Southwest Research Institute, Applications for Renewal and Expansion of Recognition

Federal RegisterNov 10, 1998

Ask Donna

What actually matters in this document.

Text

DEPARTMENT OF LABOR

Occupational Safety and Health Administration

[Docket No. NRTL-3-90]

Southwest Research Institute, Applications for Renewal and

Expansion of Recognition

AGENCY: Occupational Safety and Health Administration (OSHA), Labor.

ACTION: Notice.

-----------------------------------------------------------------------

SUMMARY: This notice announces the applications of Southwest Research

Institute for renewal and for expansion of its recognition as a

Nationally Recognized Testing Laboratory under 29 CFR 1910.7, and

presents the Agency's preliminary finding. This preliminary finding

does not constitute an interim or temporary approval of these

applications.

DATES: Comments submitted by interested parties must be received no

later than January 11, 1999.

ADDRESSES: Send comments concerning this notice to: Office of Technical

Programs and Coordination Activities, NRTL Program, Occupational Safety

and Health Administration, U.S. Department of Labor, 200 Constitution

Avenue, NW, Room N3653, Washington, DC 20210.

FOR FURTHER INFORMATION CONTACT: Bernard Pasquet, Office of Technical

Programs and Coordination Activities, NRTL Program, at the above

address, or phone (202) 219-7056.

SUPPLEMENTARY INFORMATION:

Notice of Application

The Occupational Safety and Health Administration (OSHA) hereby

gives notice that Southwest Research Institute (SwRI) has applied for

renewal and for expansion of its current recognition as a Nationally

Recognized Testing Laboratory (NRTL). SwRI's expansion request covers

the use of additional test standards. OSHA recognizes an organization

as an NRTL, and processes applications related to such recognitions,

following requirements in Sec. 1910.7 of Title 29, Code of Federal

Regulations (29 CFR 1910.7). Appendix A to this section requires that

OSHA publish this public notice of the preliminary finding on an

application.

When first recognized, OSHA identified the Department of Fire

Technology as the SwRI unit to which the recognition would, and still

does, apply. The renewal and expansion will continue to apply primarily

to this part of SwRI, although part of the recognition, such as the

requirement for independence, applies to SwRI as a whole.

[[Page 63087]]

SwRI's previous application as an NRTL covered its recognition as

an NRTL (57 FR 30237, July 8, 1992), which OSHA granted on the date

noted below.

The current address of the SwRI testing facility already recognized

by OSHA is: Southwest Research Institute, Department of Fire

Technology, 6620 Culebra Road, Post Office Drawer 28510, San Antonio,

Texas 78228.

General Background on the Applicant and Applications

According to publicly available information, SwRI is an

``independent, nonprofit, applied engineering and physical sciences

research and development organization * * *'' In addition, SwRI has

``12 technical divisions,'' one of which is the Chemistry and Chemical

Engineering Division. This division includes the Department of Fire

Technology.

SwRI has submitted a request for renewal of its recognition, dated

October 1, 1997 (see Exhibit 6A). SWRI received its recognition as an

NRTL on July 13, 1993 (58 FR 37752), for a period of five years ending

July 13, 1998. Appendix A to 29 CFR 1910.7 stipulates that the period

of recognition of an NRTL is five years and that an NRTL may renew its

recognition by applying not less than nine months, nor more than one

year, before the expiration date of its current recognition. SwRI has

submitted its request within the time allotted, and retains its

recognition pending OSHA's final decision in this renewal process.

SwRI has also submitted a request, dated October 1, 1997 (see

Exhibit 6B) to expand its recognition for additional test standards.

However, OSHA has determined that some of the standards that were

requested are not appropriate, as prescribed by 29 CFR 1910.7(c).

Therefore, OSHA does not intend to include these standards for

recognition.

Renewal of Recognition

SwRI seeks renewal of its recognition for testing and certification

of products to demonstrate compliance to the following 7 test

standards, which OSHA has previously recognized for SwRI:

UL 10A Tin-Clad Fire Doors

ANSI/UL 10B Fire Tests of Door Assemblies

ANSI/UL 94 Tests for Flammability of Plastic Materials for Parts in

Devices and Appliances

ANSI/UL 155 Tests of Fire Resistance of Vault and File Room Doors

ANSI/UL 555 Fire Dampers

ANSI/UL 910 Test Method for Fire and Smoke Characteristics of

Electrical and Optical-Fiber Cables Used in Air Handling Spaces

ANSI/UL 1887 Fire Test of Plastic Sprinkler Pipe for Flame and Smoke

Characteristics

The designations and titles of the above test standards were

current at the time of the preparation of this notice. They may differ

from those that OSHA used in the original recognition of the test

standards published in the Federal Register. In addition, OSHA had

recognized SwRI for ASTM E152 but the standards organization has since

withdrawn this standard. As a result, this standard is not included in

SwRI's renewal. The standards organization has indicated that it is

working on a replacement standard.

Expansion of Recognition--Additional Test Standards

SwRI seeks recognition for testing and certification of products to

demonstrate compliance to the following 3 test standards, and OSHA has

determined the standards are appropriate, as prescribed by 29 CFR

1910.7(c). OSHA recognition of any NRTL for a particular test standard

is limited to products for which OSHA standards require third party

testing and certification before use in the workplace.

UL 162 Foam Equipment and Liquid Concentrates

ANSI/UL 711 Rating and Fire Testing of Fire Extinguishers

UL 2085 Insulated Aboveground Tanks for Flammable and Combustible

Liquids

Preliminary Finding on the Applications

SwRI has submitted acceptable requests for renewal and expansion of

its recognition as an NRTL. In connection with the requests, OSHA has

performed an on-site review of the SwRI facility in San Antonio, Texas,

on March 30-April 2, 1998. The review focused on the testing and

certification activities performed by the Department of Fire Technology

in its capacity as an NRTL. Discrepancies noted by the auditor during

the on-site review were addressed by SwRI following the on-site

evaluation and are included in the on-site review report (see Exhibit

7).

Following a review of the application file, the on-site review

report, and other pertinent documents, the NRTL Program staff has

concluded that OSHA can grant to the SwRI Department of Fire Technology

facility in San Antonio, Texas: (1) The renewal of recognition for the

test standards noted above, and (2) the expansion to use the additional

3 test standards. The staff therefore recommended to the Assistant

Secretary that the applications be preliminarily approved.

Based upon the recommendation of the staff, the Assistant Secretary

has made a preliminary finding that the SwRI Department of Fire

Technology San Antonio, Texas can meet the recognition requirements, as

prescribed by 29 CFR 1910.7, for the renewal and the expansion of

recognition. This preliminary finding does not constitute an interim or

temporary approval of the applications.

OSHA welcomes public comments, in sufficient detail, as to whether

SwRI has met the requirements of 29 CFR 1910.7 for the renewal and

expansion of its recognition as a Nationally Recognized Testing

Laboratory. Your comment must consist of pertinent written documents

and exhibits. To consider it, OSHA must receive the comment at the

address provided above (see ADDRESS), no later than the last date for

comments (see DATES above). You may obtain or review copies of SwRI's

requests, the on-site review report, and all submitted comments, as

received, by contacting the Docket Office, Room N2625, Occupational

Safety and Health Administration, U.S. Department of Labor, at the

above address. You should refer to Docket No. NRTL-3-90, the permanent

record of public information on SwRI's recognition.

The NRTL Program staff will review all timely comments, and after

resolution of issues raised by these comments, will recommend whether

to grant SwRI's renewal and expansion requests. The Assistant Secretary

will make the final decision on granting the renewal and expansion, and

in making this decision, may undertake other proceedings that are

prescribed in Appendix A to 29 CFR 1910.7. OSHA will publish a public

notice of this final decision in the Federal Register.

Signed at Washington, DC, this 28th day of October, 1998.

Charles N. Jeffress,

Assistant Secretary.

[FR Doc. 98-30114 Filed 11-9-98; 8:45 am]

BILLING CODE 4510-26-U

This is a copy of a public record, reproduced as it was published. It is not legal advice, and it may not be the version a court would rely on. Check the official source before you cite it.

A word about cookies

We need a few to keep you signed in and the library working. The rest help us see which pages people use and where they get stuck. They stay off unless you say yes.