National Emission Standards for Hazardous Air Pollutants: Oil and Natural Gas Production and Natural Gas Transmission and Storage

Federal RegisterFeb 6, 1998

Ask Donna

What actually matters in this document.

Text

SUMMARY: These proposed national emission standards for hazardous air

pollutants (NESHAP) would limit emissions of hazardous air pollutants

(HAP) from oil and natural gas production and natural gas transmission

and storage facilities. These proposed rules would implement section

112 of the Clean Air Act (Act) and are based on the Administrator's

determination that oil and natural gas production and natural gas

transmission and storage facilities emit HAP identified on the EPA's

list of 188 HAP.

The EPA estimates that approximately 65,000 megagrams per year (Mg/

yr) of HAP are emitted from major and area sources in these source

categories. The primary HAP emitted by the facilities covered by these

proposed standards include benzene, toluene, ethyl benzene, mixed

xylenes (collectively referred to as BTEX), and n-hexane. Benzene is

carcinogenic and all can cause toxic effects following exposure. The

EPA estimates that these proposed NESHAPs would reduce HAP emissions in

the oil and natural gas production source category by 57 percent and in

the natural gas transmission storage source category by 36 percent.

Also, the EPA is amending the list of source categories established

under section 112(c) of the Act. Natural gas transmission and storage

is being listed as a category of major sources and oil and natural gas

production is being listed as a category of area sources in addition to

its major source listing.

DATES: Comments. Comments must be received on or before April 7, 1998.

For information on submitting electronic comments see the Supplementary

Information section of this document.

Public Hearing. A public hearing will be held, if requested, to

provide interested persons an opportunity for oral presentation of

data, views, or arguments concerning the proposed standards for the oil

and natural gas production and the natural gas transmission and

storage. If anyone contacts the EPA requesting to speak at a public

hearing by March 9, 1998, a public hearing will be held on March 23,

1998, beginning at 9:30 a.m. Persons interested in attending the

hearing should notify Ms. JoLynn Collins, telephone (919) 541-5671,

Waste and Chemical Processes Group (MD-13), to verify that a hearing

will occur.

Request to Speak at a Hearing. Persons wishing to present oral

testimony must contact the EPA by March 9, 1998, by contacting Ms.

JoLynn Collins, Waste and Chemical Processes Group (MD-13), U.S.

Environmental Protection Agency, Research Triangle Park, NC 27711,

telephone (919) 541-5671.

ADDRESSES: Comments. Comments should be submitted (in duplicate, if

possible) to: Air and Radiation Docket and Information Center (MC-

6102), Attention: Docket No. A-94-04, U.S. Environmental Protection

Agency, 401 M Street, SW, Washington, DC 20460. The EPA requests that a

separate copy of comments also be sent to Stephen Shedd, USEPA, Office

of Air Quality Planning and Standards, Research Triangle Park, NC

27711, telephone (919) 541-5397, fax (919) 541-0246 and E-mail:

[email protected]. Comments and data may also be submitted

electronically by following the instructions listed in Supplementary

Information. No confidential business information (CBI) should be

submitted through e-mail.

Background Information Document. The background information

document (BID) may be obtained from the U.S. Environmental Protection

Library (MD-35), Research Triangle Park, NC 27711, telephone (919) 541-

2777. Please refer to ``National Emissions Standards for Hazardous Air

Pollutants for Source Categories: Oil and Natural Gas Production and

Natural Gas Transmission and Storage--Background Information for

Proposed Standards'' (EPA-453/R-94-079a, April 1997) for the BID. This

document may also be obtained electronically from the EPA's Technology

Transfer Network (TTN) (see SUPPLEMENTARY INFORMATION for access

information).

Docket. A docket, No. A-94-04, containing information considered by

the EPA in development of the proposed standards for the oil and

natural gas production and natural gas transmission and storage source

categories, is available for public inspection between 8:00 a.m. and

4:00 p.m., Monday through Friday (except for Federal holidays) at the

following address: U.S. Environmental Protection Agency, Air and

Radiation Docket and Information Center (MC-6102), 401 M Street SW.,

Washington DC 20460, telephone: (202) 260-7548. The docket is located

at the above address in Room M-1500, Waterside Mall (ground floor). The

proposed regulations, BID, and other supporting information are

available for inspection and copying. A reasonable fee may be charged

for copying.

FOR FURTHER INFORMATION CONTACT: For information concerning the

proposed standards, contact Ms. Martha Smith, Waste and Chemical

Processes Group, Emission Standards Division (MD-13), U.S.

Environmental Protection Agency, Research Triangle Park, NC 27711,

(919) 541-2421, or electronically at: [email protected].

SUPPLEMENTARY INFORMATION: Regulated Entities. Regulated categories and

entities include:

------------------------------------------------------------------------

Category Examples of regulated entities

------------------------------------------------------------------------

Industry.......................... Condensate tank batteries, glycol

dehydration units, natural gas

processing plants, and natural gas

transmission and storage

facilities.

------------------------------------------------------------------------

This table is not intended to be exhaustive, but rather provides a

guide for readers regarding entities likely to be regulated by this

action. This table lists the types of entities that the EPA is now

aware could potentially be regulated by this action. Other types of

entities not listed in the table could also be regulated. To determine

whether your facility is regulated by this action, you should carefully

examine the applicability criteria in Secs. 63.760 and 63.1270 of the

rules. If you have questions regarding the applicability of this action

to a particular entity, consult the person listed in the preceding FOR

FURTHER INFORMATION CONTACT section.

Electronic comments can be sent directly to EPA at: A-and-R-

D[email protected]. Electronic comments must be submitted as an

ASCII file avoiding the use of special characters and any form of

encryption. Comments and data will also be accepted on disks in

WordPerfect in 5.1 or 6.1 file format or ASCII file format. All

comments and data in electronic form must be identified by the docket

number A-94-04. Electronic comments on this proposed rule may be filed

online at many Federal Depository Libraries.

This document, the proposed regulatory texts, and BID are available

in Docket No. A-94-04 or by request from the EPA's Air and Radiation

Docket and Information Center (see ADDRESSES) or

[[Page 6289]]

access through the EPA web site at: http://www.epa.gov/ttn/oarpg.

The following outline is provided to aid in reading the preamble to

the proposed oil and natural gas production and natural gas

transmission and storage NESHAPs.

I. Background

A. Purpose of the Proposed Standards

B. Technical Basis for the Proposed Standards

C. Stakeholder and Public Participation

II. Source Category Descriptions

A. Source Category List

B. Hazardous Air Pollutant Types

C. Facility Types

III. Summary of Proposed Standards

A. Proposed Standards for Oil and Natural Gas Production for

Major and Area Sources

B. Proposed Standards for Natural Gas Transmission and Storage

for Major Sources

IV. Summary of Environmental, Energy, and Economic Impacts

A. HAP Emission Reductions

B. Secondary Environmental Impacts

C. Energy Impacts

D. Cost Impacts

E. Economic Impacts

V. Area Source Finding

VI. Glycol Dehydration Unit Nationwide HAP Emissions Estimates

VII. Definition of Major Source for the Oil and Natural Gas Industry

A. Definition of ``Associated Equipment''

B. Definition of Facility

VIII. Rationale for Proposed Standards

A. Selection of Hazardous Air Pollutants for Control

B. Selection of Emission Points

C. Definition of Affected Source

D. Determination of MACT Floor

E. Oil and Natural Gas Production NESHAP-Regulatory Alternatives

for Existing and New Major Sources

F. Oil and Natural Gas Production NESHAP-Regulatory Alternatives

for Existing and New Area Sources

G. Natural Gas Transmission and Storage NESHAP-Regulatory

Alternatives for Existing and New Major Sources

H. Selection of Format

I. Selection of Test Methods and Procedures

J. Selection of Monitoring and Inspection Requirements

K. Selection of Recordkeeping and Reporting Requirements

IX. Relationship to Other Standards and Programs Under the Act

A. Relationship to the Part 70 and Part 71 Permit Programs

B. Relationship Between the Oil and Natural Gas Production and

the Organic Liquids Distribution (Non-Gasoline) Source Categories

C. Relationship of Proposed Standards to the Pollution

Prevention Act

D. Relationship of Proposed Standards to the Natural Gas STAR

Program

E. Overlapping Regulations

X. Solicitation of Comments

A. Potential-to-Emit

B. Definition of Facility

C. Interpretation of ``Associated Equipment'' in Section

112(n)(4) of the Act

D. Regulation of Area Source Glycol Dehydration Units

E. HAP Emission Points

F. Storage Vessels at Natural Gas Transmission and Storage

Facilities

G. Cost Impact and Production Recovery Credits

XI. Administrative Requirements

A. Docket

B. Paperwork Reduction Act

C. Executive Order 12866

D. Regulatory Flexibility

E. Unfunded Mandates

I. Background

A. Purpose of the Proposed Standards

The Act was developed, in part,

* * * to protect and enhance the quality of the Nation's air

resources so as to promote the public health and welfare and

productive capacity of its population [the Act, section 101(b)(1)].

Oil and natural gas production and natural gas transmission and storage

facilities are major and area sources of HAP emissions. The EPA

estimates that approximately 65,000 Mg/yr of HAP are emitted from major

and area sources in the oil and natural gas production source category

and 320 Mg/yr of HAP are emitted from major and area sources in the

natural gas transmission and storage source category. The primary HAP

associated with oil and natural gas that have been identified include

BTEX and n-hexane. Exposure to these chemicals has been demonstrated to

cause adverse health effects. The adverse health effects associated

with the exposure to these specific HAP are discussed briefly in the

following paragraphs. In general, these findings have only been shown

with concentrations higher than those in the ambient air.

Benzene, one of the HAP associated with this NESHAP, has been

classified as a known human carcinogen on the basis of observed

increases in the incidence of leukemia in exposed workers. In addition,

short-term inhalation of high benzene levels may cause nervous system

effects such as drowsiness, dizziness, headaches, and unconsciousness

in humans. At even higher concentrations of benzene, exposure may cause

death, while lower concentrations may irritate the skin, eyes, and

upper respiratory tract. Long-term inhalation exposure to benzene may

cause various disorders of the blood, and toxicity to the immune

system. Reproductive disorders in women, as well as developmental

effects in animals, have also been reported for benzene exposure.

Short-term inhalation of relatively high concentrations of toluene

by humans may cause nervous system effects such as fatigue, sleepiness,

headaches, and nausea, as well as irregular heartbeat. Repeated

exposure to high concentrations may cause additional nervous system

effects, including incoordination, tremors, decreased brain size,

involuntary eye movements, and may impair speech, hearing, and vision.

Long-term exposure of toluene in humans has also been reported to

irritate the skin, eyes, and respiratory tract, and to cause dizziness,

headaches, and difficulty with sleep. Children whose mothers were

exposed to toluene before birth may suffer nervous system dysfunction,

attention deficits, and minor face and limb defects. Inhalation of

toluene by pregnant women may also increase the risk of spontaneous

abortion. Not enough information exists to determine toluene's

carcinogenic potential.

Short-term inhalation of high levels of ethyl benzene in humans may

cause throat and eye irritation, chest constriction, and dizziness.

Long-term inhalation of ethyl benzene by humans may cause blood

disorders. Animal studies have reported blood, liver, and kidney

effects associated with ethyl benzene inhalation. Birth defects have

been reported in animals exposed via inhalation; whether these effects

may occur in humans is not known. Not enough information exists

concerning ethyl benzene for determination of its carcinogenic

potential.

Short-term inhalation of high levels of mixed xylenes (a mixture of

three closely-related compounds) in humans may cause irritation of the

nose and throat, nausea, vomiting, gastric irritation, mild transient

eye irritation, and neurological effects. Long-term inhalation of high

levels of xylene in humans may result in nervous system effects such as

headaches, dizziness, fatigue, tremors, and incoordination. Other

reported effects noted include labored breathing, heart palpitation,

severe chest pain, abnormal heart functioning, and possible effects on

the blood and kidneys. Developmental effects have been reported from

xylene exposure via inhalation in animals. Not enough information

exists to determine the carcinogenic potential of mixed xylenes.

Short-term inhalation of high levels of n-hexane in humans may

cause mild central nervous system effects (dizziness, giddiness, slight

nausea, and headache) and irritation of the skin and mucous membranes.

Long-term inhalation exposure of high levels of n-hexane in humans has

been reported to

[[Page 6290]]

cause nerve damage expressed as numbness in the extremities, muscular

weakness, blurred vision, headache, and fatigue. Reproductive effects

have been reported in animals after inhalation exposure (testicular

damage in rats). Not enough information exists concerning n-hexane for

determination of its carcinogenic potential.

The EPA estimates that the proposed NESHAP would reduce HAP

emissions from those impacted HAP emission points in the oil and

natural gas production source category by 57 percent and would reduce

HAP emissions from triethylene glycol (TEG) dehydration units in the

natural gas transmission and storage source category by 36 percent.

B. Technical Basis for the Proposed Standards

Section 112 of the Act regulates stationary sources of HAP. Section

112(b) of the Act lists 188 chemicals, compounds or groups of chemicals

as HAP. The EPA is directed by section 112 to regulate the emission of

HAP from stationary sources by establishing national emission

standards.

Section 112(a)(1) of the Act defines a major source as:

* * * any stationary source or group of stationary sources located

within a contiguous area and under common control that emits or has

the potential-to-emit considering controls, in the aggregate 10 tons

per year (tpy) or more of any HAP or 25 tpy or more of any

combination of HAP.

An area source is defined as a stationary source that is not a major

source.

For major sources, the statute requires the EPA to establish

standards to reflect the maximum degree of reduction in HAP emissions

through application of maximum achievable control technology (MACT).

Further, the EPA must establish standards that are no less stringent

than the level of control defined under section 112(d)(3) of the Act,

often referred to as the MACT floor. The proposed standards for major

sources in the oil and natural gas production and natural gas

transmission and storage source categories are based on the MACT floor

for these source categories.

In developing standards for area sources of HAP emissions, the EPA

has discretion to establish standards based on (1) MACT, (2) generally

available control technology (GACT), or (3) management practices that

reduce the emission of HAP. The proposed standards for selected area

source TEG dehydration units are based on GACT. There is no statutory

``floor'' level of control for GACT.

Information on industry processes and operations, HAP emission

points, and HAP emission reduction techniques were collected through

section 114 questionnaires that were distributed to companies in the

oil and natural gas production and natural gas transmission and storage

source categories. The companies provided information on representative

facilities.

This information was used, in part, as the technical basis in

determining the MACT level of control for the emission points covered

under the proposed standards. In addition to information collected in

the questionnaires, the EPA considered information available in the

general literature, as well as information submitted by industry on

technical issues subsequent to the questionnaire responses.

C. Stakeholder and Public Participation

Numerous representatives of the oil and natural gas industry and

other interested parties were consulted in the development of the

proposed standards. Industry assisted in data gathering, arranging site

visits, technical review, and sharing of industry-sponsored data

collection activities. A data base comprised of all industry-supplied

information was developed in the evaluation of HAP emissions and air

emission controls for these proposed standards.

Estimates of HAP emissions from representative facilities in each

industry segment were developed by the EPA. To estimate HAP emissions

from glycol dehydration units in both the oil and natural gas

production and natural gas transmission and storage source categories,

the EPA utilized an emission model, GRI-GLYCalc TM (Version

3.0), developed by the Gas Research Institute (GRI). Inputs used by the

EPA for this model were primarily developed from information supplied

by industry.

The trade associations and organizations that participated in the

development of the proposed rules on a regular basis include (1) the

American Petroleum Institute (API) and (2) GRI. Other interested

parties that participated in the development of the proposed standards

include the Independent Petroleum Association of America (IPAA), the

Audubon Society, the Interstate Oil and Gas Compact Commission (IOGCC),

the American Gas Association (AGA), and the Interstate Natural Gas

Association of America (INGAA).

These interested parties, in addition to individual companies in

the oil and natural gas industry, were offered the opportunity to

provide technical review and comment during the development of the

proposed standards. In addition, interested parties provided technical

review and comment on the preliminary draft BID and preliminary draft

standards.

Representatives from other EPA offices and programs were included

in the regulatory development process. These representatives'

responsibilities included review and internal concurrence with the

proposed standards. Therefore, the EPA believes that the impact of

these proposed regulations to other EPA offices and programs has been

adequately considered during the development of these regulations.

This notice also solicits comment on the proposed standards and

offers a chance for a public hearing on the proposals in order to

provide interested persons the opportunity for oral presentation of

data, views, or arguments concerning the proposed standards.

II. Source Category Descriptions

A. Source Category List

Oil and natural gas production was included on the EPA's initial

list of categories of major sources of HAP emissions established under

section 112(c)(1) of the Act. This list was published on July 16, 1992

(57 FR 31576).

The EPA included natural gas transmission and storage in the

proposed initial listing of source categories that was published in

1991. The EPA's preliminary analysis that led to natural gas

transmission and storage being listed as a source category was based on

the estimated emissions of the HAP ethylidene dichloride (1,1-

dichloroethane). Comments received on the proposed initial list

indicated that these estimates were not accurate.

Based on its review of comments for the final initial list, the EPA

decided that it did not have sufficient available information that

supported that this source category could contain a major source of

HAP. Thus, the natural gas transmission and storage source category was

not included as a distinct source category in the final initial list of

source categories of major sources of HAP.

In the development of the proposed standards for the oil and

natural gas production source category, information was obtained on

glycol dehydration unit BTEX emissions that are representative of both

oil and natural gas production facilities and natural gas transmission

and storage facilities. The information obtained indicates that natural

gas transmission and storage facilities have

[[Page 6291]]

the potential to be major HAP sources. In addition, industry has stated

to the EPA that there are major source TEG dehydration units in the

natural gas transmission and storage source category. Therefore, the

EPA is amending the source category list to add the natural gas

transmission and storage source category as a major source category

and, with this notice, is proposing a regulation that would apply to

major sources in this source category.

The EPA has made a determination that there are area sources in the

oil and natural gas production source category that present a threat of

adverse effects to human health and the environment. Based on this

determination, referred to as an ``area source finding,'' the EPA is

amending the source category list to add oil and natural gas production

to the list of area source categories established under section

112(c)(1) of the Act. The area source finding supporting this listing

is discussed in section V of this preamble.

Glycol dehydration units located at natural gas transmission and

storage facilities have similar HAP emissions and emission potential to

those located at oil and natural gas production facilities. The EPA is

currently evaluating whether TEG dehydration units located at natural

gas transmission and storage facilities that are area sources

constitute an unacceptable risk to public health or the environment and

should be listed and regulated as an area source. The EPA is soliciting

information and comment in this notice regarding the location and HAP

emissions from area source TEG dehydration units in the natural gas

transmission and storage source category (see sections V and X for

further discussion).

The documentation supporting the listing of oil and natural gas

production as a source category (``Documentation for Developing the

Initial Source Category List,'' EPA-450/3-91-030, July 1992) describes

the source category as including

* * * the processing and upgrading of crude oil prior to entering

the petroleum refining process and natural gas prior to entering the

transmission line.

During the development of the proposed rules, industry requested that

HAP emissions associated with distribution of hydrocarbon liquids after

the point of custody transfer be addressed within the scope of the

organic liquids distribution (non-gasoline) source category and not the

oil and natural gas production source category. Custody transfer, as

defined in a previous rule, means transfer, after processing and/or

treatment in the producing operations, from storage vessels or

automatic transfer facilities to pipelines or any other forms of

transportation. Industry representatives commented that there are

differences in the HAP emission potential from facilities involved in

the distribution of petroleum liquids after the point of custody

transfer relative to other processes and operations in the oil and

natural gas production source category.

The EPA, after evaluation of industry comments, is proposing that

HAP emissions associated with the distribution of hydrocarbon liquids

after the point of custody transfer would be more appropriately

addressed as part of the organic liquids distribution (non-gasoline)

source category. Therefore, the proposed rule for the oil and natural

gas production source category would not apply to those facilities that

distribute hydrocarbon liquids after the point of custody transfer (see

proposed regulation for definition of custody transfer).

Facilities involved in the organic liquids distribution (non-

gasoline) sector of the petroleum industry include (but are not limited

to) gathering stations, trunk-line stations, and station storage vessel

farms. The organic liquids distribution (non-gasoline) source category

is scheduled for regulation under section 112 of the Act by November

15, 2000.

The EPA plans to define the organic liquids distribution (non-

gasoline) source category (within that rulemaking) as including those

facilities that distribute hydrocarbon liquids after the point of

custody transfer. This will eliminate the potential for overlapping

regulatory requirements between the oil and natural gas production and

organic liquids distribution (non-gasoline) source categories.

B. Hazardous Air Pollutant Types

The primary HAP associated with the oil and natural gas production

and natural gas transmission and storage source categories include BTEX

and n-hexane. In addition, available information indicates that 2,2,4-

trimethylpentane (iso-octane), formaldehyde, acetaldehyde, naphthalene,

and ethylene glycol may be present in certain process and emission

streams. Carbon disulfide (CS2), carbonyl sulfide (COS), and

BTEX may also be present in the tail gas streams from amine treating

and sulfur recovery units.

C. Facility Types

The oil and natural gas production and natural gas transmission and

storage source categories consist of various facilities used to recover

and treat products (hydrocarbon liquids and gases) from production

wells. These source categories include the processing, storage, and

transport of these products to (1) the point of custody transfer for

the oil and natural gas production source category or (2) the point of

delivery to the local distribution company (LDC) or final end user for

the natural gas transmission and storage source category. The

facilities in the oil and natural gas production source category that

the EPA is proposing requirements for include (1) glycol dehydration

units, (2) condensate tank batteries, and (3) natural gas processing

plants. The EPA is also proposing requirements for glycol dehydration

units located at facilities in the natural gas transmission and storage

source category.

1. Glycol Dehydration Units

The most widely used dehydration process in these source categories

is glycol dehydration. TEG dehydration units account for the majority

of glycol dehydration units, with ethylene glycol (EG) and diethylene

glycol (DEG) dehydration units accounting for the remaining population

of glycol dehydration units. In the dehydration process, natural gas is

contacted with glycol to remove water present in the natural gas. Some

portion of the HAP present in the natural gas are also removed by the

glycol. The ``rich'' glycol is then heated in a reboiler to remove

water vapor and other contaminants prior to recirculation in the

process. The reboiler vent of the glycol dehydration unit is the

primary identified source of HAP emissions for these source categories.

2. Tank Batteries

The term ``tank battery'' refers to the collection of process

equipment used to separate, upgrade, store, and transfer extracted

petroleum products and separated streams. These facilities handle crude

oil and condensate up to the custody transfer of these products to

facilities in the organic liquids distribution (non-gasoline) source

category. Separation and dehydration of natural gas can also occur at a

tank battery. A tank battery may serve an individual production well or

a collection of wells in the field.

Tank batteries can be broadly classified as black oil tank

batteries or condensate tank batteries. Black oil means hydrocarbon

(petroleum) liquid with a gas-to-oil ratio (GOR) less than 50 cubic

meters (m3) (1,750 cubic feet (ft3)) per barrel

and an API gravity less than

[[Page 6292]]

40 degrees ( deg.). Condensate means hydrocarbon liquid that condenses

because of changes in temperature, pressure, or both, and remains

liquid at standard conditions. The majority of tank batteries,

approximately 85 percent, are black oil tank batteries and the

remainder are condensate tank batteries.

The primary identified HAP emission points at tank batteries

include (1) process vents associated with glycol dehydration units and

(2) tanks and vessels storing volatile oils, condensate, and other

similar hydrocarbon liquids that have a flash emission potential.

Condensate tank batteries typically incorporate a glycol dehydration

unit in the process system.

The EPA proposes to exempt from the oil and natural gas production

NESHAP those facilities that handle black oil exclusively. This

exemption is based on the EPA's proposed interpretation of associated

equipment in section 112(n)(4) of the Act. The EPA is proposing that

associated equipment be defined as all equipment associated with a

production well up to the point of custody transfer, except that glycol

dehydration units and storage vessels with flash emissions would not be

associated equipment. The EPA believes that this proposed definition

will provide the relief that Congress intended in section 112(n)(4) for

the numerous, widely dispersed, small emission points in the oil and

natural gas production source category (such as black oil tank

batteries) while preserving the EPA's ability to require appropriate

MACT or GACT controls for the most significant identified HAP emission

points in this source category (see section VII of this preamble for a

detailed discussion of associated equipment).

3. Natural Gas Processing Plants

A natural gas processing plant conditions natural gas by separating

natural gas liquids (NGLs) from field natural gas and, in addition, may

fractionate the NGLs into separate components such as ethane, propane,

butane, and natural gasoline. Natural gas processing may also include

amine treating and sulfur recovery units onsite to treat natural gas

streams.

The primary identified HAP emission points at natural gas

processing plants include (1) the glycol dehydration unit reboiler

vent, (2) storage tanks, particularly those tanks that handle volatile

oils and condensates that may be significant contributors to overall

HAP emissions due to flash emissions, and (3) equipment leaks from

those components handling hydrocarbon streams that contain HAP

constituents. Other potential HAP emission point process vents are the

tail gas stream from amine treating processes and sulfur recovery

units. Limited information has been identified on the potential for HAP

emissions from these operations. Recent research published by GRI

indicates that these emission points have the potential to be

significant sources of HAP emissions. Comment is requested on potential

HAP emissions and emission rates from these operations and potential

applicable air emission controls.

4. Natural Gas Transmission and Storage Facilities

The natural gas transmission and storage source category consists

of transmission pipelines used for the long distance transport of

natural gas and underground natural gas storage facilities. These

facilities typically extend from the natural gas processing plant to

the local distribution company that delivers natural gas to the final

end user. In cases where there is no processing, these facilities may

be located anywhere from the well to the final end user.

Specific equipment used in natural gas transmission includes the

land, mains, valves, meters, boosters, regulators, storage vessels,

dehydrators, compressors, and their driving units and appurtenances,

and equipment used for transporting gas from a production plant,

delivery point of purchased gas, gathering system, storage area, or

other wholesale source of gas to one or more distribution area(s).

Underground natural gas storage facilities are subsurface

facilities that store natural gas that has been transferred from its

original location for the primary purpose of load balancing. Load

balancing is the process of equalizing the receipt and delivery of

natural gas (i.e., utilized for stockpiling natural gas for periods of

high demand, in particular, the winter heating season). Processes and

operations that may be located at an underground storage facility

include, but are not limited to, compression and dehydration.

The primary identified HAP emission point at natural gas

transmission and storage facilities is the glycol dehydration unit

reboiler vent.

5. Facility Populations

There are a large number of glycol dehydration units and tank

batteries in the United States. The estimated population of glycol

dehydration units presented in various industry studies range from

under 20,000 to over 45,000 glycol dehydration units.

For the purpose of estimating nationwide impacts of this proposed

NESHAP, the EPA selected 40,000 as the estimated total domestic

population of all types of dehydration units. Of this total, an

estimated 38,000 are glycol dehydration units and 2,000 are solid

desiccant dehydration units.

Based on typical tank battery configurations and two studies

conducted for the API, the EPA estimates that there are approximately

94,000 tank batteries. Of this total, the EPA estimates that there are

81,000 black oil tank batteries and 13,000 condensate tank batteries.

In 1996, according to the Oil and Gas Journal, there were

approximately 700 natural gas processing plants.

The natural gas transmission and storage source category includes

over 480,000 kilometers (300,000 miles) of high-pressure transmission

pipelines and over 300 underground storage facilities. A recent GRI

report estimates that there are 1,900 compressor stations located along

transmission pipelines.

The EPA estimates that approximately 440 existing facilities would

be affected by the proposed requirements of the production NESHAP for

major sources. In addition, the EPA estimates that out of an estimated

37,000 glycol dehydration units at area sources of HAP, 520 existing

TEG dehydration units would be affected by the proposed standards for

area sources because they meet or exceed the throughput and benzene

emission action levels and are also located in counties designated as

urban (see section III of this preamble for a discussion of area source

action levels).

The EPA estimates that about 5 existing facilities would be

affected by the proposed requirements of the natural gas transmission

and storage NESHAP for major sources.

III. Summary of Proposed Standards

A. Proposed Standards for Oil and Natural Gas Production for Major and

Area Sources

The proposed action would amend title 40, chapter I, part 63 of the

Code of Federal Regulations (CFR) by adding a new subpart HH--National

Emission Standards for Hazardous Air Pollutants from Oil and Natural

Gas Production Facilities. The proposed standards would apply to owners

and operators of facilities that process, upgrade, or store (1)

hydrocarbon liquids (with the exception of those facilities that handle

black oil exclusively) to the point of custody transfer and (2) natural

gas from the well up to and including the natural gas processing plant.

Standards are

[[Page 6293]]

proposed that would limit HAP emissions from the following emission

points at facilities that are major sources of HAP (1) process vents on

glycol dehydration units, (2) storage vessels with flash emissions, and

(3) equipment leaks at natural gas processing plants. In addition,

standards are proposed that would limit HAP emissions from selected

area source TEG dehydration units.

As required by the Clean Air Act, the determination of a facility's

potential-to-emit HAP and, therefore, its status as a major or area

source, is based on the total of all HAP emissions from all activities

at a facility, except that emissions from oil or gas exploration or

production wells (and their associated equipment) and emissions from

pipeline compressor or pump stations may not be combined. A definition

of associated equipment is proposed in the proposed rulemaking. Further

discussion of the definition of associated equipment is presented in

section VII(A) of this preamble.

1. General Standards

The proposed standards for oil and natural gas production

facilities would require that the owner or operator of a major source

of HAP reduce HAP emissions from glycol dehydration units and storage

vessels through the application of air emission control equipment or

pollution prevention measures. In addition, the owner or operator of a

natural gas processing plant that is a major source would be required

to reduce HAP emissions from equipment leaks by establishing a leak

detection and repair (LDAR) program.

The owner or operator of selected area source TEG dehydration units

that meet the criteria in the proposed standards would be required to

reduce HAP emissions from those TEG dehydration units.

Owners and operators of facilities that process and store black oil

exclusively would not be subject to the proposed standards. Black oil

is defined in the proposed oil and natural gas production NESHAP as a

hydrocarbon liquid with (1) a GOR less than 50 m\3\ (1,750 ft\3\) per

barrel and (2) an API gravity less than 40 deg..

2. Glycol Dehydration Unit Provisions

The proposed standards would require that all process vents at

glycol dehydration units that are located at major HAP sources be

controlled unless (1) the actual flowrate of natural gas to the glycol

dehydration unit is less than 85 thousand cubic meters per day (m\3\/

day) (3.0 million standard cubic feet per day (MMSCF/D), on an annual

average basis, or (2) if benzene emissions from the major source glycol

dehydration unit are less than 0.9 Mg/yr (1 tpy).

HAP emissions from process vents at certain area source TEG

dehydration units would be required to be controlled unless (1) the

actual flowrate of natural gas to the glycol dehydration unit is less

than 85 thousand m\3\/day (3.0 MMSCF/D), on an annual average basis, or

(2) if benzene emissions from the area source glycol dehydration unit

are less than 0.9 Mg/yr (1 tpy). The proposed requirements are the same

for existing and new (1) major source glycol dehydration units and (2)

selected area source TEG dehydration units that meet the specified

criteria.

In its analysis of available data, the EPA could not determine any

level of emission control for those glycol dehydration units with low

annual natural gas throughputs (less than 85 thousand m\3\/day (3.0

MMSCF/D), on an annual average basis, or a low benzene emission rate

(less than 0.9 Mg/yr (1 tpy)). Thus, the EPA is proposing the annual

throughput and benzene emission rate cutoffs for major sources. In

addition, the EPA's analysis indicated that control of HAP emissions

below these cutoff levels was not cost-effective for area source glycol

dehydration units.

The EPA is proposing an additional applicability criteria for area

source TEG dehydration units. The additional proposed criteria would

limit air emission controls to those selected area source TEG

dehydration units located in counties classified as urban areas.

Since the Act does not provide a definition of urban area, the EPA

used the U.S. Department of Commerce's Bureau of the Census statistical

data to classify every county in the U.S. into one of three

classifications (1) Urban-1 counties, (2) Urban-2 counties, or (3)

Rural counties. Urban-1 counties consist of counties with metropolitan

statistical areas (MSA) with a population greater than 250,000. Urban-2

counties are defined as all other counties designated urban by the

Bureau of Census (areas which comprise one or more central places and

the adjacent densely settled surrounding fringe that together have a

minimum of 50,000 persons). The urban fringe consists of contiguous

territory having a density of at least 1,000 persons per square mile.

Rural counties are those counties not designated as urban by the Bureau

of the Census (see docket item A-94-04, II-I-9).

Figure 1 shows the methodology for assigning counties to each of

the three classifications. As seen in this diagram, if any part of a

county contains an Urban-1 area then the entire county is classified as

an Urban-1 area. For all remaining counties, if greater than 50 percent

of the population is classified as urban, then that county is

classified as an Urban-2 area. Counties not designated as Urban-1 or

Urban-2 by the above method are classified as Rural areas.

BILLING CODE 6560-50-P

[[Page 6294]]

[GRAPHIC] [TIFF OMITTED] TP06FE98.005

BILLING CODE 6560-50-C

Figure 1. Urban/Rural County Classification Methodology

[[Page 6295]]

Thus, only those area source TEG dehydration units that (1) meet or

exceed the actual natural gas throughput applicability criteria, (2)

meet or exceed the benzene emission rate applicability criteria, and

(3) are located in a county classified as either Urban-1 or Urban-2

would be required to apply air emission controls on all process vents

at those units.

The EPA also evaluated a risk-based distance applicability

threshold criterion as an alternative to the urban area applicability

criteria. This method (subsequently referred to as the ``risk-

distance'' method) would target those area source TEG dehydration units

for regulation that present a potential health risk to exposed

populations. Under the risk-distance method, each area source TEG

dehydration unit that may be subject to control, based on actual

natural gas throughput and benzene emission rate, would have the option

of conducting a site-specific risk assessment. If this site-specific

risk assessment resulted in a maximum incremental lifetime cancer risk

above some threshold level, then the source would be required to

install controls necessary to reduce that risk to an acceptable level.

After its evaluation of applicability alternatives, the EPA

rejected the risk-distance method. The risk based approach would focus

solely on the protection of the most exposed individual rather than the

general population. In addition, the EPA believes that the use of the

urban area as an applicability criteria provides ease of

implementation. This approach (1) limits the group of affected sources

to a well defined urban area group, (2) minimizes the non-productive

burden by exempting the non-urban area group of owners-operators and

regulatory agencies from compliance assessments, and (3) provides a

straightforward approach to compliance. Area sources will not need to

perform analyses to determine if they are affected by the rule if they

screen out based on the urban area criteria. Only those owner-operators

of area source TEG dehydration units in urban areas would need to

evaluate the need for control devices. By contrast, under the risk

distance approach, all owner-operators would need to do an analysis.

The EPA is requesting comment, along with supporting documentation, on

the use of a risk-distance criteria for regulation of area source TEG

dehydration units as an alternative to the urban area criteria (see

section X of this preamble).

Glycol dehydration units that are required to use air emission

controls would be required to connect each process vent on the glycol

dehydration unit to an air emission control system that reduces HAP

emissions by 95 percent or greater (or to an outlet concentration of 20

parts per million by volume (ppmv) for combustion devices). Pollution

prevention measures, such as process modifications that reduce the

amount of HAP emissions generated, would be allowed as an alternative,

provided they achieve a HAP emission reduction, from uncontrolled

levels, of 95 percent or greater.

3. Storage Vessel Provisions

Standards are proposed for existing and new storage vessels

containing hydrocarbon liquids (other than black oil) that are located

at major HAP sources. The types of storage vessels that would be

regulated are those with the potential for flash emissions and that

have an actual throughput of hydrocarbon liquids equal to or greater

than 500 barrels per day (BPD).

Flash emissions from storage occur when a hydrocarbon liquid with a

high vapor pressure flows from a pressurized vessel into a vessel with

a lower pressure. Flash emissions typically occur when a hydrocarbon

liquid, such as condensate, is transferred from a production separator

to a storage vessel. The proposed standards for storage vessels with

the potential for flash emissions would require that a storage vessel

be equipped with an air emission control system if the hydrocarbon

liquid in the storage vessel has a GOR equal to or greater than 50 m

\3\ (1,750 ft \3\) per barrel or an API gravity equal to or greater

than 40 deg. (i.e., the storage vessel has a potential for flash

emission losses). In addition, the storage vessel must have an actual

throughput of hydrocarbon liquids equal to or greater than 500 BPD.

A storage vessel containing a hydrocarbon liquid subject to control

under the proposed standards would have to be equipped with a cover

vented through a closed-vent system to a control device that recovers

or destroys HAP emissions with an efficiency of 95 percent or greater

(or to an outlet concentration of 20 ppmv for combustion devices). The

EPA has included the 20 ppmv cutoff for cases where the HAP emission

concentration is already low, and meeting a 95 percent reduction in

emissions cannot be achieved.

A pressurized storage vessel that is designed to operate as a

closed system would be considered in compliance with the proposed

requirements for storage vessels. External and internal floating roofs

that meet certain design criteria would also be allowed.

4. Standards for Equipment Leaks

The proposed rule requires owners and operators of natural gas

processing plants that are major HAP sources to control HAP emissions

from leaks from each piece of equipment that contains or contacts a

liquid or gas that has a total HAP concentration equal to or greater

than 10 percent by weight. The proposed equipment leak standards would

not apply to equipment that operates less than 300 hours per year.

For equipment subject to these standards at either an existing or

new source, the owner or operator is required to implement a LDAR

program and perform equipment modifications, where necessary. Pumps in

light liquid service, valves in gas/vapor and light liquid service, and

pressure relief devices in gas/vapor service within a process unit that

is located on the Alaskan North Slope would be exempt from some of the

routine LDAR monitoring requirements.

5. Air Emission Control Equipment Requirements

Specific performance and operating requirements are proposed for

each control device installed by the owner or operator. Closed-vent

systems would be required to operate with no detectable emissions. Any

type of control device would be allowed that reduces the mass content

of either total organic compounds (less methane and ethane) or total

HAP in the gases vented to the device by 95 percent by weight or

greater (or to an outlet concentration of 20 ppmv for combustion

devices).

Certain specifications for covers apply based on the type of cover

and where the cover is installed. Requirements are specified for vapor

leak-tight covers, and external and internal floating roofs installed

on storage vessels.

6. Test Methods and Procedures

An owner or operator must be able to demonstrate that exemption

from control criteria are met when controls are not applied. For

example, owners or operators of glycol dehydration units that do not

install air emission controls because the benzene emission rate from

the unit is less than 0.9 Mg/yr (1 tpy) must be able to demonstrate

that the benzene emission rate from the unit is less than 0.9 Mg/yr (1

tpy). In general, the selected exemption criteria minimize the

demonstration burden on owners and operators.

Procedures for demonstrating the HAP emission reduction efficiency

of control devices and HAP concentration would be consistent with

procedures established in previously promulgated

[[Page 6296]]

NESHAP that apply to emission sources similar to those addressed in the

proposed standards. Engineering calculations, modeling (using EPA-

approved models), and previous test results will generally be

acceptable means of demonstrating compliance, except where such means

are not conclusive. Test procedures are specified in the proposed rule

for use when testing is required to demonstrate compliance.

An alternative test procedure is provided to demonstrate control

efficiency for when a condenser is used for controlling emissions from

a glycol dehydration unit reboiler vent. The inclusion of the

alternative test procedure is appropriate in this standard because of

difficulties associated with testing the inlet to a condenser in this

application.

Procedures and test methods are also specified for detection of

equipment leaks.

7. Monitoring and Inspection Requirements

The proposed standards would require that the owner or operator

periodically inspect and monitor air emission control equipment. Visual

inspections and leak detection monitoring is required for certain types

of covers to ensure gaskets and seals are in good condition and for

closed-vent systems to ensure all fittings remain leak-tight.

An owner or operator would also be required to visually inspect and

test covers and closed-vent systems to determine and ensure that they

operate with no detectable emissions.

The proposed standards would also require semi-annual inspection

and leak detection monitoring of covers and annual inspection and leak

detection monitoring of closed-vent systems.

The proposed standards would require continuous monitoring of

control device operation through the use of automated instrumentation.

The automated instrumentation would be used to measure and record

control device operating parameters indicating continuous compliance

with the standards.

8. Recordkeeping and Reporting Requirements

The recordkeeping and reporting requirements associated with the

proposed standards would primarily be those specified in the part 63

General Provisions (40 CFR part 63, subpart A). Major sources would be

subject to all of the requirements of the General Provisions with the

exception that (1) owners or operators would be allowed up to one year

from the effective date of the standards to submit the initial

notification described in Sec. 63.9, paragraph (b) of subpart A and (2)

owners or operators are allowed to submit (a) excess emissions and

continuous monitoring system (CMS) performance reports and (b) startup,

shutdown, and malfunction reports semi-annually instead of quarterly.

The EPA selected these specific exceptions due to the large number of

facilities that would need to submit notifications or reports related

to the proposed NESHAP. The EPA believes that these exceptions will not

adversely affect the implementation of the proposed regulation or

reduce its impact on HAP emissions.

Area sources would be subject to all of the requirements of the

General Provisions with the exception that (1) owners or operators of

existing area sources would be allowed up to one year from the

effective date of the standards to submit the initial notification

required by the General Provisions, (2) an owner or operator of an area

source would not be required to develop and maintain a startup,

shutdown, and malfunction plan and would only need to submit reports of

malfunctions when they are not corrected within a specified time

period, and (3) excess emissions and continuous monitoring reporting

would be done annually, rather than as required by the General

Provisions.

B. Proposed Standards for Natural Gas Transmission and Storage for

Major Sources

The proposed standards would amend title 40, chapter I, part 63 CFR

by adding a new subpart HHH--National Emission Standards for Hazardous

Air Pollutants from Natural Gas Transmission and Storage Facilities.

The standards would apply to owners and operators of facilities that

process, upgrade, transport or store natural gas prior to delivery to a

LDC or a final end user.

1. General Standards

The proposed rule would require that process vents on glycol

dehydration units that are located at major HAP sources be controlled

unless (1) the actual flowrate of natural gas to the glycol dehydration

unit is less than 85 thousand m3/day (3.0 MMSCF/D), on an

annual average basis, or (2) if benzene emissions from the major source

glycol dehydration unit are less than 0.9 Mg/yr (1 tpy). The proposed

requirements are the same for existing and new glycol dehydration

units.

Glycol dehydration units that are required to use air emission

controls would be required to connect each process vent on the glycol

dehydration unit to an air emission control system that reduces HAP

emissions by 95 percent or more or to an outlet concentration of 20

ppmv for combustion devices. As with the proposed standards for the oil

and natural gas production NESHAP, pollution prevention measures, such

as process modifications that reduce the amount of HAP emissions

generated, would be allowed as an alternative provided they achieve a

HAP emission reduction of 95 percent or greater or to an outlet

concentration of 20 ppmv for combustion devices.

The EPA had insufficient information available to determine whether

(1) significant HAP-emitting storage vessels warranting control are

located at natural gas transmission and storage facilities or (2)

whether the same storage vessel regulatory controls being proposed for

the oil and natural gas production source category should be applied to

the natural gas transmission and storage source category. Therefore,

the EPA is soliciting comment in this proposal (see section X) on

whether the storage vessels being proposed for control under the oil

and natural gas production regulation are similar to those that exist

at natural gas transmission and storage facilities. The EPA is

specifically requesting information on (1) the type(s) of storage

vessels at natural gas transmission and storage facilities and (2)

whether the existing control level of storage vessels at natural gas

transmission and storage facilities is similar to the existing control

level of storage vessels at oil and natural gas production facilities.

2. Air Emission Control Equipment Requirements

Specific performance and operating requirements are proposed for

each control device installed by the owner or operator. Closed-vent

systems would be required to operate with no detectable emissions. Any

type of control device would be allowed that reduces the mass content

of either total organic compounds (less methane and ethane) or total

HAP in the gases vented to the device by 95 percent by weight or

greater (or to an outlet concentration of 20 ppmv for combustion

devices).

3. Monitoring and Inspection Requirements

The proposed monitoring and inspection requirements are (1)

periodic control equipment monitoring, (2) periodic leak detection

monitoring for closed-vent systems to ensure all fittings remain leak-

tight, (3) semi-annual

[[Page 6297]]

inspection and leak detection monitoring of covers, (4) annual

inspection and leak detection monitoring of closed-vent systems, and

(5) continuous monitoring of control device operation. Continuous

monitoring would require the use of automated instrumentation that

would measure and record control device compliance operating

parameters.

4. Recordkeeping and Reporting Requirements

The recordkeeping and reporting requirements associated with the

proposed standards would primarily be those specified in the part 63

General Provisions (40 CFR Part 63 subpart A). Major sources would be

subject to all of the requirements of the General Provisions, except

that (1) owners or operators would be allowed up to one year from the

effective date of the standards to submit the initial notification

required under Sec. 63.9, paragraph (b) of subpart A and (2) owners or

operators are allowed to submit excess emissions, CMS performance

reports, and startup, shutdown, and malfunction reports semi-annually

instead of quarterly. These exceptions were selected to maintain

consistency between the major source provisions of these proposed

regulations.

IV. Summary of Environmental, Energy and Economic Impacts

A. HAP Emission Reductions

For major sources, it is estimated by the EPA that the proposed oil

and natural gas production standards for existing sources would result

in a reduction of HAP emissions from 39,000 Mg/yr to 9,000 Mg/yr. In

addition, HAP emissions would be reduced by 3,000 Mg/yr for new sources

over the first 3 years after promulgation of these proposed standards.

For existing area source TEG dehydration units in the oil and

natural gas production source category, the EPA estimates that the

proposed standards would result in a reduction of HAP emissions from

19,000 Mg/yr to 16,000 Mg/yr. In addition, HAP emissions would be

reduced by 330 Mg/yr for new sources over the first 3 years after

promulgation of these proposed standards.

Tables 1 and 2 present the major and area source emission

reductions, in addition to other environmental, energy, and cost

impacts, that the EPA estimates would occur from the implementation of

the proposed standards for oil and natural gas production.

The EPA estimates that the proposed natural gas transmission and

storage standards for existing sources would result in a reduction of

HAP emissions from 320 Mg/yr to 210 Mg/yr. No new major sources are

anticipated in the first three years after promulgation of this

proposed NESHAP. Table 3 presents the major source emission reductions,

in addition to other environmental, energy, and cost impacts, that the

EPA estimates would occur from the implementation of the proposed

standards for existing natural gas transmission and storage facilities.

The air emission reductions achieved by these proposed standards,

when combined with the air emission reductions achieved by other

standards mandated by the Act, will accomplish the primary goal of the

Act to

* * * enhance the quality of the Nation's air resources so as to

promote the public health and welfare and the productive capacity of

its population.

Table 1.--Summary of Estimated Environmental, Energy, and Economic

Impacts for the Proposed Oil and Natural Gas Production Standards for

Existing and New Major Sources

------------------------------------------------------------------------

Impact category Existing New

------------------------------------------------------------------------

Estimated number of impacted facilities....... 440 44

Emission reductions (Mg/yr):

HAP....................................... 30,000 3,000

VOC....................................... 61,000 6,100

Methane................................... 7,000 700

Secondary environmental emission increases (Mg/

yr):

Sulfur oxides............................. a

------------------------------------------------------------------------

Impact category Existing

------------------------------------------------------------------------

Estimated number of impacted facilities.................... 5

Emission reductions (Mg/yr):

HAP.................................................... 110

VOC.................................................... 1,400

Methane................................................ 54

Secondary environmental emission increases (Mg/yr):

Sulfur oxides.......................................... None

Nitrogen oxides........................................ None

Carbon monoxide........................................ None

Energy (Kilowatt hours per year)........................... None

Implementation costs (Thousand of July 1993 $):

Total installed capital................................ 57

Total annual........................................... 46

------------------------------------------------------------------------

a No new major sources are anticipated for this source category after

the effective date for new sources and in the first three years

following promulgation of the proposed rule.

B. Secondary Environmental Impacts

Other environmental impacts are those associated with operation of

certain air emission control devices. The adverse secondary air impacts

would be minimal in comparison to the primary HAP reduction benefits

from the implementation of the proposed control options for major and

for selected area oil and natural gas sources. The estimated national

annual increase in secondary air pollutant emissions that would result

from the use of a flare to comply with the proposed standards is

estimated to be less than 1.0 Mg (1.1 ton) for both sulfur oxide

(SOX) and carbon monoxide (CO) and less than 7 Mg (8 tons)

for nitrogen oxides (NOX). These estimates are for both

major and area oil and natural gas production sources. There are no

anticipated increases in secondary air pollutant emissions from the

implementation of the proposed control options for major sources at

natural gas transmission and storage facilities.

The adverse water impacts anticipated from the implementation of

control options for the proposed standards are expected to be minimal.

The water impacts associated with the installation of a condenser

system for the glycol dehydration unit reboiler vent would be minimal.

This is because the condensed water collected with the hydrocarbon

condensate can be directed back into the system for reprocessing with

the hydrocarbon condensate or, if separated, combined with produced

water for disposal by reinjection.

Similarly, the water impacts associated with installation of a

vapor control system would be minimal. This is because the water vapor

collected along with hydrocarbon vapors in the vapor collection and

redirect system can be directed back into the system for reprocessing

with the hydrocarbon condensate or, if separated, combined with the

produced water for disposal by reinjection.

There are no adverse solid waste impacts anticipated from the

implementation of the proposed standards.

C. Energy Impacts

Energy impacts are those energy requirements associated with the

operation of emission control devices. The annual energy requirements

for each vapor collection/recovery system installed to comply with the

oil and natural gas production proposed standards is estimated to be

300 kilowatt hours per year (kw-hr/yr). It is estimated that

approximately 125 oil and natural gas production major source

facilities would install one or more of these control options. There

would be no national energy demand increase from the operation of any

of the control options analyzed under the proposed oil and natural gas

production standards for area sources and the national energy demand

increase for major sources would be an estimated 38,000 kw-hr/yr.

There would be no national energy demand increase from the

operation of any of the control options analyzed under the proposed

natural gas transmission and storage standards for major sources.

The proposed standards encourage the use of emission controls that

recover hydrocarbon products, such as methane and condensate, that can

be used on-site as fuel or reprocessed, within the production process,

for sale. Thus, the proposed standards have a positive impact

associated with the recovery of non-renewable energy resources.

D. Cost Impacts

The estimated total capital cost to comply with the proposed rule

for major sources in the oil and natural gas production source category

is approximately $6.5 million. The total capital cost for area sources

is estimated to be approximately $6.9 million.

The total estimated net annual cost to industry to comply with the

proposed requirements for major sources in the oil and natural gas

production source category is approximately $4.0 million. The total net

annual cost for area source TEG dehydration units is approximately $6.2

million. These estimated annual costs include (1) the cost of capital,

(2) operating and maintenance costs, (3) the cost of monitoring,

inspection, recordkeeping, and reporting (MIRR), and (4) any associated

product recovery credits.

The estimated total capital cost to comply with the proposed rule

for major sources in the natural gas transmission and storage source

category is approximately $57,000.

The total estimated net annual cost to industry to comply with the

proposed requirements for major sources in the natural gas transmission

and storage source category is approximately $46,000. As with the oil

and natural gas production total estimated annual cost to industry,

this annual cost estimate includes (1) the cost of capital, (2)

operating and maintenance costs, (3) the cost of MIRR, and (4) any

associated product recovery credits.

The EPA's impact analyses consider a facility's ability to handle

collected vapors. Some remotely located facilities may not be able to

use collected vapor for fuel or recycle it back into the process. In

addition, it may not be technically feasible for some facilities to

[[Page 6299]]

utilize the non-condensable vapor streams from condenser systems as an

alternative fuel source safely. An option for these facilities is to

combust these vapors by flaring.

These concerns are reflected in the analyses conducted by the EPA.

In its analyses, the EPA estimated that (1) 45 percent of all impacted

facilities will be able to use collected vapors from installed control

options as an alternative fuel source for an on-site combustion device

such as a process heater or the glycol dehydration unit firebox, (2) 45

percent will be able to recycle collected vapors from installed control

options into a low pressure header system for combination with other

hydrocarbon streams handled at the facility, and (3) 10 percent will

direct all collected vapor to an on-site flare.

E. Economic Impacts

The EPA prepared an economic impact analysis that evaluates the

impacts of the regulation on affected producers, consumers, and

society. The economic analysis focuses on the regulatory effects on the

U.S. natural gas market that is modeled as a national, perfectly

competitive market for a homogenous commodity. The analysis does not

include a model to assess the regulatory effects on the world crude oil

market because the regulation is anticipated to affect less than 5

percent of the total U.S. crude oil production, and thus, it is

unlikely to have any influence on the U.S. supply of crude oil or world

crude oil prices.

The imposition of regulatory costs on the natural gas market result

in negligible changes in natural gas prices, output, employment,

foreign trade, and business closures. Price and output changes as a

result of the regulation are less than 0.01 of one percent, which is

significantly less than observed market trends. For example, between

1992 and 1993 the average change in wellhead price increased by 14

percent, while domestic production rose by 3 percent.

The total annual social cost of the regulation is $10 million for

major and areas sources combined. This value accounts for the

compliance cost imposed on producers, as well as market adjustments

that influence the revenues to producers and consumption by end users,

plus the associated deadweight loss to society of the reallocation of

resources.

V. Area Source Finding

The EPA performed an analysis to determine the potential threat of

adverse effects on human health and the environment due to HAP

emissions from TEG dehydration units in the oil and natural gas

production source category and the feasibility and impacts of

controlling these emissions. The EPA refers to this determination as an

``area source finding.'' The three primary components of an area source

finding are (1) a risk assessment conducted for area source TEG

dehydration units, (2) an evaluation of the technical feasibility and

associated costs of air emission controls, and (3) an assessment of the

economic impacts associated with installation of controls.

The EPA conducted a risk assessment for area source TEG dehydration

units. The detailed risk assessment is available for review in EPA Air

Docket A-94-04 and the item entry number is II-B-20.

The HAP included in the risk assessment were BTEX and n-hexane.

These are the primary HAP emitted by TEG dehydration units. Toluene,

ethyl benzene, and n-hexane were evaluated for potential non-cancer

impacts. The predicted human exposure levels associated with the

estimated emission of these HAP from area source TEG dehydration units

did not meet or exceed the levels of concern when compared to the

available human health reference levels. Mixed xylenes were not

quantitatively analyzed since the EPA does not have an appropriate

human health benchmark for assessing human xylene exposure by the

inhalation pathway.

The predicted exposures associated with the estimated emission of

benzene from area source triethylene glycol dehydration units result in

a maximum individual risk (MIR) of 3 x 10-4 and an annual

cancer incidence ranging from -6 to

1 x 10-4.

The types of controls used on TEG dehydration units are able to

achieve a minimum of 95 percent HAP emission reduction. In the parts of

the U.S. where the vast majority of natural gas is produced and

processed, condensers are typically used to reduce emissions from TEG

dehydration units. Flares are also used to reduce emissions from TEG

dehydration units.

Unlike flares, which destroy emissions through combustion,

condensers capture emissions and allow for the recovery of hydrocarbon

liquids (condensate) entrained in the emission stream, thus conserving

a valuable non-renewable resource. Properly operated condensers used at

TEG dehydration units, that have a flash tank in the overall

dehydration system design, have a HAP/volatile organic compound (VOC)

control efficiency of 95 percent.

The application of condensers and flares to area source TEG

dehydration units have been observed on actual operating units that are

typical of those in this industry. Thus, condensers and flares are a

technically feasible and demonstrated control option for area source

TEG dehydration units.

The economic impact analysis performed to evaluate the impacts of

the major and area source provisions of the proposed regulation

supports the area source finding. The results of this economic analysis

are summarized in section IV of this preamble.

The total annual social cost of the regulation is estimated to be

$10 million for major and area sources combined (approximately $4.0

million for major sources and $6.2 million for area sources). This

value accounts for the compliance cost imposed on producers, as well as

market adjustments that influence the revenues to producers and

consumption by end-users, plus the associated deadweight loss to

society of the reallocation of resources.

Regulation of area source TEG dehydration units in the oil and

natural gas production source category is supported by: (1) The

estimated MIR of 3 x 10-4 for HAP emissions from this area

source category, (2) technically feasible, effective, and demonstrated

control options (condensers and flares) that are readily available for

reducing emissions from area source TEG dehydration units, and (3) the

results the economic impact analysis that supports the minimal economic

impact associated with installation of the identified control options.

The EPA is proposing criteria that would target area source TEG

dehydration units for control: (1) Which have benzene emissions, (2)

that can be cost-effectively controlled, and (3) where potential human

exposures are greatest. These criteria are based on actual natural gas

throughput, benzene emission rate, and location in a county classified

as urban.

The actual natural gas throughput (on an annual average basis)

action levels for area source TEG dehydration units analyzed by the EPA

were: (1) 113 thousand m3/day (4.0 MMSCF/D) or greater, (2)

85 thousand m3/day (3.0 MMSCF/D) or greater, (3) 42 thousand

m3/day (1.5 MMSCF/D) or greater, and (4) 8.5 thousand

m3/day (0.3 MMSCF/D) or greater. Based on its evaluation of

projected impacts and the cost-effectiveness of installed controls, the

EPA selected 85 thousand m3/day (3.0 MMSCF/D) actual natural

gas

[[Page 6300]]

throughput as an action level for area source TEG dehydration units.

The EPA also selected an action level for area sources based on

actual benzene emissions from each area source TEG dehydration unit.

Benzene is a known human carcinogen that is typically emitted from

glycol dehydration units.

In addition, the EPA selected location as a criterion for control

based on the county-level urban versus rural location of area source

TEG dehydration units. Only those area source TEG dehydration units

located in counties classified as urban (see section III of this

preamble) and also meeting or exceeding the actual natural gas

throughput and benzene emission rate action levels would be required to

install air emission controls for HAP under the proposed rule.

VI. Glycol Dehydration Unit Nationwide HAP Emissions Estimates

Glycol dehydration units are estimated to account for up to 90

percent of HAP emissions from the oil and natural gas industry. The EPA

used GRI-GLYCalcTM Version 3.0, an emissions estimation

computer program developed by GRI, to estimate HAP emissions from

glycol dehydration units. This program is regarded within industry and

the EPA as an accurate simulation tool for estimating emissions of

organic compounds from glycol dehydration units.

The EPA developed HAP, VOC, and methane emission estimates for a

series of representative model glycol dehydration units representative

of those that operate within this industry. Nationwide emissions were

then estimated by extrapolating from model glycol dehydration unit

estimates.

Two inputs to the methodology used by the EPA to estimate

nationwide HAP emissions from glycol dehydration units that greatly

influence the result are: (1) The average HAP concentration of field

natural gas prior to the first processing stage, and (2) the average

total number of times that natural gas is dehydrated by all dehydration

methods between the wellhead and the end user. Based on extensive

discussions with industry, and review of available information and

application of engineering judgment, the EPA selected a value of 200

ppmv for the average BTEX concentration of field natural gas and a

value of 1.6 for the average number of times that natural gas is

dehydrated by all dehydration methods between the wellhead and the end

user. Estimated HAP emissions from all glycol dehydration units (at

both major and area sources of HAP) are 55,000 Mg/yr.

The EPA acknowledges that there are uncertainties inherent in any

estimate of nationwide HAP emissions for industries as large and as

diverse as the oil and natural gas production or natural gas

transmission and storage source categories. However, the EPA believes

that the engineering judgments and methodology used in developing the

nationwide HAP emissions estimates for these industries are reasonable

given the available information. The EPA requests comment on the

methodology and engineering judgments made when developing the

nationwide glycol dehydration unit HAP emissions estimates for these

source categories. The EPA specifically requests alternative emission

estimation methodologies, supported by documentation demonstrating how

an alternative methodology would yield improved estimates.

VII. Definition of Major Source for the Oil and Natural Gas Industry

A. Definition of ``Associated Equipment''

Whether a facility is a major source or an area source of HAP

emissions under section 112 of the Act is important for two reasons.

First, different requirements may be established for major and area

sources. Second, a source that is a major source under section 112 of

the Act is also subject to requirements for major sources under the

Federal operating permit program authorized by title V of the Act. Area

sources may also be subject to title V permitting requirements, but the

EPA has discretion to defer or waive these requirements.

For some oil and natural gas operations, it is clearly apparent

what constitutes a facility (e.g., a natural gas processing plant). For

others, however, it may not be clear what constitutes a facility. This

is particularly true for field operations in the oil and natural gas

production source category.

An oil or natural gas production field, for example, may cover many

square miles. Within this area, there can be a large number of

production wells, connected by pipeline, to small (satellite) or larger

(centralized) locations, such as tank batteries, where storage or

intermediate processing occurs prior to transmission to further

processing steps. Leasing and mineral rights agreements can give oil

and natural gas companies control over a large area of contiguous

property.

According to the statutory definition in section 112(a)(1), HAP

emissions from all emissions points within a contiguous area and under

common control must be counted in a major source determination. A

strict interpretation of the statutory definition of major source as

applied to this industry could mean that HAP emissions must be

aggregated from emission points separated by considerable distances.

This distance could be well beyond the distances that separate

equipment at a typical facility.

The Congress addressed the unique aspects of the oil and natural

gas production industry in special provisions included in section

112(n)(4) of the Act that apply to HAP emissions from oil and natural

gas wells and pipeline and compressor facilities. Section 112(n)(4)(A)

states

Notwithstanding the provisions of subsection (a), emissions from any

oil or gas exploration or production well (with its associated

equipment) and emissions from any pipeline compressor or pump

station shall not be aggregated with emissions from other similar

units, whether or not such units are in a contiguous area or under

common control, to determine whether such units or stations are

major sources, and in the case of any oil and gas exploration or

production well (with its associated equipment), such emissions

shall not be aggregated for any purpose under this section.

The language in section 112(n)(4)(A) makes it clear that, for the

purpose of implementing standards for major sources under section

112(d) for this industry, HAP emissions from oil and natural gas

exploration and production wells with their associated equipment cannot

be aggregated in making major source determinations.

However, the statutory language provides no definition of

``associated equipment.'' Neither is a clear intent evident in the

legislative history of the Act's 1990 amendments. The legislative

history does indicate that the Congress, in drafting section 112(n)(4),

believed that wells and their associated equipment generally: (1) Have

low HAP emissions, and (2) are typically located in widely dispersed

geographic areas, rather than concentrated in a single area.

A definition of associated equipment is important to implementing

standards for this industry for two reasons. First, because the statute

prevents the aggregation of HAP emissions from wells and their

associated equipment in making major source determinations, the

definition of associated equipment can influence which sources are

subject to requirements for major sources and which are subject to

requirements for area sources. Second, the definition of associated

equipment affects the regulation of area sources in the oil and natural

gas source category. Section 112(n)(4)(B) states

[[Page 6301]]

The Administrator shall not list oil and gas production wells (with

its associated equipment) as an area source under subsection (c),

except that the Administrator may establish an area source category

for oil and gas production wells located in any metropolitan

statistical area with a population in excess of 1 million, if the

Administrator determines that emissions of hazardous air pollutants

from such wells present more than a negligible risk of adverse

effects to public health.

Thus, production wells (with their associated equipment) may not be

regulated as an area source, but production wells as an individual area

source may be regulated by the Administrator under section 112(n)(4)(B)

upon an adverse risk determination.

In the absence of clear guidance in the statute, the EPA considered

options for defining associated equipment. In extensive discussions

with industry and trade association representatives, the EPA evaluated

a wide range of options.

One option considered was a definition based on a narrow

interpretation of associated equipment that would include only limited

equipment in close proximity to a well as associated with that well.

Another option considered was a definition based on a broad

interpretation of associated equipment that would extend the inclusion

of equipment far beyond the well as associated equipment. The initial

options considered by the EPA for defining associated equipment and the

EPA's assessment of each are discussed below.

The narrowest interpretation option would be that a well and its

associated equipment consists of only the well, defined as all

equipment below the ground surface, and the pressure maintenance and

flow control device attached to the well. For an exploratory well, the

typical pressure maintenance and flow control device is the blow out

preventer (BOP). For a production well, the typical pressure

maintenance and flow control device is referred to as the ``Christmas

tree,'' which may include a BOP. This interpretation would provide a

technical meaning to the term associated equipment, but would provide

limited substantive meaning.

As a practical matter, the term ``well with its associated

equipment'' under this option would not provide any additional relief

to industry from the aggregation of HAP emissions in a major source

determination beyond what would have been provided if Congress had only

used the term ``well'' in section 112(n)(4) of the Act. On this basis,

the EPA did not select this narrow interpretation for proposal.

An option initially suggested by industry is that all production

equipment be considered associated equipment. This is the broadest

possible interpretation of the term associated equipment and would

extend the definition to the boundaries of the source category, which

are (1) to the point of custody transfer for hydrocarbon liquids and

(2) to the natural gas transmission and storage source category for

natural gas. Under this interpretation, industry maintains that no

aggregation of HAP emissions should be allowed, even in situations

commonly acknowledged to be a single facility. Only individual emission

points which, by themselves, emit 10 tpy or more of any one HAP or 25

tpy or more of any combination of HAP would be regulated as major

sources under this interpretation.

The EPA rejects this broad interpretation as an option for defining

associated equipment for several reasons. First, an interpretation of

the language in section 112(n)(4) that would define all equipment as

associated with a well, regardless of (1) the type of equipment, (2)

any processing or commingling of streams that may occur, or (3)

distance from the well, would suggest that the Congress intended that

aggregation of HAP emissions not be allowed within this industry under

any circumstances. When viewed within the framework of section 112, the

EPA does not believe this to be the case.

For example, a natural gas processing plant has numerous HAP

emission points closely grouped together. These points may include one

or more glycol dehydration units, condensate storage vessels, several

gas treatment and separation steps, and various containers. These HAP

emission points may emit, in total, HAP in excess of 25 tpy. Each HAP

emission point within the natural gas processing plant, however, may

emit less than 10 tpy of any one HAP or 25 tpy of any combination of

HAP.

If all equipment within the plant were defined as associated

equipment, then the plant would not be considered a major source

subject to MACT standards. It is, therefore, conceivable that the

natural gas processing plant that meets the criteria of a major source

could go unregulated by MACT standards under this scenario, even though

surrounding populations were exposed to HAP emissions at a level that

would trigger the application of MACT standards in other similar

industries.

In addition, this option would include (as associated equipment)

HAP emission points that the EPA has determined are large individual

sources of HAP. In particular, available information indicates that

glycol dehydration units and storage vessels emit substantial

quantities of HAP.

Glycol dehydration units are the largest identified HAP emission

point in the oil and natural gas production source category, accounting

for about 90 percent of estimated total HAP emissions from this source

category based on available information used in the EPA's analysis.

Individually, glycol dehydration units may emit total HAP in amounts

from less than 0.9 Mg/yr to substantially above major source levels.

Also, a single storage vessel with flash emissions may emit several

megagrams of HAP per year.

The EPA firmly believes that glycol dehydration units and storage

vessels with flash emissions are not the type of small HAP emission

points that Congress intended to be included in the definition of

associated equipment. Further, as previously discussed in section V of

this preamble, the EPA has made an area source finding that benzene

emissions from TEG dehydration units pose a significant risk to public

health.

The EPA does not intend to regulate TEG dehydration units that emit

small amounts of HAP. However, the EPA has an obligation to provide

public health protection where there is risk from exposure to HAP

emissions. If TEG dehydration units were included as associated

equipment, the EPA's ability to provide protection to persons at risk

from exposure would be severely limited through section 112(n)(4)(B).

For all the reasons set out above, defining all equipment as

associated equipment was rejected as an option for proposal by the EPA.

However, the EPA believes that the use of custody transfer within an

interpretation (along with other criteria) is a good method for

delineating between equipment that is associated and not associated

with a well.

A variety of interpretations of associated equipment intermediate

of those two extremes are also possible. Through discussions with

industry and trade association representatives, the EPA considered

several intermediate options based on drawing a line of demarcation

downstream from the well. Equipment before this line of demarcation

would be deemed to be associated with a well and equipment beyond the

line would not be considered associated. The point in the processing of

oil or natural gas at which such a line of demarcation could be drawn

might be tied to where a certain product processing or transfer step

takes place.

[[Page 6302]]

Three intermediate options, using this approach, define associated

equipment as including all equipment up to (1) the point where initial

processing of an extracted hydrocarbon stream takes place, (2) the

point of physical commingling of the extracted hydrocarbon stream with

streams from other wells, and (3) the point of custody transfer, with

exceptions for selected affected sources.

The EPA evaluated each of these options with several objectives in

mind. First, the option chosen should provide substantive meaning to

the term associated equipment and prevent the aggregation of small,

scattered HAP emission points in major source determinations. Second,

the option chosen should be easily implementable. That is, it should be

clear to the regulated community and enforcement personnel what is

associated equipment and what is not associated equipment. Finally, the

option chosen should not preclude the aggregation of the most

significant HAP emission points in the source category. Additionally,

the option chosen should not restrict the EPA's ability to regulate

glycol dehydration units as area sources.

An option tied to the point of initial processing would meet only

the last of these objectives. Initial processing for many extracted

hydrocarbon liquid and natural gas streams occurs immediately after the

stream has left the well. Typical processing steps that may occur at a

well site include gas/oil separation, heating/treating, and

dehydration. The only equipment in addition to the Christmas tree that

would be included as associated equipment under this option would be

storage vessels in which no treating or separation takes place.

Thus, little additional relief from HAP emission aggregation would

be provided by an associated equipment definition based on initial

processing. Also, the term ``point of initial processing'' is not a

term commonly used and understood in the source category, a fact that

would likely lead to confusion between enforcement agencies and the

regulated community.

Selecting an option based on the point of physical commingling of

streams would provide additional substantive meaning to the term

associated equipment and possible relief from HAP emission aggregation

in situations where a stream from a single well undergoes processing

prior to mixing with streams from other wells (the storage vessels and

processing equipment would be associated with that well). However, the

EPA sees great potential for confusion under this option, as the same

equipment that would be considered associated equipment at a single

well facility might not be associated equipment where streams from

multiple wells are combined prior to processing.

Another option is the use of the point of custody transfer in

combination with allowing HAP emission aggregation for selected

affected sources. For the proposed production regulation, the EPA

defines custody transfer (which has been previously defined in other

standards) as transfer, after processing and/or treatment in the

producing operations, from storage vessels or automatic transfer

facilities to pipelines or any other forms of transportation. The EPA

considers the point at which natural gas enters a natural gas

processing plant as a point of custody transfer for the proposed

regulation.

From an implementation perspective, this is an attractive option.

According to industry and trade association representatives, the term

custody transfer is commonly used and understood within the oil and

natural gas production source category. Selecting this option would

simplify the owner or operator's regulatory compliance determination

for a specified piece of equipment. The point of custody transfer often

denotes contractually the point of change in ownership of equipment or

product. Therefore, defining associated equipment as all equipment up

to the point of custody transfer is a good approach for delineating a

line of demarcation between equipment that is associated and equipment

that is not associated. This approach is the same as the broadest

interpretation of associated equipment as initially proposed by

industry, however, selected affected sources are not included as

associated equipment.

Glycol dehydration units and storage vessels with flash emissions

are often located before the point of custody transfer. Many glycol

dehydration units, for example, are located on single wells or at

condensate tank batteries. As discussed previously, the EPA feels

strongly that because glycol dehydration units and storage vessels with

flash emissions are significant sources of HAP emissions, they are not

the HAP emission points intended by Congress to be associated equipment

under section 112(n)(4).

Therefore, the EPA is proposing that associated equipment be

defined as all equipment associated with a production well up to the

point of custody transfer, except that glycol dehydration units and

storage vessels with flash emissions would not be associated equipment.

The EPA believes that this proposed definition will provide the relief

that Congress intended in section 112(n)(4) while preserving the EPA's

ability to require appropriate MACT or GACT controls for the most

significant identified HAP emission points in the oil and natural gas

production source category. The EPA considers the point at which

natural gas enters a natural gas processing plant as a point of custody

transfer for natural gas streams and HAP emission aggregation is

allowed at natural gas processing plants. Natural gas processing plants

are included in the scope of the oil and natural gas production NESHAP.

B. Definition of Facility

As discussed in the previous section, it is not clear for many oil

and gas field operations what constitutes a facility and, consequently,

exactly where facility boundaries exist for the purpose of a major

source determination. With many operations connected by pipeline and

located on common oil and gas leases that extend for miles, the meaning

of the phrase, ``located within a contiguous area under common

control,'' used in section 112(a)(1) of the Act to describe sources

that should be grouped in a major source determination, is not often

clear when applied to oil and natural gas field operations. Relief from

the possible need to aggregate emissions from certain small, widely

dispersed, HAP emission sources is provided in the language of section

112(n)(4), and in the EPA's proposed definition of associated

equipment. However, potential for confusion still exists concerning

when non-associated equipment should be aggregated. Thus, the EPA is

proposing further clarification of what constitutes a facility for the

purposes of major source determinations in the oil and natural gas

production and natural gas transmission and storage source categories.

The EPA's objective in developing a definition of facility for this

proposed rulemaking is to identify criteria that would define a

grouping of emission points that meet the intent of the section

112(a)(1) language, ``located within a contiguous area and under common

control,'' but in terms that are meaningful and easily understood

within the regulated industries. Examples of general facility types in

the oil and natural gas production source category include natural gas

processing plants, offshore production platforms, central tank

batteries, satellite tank batteries, and individual well sites.

Compressor stations and underground storage facilities are examples of

[[Page 6303]]

facilities in the natural gas transmission and storage source category.

Though some facilities in the oil and natural gas production source

category, such as natural gas processing plants, fit the profile of a

typical industrial facility and are easy to define, other facilities

(e.g., production field facilities) do not fit the typical profile.

Substantial differences exist between the majority of typical oil and

natural production field operations and traditional industrial

facilities that are regulated under the Act. Industrial facilities

typically have distinct physical boundaries or fencelines. Emission

points at these facilities are generally in close proximity to or

collocated with one another (contiguous) and located within an area

boundary, the entirety of which (other than roads, railroads, etc.) is

under the physical control of the same owner (common ownership).

Typical oil and natural gas production field facilities do not

adhere to this profile. The owners or operators of production field

facilities typically do not own or control the surface property that

lies between two or more production field facilities. Rather, the

owners or operators of production field facilities control only the

surface area that is necessary to operate the physical structures used

in oil and natural gas production. Production facilities may be

connected by underground flow or gathering lines but are essentially

separate independent facilities. Production equipment sharing the same

close physical location (e.g., a well site, tank battery, or graded

pad) is likely to be under common control and in a contiguous area.

However, production equipment that is physically separated within or

across leases (to serve different wells and connected by flow or

gathering lines) is not contiguous based on surface rights and is not

likely to be under common control.

The EPA intends that a facility definition as it applies to the oil

and natural gas production source category should lead to an

aggregation of emissions in a major source determination that is

reasonable, consistent with the intent of the Act, and easily

implementable. In this source category, functionally related equipment

is generally located at what is referred to as the same surface site.

Surface site means the graded pad, gravel pad, foundation, platform, or

immediate physical location on which equipment is located. Defining

facility based on individual surface site would, in the EPA's view,

identify groupings of equipment on which major source determinations

would be made that are consistent with the EPA's intent. For example, a

definition on this basis would require aggregation of emissions from

significant HAP emission sources that are closely grouped, such as two

or more glycol dehydration units on the same graded pad treating a

natural gas stream. Glycol dehydration units located on different

graded pads, for example at separate tank batteries, would presumably

not be functionally related (i.e., the units treat different streams)

and in most cases would be separated by considerable distance.

Consequently, the EPA does not believe it would be reasonable to

combine emissions from these units. Finally, because the term surface

site is well understood within industry and easily recognizable by

enforcement authorities, a facility definition on this basis should be

easily implementable. For these reasons, the EPA is proposing a

facility definition based on individual surface site. For further

clarification, the EPA is also proposing that equipment located on

different oil and gas properties (oil and gas lease, mineral fee tract,

subsurface unit area, surface fee tract, or surface lease track) shall

not be aggregated.

Another objective of the EPA in developing a definition of facility

was to minimize, where possible and reasonable, the burden on owners

and operators in making a major source determination. The EPA's

evaluation of HAP emission sources in production field operations

indicates that the two primary HAP emission points at field operation

facilities are glycol dehydration units and storage tanks with flash

emissions, and that other potential HAP emission points at these

facilities (e.g., equipment leaks) will be inconsequential to the

determination of a facility's major source status. Therefore, the EPA

is proposing that for the purpose of a major source determination, a

production field facility would be limited to glycol dehydration units

and storage tanks with flash emission potential. The EPA believes that

by eliminating the need to quantify HAP emissions from small sources at

such facilities, the burden on an owner or operator to make a major

source determination would be greatly reduced, while still ensuring an

accurate classification of the facility as a major or area source of

HAP emissions.

The EPA specifically requests comments on the proposed definition

of facility. Specifically the EPA requests comments on whether the

proposed definition appropriately implements the intent of the major

source definition in section 112(a)(1) for the oil and natural gas

production and natural gas transmission and storage source categories,

or if another definition would better implement this intent.

VIII. Rationale for Proposed Standards

A. Selection of Hazardous Air Pollutants for Control

The EPA believes that it is not appropriate to select all organic

HAP listed under section 112(b) of the Act for regulation under the

proposed NESHAP. Of the 188 compounds listed, only a limited number are

emitted from oil and natural gas facilities. Consequently, the EPA

developed a list of the specific HAP to be regulated in the proposed

rules. However, all 188 listed HAP must be considered in any major

source determination under the General Provisions to 40 CFR Part 63.

To select which HAP are to be regulated under the proposed NESHAP,

the EPA evaluated the potential for HAP to be emitted from oil and

natural gas facilities. Based on this evaluation, the EPA is proposing

that the following specific HAP be regulated under the proposed NESHAP:

acetaldehyde, benzene (including benzene in gasoline), carbon

disulfide, carbonyl sulfide, ethyl benzene, ethylene glycol,

formaldehyde, n-hexane, naphthalene, toluene, 2,2,4-trimethylpentane

(iso-octane), and mixed xylenes, including o-xylene, m-xylene, and p-

xylene.

The EPA decided to develop a set of control options for this

industry to control HAP emissions as a class rather than developing a

series of control options to control emissions of each individual HAP

on the list. Consequently, the control options considered are directed

towards the control of total HAP emissions.

B. Selection of Emission Points

The EPA identified the primary types of HAP emission points at oil

and natural gas facilities. The three primary HAP emission point types

are (1) process vents, (2) storage vessels, and (3) equipment leaks.

The primary process vent HAP emission point is the glycol

dehydration unit reboiler vent. A glycol dehydration unit reboiler

regenerates glycol used in the dehydration of natural gas by separating

the water from the glycol. The glycol also attracts aromatic compounds,

including BTEX and n-hexane during the dehydration process. These HAP,

along with the water vapor and other gases, are emitted through the

glycol dehydration unit reboiler vent.

In addition, glycol dehydration units may incorporate the use of a

gas condensate glycol separator (GCG separator or flash tank). The rich

glycol,

[[Page 6304]]

which has absorbed water vapor from the natural gas stream, leaves the

bottom of the absorption column of a glycol dehydration unit and is

directed either to (1) GCG separator (flash tank) and then a reboiler

or (2) directly to a reboiler where the water is boiled off the rich

glycol. If the system includes a GCG separator (flash tank), the gas

separated from the rich glycol is typically (1) recycled to the header

system, (2) used for fuel, or (3) used as a stripping gas. The GCG

separator (flash tank) vent is a potential HAP emission point if vented

to the atmosphere.

Other potential HAP emission point process vents are the tail gas

streams from amine treating processes and sulfur recovery units.

Limited data have been identified that indicate the potential for HAP

emissions from these operations. Thus, HAP emissions from amine

treating processes and sulfur recovery units have not been estimated.

Recent research published by GRI indicates that these emission points

have the potential to be significant sources of HAP emissions. Comment

is requested on potential HAP emissions and emission rates from these

operations and potential applicable air emission controls.

Storage vessels have also been identified as a HAP emission point.

Storage vessels used in the oil and natural gas industry include

storage vessels with flash emissions. Storage vessels in the oil and

natural gas production source category are commonly equipped with fixed

roofs. Emissions from fixed-roof storage vessels with flash emissions

are a result of breathing, working, and (primarily) flash losses.

Pipeline pigging and storage of pipeline pigging wastes is a

potential HAP emission point in the transmission sector of the oil and

natural gas industry. Only limited qualitative data have been

identified that indicate the potential for HAP emissions from this

operation. Thus, HAP emissions have not been estimated. Comment is

requested on potential HAP emissions from storage of pipeline pigging

wastes and potential applicable emission controls.

Valves, pump seals, and other pieces of equipment servicing HAP-

containing streams have the potential to leak. A majority of facilities

in the oil and natural gas industry do not have LDAR programs.

Therefore, equipment leaks from that equipment servicing HAP-containing

streams have been identified as a potential HAP emission point.

In addition to the above HAP emission points, the EPA evaluated the

potential regulation of other HAP emission points. These included (1)

containers, (2) equipment leaks at tank batteries and offshore

production platforms, (3) production surface impoundments, and (4)

waste and wastewater management units.

Insufficient data were submitted in the Air Emissions Survey

Questionnaire responses for the other potential HAP emission points of

containers, equipment leaks at tank batteries and offshore production

platforms, production surface impoundments, and waste and wastewater

management units to allow for determination of existing control levels.

Thus, a review of other data sources was conducted to identify

information on existing control levels for these potential HAP emission

points.

For these other HAP emission points, the review of available

information did not indicate any apparent pattern of existing emission

controls. Thus, it has been determined that the existing level of

control for this collection of other HAP emission points is no control.

C. Definition of Affected Source

The term affected source is used in part 63 regulations to

designate the emission sources or group of sources that are regulated

by a standard. Each standard must define what the affected source is

for purposes of that specific standard.

The EPA has discretion to establish a narrow or broad definition of

affected source, as appropriate for a particular rule. A broad

definition would be in terms of groups of equipment. A narrow

definition would designate specific pieces of equipment or emission

points as separate affected sources.

For the proposed oil and natural gas production and natural gas

transmission and storage NESHAPs, a narrow definition of affected

source is proposed for most HAP emission points. The affected sources

under the oil and natural gas production NESHAP include (1) each glycol

dehydration unit located at a major source of HAP, (2) each TEG

dehydration unit located at an area source of HAP, and (3) each storage

vessel with flash emissions located at a major source of HAP.

For the proposed standards for equipment leaks at natural gas

processing plants, the EPA is proposing a broad definition of affected

source. Specifically, the group of equipment targeted by fugitive

emission standards (pumps, pressure relief devices, valves, flanges,

etc. that operate in organic HAP service) are designated as one

affected source, except that compressors would each be a separate

affected source. The implication of this broader definition is that the

replacement of an individual component, such as a valve, would not be

considered the construction of a new affected source, which triggers

reporting requirements for new sources.

The affected source under the natural gas transmission and storage

NESHAP is each glycol dehydration unit located at a major source of

HAP.

D. Determination of MACT Floor

As described in this preamble, the Act defines a minimum level of

control for standards established under section 112(d), referred to as

the MACT floor. For a source category with 30 or more sources, such as

with the oil and natural gas production and natural gas transmission

and storage source categories, the MACT floor for existing sources

shall not be less stringent than the average emission limitation

achieved in practice by the best performing 12 percent of existing

sources. Standards more stringent than the floor may be established

based on a consideration of cost, environmental, energy, and other

impacts.

The EPA is to establish standards based on available information.

Available information for the MACT floor analysis for these source

categories consists primarily of data gathered from industry responses

to survey questionnaires. The surveys were designed to collect

information representative of processes and operations in these source

categories.

1. MACT Floor for Existing Sources

Oil and Natural Gas Production-Glycol Dehydration Unit Vents;

Natural Gas Transmission and Storage-Glycol Dehydration Unit Vents. The

MACT floor for all process vents at glycol dehydration units (including

area source TEG dehydration units in the oil and natural gas production

source category) is 95 percent HAP emission reduction, which correlates

with the existing control level estimated to be achieved through the

use of condensers.

Oil and Natural Gas Production-Storage Vessels. The MACT floor for

existing storage vessels containing material with a GOR equal to or

greater than 50 m \3\ (1,750 ft \3\) per barrel or an API gravity equal

to or greater than 40 deg. and an actual throughput equal to or greater

than 500 BPD (i.e., storage vessel with flash emissions) is the

installation and operation of a cover that is connected through a

closed-vent system to a 95 percent efficient control device. A

pressurized storage vessel that is designed to operate as a closed

system is considered in compliance with the requirements for storage

vessels.

[[Page 6305]]

Oil and Natural Gas Production-Equipment Leaks. The MACT floor

levels for equipment leaks apply only to those components at natural

gas processing plants handling material with a total HAP content equal

to or greater than 10 percent by weight.

The MACT floor for equipment leaks at natural gas processing plants

is judged to be at the new source performance standard (NSPS) level of

control for natural gas processing plants. The NSPS level of control is

equal to that of 40 CFR part 61, subpart V (equipment leaks NESHAP).

Since the pollutants targeted for control under the proposed standards

are HAP, the proposed standards cross-reference the requirements from

the equipment leaks NESHAP.

The proposed standards require monthly monitoring of equipment with

a leak definition of 10,000 ppmv VOC. Based on the component counts and

other characteristics of the model natural gas processing plants, it is

estimated that the NESHAP LDAR program would attain a 70 percent HAP

emission reduction from uncontrolled cases. The proposed standards

allow existing natural gas processing plants subject to the NSPS to

comply only with those requirements.

2. MACT Floor for New Sources

In the review of available information, the EPA did not identify a

method of control applicable to all types of new sources that would

achieve a greater level of HAP emission reduction than the MACT floor

for existing sources. Therefore, the MACT floor for new sources in the

oil and natural gas production and natural gas transmission and storage

source categories is the same as the MACT floor for existing sources.

E. Oil and Natural Gas Production NESHAP-Regulatory Alternatives for

Existing and New Major Sources

The EPA evaluated two regulatory alternatives for existing and new

major sources in the oil and natural gas production source category.

The first regulatory alternative is the MACT floor levels for the

identified HAP emission points. A second regulatory alternative was

evaluated that included the installation of combustion control systems

for process vents and storage tanks at all impacted major sources.

Combustion systems typically have a control efficiency of 98 percent,

or greater, as compared with the control systems in Regulatory

Alternative 1, which achieve an emission reduction efficiency of 95

percent.

Regulatory Alternative 1 (MACT floor) would achieve a nationwide

decrease in HAP emissions from all HAP emission points at major sources

of approximately 77 percent. In the EPA's judgement, the costs (and the

associated cost-effectiveness) of going beyond the floor would be

greatly disproportional to the additional HAP emission reduction that

would be achieved. The costs and average and incremental cost-

effectiveness of the two regulatory alternatives are presented in Table

4. Based on this and other information, the EPA selected Regulatory

Alternative 1 (MACT floor) as the basis for the proposed standards. In

addition, the EPA did not select Regulatory Alternative 2 since the

control options evaluated (combustion systems) involved the destruction

of a recoverable non-renewable resource and did not encourage the

application of pollution prevention techniques.

Table 4.--Comparison of Regulatory Alternative Cost Impacts for the

Proposed Oil and Natural Gas Production Standards--Major Source

Provisions

------------------------------------------------------------------------

Regulatory alternative

Cost category --------------------------------

1 (MACT floor) 2

------------------------------------------------------------------------

Implementation costs (Million of July

1993 $):

Total installed capital............ 6.5 18

Total annual....................... 4.0 23

Cost-effectiveness ($/Megagram HAP):

Average............................ 130 740

Incremental........................ ............... 19,000

------------------------------------------------------------------------

These standards would impact those glycol dehydration units, at

major sources, with an actual natural gas throughput equal to or

greater than 85 thousand m\3\/day (3.0 MMSCF/D), on an annual average

basis, unless it is demonstrated that benzene emissions from the unit

were less than 0.9 Mg/yr (1 tpy).

F. Oil and Natural Gas Production NESHAP-Regulatory Alternatives for

Existing and New Area Sources

The EPA evaluated four regulatory alternatives for TEG dehydration

units at existing and new area sources at oil and natural gas

production sources. Each regulatory alternative is characterized in

terms of an action level, above which HAP emissions must be controlled.

The action levels considered are expressed as the actual annual average

flow rate of natural gas (in thousand m\3\/day (MMSCF/D)) to the TEG

dehydration unit. The action levels for the regulatory alternatives are

(1) 113 thousand m\3\/day (4.0 MMSCF/D) or greater, (2) 85 thousand

m\3\/day (3.0 MMSCF/D) or greater, (3) 42 thousand m\3\/day (1.5 MMSCF/

D) or greater, and (4) 8.5 thousand m\3\/day (0.3 MMSCF/D) or greater.

Based on an evaluation of the projected action level impacts and

costs-effectiveness, the EPA selected Regulatory Alternative 2 as

representative of GACT for TEG dehydration units at area sources of

HAP. Alternative 2 would impact those TEG dehydration units with an

actual natural gas throughput equal to or greater than 85 thousand

m\3\/day (3.0 MMSCF/D), on an annual average basis, unless it is

demonstrated that benzene emissions from the unit were less than 0.9

Mg/yr (1 tpy).

It is the objective of the EPA to structure the rules for area

sources in a way that protects exposed populations. The EPA also needs

to minimize the cost to industry to control units where there would be

less human exposure and overall cancer incidence from exposure to HAP

emissions from area source TEG dehydration units.

Therefore, the EPA is proposing a criterion that no unit would have

to be controlled if it is demonstrated that emissions of benzene from

the unit are less than 0.9 Mg/yr (1 tpy), either uncontrolled or with

controls in place under federally enforceable limits. As noted

previously, benzene is a known human carcinogen that is typically

emitted from TEG dehydration units.

[[Page 6306]]

The EPA is also proposing the use of a population-based action

level in conjunction with the actual natural gas throughput and benzene

emission rate action levels for area source TEG dehydration units. The

EPA selected an action level based on the county-level urban versus

rural location of area source TEG dehydration units. Only those

selected area source TEG dehydration units located in counties

classified as urban (see section III of this preamble) and also meeting

or exceeding the actual natural gas throughput and benzene emission

rate action levels will be required to install air emission controls on

all process vents.

G. Natural Gas and Transmission NESHAP-Regulatory Alternatives for

Existing and New Major Sources

The EPA evaluated two regulatory alternatives for existing and new

major sources in the natural gas transmission and storage source

category. The first regulatory alternative is the MACT floor level for

all process vents at glycol dehydration units. A second regulatory

alternative was evaluated that included the installation of combustion

control systems for process vents at all impacted major sources.

Combustion systems typically have a control efficiency of 98 percent,

or greater, as compared with the control systems in Regulatory

Alternative 1 which achieve an emission reduction efficiency of 95

percent.

Regulatory Alternative 1 (MACT floor) would achieve a nationwide

decrease in HAP emissions from major sources of approximately 95

percent. The costs and the associated cost-effectiveness of going

beyond the floor would be greatly disproportional to the additional HAP

emission reduction that would be achieved. The costs and average and

incremental cost-effectiveness of the two regulatory alternatives are

presented in Table 5. Based on this and other information, the EPA

selected Regulatory Alternative 1 (MACT floor) as the basis for the

proposed standards. In addition, the EPA did not select Regulatory

Alternative 2 since the control options evaluated (combustion systems)

involved the destruction of a recoverable non-renewable resource and

did not encourage the application of pollution prevention techniques.

Table 5.--Comparison of Regulatory Alternative Cost Impacts for the

Proposed Natural Gas Transmission and Storage Standards

------------------------------------------------------------------------

Regulatory alternative

Cost category -------------------------------

1 (MACT floor) 2

------------------------------------------------------------------------

Implementation costs (Thousand of July

1993 $):

Total installed capital............. 57 230

Total annual 46 250

Cost-effectiveness ($/Megagram HAP):

Average............................. 420 2,100

Incremental......................... .............. 20,000

------------------------------------------------------------------------

H. Selection of Format

Section 112(d) of the Act requires that emission standards for

control of HAP be prescribed unless, in the judgement of the

Administrator, it is not feasible to prescribe or enforce emission

standards. Section 112(h) identifies two conditions under which it is

not considered feasible to prescribe or enforce emission standards.

These conditions include (1) if the HAP cannot be emitted through a

conveyance device or (2) if the application of measurement methodology

to a particular class of sources is not practicable due to

technological or economic limitations. If emission standards are not

feasible to prescribe or enforce, then the Administrator may instead

promulgate equipment, work practice, design or operational standards,

or a combination thereof.

Formats for emission standards include (1) percent reduction, (2)

concentration limits, or (3) a mass emission limit. For the proposed

NESHAPs, standards solely expressed as a percent, concentration, or

mass emission reduction would not alone appropriately reflect the

technologies on which the proposed standards are based and ensure that

the intended emissions reductions are achieved. Therefore, the proposed

standards are a combination of (1) emission standards and (2)

equipment, design, work practice, and operational standards.

The format chosen for glycol dehydration unit (including area

source TEG dehydration units subject to the proposed oil and natural

gas production NESHAP) process vent streams is a HAP weight-percent

reduction requirement that applies to the control device. A weight-

percent reduction format is appropriate for streams with HAP

concentrations above 1,000 ppmv because such a format ensures the 95

percent control level requirement. The format for the proposed storage

vessel provisions is a combination of a weight-percent reduction and

inspection, repair, and work practice requirements. The inspection,

repair, and work practice requirements are necessary to ensure the

proper operation and integrity of control equipment.

For equipment leak sources, such as pumps and valves, the EPA has

previously determined that it is not feasible to prescribe or enforce

emission standards. Except for those items of equipment for which

standards can be set at a specific concentration. The only method of

measuring emissions is total enclosure of individual items of

equipment, collection of emissions for a specified time period, and

measurement of the emissions. This procedure, known as bagging, is a

time-consuming and prohibitively expensive technique considering the

great number of individual items of equipment in a typical process

unit.

The proposed standards for equipment leaks at natural gas

processing plants incorporate several formats, including equipment,

design, base performance levels, work practices, and operational

practices. The proposed formats are the same as for the natural gas

processing plant (on-shore) NSPS and the 40 CFR part 61, subpart V

equipment leaks (fugitive emissions) NESHAP.

I. Selection of Test Methods and Procedures

Test methods and procedures specified in the proposed standards

[[Page 6307]]

would be used to demonstrate compliance. Procedures and methods

included in the proposed standards are, where appropriate, based on

procedures and methods previously developed by the EPA for use in

implementing standards for sources similar to those being proposed for

regulation. Methods and procedures are included to determine the

following (1) no detectable emissions, (2) volatile organic HAP (VOHAP)

concentration, (3) control device performance (i.e., control-

efficiency), and (4) annual average flow rate of field natural gas to a

glycol dehydration unit.

J. Selection of Monitoring and Inspection Requirements

Control devices used to comply with the proposed standards need to

be properly operated and maintained if the standards are to be achieved

on a long-term basis. The EPA considered two monitoring options for

these NESHAPs (1) the use of CMS and (2) the use of monitors that

measure operating parameters that can be directly related to the

emission control performance of a particular control device.

The CMS that use gas chromatography to measure individual gaseous

organic HAP compound chemicals are not practical for applications where

multiple organic HAP chemicals are to be monitored, as is typical with

oil and natural gas production and natural gas transmission and storage

facilities.

An alternative is to use a CMS to measure total VOC or total

hydrocarbons (THC) as a surrogate for total organic HAP. These CMS,

however, provide a measure of the relative concentration level of a

mixture of organic chemicals, rather than a quantified level of the

organic species present.

Based on these reasons, the EPA rejected requiring the use of CMS

for the proposed NESHAPs. Instead, the EPA selected monitoring of

control device operating parameters indicative of air emission control

performance as the appropriate approach to monitoring.

The proposed NESHAPs specify the types of parameters that can be

monitored for common types of control devices. These parameters were

selected because they are good indicators of control device performance

and because continuous parameter monitoring instrumentation is

available at a reasonable cost. An owner or operator could be approved,

on a case-by-case basis, to monitor parameters not specifically listed

in the proposed standards.

The established operating parameters for each control device will

be incorporated in the operating permit issued for a facility (or, in

the absence of an operating permit, the established levels will be

directly enforceable) and will be used to determine a facility's

compliance status. Excursions outside the established operating

parameter values will be considered violations of the applicable

emission standards, except when the excursion is caused by a startup,

shutdown, or malfunction that meets the criteria specified in the part

63 General Provisions (40 CFR part 63 subpart A).

Continuous monitoring is not feasible for those emission points

required to comply with certain equipment standards and work practice

standards (e.g., storage vessels equipped with only covers, pumps and

valves subject to LDAR programs). In such cases, failure to install and

maintain the required equipment or properly implement the LDAR program

constitutes a violation of the applicable equipment or work practice

standards.

The owner or operator of a glycol dehydration unit that does not

install controls would be required to install a flow monitor to

demonstrate that the actual natural gas flow rate to the unit is less

than the action level of 85 thousand m\3\/day (3.0 MMSCF/D), on an

annual average basis. If a flow monitor is installed, it must have an

accuracy of within 2 percent.

K. Selection of Recordkeeping and Reporting Requirements

The EPA may require an owner or operator of a source to establish

and maintain records and prepare and submit notifications and reports.

General recordkeeping and reporting requirements for all NESHAP are

specified in the part 63 General Provisions (40 CFR 63.9 and 40 CFR

63.10).

The proposed standards would require sources to submit (1) initial

notification reports, (2) notification of compliance status reports,

and (3) other periodic reports (e.g., startup, shutdown and malfunction

report, excess emissions report, CMS performance test report).

All recordkeeping and reporting requirements proposed for major

sources are consistent with the General Provision requirements, except

that (1) the initial notification would not be due for a year and (2)

the startup, shutdown and malfunction report, excess emissions report,

and CMS performance test report would be required semi-annually rather

than quarterly unless otherwise specified by the State regulatory

authority.

The EPA is proposing fewer recordkeeping and reporting requirements

for oil and natural gas production area sources. Specifically, the

owners and operators of applicable area sources are not subject to (1)

the requirements in Sec. 63.6, paragraph (e) of the General Provisions

for developing and maintaining a startup, shutdown, and malfunction

plan or (2) the requirements in Sec. 63.10, paragraph (d) for reporting

actions consistent with the plan. The owners and operators of

applicable area sources are required to submit a report identifying

occurrences of startup, shutdown, or malfunction when these events

happen or are anticipated to happen.

Further, the periodic excess emissions reports and summary reports,

as described in Sec. 63.10 paragraph (e)(3) of the General Provisions,

are required on a less frequent basis than for major sources. For area

sources, these reports are required annually (i.e., major sources need

to submit these reports semi-annually). This was done to reduce the

recordkeeping and reporting burden on owners and operators of affected

facilities.

IX. Relationship to Other Standards and Programs under the Act

A. Relationship to the Part 70 and Part 71 Permit Programs

Under title V of the Act, the EPA established a permitting program

(part 70 and part 71 permitting program) that requires all owners and

operators of HAP-emitting sources to obtain an operating permit (57 FR

32251, July 21, 1992). Sources subject to the permitting program (i.e.,

oil and natural gas production and natural gas transmission and storage

sources) are required to submit complete permit applications within a

year after a State program is approved by the EPA or, where a State

program is not approved, within a year after a program is promulgated

by the EPA. If the State where the facility is located does not have an

approved permitting program, the owner or operator of a facility must

submit the application to the EPA Regional Office in accordance with

the requirements of the part 63 General Provisions (40 CFR 63 subpart

A).

In addition, section 502(a) of the Act expressly gives the

Administrator the discretion to exempt one or more area source

categories (in whole or in part) from the requirement to obtain a

permit under 42 U.S.C. 7661a(a).

* * * if the Administrator finds that compliance with such

requirements is impracticable, infeasible, or unnecessarily

burdensome on such categories.

[[Page 6308]]

One critical factor that the EPA considers as part of the

``unnecessarily burdensome'' criteria is the degree to which the

standard is implementable outside of a permit, such that the permit

would provide minimal additional benefit with regard to source-specific

tailoring of the standards.

All area source TEG dehydration units impacted by the provisions of

the proposed standards must (1) comply with the compliance schedule

within the rule, (2) perform monitoring of the required parameters for

ensuring compliance, and (3) follow the limited recordkeeping and

reporting requirements. Therefore, the primary goal of significant

reductions in HAP emissions, particularly BTEX and n-hexane, would be

achieved, regardless of whether a permit is required. Unless otherwise

required by the State, the owner or operator of an area source subject

to the proposed standards is not required to obtain a permit under part

70 of title 40 CFR.

B. Relationship Between the Oil and Natural Gas Production and the

Organic Liquids Distribution (Non-Gasoline) Source Categories

The EPA believes that a clear applicability demarcation is

necessary to distinguish those sources that would be subject to the

proposed oil and natural gas production NESHAP and those that would be

subject to the organic liquids distribution (non-gasoline) NESHAP,

which is scheduled for promulgation by the year 2000.

The proposed standards for the oil and natural gas production

source category identify the source category and applicability as

including facilities up to the point of custody transfer. The EPA

intends to define the organic liquids distribution (non-gasoline)

source category as including those facilities that handle and

distribute organic liquids (non-gasoline) from the point of custody

transfer.

C. Relationship of Proposed Standards to the Pollution Prevention Act

The Congress passed and the President signed into law the Pollution

Prevention Act of 1990 (PPA) making pollution prevention a national

policy. Section 6602(b) identifies an environmental management

hierarchy in which pollution

* * * should be prevented or reduced whenever feasible; pollution

that cannot be prevented should be recycled in an environmentally

safe manner, whenever feasible; pollution that cannot be prevented

or recycled should be treated in an environmentally safe manner,

whenever feasible; and disposal or other releases into the

environment should be employed only as a last resort * * *

In short, preventing pollution before it is created is preferable to

trying to manage, treat or dispose of it after it is created.

According to PPA section 6603, source reduction is defined as

reducing the generation and release of hazardous substances,

pollutants, wastes, contaminants or residuals at the source, usually

within a process. The term includes equipment or technology

modifications, process or procedure modifications, reformulation or

redesign of products, substitution of raw materials, and improvements

in housekeeping, maintenance, training, or inventory control. Source

reduction does not include any practice that alters the physical,

chemical, or biological characteristics or the volume of a hazardous

substance, pollutant, or contaminant through a process or activity that

is not integral to or necessary for producing a product or providing a

service.

Pertaining to these proposals, section 6604(b)(2) of the PPA

directs the EPA to, among other things,

* * * review regulations of the Agency prior and subsequent to their

proposal to determine their effect on source reduction.

The EPA believes that these proposed standards are consistent with the

purpose of the Clean Air Act's requirement to consider source reduction

technologies. The EPA's emphasis on source reduction hierarchy is also

entirely consistent with the Act, particularly the air toxics provision

(section 112) that requires the maximum achievable emission reductions

through measures that

* * * reduce the volume of, or eliminate emissions of, such

pollutants through process changes, substitution of materials or

other modifications; * * *

In the proposed standards, the EPA has incorporated the application of

the environmental source reduction management hierarchy. These proposed

standards encourage source reduction by (1) control of HAP air

emissions through the use of condensers and vapor collection/recovery

systems and (2) allowing for the use of system optimization on glycol

dehydration units through the adjustment of the glycol circulation

rate. This adjustment may significantly reduce related HAP emissions

because, on average, the glycol circulation rate is double the

necessary rate.

D. Relationship of Proposed Standards to the Natural Gas STAR Program

The Natural Gas STAR Program is a voluntary, cooperative program

between the EPA and the natural gas industry to promote cost-effective

methods for reducing methane emissions. The program, part of the U.S.

Climate Change Action Plan, outlines a set of initiatives that will

enable the profitable reduction of greenhouse gas emissions. The first

phase of the program was initiated in 1993 with companies in the

natural gas transmission and distribution industry. The 38 partner

companies are currently capturing 36.8 million m\3\ (1.3 billion ft\3\

(bcf)) of methane annually, worth almost $3 million.

The natural gas production industry program was initiated in 1995.

When fully implemented in the year 2000, Natural Gas STAR companies are

projected to recover more than 710 million m\3\ (25 bcf) of methane

annually, worth an estimated $50 million.

Under this program, partners agree to implement two best management

practices (BMPs) when cost-effective. These include (1) identifying and

replacing high-bleed pneumatic devices and (2) installing GCG

separators (flash tank separators) on glycol dehydration units and

recovering the separated methane stream. Additionally, the EPA has

agreed to assist partner companies in the removal of unjustified

regulatory barriers to implementing these practices.

The standards proposed for the oil and natural gas production and

natural gas transmission and storage source categories do not create

regulatory barriers to implementing the BMPs encouraged under this

program. The control requirements for glycol dehydration units at major

sources and selected area sources would require control of the flash

tank separator vent, if present. This would encourage further product

recovery and reduction of HAP and methane air emissions and enhance the

product recovery and emission reduction goals of the Natural Gas STAR

Program.

E. Overlapping Regulations

The proposed standards clarify the applicability of 40 CFR part 63,

subpart HH (oil and natural gas production NESHAP) equipment leak

provisions by stating that existing oil and natural gas production

sources subject to subpart HH and 40 CFR part 60, subpart KKK (onshore

natural gas processing plants NSPS) are required only to comply with

subpart KKK.

[[Page 6309]]

X. Solicitation of Comments

Comments are specifically requested on several aspects of the

proposed standards. These topics are summarized below.

A. Potential-to-Emit

The EPA is currently in the process of developing a separate

rulemaking to address several potential-to-emit (PTE) issues. Until the

EPA takes final action on the proposal, any determination of PTE made

to determine a facility's applicability status under a relevant part 63

standard should be made according to requirements set forth in the

relevant standard and in the General Provisions.

Industry representatives have commented that both oil and natural

gas production and natural gas transmission and storage facilities

often have a maximum capacity (based on physical and operational

design) to emit higher than inherent physical limitations would allow.

Concern was expressed that potential emissions could be overestimated

and a facility could be subject to the Act requirements affecting major

sources despite inherent limitations (e.g., depletion of oil and

natural gas reservoirs).

The EPA is committed to providing technical assistance on the type

of inherent physical and operational design features that may be

considered acceptable in determining the PTE for certain source

categories. Therefore, the EPA is evaluating and solicits specific

recommendations, along with supporting documentation, on how inherent

limitations should be addressed for oil and natural gas production and

natural gas transmission and storage facilities.

B. Definition of Facility

The EPA specifically requests comments on the proposed definition

of facility. Specifically, the EPA requests comments on whether the

proposed definition appropriately implements the intent of the major

source definition in section 112(a)(1) for the oil and natural gas

production and natural gas transmission and storage source categories,

or if another definition would better implement this intent.

C. Interpretation of ``Associated Equipment'' in Section 112(n)(4) of

the Act

As discussed in section V of this preamble, the EPA has proposed a

definition for the term ``associated equipment'' to implement the

special provisions of section 112(n)(4) of the Act for the oil and

natural gas production source category. Comments are specifically

requested on the EPA's proposed definition.

If there is disagreement with the EPA's proposed definition, the

EPA requests that the commenter provide alternative definition options,

along with supporting documentation, that would provide the relief

intended by Congress for this industry while preserving the EPA's

ability to regulate HAP emissions from glycol dehydration units,

storage vessels with flash emissions, and equipment leaks.

D. Regulation of Area Source Glycol Dehydration Units

The EPA does not intend to regulate TEG dehydration units that have

low HAP emissions or units in areas where there is little or no

potential threat of adverse health effects from exposure to HAP

emissions from TEG dehydration units. The rules, as proposed, include

applicability cutoffs of (1) 85 thousand m\3\/day (3.0 MMSCF/D) of flow

to the unit, on an annual average basis, or (2) 0.9 Mg/yr (1 tpy) of

benzene emissions.

The EPA is proposing an additional action level based on the

county-level urban versus rural location of area source TEG dehydration

units. Thus, only those selected area source TEG dehydration units

located in counties classified as urban (see section III of this

preamble) and also meeting or exceeding the actual natural gas

throughput and benzene emission rate action levels will be required to

install air emission controls on all process vents. Units (1) below

these cutoffs or (2) located in counties classified as rural would not

have to be controlled for HAP emissions under the proposed rules.

The EPA evaluated the use of a risk-distance applicability criteria

as an alternative to the urban area criteria. The EPA is requesting

comment, along with supporting documentation, on the use of a risk-

distance applicability criteria for focussing the area source

provisions of this proposed regulation to only those area source TEG

dehydration units that meet a risk-distance criteria for applicability.

TEG dehydration units located at natural gas transmission and

storage facilities emit similar emissions and have a similar emission

potential to those located at oil and natural gas production

facilities. However, insufficient information was available to conduct

an area source finding analysis for the natural gas transmission and

storage source category.

The EPA is currently evaluating whether TEG dehydration units

located at natural gas transmission and storage area sources result in

an unacceptable risk and should be listed and regulated as an area

source. The EPA is soliciting comment, along with supporting

documentation, in this notice on the emissions, location, and number of

TEG dehydration units located at natural gas transmission and storage

area sources. Information supplied to the EPA should either support or

negate the need for an area source listing.

E. HAP Emission Points

The EPA specifically requests information on potential HAP

emissions that may be associated with (1) process vents at amine

treating units and sulfur plants, (2) transfer and storage of pipeline

pigging wastes, and (3) combustion sources located at oil and natural

gas production and natural gas transmission and storage facilities. The

EPA has not identified sufficient data to adequately address the

potential of HAP emissions from these emission points in these source

categories. Thus, the EPA is requesting comment, along with supporting

documentation, on HAP emissions from these emission points.

F. Storage Vessels at Natural Gas Transmission and Storage Facilities

The EPA had insufficient information to determine whether

significant HAP-emitting storage vessels warranting control are located

at natural gas transmission and storage facilities that are major

sources of HAP. Therefore, the EPA is soliciting information and

comment, along with supporting documentation, regarding the storage

vessels located at these sources.

Specifically, the EPA is requesting information and comment, along

with supporting documentation, on whether the storage vessels currently

being proposed for control under the oil and natural gas production

NESHAP are similar to those located at natural gas transmission and

storage facilities.

G. Cost Impact and Production Recovery Credits

The EPA specifically requests comments on the cost impact and the

production recovery credits as discussed in section IV of the preamble.

In addition to its solicitation for comments, the EPA also requests

documentation to support cost impact or recovery credit comments.

XI. Administrative Requirements

A. Docket

The docket for these rulemakings is A-94-04. The docket is an

organized and complete file of all the information considered by the

EPA in the development of this rulemaking. The principal purposes of

the docket are (1) to allow interested parties a means to

[[Page 6310]]

identify and locate documents so that they can effectively participate

in the rulemaking process and (2) to serve as the record in case of

judicial review (except for interagency review materials) [section

307(d)(7)(A) of the Act]. This docket contains copies of the regulatory

text, BID, BID references, and technical memoranda documenting the

information considered by the EPA in the development of the proposed

rules. The docket is available for public inspection at the EPA's Air

and Radiation Docket and Information Center, the location of which is

given in the ADDRESSES section of this notice.

B. Paperwork Reduction Act

The information collection requirements in these proposed rules

have been submitted for approval to the Office of Management and Budget

(OMB) under the Paperwork Reduction Act, 44 U.S.C. 3501 et seq.

Information Collection Request (ICR) documents have been prepared by

the EPA (ICR Nos. 1788.01 and 1789.01) and copies may be obtained from

Sandy Farmer, OPPE Regulatory Information Division; U.S. Environmental

Protection Agency (2137); 401 M Street, S.W.; Washington, DC 20460 or

by calling (202) 260-2740.

Information is required to ensure compliance with the provisions of

the proposed rules. If the relevant information were collected less

frequently, the EPA would not be reasonably assured that a source is in

compliance with the proposed rules. In addition, the EPA's authority to

take administrative action would be reduced significantly.

The proposed rules would require that facility owners or operators

retain records for a period of five years, which exceeds the three year

retention period contained in the guidelines in 5 CFR 1320.6. The five

year retention period is consistent with the provisions of the General

Provisions of 40 CFR Part 63, and with the five year records retention

requirement in the operating permit program under Title V of the CAA.

All information submitted to the EPA for which a claim of

confidentiality is made will be safeguarded according to the EPA

policies set forth in Title 40, Chapter 1, Part 2, Subpart B,

Confidentiality of Business Information. See 40 CFR 2; 41 FR 36902,

September 1, 1976; amended by 43 FR 3999, September 8, 1978; 43 FR

42251, September 28, 1978; and 44 FR 17674, March 23, 1979. Even where

the EPA has determined that data received in response to an ICR is

eligible for confidential treatment under 40 CFR Part 2, Subpart B, the

EPA may nonetheless disclose the information if it is ``relevant in any

proceeding'' under the statute [42 U.S.C. 7414(C); 40 CFR 2.301(g)].

The information collection complies with the Privacy Act of 1974 and

Office of Management and Budget (OMB) Circular 108.

Information to be reported consists of emission data and other

information that are not of a sensitive nature. No sensitive personal

or proprietary data are being collected.

The estimated annual average hour burden for the major source

provisions of the proposed oil and natural gas production NESHAP is 169

hours per respondent. The estimated annual average cost of this burden

is $7,300 for each of the estimated 484 existing and new (projected)

respondents.

The estimated annual average hour burden for the area source

provisions of the proposed oil and natural gas production NESHAP is 56

hours per respondent. The estimated annual average cost of this burden

is $2,400 for each of the estimated 572 existing and new (projected)

respondents.

The estimated annual average hour burden for the major source

provisions of the proposed natural gas transmission and storage NESHAP

is 77 hours per respondent. The estimated annual average cost of this

burden is $3,300 for each of the estimated 5 existing respondents.

Reports are required on a semi-annual and annual basis (depending

upon the reports) and as required, as in the case of startup, shutdown,

and malfunction plans. Burden means the total time, effort, or

financial resources expended by persons to generate, maintain, retain,

or disclose or provide information to or for a Federal agency. This

includes the time needed to review instructions; develop, acquire,

install, and utilize technology and systems for the purposes of

collecting, validating, and verifying information, processing and

maintaining information, and disclosing and providing information;

adjust the existing ways to comply with any previously applicable

instructions and requirements; train personnel to be able to respond to

a collection of information; search data sources; complete and review

the collection of information; and transmit or otherwise disclose the

information.

An Agency may not conduct or sponsor, and a person is not required

to respond to a collection of information unless it displays a

currently valid OMB control number. The OMB control numbers for the

EPA's regulations are listed in 40 CFR part 9 and 48 CFR Chapter 15.

Comments are requested on the EPA's need for this information, the

accuracy of the provided burden estimates, and any suggested methods

for minimizing respondent burden, including through the use of

automated collection techniques. Send comments on the ICRs to the

Director, OPPE Regulatory Information Division; U.S. Environmental

Protection Agency (2137); 401 M Street, S.W., Washington, DC 20460; and

to the Office of Information and Regulatory Affairs, Office of

Management and Budget, 725 17th Street, N.W., Washington, DC 20503,

marked ``Attention: Desk Officer for EPA.'' Include the ICR number(s)

in any correspondence. Since OMB is required to make a decision

concerning the ICR's between 30 and 60 days after February 6, 1998, a

comment to OMB is best assured of having its full effect if OMB

receives it by March 9, 1998. The final rules will respond to any OMB

or public comments on the information collection requirements contained

in this proposal.

C. Executive Order 12866

Under Executive Order 12866 [58 FR 5173 (October 4, 1993)], the EPA

must determine whether the regulatory action is ``significant'' and

therefore subject to OMB review and the requirements of the Executive

Order. The criteria set forth in section 1 of the Order for determining

whether a regulation is a significant rule are as follows: (1) Is

likely to have an annual effect on the economy of $100 million or more,

or adversely and materially affect a sector of the economy,

productivity, competition, jobs, the environment, public health or

safety, or State, local or tribal governments or communities; (2) is

likely to create a serious inconsistency or otherwise interfere with an

action taken or planned by another agency; (3) is likely to materially

alter the budgetary impact of entitlements, grants, user fees or loan

programs, or the rights and obligations of recipients thereof; or (4)

is likely to raise novel legal or policy issues arising out of legal

mandates, the President's priorities, or the principles set forth in

the Executive Order.

Based on criteria 1, 2, and 3, this action is not a ``significant

regulatory action'' within the meaning of Executive Order 12866.

However, the OMB has deemed it significant under criterion 4 and has

requested review of this proposed rulemaking package. Therefore, the

EPA submitted this action to OMB for review. Changes made in response

to OMB suggestions or recommendations are documented in the public

record.

[[Page 6311]]

D. Regulatory Flexibility

The Regulatory Flexibility Act (RFA) generally requires an agency

to conduct a regulatory flexibility analysis of any rule subject to

notice and comment rulemaking requirements, unless the agency certifies

that the rule will not have a significant economic impact on a

substantial number of small entities. Small entities include small

businesses, small not-for-profit enterprises, and small governmental

jurisdictions. These proposed rules will not have a significant

economic impact on a substantial number of small entities. According to

Wards Business Directory (1993), there are 1,152 firms in the seven

affected Standard Industrial Classification (SIC) codes and 735 of

these firms meet the Small Business Administration (SBA) definition of

a small entity.

The number of affected small entities for these rules is likely to

be minimal due to several considerations in these rules that minimize

the burden on all firms, both small and large. These considerations

include exempting from control requirements those glycol dehydration

units located at major or area sources with (1) an actual flowrate of

natural gas to the glycol dehydration unit less than 85 m\3\/day (3.0

MMSCF/D), on an annual average basis, or (2) benzene emissions less

than 0.9 Mg/yr (1 tpy). In addition, emission controls are limited to

those area source glycol dehydration units located in urban areas.

In a screening of potential impacts on a sample of small entities,

the EPA found that there are minimal impacts on these entities. The

weighted average of control costs as a percent of sales is 0.09 of one

percent for the small firms in the sample, while a maximum value of 1.1

percent results for only two of these firms. The analysis also

indicates that with the regulations, the change in measures of

profitability are minimal (i.e., 0.11 of one percent change in the

cost-to-sales ratio for small firms), and there are no indications of

financial failures or employment losses for both small and large firms.

The screening analysis for these rules is detailed in the Economic

Impact Analysis (see Docket No. A-94-04).

Therefore, I certify that this action will not have a significant

economic impact on a substantial number of small entities.

E. Unfunded Mandates

Title II of the Unfunded Mandate Reform Act of 1995 (UMRA), Public

Law 104-4, establishes requirements for Federal agencies to assess the

effects of their regulatory actions on State, local, and tribal

governments and the private sector. Under section 202 of the UMRA, the

EPA generally must prepare a written statement, including a cost-

benefit analysis, for the proposed and final rules with ``Federal

mandates'' that may result in expenditures to State, local, and tribal

governments, in the aggregate, or to the private sector, of $100

million or more in any one year. Before promulgating an EPA rule for

which a written statement is needed, section 205 of the UMRA generally

requires the EPA to identify and consider a reasonable number of

regulatory alternatives and adopt the least costly, most cost-

effective, or least burdensome alternative that achieves the objectives

of the rule. The provisions of section 205 do not apply when they are

inconsistent with applicable law. Moreover, section 205 allows the EPA

to adopt an alternative other than the least costly, most cost-

effective, or least burdensome alternative if the Administrator

publishes with the final rule an explanation why that alternative was

not adopted. Before the EPA establishes any regulatory requirements

that may significantly or uniquely affect small governments, including

tribal governments, it must have developed under section 203 of the

UMRA a small government agency plan. The plan must provide for

notifying potentially affected small governments, enabling officials of

affected small governments to have meaningful and timely input in the

development of the EPA regulatory proposals with significant Federal

intergovernmental mandates, and informing, educating, and advising

small governments on compliance with the regulatory requirements.

The EPA has determined that these rules do not contain a Federal

mandate that may result in expenditures of $100 million or more for

State, local, and tribal governments, in the aggregate or the private

sector in any one year. The EPA's total estimated annual net costs of

the proposed rules is $10 million, including MIRR costs. Thus, today's

rules are not subject to the requirements of sections 202 and 205 of

the UMRA.

The EPA has determined that these rules contain no regulatory

requirements that might significantly or uniquely affect small

governments. No small government entities have been identified that

have involvement with these source categories and, as such, are not

covered by the regulatory requirements of the proposed regulations.

List of Subjects in 40 CFR Part 63

Environmental protection, Air pollution control, Air emissions

control, Associated equipment, Black oil, Condensate, Custody transfer,

Equipment leaks, Glycol dehydration units, Hazardous air pollutants,

Hazardous substances, Natural gas, Intergovernmental relations, Natural

gas processing plants, Natural gas transmission and storage, Oil and

natural gas production, Pipelines, Organic liquids distribution (non-

gasoline), Reporting and recordkeeping requirements, Storage vessels,

Tank batteries, Tanks, Triethylene glycol.

Dated: November 24, 1997.

Carol M. Browner,

Administrator.

For the reasons set out in the preamble, title 40, chapter I, part

63 of the Code of Federal Regulations is proposed to be amended as

follows:

PART 63--NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS

FOR SOURCE CATEGORIES

1. The authority citation for part 63 continues to read as follows:

Authority: 42 U.S.C. 7401 et seq.

2. Part 63 is amended by adding subpart HH to read as follows:

Subpart HH--National Emission Standards for Hazardous Air

Pollutants From Oil and Natural Gas Production Facilities

Sec.

63.760 Applicability and designation of affected source.

63.761 Definitions.

63.762 [Reserved]

63.763 [Reserved]

63.764 General standards.

63.765 Glycol dehydration unit process vent standards.

63.766 Storage vessel standards.

63.767 [Reserved]

63.768 [Reserved]

63.769 Equipment leak standards.

63.770 [Reserved]

63.771 Control requirements.

63.772 Test methods and compliance procedures.

63.773 Inspection and monitoring requirements.

63.774 Recordkeeping requirements.

63.775 Reporting requirements.

63.776 Delegation of authority. [Reserved]

63.777 Alternative means of emission limitation.

63.778 [Reserved]

63.779 [Reserved]

Table 1 to Subpart HH--List of Air Pollutants for Subpart HH

Table 2 to Subpart HH--Applicability of 40 CFR Part 63 General

Provisions to Subpart HH

[[Page 6312]]

Subpart HH--National Emission Standards for Hazardous Air

Pollutants From Oil and Natural Gas Production Facilities

Sec. 63.760 Applicability and designation of affected source.

(a) This subpart applies to the owners or operators of emission