DEPARTMENT OF AGRICULTURE

Grain Inspection, Packers and Stockyards Administration

7 CFR Part 801

RIN 0580-AA60

Tolerances for Moisture Meters

AGENCY: Grain Inspection, Packers and Stockyards Administration, USDA.

ACTION: Interim rule with request for comments.

-----------------------------------------------------------------------

SUMMARY: The Grain Inspection, Packers and Stockyards Administration

(GIPSA) is amending regulations under the United States Grain Standards

Act (USGSA) by revising tolerances for moisture meters used in official

grain inspection services. GIPSA is making this revision to reflect

tolerances for both the current official moisture meter, the Motomco

Model 919, and the Dickey-john GAC 2100, which will be phased in as the

new official moisture meter beginning on August 1, 1998.

DATES: This interim rule is effective August 1, 1998. To be assured of

consideration, written comments must be filed before August 24, 1998.

ADDRESSES: Written comments must be sent to Sharon Vassiliades, GIPSA,

USDA, STOP 3649, Washington, D.C. 20250-3649; FAX to (202) 720-4628; or

e-mail [email protected].

All comments received will be made available for public inspection

in Room 0623, USDA South Building, 1400 Independence Avenue, SW,

Washington, D.C., during business hours (7 CFR 1.27(b)).

FOR FURTHER INFORMATION CONTACT: Sharon Vassiliades, address as above,

telephone (202) 720-1738.

SUPPLEMENTARY INFORMATION:

Executive Order 12866

This interim rule has been determined to be not significant for

purposes of Executive Order 12866 and, therefore, has not been reviewed

by OMB.

Executive Order 12988

This interim rule has been reviewed under Executive Order 12988,

Civil Justice Reform. This action is not intended to have a retroactive

effect. The Act provides in section 87g that no State or subdivision

may require or impose any requirements or restrictions concerning the

inspection, weighing, or description of grain under the Act. Otherwise,

this rule will not preempt any State or local laws, regulations, or

policies, unless they present an irreconcilable conflict with this

rule. There are no administrative procedures which must be exhausted

prior to any judicial challenge to the provisions of this rule.

Effect on Small Entities

The Administrator of GIPSA certifies that this rule will not have a

significant impact on a substantial number of small entities as defined

in the Regulatory Flexibility Act (5 U.S.C. 601). GIPSA is making this

revision to reflect tolerances for the current official moisture meter,

the Motomco Model 919, and the Dickey-john GAC 2100, which is being

phased in as the new official moisture meter beginning on August 1,

1998. The revised tolerances will be applied to moisture meters owned

and used by GIPSA, 8 delegated States, and the 57 official agencies (49

private entities and 8 State agencies) to perform official grain

inspection services. Most of these agencies would be considered small

entities under Small Business Administration criteria. Although the

check testing procedure for the new meter is simpler than that for the

current meter, the tolerance on the new moisture meter used for

official inspection is being neither tightened nor relaxed as compared

to the tolerances for the current meter. There is, therefore, little

impact of making these tolerance changes in the regulations on small or

large entities engaged in the inspection of grain.

Information Collection and Recordkeeping Requirements.

In accordance with the Paperwork Reduction Act of 1995, the

recordkeeping and reporting burden imposed by Part 801 was previously

approved by OMB under control number 0580-0013 and will not be affected

by this rule.

Background

GIPSA has selected a new official moisture meter for the national

grain inspection system. This was announced in the Federal Register on

April 9, 1998 (63 FR 17356). In a separate notice document published in

the Federal Register on this date, GIPSA announces that as of August 1,

1998, all official moisture content measurements of corn, soybeans, and

sunflower seed inspected under the USGSA will be made with the GAC

2100. Transition dates for other grains will be announced separately at

a later time. Use of the new instruments for official moisture

measurements will be phased in over a 2-year period. The maintenance

tolerances for moisture meters are stated for low, mid, and high

moisture ranges for both direct comparison and sample exchange testing.

These tolerances have been and will continue to be applied to the

Motomco 919 moisture meters used for official inspection until such

time as they are replaced by the GAC 2100.

Differences in technology between the GAC 2100 and the Motomco 919

have necessitated the development of a new procedure for checking the

performance of individual GAC 2100 meters against standard meters to

determine whether they are in tolerance. The current three moisture

range tolerances and the direct comparison method for checking meters,

other than Headquarters meters, used for the Motomco 919 will not be

needed to determine if the GAC 2100 meters are in tolerance. The

current mid range moisture tolerance for Headquarters, and all other

than Headquarters meters, will be used to determine if the GAC 2100 is

within tolerance. Further, for the meters other than Headquarters, only

the sample exchange method will be used.

Pursuant to 5 U.S.C. 553, it is found and determined upon good

cause that it is impracticable, unnecessary, and contrary to the public

interest to give preliminary notice prior to putting this rule into

effect and that good cause exists for not postponing the effective date

of this rule until 30 days after publication in the Federal Register

because: (1) the tolerance for the new moisture meter is being neither

tightened nor relaxed as compared to the tolerance for the current

meter; (2) the 1999 grain market year begins August 1, 1998, and the

changes should be in effect to allow the use of the new moisture meter

at the beginning of the marketing year for corn, soybeans and sunflower

seed; (3) this rule provides a 60-day opportunity for comment, and all

written comments timely received will be considered prior to

finalization of the rule.

List of Subjects in 7 CFR Part 801

Grains, Scientific equipment.

For reasons set forth in the preamble, 7 CFR Part 801 is amended as

follows:

1. The authority citation for Part 801 continues to read as

follows:

Authority: Pub. L. 94-582, 90 Stat 2867, as amended (7 U.S.C. 71

et seq.).

2. Section 801.6 is revised to read as follows:

Sec. 801.6 Tolerances for moisture meters.

(a) The maintenance tolerances for Motomco 919 moisture meters used

in performing official inspection services shall be:

(1) Headquarters standard meters:

[[Page 34555]]

------------------------------------------------------------------------

Tolerance

Moisture range ------------------------------------------------

Direct comparison Sample exchange

------------------------------------------------------------------------

Low.................... 0.05

percent moisture, mean

deviation from

National standard

moisture meter using

Hard Red Winter wheat

Mid.................... 0.05

percent moisture, mean

deviation from

National standard

moisture meter using

Hard Red Winter wheat

High................... 0.05

percent moisture, mean

deviation from

National standard

moisture meter using

Hard Red Winter wheat

------------------------------------------------------------------------

(2) All other than Headquarters standard meters:

------------------------------------------------------------------------

Tolerance

Moisture range ------------------------------------------------

Direct comparison Sample exchange

------------------------------------------------------------------------

Low.................... 0.15 0.20

percent moisture, mean percent moisture,

deviation from mean deviation from

standard moisture standard moisture

meter using Hard Red meter using Hard Red

Winter wheat Winter wheat.

Mid.................... 0.10 0.15

percent moisture, mean percent moisture,

deviation from mean deviation from

standard moisture standard moisture

meter using Hard Red meter using Hard Red

Winter wheat Winter wheat.

High................... 0.15 0.20

percent moisture, mean percent moisture,

deviation from mean deviation from

standard moisture standard moisture

meter using Hard Red meter using Hard Red

Winter wheat Winter wheat.

------------------------------------------------------------------------

(b) The maintenance tolerances for GAC 2100 moisture meters used in

performing official inspection services shall be:

(1) Headquarters standard meters. By direct comparison using mid-

range Hard Red Winter wheat, 0.05% mean deviation for the

average of the Headquarters standard moisture meters.

(2) All other than Headquarters standard meters. By sample exchange

using mid-range Hard Red Winter wheat, 0.15% mean

deviation from the standard meter.

Dated: June 19, 1998.

David R. Shipman,

Acting Administrator, Grain Inspection, Packers and Stockyards

Administration.

[FR Doc. 98-16964 Filed 6-24-98; 8:45 am]