homes.
SPS 320.14 Approval procedures.
SPS 320.15 Effect of approval. (Intentionally omitted)
SPS 320.16 Suspension and revocation of approval. (Intentionally omitted)
SPS 320.17 Effect of suspension and revocation. (Intentionally omitted)
Subchapter VI — Approval of Products
SPS 320.18 Building product approvals.
SPS 320.19
SPS 320.20
SPS 320.21
SPS 320.22
Subchapter VII — Variances, Appeals, Violations and Penalties
Petition for variance.
Municipal variance from the Code. (Intentionally omitted)
Appeals of orders, determinations, and for extension of time.
Penalties and violations.
Subchapter IX — Adoption of Standards
SPS 320.24 Adoption of standards.
Subchapter I — Purpose and Scope
SPS 320.01 Purpose.
(1) The purpose of this Code is to establish uniform construction standards and inspection procedures
for one- and two-family Dwellings on Tribal Lands.
SPS 320.02 Scope.
(1) General. The provisions of this Code apply to all of the following:
(a) All one- and two-family Dwellings built or Structurally Altered after the effective date under
SPS 320.03.
Note: This includes site-built Dwellings, Manufactured buildings used as Dwellings, Modular
Homes and Dwellings that may be designated as cabins, seasonal homes, temporary residences,
etc., (except for Manufactured or HUD homes, which are covered separately under this section).
(g) All Garages, Carports, Porches, stoops, Decks, Balconies, Stairways, and similar structures, that
were constructed or had a production date after the effective date under SPS 320.03, and that are
Attached to any Dwelling.
(h) Adjacent, unattached structures listed under par. (g) that serve as an Exit from a Dwelling.
(6) LANDSCAPING. Except for construction Erosion control, the scope of this Code does not extend to
driveways, sidewalks, landscaping, and other similar features not having an impact on the Dwelling
structure. SPS 320.03 Effective date. The effective date of this ordinance.
SPS 320.04 Applications.
(1) NEW DWELLINGS.
(a) This Code applies to all Dwellings, Dwelling Units, and Foundations for Dwelling Units, for
which the building permit application was made, or construction commenced after the effective
date of this Code.
(b) All Dwellings covered under par. (a) shall meet the requirements of Ch. SPS 321.
1. The Installation of heating, air conditioning, plumbing or electrical systems is not required.
2. If any of the systems under subd. 1. are installed, the systems and their Installation shall
comply with this Code.
3. If a heating or air conditioning system is installed, the Dwelling shall comply with ch. SPS
322.
(2) ADDITIONS AND ALTERATIONS. Additions and Alteration s to Dwellings covered by this Code shall
comply with all provisions of this Code at the time of permit application or the beginning of the project
if no permit is required.
(4) CHANGE OF USE. A building previously used for another purpose, such as a barn or Garage, shall
comply with this Code upon conversion to residential use.
(5) REUSE OF A DWELLING OR FOUNDATION.
(a) Existing Dwelling or Manufactured Home placed on a different Foundation. Where an
existing Dwelling or Manufactured Home is placed on a different Foundation, the new Foundation
is considered an Addition or Alteration to the existing Dwelling or Manufactured Home.
Note: The applicability of this Code to an Addition or Alteration to an existing Dwelling or
Manufactured Home is determined by the original date of construction of the Dwelling or
Manufactured Home and is not altered by any movement of the structure.
(b) New Dwelling or Manufactured Home. A new Dwelling or Manufactured Home placed on a
new or existing Foundation shall meet the permitting, construction and inspection requirements of
a new Dwelling or Manufactured Home.
(6) SEPARATED BUILDINGS. For a building to be considered a separate single-family Dwelling or a
separate 2-family Dwelling within the scope of this Code, regardless of ownership or occupancy
arrangements, all of the following conditions shall be met:
(a) No structural members other than a common footing may be shared between any 2 Dwellings.
Note: Two separated, insulated Foundation walls may share the same structural footing.
(b) The adjoining exterior walls of the separate Dwellings shall each have exterior coverings
meeting the requirements of SPS 321.24.
(c) The adjoining exterior walls, including Foundations, of the separate Dwellings shall each meet
the energy requirements under ch. SPS 322, irrespective of any adjacent Dwelling.
(d) Both sides of any 2 adjoining walls, floors, ceilings and Attics between Dwellings shall meet
the Dwelling separation requirements of SPS 321.08 (1) for 2 Dwellings on the same property less
than 5 feet apart.
Note: 1. Flashing is acceptable to connect the roofs between Dwelling Units. See Ch. SPS 325
Appendix A for further information.
SPS 320.05 Exemptions.
(1) EXISTING DWELLINGS. The provisions of this Code shall not apply to Dwellings and Dwelling
Units, or to Additions or Alterations to such Dwellings, the construction of which was commenced prior
to the effective date of this Code.
(3) REPAIRS. The provisions of this Code do not apply to Repairs or maintenance to Dwellings or
Dwelling Units, or to the Repair of electrical, plumbing, heating, Ventilating, air conditioning and other
systems installed therein.
(4) ACCESSORY BUILDINGS. With the exception of SPS 321.08 (1), the provisions of this Code do not
apply to detached Garages or to any Accessory Buildings detached from the Dwelling.
(5) DETACHED DECKS. The provisions of this Code do not apply to detached Decks provided the Deck
does not serve an Exit from the Dwelling.
(6) FARM BUILDINGS. The provisions of this Code do not apply to the buildings used exclusively for
farm operations and not for human habitation.
Subchapter III — Definitions
SPS 320.07 Definitions. In chs. SPS 320 to 325:
(1) “Accessory Building" means a Detached Building, not used as a Dwelling Unit but is incidental to
that of the main building and which is located on the same lot. Accessory Building does not mean farm
building.
(2) “Addition" means new construction performed on a Dwelling which increases the outside
dimensions of the Dwelling.
(3) “Allowable Stress" means the specified maximum permissible Stress of a material expressed in
load per unit area.
(4) “Alteration" means an enhancement, upgrade or substantial change or modification other than an
Addition or Repair to a Dwelling or to electrical, plumbing, heating, Ventilating, air conditioning and
other systems within a Dwelling.
(5) “Approved" means an approval by the Public Works Division. (Approval is not to be construed as
an assumption of any legal responsibility for the design or construction of the Dwelling or Building
Component).
(5m) “Attached" defining the relationship between another building and a Dwelling, means at least
one of the following conditions is present:
(a) There is a continuous, weatherproof roof between the two structures.
Note: The sides are not required to be enclosed with walls.
(b) There is a continuous, structural floor system between the two structures.
(c) There is a continuous Foundation system between the two structures.
(6) “Attic" means a space under the roof and above the ceiling of the topmost part of a Dwelling.
(6a) “Authorized Inspector " (previously “Certified Inspector” means a person authorized by the
Public Works Division to engage in the administration and enforcement of this Code.
(7) A “Balcony" is a landing or Porch projecting from the wall of a building.
(7m) “Base Flood Elevation" means the depth or peak elevation of flooding, including wave height,
which has a one percent or greater chance of occurring in any given year.
(8) “Basement" means that portion of a Dwelling below the First Floor or Ground Floor with its entire
floor below grade.
(8m) “Best Management Practices" means practices, techniques, or measures that the Department
determines to be effective means of preventing or reducing pollutants of surface water generated from
construction sites.
(9) “Building Component" means any subsystem, subassembly or other system designed for use in or
as part of a structure, which may include structural, electrical, mechanical, plumbing and fire protection
systems and other systems affecting health and safety.
(10) “Building System" means plans, specifications and documentation for a system of Manufactured
building or for a type or a system of Building Components, which may include structural, electrical,
mechanical, plumbing and variations which are submitted as part of the Building System.
(10m) “Business Day" means any day the Public Works Division is open for business.
(10t) “Carport" means a structure used for storing motorized vehicles that is Attached to a Dwelling
and that has at least 2 sides completely unenclosed.
(11) “Ceiling Height" means the clear vertical distance from the finished floor to the finished ceiling.
(12m) “Ch. SPS 325 Appendix" means chs. SPS 320 to 325 Appendix.
(13) “Chimney" is one or more vertical, or nearly so, passageways or flues for the purpose of conveying
flue gases to the atmosphere.
(14) “Chimney Connector" Same as smoke pipe.
(15) “Closed Construction" means any building, Building Component, assembly, or system
Manufactured in such a manner that it cannot be inspected before Installation at the building site without
disassembly, damage, or destruction.
(15g) “Coarse Aggregate" means granular material, such as gravel or crushed stone, that is
predominately retained on a sieve with square openings of 4.75 mm or 0.18 inch.
(15m) “Coastal Floodplain" means an area along the coast of Lake Michigan or Lake Superior below
Base Flood Elevation that is subject to wave runup or wave heights of 3 feet or more.
(16) “Code" means the Forest County Potawatomi Community Residential Building Code.
(17) “Combustion Air” means the total amount of air necessary for the complete combustion of a fuel.
(18) “Common Use Area” means Kitchens, hallways, Basements, Garages, and all Habitable Rooms.
Note: These areas must meet the circulation requirements under SPS 321.035.
(19) “Compliance Assurance Program” means the detailed system documentation and methods of
assuring that Manufactured Dwellings and Dwelling components are Manufactured, stored, transported,
assembled, handled, and installed in accordance with this Code.
(19m) “Composting Toilet System” means a method that collects, stores, and converts by bacterial
digestion nonliquid-carried human wastes or organic Kitchen wastes, or both, into humus.
(19r) “Control Practice" means a method or device implemented to prevent or reduce Erosion or the
resulting deposition of soil or sediment.
(20) “Cooling Load" is the rate at which heat must be removed from the space to maintain a selected
indoor air temperature during periods of design outdoor weather conditions.
(21) “Dead Load" means the vertical load due to all permanent structural and nonstructural
components of the building such as joists, rafters, sheathing, finishes and construction assemblies such
as walls, partitions, floors, ceilings and roofs, and systems.
(21m) “Deck" means an unenclosed exterior structure, attached or adjacent to the exterior wall of a
building, which has a floor, but no roof.
(23) “Department" for the purposes of this Code, means the FCPC Public Works Division.
(24) “Detached Building " means any building which is not physically connected to the Dwelling.
(24m) “Dilution Air" means air that is provided for the purpose of mixing with flue gases in a draft
hood or draft regulator.
(24r) “Direct-Vent Appliance" means a gas-burning appliance that is constructed and installed so that
all air for combustion is derived directly from the outside atmosphere and all flue gases are discharged
to the outside atmosphere.
(xx) “Division” means a unit of Tribal government that reports directly to the Executive Council.
(25) “Dwelling" means any building, the Initial Construction of which is commenced on or after the
effective date of this Code, which contains one or 2 Dwelling Units.
(26) “Dwelling Contractor" means any person, firm or corporation engaged in the business of
performing Erosion control or construction work such as framing, roofing, siding, insulating, masonry,
or Window replacement work covered under this Code and who takes out a building permit. “Dwelling
Contractor" does not include the Owner of an existing Dwelling, an Owner who will reside in a new
Dwelling or a person, firm or corporation engaging exclusively in electrical, plumbing, or heating,
ventilating and air conditioning work.
(27) “Dwelling Unit" means a structure, or that part of a structure, which is used or intended to be used
as a home, residence or sleeping place by one person or by 2 or more persons maintaining a common
household, to the exclusion of all others.
(28t) “Erosion" means the detachment and movement of soil, sediment or rock fragments by water,
wind, ice, or gravity.
(29) “Exit" means a direct, continuous, unobstructed means of egress from inside the Dwelling to the
exterior of the Dwelling.
(33m) “Fire Blocking" means a material or device used to retard or prevent the spread of flame or hot
gases through concealed spaces into adjacent rooms or areas.
(34) “Firebox" means that part of the fireplace used as the combustion chamber.
(34e) “First Floor" means the first-floor level above any Ground Floor or Basement or, in the absence
of a Ground Floor or Basement, means the lowest floor level in the Dwelling.
(34f) “Flight" means a continuous series of risers and treads, with no intermediate Landings.
(34g) “Flood Fringe Area" means that portion of the Floodplain outside of the Floodway that is at or
below Base Flood Elevation. The term “flood fringe" is intended to designate an area of standing, rather
than flowing, water.
(34h) “Floodplain" means land which is subject to flooding which is at or below Base Flood Elevation.
The Floodplain includes the Floodway and Flood Fringe Areas.
(34i) “Floodway" means the channel of a river or stream and those portions of the Floodplain adjoining
the channel required to carry the flood discharge. The term “Floodway" is intended to designate an area
of flowing, rather than standing, water.
(34s) “Foundation" means the structural system used to transfer the weight of the building to the earth.
Note: The Foundation may include one or more components such as footings, piers, columns, slabs,
and walls.
(35) “Garage" means a structure used for storing motorized vehicles that has any more than 2 sides
completely enclosed.
(36) “Gas Appliance" means any device that uses gas as a fuel or raw material to produce light, heat,
power, refrigeration, or air conditioning.
(36m) “Ground Floor" means that level of a Dwelling, below the First Floor, located on a site with a
sloping or multilevel grade and which has a portion of its floor line at grade.
(36r) “Guard" means a barrier erected to prevent a person from falling to a lower level.
(37) “Habitable Room" means any room used for sleeping, living, or dining purposes, excluding such
enclosed places as Kitchens, closets, pantries, bath or toilet rooms, hallways, laundries, storage spaces,
utility rooms, and similar spaces.
(37m) “Handrail" means a horizontal or sloping rail intended for grasping by a hand, for guidance or
support or preventing a fall down a Stair.
(38) “Hearth" means the floor area within the fire chamber of a fireplace.
(38m) “Hearth Extension" means the surfacing applied to the floor area extending in front of and at
the sides of the fireplace opening.
(40) “Heating Load" is the estimated heat loss of each room or space to be heated, based on
maintaining a selected indoor air temperature during periods of design outdoor weather conditions. The
total heat load includes: the transmission losses of heat transmitted through the wall, floor, ceiling, glass,
or other surfaces; and either the infiltration losses or heat required to warm outdoor air used for
ventilation.
Note: Infiltration losses include heat required to warm outside air which leaks through cracks and
crevices, around doors and Windows or through open doors and Windows.
(40m) “Hollow Unit" means a masonry unit which has a net cross-sectional area parallel to the bearing
face which is less than 75% of the gross cross-sectional area.
(40t) “Incinerating Toilet" means a self-contained device for the treatment of nonliquid carried wastes
that deposits the wastes directly into a combustion chamber, reduces the solid portion to ash and
evaporates the liquid portion.
(41) “Independent Inspection Agency" means any person, firm, association, partnership, or
corporation certified by the Department to perform certified inspections under this Code.
(42) “Initial Construction" means the date of issuance of the building permit.
(44) “Installation" means the assembly of a Manufactured building on site and the process of affixing
a Manufactured building to land, a Foundation, footing or an existing building.
(46) “Kitchen" means an area used, or designed to be used, for the preparation of food.
(46m) “Land Disturbing Construction Activity" means any man-made alteration of the land surface
resulting in a change in the topography or existing vegetative or non-vegetative soil cover, that may
result in storm water runoff and lead to an increase in soil Erosion and movement of sediment. Land
Disturbing Construction Activity includes clearing and grubbing, demolition, excavating, pit or trench
dewatering, filling, and grading activities.
(47) “Landing" means the level portion of a Stairs located between Flights of Stairs or located at the
top and base of a Stairs.
(48) “Listed and Listing" means equipment or Building Components which are tested by an
independent testing agency and accepted by the Department.
(49) “Live Load" means the weight superimposed on the floors, roof, and structural and nonstructural
components of the Dwelling through use and by snow, ice, or rain.
(50) “Loft" means an upper room or floor which has at least 50% of the common wall open to the floor
below. The opening may be infringed upon by an open Guard constructed in compliance with SPS
321.04 (2), but not by a Window or half-wall Guard. All Habitable Rooms of Lofts are open to the floor
below.
(51) “Manufacture" means the process of making, fabricating, constructing, forming, or assembling a
product from raw, unfinished, semifinished, or finished materials.
(52m) “Manufactured Home" means any of the following:
(am) A structure that is designed to be used as a Dwelling with a permanent Foundation and that is
certified by the federal Department of Housing and Urban Development as complying with the
standards established under 42 USC 5401 to 5425.
(c) A Mobile Home unless a Mobile Home is specifically excluded under the applicable statute.
(53a) “Mobile Home" means a vehicle Manufactured or assembled before June 15, 1976, designed to
be towed as a single unit or in sections upon a highway by a motor vehicle and equipped and used, or
intended to be used, primarily for human habitation, with walls of rigid un-collapsible construction,
which has an overall length in excess of 45 feet. `Mobile Home' includes the Mobile Home structure, its
plumbing, heating, air conditioning and electrical systems, and all appliances and all other equipment
carrying a Manufacturer's warranty."
(53) “Mechanical Drat Venting System" means a Venting system for a gas burning appliance that is
designed to remove flue or Vent gases by mechanical means, such as a fan, which may consist of an
induced draft portion under non-positive static pressure or a forced draft portion under positive static
pressure.
(53f) “Modular Home" means any structure or component thereof which is intended for use as a
Dwelling and:
a. Is of Closed Construction and fabricated or assembled on-site or off-site in manufacturing
facilities for Installation, connection, or assembly and Installation, at the building site; or
b. Is a building of Open Construction which is made or assembled in manufacturing facilities away
from the building site for Installation, connection, or assembly and Installation, on the building site
and for which certification is sought by the Manufacturer.
(53m) “Multiple Station Smoke Alarm" means an assembly that incorporates the smoke detector, the
control equipment, and the alarm-sounding device in one unit that is capable of being interconnected
with one or more additional alarms so that the actuation of one alarm causes the operation of all
interconnected alarms.
(54) “Multi-Wythe Wall" is a masonry wall composed of 2 or more wythes of masonry units tied or
bonded together.
(55m) “Naturally Vented Appliance" means an appliance with a Venting system designed to remove
flue or Vent gases under non-positive static Vent pressure entirely by natural draft.
(56) “Open Construction" means any building, Building Component, assembly, or system
Manufactured in such a manner that it can be readily inspected at the building site without disassembly,
damage, or destruction.
(57) “Owner" means any person having a legal or equitable interest in the Dwelling.
(58) “Perm" means a unit of permeance which is measured in grains per (hour) (square foot) (inch of
mercury vapor pressure difference).
Note: The lower the Perm rating of a material is, the more difficult it is for water vapor to pass
through it.
(59) “Pilaster" is a projection of masonry or a filled cell area of masonry for the purpose of bearing
concentrated loads or to stiffen the wall against lateral forces.
(59m) “Porch" means an unenclosed exterior structure at or near grade attached or adjacent to the
exterior wall of any building and having a roof and floor.
(59t) “Privy" means an enclosed nonportable toilet into which non-water-carried human wastes are
deposited to a subsurface storage chamber.
(61) “Repair" means the act or process of restoring to original soundness, including redecorating,
refinishing, nonstructural Repairs or maintenance, or the replacement of existing fixtures, systems or
equipment with the equivalent fixture, system, or equipment.
(62) “Shingle" means a unit of roof-covering material that has been Manufactured to specific
dimensions and is applied in overlapping fashion. “Shingle" includes all of the following:
(a) “Fiberglass Asphalt Shingle" means a type of Shingle with an internal mat composed of
nonwoven, resin-bonded glass fibers, that is impregnated and coated with asphalt.
(b) “Laminated Shingle" means a Shingle with a second layer of asphalt and mat laminated to the
first layer, usually in a design pattern to simulate the dimensional appearance of natural slate or
wood shakes.
(c) “Organic Asphalt Shingle" means a Shingle with an internal mat composed of organic fibers,
such as cellulose, that is saturated and coated with asphalt.
(d) “Strip Shingle" means a rectangular Shingle that relies either on a sealant or on a combination
of weight and stiffness to resist wind uplift, rather than using interlocking tabs.
(63) A “Single-Wythe Wall" is a masonry wall consisting of one unit of thickness.
(64) A “Smoke Chamber" is that part of a fireplace which acts as a funnel to compress the smoke and
gases from the fire so that they will enter the Chimney above.
(65) A “smoke pipe" is a connector between the solid or liquid fuel-burning appliance and the
Chimney.
(65m) “Solid Unit" means a masonry unit which has a net cross-sectional area parallel to the bearing
face which is 75% or more of the gross cross-sectional area.
(65r) “Stabilized" means the condition where vegetation is established, or other practices are in place
on exposed soil surfaces so as to reduce Erosion.
(66) “Stair," “Stairs," or “Stairway" means one or more risers and the necessary treads, which form
a continuous passage from one elevation to another. Multiple Stairways can be connected by platforms
and Landings.
(68) A “Story" is that portion of a building located above the Basement, between the floor and the
ceiling.
(69) A “Stove" is a nonportable solid-fuel-burning, Vented, non-ducted heat-producing appliance
located in the space that it is intended to heat. This definition does not include cooking appliances.
(70) “Stovepipe" Same as smoke pipe.
(71) “Strain" means a change in the physical shape of a material caused by Stress.
(72) “Stress" means internal resistance to an external force expressed in load per unit area; Stresses
acting perpendicular (compression or tension) to the surface, shear Stresses acting in the plane of the
surface or bending Stresses which cause curving.
(73) “Structurally Altered” means any change to a supporting member of a building including
Foundations, bearing walls, or partitions, columns, beams, girders, or any structural change in the roof
or exterior wall.
(74) “Structural Analysis" is a branch of the physical sciences which uses the principles of mechanics
in analyzing the impact of loads and forces and their effect on the physical properties of materials in the
form of internal Stress and Strain.
(75) The “Throat" of a fireplace is the slot-like opening above the Firebox through which flames,
smoke, and other products of combustion pass into the Smoke Chamber.
(75a) “Tribal Lands” means all lands of the Forest County Potawatomi Community, the legal title to
which is held by the United States of America.
(75m) “UDC" means Wisconsin Uniform Dwelling Code.
(76) “Vent" means a vertical flue or passageway to Vent fuel-burning appliances.
(77) A “Vent Connector" is a connector between a fuel-burning appliance and the Chimney or Vent.
(77f) “Water-Resistive Barrier" means a material, including flashing, behind an exterior wall
covering that is intended to resist liquid water that has penetrated behind the permanent weather-resistant
finish from further intruding into the exterior wall assembly.
(77m) “Waters of the State" includes those portions of Lake Michigan and Lake Superior within the
boundaries of Wisconsin, and all lakes, bays, rivers, streams, springs, ponds, wells, impounding
reservoirs, marshes, watercourses, drainage systems and other surface waters or groundwaters, natural
or artificial, public, or private, within the state or over which the state claims jurisdiction.
(78) “Window" means a glazed opening in an exterior wall, including glazed portions of doors, within
a conditioned space.
Subchapter IV — Approval and Inspection of One- and Two-Family Dwellings
SPS 320.08 Building permit.
(1) (INTENTIONALLY OMITTED)
(2) (INTENTIONALLY OMITTED)
SPS 320.09 Procedure for obtaining uniform building permit.
(1) APPLICATION. Application for a FCPC uniform building permit shall be on forms obtained from
the Public Works Division. No application shall be accepted that does not contain all the information
requested on the form.
(2) FILING OF PERMIT APPLICATIONS.
(a) Construction, Structural Alterations, or Installation of a Dwelling.
1. A building permit application for the construction, Structural Alterations, or Installation of a
Dwelling shall be filed with the Public Works Division.
2. A building permit shall not be required for any Construction, Structural Alterations, or
Installation of a Dwelling performed by employees of the Public Works Division.
4. The building permit shall not be issued prior to the receipt of all completed forms, fees, plans,
and documents required to process the application.
(c) General requirements.
1. The permit application shall be reviewed by an Authorized Inspector.
2. A permit may be issued only after approval of the requirements under this section by an
Authorized Inspector.
3. Dwellings for which a permit has been issued shall be inspected in accordance with SPS
320.10.
(3) FEES.
(a) Executive Council Approval
All fees under this Code will be subject to review and approval by the Executive Council on an
annual basis.
(b) Inspection fees.
1. Standard inspections (identified on the Inspection Checklist) will be provided at no cost to
the Owner. UDC inspection agency fees, if necessary, shall be determined by contract between
the Tribe and the agency, where the agency has been authorized to conduct inspections on behalf
of the Tribe. The cost of repeat, special, or nonstandard inspections shall be borne by the Owner.
(4) PLAN SUBMITTALS. At least 2 sets of plans for all one- and two-family Dwellings shall be submitted
to the Public Works Division for examination and approval at the time the building permit application
is filed.
(5) REQUIRED PLANS. The required building plans shall be legible and drawn to scale or dimensioned
and shall include all of the following:
(a) Site plan. The site plan shall show all of the following:
1. The location of the Dwelling and any other buildings, wells, surface waters and dispersal
systems on the site with respect to property lines and surface waters adjacent to the site.
2. The areas of land-disturbing construction activity and the location of all Erosion and sediment
control measures to be employed in order to comply with SPS 321.125.
3. The pre-construction ground surface slope and direction of runoff flow within the proposed
areas of land disturbance.
(b) Floor plan.
1. Floor plans shall be provided for each floor.
2. The following features shall be included on all floor plans:
a. The size and location of all rooms, doors, Windows, structural features, Exit
passageways and Stairs.
b. The use of each room.
c. The location of plumbing fixtures, Chimneys, heating and cooling appliances, and a
heating distribution layout.
d. The location and construction details of wall bracing on each building side and floor
level. The details may consist of the Wall Bracing Compliance Worksheet or a legend
showing which wall bracing method is used and the lengths or number of braced wall
panels and demarcation of the circumscribed rectangles if more than one is used.
(c) Elevations. The elevations shall show all of the following:
1. The exterior appearance of the building, including the type of exterior materials.
2. The location, size, and configuration of doors, Windows, roof, Chimneys, exterior grade,
footings, and Foundation walls.
(6) REQUIRED DATA.
(a) All plans submitted for approval shall be accompanied by sufficient data, calculations, and
information to determine if the Dwelling will meet the requirements of this Code.
(b) The data and information for determining compliance with the energy conservation standards
shall be submitted in a format Approved by the Public Works Division.
(d) The name of the initial downstream receiving water of the state from the Dwelling shall be
identified, regarding Erosion and sediment control.
(7) MASTER PLANS.
(a) Where a Dwelling is intended to be identically and repetitively constructed at different
locations, a master plan may be submitted for approval.
(b) The plans shall include plans and data as required under subs. (5) and (6).
(c) If the plans conform to the provisions of the Code, an approval and a master plan number shall
be issued.
(d) The number issued may be used in lieu of submitting building plans for each location.
(e) A site plan shall be submitted for each location at the time of application for the building permit.
(8) APPROVAL OF PLANS.
(a) If the Public Works Division determines that the plans submitted for a one- or two-family
Dwelling substantially conform to the provisions of this Code and other legal requirements, an
approval shall be issued.
(b) The plans shall be stamped “conditionally Approved" by an Authorized Inspector who holds
the respective credential for the plans reviewed.
(c) One copy shall be returned to the applicant and one copy shall be retained by the Public Works
Division.
(d) The conditions of approval shall be indicated by a letter or on the permit.
(e) All conditions of the approval shall be met during construction.
(9) ISSUANCE AND POSTING OF PERMITS.
(a) Building permit.
1. The building permit shall be issued if the requirements for filing and fees are satisfied, and
the plans have been conditionally Approved.
3. A person applying for a building permit for work covered under ch. SPS 321 or 322 who is
not the Owner who resides or will reside in the Dwelling shall hold one of the following
credentials:
a. A Dwelling Contractor certification.
b. A Dwelling Contractor — restricted certification.
c. A Dwelling Contractor financial responsibility certification.
d. A Dwelling Contractor financial responsibility — restricted certification.
4. A person applying for a building permit for work covered under ch. SPS 321 or 322 who is
not the Owner who resides or will reside in the Dwelling shall hold or engage, as an employee,
a person who holds a certification issued by the Department as a Dwelling Contractor qualifier.
5. The permit shall expire 24 months after issuance if the Dwelling exterior has not been
completed.
6. The name and license number of the Wisconsin master plumber responsible for the
Installation of plumbing shall be entered on the permit by the Department at the time of issuance.
(c) Private onsite wastewater treatment systems. If the proposed construction requires connection
to a private onsite wastewater treatment system, a building permit may not be issued unless
conformance with SPS 383.25 (2) has first been determined.
Note: See Ch. SPS 325 Appendix A for a reprint of SPS 383.25 (2).
(d) Posting of permit.
1. The Approved building permit shall be posted in a conspicuous place at the Dwelling site.
(10) DISAPPROVAL OF PLANS AND DENIAL OF PERMITS.
(a) General. Approval shall be denied if the Public Works Division determines that the building
permit application or the plans do not substantially conform to the provisions of this Code and other
legal requirements.
(b) Denial of application. A copy of the denied application, accompanied by a written statement
specifying the reasons for denial, shall be sent to the applicant and to the Owner as specified on the
building permit application.
(c) Stamping of plans.
1. Plans which do not substantially conform to the provisions of the Code shall be stamped “not
Approved."
2. One copy shall be returned to the person applying for the building permit and one copy shall
be retained by the Public Works Division.
(d) Appeals. The applicant may appeal a denial of the application in accordance with the procedure
outlined in SPS 320.21.
(11) TIME-SPAN FOR APPROVAL OR DENIAL. Action to approve or deny a building permit application
shall be completed within 10 Business Days of receipt of all forms, fees, plans and documents required
to process the application, and completion of other prerequisite permitting requirements.
SPS 320.10 Inspections.
(1) INSPECTOR CERTIFICATION. All inspections, for the purpose of administering and enforcing this
Code, shall be performed by the Public Works Division or its authorized representative.
(2) GENERAL INSPECTION REQUIREMENTS.
(a) General. Inspections shall be conducted by the Public Works Division or its authorized
representative to determine if the construction or Installations conform to the conditionally
Approved plans, the building permit application, and the provisions of this Code. For each
individual inspection, a separate fee may be charged for any inspection after initial and one
reinspection.
(b) Inspection notice.
1. The applicant or an authorized representative shall request inspections from the Public Works
Division.
2. Construction may not proceed beyond the point of inspection until the inspection has been
completed.
3. Construction may proceed if the inspection has not taken place by the end of the fourth
Business Day following the day of notification or as otherwise agreed between the applicant
and the Public Works Division.
(3) INSPECTION TYPES.
(a) General. The inspections described in pars. (b) to (i) shall be performed to determine if the
work complies with this Code.
(b) Erosion control inspection. Erosion control inspections shall be performed concurrently with
all other required construction inspections. Additional inspections for Erosion control may be
performed by the delegated authority.
(c) Foundation excavation inspection.
1. The excavation for the Foundation shall be inspected after the placement of any forms or
required reinforcement and prior to the placement of the permanent Foundation material.
2. If a drain tile system is required, by the Public Works Division or by groundwater levels in
the excavation, the presence and location of bleeders used to connect the interior and exterior
drain tile shall be inspected at the same time as the excavation.
Note: This excavation inspection may be used to determine the need for drain tile under
SPS 321.17.
(d) Foundation reinforcement inspection. The placement of reinforcement shall be inspected
where the reinforcement is required for Code compliance.
(e) Foundation inspection. The Foundation shall be inspected after completion. Where damp
proofing, exterior insulation or drain tile are required for Code compliance, the Foundation shall
be inspected prior to backfilling.
(f) Rough inspection.
1. A rough inspection shall be performed for each inspection category listed under subd. 1.
a. to e. after the rough work is constructed but before it is concealed.
a. The Basement floor area.
Note: The inspection of the Basement floor area should include the following: any
underfloor plumbing, electrical, or HVAC; any interior drain tile with base course
required under SPS 321.17; the structural base course for the floor slab if required under
SPS 321.20; and the underfloor vapor retarder as required under SPS 322.38.
b. General construction, including framing.
c. Rough electrical.
d. Rough plumbing.
e. Rough heating, Ventilating and air conditioning.
2. All categories of work for rough inspections may be completed before the notice for
inspection is given, provided the work has not been covered.
3. The applicant may request one rough inspection or individual rough inspections.
(g) Insulation inspection. An inspection shall be made of the insulation and vapor retarders after
they are installed but before they are concealed.
(h) Final inspection.
1. The Dwelling may not be occupied until a final inspection has been made that finds no critical
violations of this Code that could reasonably be expected to affect the health or safety of a
person using the Dwelling, and an occupancy permit has been issued.
(i) Installation inspection. An inspection shall be performed on the Installation of a Manufactured
Home or Modular Home.
(4) NOTICE OF COMPLIANCE OR NONCOMPLIANCE.
(a) General.
1. Notice of compliance or noncompliance with this Code shall be written on the building permit
or another readily visible means and posted at the job site. Additionally, the notice may be
delivered electronically if mutually agreed upon by the applicant and inspector.
2. Upon finding noncompliance, the Public Works Division shall also notify the applicant of
record and the Owner, in writing, of the violations to be corrected. Alternatively, the notification
may be delivered electronically if mutually agreed upon by the applicant and inspector.
3. Except as specified under par. (b), the Public Works Division shall order all cited violations
corrected within 5 Business Days after notification, unless an extension of time is granted by
the Public Works Division.
(b) Erosion and sediment control requirements.
1. The time period allowed for compliance with the Erosion and sediment control provisions
under SPS 321.125 shall be determined based on the severity of the noncompliance in relation
to soil loss or potential damage to the Waters of the State.
2. The Land and Natural Resources Division may issue a special order directing an immediate
cessation of construction work on other aspects of the Dwelling until compliance with the
Erosion and sediment control provisions under SPS 321.125 is attained. Construction work may
resume once the Erosion and sediment control compliance corrections are completed.
(5) VOLUNTARY INSPECTION. The Public Works Division or its authorized representative may, at the
request of the Owner or the lawful occupant, enter and inspect Dwellings, subject to the provisions of
this Code, to ascertain compliance with this Code.
SPS 320.11 Suspension or revocation of building permit.
(1) Suspension or Revocation
(a) The Public Works Division may suspend or revoke any building permit where it appears that
the permit or approval was obtained through fraud or deceit, where the applicant has willfully
refused to correct a violation order or where the inspector is denied access to the premises.
(b) No construction may take place on the Dwelling after suspension or revocation of the permit.
(2) Any person aggrieved by a determination made by the Public Works Division may appeal the
decision in accordance with SPS 320.21.
SPS 320.13 Manufacture, sale, and Installation of homes.
(1) MANUFACTURE AND SALE. No Modular Home, Manufactured Building System, or component of
the Building System subject to this part shall be installed on Tribal Lands unless it is Approved by the
Public Works Division and/or meets the requirements of this Code and bears the Wisconsin insignia
issued or a state seal or an insignia reciprocally recognized by the State of Wisconsin.
(2) INSTALLATION. A building permit shall be obtained in compliance with SPS 320.09 (1) to (5)
(a) before any on-site construction falling within the scope of this Code is commenced for a Modular
Home. The permit shall be issued in compliance with SPS 320.09 (9).
SPS 320.14 Approval procedures.
(1) APPLICATION FOR APPROVAL.
(a) An application for approval of any Modular Home, Building System or component shall be
submitted to the Public Works Division in the form required by the Public Works Division, along
with the appropriate fees in compliance with SPS 302.34.
(b) The Public Works Division shall review and make a determination on an application for
approval of a Modular Home, Building System or component within 30 days.
(d) Unit identification. Each Modular Home and major transportable section or component shall
be assigned a serial number prior to delivery to Tribal Lands. The serial number shall be located
on the Manufacturer's data plate.
(e) Manufacturer's data plate. The Manufacturer's data plate for Building Systems shall contain
the following information, where applicable:
1. Manufacturer's name and address;
2. Date of Manufacture;
3. Serial number of unit;
4. Model designation;
5. Identification of type of gas required for appliances and directions for water and drain
connections;
6. Identification of date of the Codes or standards complied with;
7. State insignia number;
8. Design loads;
9. Special conditions or limitations of unit;
10. Electrical ratings; instructions and warnings on voltage, phase, size and connections of units
and grounding requirements.
Subchapter VI — Approval of Products
SPS 320.18 Building product approvals.
(1) VOLUNTARY APPROVAL.
(a) The Owner may voluntarily submit materials, equipment, and products regulated by this Code
to the Public Works Division for a determine whether such materials, equipment, and/or products
comply with the requirements of this Code.
1. Approval of materials, equipment and products shall be based on sufficient data, tests and
other evidence that prove the material, equipment or product is in compliance with the standards
specified in this Code.
2. Tests, compilation of data, and calculations for materials, equipment and products shall be
conducted by a qualified independent third party.
(2) ALTERNATE APPROVAL.
(a) Materials, equipment and products which meet the intent of this Code and which are not
Approved under sub. (1) shall be permitted if Approved in writing by the Public Works Division.
1. Approval of materials, equipment and products shall be based on sufficient data, tests, and
other evidence that proves the material, equipment or product meets the intent of the standards
specified in this Code.
2. Tests, compilation of data, and calculations for materials, equipment and products shall be
conducted by a qualified independent third party.
(3) EXPERIMENTAL APPROVAL.
(a) The Public Works Division may allow use of an experimental material, equipment, or product
for the purpose of proving compliance with the intent of this Code.
(b) The Public Works Division may require the submission of any information deemed necessary
for review.
(c) The Public Works Division may limit the number of applications it will accept for approval of
experimental materials, equipment, or products.
(d) Installations of a material, equipment or product under an experimental approval shall comply
with all of the following:
1. Plans detailing the Installation for each project where the experimental material, equipment
or product is to be used shall be submitted to the Public Works Division.
2. A copy of the experimental approval shall be attached to the submitted plans and Approved
plans.
a. A letter of consent from the Owner of the Installation shall be attached to the submitted
plans and Approved plans.
b. The letter under subd. 3. a. shall acknowledge that the Owner has received and read a
copy of the experimental approval and is in compliance with all conditions of the approval.
4. A person responsible for construction of the project shall be designated in writing by the
Owner.
5. The person designated as responsible for the construction of the project shall, upon
completion of construction, certify in writing to the Public Works Division that the Installation
is in compliance with the experimental approval, Approved plans, specifications, and data.
(e)
1. Any onsite inspections shall be performed by the Public Works Division, or other person
authorized by the Public Works Division, at time intervals as specified by the Public Works
Division, but not less than once a year. The inspector shall write an inspection report.
2. The Public Works Division may assess a fee for each inspection conducted under subd. 1.
(f) Five years and 6 months after the date of the completed Installation, the Public Works Division
shall order the removal of the experimental material, equipment, or product, or issue an approval
for the material, equipment, or product.
(4) REVIEW, APPROVAL, AND REVOCATION PROCESSES.
(a)
(b)
1. Upon receipt of a fee and a written request, the Public Works Division may issue an approval
for a material, equipment, or product.
2. The Public Works Division shall review and make a determination on an application for
approval after receipt of all forms, fees, plans, and information required to complete the review.
3. For voluntary and alternate approvals, a determination shall be made within 40 Business Day
s of receipt of all required materials.
4. For an experimental approval, a determination shall be made within 6 months of receipt of
all required materials.
1. The Public Works Division may include specific conditions in issuing an approval, including
an expiration date for the approval.
2. Violations of the conditions under which an approval is issued shall constitute a violation of
this Code.
(c) If the Public Works Division determines that the material, equipment, or product does not
comply with this Code or the intent of this Code, or that an experimental approval will not be
issued, the request for approval shall be denied in writing.
(e)
1. The Public Works Division may revoke or deny an approval of a material, equipment or
product for any false statements or misrepresentations of relevant facts or data, unacceptability
of a third-party providing information, or as a result of material, equipment, or product failure.
2. The Public Works Division may re-examine an Approved material, equipment or product and
issue a revised approval at any time.
(g) An approval issued by the Public Works Division may not be construed as an assumption of
any responsibility for defects in design, construction or performance of the Approved material,
equipment, or product nor for any damages that may result.
(h) Fees for the review of a material, equipment or product under this section and any onsite
inspections shall be submitted in accordance with the fee schedule contained in this Code.
(5) UNGRADED OR USED MATERIALS.
(a) Ungraded or used building materials may be used or reused as long as the material possesses
the essential properties necessary to achieve the level of performance required by the Code for the
intended use.
(b) The Public Works Division may require tests in accordance with sub. (1) or (2) at the Owner’s
expense as a condition of approval.
Subchapter VII — Variances, Appeals, Violations and Penalties
SPS 320.19 Petition for variance. The Public Works Division may grant a variance to a rule only if the
variance does not result in lowering the level of health, safety and welfare established or intended by the
rule.
(1) APPLICATION FOR VARIANCE. The applicant shall submit the petition for variance application to
the Public Works Division. The following items shall be submitted when requesting a variance:
(a) A clear written statement of the specific provisions of this Code from which a variance is
requested and the method of establishing equivalency to those provisions.
Note: A copy of the Petition for Variance is available upon request from the Public Works Division.
SPS 320.21 Appeals of orders, determinations, and for extension of time.
(2) APPEALS OF ORDERS AND DETERMINATIONS BY THE DEPARTMENT. Appeals of an order of the
Public Works Division, including denials of application for permits, shall be made to the Public Works
Division. The Public Works Division shall review and make a determination on an appeal within 60
Business Day s of receipt of all calculations and documents necessary to complete the review.
(3) EXTENSIONS OF TIME.
(a) The time for correction of cited orders as set out in SPS 320.10 shall automatically be extended
in the event that an appeal of said orders is filed. The extension of time shall extend to the
termination of the appeal procedure and for such additional time as the Public Works Division may
allow.
(b) The Public Works Division may grant additional reasonable time in which to comply with a
violation order.
(4) APPEALS OF SOIL EROSION CONTROL ORDERS BY THE LAND AND NATURAL RESOURCES
DIVISION FOR CESSATION OF WORK.
(a) Appeals of orders for cessation of work issued under SPS 320.10 (4) may be made to the Land
and Natural Resources Division. The Land and Natural Resources Division shall make a
determination on such appeal within 3 Business Day s.
(c) If the Land and Natural Resources Division determines the site to be compliant with SPS
321.125, the order(s) shall be rescinded and work may commence.
SPS 320.22 Penalties and violations.
(1) VIOLATIONS. No person shall construct or alter any Dwelling in violation of any of the provisions
of this Code. 1
(a) Injunction. When violations occur, the Public Works Division may bring legal action to enjoin
any violations.
(b) Ordinances. This Code shall not affect the enforcement of any ordinance or regulation, the
violation of which occurred prior to the effective date of this Code.
(2) PENALTIES.
(a) In case of violation by any person, the Public Works Division may issue citations on citation
forms Approved by the Executive Council. The penalty for any citations issued pursuant to this
ordinance will be in accordance with the fine schedule Approved by the Executive Council on an
annual basis.
Subchapter IX — Adoption of Standards
SPS 320.24 Adoption of standards.
Public Works Division employees performing any work subject to this Code shall comply with all applicable
standards contained in the Code or be subject to disciplinary action imposed by the Division, up to and including
termination. Such Public Works Division employees shall not be subject to the provisions of SPS 320.22.
1
(2) ADOPTION OF STANDARDS. The standards referenced in Tables 320.24-1 to 320.24-13 are
incorporated by reference into this chapter.
Table 320.24-1 - See PDF for table
Table 320.24-3 - See PDF for table
Table 320.24-4 - See PDF for table
Table 320.24-5 - See PDF for table
Table 320.24-6 - See PDF for table
Table 320.24-6m - See PDF for table
Table 320.24-7 - See PDF for table
Table 320.24-9 - See PDF for table
Table 320.24-10 - See PDF for table
Table 320.24-11 - See PDF for table
Table 320.24-12 - See PDF for table
Table 320.24-13 - See PDF for table
[l
[l
ID
ID
[l
[l
ID
ID
~
ID
tri
ID
..
Table 320.24-4
.
.
ASTM
ASTM International
100 Barr Harbor Drive
PO Box C700
We t Conshohocken. PA
19428-2959
www.astm.ofl!.
tandard Reference
umber
Title
I. C62-13a
Standard Specification for Building Brick (Solid Masonry Uni1
Mooe From Clay or Shale)
Standard Specifica1ion for Loadbearing Concrete Masonry Units
Table 320.24-1
American Concre1e lns1i1u1e
P.O. Box 9094
Farming1on Hills. Ml 48333
ww-.v.concre1e.org
ACI
.
Standard Reference
I umber
Title
I .318-14
Building Code Requirement for
Struc1ural Concre1e
2.332-14
Residential Code Requiremems
for S1ruc1urnl Concre1e
3.530-13
Building Code Requirement for
Masonry
Struc1ures
•
4. 530.1-13
Specification for Masonry
Structures
.
Table 320.24-3
AISC
American lnsti1u1e of Steel
Construction
One Eas1 Wacker Drive. Suite 700
Chicago, IL 60601
www.aisc.org
tandard Reference
umber
Title
A SUAISC 360-10
Specification For Struc1ural Steel
Buildings
2.C90-14
.
3.C216-14
.
4.C270-14a
5. C476-I0
6.C652-14
Standard Specitica1ion for Facing
Brick (Solid Masonry Units Made
•
From Clay or Shale)
Standard Specification for Mortar
for Unil Masonry
•
Standard Specifica1ion for Groui
for IMasonrv
Standard Specification for Hollow
Brick (Hollow Masonry Units
Made From Clav or Shale)
Standard Specification for
Asphalt-Saturn1ed Organic Fell
U ed In Roofing And Water
Proofing
S1andard Specification for
Asphalt Shingle Made From
Glass Felt and Surfaced With
Mineral Granules
Standard SpecificaLion for
Asphalt-Saturated Organic Feh
Shingle Underlnymem Used in
Roofing
.
7. D226/D226M-09
.
. D3462/D3462M
-IOa
9. D4869/D4869M
-15
.
Tobie 320.24-5
Title
Table 320.24-6
A HRAE
f Hea1ing.
G
0329
rg
Table3W�m
ncil
E ui1e 201
uncil. rg
Table 320.24-7
Table 320.24-9
n M nu•
laza. uj1e I
_ 14
ia•
I Batterym h Park
·
A 02269
Qu
wv.
org
n of
and
an-
Table 320.24- 11
T
e-
Evalua
ti n Of
. Third Edition. _()(}
ible
Table 320.24-13
TPI
Truss Plate .Institute, Inc.
l. Uil
14
1/TPI 1-200
1-
Chapter SPS 321
CONSTRUCTION STANDARDS
SPS 321.01 Scope.
Subchapter I — Scope
Subchapter II — Design Criteria
SPS 321.02 Loads and materials.
SPS 321.03 Exits.
SPS 321.035 Interior circulation.
SPS 321.04 Stairways and elevated areas.
SPS 321.042 Ladders.
SPS 321.045 Ramps.
SPS 321.05 Natural light and natural ventilation.
SPS 321.06 Ceiling Height.
SPS 321.07 Attic and crawl space access.
SPS 321.08 Fire separation and Dwelling Unit separation.
SPS 321.085 Fire Blocking.
SPS 321.09 Smoke detectors.
SPS 321.095 Automatic fire sprinklers.
SPS 321.097 Carbon monoxide detectors.
SPS 321.10 Protection against decay and termites.
SPS 321.11 Foam plastic.
SPS 321.115 Installation of elevators or dumbwaiters.
Subchapter III — Excavations
SPS 321.12 Drainage.
SPS 321.125 Erosion control and sediment control.
SPS 321.13 Excavations adjacent to adjoining property.
SPS 321.14 Excavations for footings and Foundations.
Subchapter IV — Footings
SPS 321.15 Footings.
SPS 321.16 Frost protection.
SPS 321.17 Drain tiles.
Subchapter V — Foundations
SPS 321.18 Foundations.
Subchapter VI — Floors
SPS 321.19 Floor design.
SPS 321.20 Concrete floors.
SPS 321.203 Garage floors.
SPS 321.205 Wood floors in contact with the ground.
SPS 321.21 Precast concrete floors.
SPS 321.22 Wood frame floors.
SPS 321.225 Decks.
Subchapter VII — Walls
SPS 321.23 Wall design.
SPS 321.24 Exterior covering.
SPS 321.25 Wood frame walls.
SPS 321.26 Masonry walls.
Subchapter VIII — Roof and Ceilings
SPS 321.27 Roof design and framing.
SPS 321.28 Weather protection for roofs.
Subchapter IX — Fireplace Requirements
SPS 321.29 Masonry fireplaces.
SPS 321.30 Masonry Chimneys.
SPS 321.32 Factory-built fireplaces.
Subchapter X — Construction in Floodplains
SPS 321.33 Construction in Floodplains.
SPS 321.34 Construction in Coastal Floodplains.
Subchapter XI — Installation of Manufactured Homes
SPS 321.40 Installation standards.
Subchapter I — Scope
SPS 321.01 Scope. The provisions of this chapter shall apply to the design and construction of
all one- and 2-family Dwellings.
Subchapter II — Design Criteria
SPS 321.02 Loads and materials. Every Dwelling shall be designed and constructed in
accordance with the requirements of this section.
(1) DESIGN LOAD. Every Dwelling shall be designed and constructed to support the actual
Dead Load, Live Loads and wind loads acting upon it without exceeding the allowable
Stresses of the material. The construction of buildings and structures shall result in a system
that provides a complete load path capable of transferring all loads from point of origin
through the load-resisting elements to the Foundation.
(a) Dead Loads. Every Dwelling shall be designed and constructed to support the actual
weight of all components and materials. Earth-sheltered Dwellings shall be designed and
constructed to support the actual weight of all soil loads.
(b) Live loads.
1. `Floors and ceilings.' Floors and ceilings shall be designed and constructed to
support the minimum Live Loads listed in Table 321.02. The design load shall be
applied uniformly over the component area. - See PDF for table
2. `Snow loads.' Roofs shall be designed and constructed to support the minimum
snow loads listed on the zone map. The loads shall be assumed to act vertically over
the roof area projected upon a horizontal plane.
(c) Wind loads. Dwellings shall be designed and constructed to withstand either a
horizontal and uplift pressure of 20 pounds per square foot acting over the surface area or
the wind loads determined in accordance with ASCE 7–05, Minimum Design Loads for
Buildings and Other Structures.
Note: ASCE 7–05 allows for substantial reduction from 20 psf as applied to the
surface area.
(2) METHODS OF DESIGN. All Dwellings shall be designed by the method of structural
analysis, or the method of accepted practice specified in each part of this Code.
(3) STRUCTURAL STANDARDS.
(a) General. Design, construction, installation, practice, and structural analysis shall
conform to the following nationally recognized standards.
(b) Wood.
1. Except as provided in subd. 1. a. and b., structural lumber, glue-laminated timber,
timber pilings and fastenings shall be designed in accordance with the “National
Design Specification for Wood Construction" and the “Design Values for Wood
Construction," a supplement to the National Design Specification for Wood
Construction.
Figure 321.02
ZONE MAP FOR ROOF LOADS - See PDF for diagram
a. Section 2.2.5.3. The cumulative effects of short time loads, such as snow, shall
be considered in determining duration of load. For snow load, no greater duration
of load factor than 1.15 shall be used.
b. Section 4.1.7. The provisions of this section shall also apply to reused lumber.
Reused lumber shall be considered to have a duration of load factor of 0.90.
2. Span tables for joists and rafters printed in Ch. SPS 325 Appendix A or Approved
by the Department may be used in lieu of designing by structural analysis.
3. Sawn lumber that is not graded in accordance with the standards under subd. 1.,
shall use the NDS published allowable design Stresses for the lumber species using
grade number 3 when used for studs, stringers, rafters, or joists and may use grade
number 1 when used for beams, posts, or timbers.
(c) Structural steel. The design, fabrication, and erection of structural steel for buildings
shall conform to Specification for Structural Steel Buildings and the provisions of the
accompanying commentary as adopted under Table 320.24-3.
(d) Concrete. Plain, reinforced, or prestressed concrete construction shall conform to the
following standards:
1. ACI Standard 318, Building Code Requirements for Structural Concrete.
2. ACI Standard 332, Residential Code Requirements for Structural Concrete.
Note: Concrete construction in one- and two-family Dwellings should meet the
standards established in ACI 332. Construction means, materials, or methods not
addressed in ACI 332 should meet the standards established in ACI 318.
(e) Masonry. The design and construction of masonry shall conform to the following
standards:
1. ACI 530, Building Code Requirements for Masonry Structures.
2. ACI 530.1, Specification for Masonry Structures.
(f) Engineered structural components. Engineered structural components shall be used
in accordance with structural analysis or with load tables supplied by the manufacturer,
provided those load tables were developed using structural analysis or load testing.
(g) Whole logs. Dwellings constructed of whole logs shall conform to ICC 400, Standard
on the Design and Construction of Log Structures.
Note: This standard requires the minimum log diameter to be 8 inches.
(h) Fasteners.
1. All Building Components shall be fastened to withstand the Dead Load, Live Load,
snow load, and wind load.
2. Fasteners shall comply with the schedule listed in Table 321.02-2.
Note: Other fastening methods may be allowed if engineered under SPS 321.02
(3).
Table 321.02-2
MINIMUM FASTENER SCHEDULE TABLE
Other interior and exterior panel products and finishes installed per manufacturer requirements.
For engineered connectors, use manufacturer's specified fasteners. - See PDF for table
- See
PDF for table
1. All nails are smooth-common, box or deformed shank except where otherwise stated.
2. Nail is a general description and may be T-head, modified round head or round head.
3. Staples are 16-gauge wire, unless otherwise noted, and have a minimum 7/16 ‶ o.d.
crown width.
4. Staples shall be spaced at not more than 10 ‶ o.c. at intermediate supports for floors.
5. Apply vertically 4‵ x 8‵ or 4‵ x 9 ‵ panels.
(4) ALTERNATE MATERIALS AND STANDARDS. No part of this Code is intended to prohibit or
discourage use of alternate, equivalent materials or standards; or the construction of
innovative Dwellings such as a Dwelling built below ground, a geodesic dome, a concrete
house, a fiberglass house, or any other nonconventional structure.
Note: Examples of materials addressed by this subsection include structural insulated
panels that are used in accordance with the manufacturer's instructions or structural
analysis, and cold-formed steel framing complying with AISI S230 Standard for ColdFormed Steel Framing — Prescriptive Method for One- and Two- Family Dwellings.
SPS 321.03 Exits. Exits, doors and hallways shall be constructed as specified in this section.
(1) EXITS FROM THE FIRST FLOOR.
(a) Except as allowed under par. (h), every Dwelling Unit shall be provided with at least
2 Exit doors accessible from the First Floor.
(b) At least one of the Exits shall discharge to grade and may not go through a Garage.
This Exit may include interior or exterior Stairs.
Note: Under this paragraph, only one of the two Exit doors that are addressed in par.
(a) is required to exit directly to grade.
(c) Any Exit that does not comply with par. (b) may discharge to an outside Balcony that
complies with sub. (8).
(d) Any Exit that does not comply with par. (b) may discharge into an Attached Garage
provided the Garage has an Exit door that discharges to grade. An overhead Garage door
may not be used as an Exit door.
(e) Except as allowed under pars. (f) and (h), the 2 required Exit doors shall be separated
by at least the greater of the following distances:
1. One-third the length of the longest diagonal of the floor in plan view, exclusive of
an Attached Garage.
2. 20 feet.
Note: See Ch. SPS 325 Appendix A for examples of Exit separation design.
(f)
(g)
1. First Floor levels that do not meet the separation requirements under par. (e), shall
have at least one egress Window complying with sub. (6) on that floor level.
2. An egress Window to comply with subd. 1. shall be separated from at least one door
on the First Floor by one of the distances under par. (e).
3. If First Floor levels that do not meet the separation requirements under
par. (e) contain one or more sleeping rooms, each sleeping room shall have at least one
egress Window complying with sub. (6).
1. The Exit separation distance required under par. (e) shall be calculated or measured
as a straight line from the midpoint of one doorway to the midpoint of the other
doorway.
2. For exiting through an Attached Garage, the separation distance shall be measured
using the door connecting the Garage and the Dwelling. Distance within the Garage
shall be ignored.
(h)
1. Dwellings consisting of no more than a First Floor with a maximum floor area of
400 square feet and a Loft area not exceeding half of the First Floor area, shall be
provided with at least one Exit door leading directly to the exterior and at least one
egress Window that complies with sub. (6).
2.
a. Dwellings that meet the size restrictions under subd. 1., are not required to meet
the exit separation requirements under par. (e) or (f).
b. If a Dwelling that meets the size restrictions under subd. 1., has more than one
room on the First Floor, the door, and the egress Window shall be located in
different rooms.
3. One of the Exit doors required in par. (a) may be omitted for a Dwelling Unit that
has one or more egress Windows on the First Floor. If there are bedrooms, each must
have a Window that complies with sub. (6).
(2) EXITS FROM THE SECOND FLOOR.
(a) At least 2 Exits shall be provided from the second floor. At least one of the Exits shall
be a Stairway or ramp and lead to the First Floor or discharge to grade. The second Exit
may be via a Stairway or ramp that discharges to grade, or to a Balcony which complies
with sub. (8), or to a Deck that complies with SPS 321.225 and that is no more than 15
feet above the grade below.
(b) Windows that comply with sub. (6) may be provided in each second floor bedroom —
or in another location on the second floor if there are no bedrooms on that floor — in lieu
of the second Exit from that floor.
(c) Where the second floor of a building is the lowest floor level in a Dwelling Unit, as in
an up-and-down duplex, no Exit from the unit may go through another Dwelling Unit or
other party's occupancy on the First Floor.
(3) EXITS ABOVE THE SECOND FLOOR.
(a) Except as provided under pars. (b) and (c), each habitable floor above the second
floor shall be provided with at least 2 Exits that meet all of the following requirements:
1. The Exits shall be Stairways or ramps that lead to the second floor or discharge to
grade.
2. The Exits shall be located such that an Exit is accessible to the second floor if
another Exit is blocked.
(b) A second Stairway or ramp Exit is not required for habitable areas on a third floor
that meet all of the following requirements:
1. The habitable area consists of a single room.
Note: Non-habitable areas, such as closets and bathrooms may be partitioned off.
2. The room is not used for sleeping.
3. The habitable area has a floor area of 400 square feet or less.
4. There is at least one egress Window meeting the requirements of sub. (6) in the
habitable area.
(c) A second Stairway or ramp Exit is not required for habitable areas on a third floor that
meet all of the following requirements:
1. The Dwelling is fully sprinklered in accordance with NFPA 13R or NFPA 13D.
2. If a required Exit includes an Attached Garage, the Garage shall be sprinklered.
(4) EXITS FROM LOFTS.
(a) At least one Stairway Exit shall be provided, to the floor below, for a Loft exceeding
400 square feet in area.
(b) At least one Stairway or ladder Exit shall be provided to the floor below for a Loft,
400 square feet or less, in area.
(5) EXITS FROM BASEMENTS AND GROUND FLOORS.
(a) General. Except as provided in par. (b), all Basements and Ground Floors shall be
provided with at least one Exit of the following types:
1. A door to the exterior of the Dwelling.
2. A Stairway or ramp that leads to the floor above.
(b) Basements and Ground Floors used for sleeping.
1. Basements and Ground Floors used for sleeping shall be provided with at least 2
Exits.
2. The Exits shall be located as far apart as practical.
3. The Exits may not be accessed from the same ramp or Stairway.
4. In addition to the Exit type required under par. (a), the second Exit from a Basement
or Ground Floor used for sleeping shall be one of the following types:
a. A door to the exterior of the Dwelling.
b. A Stairway or ramp that leads to the floor above.
c. A Stairway that leads to a Garage provided the Garage has an Exit door other
than the overhead door.
d. An egress Window that complies with sub. (6), located in each bedroom.
(6) WINDOWS USED FOR EXITING. Windows which are installed for Exit purposes shall
comply with the requirements of this subsection.
(a) The Window shall be openable from the inside without the use of tools or the removal
of a sash. If equipped with a storm or screen, it shall be openable from the inside.
(b)
1. The nominal size of the net clear Window opening shall be at least 20 inches by 24
inches irrespective of height or width. Nominal dimensions shall be determined by
rounding up fractions of inches if they are ½-inch or greater or rounding down
fractions of inches if they are less than ½-inch.
2. No portion of the Window, including stops, stools, meeting rails and operator arms,
shall infringe on the required opening.
(c) The area and dimension requirements of par. (b) may be infringed on by a storm
Window.
(d)
1. For any Window used for Exiting, the lowest point of clear opening shall be no
more than 60 inches above the floor.
2. If the lowest point of clear opening is more than 46 inches above the floor, a
permanent platform or fixture shall be installed such that a flat surface at least 20
inches wide and 9 inches deep is located no more than 46 inches directly below the
clear opening.
3. The topmost surface of the platform or fixture shall be no more than 24 inches
above the floor.
4. The topmost surface of the platform or fixture shall support a Live Load of at least
200 pounds.
5. A Stair used for the sole purpose of reaching the top of the platform or fixture is
exempt from the requirements of SPS 321.04.
(e)
1. An egress Window with any point of clear opening below adjacent grade shall be
provided with an areaway in accordance with this section.
2. The width of the areaway shall be at least equal to the width of the Window.
3. The areaway shall be a minimum of 36 inches measured perpendicular from the
outer surface of the below grade wall.
4. If the bottom of the areaway is more than 46 inches below adjacent grade or the top
of the areaway enclosure, the areaway shall be provided with a ladder or Stair to aid
egress. Stairs used to comply with this section are exempt from the requirements of
SPS 321.04.
5.
a. Ladders or other Stairs used to comply with subd. 4. may infringe on the
required area of the areaway by a maximum of 6 inches.
b. Ladder rungs shall have a minimum inside width of at least 12 inches and shall
project at least 3 inches from the wall behind the ladder.
c. Ladder rungs shall be able to support a concentrated load of 200 pounds.
d. Ladder rungs shall have a maximum rise of 12 inches between rungs and shall
extend to within 12 inches of exterior grade.
6. The areaway shall be constructed such that water entering the areaway does not
enter the Dwelling.
(f) An egress Window under a Deck or Porch shall discharge through a clear path of at
least 36 inches in height and 36 inches in width, and no more than 15 feet in length, to a
yard or open space.
Note: Under this paragraph, there is no maximum height above grade for an egress
Window. Similarly, egress Windows are not prohibited from discharging to a roof,
regardless of the slope of the roof.
(7) DOORS USED FOR EXITING.
(a) Doors used for exiting from a Dwelling shall meet the following dimensions:
1. At least one Exit door shall be a swing-type door at least 80 inches high by 36
inches wide.
2. Except as allowed under subds. 3. and 4., other required Exit doors shall be at least
76 inches high by 32 inches wide.
3. Where double doors are used as a required Exit, each door leaf shall provide a clear
opening at least 30 inches wide and be at least 76 inches high.
4. Where sliding doors are used as a required Exit, the clear opening shall be at least
29 inches wide and be at least 76 inches high.
(b) All Exit doors shall be openable from the interior without the use of a key.
(8) BALCONIES.
(a) Balconies shall be made of concrete, metal or wood which is treated, protected or
naturally decay-resistive in accordance with SPS 321.10.
(b) Balconies shall be provided with Guards in accordance with SPS 321.04 (3).
(c) Balconies which are required for Exit purposes shall also comply with all of the
following requirements:
1. The Balcony Guard shall terminate no more than 46 inches above the floor level of
the Balcony.
2. The floor level of the Balcony shall be no more than 15 feet above the grade below.
3. The floor of the Balcony shall have minimum dimensions of 3 feet by 3 feet. The
Guard and its supports may infringe on the dimensions of the required area no more
than 4.5 inches.
(9) SPLIT LEVEL DWELLINGS. In determining the Exit requirement in a split-level Dwelling,
all levels that are to be considered a single Story shall be within 5 feet of each other.
(10) TWO-FAMILY DWELLINGS. In a 2-family Dwelling, each Dwelling Unit shall be
provided with Exits in compliance with this section.
(11) EXITS TO COURTYARDS. No Exit may discharge to a courtyard having a perimeter that
is entirely enclosed by exterior building walls or other obstructions that prevent pedestrian
passage.
SPS 321.035 Interior circulation.
(1) DOORS AND OPENINGS. All doors and openings to the following areas shall be at least 80
inches high and provide either a net clear opening width of 30 inches or be a 32-inch door:
(a) Except as provided under pars. (b) and (c), all entrances into Common Use Areas.
(b) At least 50% of the bedrooms.
(c)
1. At least one full bathroom, including doors or openings to a sink, toilet and tub or
shower. If this bathroom is accessible only through a bedroom, the bedroom door shall
meet the minimum width requirements of this section.
2. If one or more full bathrooms are provided on the First Floor, the bathroom meeting
the requirements under this section shall be on the First Floor.
Note: This section does not require a full bathroom on the First Floor.
(2) HALLWAYS.
(a) Except as allowed under par. (b), the clear width of hallways shall be at least 36
inches.
(b) The following are allowed to infringe on the required clear width of a hallway:
1. Door hardware and finish trim.
2. Handrails may infringe into the minimum width of a hallway up to 4½ inches on
each side.
3. Heating registers may infringe into the minimum width of a hallway up to
4½ inches and no part of the register may be more than 38 inches above the floor.
4. Ducts, pipes, light fixtures, structural features, and corner treatments that are within
84 inches of the floor may infringe into the minimum width of a hallway by a
maximum of 4½ inches on each side.
5. Unlimited infringements are allowed in a hallway more than 84 inches above the
floor.
(3) KITCHENS.
(a) There shall be at least 30 inches of clearance between a wall, a permanently installed
Kitchen island, permanently installed Kitchen cabinets and the following Kitchen
appliances, if provided:
1. A range, cook top or oven.
2. A sink, refrigerator, or freezer.
(b) Measurements shall be taken from the face of the wall, island, cabinet, or appliance,
ignoring knobs and handles.
Note: See ICC/ANSI A117.1 chapter 10 for more guidelines relating to doors and
accessible routes. Under that standard, doors must be at least 80-inches in height and
provide a minimum net clear opening of 31¾-inches in width in order to provide
accessibility for people with disabilities.
SPS 321.04 Stairways and elevated areas.
(1) SCOPE.
(a) General. Except as provided under par. (b), the following Stairways shall conform to
the requirements of this section.
1. Every interior and exterior Stairway attached to, or supported by any part of the
structure covered under this Code.
2. Tub access Stairs, unless they are an integral part of an Approved plumbing
product.
(b) Exceptions. The following Stairways are not required to comply with the
requirements of this section:
1. Stairways leading to non-habitable Attics or crawl spaces.
2. Non-required Stairways connecting the Basement directly to the exterior of the
structure without communicating with any other part of the structure.
(2) DETAILS.
(a) Width.
1. Except for spiral Staircases under subd. 2., Stairways shall measure at least 36
inches in width. Handrails and associated trim may project a maximum of 4.5 inches
into the required width at each side of the Stairway. The minimum clear width at and
below the Handrail, including at treads and Landings, may not be less than 31.5 inches
where a Handrail is installed on one side, and 27 inches where Handrails are provided
on both sides.
2. Spiral staircases shall be at least 26 inches wide measured from the outer edge of
the supporting column to the inner edge of the Handrail.
(b) Riser height.
1.
a. Except for spiral staircases under subd. 2., risers may not exceed 8 inches in
height measured vertically from tread to tread.
b. At the top and bottom of a Flight, measurement shall be taken from the top of
the nosing to the finished floor surface unless the finished surface is carpeting, in
which case measurement shall be made to the hard surface below the carpeting.
2. Risers in spiral staircases may not exceed 9.5 inches in height measured vertically
from tread to tread.
(c) Tread depth.
1. `Rectangular treads.' Rectangular treads shall have minimum tread depth of 9
inches measured horizontally from nosing to nosing.
2. `Spiral staircase treads.' Spiral staircase treads shall have a minimum tread depth
of 7 inches from nosing to nosing measured at a point 12 inches from the outer edge of
the center column.
3. `Winder treads in series.' Two or more winder treads may be placed immediately
adjacent to each other anywhere in a Stairway provided both of the following
conditions are met:
a. The winder treads shall have a minimum tread depth of 7 inches measured at a
point 12 inches from the narrow end of the tread.
b. The depth of the immediately adjoining winder treads shall be equal at a point
12 inches from the narrow end of the tread or inside face of spindles or balusters.
c. Winder treads may not be used on a straight Stairway.
4. `Individual winder treads.'
a. An individual winder tread may be placed between rectangular treads or at the
end of a Flight of rectangular treads provided the tread depth is at least 9 inches,
when measured at a distance of 12 inches from the narrow end of the tread or
from the inside face of the wall.
b. There may be more than one individual winder tread in a Stairway.
c. Winder treads may not be used on a straight Stairway.
(d) Headroom.
1. Stairways shall be provided with a minimum headroom clearance of 80 inches
measured vertically from a line parallel to the nosing of the treads to the ceiling, soffit,
or any overhead obstruction directly above that line.
2. The headroom clearance shall be maintained over an intermediate Landing.
3. The headroom clearance shall be maintained over a Landing that is at the top or
bottom of a Stairway for a minimum distance of 36 inches in the direction of travel of
the Stairway.
(e) Uniformity.
1. Within a Stairway Flight, the greatest tread depth may not exceed the smallest tread
depth by more than 3/8 inch and the greatest riser height may not exceed the smallest
riser height by more than 3/8 inch.
2. The allowed variation in uniformity under subd. 1. may not be used to exceed the
maximum riser height under par. (b) or to decrease the minimum tread depth under
par. (c).
(f) Open risers. Stairways with open risers shall be constructed to prevent the throughpassage of a sphere with a diameter of 4 inches or larger between any 2 adjacent treads.
(g) Walking surface. The walking surface of Stair treads and Landings shall be a planar
surface that is free of lips or protrusions that could present a tripping hazard.
(3) HANDRAILS AND GUARDS.
(a) General.
1. A Flight of Stairs with more than 3 risers shall be provided with at least one
Handrail for the full length of the Flight.
2. Guards shall be provided on all open sides of Stairs consisting of more than 3 risers
and on all open sides of areas that are elevated more than 24 inches above the floor or
exterior grade.
Note: A Handrail provided at 30 to 38 inches above the tread nosing meets the
height requirement for a Guard on a Stairway.
3.
4.
a. Except as provided in subd. 3. b., Guards shall be constructed to prevent the
through-passage of a sphere with a diameter of 4 3/8 inches, when applying a
force of 4 pounds.
b. The triangular area formed by the tread, riser and bottom rail shall have an
opening size that prevents the through-passage of a sphere with a diameter of 6
inches, when applying a force of 4 pounds.
c. Rope, cable, or similar materials used in Guard infill shall be strung with
maximum openings of 3 1/2 inches with vertical supports a maximum of 4 feet
apart.
Note: In some cases, the vertical supports could be simple cable stays that
offer vertical support to the rope or cable span. Structural posts must be
supplied to provide the rail with the minimum 200-pound load resistance, as
well as to resist the tensile loads exerted by the tightened rope or cable.
a. Handrails and Guards shall be designed and constructed to withstand a 200pound load applied in any direction.
b. Handrail or Guard infill components, balusters and panel fillers shall withstand
a horizontally applied perpendicular load of 50 pounds on any one-foot-square
area.
c. Glazing used in Handrail or Guard assemblies shall be safety glazing.
5. Exterior Handrails and Guards shall be constructed of metal, decay resistant or
pressure-treated wood, or shall be protected from the weather.
(b) Handrails.
1. `Height.'
a. Handrails shall be located at least 30 inches, but no more than 38 inches above
the nosing of the treads, except as provided in subds. 1. b. to d. Measurement shall
be taken from the hard structural surface beneath any finish material to the top of
the rail. Variations in uniformity are allowed only when a rail contacts a wall or
newel post or where a turnout or volute is provided at the bottom tread.
b. A volute, turnout, or starting easing that does not comply with subd. 1. a. may
extend over the lowest tread.
c. Transition fittings on Handrails may extend above the 38-inch height limit.
d. Where Handrail fittings or bendings are used to provide a continuous transition
between Flights, or at winder treads, or from a Handrail to a Guard, or at the start
of a Flight, the height at the fittings or bendings may exceed 38 inches.
2. `Clearance.' The clearance between a Handrail and the wall surface shall be at least
1 1/2 inches.
3. `Winders.'
a. Except as provided under subd. 3. b., the required Handrail on winder Stairs
shall be placed on the side where the treads are wider.
b. Where all winder treads in a Flight have a depth of at least 9 inches from
nosing to nosing measured at a point 12 inches from the narrow end of the tread,
the required Handrail may be located on either side of the Stairway.
4. `Projection.' Handrails and associated trim may project into the required width of
Stairs and Landings a maximum of 4 1/2 inches on each side.
5. `Size and configuration.' Handrails shall be symmetrical about the vertical
centerline to allow for equal wraparound of the thumb and fingers.
a. Handrails with a round or truncated round cross-sectional gripping surface shall
have a maximum whole diameter of 2 inches.
b. Handrails with a rectangular cross sectional gripping surface shall have a
maximum perimeter of 6 1/4 inches with a maximum cross sectional dimension of
2 7/8 inches.
c. Handrails with other cross sections shall have a maximum cross-sectional
dimension of the gripping surface of 2 7/8 inches with a maximum linear gripping
surface measurement of 6 1/4 inches and a minimum linear gripping surface of 4
inches.
Note: See Ch. SPS 325 Appendix A for further information on Handrail
measurement.
6. `Continuity.' Handrails shall be continuous for the entire length of the Stairs except
in any one of the following cases:
a. A Handrail may be discontinuous at an intermediate Landing.
b. A Handrail may have newel posts.
c. A Handrail may terminate at an intermediate wall provided the lower end of the
upper rail is returned to the wall or provided with a flared end, the horizontal
offset between the 2 rails is no more than 12 inches measured from the center of
the rails, and both the upper and lower rails can be reached from the same tread
without taking a step.
(c) Guards.
1. `Application.'
a. All openings between floors, and open sides of Landings, platforms, balconies,
or Porches that are more than 24 inches above grade or a floor shall be protected
with Guards.
b. The requirements under subd. 1. a. apply where insect screens are the only
means of enclosure or protection for a surface that is more than 24 inches above
grade or a floor.
c. For exterior applications, the 24-inch vertical measurement shall be taken from
the lowest point within 3 feet horizontally from the edge of the Deck, Landing,
Porch, or similar structure.
d. This paragraph does not apply to Window wells, egress wells, and retaining
walls.
2. `Height.' Guards shall extend to at least 36 inches above the floor or to the
underside of a Stair Handrail complying with SPS 321.04 (3) (b). Measurement shall
be taken from the hard structural surface beneath any finish material to the top of the
Guard.
3. `Opening size.' Guards shall be constructed to prevent the through-passage of a
sphere with a diameter of 4 3/8 inches, when applying a force of 4 pounds.
(4) LANDINGS.
(a) Intermediate Landings.
1. A level intermediate Landing shall be provided in any Stairway with a height of 12
feet or more.
2. Intermediate Landings that connect 2 or more straight Flights of Stairs, or 2 Flights
of Stairs at a right angle, shall be at least as wide as the treads and shall measure at
least 36 inches in the direction of travel.
3. Curved or irregular Landing shall have a radius of at least 36 inches.
4. Curved or irregular Landings shall have a minimum straight-line measurement of 26
inches between the nosing of the 2 connecting treads measured at a point 18 inches
from the narrow end of the Landing measured along the nosing of the 2 treads.
(b) Landings at the top and base of Stairs. A level Landing shall be provided at the top
and base of every Stairs except as provided in par. (d). The Landing shall be at least as
wide as the treads and shall measure at least 3 feet in the direction of travel.
(c) Doors at Landings. Except as provided in subds. 1. to 3. and par. (d), level Landings
shall be provided on each side of any door located at the top or base of a Stair, regardless
of the direction of swing. In the following exceptions, a Stairway between a Dwelling and
an Attached Garage, Carport or Porch is considered to be an interior Stair:
1. A Landing is not required between the door and the top of interior Stairs if the door
does not swing over the Stairs.
2. A Landing is not required between the door and the top of an interior Stairs of 1 or
2 risers regardless of the direction of swing.
3. A Landing is not required between a sliding glass door or an in-swinging glass door
and the top of an exterior Stairway of 3 or fewer risers.
(d) Exterior Landings.
1. The exterior Landing, platform, or sidewalk at an exterior doorway shall be located
a maximum of 7 ¾ inches below the interior floor elevation, be sloped away from the
doorway at a minimal rate that ensures drainage and have a length of at least 36 inches
in the direction of travel out of the Dwelling.
2. The Landing at the base of an exterior Stair shall be sloped away from the Stair at a
minimal rate that ensures drainage.
SPS 321.042 Ladders. Ladders which are used as part of a required Exit shall conform to this
section.
(1) DESIGN LOAD. Ladders shall be designed to withstand loads of at least 200 pounds.
(2) TREAD OR RUNGS.
(a) Minimum tread requirements shall be specified in Table 321.042. Treads less than 10
inches in width shall have open risers. All treads shall be uniform in dimension.
(b) Rungs may only be used for ladders with a pitch range of 75° to 90°. Rungs shall be
at least 1 inch in diameter for metal ladders and 1 1/2 inch for wood ladders. All rungs
shall be uniform in dimension.
(3) RISERS. Risers shall be uniform in height and shall conform with Table 321.042.
(4) WIDTH. The width of the ladder shall be a minimum of 20 inches wide and a maximum
of 30 inches wide.
(5) HANDRAILS.
(a) Handrails shall be required for ladders with pitches less than 65°.
(b) Handrails shall be located so the top of the Handrail is at least 30 inches, but not more
than 38 inches, above the nosing of the treads.
(c) Open Handrails shall be provided with intermediate rails or an ornamental pattern
such that a sphere with a diameter of 6 inches or larger cannot pass through.
(d) The clearance between the Handrail and the wall surface shall be at least 1½ inches.
(e) Handrails shall be designed and constructed to withstand a 200-pound load applied in
any direction.
(6) CLEARANCES.
(a) The ladder shall have a minimum clearance of at least 15 inches on either side of the
center of the tread.
(b) The edge of the tread nearest to the wall behind the ladder shall be separated from the
wall by at least 7 inches.
(c) A passageway clearance of at least 30 inches parallel to the slope of a 90° ladder shall
be provided. A passageway clearance of at least 36 inches parallel to the slope of a
75° ladder shall be provided. Clearances for intermediate pitches shall vary between these
2 limits in proportion to the slope.
(d) For ladders with less than a 75° pitch the vertical clearance above any tread or rung to
an overhead obstruction shall be at least 6 feet 4 inches measured from the leading edge
of the tread or rung.
SPS 321.045
Ramps.
(1) GENERAL. Every exterior or interior ramp which leads to or from an Exit shall comply
with the requirements of this section.
Note: See ICC/ANSI A117.1 chapter 5 for more guidelines relating to the design and
construction of an accessible ramp. Under that standard, ramps along an accessible route
for people with disabilities should have a slope of not more than 1-foot of rise in 12-feet
of run and should have Handrails on both sides of the ramp.
(2) SLOPE. Ramps shall not have a gradient greater than 1 in 8 or one foot of rise in 8 feet of
run. Walkways with gradients less than 1 in 20 or one foot of rise in 20 feet of run are not
considered to be ramps.
(3) SURFACE AND WIDTH. Ramps shall have a slip resistant surface and shall have a
minimum width of 36 inches measured between Handrails.
(4) HANDRAILS. Handrails shall be provided on all open sides of ramps. Every ramp that
overcomes a change in elevation of more than 8 inches shall be provided with at least one
Handrail.
(a) Ramps which have a gradient greater than 8.33% or 1:12 or one foot rise in 12 feet of
run and which overcome a change in elevation of more than 24 inches, shall be provided
with Handrails on both sides.
(b) Handrails shall be located so the top of the Handrail is at least 30 inches, but not more
than 38 inches above the ramp surface.
(c)
1. Open-sided ramps shall have the area below the Handrail protected by intermediate
rails or an ornamental pattern to prevent the passage of a sphere with a diameter of 4
3/8 inches when applying a force of 4 pounds, except as provided in subd. 2.
2. This paragraph does not apply to ramps having a walking surface that is less than 24
inches above adjacent grade, if a toe-kick or side rail is provided to 4 inches above the
walking surface, and a mid-rail is provided between the toe-kick or side rail and the
Handrail.
(d) The clear space between the Handrail and any adjoining wall shall be at least
1½ inches.
(5) LANDINGS. A level Landing shall be provided at the top, at the foot and at any change in
direction of the ramp. The Landing shall be at least as wide as the ramp and shall measure at
least 3 feet in the direction of travel.
SPS 321.05 Natural light and natural ventilation.
(1) NATURAL LIGHT. Each Habitable Room shall be provided with natural light by means of
glazed openings. The area of the glazed openings shall be at least 8% of the net floor area,
except under the following circumstances:
(a) Exception. Habitable Rooms, other than bedrooms, located in Basements, Ground
Floors or above Garages do not require natural light.
(b) Exception. Natural light may be obtained from adjoining areas through glazed
openings, louvers, or other Approved methods. Door openings into adjoining areas may
not be used to satisfy this requirement.
(1m) NET FLOOR AREA. For the purposes of subs. (1) and (2), “net floor area" does not
include any area with a Ceiling Height of less than 5 feet.
(2) VENTILATION.
(a) Natural ventilation.
1. Natural ventilation shall be provided to each Habitable Room by means of openable
doors, skylights, or Windows. The net area of the openable doors, skylights or
Windows shall be at least 3.5% of the net floor area of the room, except as provided in
subd. 2. Balanced mechanical ventilation may be provided in lieu of openable exterior
doors, skylights or Windows provided the system is capable of providing at least one
air change per hour of fresh outside air while the room is occupied. Infiltration may
not be considered as make-up air for balancing purposes.
2. Any area with a Ceiling Height of less than 5 feet may be excluded from the net
floor area.
(b) Exhaust ventilation. All exhaust ventilation shall terminate outside the building.
(3) SAFETY GLASS.
(am) Except as provided in par. (bm), glazing shall consist of safety glass meeting the
requirements of either 16 CFR Part 1201 or ANSI Z97.1 when installed in any of the
following locations:
1. In any sidelight or glazing adjacent to a door, that meets all of the following:
a. The nearest point of the glazing is within 2 feet of the door when the door is in
the closed position.
b. The nearest point of the glazing is within 5 feet of the floor.
c. The plane of the glazing is within 30 degrees of the plane of the door when the
door is in the closed position.
2. In any wall where the glazing is within 5 feet vertically of the lowest drain inlet and
within 3 feet horizontally of the nearest part of the inner rim of a bathtub, hot tub,
shower, spa, or whirlpool appliance.
3. Within 4 feet vertically of a tread or Landing in a Stairway and within one foot
horizontally of the near edge of the tread or Landing.
4. Within 4 feet vertically of the floor and 3 feet horizontally of the nosing of the top
or bottom tread of a Stair.
5. In Guard assemblies.
(bm) Safety glass is not required where glazing meets any of the following:
1. The size of an individual pane of glass is 8 inches or less in the least dimension.
2. The safety glass is required by sub. (3) (am) 1. and the only door within 2 feet of the
glazing is the fixed panel of a patio door.
3. The safety glass is required by sub. (3) (am) 1. and there is an intervening wall or
other permanent barrier between the door and the glazing.
Note: The U.S. Consumer Product Safety Commission requires safety glass for
glazing in internal and external doors, including storm doors and patio doors, as
well as for the tub or shower enclosures themselves. These federal rules,
contained in 16 CFR, subchapter B, part 1201, apply in addition to any state rules
or statutes.
Note: Glass blocks are considered to be masonry products and are regulated under
the ACI 530 standard adopted under SPS 320.24. They are not required to be
safety glazing.
SPS 321.06 Ceiling Height All Habitable Rooms, Kitchens, hallways, bathrooms, and corridors
shall have a Ceiling Height of at least 7 feet, except as follows:
(1)
(a) Rooms may have Ceiling Heights of less than 7 feet provided at least 50% of the
room's floor area has a Ceiling Height of at least 7 feet. Any area with a Ceiling Height of
less than 5 feet may be ignored in this calculation.
(b) The 50% limit in par. (a) does not apply to subs. (3) to (6).
(2) Beams and girders or other projections may project to no more than 8 inches below the
required Ceiling Height.
(3) The Ceiling Height extending back from the front edge of a water closet may slope to
below 7 feet, but may not go below 5 feet until beyond the back of the water closet.
(4) The Ceiling Height extending back from the front edge of a lavatory may be less than 7
feet, but may not go below 5 feet until beyond the back of the lavatory.
(5) A Ceiling Height of less than 7 feet may be provided between the rear rim of a bathtub
and a wall of the room abutting that rim, or between the side rim and a room wall abutting
that rim.
(6) A Ceiling Height of less than 7 feet may be provided between the rear wall of a shower
stall and a wall of the room abutting that rear wall, or between the side wall of a shower and a
room wall abutting that side wall.
Note: Section SPS 384.20 (5) (o) 4. establishes minimum horizontal clearances for water
closets, and reads as follows: “A water closet may not be located closer than 15 inches
from its center to any side wall, partition, vanity, or other obstruction, nor closer than 30
inches center to center, between water closets. There shall be at least 24 inches clearance
in front of a water closet to any wall, fixture or door."
Note: See Ch. SPS 384 Appendix for further explanatory material.
SPS 321.07 Attic and crawl space access.
(1) ATTIC. Attics with 150 or more square feet of area and 30 or more inches of clear height
between the top of the ceiling framing and the bottom of the rafter or top truss chord framing
shall be provided with an access opening of at least 14 by 24 inches, accessible from inside
the structure.
(2) CRAWL SPACES. Crawl spaces with 18 inches of clearance or more between the crawl
space floor and the underside of the house floor joist framing shall be provided with an access
opening of at least 14 by 24 inches.
Note: Access to plumbing or electrical systems may be required under chs. SPS
382 to 387, Plumbing Code or ch. SPS 316, Electrical Code, Volume 2.
SPS 321.08 Fire separation and Dwelling Unit separation.
(1) FIRE SEPARATION. Dwelling Units shall be separated from Garage spaces, accessory
buildings, property lines and other Dwelling Units in accordance with Table 321.08 and the
following requirements: - See PDF for table
1. Distance shall be measured perpendicular from wall to wall or property line,
ignoring overhangs.
2. Fire rated construction shall protect the Dwelling from an exterior fire source.
3. Fire rated construction may be in either facing wall.
4. Fire rated construction shall be in both facing walls.
5. The methods for Garage separation in par. (a) 1. are examples of ¾ hour wall
construction.
(a) Attached Garages.
1. The walls and ceiling between an Attached Garage and any portion of the Dwelling,
including Attic or soffit areas, shall be ¾-hour fire-resistive construction or shall be
constructed as specified in any of the following:
a. One layer of 5/8-inch Type X gypsum drywall shall be used on the Garage side
of the separation wall or ceiling.
b. One layer of ½-inch gypsum drywall shall be used on each side of the
separation wall or ceiling.
c. Two layers of ½-inch gypsum drywall shall be used on the Garage side of the
separation wall or ceiling.
2. For all methods listed under subd. 1., drywall joints shall comply with one of the
following:
a. Joints shall be taped or sealed.
b. Joints shall be fitted so that the gap is no more than 1/20-inch with joints
backed by either solid wood or another layer of drywall such that the joints are
staggered.
Note: 1/20-inch is approximately the thickness of a U.S. dime.
3. Vertical separations between an Attached Garage and a Dwelling shall extend from
the top of a concrete or masonry Foundation to the underside of the roof sheathing or
fire-resistive ceiling construction.
(b) Structural elements exposed in an Attached Garage. Beams, columns and bearing
walls which are exposed to the Garage and which provide support for habitable portions
of the Dwelling shall be protected by one of the methods specified in par. (a) 1. a. or c. or
other ¾ hour fire-resistive protection.
(c) Doors.
1. The door and frame assembly between the Dwelling Unit and an Attached Garage
shall be labeled by an independent testing agency as having a minimum fire-resistive
rating of 20 minutes. The test to determine the 20-minute rating is not required to
include the hose stream portion of the test.
Note: Acceptable tests for fire rating of door assemblies include ASTM E-152,
UL 10B, and NFPA 252.
2. Only glazing allowed by the door's listing may be installed in any door required
under this section.
(d) Other openings.
1. Access openings in fire separation walls or ceilings shall be protected in one of the
following ways:
a. The opening is protected with a material that has a finish rating of at least 20
minutes.
b. The opening is protected in the same way as the wall or ceiling where the
opening is located.
2. The cover or door of the access opening shall be permanently installed with
hardware that will maintain it in the closed position when not in use.
(2) DWELLING UNIT SEPARATION.
(a) General. In 2-family Dwellings, Dwelling Units shall be separated from each other
and from shared tenant spaces including Attics, Basements, Garages, vestibules, and
corridors.
(b) Attic separation. Dwelling Units with Attic space that extends over both units shall
be separated in accordance with one of the following:
1. `Complete separation.' The units shall be provided with wall construction under
par. (d) that extends all the way to the underside of the roof Deck.
2. `Vertical and horizontal separation.'
a. The units shall be provided with wall construction under par. (d) that extends to
the Dwelling Unit ceiling and ceiling construction under par. (e).
b. Dwelling Units using this method of separation shall provide Attic draft
stopping under par. (f) that extends all the way to the underside of the roof Deck
above and in line with the separation wall.
(c) Doors. Any door installed in the Dwelling Unit separation shall have the door and
frame assembly labeled by an independent testing agency as having a minimum fireresistive rating of 20 minutes. The test to determine the 20-minute rating is not required
to include the hose stream portion of the test.
(d) Walls. Walls in the Dwelling Unit separation shall be protected by not less than one
layer of 5/ 8-inch Type X gypsum wallboard or 2 layers of ½-inch gypsum wallboard or
equivalent on each side of the wall with joints in compliance with sub. (1) (a) 2.
(e) Floors and ceilings. A fire protective membrane of one layer of 5/8-inch Type X
gypsum wallboard with joints in compliance with sub. (1) (a) 2., shall be provided on the
ceiling beneath the floor construction that provides the separation.
(f) Draft stopping for concealed roof spaces and Attics.
1. Attic areas, mansards, overhangs, and other concealed roof spaces shall be draft
stopped above and in line with the separation wall.
2. Acceptable draft stopping materials include:
a. 3/8-inch wood structural panel.
b. ½ -inch gypsum board.
(3) PENETRATIONS.
(a) Ducts.
1. Except as allowed under subd. 2., all heating and ventilating ducts that penetrate a
required separation shall be protected with a listed fire damper with a rating of at least
90 minutes.
2. The fire damper required under subd. 1. may be omitted in any of the following
cases:
a. There is a minimum of 6 feet of continuous steel ductwork on at least one side
of the penetration.
b. The duct has a maximum cross-sectional area of 20 square inches.
(b) Electrical and plumbing components. Penetrations of a required separation by
electrical and plumbing components shall be firmly packed with noncombustible material
or shall be protected with a listed through-penetration firestop system with a rating of at
least one hour.
(c) Plastic Piping. Penetrations of a required separation by plastic pipe shall be protected
by a penetration firestop system Approved by the Department and installed as tested in
accordance with ASTM E 814 or UL 1479, with a minimum positive pressure differential
of 0.01 inch of water (3 pa), and shall have an F rating of not less than the required fireresistance rating of the assembly penetrated.
SPS 321.085 Fire Blocking.
(1) FIRE BLOCKING LOCATIONS. Fire Blocking shall be provided in all of the following
locations:
(a) In concealed spaces of walls and partitions, including furred spaces, at the ceiling and
floor levels.
(b) At all interconnections between concealed vertical and horizontal spaces including
the attachment between a Carport and a Dwelling.
(c) In concealed spaces between Stair stringers at the top and bottom of the run and at any
intervening floor level.
(d) At all openings around wires, cables, Vents, pipes, ducts, Chimneys and fireplaces at
ceiling and floor level.
(2) FIRE BLOCKING MATERIALS. Fire Blocking shall consist of one of the following:
(a) 2-inch nominal lumber.
(b) Two layers of one-inch nominal lumber.
(c) One thickness of ¾-inch nominal plywood or wood structural panel with any joints
backed with the same material.
(d) One thickness of ½-inch gypsum wallboard, face nailed, or face screwed to solid
wood, with any joints backed with the same material.
(e) Fiberglass or mineral wool batt insulation may be used if both of the following
conditions are met:
1. The least dimension of the opening may not exceed 4 inches.
2. The batt shall be installed to fill the entire thickness of the opening or stud cavity.
(f) For wires, cables, pipes and Vents only, non-shrinking caulk, putty mortar, or similar
material may be used provided no dimension of the opening exceeds ½ inch around the
penetrating object.
(g) For Chimneys, fireplaces, and metal Vents, Fire Blocking shall be metal, cement
board or other noncombustible material.
SPS 321.09 Smoke detectors.
(1) A listed and labeled multiple-station smoke alarm with battery backup shall be installed
in all of the following locations:
(a) An alarm shall be installed inside each sleeping room.
(b) On floor levels that contain one or more sleeping areas, an alarm shall be installed
outside of the sleeping rooms, within 21 feet of the centerline of the door opening to any
sleeping room and in an Exit path from any sleeping room.
(c) On floor levels that do not contain a sleeping area, an alarm shall be installed in a
common area on each floor level.
Note: This Code requires the Owner of a Dwelling to install a functional smoke
detector in the Basement of the Dwelling and on each floor level except the Attic or
storage area of each Dwelling Unit. The occupant of such a Dwelling Unit shall
maintain any smoke detector in that unit.
(2)
(a) Except for Dwellings with no electrical service, smoke detectors required by this
section shall be continuously powered by the house electrical service and shall be
interconnected so that activation of one detector will cause activation of all detectors.
Note: Wireless interconnectivity is permitted under this paragraph.
(b) Dwellings with no electrical service shall be provided with battery-powered smoke
detectors in the locations under sub. (1). Interconnection and battery-backup are not
required in these Dwellings.
(3) For family living units with one or more communicating split levels or open adjacent
levels with less than 5 feet of separation between levels, one smoke detector on the upper
level shall suffice for an adjacent lower level, including Basements. Where there is an
intervening door between one level and the adjacent lower level, smoke detectors shall be
installed on each level.
(4) Smoke alarms and detectors shall be maintained in accordance with the manufacturer's
specifications.
(5) For envelope Dwellings, at least 3 smoke alarms shall be placed in the air passageways.
The alarms shall be placed as far apart as possible.
(6) In Basements where two required Exits are separated by a continuous wall, a smoke
detector shall be placed on each side of the wall within 21 feet of each Exit.
SPS 321.095 Automatic fire sprinklers.
(1) Except as provided in subs. (2) and (3), the design, installation, testing and maintenance
of automatic fire sprinklers shall conform to NFPA 13D.
(2)
(a) The requirements of NFPA 13D sections 6.3 (4), 8.1.3 and 8.6 are not included as part
of this Code.
(b) Fire department connections are prohibited in multipurpose piping systems.
(3)
(a) Limited area automatic fire sprinkler systems are allowed in Dwellings.
(b)
1. A limited area automatic fire sprinkler system shall add the following wording to
the warning sign required in 6.3(5) of NFPA 13D: “The number and location of
sprinklers in this system does not conform to NFPA 13D."
2. An automatic fire sprinkler system providing fire protection throughout the
Dwelling in accordance with NFPA 13D shall add the following wording to the
warning sign required in 6.3(5) of NFPA 13D: “The number and location of sprinklers
in this system conform with NFPA 13D."
Note: Multipurpose piping systems need to conform to provisions of the
Plumbing Code, chs. SPS 381 to 387. These systems attach fire sprinkler heads to
the Dwelling's potable water piping system.
SPS 321.097 Carbon monoxide detectors.
(1) DEFINITIONS. In this section:
(ag) “Carbon monoxide detector” means an electronic or battery-operated device or
system that sounds an alarm when an unsafe level of carbon monoxide is in the air.
(ar) “Fuel-burning appliance" means a device that burns fossil fuel or carbon-based fuel
and that produces carbon monoxide as a combustion by-product. Fuel-burning appliances
include Stoves, ovens, grills, clothes dryers, furnaces, boilers, water heaters, fireplaces,
and heaters.
(2) NEW CONSTRUCTION.
(a) General. Listed and labeled carbon monoxide detectors shall be installed and
maintained in accordance with this Code, in one and 2-family Dwellings, for which
building permit applications were made or construction commenced prior to the adoption
of this Code.
(b) Location.
1. On floor levels that contain one or more sleeping areas, a carbon monoxide detector
shall be installed outside of the sleeping area, within 21 feet of the centerline of the
door opening to any sleeping area and in an Exit path from any sleeping area.
2. On floor levels that do not contain a sleeping area, a carbon monoxide detector shall
be installed in a common area on each floor level.
(c) Electrical service and interconnection.
1. Except as provided in subd. 2., carbon monoxide detectors shall be continuously
powered by the house electrical service, shall have a backup power supply and shall be
interconnected so that activation of one alarm will cause activation of all alarms.
2. Dwellings with no electrical service shall be provided with battery-powered carbon
monoxide detectors in the locations under par. (b). Interconnection is not required in
these Dwellings.
(d) Standards. The devices shall conform with one of the following standards:
1. Carbon monoxide detectors shall be listed and labeled identifying conformance with
UL 2034.
Note: Pursuant to this subdivision, carbon monoxide detectors need to be
acceptable under the 2005 edition of the UL 2034 standard, Single and Multiple
State Carbon Monoxide Alarms.
2. Carbon monoxide detectors and sensors as part of a gas detection or emergency
signaling system shall be listed and labeled identifying conformance with UL 2075.
Note: Pursuant to this subdivision, carbon monoxide detectors and sensors need
to be acceptable under the 2007 edition of the UL 2075 standard, Gas and Vapor
Protectors and Sensors.
(3) EXISTING DWELLINGS. Listed and labeled carbon monoxide detectors shall be installed
and maintained in accordance with this Code, in one and 2-family Dwellings, for which
building permit applications were made or initial construction commenced prior to the
adoption of this Code.
Note: See statutory reprint under SPS 321.097 (2) (a).
SPS 321.10 Protection against decay and termites.
(1) Wood used in any of the applications under this section shall meet all of the following
requirements:
(a) The wood shall be labeled and pressure treated with preservative in accordance with
an AWPA standard or shall be naturally durable and decay-resistant or shall be
engineered to be decay resistant.
(b) The wood shall be pressure treated with preservative or shall be naturally termiteresistant unless additional steps are taken to make the wood termite-resistant.
(2) Wood used in the following locations shall be as required under sub. (1):
(a) Resting directly upon or embedded in earth.
(b) Floor joists or sleepers that meet all of the following conditions:
1. The joists or sleepers are protected from the weather.
2. The joists or sleepers are within 18 inches above a lower floor surface, Deck, or
soil.
3. There is no vapor retarder that meets the requirements under SPS 322.38 (1)
(a) between the joists or sleepers and the soil below.
Note: This situation could occur with a floor over a crawl space or when a floor is
added over a patio Deck or a Garage slab.
(c) Floor joists exterior to the Dwelling that are within 18 inches above exterior grade,
unless protected with a moisture barrier.
Note: Acceptable moisture barriers for this application include ¾ -inch exterior
preservative-treated plywood, or ice dam protection material listed as meeting the
requirements of ASTM D 1970 or vapor retarder material, provided they are protected
from physical and UV light damage.
(d) Girders that span directly over and within 12 inches of earth.
(e) Sills and rim joists that rest on concrete or masonry and are also below grade or
within 8 inches above final exterior grade.
(f)
1. Siding and sheathing in contact with concrete, masonry, or earth and within 6 inches
above final exterior grade.
2. Siding and sheathing in contact with concrete or masonry and within 2 inches above
an impervious surface.
(g) Ends of wood structural members and their shims resting on or supported in masonry
or concrete walls and having clearances of less than ½ inch on the top, sides and ends.
(h) Bottom plates or sole plates of walls that rest on concrete or masonry and that are
below exterior grade or less than 8 inches above final exterior grade.
(i) Columns in direct contact with concrete or masonry unless supported by a structural
pedestal or plinth block at least one inch above the floor.
(j) Any structural part of an outdoor Deck, including the Decking.
(k) Permanent wood Foundations.
(3) Wood girders that rest directly on exterior concrete or masonry shall be protected by one
of the following methods:
(a) The wood shall be pressure treated with preservative or shall be a naturally durable
and decay-resistant species.
(b) Material, such as pressure-treated plywood, flashing material, steel shims, or waterresistant membrane material shall be placed between the wood and the concrete or
masonry.
(4) All pressure-treated wood and plywood shall be identified by a quality mark or certificate
of inspection of an Approved inspection agency which maintains continued supervision,
testing and inspection over the quality of the product.
Note: Heartwood of redwood, cypress, black walnut, catalpa, chestnut, sage orange, red
mulberry, white oak, or cedar lumber are considered by the Department to be naturally
decay-resistant. Heartwood of bald cypress, redwood, and eastern red cedar are
considered by the Department to be naturally termite resistant.
(5) FASTENERS.
(a) Fasteners for pressure-preservative treated wood and fire-retardant-treated wood shall
meet one of the following requirements:
1. The fastener is a steel bolt with a diameter of 0.5 inch or greater.
2. The fastener is made of stainless steel.
3. The fastener is made of hot-dipped, zinc-galvanized steel with the coating weight
and thickness labeled as complying with ASTM A 153.
4. The fastener is made of steel with a mechanically deposited zinc coating labeled as
complying with ASTM B 695, Class 55 or greater.
5. The fastener has coating types and weights in accordance with the fastener
manufacturer's recommendations. In the absence of the manufacturer's
recommendations subd. 1., 2., 3., or 4. shall apply.
Note: “Zinc plated," “zinc coated," “chrome plated," etc., fasteners do not
necessarily comply with either of these standards.
(b) When a fastener is used with a hanger or other metal fixture, the fastener shall be of
the same material as the hanger or metal fixture.
Note: When separate pieces are in close contact, zinc corrodes rapidly in the presence
of plain steel. Zinc corrodes much more rapidly in the presence of stainless steel.
(c) For the purposes of this section, a fastener includes nails, screws, and bolts, along
with nuts and washers.
SPS 321.11 Foam plastic.
(1)
(a) General. Foam plastic insulation shall have a flame-spread rating of 75 or less and a
smoke-developed rating of 450 or less when tested in accordance with ASTM E-84.
(b) Thermal barrier. Except as provided in par. (c), foam plastic insulation shall be
separated from the interior of the Dwelling by one of the following thermal barriers:
1. ½ -inch gypsum wallboard.
2. ½ -inch nominal wood structural panel.
3. ¾ -inch sawn lumber with tongue-and-groove or lap joints.
4. 1-inch of masonry or concrete.
5. A product or material shown by an independent laboratory to limit the temperature
rise on the unexposed surface to 250°F for 15 minutes when tested in accordance with
ASTM E-119.
6. For doors only, sheet metal with a minimum thickness of 26 standard steel gauge or
aluminum with a minimum thickness of 0.032 inch.
Note: Number 26 standard steel gauge is approximately equal to 0.018-inch.
(c) Exemptions from thermal barrier requirement. The following applications of foam
plastic do not require a thermal barrier:
1. On overhead Garage doors.
2. In the box sill of the Basement or Ground Floor, above the bottom of the floor
joists.
(2) Insulation that does not meet the requirements of this section may be Approved by the
Department in accordance with SPS 320.18. Approval will be based on tests that evaluate
materials or products representative of actual end-use applications.
Note: See SPS 322.21 (3) for requirements for protecting foam plastic on the exterior of a
Dwelling.
SPS 321.115 Installation of elevators or dumbwaiters. Elevators or dumbwaiters serving
Dwelling Units shall comply with the requirements under ch. SPS 318.
Subchapter III — Excavations
SPS 321.12 Drainage.
(1) GRADE. The finished grade of the soil shall slope away from the Dwelling at a rate of at
least 1/2 inch per foot for at least 10 feet, except as provided in subs. (2) and (3).
(2) OTHER SURFACES. Where the finished surface is impervious, it shall slope away from
the Dwelling for at least 10 feet at a rate that ensures equivalent drainage.
(3) OBSTRUCTIONS. Where lot lines, walls, slopes, or other barriers prevent having the 10foot distance in sub. (2), swales or other means shall be provided to ensure equivalent
drainage away from the Dwelling.
SPS 321.125 Erosion control and sediment control.
(1) GENERAL.
(a) Where Land Disturbing Construction Activity is to occur Erosion and sediment
Control Practices shall be employed, as necessary, and maintained to prevent or reduce
the potential deposition of soil or sediment to all of the following:
1. The Waters of the State.
2. Adjacent properties.
(b) Land disturbing construction activities, except those activities necessary to implement
Erosion or sediment Control Practices, may not begin until the sediment Control
Practices are in place for each area to be disturbed in accordance with the Approved plan.
(c) Erosion and sediment Control Practices shall be maintained until the disturbed areas
are Stabilized. A disturbed area shall be considered Stabilized by vegetation when a
perennial cover has been established with a density of at least 70%.
(d) Erosion and sediment Control Practices must be Approved by the Department.
(2) MANDATED PRACTICES. Specific practices at each site where Land Disturbing
Construction Activity is to occur shall be utilized to prevent or reduce all of the following:
(a) The deposition of soil from being tracked onto streets by vehicles.
(b) The discharge of sediment from disturbed areas into on-site storm water inlets.
(c) The discharge of sediment from disturbed areas into abutting Waters of the State.
(d) The discharge of sediment from drainage ways that flow off the site.
(e) The discharge of sediment by dewatering activities.
(f) The discharge of sediment eroding from soil stockpiles existing for more than 7 days.
(3) CONTROL STANDARDS. Including the practices under sub. (2), additional Erosion and
sediment Control Practices shall be employed, as necessary, to accomplish one of the
following:
(a) A potential annual cumulative soil loss rate of not more than one of the following:
1. Five tons per acre per year where sand, loamy sand, sandy loam, loam, sandy clay
loam, clay loam, sandy clay, silty clay, or clay textures are exposed.
2. Seven and 1/2 tons per acre per year where silt, silty clay loam, or silt loam textures
are exposed.
(c) A reduction of at least 40% of the potential sediment load in storm water runoff from
the site on an average annual basis as compared with no sediment or Erosion controls for
the site where less than one acre of Land Disturbing Construction Activity is to occur.
Note: See ch. SPS 325 Appendix A for further explanatory material regarding
compliance solutions for 80 and 40% reductions.
(4) SOIL LOSS ANALYSIS. Potential soil loss shall be determined using an engineer analytical
modeling acceptable to the Department.
Note: The Revised Universal Soil Loss Equation II is an example of an acceptable model
to determine soil loss.
(5) MONITORING.
(a) The Owner or Owner's agent shall check the Erosion and sediment Control Practices
for maintenance needs at all the following intervals until the site is Stabilized:
1. At least weekly.
2. Within 24 hours after a rainfall event of 0.5 inches or greater. A rainfall event shall
be considered to be the total amount of rainfall recorded in any continuous 24-hour
period.
3. At all intervals cited on the Erosion and sediment control plan.
(b) The Owner or Owner's agent shall maintain a monitoring record when the Land
Disturbing Construction Activity involves one or more acres.
(c) The monitoring record shall contain at least the following information:
1. The condition of the Erosion and sediment Control Practices at the intervals
specified under par. (a).
2. A description of the maintenance conducted to Repair or replace Erosion and
sediment Control Practices.
(6) MAINTENANCE.
(a)
1. Except as provided in subd. 3., off-site sediment deposition resulting from the
failure of an Erosion or sediment Control Practice shall be cleaned up by the end of
the next day.
Note: Contact the Land and Natural Resources Division before attempting to
clean up any sediment deposited or discharged into the Waters of the State.
2. Except as provided in subd. 3., off-site soil deposition, resulting from construction
activity, that creates a nuisance shall be cleaned up by the end of the workday.
3. A municipality may enact more stringent requirements regarding cleanup of soil or
sediment deposition onto public ways.
(b)
1. Except as required in subd. 2., the Owner or Owner's agent shall complete Repair or
replacement of Erosion and sediment Control Practices as necessary within 48 hours
of an interval specified under sub. (5).
2. When the failure of Erosion or sediment Control Practices results in an immediate
threat of sediment entering public sewers or the Waters of the State, procedures shall
be implemented immediately to Repair or replace the practices.
Note: See ch. SPS 325 Appendix A for further explanatory material.
SPS 321.13 Excavations adjacent to adjoining property.
(1) NOTICE. Any person making or causing an excavation which may affect the lateral soil
support of adjoining property or buildings shall provide at least 30 days written notice to all
Owners of adjoining buildings of the intention to excavate. The notice shall state that
adjoining buildings may require permanent protection.
(a) Exception. The 30-day time limit for written notification may be waived if such
waiver is signed by the owner(s) of the adjoining properties.
(2) RESPONSIBILITY FOR UNDERPINNING AND FOUNDATION EXTENSIONS.
(a) Excavations less than 12 feet in depth. If the excavation is made to a depth of 12 feet
or less below grade, the person making or causing the excavation shall not be responsible
for any necessary underpinning or extension of the Foundations of any adjoining
buildings.
(b) Excavations greater than 12 feet in depth. If the excavation is made to a depth in
excess of 12 feet below grade, the Owner(s) of adjoining buildings shall be responsible
for any necessary underpinning or extension of the Foundations of their buildings to a
depth of 12 feet below grade. The person making or causing the excavation shall be
responsible for any underpinning or extension of Foundations below the depth of 12 feet
below grade.
SPS 321.14
Excavations for footings and Foundations.
(1) EXCAVATIONS BELOW FOOTINGS AND FOUNDATIONS. No excavation shall be made
below the footing and Foundation unless provisions are taken to prevent the collapse of the
footing or Foundation.
(2) EXCAVATIONS FOR FOOTINGS. All footings shall be located on undisturbed or
compacted soil, free of organic material, unless the footings are reinforced to bridge poor soil
conditions.
Subchapter IV — Footings
SPS 321.15 Footings.
(1) GENERAL.
(a) The Dwelling and Attached structures, such as Decks and Garages, shall be supported
on a structural system designed to transmit and safely distribute the loads to the soil.
(b) The loads for determining the footing size shall include the weight of the Live Load,
roof, walls, floors, pier, or column, plus the weight of the structural system and the soil
over the footing.
(c) Footings shall be sized to not exceed the allowable material Stresses.
(d) The bearing area shall be at least equal to the area required to transfer the loads to the
supporting soil without exceeding the bearing capacity of the soil.
(e)
1. Structures supported on floating slabs or similar shallow Foundations may not be
physically attached to structures that are supported by footings that extend below the
frost line unless an isolation joint is used between the structures, except as provided in
subd. 2. This isolation shall extend for the full height of the structure.
2. Exterior ramps are not required to comply with subd. 1.
(2) SIZE AND TYPE. Unless designed by structural analysis, unreinforced concrete footings
shall comply with the following requirements:
(a) Continuous footings. The minimum width of the footing on each side of the
Foundation wall shall measure at least 4 inches wider than the wall. The footing depth
shall be at least 8 inches nominal. Footing placed in unstable soil shall be formed. Lintels
may be used in place of continuous footings when there is a change in footing elevation.
Note: Unstable soil includes soils that are unable to support themselves at a 90-degree
angle for the full depth of the footing.
(b) Column or pier footing.
1. The minimum width and length of column or pier footings shall measure at least 2
feet by 2 feet.
2. The minimum depth of column or pier footings shall measure at least 12 inches
nominal.
(c) Trench footings. Footings poured integrally with the wall may be used when soil
conditions permit. The minimum width shall be at least 8 inches nominal.
(d) Chimney and fireplace footings. Footing for Chimneys or fireplaces shall extend at
least 4 inches on each side of the Chimney or fireplace. The minimum depth shall
measure at least 12 inches nominal.
(e) Floating slabs. Any Dwelling supported on a floating slab on grade shall be designed
through structural analysis.
(f) Deck footings. Decks attached to Dwellings and detached Decks which serve an Exit
shall be supported on a structural system designed to transmit and safely distribute the
loads to the soil. Footings shall be sized to not exceed the allowable material Stresses.
The bearing area shall be at least equal to the area required to transfer the loads to the
supporting soil without exceeding the bearing values of the soil.
(3) SOIL-BEARING CAPACITY. No footing or Foundation shall be placed on soil with a
bearing capacity of less than 2,000 pounds per square foot unless the footing or Foundation
has been designed through structural analysis. The soil-bearing values of common soils may
be determined through soil identification.
Note: The Department will accept the soil-bearing values for the types of soil listed in
the following table: - See PDF for table
(a) Minimum soil-bearing values. If the soil located directly under a footing or
Foundation overlies a layer of soil having a smaller allowable bearing value, the smaller
soil-bearing value shall be used.
(b) Unprepared fill material, organic material. No footing or Foundation shall be placed
upon unprepared fill material, organic soil, alluvial soil, or mud unless the load will be
supported. When requested, soil data shall be provided.
Note: The decomposition of organic material in landfill sites established for the
disposal of organic wastes may produce odorous, toxic, and explosive concentrations
of gas which may seep into buildings through storm sewers and similar underground
utilities unless provisions are taken to release the gases to the atmosphere.
ID
SPS 321.16 Frost protection.
(1) GENERAL.
(a) Footings and Foundations, including those for Landings and stoops, shall be placed
below the frost penetration level or at least 48 inches below adjacent grade, whichever is
deeper, except as allowed under sub. (2).
(b) Footings may not be placed on frozen material.
(2) EXCEPTIONS.
(a) Frost protected shallow Foundations shall be designed in accordance with ASCE–32
as adopted in Table 320.24-5.
(b) Portions of footings or Foundations located directly under Window areaways do not
require frost protection provided the rest of the Foundation is protected in accordance
with this section.
(c) Footings and Foundations may bear directly on bedrock less than 48 inches below
adjacent grade provided all of the following conditions are met.
1. The rock shall be cleaned of all earth prior to placement.
2. All clay in crevices of the rock shall be removed to the level of frost penetration or
to 1.5 times the width of the rock crevice, whichever is less.
3. Provisions shall be taken to prevent water from collecting anywhere along the
Foundation.
(d) Subsection (1) (a) does not apply to the footing for a ramp and its Handrail posts
unless the ramp abuts a frost-protected stoop or Landing, in which case only the footing
for that abutting end of the ramp is required to have the frost protection under sub. (1) (a),
such as by bearing onto the stoop or Landing, so that a tripping hazard is not created.
Note: See ch. SPS 325 Appendix A for further information.
SPS 321.17 Drain tiles.
(1) DETERMINATION OF NEED.
(a) New construction.
1. Except as provided under sub. (2), a complete drain tile or pipe system shall be
installed around the Foundation of Dwellings under construction where groundwater
occurs above the bottom of the footing.
2. For the purposes of this section, a complete drain tile or pipe system includes all of
the following:
a. The drain tile or pipe installed inside and outside the Foundation, except as
allowed under SPS 321.17 (3) (d) 1. b.
b. Bleeders connecting the inside tile or pipe to the outside tile or pipe.
c. The sump pit or crock.
d. The discharge piping.
e. A pump or other means of discharging water to grade.
(b) Optional systems.
1. If a complete drain tile or pipe system is not required by natural conditions under
par. (a) or by the Department, a partial drain tile or pipe system may be installed.
2. For the purposes of this section, a partial drain tile or pipe system includes a means
of discharging water from the tile or pipe and may include any of the other elements
under par. (a) 2.
Note: Means of discharging water include a sump pit, a crock, or natural means of
drainage to daylight.
(2) OPTIONAL SYSTEMS.
(a) New construction.
1. For new Dwelling construction, the Department may determine the soil types and
natural or seasonal groundwater levels for which a complete drain tile or pipe system
is required.
(3) MATERIAL AND INSTALLATION REQUIREMENTS FOR REQUIRED SYSTEMS.
(a) General. Complete drain tile or pipe systems required by natural conditions under
sub. (1) (a) or by the Department shall comply with the requirements of this subsection.
(b) Basement floor slabs. The Basement slab shall be placed on at least 4 inches of clean
graded sand, gravel, or crushed stone.
(c) Manufactured drainage systems. Manufactured drainage systems not meeting the
requirements of this section shall be submitted to the Department for review and approval
prior to installation.
(d) Drain tile or pipe installation. Drain tile or pipe used for Foundation drainage shall
comply with the following requirements:
1.
a. Except as allowed under subd. 1. b., the top of the tile or pipe shall be at or
below the top of the footing.
b. Where the top of the footing is more than 4 inches below the bottom of the
floor slab, tile or pipe is required on the interior of the Foundation only and it
shall be placed directly under the floor.
Note: This situation will commonly occur with a walk-out Basement.
2. Drain tile or pipe shall have an inside diameter of at least 3 inches.
3. Drain tile or pipe shall have open seams, joints, or perforations to allow water to
enter.
4. Where individual tiles are used, they shall be laid with 1/ 8-inch open joints. Joints
between tiles shall be covered with a strip of asphalt or tar impregnated felt.
5. The tile or pipe shall be placed upon at least 2 inches of Coarse Aggregate and shall
be covered on the top and the side facing away from the Dwelling with at least 12
inches of Coarse Aggregate that meets all of the following criteria:
a. 100% of the aggregate shall pass a 1-inch sieve.
b. 90-100% of the aggregate shall pass a ¾-inch sieve.
c. 0-55% of the aggregate shall pass a 3/8-inch sieve.
d. 0-5% of the aggregate shall pass a #8 sieve.
Note: A #8 sieve has square openings of 2.36 mm or 0.09 inch.
Note: These specifications encompass aggregate sizes #6 and #67 per ASTM
standard C 33. Of the two sizes, #6 is coarser.
6.
a. Bleeder tiles or pipes shall be provided at no more than 8-foot intervals to
connect the exterior drain tile or pipe to the interior drain tile or pipe.
b. Bleeder tiles or pipes shall have a minimum interior diameter of 3 inches.
c. Direct connection of the bleeders is not required if the intersection of the
bleeder with the tile or pipe is covered with a membrane or fabric that prevents
soil and fines from entering the system.
7. The drain tiles or pipe that lead from the footing tiles to the sump pit shall be laid at
a grade of at least 1/8 inch per foot leading to the sump pit. The remaining drain tiles
or pipe shall be level or graded downward to the line leading to the sump pit.
(e) Drain tile or pipe discharge.
1. Drain tiles or pipe shall be connected to the sump pit.
2. The sump pit shall discharge to natural grade or be equipped with a pump.
3. All other aspects of drain tile discharge shall be in accordance with this Code.
SPS 321.18 Foundations.
(1) GENERAL.
Subchapter V — Foundations
(a) Design. Foundation walls shall be designed and constructed to support the vertical
loads of the Dwelling, lateral soil pressure, and other loads without exceeding the
allowable Stresses of the materials of which the Foundations are constructed.
(b) Lateral support at base. Lateral support such as floor slabs or framing shall be
provided at the base of Foundation walls.
(c) Lateral support at top. Lateral support shall be provided at the top of the Foundation
walls by one of the following:
2. Structural analysis. A system designed through structural analysis.
3. Anchor bolts.
a. Structural steel anchor bolts, at least 1/2 inch in diameter, embedded at least 7
inches into the concrete or grouted masonry with a maximum spacing of 72
inches and located within 18 inches of wall corners.
b. A properly sized nut and washer shall be tightened on each bolt to the plate or
sill.
c. When vertical-reinforcing steel is provided in masonry construction, as required
under sub. (3), the location requirements under subd. 3. a. shall be modified as
necessary so anchor bolts are placed in the same core as the reinforcement
without exceeding the limits of subd. 3. a.
d. Alternate Foundation anchorage, designed and spaced in accordance with
structural analysis and as required to provide equivalent anchorage to the
requirements of subd. 3. a., is allowable.
4. Other mechanical fasteners.
a. Mechanical fasteners used in accordance with the manufacturer's testing and
listing.
b. When vertical-reinforcing steel is provided in masonry construction, as
required under sub. (3), the location requirements under subd. 4. a. shall be
modified as necessary so the fasteners are placed in the same core as the
reinforcement without exceeding the limits of subd. 4. a.
(d) Floor framing.
1. Floor framing shall be fastened to the sill plate by one of the following methods:
a. Mechanical fasteners used in accordance with the manufacturer's testing and
listing.
b. In accordance with structural analysis.
c. In accordance with the fastener table printed in Ch. SPS 325 Appendix A.
Note: Per SPS 321.22 (1), sill plates are not required on Foundation walls of
poured concrete or on masonry walls with mortar or grout filled cores or on
masonry walls with a solid block top course.
2.
a. Where the floor framing is parallel to the Foundation wall, solid blocking or
bridging shall be installed in at least the first adjacent joist space at a spacing of
no more than 32 inches on center.
b. Blocking and bridging shall be the same depth as the joist.
c. Fastening of the blocking or bridging shall be in accordance with structural
analysis or the fastener schedule in Table 321.02-2.
Note: The floor-framing elements required in this section are intended to
provide lateral support to the top of the Foundation wall. See SPS 321.22
(9) for further requirements relating to floor framing, including for bridging of
floor framing to provide restraint against rotation or lateral displacement of the
floor framing.
(e) Soil lateral load. Unless designed through structural analysis, soil lateral loads shall
be determined from Table 321.18-A. - See PDF for table
(2) CONCRETE FOUNDATION WALLS.
(a) General structural requirements. Except as provided in par. (b), unless designed
through structural analysis, the minimum thickness of concrete Foundation walls shall be
determined from Table 321.18-B, but in no case shall the thickness of the Foundation
wall be less than the thickness of the wall it supports.
(b) Equalized loading. A 6-inch nominal wall thickness may be used provided the fill on
one side of the wall is within 12 inches vertically of the fill on the other side of the wall.
Note: See SPS 321.15 (1) (c) for trench footing requirements. - See PDF for table
(3) MASONRY FOUNDATION WALLS.
(a) Damp proofing.
1. Except as allowed under subd. 3., masonry block Foundation walls shall be coated
with a layer of minimum 3/ 8-inch-thick type M or S portland cement mortar parging
on the exterior of the wall from footing to finished grade.
2. Masonry Foundation walls shall be damp-proofed by applying to the exterior
surface of the portland cement parging from footing to finished grade, a continuous
coating of one of the following:
a. A bituminous coating applied in accordance with the manufacturer's
instructions.
b. Acrylic-modified cement applied at a minimum rate of 3 pounds per square
yard.
c. A layer of minimum 1/8-inch-thick structural surface bonding material labeled
as complying with ASTM C887.
Note: The ASTM C887 standard is entitled, “Standard Specification for
Packaged, Dry, Combined Materials for Surface Bonding Mortar."
3.
d. A waterproofing treatment applied in accordance with the manufacturer's
instructions.
a. Parging of masonry block Foundation walls is not required where a damp
proofing material is sufficiently flexible to be listed or designed for direct
application to masonry block.
b. Parging of masonry block Foundation walls is not required where a layer of
minimum ¼-inch thick structural surface bonding material labeled as complying
with ASTM C887 is used for damp proofing.
(b) Structural requirements. Unless designed through structural analysis, the masonry
Foundation walls shall be constructed in accordance with ACI 530.1 and the following
requirements:
1. The minimum thickness of unreinforced masonry Foundation walls shall be
determined by Table 321.18-C, but in no case shall the thickness be less than the
thickness of the wall it supports.
2. Reinforced masonry walls shall be reinforced in accordance with the requirements
of Tables 321.18-D, 321.18-E or 321.18-F. Vertical reinforcement shall be provided
on each side of any opening and at intervals indicated in the appropriate table. - See
PDF for table
- See PDF for table
- See PDF for table
- See PDF for table
3. Vertical reinforcement shall have a minimum yield strength of 60,000 psi.
4. Solid-grouted Hollow Units or cores containing vertical reinforcement shall be
filled with masonry grout that complies with ASTM C 476.
5. In lieu of the reinforcement provisions of Tables 321.18-D, 321.18-E and 321.18-F,
alternative reinforcing bar size and spacing having an equivalent cross-sectional area
or reinforcement per linear foot of wall is permitted, provided the spacing of the
reinforcement does not exceed 72 inches and reinforcing bar size does not exceed No.
11.
6. The depth below grade, wall height and reinforcement spacing may exceed the
maximum values indicated in Tables 321.18-D, 321.18-E and 321.18-F only if the
design is based on structural analysis.
(4) WOOD FOUNDATIONS. Wood Foundations shall be designed and constructed in
accordance with the wood-Foundation standard adopted in Table 320.24-6m.
Note: The Department will accept Permanent Wood Foundations Design and
Construction Guide published by the Southern Forest Products Association through the
Southern Pine Council, as complying with this standard. The Design and Construction
Guide requires a 3.5-inch-thick floor slab if a poured concrete floor slab is used.
ID
tri
ID
ID
Subchapter VI — Floors
SPS 321.19 Floor design. Floors shall support all Dead Loads plus the minimum unit Live
Loads as set forth in SPS 321.02. The Live Loads shall be applied to act vertically and uniformly
to each square foot of horizontal floor area. Basements shall be provided with wood or concrete
or similar type floors that comply with SPS 321.20 or 321.205.
SPS 321.20 Concrete floors.
(1) When concrete floors are provided, the thickness of the concrete shall measure at least 3
inches.
(2) When a concrete floor is placed in clay soils, a 4-inch-thick base course shall be placed in
the subgrade consisting of clean graded sand, gravel, or crushed stone.
(3) When a concrete floor is placed on sand or gravel soils, the base course may be omitted
unless drain tile is installed. If drain tile is installed, the requirements of SPS 321.17 shall be
met.
SPS 321.203 Garage floors.
(1) MATERIALS. Garage floors shall be constructed of concrete or other noncombustible
materials which are impermeable to petroleum products. Slab-on-grade concrete Garage
floors shall be at least 4 inches thick and placed over at least 4 inches of granular fill.
Note: It is not the intent of sub. (1) to require a concrete floor to be sealed to make it
completely impermeable.
(2) CONFIGURATION. The floor shall be sloped such that water is removed in accordance
with one of the following:
(a) Water drains toward the overhead door or to exterior grade such that no damage will
be caused to any structural member or wall covering of the Garage or the Dwelling.
(b) Water drains into an interior floor drain that complies with the requirements of
ch. SPS 382.
Note: See SPS 382.34 for floor drain requirements.
SPS 321.205 Wood floors in contact with the ground. Wood floors in contact with the
ground shall comply with the requirements under SPS 321.18 (4).
SPS 321.21 Precast concrete floors. Precast concrete floors shall be designed through
structural analysis, or load tables furnished by the precast product fabricator may be used,
provided the load tables were developed using structural analysis or load testing.
SPS 321.22 Wood frame floors. Unless designed through structural analysis, wood frame
floors shall comply with the following requirements:
(1) FLOOR JOISTS.
(a) General.
1. Floor joists shall comply with the structural requirements and Live Load
determination under SPS 321.02.
Note: See Ch. SPS 325 Appendix A for design information.
2. Where the joists of a floor system are parallel to, and located between bearing walls
above and below, the joists shall be doubled.
(b) Floor joists on concrete walls. Where a sill plate is provided for floor joists on
poured concrete, the sill plates shall be fastened to the Foundation.
Note: Section SPS 321.18 (1) (d) requires the floor joists to also be fastened to the sill
plate.
(c) Floor joists on masonry walls with a solid top course. Where a sill plate is provided
for floor joists on solid block top course masonry, the sill plate shall be fastened to the
Foundation.
(d) Floor joists on masonry walls with open top course.
1. Where the masonry wall has an open top course, a sill plate at least as wide as the
Foundation wall shall be fastened to the Foundation.
2. Where anchor bolts are used on masonry walls with an open top course, the
minimum width of an individual piece making up the sill plate shall be at least 5.5
inches.
Note: A sill plate can be made of multiple pieces to achieve the full width.
(2) FLOOR TRUSSES. Metal plate connected wood floor trusses shall be designed in
accordance with the Design Specifications for Metal Plate Connected Parallel Chord Wood
Trusses and the National Design Specification for Wood Construction. Truss members shall
not be cut, bored, or notched.
(3) GIRDERS AND BEAMS.
(a) Girders and beams shall be selected from Table 321.22-A1 or Table 321.22-A2 or
shall be designed through structural analysis.
(b) Wood girders and beams shall be fitted at the post or column. Adjoining ends shall be
fastened to each other to transfer horizontal loads across the joint. Beams shall also be
fastened to the posts with framing anchors, angle clips, or equivalent.
(c) Where intermediate beams are used, they shall rest on top of the girders; or shall be
supported by ledgers or blocks fastened to the sides of the girders; or they may be
supported by Approved metal hangers into which the ends of the beams shall be fitted.
(d) Lateral restraint for all wood beams shall be provided at all columns using a saddle or
other Approved connection where the beam meets one of the following conditions:
1. The beam is not restrained at both ends.
2. The beam is more than 11.25 inches deep using actual measurement.
Note: A saddle supports the beam on the bottom and allows for the throughconnection of fasteners into the side of the beam.
(4) BEARING AND END CONFIGURATION.
(a) Sawn lumber.
1. `Joists.' Wood joists made of sawn lumber shall meet the following bearing
requirements:
a. Wood joists supported on wood or metal shall have a bearing surface of at least
1½-inches measured from the end of the joist.
b. Wood joists supported on masonry or concrete shall have a bearing surface of
at least 3 inches measured from the end of the joist.
c. The tail end of a floor joist may not extend past the edge of a beam by more
than the depth of the floor joist.
d. Wood floor joists with ends that intersect over a beam shall have the ends
overlap at least 3 inches and be securely fastened together with at least two 12d
common nails or the ends shall be butt-jointed or face-jointed and fastened with
ties, straps, plates, or solid blocking.
2. `Beams and girders.' Beams and girders made of sawn lumber shall have a bearing
surface on their supports of at least 3 inches parallel to the beam or girder and be at
least as wide as the beam or girder.
(b) Engineered wood products. Bearing surface for engineered wood products shall be in
accordance with the manufacturer's instructions provided those instructions were
developed through structural analysis or product testing and are applicable to the
configuration.
(5) NOTCHING AND BORING. Notching and boring of beams or girders is prohibited unless
determined through structural analysis.
(a) Notching of floor joists.
1. Notches located in the top or bottom of floor joists shall not have a depth
exceeding 1 /6 the depth of the joist, shall not have a length exceeding 1/3 the joist
depth nor be located in the middle 1/3 of the span of the joist.
2. Where floor joists are notched on the ends, the notch shall not exceed ¼ the depth
of the joist. Notches over supports may extend the full bearing width of the support.
(b) Boring of floor joists.
1. `General.' A hole may not be bored in a floor joist within 2 inches of a notch or
another hole. In no case shall the distance between adjacent holes be less than the
diameter of the larger hole.
2. `Holes near the edge.' Holes bored in the top or bottom 2 inches of a joist shall
follow the limitations for notching under par. (a).
3. `Other holes.' Holes bored in floor joists that are not within 2 inches of the top or
bottom of the joist shall have their diameter limited to 1/3 the depth of the joist.
(c) Engineered wood products. Notching or boring of engineered wood products shall be
done in accordance with the manufacturer's instructions provided those instructions were
developed through structural analysis or product testing.
(6) OVERHANG OF FLOORS.
(a) General. Except as provided in pars. (b) and (c), a floor joist overhang shall be
cantilevered beyond the outer edge of the supporting wall below it by no more than the
actual depth of the joist or shall be designed through structural analysis in accordance
with SPS 321.02 (3).
(b) Joist overhangs parallel to the main floor framing system. Joist overhangs that are
extensions of, and parallel to, the main floor framing system may extend beyond the
depth of the joist without structural analysis provided they meet all of the following
conditions:
1. The overhang is cantilevered no more than 2 feet beyond the outer edge of the
supporting wall below it.
2.
a. The overhang supports a uniform load limited to the weight of the bearing wall
and the tributary roof area above it.
b. The tributary length of the roof area, excluding the eave overhang, is no more
than 2 feet greater than the actual length of the joist directly below.
c. The eave overhang is no more than 2 feet.
Note: The tributary length is usually half the span of the joist or rafter.
3. The joist overhang does not support any concentrated loads. For the purposes of this
subsection, a framed opening in the wall with a rough opening of 4 feet or less shall be
considered uniform loading.
4.
a. The cantilevered joist is doubled at the supporting wall.
b. The doubled joist length extends inward beyond the inner edge of the
supporting wall by the same distance as the cantilever.
c. The added joist member is secured to the main joist as stated in the nailing
schedule in Ch. SPS 325 Appendix A, under the heading for “floor framing, builtup girder and beams, top loaded".
(c) Joist overhangs perpendicular to the main floor framing system. Joist overhangs
that are perpendicular to the main floor framing system, or lookout joists, may extend
beyond the depth of the joist without structural analysis provided they meet all of the
following conditions:
1. The joist overhang is cantilevered no more than 2 feet beyond the outer edge of the
supporting wall below it.
2.
a. A double floor joist is used to support the lookout joist.
b. The double floor joist is located a distance of at least 2 times the cantilever
length inward from the outer edge of the supporting wall below.
c. The lookout joists are fastened to the double joist with metal hangers.
3. The joist overhang supports no more than either a non-bearing wall or a wall that
supports only a roof which spans no more than the floor overhang cantilever length
plus the eave overhang.
(d) All overhangs longer than the depth of the supporting joist that do not meet all of the
conditions under par. (b) or (c) shall be designed through structural analysis.
(7) FLOOR OPENINGS. Trimmers and headers shall be