Energy Conservation Program for Consumer Products: Energy Conservation Standards for Central Air Conditioners and Heat Pumps

Federal RegisterNov 24, 1999

Ask Donna

What actually matters in this document.

Text

SUMMARY: The Department of Energy publishes this Supplemental Advance

Notice of Proposed Rulemaking (ANOPR) to consider amending the energy

conservation standards for central air conditioners and heat pumps.

The purpose of this Supplemental ANOPR is to provide interested

persons with an opportunity to comment on:

First, the product classes that the Department is planning to

analyze;

Second, the analytical framework, models (e.g., the Government

Regulatory Impact Model (GRIM)), and tools (e.g., a Monte Carlo

sampling methodology, and life-cycle cost (LCC) and national energy

savings (NES) spreadsheets) that the Department has been using in

performing analyses of the impacts of energy conservation standards;

Third, the results of preliminary analyses for the engineering,

LCC, payback and NES contained in the Preliminary Technical Support

Document (TSD): Energy Efficiency Standards for Consumer Products:

Central Air Conditioners and Heat Pumps and summarized in this

Supplemental ANOPR; and

Fourth, the candidate energy conservation standard levels that the

Department has developed from these analyses.

DATES: Written comments must be received by February 7, 2000. The

Department requests 10 copies of the written comments and, if possible,

a computer disk. The Office of Building Research and Standards is

currently using WordPerfect 8.

A public hearing will be held on December 9, 1999, from 9 am-5 pm.

See Section IV of the Supplementary Information for further details.

ADDRESSES: Written comments should be submitted to: U.S. Department of

Energy, Attn: Brenda Edwards-Jones, Office of Energy Efficiency and

Renewable Energy, ``Energy Efficiency Standards for Consumer

Products,'' (Docket No. EE-RM-94-403), EE-431, Forrestal Building, 1000

Independence Avenue, SW, Room 1J-018, Washington, DC 20585, (202) 586-

2945.

The public hearing will be held at the U.S. Department of Energy,

Forrestal Building, 1000 Independence Avenue SW, Room 1E-245,

Washington, DC 20585.

Copies of the Preliminary TSD: Energy Efficiency Standards for

Consumer Products: Central Air Conditioners and Heat Pumps may also be

obtained from: U.S. Department of Energy, Office of Building Research

and Standards, 1000 Independence Avenue, SW, Rm 1J-018, Washington,

D.C. 20585-0121, (202) 586-9127. The Preliminary TSD will also be

available through DOE's web site. The Preliminary TSD provides the

technical details of the analysis that was conducted in support of the

Supplemental ANOPR being issued today.

Public Information: The public may visit the Freedom of Information

Reading Room, located at the US Department of Energy, Forrestal

Building, 1000 Independence Avenue, SW, Room 1E-190, Washington, DC

20585 between the hours of 9 am and 4 pm, Monday through Friday,

(except Federal holidays). Call (202) 586-3142 for information.

For more information concerning public participation in this

rulemaking proceeding, see section IV, ``Public Comment Procedures,''

of this document.

FOR FURTHER INFORMATION CONTACT: Dr. Michael E. McCabe, U.S. Department

of Energy, Office of Energy Efficiency and Renewable Energy, Forrestal

Building, Mail Station EE-41, 1000 Independence Avenue, SW, Washington,

DC 20585-0121, (202) 586-0854, E-mail: Michael.E.McC[email protected].

Edward Levy, Esq., U.S. Department of Energy, Office of General

Counsel, Forrestal Building, Mail Station GC-72, 1000 Independence

Avenue, SW, Washington, DC 20585, (202) 586-9507, E-mail:

Edward.L[email protected].

SUPPLEMENTARY INFORMATION:

I. Introduction

A. Authority

B. Background

1. History

2. Process Improvement

3. Test Procedure

II. Central Air Conditioners and Heat Pumps Analyses

A. Preliminary Market and Technology Assessment

1. Market Assessment

a. General

b. Product Specific

2. Technology Assessment

a. General

b. Product Specific

3. Preliminary Baseline Shipments Forecast

a. General

b. Product Specific

B. Screening Analysis

1. Product Classes

a. General

b. Product Specific

2. Baseline Equipment

a. General

b. Product Specific

3. Technology Screening

a. General

b. Product Specific

C. Engineering Analysis

1. Energy Savings Potential and Production Costs

a. General

b. Product Specific

i. Efficiency-Level Approach

ii. Reverse Engineering Approach

iii. Design Option Approach

iv. Outside Regulatory Changes Affecting the Engineering

Analysis

2. Manufacturing Costs

a. General

b. Product Specific

i. Characterizing Uncertainty

ii. Variability in Costs Among Manufacturers

iii. Proprietary Design

D. Life-Cycle Cost (LCC) and Payback Analysis

1. LCC Spreadsheet Model

a. General

b. Product Specific

i. LCC Analysis

ii. Equipment Prices

iii. Payback Analysis (Distribution of Paybacks)

iv. Rebuttable Payback

2. Preliminary Results

a. General

b. Product Specific

E. Preliminary National Impact Analyses

1. National Energy Savings (NES) Spreadsheet Model

a. General

b. Product Specific

i. Inputs to NES Analysis

ii. Shipments Model

iii. National Net Present Value

2. Preliminary Results

a. General

b. Product Specific

3. Indirect Employment Impacts

a. General

b. Product Specific

F. Consumer Analyses

1. Consumer Sub-group Analysis

a. General

b. Product Specific

2. Consumer Participation

a. General

b. Product Specific

G. Manufacturer Impact Analysis

1. Industry Characterization (Phase 1)

a. General

b. Product Specific

2. Industry Cash Flow (Phase 2)

a. General

b. Product Specific

[[Page 66307]]

3. Manufacturer Sub-Group Analysis (Phase 3)

a. General

b. Product Specific

4. Interview Process

a. General

b. Product Specific

H. Competitive Impact Assessment

a. General

b. Product Specific

I. Utility Analysis

1. Proposed Methodology

a. General

b. Product Specific

J. Environmental Analysis

1. Proposed Methodology

a. General

b. Product Specific

K. Regulatory Impact Analysis

III. Proposed Standards Scenarios

IV. Public Comment Procedures

A. Participation in Rulemaking

B. Written Comment Procedures

C. Issues for Public Comment

V. Review Under Executive Order 12866 and other provisions

I. Introduction

A. Authority

Part B of Title III of the Energy Policy and Conservation Act, Pub.

L. 94-163, as amended by the National Energy Conservation Policy Act,

Pub. L. Law 95-619, the National Appliance Energy Conservation Act of

1987, Pub. L. 100-12, the National Appliance Energy Conservation

Amendments of 1988, Pub. L. 100-357, and the Energy Policy Act of 1992,

Pub. L. 102-486, (EPCA or the Act), created the Energy Conservation

Program for Various Consumer Products other than Automobiles. 42 U.S.C.

6291-6309.

The National Appliance Energy Conservation Act of 1987 amended EPCA

to impose performance standards for central air conditioners and heat

pumps as part of the energy conservation program for consumer products.

EPCA, section 325(d), 42 U.S.C. 6295 (d). EPCA also requires the

Department to publish final rules thereafter, to determine if these

standards should be amended.

Before the Department determines whether to adopt a proposed energy

conservation standard it must first solicit comments on the proposed

standard. EPCA, section 325 (p), 42 U.S.C. 6295 (p). Any new or amended

standard must be designed so as to achieve the maximum improvement in

energy efficiency that is technologically feasible and economically

justified. EPCA, section 325(o)(2)(A), 42 U.S.C. 6295 (o)(2)(A). To

determine whether economic justification exists the Department must

review comments on the proposal and determine that the benefits of the

proposed standard exceed its burdens based to the greatest extent

practicable, weighing the following seven factors:

(1) The economic impact of the standard on the manufacturers and on

the consumers of the products subject to such standard;

(2) The savings in operating costs throughout the estimated average

life of the covered product in the type (or class) compared to any

increase in the price, initial charges, or maintenance expenses for the

covered products that are likely to result directly from the imposition

of the standard;

(3) The total projected amount of energy savings likely to result

directly from the imposition of the standard;

(4) Any lessening of the utility or the performance of the covered

products likely to result from the imposition of the standard;

(5) The impact of any lessening of competition, as determined in

writing by the Attorney General, that is likely to result from the

imposition of the standard;

(6) The need for national energy conservation; and

(7) Other factors the Secretary considers relevant.

EPCA, Section 325(2)(B), 42 U.S.C. 6295(2)(B)

B. Background

1. History

The Energy Policy and Conservation Act, as amended (EPCA or Act),

requires the Department of Energy (DOE or Department) to consider

amending the energy conservation standards for certain major household

appliances. In 1992, the Department initiated engineering and LCC

studies for central air conditioners and heat pumps based on use of

computer simulation models. An ad hoc working group was formed to

advise the Department and to provide engineering and test data to use

with the computer models. The working group, which included

representatives from central air conditioner and heat pump

manufacturers, the Air Conditioning & Refrigeration Institute (ARI),

Lawrence Berkeley National Laboratory (LBNL), and Oak Ridge National

Laboratory (ORNL), also provided production cost data for establishing

the cost-effectiveness of the various design options selected for

study.

On September 8, 1993, the Department published an ANOPR (58 FR

47326 ) which discussed the number of product classes and design

options, the computer simulation models, and the methodologies which

the Department intended to use in its analysis of increased energy

efficiency standards for central air conditioners and heat pumps. After

the ANOPR was issued, the Department continued its analysis of LCCs,

payback periods, and preliminary NES which were shared with

representatives from the air-conditioning industry.

In 1995, the Department abandoned the approach of using computer

simulation models as a result of concerns expressed by the industry.

The concerns included: the cost/performance relations derived from the

computer simulations were not consistent with the experience of the

industry; the assumptions and procedures were flawed; and the industry

expressed doubts over the Department's experience with selection of

appropriate design options.

In October, 1995, a moratorium on proposing, issuing, or

prescribing energy conservation standards took effect pertaining to

standards for central air conditioners and heat pumps, and the dialogue

between the air-conditioning industry and the Department, on the

analysis performed, was suspended.

2. Process Improvement

During consideration of the fiscal year 1996 appropriations, there

was considerable debate about the efficacy of the standards program.

The Department of the Interior and Related Agencies Appropriations Act

for Fiscal Year 1996 included the aforementioned moratorium on

proposing or issuing energy conservation appliance standards for the

remainder of Fiscal Year 1996. See Pub. L. 104-134. Congress advised

DOE to correct the standards-setting process and to bring together

stakeholders (such as manufacturers and environmentalists) for

assistance. In September 1995, the Department announced a formal effort

to consider further improvements to the process used to develop

appliance efficiency standards, calling on manufacturers, energy

efficiency groups, trade association, state agencies, utilities and

other interested parties to provide input to guide the Department. On

July 15, 1996, the Department published a Final Rule: Procedures for

Consideration of New or Revised Energy Conservation Standards for

Consumer Products (hereinafter referred to as the Process Rule). 61 FR

36974.

The Process Rule outlines the procedural improvements identified by

the interested parties. The process improvement effort included a

review of the: (1) Economic models, such as the Manufacturer Analysis

Model and Residential Energy Model; (2) analytical tools, such as the

use of a Monte Carlo sampling methodology; and (3)

[[Page 66308]]

prioritization of future rules. The Process Rule requires the

evaluation of uncertainty and variability by doing scenario or

probability analysis (as detailed in the Process Rule, 10 CFR part 430,

subpart C, appendix A sections 1(f), 4(d)(2), and 10(f)(1)). In

addition, an Advisory Committee on Appliance Energy Efficiency

Standards, consisting of a representative group of these interested

parties, was established to make recommendations to the Secretary

regarding the implementation of the Process Rule.

The Process Rule is applicable in this rulemaking to develop new

central air conditioner and heat pump standards. In this Supplemental

ANOPR, the Department is presenting the framework by which it will

develop the standards. The framework reflects improvements and steps

detailed in the Process Rule. The rulemaking process is dynamic. If

timely new data, models or tools that enhance the development of

standards become available, they will be incorporated into the

rulemaking. For example the Advisory Committee has made several

recommendations and the Department has developed new models which are

discussed in this Supplemental ANOPR.

The Department held a workshop on June 30, 1998 to discuss the

analytical framework that was being proposed for conducting the central

air conditioner and heat pump rulemaking. The analytical framework

presented at the workshop described the different analyses (e.g., the

LCC, payback and national impact analyses) to be conducted (See Table

1), the methods proposed for conducting them, and the relationship

among the various analyses.

Table 1.--Central Air Conditioner and Heat Pump Analyses Under Process Rule

----------------------------------------------------------------------------------------------------------------

ANOPR NOPR Final Rule

----------------------------------------------------------------------------------------------------------------

Screening Analysis................... Revised Pre-ANOPR Analyses Revise Analyses (LCC and National Impacts

(LCC and National Impacts Analyses).

Analyses).

Engineering Analysis................. Consumer Sub-group Analysis.

LCC Analysis......................... Industry Cash Flow Analysis

(GRIM).

Preliminary National Impacts Analysis Manufacturer Impact Analysis.

Utility Impact Analysis.

Environmental Analysis.

----------------------------------------------------------------------------------------------------------------

A number of concerns were raised at the framework workshop relating

to the application of the Process Rule to the central air conditioner

and heat pump rulemaking, with particular emphasis on (1) the

appropriate approaches for conducting the Engineering Analysis, (2) how

to validate manufacturer cost figures submitted by ARI, (3) methods for

developing consumer equipment price data, and (4) how non-regulatory

issues, e.g., the phase-out of hydro-fluoro-chloro-carbon (HCFC)

refrigerants might affect the effective date of any new standards.

In response to the concerns and comments of interested parties at

the Framework Workshop, the Department decided to perform the

Engineering Analysis based on the efficiency-level approach rather than

the design option approach, using cost data submitted by manufacturers

in aggregate via their trade association, ARI. The Department also

decided to utilize a reverse engineering approach as a ``stand alone''

analysis for developing manufacturer costs and validating the ARI-

provided manufacturer's cost data. Both approaches are discussed in

detail in the discussion of the Engineering Analysis (II C.).

As part of the information gathering and sharing process, the

Department and its contractors met several times with members of the

ARI Unitary Equipment Regulatory Committee, presenting the preliminary

manufacturer costs developed through the reverse engineering approach

and demonstrating the LCC spreadsheet model. During this time period,

ARI submitted relative production cost data for the four different

product classes of central air conditioners and heat pumps (split

system and single package for both air conditioners and heat pumps) for

3-ton capacity systems at various efficiency levels. Efficiency levels

are defined differently for air conditioners and for heat pumps. Air

conditioner efficiency is defined by the descriptor, Seasonal Energy

Efficiency Rating (SEER). Heat pump efficiency is defined by the

descriptor, Heating Season Performance Factor (HSPF) while operating

during the heating season and by SEER while operating during the

cooling season. The cooling season efficiencies provided by ARI ranged

from 11 to 14 SEER. The individual manufacturers provided their costs,

which were normalized to 10 SEER equipment costs, to ARI. ARI

aggregated the individual manufacturers' costs and provided the

Department with minimum, maximum and shipment-weighted mean values.

As will be discussed in the Engineering Analysis, the ARI-provided

and reverse engineering manufacturer costs overlap considerably,

especially at the lower efficiency levels in the split air conditioning

class and in the middle efficiency levels of the split heat pump class.

For the most part, the range between ARI's minimum and mean

manufacturer costs completely encompasses the reverse engineering

costs. This agreement is encouraging given the levels of uncertainty

and variability involved in estimating representative manufacturer

costs under different efficiency baselines across a diverse industry.

These areas of convergence provide an excellent indication of the most

likely costs of producing equipment utilizing today's technology under

new standard levels.

Although the two sets of manufacturer costs do overlap, they

disagree in some respects. In particular, there are significant

differences in the breadth of the manufacturer cost distributions at

each efficiency level. The Department assumes that vigorous competition

in the market for minimum-efficiency equipment will compel

manufacturers to meet new standards at similar incremental manufacturer

costs, and that the market cannot sustain as broad a range of costs as

ARI's results may imply. Furthermore, we cannot replicate ARI's maximum

manufacturer costs without altering our underlying assumptions beyond

what we currently consider justified.

The Department and ARI have worked diligently to identify possible

sources of those discrepancies. The Department sincerely appreciates

ARI's and its members' dedicated participation in the Engineering

Analysis. Their relative manufacturer costs provide a solid

[[Page 66309]]

foundation for further analysis, and their frequent review of and input

to our validation effort is a valuable addition to our understanding of

the production and design issues associated with meeting higher

standards. The Department will work with ARI to understand the

remaining differences between our two sets of manufacturer costs.

With regard to the LCC, payback, and preliminary national impact

analyses, three new spreadsheet tools were developed for this

rulemaking in an effort to meet the objectives of the Process Rule. The

first spreadsheet calculates LCC and payback. The second one calculates

impacts of standards at various levels on shipments. The third

calculates the NES and national net present values (NPV) at various

standard levels. These spreadsheets and the results of the preliminary

analysis were posted on the Department's web site on August 24, 1999.

The preliminary results posted on the web consisted of two sets of

data: one set based on the manufacturer costs submitted by ARI and the

other set based on manufacturer costs developed through reverse

engineering. The Department suggested that any errors in the web site

materials be immediately brought to our attention for correction, and

that any other comments be submitted during the 75 day period following

publication of this Supplemental ANOPR.

The Department has reviewed the recommendations made by the

Advisory Committee on Appliance Energy Efficiency Standards on April

21, 1998. (Advisory Committee, No. 96) These recommendations relate to

using the full range of consumer marginal energy rates (CMER) in the

LCC Analysis (replacing the use of national average energy prices),

defining a range of energy price futures for each fuel used in the

economic analyses and defining a range of primary energy conversion

factors and associated emission reductions, based on the generation

displaced by energy efficiency standards for each rulemaking. The

Department has incorporated the use of consumer marginal energy rates

and a range of future energy prices for the analysis that was conducted

for this Supplemental ANOPR. The Department plans to incorporate the

recommendations on energy conversion factors in future analyses for the

Notice of Proposed Rulemaking (NOPR).

Today's Supplemental ANOPR pertains to central air conditioners and

heat pumps and utilizes the framework described in Section II. Both

written and verbal comments from the June 30, 1998 Framework Workshop

are being addressed in this document. The commentor's name and

organization are shown in parentheses after each comment. Written

comments are further identified by a number assigned to each set of

written comments received during the commentary period. Verbal comments

are further identified by the page number in the workshop transcript.

Written comments and the Workshop transcript are viewable at the

Department's Freedom of Information Reading Room described previously.

3. Test Procedure

Section 7(b) of the Process Rule states that necessary

modifications to test procedures concerning efficiency standards will

be identified and proposed before issuance of an ANOPR. The residential

central air conditioner and heat pump test procedure is currently being

revised to improve its organization and ease of use, with a proposed

rule expected in November, 1999. This revision of the test procedure is

not expected to alter the measured efficiencies as determined under the

existing test procedure. Therefore, the revised test procedure would

not affect development of revised efficiency standards. For these

reasons, revisions to the test procedure are not a ``necessary

modification'' as that term is used in the Process Rule, but rather a

routine update, and hence need not be proposed before issuance of the

proposed rule for these standards.

II. Central Air Conditioner and Heat Pump Analyses

This section includes a general introduction to each analysis

section and provides a discussion of issues relevant to energy

conservation standards for central air conditioners and heat pumps.

The Department received a number of general comments from Energy

Market & Policy Analysis (EMPA) regarding the analysis conducted for

the rulemaking (EMPA, # 3). Some of these concern the rulemaking

procedure, while others refer to the analytic methods, and are as

follows: the methodology for evaluating standards is extremely complex

and increasingly unrealistic; approaches, models, assumptions, data,

and data sources need to be more detailed and should to be put out for

public comment before issuance of the ANOPR; and inadequate

consideration is given to the impact of standards on ``real consumers''

as EMPA believes that groups on the DOE Advisory Committee do not

represent and protect the interests of ``real consumers.''

The Department appreciates the concerns expressed previously. The

methods and approaches used for the analyses conducted for this

Supplemental ANOPR are well described and have been released on the

Department's web site prior to the issuance of this notice. Any

questions or comments as to how to clarify the methodologies used in

this rulemaking are always welcome and appreciated.

A. Preliminary Market and Technology Assessment

The preliminary market and technology assessment characterizes the

relevant product markets and existing technology options including

prototype designs.

1. Market Assessment

a. General

When initiating a standards rulemaking, the Department develops

information on the present and past industry structure and market

characteristics of the product(s) concerned. This activity consists of

both quantitative and qualitative efforts to assess the industry and

products based on publicly available information. Issues to be

addressed include: (1) Manufacturer market share and characteristics;

(2) trends in the number of firms; (3) the financial situation of

manufacturers; (4) existing non-regulatory efficiency improvement

initiatives; and (5) trends in product characteristics and retail

markets. The information collected serves as resource material to be

used throughout the rulemaking. For instance, historical product

shipments and prices are used to help predict future prices and

shipments. Market structure data are particularly useful in conducting

the competitive impacts analysis.

b. Product Specific

The Department reviewed existing literature and interviewed

manufacturers to get an overall picture of the residential central air-

conditioning market in the United States. Industry publications and

trade journals, government agencies, and trade organizations provided

the bulk of the information, including: (1) Manufacturer market share;

(2) shipments by capacity and efficiency level; (3) price distribution;

(4) market saturation; and (5) distribution trends. The information

described is discussed in the sections where it is used in the

analysis.

Edison Electric Institute (EEI) commented that contractors should

be interviewed when market assessments are being developed (EEI, # 2)

while the

[[Page 66310]]

Oregon Office of Energy (OOE) requested the Department to gather

information on trends in product characteristics and non-regulatory

efficiency improvement initiatives, and to interview manufacturers of

components (compressors, motor/fan assemblies, heat exchangers) on

initiatives to improve system efficiency. (OOE, # 7) The Department

relied predominantly upon literature searches and input from equipment

manufacturers while developing its market assessment, but also

interviewed national contracting organizations, independent contractors

and component suppliers. Of course, this market assessment is

preliminary, and any additional comments will be taken into

consideration when the assessment is revised.

2. Technology Assessment

a. General

Information relating to existing and past technology options and

prototype designs are typically used as inputs to determine what

technologies manufacturers utilize to attain higher energy efficiency

levels. In consultation with interested parties, the Department

develops a list of technologies that can and should be considered.

Initially, the technologies encompass all those considered to be

technologically feasible and serve to establish the maximum

technologically feasible design.

b. Product Specific

The Department based its list of technically feasible design

options on design options included in a previous ANOPR (58 FR 47326,

September 8, 1993). The Department then updated the list through

consultation with manufacturers of components and systems, trade

publications, and technical papers. Since many options for improving

product efficiency are available in existing equipment, product

literature and direct examination provided additional information.

Further descriptions of the most current technologies are provided in

the engineering section of the Preliminary TSD.

OOE asserted that all appropriate component and system technologies

must be considered in the technology assessment, and that it should

include microchannel heat exchangers and electrohydrodynamic

enhancement technologies (OOE, # 7). Additional technologies were

considered as set forth in the Technology Screening Analysis (section

II.B.3) including such emerging technologies as microchannel heat

exchangers, modulating compressors, and advanced variable speed motors

and controls. Electrohydrodynamic enhancement technologies were not

considered as they have yet to be publicly demonstrated in prototypical

central air conditioner and heat pump designs.

3. Preliminary Baseline Shipments Forecast

a. General

The Department develops a preliminary baseline forecast of product

shipments that assumes no new standards. This is an initial step in an

iterative process. Subsequently, a more comprehensive baseline

shipments forecast is prepared using a shipments model, superceding the

preliminary forecast.

The baseline shipments forecast is used as an input to the National

Benefits Analysis. To perform the National Benefits Analysis, a

forecast of shipment-weighted product efficiencies is prepared to the

year 2030. To assess the average impact on the affected consumer, a

forecast of product shipments by efficiency level was prepared for the

year a new standard would come into effect.

b. Product Specific

The Department prepared a baseline shipments forecast for central

air conditioners and heat pumps. Data on historical product shipments

guided preparation of the preliminary baseline shipments forecast.

The Oregon Office of Energy (OOE) pointed out that non-regulatory

energy efficiency programs are on the wane, and that if these programs

are to be considered in shipment forecasting, it must be quantifiably

demonstrated how they will transform the market (OOE, #7). Information

from parties involved in market-based initiatives for increasing the

sales of high-efficiency models was reviewed, but provided no

quantifiable measure of how these programs impact product efficiencies

on a national basis. However, because the baseline forecast assumes an

efficiency distribution of 10.7 SEER, based on current sales, the

impact of market-based initiatives is implicit in the baseline

forecast.

OOE also noted that since central air conditioning is not an

essential appliance for most areas of the country, central air

conditioning purchase price elasticities will likely be different than

those used for forecasting shipments in other product rulemakings (OOE,

#7). Since the shipments model used in this rulemaking was prepared

specifically for central air conditioners and heat pumps, the

Department believes this concern is addressed. The shipments model is

further described in the Preliminary National Impacts Analysis

discussion in section E.1.b.ii.

B. Screening Analysis

The Screening Analysis reviews various technologies with regard to

whether they: (a) Are technologically feasible; (b) are impracticable

to manufacture, install and service; (c) have an adverse impact on

product utility or product availability; and (d) have adverse impacts

on health and safety. The subsequent Engineering Analysis does not

consider or incorporate technologies that do not pass these tests,

regardless of whether the Engineering Analysis takes a Design Option

approach or an Efficiency-level approach. Technologies that pass the

Screening Analysis tests may be considered further to determine their

potential cost and efficiency impacts. The Screening Analysis also

identifies possible product classes and baseline equipment to serve as

a basis for further analysis.

1. Product Classes

a. General

Product types are divided into classes using the following

criteria: (a) The type of energy used; (b) capacity; and (c)

performance-related features that affect consumer utility or

efficiency. Different energy efficiency standards are applied to

different product classes. In general, classes are defined using

information obtained in discussions with appliance manufacturers, trade

associations, and other interested parties.

b. Product Specific

As prescribed by the National Appliance Energy Conservation Act

(NAECA), central air conditioners and heat pumps are each categorized

into split and single package systems, giving four product classes. The

analysis performed to date includes only products in these four product

classes at a nominal 3 ton capacity. However, there may be

justification for establishing additional classes including product

types such as:

Through-the-wall condensing units,

Ductless split systems,

High-velocity space-conditioning systems, and

Vertical packaged, wall mounted.

The Department is also considering establishing new classes defined

by the cooling or heating capacity of the equipment.

OOE felt that the addition of more classes may be reasonable. For

example, mini-splits and combined space/water

[[Page 66311]]

heating systems might be considered as separate classes based on their

characteristics and configuration constraints (OOE, #7).

EEI commented that the product classes be expanded to include gas-

fired air-conditioning equipment. Gas-fired equipment would then not be

included as a design option, but as an additional product class for

which baseline models must be developed. (EEI, # 2) Although the

Department appreciates EEI's comments, the NAECA definition of central

air conditioners subsumes only certain types of electric driven

systems. This rulemaking addresses only products covered by that

definition, and thus, no consideration will be given here to developing

standards for fuel driven technologies.

With regard to the additional product classes listed in this

section, the Department is seeking input on whether they need to be

established.

2. Baseline Equipment

a. General

The Department defines baseline equipment for each product class as

the starting point for analyzing energy efficiency improvements.

Baseline equipment are models with the minimum allowable energy

efficiency specified by the NAECA. Such baseline equipment are

typically ``low-end'' units that contain no premium features, e.g.,

noise reduction or appearance features.

b. Product Specific

Efficiency is the most important statistic required to establish

the baseline model. Current minimum efficiency standards for split and

single package system central air conditioners and central air

conditioning heat pumps are 10.0 and 9.7 SEER, respectively. The

current minima for the heating performance of split and single package

central air conditioning heat pump systems are 6.8 and 6.6 HSPF,

respectively. The Department used the split system minimum efficiency

standards as the baseline efficiency for each of the above classes. If

additional classes are created, the Department will apply the

appropriate existing standard as the baseline efficiency for that

class.

OOE agreed with the Department's intent to use the efficiency of

products that just meet the current minimum NAECA requirements as the

baseline efficiency. (OOE, #7)

3. Technology Screening

a. General

An initial list of efficiency enhancement options is developed from

the technologies identified in the technology assessment. Then the

Department, in consultation with interested parties, reviews the list

to determine if they are practicable to manufacture, install and

service, would adversely affect product utility or product

availability, or would have adverse impacts on health and safety.

Efficiency enhancement options not eliminated in the screening process

are considered further in the Engineering Analysis.

b. Product Specific

Compiling a list of efficiency enhancement options provided an

understanding of the technologies available to manufacturers to improve

equipment efficiency. This understanding also helped the Department

estimate maximum technologically feasible efficiency levels. For split

air conditioners, the Department believes, based on a preliminary

analysis, that 20 SEER is the highest efficiency level attainable by

2006 on a commercially practicable basis using design and technology

options that pass the screening criteria. These include the following:

enhanced and oversized heat transfer surfaces; variable or multispeed

or variable capacity compressors; high efficiency compressors;

electrically-commutated, variable-speed fan or blower motors, and

thermostatic or electronic expansion valves. We assumed that the

efficiency of compressors, motors, and heat transfer surfaces would

improve slightly prior to the effective date of any new rule. The 20

SEER level does not depend on any emerging technologies, because the

Department believes that, although those technologies could reduce the

cost of the equipment in the SEER 13 to SEER 17 range compared to

established technologies, the emerging technologies will not advance

the maximum attainable efficiency level.

The analysis of manufacturing costs and prices was based only on

technologies and designs available in mass produced products as of

1998. The Department considered the potential cost impact of emerging

technologies in a separate analysis described in the Preliminary TSD.

The emerging technologies that pass the screening criteria include:

Microchannel heat exchangers

Advanced compressors

Variable speed motor controls

The American Council for an Energy Efficient Economy (ACEEE), OOE,

Modine Manufacturing (Modine), and York International (York) all

provided comments pertaining to emerging technologies. Both ACEEE and

OOE suggested that all advanced or emerging technologies be considered

(ACEEE, #5; Steve Nadel, ACEEE, Transcript, pp 80-81; OOE, #7) . ACEEE

identified improved compressors and microchannel heat exchangers. ACEEE

also stated that emerging technologies could be analyzed in the context

of a reverse engineering analysis. Modine stated that PF (microchannel)

heat exchangers are a viable technology for improving equipment

efficiency, but their acceptance should be driven by market needs

rather than through a desire to push the technology into the market

(Modine, #1). Bristol Compressors (Bristol) is now bringing to market

the Twin-Single (TS) compressor, a reciprocating compressor that

reduces system capacity by de-activating one or more pistons under

part-load operating conditions. Bristol states that this technology can

increase central air conditioner and heat pump efficiency from either

10 to 12 SEER or from 12 to 14 SEER. With a variable-speed indoor

blower, the TS can increase system efficiency from 10 to 14 SEER (York,

#4).

In contrast, an industry representative contended that emerging

technologies would already be in the marketplace if they were feasible

and that, in the context of conducting an Engineering Analysis based on

the use of the efficiency-level approach, emerging technologies should

not be considered until they are shown to radically change the shape of

the industry cost curve. (Jim Crawford, The Trane Company (Trane),

Transcript, pp 81,87) ARI stated that in developing an aggregate

industry cost curve, emerging technologies may or may not be included

depending on whether manufacturers submitting data include them in

their cost estimates (Ted Leland, ARI, Transcript, pp 85).

The Department has performed a preliminary assessment of the

potential impact of these technologies on the manufacturing costs of

air-conditioning equipment and is seeking comment on the following:

Whether these emerging technologies do in fact pass the screening

criteria; the potential impact of these technologies on manufacturing

cost, operating cost, and price; whether additional emerging

technologies should be considered; and whether the maximum

technologically feasible level is commercially practical.

The Department notes that it is not considering fuel-driven

technologies, such as gas-fired engine driven heat pumps, absorption

heat pumps, and Stirling refrigeration cycles, as design options for

central air conditioners and heat pumps. NAECA defines a central air

conditioner and heat pump, in part,

[[Page 66312]]

as being ``powered by single phase electric current.'' This rulemaking

concerns only products that meet the NAECA definition. Thus, fuel-

driven technologies are precluded from consideration here.

C. Engineering Analysis

The purpose of the Engineering Analysis is to estimate the energy

savings potential from increased equipment efficiency levels and the

costs of achieving those levels, compared to the baseline equipment.

The increased efficiency levels are associated with increased

production costs. The efficiency/cost relations developed in the

Engineering Analysis are combined with end-user costs in the LCC

Analysis.

1. Energy Savings Potential and Production Costs

a. General

The Engineering Analysis estimates the energy savings potential of

the individual or combinations of design options not eliminated in the

previous Screening Analysis. The Department, in consultation with

stakeholders, uses the most appropriate means available to determine

energy consumption, including an overall system approach or engineering

modeling. Ranges and uncertainties in performance are established.

The Engineering Analysis involves adding individual or combinations

of design options to the baseline equipment. A cost-efficiency

relationship is developed to show the manufacturer cost of achieving

increased efficiency. The efficiency levels corresponding to various

design option combinations are determined from manufacturer data

submittals and from DOE engineering calculations.

EPCA requires that, any new or amended standard, ``shall be

designed to achieve the maximum improvement in energy efficiency that

the Secretary determines is technologically feasible and economically

justified.'' EPCA, section 325(l)(2)(A), 42 U.S.C. 6295(l)(2)(A). An

essential role of the Engineering Analysis consists of identifying the

maximum technologically feasible level. The maximum technologically

feasible level is one that can be reached by the addition of efficiency

improvements and/or design options, both commercially feasible or in

working prototypes, to the baseline equipment. The Department believes

that the design options must have been physically demonstrated in at

least a prototype form to be considered technologically feasible.

Three methodologies can be used to generate the manufacturing costs

needed for the Engineering Analysis. These methods include: (1) The

design-option approach, reporting the incremental costs of adding

specific design options to a baseline model; (2) the efficiency-level

approach, reporting relative costs of achieving energy efficiency

improvements; and/or (3) the reverse engineering or cost-assessment

approach which requires a ``bottoms-up'' manufacturing cost assessment

based on a detailed bill of materials for models that operate at

particular efficiency levels. The Department considers public comments

in determining the best approach for a rulemaking.

If the efficiency-level approach is used, the Department will

select appropriate efficiency levels for data collection on the basis

of: (1) Energy savings potential identified from engineering models;

(2) observation of existing products on the market; and/or (3)

information obtained for the technology assessment. Stakeholders will

be consulted on the efficiency-level selection.

The use of a design-option approach provides useful information

such as the identification of potential technological paths

manufacturers could use to achieve increased product energy efficiency.

It also allows the use of engineering models to simulate the energy

consumption of different design configurations under various user

profiles and applications. However, the Department recognizes that the

manufacturer cost information derived in the design-option approach

does not reflect the variability in design strategies and cost

structures that can exist among manufacturers. Therefore, the

Department may derive additional manufacturing cost estimates from

other approaches developed in consultation with interested parties.

The reverse engineering or cost-assessment approach can be used to

supplement the efficiency-level or design option approaches under

special circumstances when data is not publically available for

proprietary reasons, the product is a prototype and/or the data is not

provided by the manufacturers.

b. Product Specific

The Department, in consultation with stakeholders, has used both

overall efficiency level and reverse engineering approaches. The

efficiency-level analysis relies upon manufacturer cost submittals from

ARI while the reverse engineering analysis relies upon manufacturer

costs developed by Arthur D. Little, Inc. (ADL) for the Department. The

design options selected in the Screening Analysis helped to establish

potential efficiency improvements.

Manufacturing cost estimates under the efficiency-level approach

were submitted by individual manufacturers to ARI. For purposes of

ensuring manufacturer confidentiality, ARI submitted to the Department

minimum, maximum, and shipment-weighted averages of incremental

manufacturer cost increases associated with various efficiency levels.

In the case of the reverse engineering approach, ADL derived

manufacturing cost estimates from detailed incremental cost data

enabling them to establish costs for labor, purchased parts and

material, shipping/packaging, and investment. Both sets of manufacturer

costs were input into the Engineering Analysis and cost-efficiency

relationships were developed to show the manufacturing costs of

achieving various levels of increased efficiency.

As discussed earlier in the section on Process Improvement,

attempts were made to reconcile differences between the ARI and the

preliminary reverse engineering production cost data. Feedback from the

industry resulted in revising the reverse engineering production costs

of such components as outdoor cabinet (labor and materials), indoor

coil (materials) and refrigerant materials. Packaging and shipping

costs were also revised. The Department is continuing consultations

with manufacturer representatives regarding other industry suggested

issues, including manufacturing production volume, copper and aluminum

raw material costs, compressor costs, indoor and outdoor coil costs,

and freight costs. For more detail on how the ARI and the reverse

engineering costs were developed, and our revisions to the reverse

engineering costs, please refer to the Preliminary TSD. As noted

earlier, these revisions helped to reconcile some of the differences

between the ARI production costs and the reverse engineering production

costs, but remaining differences between the two sets of manufacturer

cost require further examination.

i. Efficiency-Level Approach

The efficiency-level approach establishes the relationship between

manufacturer cost and increased efficiency at predetermined efficiency

levels. It has the distinct advantage of being simple and straight

forward. Manufacturers typically provide incremental manufacturer cost

data for

[[Page 66313]]

incremental increases in efficiency. Cost-efficiency curves can be

easily constructed to clearly identify at what point manufacturers are

incurring significant costs to raise efficiency. Additionally, the

efficiency-level approach allows manufacturers the ability to supply

detailed cost data without revealing their unique design strategies for

achieving increased efficiency levels.

But the simplicity of the efficiency-level approach is also its

primary drawback. Namely, since technological details are not provided,

it is extremely difficult to verify whether the costs provided for each

specific efficiency level are truly representative of the costs for

that level. In addition, prototypical designs become difficult to

evaluate and maximum technologically feasible designs are then

difficult to ascertain. As a result, some other type of analysis is

likely needed in order to verify the accuracy of the costs supplied

through the efficiency-level approach.

In reply to the Department's request to stakeholders at the 1998

Framework Workshop regarding the most appropriate approach which should

be pursued for the Engineering Analysis, some industry members stated

their support for the efficiency-level approach (Ted Leland, ARI; David

Lewis, Lennox International Inc (Lennox), Transcript, pp 55-56, 61,

76). More specifically, these industry members stated their intention

to provide costs under the efficiency-level approach as one cost-

efficiency curve that would represent an aggregate of the entire

industry, i.e., a smooth curve relating the relative manufacturer cost

increases associated with increased efficiency. Industry indicated that

the curve would represent the 90th percentile, i.e., the cost

efficiency level at which 90% of manufacturers would be able to produce

product.

ACEEE and the OOE stated they would be willing to accept the

efficiency-level approach only if certain conditions were met (ACEEE,

#5, OOE, #7; Steven Nadel, ACEEE, Transcript, pp 65-67; Charlie

Stephens, OOE, Transcript, pp 65-67). For example, in addition to

providing costs at the 90th percentile, costs at multiple percentiles

should be reported. Having the full distribution of costs allows for a

more meaningful probability analysis to be conducted. With regard to

heat pumps, costs should be collected for achieving different HSPF

levels in addition to providing costs at different SEER levels. ACEEE

and OOE stated that verification of the costs submitted is extremely

important and they suggest that DOE staff members or consultants be

permitted to inspect raw data in order to ascertain its reasonableness.

OOE suggested that a reverse engineering or design option approach be

used to verify the cost data, although they prefer the design option

approach. ACEEE also contended that a design approach could be used to

verify cost data. ACEEE stated that it is more important to verify

costs submitted for high-efficiency equipment (14 to 15 SEER) as

current market prices do not reflect mature market costs. Both the

Consortium for Energy Efficiency and the Pacific Gas and Electric

Company (PG&E) supported ACEEE's conditions for adopting the

efficiency-level approach (CEE, #6; PG&E, #8). In addition, PG&E

believed that the cost of efficiency upgrades for heat pumps will be

similar to air conditioners since their components are nearly identical

(PG&E, #8).

On the issue of cost verification, one industry representative

contended that if industry provided disaggregated cost data it would

allow for the determination of the sources of the data and, thus,

result in violation of anti-trust laws. (Jim Crawford, Trane,

Transcript, pp 70-72) In any case, he stated that if the reverse

engineering approach were used and it validated the aggregated industry

cost-efficiency curve the issue of cost verification would be a moot

point.

The Department selected two approaches, one of which was the

efficiency-level approach, for conducting the Engineering Analysis.

Specific efficiency levels were selected by the Department based on

consultations with stakeholders. In the case of central air

conditioners, efficiency levels were based upon SEER. Efficiency levels

for heat pumps were based upon both the cooling season SEER and the

heating season HSPF efficiencies.

ARI collected data from individual manufacturers and, rather than

providing only costs at the 90th percentile, submitted minimum,

maximum, and shipment-weighted mean incremental manufacturer costs for

five distinct efficiency levels (11, 12, 13, 14, and 15 SEER). ARI also

provided incremental manufacturer costs for heat pumps for the same

five SEER levels. Since heat pumps are also rated for their heating

performance using the HSPF efficiency descriptor, the Department

developed a simple relationship between the two efficiency descriptors

for purposes of setting an HSPF standard in addition to an SEER

standard. The Department assumed the following set of heating seasonal

performance factors corresponding to the above five SEER levels: 7.1,

7.4, 7.7, 8.0, and 8.2 HSPF).

Tables 2 to 5 show the incremental manufacturer costs, also called

manufacturer cost multipliers, which ARI submitted for the four primary

product classes for systems with cooling capacities of approximately 3

tons (36,000 Btu/hr). The manufacturer cost multipliers are used

together with the baseline manufacturer cost (which will be presented

in Section II.C.2.b.) to determine the manufacturer costs for each

efficiency level. For example, the mean manufacturer cost multiplier

for an 11 SEER split system air conditioners from Table 2 is 1.16 and

the baseline manufacturer cost for a split system air conditioner is

$454. Thus, the mean manufacturer cost for an 11 SEER split system air

conditioner is the product of the baseline manufacturing cost ($454)

and the cost multiplier (1.16), or $527. While the manufacturer cost

multipliers in Tables 2 to 5 included low and high values as well as

mean values, because the probability distribution for the cost data at

a given standard level are unknown, only the mean values were

subsequently used in the LCC Analysis (section II.D).

Table 2.--Split System Air Conditioners--ARI Manufacturer Cost

Multipliers

------------------------------------------------------------------------

SEER Low Mean High

------------------------------------------------------------------------

10........................................... ....... 1.00 .......

11........................................... 1.03 1.16 1.30

12........................................... 1.09 1.36 1.55

13........................................... 1.30 1.63 1.90

14........................................... 1.60 2.03 3.00

15........................................... 1.81 2.40 3.50

------------------------------------------------------------------------

Table 3.--Split System Heat Pumps--ARI Manufacturer Cost Multipliers

------------------------------------------------------------------------

SEER/HSPF Low Mean High

------------------------------------------------------------------------

10/6.8.......................................... ...... 1.00 ......

11/7.1.......................................... 1.05 1.10 1.15

12/7.4.......................................... 1.11 1.24 1.35

13/7.7.......................................... 1.17 1.44 1.66

14/8.0.......................................... 1.30 1.64 1.88

15/8.2.......................................... 1.75 2.09 2.52

------------------------------------------------------------------------

Table 4.--Single Package Air Conditioners--ARI Manufacturer Cost

Multipliers

------------------------------------------------------------------------

SEER Low Mean High

------------------------------------------------------------------------

10........................................... ....... 1.00 .......

11........................................... 1.03 1.19 1.27

12........................................... 1.15 1.30 1.40

13........................................... 1.40 1.63 1.75

14........................................... 1.59 1.87 2.00

[[Page 66314]]

15........................................... 1.89 2.23 2.92

------------------------------------------------------------------------

Table 5.--Single Package Heat Pumps--ARI Manufacturer Cost Multipliers

------------------------------------------------------------------------

SEER/HSPF Low Mean High

------------------------------------------------------------------------

10/6.8.......................................... ...... 1.00 ......

11/7.1.......................................... 1.06 1.14 1.25

12/7.4.......................................... 1.06 1.28 1.50

13/7.7.......................................... 1.45 1.60 1.90

14/8.0.......................................... 1.65 1.75 2.30

15/8.2.......................................... 1.93 2.13 2.47

------------------------------------------------------------------------

In response to EEI's comment that the Engineering Analysis should

include the impact of any standard on the EER rating of the equipment

(EEI, #2), the Department plans on conducting a Utility Impact Analysis

for the Notice of Proposed Rulemaking (NOPR). The Utility Impact

Analysis will capture the peak power impacts of an increased SEER

standard, which EEI is alluding to in their comment regarding the EER.

ii. Reverse Engineering Analysis

As mentioned in the previous section, a reverse engineering

approach was conducted in parallel with the efficiency-level approach

to validate the ARI production cost data. The use of a component-based

technology-costing (reverse engineering) approach provides useful

information including the identification of potential technological

paths manufacturers could use to achieve increased product energy

efficiency. Under this type of analysis, actual equipment on the market

is physically analyzed, i.e., dismantled, component-by-component to

determine what technologies and designs manufacturers employ to

increase efficiency. Independent costing methods or manufacturer and

component supplier data are then used to estimate the costs of the

components. This approach has the distinct advantage of using ``real''

market equipment to establish the technologies which manufacturers use

as the basis for estimating the cost to reach higher efficiencies.

The primary disadvantage of reverse engineering is the time and

effort required to analyze ``real'' equipment. Several models from a

diverse range of manufacturers may have to be assessed in order to

ensure that an accurate representation of technological paths for

increasing efficiency are identified. In addition, since only equipment

in the market is analyzed, prototypical designs may not be captured by

the analysis, thus making it difficult to establish maximum

technologically feasible designs.

The industry contends that a reverse engineering approach could be

used to verify the cost data submitted through the efficiency-level

approach but DOE must first define the acceptable level of variability

between the costs that are developed through each approach. (Jim

Crawford, Trane; David Lewis, Lennox, pp 110-113) Industry also

maintained that there is wide variation in production costs between

manufacturers due to the levels of services that are provided with the

purchase of the equipment. OOE stated that reverse engineering could be

used to validate the efficiency approach (OOE, #7) while ACEEE stated

that reverse engineering has the benefit of analyzing advanced

technologies. (Steven Nadel, ACEEE, pp 80-81)

The Department carried out the reverse engineering approach to

validate the cost estimates provided by ARI from the efficiency-level

approach. The manufacturer costs of 71 equipment models at eight

efficiency levels were estimated. Three 3-ton models were torn down:

(1) A 10 SEER split system cooling-only condenser, (2) a 10 SEER

packaged heat pump, and (3) a 12 SEER split system heat pump condenser.

Manufacturer submissions, catalog data, and the ARI Product Attributes

Database provided design information on the other 68 models. For split

system air conditioners, cost estimates were developed for whole-number

efficiency levels ranging from 10 to 17 SEER. For split system heat

pumps, cost estimates were developed for whole-number efficiency levels

ranging from 10 to 16 SEER. The heating efficiencies corresponding to

each of the whole-number SEER levels were: 6.8 HSPF for 10 SEER, 7.1

HSPF for 11 SEER, 7.4 for 12, 7.7 for 13, 8.0 for 14, 8.2 for 15, and

8.4 for 16. A limited set of models were analyzed for single package

systems. For single package air conditioners cost estimates were

developed for 10, 12, and 13 SEER efficiency levels while for single

package heat pumps cost estimates were developed for 10 SEER/6.8 HSPF

and 12 SEER/7.4 HSPF efficiency levels.

Tables 6 to 9 show the manufacturer cost multipliers developed by

reverse engineering for the four primary product classes. Probability

distributions rather than single point-values were used in the LCC

analysis. The low and high values shown in the following represent the

10th and 90th percentiles, respectively, of the distributions.

Table 6.--Split System Air Conditioners--Reverse Engineering

Manufacturer Cost Multipliers

------------------------------------------------------------------------

SEER Low Average High

------------------------------------------------------------------------

10........................................... 0.96 1.00 1.05

11........................................... 1.08 1.13 1.18

12........................................... 1.20 1.25 1.31

13........................................... 1.35 1.42 1.48

14........................................... 1.65 1.73 1.81

15........................................... 1.87 1.95 2.04

16........................................... 1.98 2.07 2.17

17........................................... 2.13 2.23 2.33

------------------------------------------------------------------------

Table 7.--Split System Heat Pumps--Reverse Engineering Manufacturer Cost

Multipliers

------------------------------------------------------------------------

SEER/HSPF Low Average High

------------------------------------------------------------------------

10/6.8......................................... 0.96 1.00 1.05

11/7.1......................................... 0.97 1.01 1.06

12/7.4......................................... 1.05 1.10 1.15

13/7.7......................................... 1.29 1.35 1.41

14/8.0......................................... 1.57 1.65 1.72

15/8.2......................................... 1.79 1.87 1.96

16/8.4......................................... 1.92 2.01 2.10

------------------------------------------------------------------------

Table 8.--Single Package Air Conditioners--Reverse Engineering

Manufacturer Cost Multipliers

------------------------------------------------------------------------

SEER Low Average High

------------------------------------------------------------------------

10........................................... 0.96 1.00 1.05

11........................................... ....... ....... .......

12........................................... 1.08 1.14 1.19

13........................................... 1.33 1.40 1.46

------------------------------------------------------------------------

Table 9.--Single Package Heat Pumps--Reverse Engineering Manufacturer

Cost Multipliers

------------------------------------------------------------------------

SEER/HSPF Low Average High

------------------------------------------------------------------------

10/6.8......................................... 0.96 1.00 1.05

11/7.1......................................... ...... ....... ......

12/7.4......................................... 1.11 1.16 1.22

------------------------------------------------------------------------

iii. Design Option Approach

Industry representatives contended that the design option approach

can only be conducted by industry personnel with years of experience,

but the industry is not willing to provide this expertise because of

the expense involved. (Jim Crawford, Trane; David Lewis, Lennox; Ted

Leland, ARI, Transcript, pp105-106) The industry also stated that DOE

should not provide funds for others to carry out this

[[Page 66315]]

approach because they lack the necessary expertise.

In contrast, ACEEE and OOE believe that the design option approach

has merits (Steven Nadel, ACEEE, Transcript, p 108; OOE, #7). ACEEE

stated that it can be useful for evaluating new technologies, while OOE

believes it is the approach of choice for conducting the Engineering

Analysis, since the impact of any single technology on cost and

efficiency is explicitly stated.

The Department used only the efficiency level and reverse

engineering approaches to establish the manufacturer costs of achieving

increased efficiency levels for the following reasons: (1) Central air

conditioners and heat pumps are complex products; (2) a wide variety of

options exist to improve their efficiency; (3) these options interact

in complex ways; and (4) the industry strongly opposed use of the

design option approach and was willing to provide data for the

efficiency-level approach.

iv. Outside Regulatory Changes Affecting the Engineering Analysis

There sometimes occur regulatory changes outside of the EPCA

efficiency standards process that can affect the manufacture of a

product. In some cases, such changes affect the energy efficiency of a

product. The Department has attempted to identify all regulatory issues

outside the efficiency standards process that would influence the

Engineering Analysis.

The central air conditioning and heat pump industry faces the

impending phase-out of HCFC-22, the refrigerant used in almost all the

equipment currently being installed in the U.S. The phase-out of HCFC-

22 begins in the year 2010, and the industry has responded by

conducting in-depth analyses of various HCFC-22 alternatives. The most

notable effort to date has been the ARI's Alternative Refrigeration

Evaluation Program (AREP). Under AREP, several HCFC-22 alternatives

were identified, and their effects on equipment capacity, efficiency,

and longevity, and other variables were established.

Two primary candidates have emerged from the field of alternatives:

R-410A and R-407C. Although R-410A shows promise of being able to

significantly raise equipment efficiencies, its high volumetric

capacity requires systems to be redesigned to handle the significantly

higher discharge pressures. R-407C is a virtual drop-in replacement,

but results in an efficiency degradation of 5-10% relative to HCFC-22.

In response to the issue of alternative refrigerants for HCFC-22,

industry representatives stated that manufacturing costs that will be

submitted will attempt to factor in the impact of switching to R-410A.

(Ted Leland, ARI, Transcript, pp 287-288; Jim Crawford, Trane, p 288;

David Lewis, Lennox, p 290, p 297) In response to a schedule presented

at the 1998 Framework Workshop showing that a new minimum standard

would become effective in the year 2005, the industry representatives

stated that the effective date of any new efficiency standard should

coincide with the phase-out date of HCFC-22 (the year 2010) or be in

the 2006 to 2010 time frame. Additionally, they warned that efficiency

gains through the use of R-410A are not as great as first believed.

In response to industry's proposal to postpone the effective date

of the standard, both ACEEE and OOE stated that DOE should make new

standards effective in 2005. (ACEEE, #5; OOE, #7; Steven Nadel, ACEEE,

Transcript, p 298; PG&E, #8) In their view, any delay will compromise

U.S. commitments to reduce global warming gases. OOE offers two

approaches for completing the rulemaking on-schedule: (1) Base the

rulemaking analysis on replacement refrigerants or (2) base the

analysis on HCFC-22 and use a correction factor to adjust equipment

performance based on the use of alternative refrigerants. PG&E adds

that an effective date of 2005 will allow any new building standards

proposed by the California Energy Commission (CEC) to include the

beneficial impact of higher-efficiency air conditioners. PG&E states

that if standards are delayed to 2010, then over 500,000 new California

dwellings would be significantly less efficient.

The Department has determined that the phase-out date for HCFC-22

is far enough in the future that it will not affect a manufacturer's

ability to meet any new efficiency standards, whether using HCFC-22

before the phase-out, or using alternative refrigerants before and

after the phase-out. The Department does not plan to delay the

effective date of any new standards to coincide with the phase-out date

of HCFC-22. The Engineering Analysis has therefore been based on the

assumption that equipment will use HCFC-22. However, the Department

recognizes that equipment design changes to accommodate alternate

refrigerants may alter the manufacturing cost-efficiency relationship

developed for HCFC-22 equipment. The Department welcomes input

regarding the analysis of equipment designed for alternate

refrigerants.

Other non-regulatory issues of concern to the industry include the

need to make systems increasingly tighter to prevent refrigerant leaks

due to the use of HCFC-based refrigerants (David Lewis, Lennox,

Transcript, p 298), and international standardization of test

procedures. (Jim Crawford, Trane, Transcript, pp 298-299). The

Department has not explicitly addressed these concerns in its current

analysis but welcomes any comments as to how to address these issues in

the course of the rulemaking.

2. Manufacturing Costs

a. General

In addition to being inputs to the Engineering Analysis,

manufacturing costs are used as the means of determining retail prices,

and are needed for the manufacturer impact analysis.

b. Product Specific

Two sets of manufacturing costs were prepared. Using an efficiency-

level approach, ARI collected data from individual manufacturers and

submitted incremental manufacturing cost estimates. The Department also

conducted a reverse engineering analysis to determine manufacturing

costs. This analysis included an assessment of uncertainty and

variability among manufacturers.

Baseline manufacturer costs, i.e., the costs associated with

producing equipment with efficiencies of 10 SEER, were also developed

through the reverse engineering analysis. Table 10 shows the baseline

manufacturer costs developed for the four primary product classes for

systems with cooling capacities of approximately 3 tons (36,000 Btu/

hr). Note that for split system air conditioners, two costs were

developed; one for systems sold without indoor blowers and the another

for systems sold with indoor blowers. (A split system air conditioner

is usually sold without an indoor blower when the air conditioner's

indoor unit is installed in conjunction with a heating furnaces that is

equipped with a blower). The uncertainty and variability of the

baseline costs are noted in the manufacturer cost multipliers derived

in the reverse engineering analysis (Tables 6 to 9) in the rows

identified as 10 SEER/6.8 HSPF.

Table 10.--Baseline Manufacturer Costs

------------------------------------------------------------------------

Without With

Product Class blower blower

------------------------------------------------------------------------

Split System A/C.................................... $367 $454

[[Page 66316]]

Split System Heat Pump.............................. ........ 615

Single Package A/C.................................. ........ 534

Single Package Heat Pump............................ ........ 589

------------------------------------------------------------------------

i. Characterizing Uncertainty

Consistent with the Process Rule, DOE places a range around the

average manufacturing costs of achieving various efficiency levels. The

OOE concurs with DOE's plan for dealing with uncertainty and

variability in manufacturer cost estimates. (OOE, #7) The ranges of

costs are used to generate retail prices for the consumer LCC Analysis,

and are used in the Industry Cash Flow Analysis.

ARI collected data from manufacturers and developed a shipment-

weighted mean, along with minimum and maximum cost multipliers for each

efficiency level to account for variability and uncertainty. Since the

actual distribution of manufacturer costs were not provided to the

Department, only the shipment-weighted means were used in the

calculation of retail prices and, in turn, the LCCs.

In conducting the reverse engineering approach, the Department

developed a range of cost estimates for each efficiency level. For each

efficiency level in each product class, the range of cost estimates

were approximated by multiplying the mean value by a uniform

distribution (from 95% of the mean to 105% of the mean) and a normal

distribution (centered on the mean, with a standard deviation of 1.9%).

The resulting cost distributions were then used in the calculation of

retail prices and, in turn, the LCCs.

ii. Variability in Cost Among Manufacturers

The Department is committed to assessing the differential impacts

of standards on different manufacturers. The results are used as inputs

for the sub-group analysis of manufacturing impacts, which entails

calculating cash flows separately for each class of manufacturer.

In previous analyses for other appliances, manufacturing costs

submitted to DOE have demonstrated large variability. In line with the

Department's preference, ARI therefore collected cost data

disaggregated by manufacturer, although, as discussed earlier, ARI

provided to the Department only aggregated shipment-weighted

manufacturer costs. Under the efficiency-level approach, this same

disaggregated company-specific cost information developed for the

Engineering Analysis can be used to perform Government Regulatory

Impact Analysis for each manufacturer or manufacturer subgroup. These

aggregated data, however, were insufficient to generate distributions

of costs by manufacturer. Therefore, only mean values were used in the

subsequent LCC Analysis.

iii. Proprietary Design

The Department considers in its analysis all design options that

are commercially available or present in a working prototype, including

proprietary designs. OOE stated that designs meeting the stated

criteria of a proprietary design should be analyzed as a design option,

providing the example of the microchannel heat exchanger (OOE, #7).

Proprietary designs are considered in the Department's engineering and

economic analyses. The Department looked at the potential impact of

proprietary heat exchanger and compressor designs plus any proprietary

designs that were part of equipment which were analyzed in the course

of the reverse engineering analysis.

The Department considered the potential impact of proprietary

designs as part of its preliminary assessment of design options. Its

initial conclusion is that the inclusion of proprietary designs will

not materially affect the results of the Engineering Analysis because

equipment can achieve the same efficiencies competitively using non-

proprietary designs. The Department intends to continue examining this

issue during the Manufacturing Impact Analysis and welcomes input on

the appropriateness of considering proprietary designs.

D. Life-Cycle Cost (LCC) and Payback Analysis

In determining economic justification, EPCA directs the Department

to consider a number of different factors, including the economic

impact of potential standards on consumers. EPCA also establishes a

rebuttable presumption that a standard is economically justified if the

additional cost of purchasing a product, attributed to the standard, is

less than three times the value of the first year energy cost savings.

EPCA, section 325(o)(2)(B)(iii), 42 U.S.C. 6295 (o)(2)(B)(iii).

To address these provisions the Department calculates changes in

LCCs to the consumers that are likely to result from the proposed

standard, as well as two different simple payback periods, i.e.,

distribution of payback periods, and a payback period calculated for

purposes of the rebuttable presumption clause. The effects of standards

on individual consumers include changes in operating expenses (usually

lower) and changes in total installed cost (usually higher). The net

effect is analyzed by calculating the change in LCC as compared to the

base case. The base case manufacturing cost is determined in the

reverse engineering analysis. The LCC calculation considers installed

consumer cost (equipment purchase price plus installation cost),

operating expenses (energy, repair, and maintenance costs), appliance

lifetime, and discount rate. The LCC Analysis is performed from the

perspective of the consumer.

At the ANOPR stage, the Department generates LCC and payback period

results as probability distributions using a simulation based on Monte-

Carlo methods, in which inputs to the analysis consist of probability

distributions rather than single-point values. As a result, the Monte

Carlo analysis produces a range of LCC and payback period results

rather than single-point values. A distinct advantage of this type of

approach is that the percentage of consumers achieving LCC savings or

attaining certain payback values due to an increased efficiency

standard can be identified in addition to the average LCC savings or

average payback for that standard. Because the analysis is being

conducted in this manner, the uncertainties associated with the various

input variables (as described in the next paragraph) can be expressed

as probability distributions. During the post-ANOPR consumer analysis,

the Department will evaluate additional parameters, and prepare a

comprehensive assessment of the impacts on sub-groups of consumers.

The LCC and one of the payback periods (distribution of payback

periods) are calculated using the LCC spreadsheet model developed in

Microsoft Excel for Windows 95, combined with Crystal Ball (a

commercially available software program), based on probability

distributions of input variables. The second payback, the Rebuttable

payback based on DOE test procedure assumptions for estimating annual

energy consumption, is not calculated using Crystal Ball and input

probability distributions, but is instead based on the spreadsheet

option allowing single-values for the input variables.

[[Page 66317]]

Based on the results of the Engineering and LCC Analyses, DOE

selects candidate standard levels for a more detailed analysis. The

range of candidate standard levels typically includes: (1) The most

energy-efficient combination of design options or most energy-efficient

level; (2) the efficiency level with the lowest LCC; and (3) an

efficiency level with a payback period of not more than three years.

Additionally, candidate standard levels that incorporate noteworthy

technologies or fill in large gaps between efficiency levels of other

candidate standards levels may be selected.

The payback, for purposes of the rebuttable presumption test,

attempts to capture the payback to consumers affected if a new standard

is promulgated. It compares the purchase cost and energy use of central

air conditioners and heat pumps consumers would buy in the year the

standard becomes effective with what they would buy without a new

efficiency standard. In some cases, this means comparing the baseline

energy efficiency and cost with those associated with the standard

level. In other cases, the standard level would also be compared to a

higher-efficiency appliance purchased without new standards (but at a

lower efficiency than the trial standard level). A weighted average of

these payback periods, in the year a new standard level would take

effect, is considered the payback for purposes of the rebuttable

presumption clause.

In addressing the usefulness of the LCC Analysis, an industry

representative asserted that LCCs have no relationship to market

dynamics, have no relationship to what the customer will buy, and have

no relationship to the cost effectiveness of any efficiency standard.

(Jim Crawford, Trane, Transcript, pp 135) But section

325(l)(2)(B)(I)(II) of EPCA requires the Department to consider the

savings and costs of standards, and virtually mandates performance of

an LCC Analysis.

One commenter during the Framework Workshop stated that tax credits

[incentives] for consumer purchases of high efficiency equipment should

be included in the LCC Analysis. (Transcript, pp 243) The Department

has not considered tax incentives in the LCC Analysis being presented

here, because there are no such tax benefits available under Federal

law. However, the Department seeks specific information from

stakeholders regarding whether the Department should consider LCC

analyses with alternative tax incentive scenarios.

1. LCC Spreadsheet Model

a. General

This section describes the LCC spreadsheet model used for analyzing

the economic impacts of possible standards on individual consumers. The

LCC spreadsheet model is available on the Department's web site for use

by interested parties who wish to modify the assumptions in the models

and view the results of those changes. The LCC Analysis is conducted

using a spreadsheet model developed in Microsoft Excel for Windows 95,

combined with Crystal Ball. The Model uses a Monte Carlo simulation to

perform the analysis considering uncertainty and variability. The

spreadsheet is organized so that ranges (distributions) can be entered

for each input variable needed to perform the calculations.

The Department wishes to consider the impacts of varying regional

climate, energy prices, and consumer behavior on LCCs and payback

periods. Calculations were therefore based on a Monte Carlo uncertainty

analysis in which variables are represented by probability

distributions of values. With this approach, the Department could

express LCCs and payback periods as national means, with ranges that

fully account for regional variations in climate, electricity cost, and

behavior. The spreadsheet has the capability to sample subsets of

households for the analysis of particular sub-populations, e.g., low

income households, and will be used for Consumer Sub-Group Impact

Analysis prior to issuance of the NOPR.

An industry representative commented that an LCC Analysis based

upon uncertain or distributional inputs is suspect and totally

unverifiable if the uncertainty of the inputs cannot be clearly

defined. (Jim Crawford, Trane, Transcript, pp 252-254) He suggested

that a simpler approach be used. Others supported the use of a

distributional LCC Analysis, commenting that this approach is better

than what has been used in prior rulemakings. (Charles Stephens, OOE;

Michael Martin, CEC, Transcript, pp 256) EEI stated that the use of

ranges of values for appliance price and life, fuel costs, energy

usage, and discount rates follows recommendations provided by the

Appliance Standards Advisory Committee. (EEI, #2) OOE asserts that use

of a distributional analysis creates potential pitfalls in accounting

for regional climatic and energy price variations. Use of traditional

methods for screening out design options based upon increased LCC or

excessively long payback periods will be more difficult as results for

one region may demonstrate that a design option is economically

attractive while another region does not. DOE must establish some basis

for rejecting or retaining design improvements. (OOE, #7) Although the

use of distributional LCC Analysis may be more complex, the Department

has decided it is the best approach to use to capture the uncertainty

and variability inherent in input variables. In response to OOE's

concerns for selecting appropriate standard levels, the Department will

keep in mind their concerns when selecting appropriate standard levels

for the NOPR.

In order to generate the distributions required for the analysis,

the Department used the Energy Information Administration's (EIA's)

Residential Energy Consumption Survey (RECS). The 1993 RECS is based on

a representative sample of 7,111 households from the population of all

primary, occupied residential housing units in the United States. Each

household is weighted so that the data properly represent the 96.6

million households in the 50 states and the District of Columbia

reported in the 1993 RECS.

RECS estimates end-use energy consumption and reports the age of

equipment as well as household energy prices. Of the over 7,000

households surveyed in RECS, 2550 households representing 35.6% of the

housing population have a central air conditioner while 651 households

representing 8.3% of housing population have an electric heat pump. The

distribution of LCC and payback results are generated by performing an

LCC and payback calculation for each RECS household with a central air

conditioner or heat pump. For example, in conducting the LCC Analysis

for a 12 SEER standard level for central air conditioners, all RECS

households with a central air conditioner have their existing equipment

``replaced'' first with a baseline (i.e.,10 SEER) system. The

corresponding LCCs of the baseline systems are then calculated. Then

all RECS households with a central air conditioner have their existing

equipment ``replaced'' with a 12 SEER system and the LCC of these

systems are established. On a household-by-household basis, the payback

periods and the LCC differences of the 12 SEER system are determined

relative to the economics of the baseline system. The result is a

distribution of LCCs and payback periods. Since climatic conditions and

consumer behavior affect the energy consumption of a given

[[Page 66318]]

piece of equipment, these data implicitly account for regional

variations. Similarly, variations in the RECS energy price data

represent the range faced by consumers in the U.S.

Both EEI and EMPA warned of problems using the RECS data in a LCC

and Payback Analysis. (EEI, #2; EMPA, #3) EEI asserts the following:

(1) The age of the RECS data (1993) is too old to be used with

efficiency and price data from 1998, (2) only total annualized average

electricity and fuel rates rather than summer marginal rates are

provided, (3) the stated age of the equipment may be inaccurate if the

households surveyed are not original homeowners, and (4) there is no

accounting of equipment used in small commercial facilities. EEI also

claims that RECS may not reflect regional or national equipment

saturations as the 1993 RECS shows that 42% of survey homes have a

central air conditioner while an industry publication (ACHR News, June

22, 1998) shows saturations ranging from 55% in the western U.S. to 99%

in the southern U.S. EMPA questioned whether the 7,000 to 8,000

households surveyed households in RECS can be representative of the 90

million households in the U.S. They also commented that RECS experts

from EIA needed to provide a written statement in support of the way in

which DOE plans to use the RECS data in its LCC analyses. In contrast

to these comments, OOE states that they are very comfortable with the

analysis methodology as it was applied to other products (clothes

washers) where RECS data was used to determine annual energy use and

equipment age. (OOE, #7)

Although the Department understands the concerns of the EEI and

EMPA, the 1993 RECS data is the most recent and appropriate database

available for conducting the desired distributional LCC Analysis. DOE

plans to conduct updates to the LCC and Payback Period Analysis with

the 1997 RECS. Use of this data will address most of the concerns

brought up by both EEI and EMPA.

Estimates of the efficiency of equipment currently in use are based

upon the age of the equipment as established by RECS and historical

shipment-weighted efficiency values. The age of the equipment

establishes the year of manufacture which in turn, using the shipment-

weighted efficiency data, allows for the determination of the

equipment's most probable efficiency. Replacing existing equipment with

new equipment results in reductions in energy consumption. These

reductions were approximated by multiplying current energy use by the

ratio of the efficiencies of existing and new equipment. Using an

energy price allowed for the calculation of the operating costs of

existing and new replacement equipment, and, in turn, the LCCs and

payback periods associated with different efficiency levels of new

equipment.

The Department developed LCCs and payback periods based on both

sets of manufacturer cost estimates developed in the Engineering

Analysis: (1) The ARI cost data developed through the efficiency-level

approach, and (2) the cost data developed through the reverse

engineering analysis.

A more detailed description of the methodology and contents of the

RECS database is contained in the Preliminary TSD.

b. Product Specific

This section discusses the approaches for analyzing the economic

impacts on individual consumers from potential new central air

conditioner and heat pump standards. An LCC spreadsheet model,

described previously in Section II.D.1.a, is used to calculate two of

the economic impacts, LCC and payback period, based on input variables

that have uncertainty and variability expressed with probability

distributions. A third economic impact, Rebuttable Payback Period, is

determined without the use of the spreadsheet model. In future

analyses, all three of these economic metrics will be compared to

baseline efficiencies of appliances sold in the year the new standard

would take effect. In this preliminary analysis, only the Rebuttable

Payback Period is compared to a distribution of efficiencies forecasted

to the year 2006.

i. LCC Analysis

The Department determined values of input variables for central air

conditioners and heat pumps, including total installed cost (consisting

of both the equipment purchase price and installation price), annual

energy use, lifetime, repair costs, and maintenance costs of equipment,

as well as average energy prices, marginal energy prices, and discount

rate. Table 11 summarizes some of the major assumptions used to

calculate the consumer economic impacts of various energy-efficiency

levels.

Table 11.--Assumptions Used in the LCC Analysis

----------------------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------------------------------

Total Installed Cost: Equipment Purchase Price......... Manufacturer cost multiplied by manufacturer markup,

distributor markup, dealer markup, and sales tax.

Installation Price................................. Central air conditioners--$1190; heat pumps--$2035.

Existing Equipment Efficiency.......................... Distribution imputed from RECS database based on

equipment age and historical shipment-weighted

efficiencies (central air conditioners--5.3 to 15.2

SEER, weighted average of 8.58 SEER; heat pumps--5.3

to 15.2 SEER, weighted average of 8.72 SEER; 4.88 to

9.67 HSPF, weighted average of 6.52 HSPF).

Existing Annual Energy Use............................. Distribution from RECS database (central air

conditioners--174 to 12,929 kWh/yr, weighted average

of 2629 kWh/yr; heat pumps--space-cooling equals 0 to

14,771 kWh/yr, weighted average of 2987 kWh/yr; space-

heating equals 162 to 29,839 kWh/yr, weighted average

of 4658 kWh/yr).

Average Energy Prices.................................. Historical--distribution from RECS database (central

air conditioners--2.70 to 16.50 cents/kWh, weighted

average 8.49 cents/kWh; heat pumps--2.60 to 13.00

cents/kWh, weighted average 7.86 cents/kWh);

projections--AEO--1999.

Marginal Energy Prices................................. Historical--estimated from RECS database (central air

conditioners--0.58 to 19.42 cents/kWh, weighted

average 8.74 cents/kWh; heat pumps--0.82 to 18.62

cents/kWh, weighted average 7.99 cents/kWh);

projections--scaled to trends in average energy

prices.

Lifetime............................................... Distribution based on empirical data (mean life is 18.4

years).

Discount Rate.......................................... Distribution (0% to 19%, weighted average 6.51%)

Repair Costs........................................... For systems with efficiencies of 10 SEER or greater

than 12 SEER, one-half equipment price divided by mean

lifetime. For systems with efficiencies of 11 or 12

SEER, 1% greater than the 10 SEER repair cost.

Maintenance Costs...................................... Distribution ($0 to $135/year, weighted average $36/

year).

----------------------------------------------------------------------------------------------------------------

[[Page 66319]]

Total Installed Cost: The total installed cost consists of the

equipment purchase price and the installation price. Markups are used

to convert the manufacturer cost to the equipment purchase price. The

determination of equipment purchase prices is described in the next

section.

Installation Price: The installation price represents all costs

required to install the equipment other than the marked-up equipment

cost. The installation price includes labor, overhead, and any

miscellaneous materials and parts such as linesets. For central air

conditioners the installation price used in the analysis used is $1190,

and for heat pumps it is $2035. The installation price was determined

by subtracting the derived equipment purchase price from the typical

total installed cost. The typical total installed cost values were

collected from public sources and phone calls to heating ventilating

and air conditioning (HVAC) contractors. While the data collected were

for split systems, the Department has assumed the installation prices

apply to single package systems, although installation price for these

systems might be somewhat lower than for the split systems, since only

single packages are involved and no line sets are required. The

Department is interested in obtaining information on the installation

prices for all classes of products.

Annual Energy Use: Currently, the DOE test procedure calculates

annual cooling and heating energy consumption based on 1,000 and 2,080

hours of operation, respectively. Although this procedure seems to be

widely accepted for comparing the seasonal performance of different

units, the procedure overstates equipment energy use compared to RECS

estimates. As described above, basing operating and LCC on RECS

household data provides a more accurate measure of the savings possible

from more-efficient equipment, and accounts for variability in LCCs due

to climatic conditions and energy prices.

Variations in energy use for a particular appliance can depend on

factors such as climate, type of household, people in household, etc.

For purposes of this analysis, annual energy use was based on the

annual end-use energy consumption values in RECS. Climatic and consumer

behavior are inherent to the RECS energy use data. The Department will

perform sensitivity analyses prior to issuance of the NOPR to consider

how differences in energy use will affect sub-groups of consumers.

For the RECS households with central air conditioners, the range of

annual space-cooling energy consumption is 174 to 12,929 kWh/year with

a weighted-average value of 2629 kWh/year. For the RECS households with

heat pumps, the range of annual space-cooling energy consumption is 0

to 14,771 kWh/year with a weighted-average value of 2987 kWh/year. The

annual space-heating energy consumption for households with heat pumps

ranges from 162 to 29,839 kWh/year with a weighted-average value of

4658 kWh/year.

For each RECS household equipped with either a central air

conditioner or heat pump, the annual energy use associated with a

particular standard level is calculated by taking the annual energy use

associated with the existing system and multiplying it by the ratio of

the existing system's efficiency to the efficiency of the standard

level of interest. To illustrate this approach, this calculation

procedure is carried out here based on the weighted-average annual

energy use and the weighted-average efficiency from all RECS households

equipped with central air conditioners. As presented earlier, for all

RECS households with a central air conditioner, the weighted-average

annual energy use and the weighted-average efficiency are 2629 kWh/year

and 8.58 SEER, respectively. Thus, for the case of a 12 SEER air

conditioner, the weighted-average annual energy use is determined

according to the following expression:

Weighted-average annual energy use of 12 SEER A/C = 2629 kWh/yr 4 x

(8.58 SEER 12 SEER) = 1880 kWh/yr

Of course, as the efficiency of the standard level being analyzed

increases, its corresponding annual energy use decreases

proportionally. It should be noted that in the case of establishing the

annual space-heating energy use of heat pumps, the ratio of HSPF values

are used rather than the SEER values. It must also be emphasized that

the above calculation is illustrative only. In order to generate the

distribution of LCC and payback results for a particular standard

level, each RECS household that is equipped with a central air

conditioner or heat pump is analyzed.

Concerning use of RECS data in the economic analysis, EEI stated

that, although energy use is dependent on equipment design, weather,

and consumer operation, it is also a strong function of house design,

landscape, and thermostatic controls, and their impacts should be taken

into consideration. (EEI, #2) They also stated that EER ratings, in

addition to SEER ratings, ranges of cooling capacity, and the climatic

impact on hours of operation, should also have an impact on energy use

and should also be considered. With regard to the annual operating

hours, EEI stated that a range of values based upon end-use metering

studies, load management programs, and other utility or research

organization studies should be used. They cited state utility

commissions, Internet web sites, and software providers as possible

sources for determining variations on energy use.

As stated earlier, the Department believes that the 1993 RECS is

the most recent and appropriate data available. In addition to the

equipment design, weather, and consumer operation, the RECS annual end-

use estimates also consider the household's shell characteristics

including any prominent shading. Past RECS data sets have been

validated against end-use metering studies in an attempt to better its

procedures for estimating end-use energy consumption. Although the

Department is comfortable with the use of RECS as its source for

establishing annual energy consumption, interested parties are welcome

to present any metered end-use data that could verify or substitute for

the RECS estimates.

Average Energy Prices: As discussed above, the Department is using

RECS household data to establish energy prices. Projections of future

energy prices for the LCC Analysis use high, low, and reference case

projections of national average electricity prices to residential

customers. The current edition of EIA's Annual Energy Outlook (AEO) is

used as the source of projections for uncertainty in the LCC analysis.

For the RECS households with central air conditioners, the range of

average electricity prices in 1993$ is 2.70 to 16.50 cents/kWh with a

weighted-average value of 8.49 cents/kWh. For the RECS households with

heat pumps, the range of average electricity prices is 2.60 to 13.00

cents/kWh with a weighted-average value of 7.86 cents/kWh. While

average energy prices establish the annual electricity cost of baseline

equipment (i.e., split-system air conditioners with efficiencies of 10

SEER and heat pumps with efficiencies of 10 SEER and 6.8 HSPF),

marginal energy prices establish savings in electricity costs

associated with increased efficiency standards.

Both EEI and EMPA stated that the average energy prices in RECS are

outdated and that marginal energy prices should be used in their place

in conducting the LCC and Payback Analysis. (EEE, #2; EMPA, #3) Both

[[Page 66320]]

pointed to subtracting out the fixed cost portion of the price as an

interim step in developing marginal prices. EEI suggested several data

sources for developing marginal prices including state utility

commissions, Internet web sites such as the PowerRates site, and

software providers such as such as EPS solutions and Energy

Interactive. EMPA stated that any work to identify marginal energy

costs should include a detailed description of the methodology and that

any data collection efforts must comply with Paperwork Reduction Act.

ACEEE noted how air conditioners are used during peak periods when the

cost of supplying electricity is high and that price data should be

collected during these periods for use in the economic analyses.

(ACEEE, #5)

Regarding future energy prices, several participants at the 1998

Framework Workshop stated that future residential electricity prices

will be dependent on the how the electric utility industry is

restructured. (Transcript, pp 220-230) EMPA was critical of EIA's

forecasts of future energy prices, stating that the forecasts have

consistently underestimated rates, and that EIA's forecasting models do

not reflect the factors resulting from the deregulation of the electric

utility industry. (EMPA, #3)

The Department used the most recent forecasts from the 1999 AEO to

predict the trend in both average and marginal electricity prices by

multiplying the average and marginal price for the base year (1998) by

the AEO's forecasted relative electricity price increases and/or

decreases. In addition, LCC and payback spreadsheets can be run with

price forecasts from the Gas Research Institute (GRI). The Department

believes these forecasts are the most reliable available to predict

future energy trends.

Marginal Energy Prices: Marginal energy prices are those prices

consumers pay for the last units of energy used. Marginal prices

reflect a change in a consumer's bill associated with a change in

energy consumed, consequently, marginal energy prices, rather than

average energy prices, are appropriate for determining energy cost

savings associated with increased efficiency standards. For LCC

analyses, the Advisory Committee recommended that DOE use the full

range of consumer marginal energy prices instead of national average

energy prices. Absent consumer marginal energy price information, the

Committee recommended DOE use a range of net energy prices, calculated

by removing all fixed charges. The Department agrees the use of

marginal energy prices improves the accuracy of the LCC Analysis and

has estimated marginal prices for electricity and natural gas.

The Department estimated consumer marginal electricity and natural

gas prices directly from household data in the 1993 RECS survey by

calculating the slopes of the regression lines of customers' bills vs.

energy consumption for these two fuels. Those slopes are equal to the

change in bill divided by the change in energy consumption, that is,

the marginal prices paid by each household. Since this rulemaking

concerns only energy efficiency standards that apply to electrically-

driven central air conditioners and heat pumps, only marginal

electricity prices are of concern here.

For electricity, the Department calculated separately the slopes of

the regression lines for four summer months (June-September) and for

the remaining (``winter'') months. The annual marginal price was

derived by taking the weighted average of the two seasonal prices,

where the weighting was the relative energy consumption of the

appliance in each season. For air conditioners/heat pumps, the

weighting was based on the regional location and age of each of the

households in the RECS sample.

Given restructuring of parts of the energy supply sector, customers

may have more than one bill (e.g., one from the distribution company,

and one or more from generators or suppliers). To capture complete

information, future surveys would best gather energy pricing

information directly from customers, rather than from utilities or

local distribution companies. Efficient collection of energy pricing

information in the future will require changing the current processing

of the billing information so as to gather consumption by month and

pricing information for each customer from the bills. The pricing

information would comprise the applicable rate schedule, including

marginal prices, fixed charges, and demand charges for commercial and

industrial customers, or time-of-use rates where applicable. The Office

of Energy Efficiency and Renewable Energy has expressed the need for

these data in discussions with EIA concerning the design of future

surveys.

Until a time series of marginal prices is available, the Department

will use projected trends in energy prices to derive estimates of

consumer marginal energy prices for the economic analysis of proposed

standards. An index (scaling factor) was created relative to current

prices from the trend in average prices (by fuel and sector) and was

applied to the current range of marginal prices. For example, if the

trend in average residential electricity prices was a decline by 20

percent over a given period of time, then we assume the marginal price

for each household would decline from its initial observed value by 20

percent over that same period.

The Department recognizes that a simple scaling of marginal energy

prices may be incorrect in a restructured electric power market.

Therefore, the Department may develop a different approach to forecast

future marginal energy prices when restructuring becomes more widely

implemented.

Given the uncertainty of projections, the Department has made

available to stakeholders the ability to conduct a scenario analysis to

examine the robustness of different efficiency levels under different

energy-price conditions. Each scenario provides a self-consistent

projection, integrating energy supply and demand. The scenarios differ

from each other in the energy prices that result. The Advisory

Committee suggested the use of three scenarios. While many scenarios

can be envisioned, the three scenarios specified are sufficient to

bound the range of energy prices.

The three scenarios suggested by the Advisory Committee are based

on projections in the 1999 AEO. The Department's most recent reference

case, published in the 1999 AEO, provides a well-defined middle

scenario. In addition, DOE can use the scenarios with the highest and

lowest energy prices in the sector from the range of scenarios in the

1999 AEO. The future trend in energy prices assumed in each of the

three scenarios is clearly labeled and accessible in each spreadsheet.

Also included as a scenario is the GRI energy price forecast for 1998.

Stakeholders can easily substitute alternative assumptions in the

Department's web site LCC spreadsheets to examine additional scenarios.

For the RECS households with central air conditioners, the range of

marginal electricity prices in 1993 dollars is 0.58 to 19.42 cents/kWh

with a weighted-average value of 8.74 cents/kWh. For the RECS

households with heat pumps, the range of marginal electricity prices is

0.82 to 18.62 cents/kWh with a weighted-average value of 7.99 cents/

kWh.

As discussed previously under the section describing average energy

prices, marginal energy prices are used to determine the annual

electricity costs associated with energy savings resulting from an

increased efficiency standard (i.e., any efficiency above baseline

efficiencies).

Lifetime: In choosing a value for lifetimes of central air

conditioners and

[[Page 66321]]

heat pumps, a variety of sources were reviewed. These studies on

lifetimes of central air conditioners and heat pumps indicates that

there is a wide range of values for lifetimes. The references are

provided in Table 12, with the mean lifetimes given in years.

Table 12.--Central Air Conditioner and Heat Pump Mean Lifetimes

------------------------------------------------------------------------

In years--

Source ---------------------------

Central AC Heat pump

------------------------------------------------------------------------

Appliance Magazine. The Life Expectancy/ 13.0 14

Replacement Picture, Sept. 1998 a..........

National Association of Home Builders. 15.0 15

Housing Facts, Figures, and Trends, 1998 b.

1995 ASHRAE Applications Handbook c......... 15.0 15

M.E. Bucher et al, American Electric Power ............ d 19

Service Corp. 1990. ``Heat Pump Life and

Compressor Longevity in Diverse Climates'',

ASHRAE Transactions 96(1):1567-1571........

K.A. Pientka, Commonwealth Edison Co. 1987. ............ d 15-16

``Heat Pump Service Life and Compressor

Longevity in a Northern Climate'', ASHRAE

Transactions 93(1):1087-1101...............

C.C. Hiller, EPRI and N.C. Lovvorn, Alabama ............ d 20

Power Co. 1987. ``Heat Pump Compressor Life

in Alabama'', ASHRAE Transactions

93(1):1102-1110............................

J.E. Lewis, Easton Consultants. 1987. 12.1 10.9

``Survey of Residential Air-to-Air Heat

Pump Service Life and Maintenance Issues'',

ASHRAE Transactions 93(1):1111-1127........

MTSC, Inc. Energy Capital in the U.S. 12.0 12

Economy, prepared for the Office of Policy,

Planning, and Evaluation, U.S. Department

of Energy, Nov. 1980 e.....................

------------------------------------------------------------------------

a Based on first-owner use. Central AC min life = 8, max life = 18. Heat

Pump min life = 10, max life = 17.

b Sources: Air Conditioning and Refrigeration Institute; Air

Conditioning, Heating, and Refrigeration News; Air Movement and

Control Association; American Gas Association; American Society of Gas

Engineers; ASHRAE.

c Source for Central A/C: Akalin, M.T. 1978. ``Equipment life and

maintenance cost survey'', ASHRAE Transactions 84(2):94-106. Source

for Heat Pump: ASHRAE Technical Committee 1.8, 1986.

d Median lifetime.

e Based on retirement function.

The available sources report mean and median lifetimes ranging from

10.9 to 20 years. The Department's analysis assumed a mean lifetime of

18.4 years, based on a 1990 ASHRAE technical paper that has the most

recent and most detailed information on heat pump life available, based

on a survey of 2,184 heat pump installations in a seven-state region of

the United States. The sources that report shorter average lifetimes

are based on data of a lesser quality, and the Department considers

those figures are less reliable. For example, in the case of Appliance

Magazine, the reported lifetime values are based on expert opinion

rather than empirical data.

Appliances produced at some future date may have different

lifetimes than those in the same class produced in the past. The

projections of lifetimes and other parameters used in the analysis

should be based on observed empirical trends, as well as expert

knowledge of likely changes in the industry, since future changes are

not always straight-line projections of past trends. While expert

judgement is crucial, however, it must have a strong empirical basis.

With this in mind, the Department believes that the probability

distribution of equipment lifetime used in the analysis is the most

sound, given available evidence of past performance and recent trends.

Because none of the data on equipment lifetime indicates a relationship

between efficiency and lifetime, the Department assumes that equipment

lifetime is independent of efficiency.

EMPA claimed that lifetime should be based on first ownership

rather than actual equipment life. (Glenn Schleede, EMPA, Transcript,

pp 232; EMPA, #3) They stated that homeowners usually change residences

every 7 years. In response to this assertion, it was stated that

although the statute requires that LCC be determined it does not

specify the exact meaning of lifetime. (Mike Rivest, ADL, Transcript, p

236) Counter to EMPA's claims, OOE stated that energy efficiency

benefits are essentially swapped when a homeowner changes residence.

(Charlie Stephens, OOE, Transcript, pp 233; OOE, #7) That is, the new

homeowner will realize the benefits of the first owner's more efficient

equipment. They also add that an equipment lifetime of 15 years seems

reasonable for split system air conditioners, but that field data

indicates that heat pumps have a shorter life.

The Department believes that equipment life rather than first

ownership is the correct measure of lifetime. The Department continues

to seek any additional information that may provide better data on

actual air conditioner and heat pump life.

Discount Rate: Interested parties submitted several comments

recommending values or procedures for determining discount rates. An

industry representative suggested that rates of 18 to 20% may be

appropriate as consumers are paying off credit card debt at these

rates. (Jim Crawford, Trane, Transcript, p 237) He also asserted that

practical (i.e., implicit) discount rates (which are derived from

analyzing actual consumer behavior) may be on the order of 30%. EEI

also believes that credit card interest rates should be used as a basis

for establishing discount rates. (EEI, #2) EMPA believes DOE's discount

rates (as presented at the 1998 Framework Workshop) are too high and

based on faulty assumptions. They stated that discount rates should

reflect the true cost of money that consumers would have to spend to

purchase more efficient appliances. (EMPA, #3) Industry representatives

also stated that questions concerning consumer discount rates should be

included on any market surveys for determining retail prices and that

DOE needs to take into account any information supplied by the

industry's trade association, ARI. (Jim Crawford, Trane, Transcript, p

243; David Lewis, Lennox, Transcript, pp 243-244)

In contrast to these comments, OOE believes that prior discount

rates developed by DOE seem reasonable, although there are differences

in how consumers purchase air conditioner and heat pump equipment

compared to how they purchase other appliances. (OOE, #7) They strongly

disagreed that discount rates in excess of 15% might be appropriate.

They claim such high rates are based on calculating an

[[Page 66322]]

implicit discount rate or market failure factor based on past

shipments.

The Department's Process Rule for establishing new or revised

energy efficiency standards for consumer products describes how real

discount rates are to be established for residential consumers, as

follows:

For residential and commercial consumers, ranges of three

different real discount rates will be used. For residential

consumers, the mid-range discount rate will represent DOE's

approximation of the average financing cost (or opportunity costs of

reduced savings) experienced by typical consumers. Sensitivity

analyses will be performed using discount rates reflecting the costs

more likely to be experienced by residential consumers with little

or no savings and credit card financing and consumers with

substantial savings.

Based on the Department's guidelines provided in the Process Rule,

a distribution of discount rates was derived to reflect the variability

in financing methods consumers use in purchasing central air

conditioners and heat pumps. The real interest rate associated with

financing an appliance purchase is a good indicator of the additional

costs incurred by consumers who pay a higher first cost, but enjoy

future savings, although it is not the only indicator of such costs.

While the method used to derive this distribution relies on a number of

uncertain assumptions regarding the financing methods used by

consumers, DOE believes that the resulting distribution of discount

rates encompasses the full range of discount rates that are appropriate

to consider in evaluating the impacts of DOE standards on consumers

(i.e., values represented by the mid-range financing cost, consumers

with no savings, and consumers with substantial savings), as well as

all the discount rates which fall between the high and low extreme

values.

The method of purchase used by consumers is assumed to be

indicative of the source of the funds and the type of financing used,

although DOE is not aware of detailed research into this relationship.

Consumers purchase appliances as parts of new homes (mortgages) and as

separate retail purchases. Retail purchases are paid by cash, credit

cards, or loans. In the case of space-conditioning equipment, the loans

are assumed to take the form of second mortgages, as central air

conditioner and heat pump purchases often occur when home upgrades are

made. Based upon recommendations provided by the ARI, the shares of the

different financing mechanisms used for purchasing central air

conditioners and heat pumps were assumed to be 30% with a new home

(first mortgages), 25% through loans (second mortgages), 10% paid by

cash, and 35% by use of credit cards.

In order to derive a full distribution of discount rates, DOE

estimated a range of interest rates, based on historical data and

judgments of future trends, for different types of consumer savings or

financing.

For new housing, the Department based its real mortgage rates on

ARI's suggested mean value of 3.0% and assumed a range of 1.6 to 4.4%.

Applying an assumed marginal tax rate of 28% (i.e., the maximum

marginal rate paid by most U.S. taxpayers) and an assumed inflation

rate of 2% results in a mean nominal mortgage rate of 6.94% with a

range of 5.0 to 8.89%.

For second mortgages or loans, ARI suggested a mean real interest

rate of 8.0%. This rate is more representative of a nominal rate for

second mortgages and was used as such. Assuming a tax rate of 28%, then

subtracting an assumed inflation rate of 2% (the same rates used to

derive the new home real interest rates) we arrive at a mean real

interest rate of 3.76%. Nominal minimum and maximum interest rates of

6% and 10% were assumed to arrive at the real interest rate range of

2.32% to 5.20%.

For cash, the minimum rate was assumed to equal 0%. This rate

applies to purchasers making cash purchases without withdrawing from

savings accounts. Based upon ARI's recommendation, the maximum is taken

to be the opportunity cost represented by the interest that could have

been earned in a typical mutual fund (assumed to be 6% real). A real

mean rate of 3% results.

For credit cards, the Department based its real interest rate on

ARI's suggested mean value of 12.5%. Minimum and maximum real rates of

6% and 19% were assumed. It should be noted that the use of these

credit card rates reflects an assumption that all consumers who use

credit cards do so as a means of long term financing for product

purchases, rather than as simply a convenient method of purchase or as

a means of short term financing.

Combining the assumed shares of each financing method, the above

real interest rates result in a weighted-average (mean) value of 6.51%

and a distribution that varies from 0 to 19%. Sensitivity studies show

that while the LCC results are sensitive to the value chosen for mean

discount rate, the LCC results are not sensitive to the distribution of

discount rates.

The Department believes that the above method is a valid basis for

establishing a distribution of discount rates over the full range of

discount rates relevant to most purchasers of the products covered by

this rulemaking, but acknowledges that different assumptions might be

made about likely interest, inflation and marginal tax rates, or about

consumer financing methods, and that different approaches to

identifying valid consumer discount rates might also be valid. For

example, it is also possible to base consumer discount rates on the

average real rates of return on consumer investment or other measures

of the opportunity costs incurred by consumers that purchase the

covered products. DOE does not believe, however, that such alternative

assumptions or alternative approaches would significantly alter the

range of discount rates used by the Department or the conclusions drawn

from the life cycle cost analyses conducted using these discount rates.

The Department is seeking any information that would support

significant alterations in the range or distribution of the discount

rates derived from DOE's analysis. Alternatively, DOE is soliciting

comment on the possible use of a standardized distribution of discount

rates ranging from approximately 4% to 12%, with a mean of 6%. The use

of such a standardized distribution would explicitly recognize the many

uncertainties associated with DOE's current analysis and, based on

sensitivity analyses already performed by DOE, such a standardized

distribution would not significantly alter the conclusions of DOE's

life cycle cost analyses.

Repair Costs: The annual repair cost covers the replacement or

repair of components which have failed. The Department assumed repair

costs for minimum efficiency equipment (10 SEER) and equipment with

efficiencies greater than 12 SEER were equal one-half the equipment

price divided by the mean equipment lifetime. The Department assumed

equipment with efficiencies of 11 and 12 SEER incur a 1% increase in

repair cost over the minimum efficiency (10 SEER) level. The rationale

for assuming essentially flat repair costs through efficiencies up to

and including 12 SEER pertains to the level of technology being used at

these system efficiency levels. Through 12 SEER, system technology

generally does not incorporate sophisticated electronic components

which are believed to incur higher repair costs. Increases in SEER are

generally achieved through more efficient single-speed compressors or

more efficient and/or larger heat exchanger coils. Systems with

[[Page 66323]]

efficiencies beyond 12 SEER start to incorporate modulating blowers or

compressors which are generally believed to be more susceptible to

failure.

Maintenance Costs: The annual maintenance cost covers such items as

checking and maintaining refrigerant charge levels and cleaning heat

exchanger coils. Data from Service Experts, an HVAC service company,

were used to establish maintenance costs. The maintenance cost ranges

from $0 to $135 with a weighted-average value of $36.

EMPA stated that DOE needs to collect and include extended warranty

and service costs in LCC calculations. (Glenn Schleede, EMPA,

Transcript, p 231; EMPA, #3) EMPA also requested that the assumptions

regarding maintenance and repair costs be reevaluated and described in

greater detail. An industry representative supported including these

costs, and also stated that they will be a function of equipment

efficiency. (David Lewis, Lennox, Transcript, p 231) A suggestion was

made to include questions on warranty and service costs on any market

survey for determining retail prices (Steven Nadel, ACEEE, Transcript,

p 232). OOE endorsed the concept of accounting for differences in

maintenance, service, and installation costs, provided these

incremental costs are attributable only to equipment at different

efficiency levels (OOE, #7).

Although the Department included maintenance costs in its LCC

calculations, no attempt was made to account for warranty costs. The

Department assumed that warranty costs are constant with increased

efficiency and, thus, there was no need to explicitly account for

warranty costs. The Department welcomes any comments that can provide

insight as to how warranty costs should be accounted for in the LCC

Analysis.

ii. Equipment Prices

How manufacturing costs and profit margins associated with

standards are passed through from manufacturers to consumers has an

impact on both consumers and manufacturers. Consumer and manufacturer

economics are linked and inversely related. For this reason, equipment

purchase prices used for the LCC Analysis need to be reconciled with

manufacturer costs.

At the pre-ANOPR stage, a consumer LCC curve, based in part on mean

installed consumer costs, is a significant factor in the initial

selection of potential standards levels. Total installed costs are

needed for a base case, absent new standards, and for all efficiency

levels to be considered. As noted earlier, equipment purchase price

coupled with the installation price equals the total installed consumer

cost.

There was a great deal of discussion at the 1998 Framework Workshop

concerning equipment or retail prices, because equipment prices were

being viewed as a means to verify industry-supplied manufacturer cost

data. Much of the discussion focused on the correlation between

manufacturer costs and prices. Some claimed that there is practically a

random relationship between manufacturer costs and prices and that

prices are based more upon market dynamics rather than improvements in

equipment efficiency. (Jim Crawford, Trane, Transcript, pp 90, 139-140)

It was also stated that, due to the tremendous variability in city

size, dealer groups, dealer size, dealer proximity to warehouses, bulk

purchasing, and national account purchasing, the markups involved in

converting manufacturer costs to retail prices are highly variable.

Also, because some manufacturers use distributors while others do not,

markups can vary significantly from manufacturer-to-manufacturer.

(David Lewis, Lennox, Transcript, pp 168-170) It was also noted that

markups are unlikely to be constant across all efficiencies. (Jim

Crawford, Trane, Transcript, pp 154)

In order better to determine equipment prices, participants at the

Workshop agreed that it would be appropriate to conduct a market

survey. There was discussion as to whether the survey should be

administered to contractors or consumers. It was pointed out that

contractors may not provide true prices as they may not want to reveal

their profit margins while consumers may simply not know the price of

only the equipment (i.e., the price exclusive of the labor, materials

and profit for installation). (Transcript, pp 170-186) With regard to

price data that may be collected from utilities, some of it might be

distorted due to demand side management (DSM) incentive programs, more

specifically rebate programs. The price collected may not be the actual

price of the equipment, but rather, the price after a rebate has been

applied. (Steve Rosenstock, EEI, Transcript, pp 190)

In written comments, EEI stated that there is little correlation

between manufacturer costs and retail prices, and that market surveys

of customers, utilities, and contractors will likely provide the best

information on retail prices. (EEI, #2) EMPA claimed that price data

collected will likely not reflect conditions in the current market.

(EMPA, #3) EMPA also stated that DOE should not shift the

responsibility of collecting and providing data to interested parties.

ACEEE noted two possible data sources: a 1996 Xenergy report and

Chris Neme at the Vermont Energy Investment Fund in Burlington, VT.

(ACEEE, #5) OOE suggested that two methods are needed for deriving

prices, each as a cross-check on the results of the other. (OOE, #7)

One approach should be a ``mark-up'' of manufacturer costs which yield

a range of retail prices. A market survey of equipment prices should be

used as the second approach, as opposed to a survey of market experts

trying to predict consumers' willingness to pay at various price

levels. With regard to current market prices, PG&E believes that split

system air conditioning equipment that exceeds 10 SEER are available at

competitive prices with 12 SEER systems being readily available. (PG&E,

#8)

For the pre-ANOPR Analysis, the Department did not attempt to

conduct a comprehensive contractor or consumer survey of equipment

prices. The primary reasons were the complexity of and the time needed

for a comprehensive survey, and the short time frame allotted by the

Department for publishing the Supplemental ANOPR. The Department will

consider conducting a survey for any updates to the analyses conducted

for the NOPR.

On November 30, 1998, however, the Department issued a Federal

Register Notice (63 FR 65767) requesting comments on a proposal to

survey retail prices for Central Air Conditioners and Heat Pumps. ARI

responded to that request by submitting comments. The comments asserted

that the proposed survey is woefully inadequate, given the number of

variables involved. (ARI, #9) ARI suggested that, at a minimum, data on

the following factors should be considered: (1) Three capacity sizes

(1.5, 3, and 5 tons), (2) five efficiency levels (10, 11, 12, 13, 14

SEER), and (3) four classes (split and single package air-conditioner/c

and heat pump). The survey should be weighted to reflect regional sales

markets and a large number of manufacturers should be represented in

the survey. In addition, there should be no reason to include questions

on the impact of utility rebates, as they are dwindling rapidly.

The Department uses various assumptions about cost pass-through

that are reflected in the price forecast approach. The output of this

analysis is a table describing retail prices for each possible

efficiency level, assuming that each level represents a new minimum

efficiency standard. Consistent with the

[[Page 66324]]

process rule, and building on the estimates generated by the various

assumptions, projected retail prices are described within a range of

uncertainty.

Purchase prices of baseline equipment were determined by estimating

manufacturing costs and applying appropriate markups along the

distribution chain. Markups were determined in two ways: through

surveys of distributor (wholesale) and retail prices, and through

publicly available financial reports. For about 90% of residential air

conditioning equipment, the distribution chain includes manufacturers,

distributors (wholesalers), and dealers (contractors). Equipment

purchase prices are thus estimated as the product of manufacturing

cost, manufacturer markup, distributor markup, dealer markup, and sales

tax.

For the determination of markups via financial reports, it was

assumed that product markups equal gross margin less pre-tax profit

margin (earnings-before-taxes) and outbound freight of 6%, plus 1%. The

baseline central air conditioner and heat pump units covered by this

analysis typically have lower margins than other products handled by

diversified companies. The values for markups given in the next

paragraphs may change in future stages of analysis as the underlying

data are improved and cross-checked.

Manufacturer Markup: Financial reports from five publicly traded

air conditioner manufacturers, representing 75% of the market, were

examined for a five-year period (1993-1997). Five-year average markups

for the two most dependent on air conditioner sales were 1.18 and 1.17

respectively. The other three companies are more diversified and, as

expected, exhibited higher markups--1.25, 1.24, and 1.18 respectively.

A central value of 1.18 was chosen for the Price Analysis, with a range

of 1.15 to 1.26, based on the lowest and highest markups for the five

manufacturers for the five-year period.

Distributor Markup: Five-year average markups for the 500 members

of the Air-conditioning and Refrigeration Wholesalers (ARW) were 1.37,

the same as for 1997. This value was used for the analysis. However,

since margins for after-market parts are substantially higher than

margins for baseline equipment, the actual markup on baseline equipment

is likely to be lower than the assumed value of 1.37. The markup value

may be revised downwards based on future information.

Dealer Markup: Markups were calculated for contractors represented

by the Air Conditioning Contractors of America (ACCA) and two

contractor consolidators that focus on the residential market.

Information used from ACCA covered ``residential and light commercial''

dealers, and was divided into new and retrofit services, with markups

of 1.41 and 1.63, respectively. The weighted average markup for ACCA

was 1.55 (based on 66 percent of all sales being retrofit sales), close

to the markup of 1.54 for one of the contractor consolidators. The

markup for the other consolidator was 1.38, but half of its revenues

come from plumbing, electrical, and other services that typically have

lower margins. A central value of 1.55 was chosen for the Price

Analysis, with a range of 1.37 (based on information from ICF

Consulting on equipment markups for direct replacement) to 1.63.

Sales Tax: In many cases, local and state sales taxes are applied

to equipment purchases. Using 1997 state and local sales tax data and

1994 state unitary shipment data, the Department calculated a

distribution of combined sales tax rates. Although the distribution

revealed a small percentage of consumers at tax rates of 0% and 10%,

the effective distribution was triangular with a mean of 6.7% and a

range from 5% to 8%. This corresponds to a mean markup of 1.07 with a

range from 1.05 to 1.08.

Overall Markup: Equipment purchase price is determined by

multiplying manufacturer cost and overall markup. Mean values and

ranges for the overall markup are the products of the mean values and

ranges for manufacturer markup, distributor markup, dealer markup and

sales tax. The mean overall markup is thus calculated as 2.68, with a

range of 2.27 to 3.04.

iii. Payback Analysis (Distribution of Paybacks)

Payback is calculated based on the same inputs used for the LCC

Analysis with the difference that the payback values are based on first

year savings achieved after the standard takes effect. The output of

the analysis is a distribution of payback periods. The mean payback

period is also reported. Additional information is available in the LCC

spreadsheet which is posted to the Department's web site. The data

includes charts of cash flow taking into account the changing annual

fuel prices.

iv. Rebuttable Payback

As discussed previously, EPCA established a rebuttable presumption

that a standard is economically justified if the additional product

purchase cost attributed to the standard is less than three times the

value of the first year energy cost savings, which is equivalent to a

three year simple payback. The calculation of rebuttable payback is

based on single point-values instead of probability distributions used

in the LCC analysis. For example, where a probability distribution of

electricity prices are used in the distributional Payback Analysis,

only the weighted-average value from the probability distribution of

electricity prices is used for the determination of the Rebuttable

payback.

Other than the use of single point-values, the most notable

difference between the two payback analyses is the Rebuttable payback's

reliance on the DOE test procedure to determine a central air

conditioner's or heat pump's annual energy consumption. The DOE test

procedure for central air conditioners and heat pumps in the cooling

season uses the following expression to calculate the annual space-

cooling energy consumption:

Space-Cooling Annual Energy Use = (Cooling Capacity SEER) x

Hours

where the Hours equal 1000, the assumed annual operational hours of the

space-cooling equipment.

The DOE test procedure for the heating season performance of heat

pumps uses the following expression to calculate the annual space-

heating energy consumption:

Space-Heating Annual Energy Use = (DHR HSPF) x 0.77 x

Hours

where DHR equals the design heating requirement (which for 3-ton

cooling capacity heat pumps is typically 35,000 Btu/hr) and Hours equal

2080, the assumed seasonal operational hours of the space-heating

equipment.

The annual space-cooling and heating energy consumption calculated

based on the previous equations from the DOE test procedure are on the

order of 50% greater than the weighted-average values from the 1993

RECS. This means that the payback value calculated from the DOE test

procedure equations will be significantly lower than the average

payback value calculated from the RECS analysis, for any standard

level.

Rebuttable payback periods are first calculated between the new

standard level being analyzed and each central air conditioner or heat

pump efficiency being sold in the year 2006. The paybacks are then

weighted and averaged according to the percentage of each equipment

efficiency sold before a new standard is enacted. Rather than being

based on probability distributions, single point values are used for

the input variables. These values (e.g., operating hours per year) will

correspond to those defined in the DOE

[[Page 66325]]

test procedure. The result is a single-value of payback and not a

probability distribution. The payback is calculated for the expected

effective year of the standard (e.g., 2006). Examples and further

details are presented in the Preliminary TSD.

Based on the most recently available shipments data from ARI (from

1994), Table 13 shows the markets shares by efficiency level for each

of the four product classes being analyzed.

Table 13.--Efficiency Level Market Shares

[In percent]

----------------------------------------------------------------------------------------------------------------

Single Single

SEER Split A/C Split HP package A/C package HP

----------------------------------------------------------------------------------------------------------------

10.............................................. 78.7 59.3 82.3 64.2

11.............................................. 5.4 15.0 9.7 13.6

12.............................................. 12.0 19.7 6.8 22.2

13.............................................. 3.6 4.5 1.2 0.0

14.............................................. 0.1 1.0 0.0 0.0

15.............................................. 0.2 0.5 0.0 0.0

----------------------------------------------------------------------------------------------------------------

Because the shipment-weighted efficiencies of unitary air conditioners

and heat pumps has remained essentially flat over the four year period

from 1994 to 1997, the previous market shares in Table 13 for 1994 are

assumed to be applicable for the year 2006. If available, data on a

forecasted distribution of equipment efficiencies in the year 2006 will

be used to refine these calculations for the NOPR Analysis.

2. Preliminary Results

a. General

Calculation of LCC captures the tradeoff between the increases in

purchase price and reductions in operating expenses for increasing

efficiencies of appliances. In addition, two other measures of economic

impact are calculated: distributions of payback periods and a payback

period calculated for purposes of the rebuttable presumption clause.

The outputs of the LCC spreadsheet include probability distributions

and single-point average values of the impacts for each energy

efficiency level compared to the baseline. A distinct advantage of

modeling based on probability distributions is that the percentage of

consumers achieving LCC savings or attaining certain payback periods

due to an increased efficiency standard can be identified. A variety of

graphic displays can illustrate the implications of the analysis

results. These include: (1) A cumulative probability distribution

showing the percentage of U.S. households that would have a net saving

by owning a more energy-efficient appliance, and (2) a chart depicting

the variation in LCC for each efficiency level considered.

b. Product Specific

The following LCC results show the mean LCCs associated with the

standard levels which were analyzed. In addition, the percent of

households with reduced LCCs relative to current minimum efficiency

equipment (10 SEER) are provided. LCC results are provided based upon

the manufacturer cost estimates from the efficiency-level approach

(section II C.1.b.i.) and the reverse engineering (section

II.C.1.b.ii.). LCC results are presented for nominal 3-ton capacities

for the four primary product classes, i.e., split-type air

conditioners, split-type heat pumps, single-package air conditioners,

and single-package heat pumps (See Tables 14 to 17). Since the values

of most inputs are uncertain and are represented by probability

distributions of values rather than discrete values, the results

presented in the Preliminary TSD (which describes the analytic results

in greater detail) are also described by probability distributions.

Table 14.--Split-Type Air Conditioners--LCC Results

----------------------------------------------------------------------------------------------------------------

Source of manufacturing cost data

---------------------------------------------------------------

Industry Reverse engineering

SEER ---------------------------------------------------------------

Percent with Percent with

Mean LCC lower LCC Mean LCC lower LCC

----------------------------------------------------------------------------------------------------------------

10.............................................. $4,837 .............. $4,828 ..............

11.............................................. 4,827 39 4,786 48

12.............................................. 4,886 31 4,770 45

13.............................................. 5,229 12 4,931 27

14.............................................. 5,659 6 5,246 15

15.............................................. 6,052 4 5,456 11

16.............................................. .............. 2 5,533 11

17.............................................. .............. .............. 5,672 10

----------------------------------------------------------------------------------------------------------------

[[Page 66326]]

Table 15.--Split-Type Heat Pumps--LCC Results

----------------------------------------------------------------------------------------------------------------

Source of manufacturing cost data

---------------------------------------------------------------

Industry Reverse engineering

SEER / HSPF ---------------------------------------------------------------

Percent with Percent with

Mean LCC lower LCC Mean LCC lower LLC

----------------------------------------------------------------------------------------------------------------

10 / 6.8........................................ $10,086 .............. $10,001 ..............

11 / 7.1........................................ 9,915 74 9,695 99

12 / 7.4........................................ 9,852 63 9,533 90

13 / 7.7........................................ 10,119 36 9,850 49

14 / 8.0........................................ 10,311 28 10,246 27

15 / 8.2........................................ 11,079 11 10,534 20

16 / 8.2........................................ .............. .............. 10,679 18

----------------------------------------------------------------------------------------------------------------

Table 16.--Single Package Air Conditioners--LCC Results

----------------------------------------------------------------------------------------------------------------

Source of manufacturing cost data

---------------------------------------------------------------

Industry Reverse engineering

SEER ---------------------------------------------------------------

Percent with Percent with

Mean LCC lower LCC Mean LCC lower LCC

----------------------------------------------------------------------------------------------------------------

10.............................................. $5,341 .............. $5,324 ..............

11.............................................. 5,429 20 ..............

12.............................................. 5,433 26 5,194 58

13.............................................. 6,031 5 5,598 17

14.............................................. 6,362 4 .............. ..............

15.............................................. 6,921 2 .............. ..............

----------------------------------------------------------------------------------------------------------------

Table 17.--Single Package Heat Pumps--LCC Results

----------------------------------------------------------------------------------------------------------------

Source of manufacturing cost data

---------------------------------------------------------------

Industry Reverse engineering

SEER ---------------------------------------------------------------

Percent with Percent with

Mean LCC lower LCC Mean LCC lower LCC

----------------------------------------------------------------------------------------------------------------

10 / 6.8........................................ $10,025 .............. $9,912 ..............

11 / 7.1........................................ 9,906 61 .............. ..............

12 / 7.4........................................ 9,835 58 9,551 80

13 / 7.7........................................ 10,342 22 .............. ..............

14 / 8.0........................................ 10,425 21 .............. ..............

15 / 8.2........................................ 11,031 10 .............. ..............

----------------------------------------------------------------------------------------------------------------

Tables 18 to 21 show the median payback periods associated with

each standard level. To note, the median value of a distribution has an

equal number of payback periods that are greater than and less than the

reported value. As with the LCC results, payback periods are provided

based upon both the manufacturer cost estimates from the industry and

from the reverse engineering analysis. Payback period results are

presented for the four primary product classes; split-type air

conditioners, split-type heat pumps, single-package air conditioners,

and single-package heat pumps.

Table 18.--Split-type Air Conditioners--Median Payback Periods

[In years]

------------------------------------------------------------------------

Source of manufacturing

cost data

SEER -------------------------

Reverse

Industry engineering

------------------------------------------------------------------------

11............................................ 13 10

12............................................ 15 11

13............................................ 41 20

14............................................ 80 35

15............................................ 137 43

16............................................ ........... 46

17............................................ ........... 49

------------------------------------------------------------------------

Table 19.--Split-type Heat Pumps--Median Payback Periods

[In years]

------------------------------------------------------------------------

Source of manufacturing

cost data

-------------------------

Reverse

Industry engineering

------------------------------------------------------------------------

11/7.1........................................ 6 1

12/7.4........................................ 8 3

13/7.7........................................ 13 10

14/8.0........................................ 17 17

15/8.2........................................ 31 21

16/8.4........................................ ........... 22

------------------------------------------------------------------------

[[Page 66327]]

Table 20.--Single Package Air Conditioners--Median Payback Periods

[In years]

------------------------------------------------------------------------

Source of manufacturing

cost data

SEER -------------------------

Reverse

Industry engineering

------------------------------------------------------------------------

11............................................ 20 ...........

12............................................ 17 8

13............................................ 84 30

14............................................ 133 ...........

15............................................ 559 ...........

------------------------------------------------------------------------

Table 21.--Single Package Heat Pumps--Median Payback Periods

[In years]

------------------------------------------------------------------------

Source of manufacturing

cost data

SEER/HSPF -------------------------

Reverse

Industry engineering

------------------------------------------------------------------------

11/7.1........................................ 8 ...........

12/7.4........................................ 9 5

13/7.7........................................ 20 ...........

14/8.0........................................ 20 ...........

15/8.2........................................ 31 ...........

------------------------------------------------------------------------

Tables 22 to 25 show the simple paybacks for purposes of the

rebuttable presumption clause. This means test procedure assumptions

are followed for central air conditioners and heat pumps.

Table 22.--Split-Type Air Conditioners--Simple Payback

[In years]

------------------------------------------------------------------------

Source of manufacturing

cost data

SEER -------------------------

Reverse

Industry engineering

------------------------------------------------------------------------

11............................................ 6.2 5.0

12............................................ 7.6 5.4

13............................................ 13.7 7.8

14............................................ 20.9 12.7

15............................................ 26.8 14.7

16............................................ ........... 14.6

17............................................ ........... 15.4

------------------------------------------------------------------------

Table 23.--Split-Type Heat Pumps--Simple Payback

[In years]

------------------------------------------------------------------------

Source of manufacturing

cost data

SEER/HSPF -------------------------

Reverse

Industry engineering

------------------------------------------------------------------------

11/7.1........................................ 3.2 0.4

12/7.4........................................ 4.2 1.8

13/7.7........................................ 6.8 5.6

14/8.0........................................ 8.0 8.8

15/8.2........................................ 13.8 10.5

16/8.4........................................ ........... 10.8

------------------------------------------------------------------------

Table 24.--Single Package Air Conditioners--Simple Payback

[In years]

------------------------------------------------------------------------

Source of manufacturing

cost data

SEER -------------------------

Reverse

Industry engineering

------------------------------------------------------------------------

11............................................ 9.9 ...........

12............................................ 8.5 3.8

13............................................ 21.2 11.2

14............................................ 25.2 ...........

15...............................

This text is long and has been trimmed here. Open the source document for the complete record.

This is a copy of a public record, reproduced as it was published. It is not legal advice, and it may not be the version a court would rely on. Check the official source before you cite it.

A word about cookies

We need a few to keep you signed in and the library working. The rest help us see which pages people use and where they get stuck. They stay off unless you say yes.