Energy Conservation Program for Consumer Products: Proposed Rule Adding Test Procedures for Externally Vented Refrigerators and Refrigerator-Freezers
Federal RegisterApr 8, 1997
Ask Donna
What actually matters in this document.
Text
DEPARTMENT OF ENERGY
Office of Energy Efficiency and Renewable Energy
10 CFR Part 430
RIN No. 1904-AA93
Energy Conservation Program for Consumer Products: Proposed Rule
Adding Test Procedures for Externally Vented Refrigerators and
Refrigerator-Freezers
AGENCY: Office of Energy Efficiency and Renewable Energy, Department of
Energy.
ACTION: Proposed rule.
-----------------------------------------------------------------------
SUMMARY: The Department of Energy (Department or DOE) proposes test
procedures for measuring the energy consumption of an externally vented
refrigerator and externally vented refrigerator-freezer, a
technological innovation which is not accommodated by the existing test
procedures. Today's proposal would not change in any way the test
procedures applicable to refrigerator and refrigerator-freezer designs
without venting.
DATES: Written comments in response to this notice must be received by
May 8, 1997. The Department requests 10 copies of the comments and, if
possible, a computer disk. The Department is currently using
WordPerfectTM 6.1.
ADDRESSES: Written comments are to be submitted to: U.S. Department of
Energy, Office of Energy Efficiency and Renewable Energy, EE-43, Room
1J-018, ``Test Procedures for Refrigerators and Refrigerator-
Freezers,'' Docket No. EE-RM-97-118, Forrestal Building, 1000
Independence Avenue, SW, Washington, DC 20585-0121. Telephone: (202)
586-7574. Comments may be hand delivered between the hours of 8:00 a.m.
and 4:00 p.m., Monday through Friday, except Federal holidays. Comments
should be labeled, ``Test Procedures for Refrigerators and
Refrigerator-Freezers'' (Docket No. EE-RM-97-118), both on the document
or computer disk and on the envelope. Copies of public comments
received may be read and/or photocopied at the Department of Energy
Freedom of Information Reading Room, U.S. Department of Energy,
Forrestal Building, Room 1E-190, 1000 Independence Avenue, SW,
Washington, D.C. 20585-0121, telephone (202) 586-6020, between the
hours of 9:00 a.m. and 4:00 p.m., Monday through Friday, except Federal
holidays.
FOR FURTHER INFORMATION CONTACT:
Michael G. Raymond, U.S. Department of Energy, Energy Efficiency and
Renewable Energy, Mail Station EE-43, Forrestal Building, 1000
Independence Avenue, SW, Washington, D.C., 20585-0121, (202) 586-9611
Eugene Margolis, Esq., U.S. Department of Energy, Office of General
Counsel, Mail Station GC-72, Forrestal Building, 1000 Independence
Avenue, SW, Washington, D.C. 20585-0103, (202) 586-9507
SUPPLEMENTARY INFORMATION:
I. Introduction
A. Authority
Part B of Title III of the Energy Policy and Conservation Act of
1975, Public Law 94-163, as amended by the National Energy Conservation
Policy Act, Public Law 95-619, the National Appliance Energy
Conservation Act of 1987, Public Law 100-12, the National Appliance
Energy Conservation Amendments of 1988, Public Law 100-357, and the
Energy Policy Act of 1992, Public Law 102-486, created the Energy
Conservation Program for Consumer Products other than Automobiles
(Program).1 The products currently subject to this Program (often
referred to hereafter as ``covered products'') include electric
refrigerators and electric refrigerator-freezers.
---------------------------------------------------------------------------
\1 \ Part B of Title III of Energy Policy and Conservation Act,
as amended, is referred to in this proposed rule as ``EPCA'' or the
``Act.'' Part B of Title III is codified at 42 U.S.C. 6291-6309.
---------------------------------------------------------------------------
Under the Act, the Program consists essentially of three parts:
testing, labeling, and the Federal energy conservation standards. This
proposed rule concerns the testing aspect of this program. The
Department, with assistance from the National Institute of Standards
and Technology, may amend or establish new test procedures, as
appropriate, for any covered product. EPCA, Sec. 323. The purpose of
the test procedures is to produce test results that measure energy
efficiency, energy use, water use (in the case of showerheads, faucets,
water closets and urinals), or estimated annual operating cost of a
covered product during a representative average use cycle or period of
use. The test procedures shall not be unduly burdensome to conduct.
EPCA, Sec. 323(b)(3). One hundred and eighty days after a test
procedure for a product is adopted, no manufacturer may make
representations with respect to energy use, efficiency or water use of
such product, or the cost of energy consumed by such product, except as
reflected in tests conducted according to the DOE procedure. EPCA,
Sec. 323(c)(2).
Test procedures promulgated by DOE appear at 10 CFR Part 430,
Subpart B. The ``Uniform Test Method for Measuring the Energy
Consumption of Electric Refrigerators and Electric Refrigerator-
Freezers'' appears at Appendix A1 to Subpart B.
Section 323(e) of the Act requires DOE to determine to what extent,
if any, a proposed test procedure would alter the measured energy
efficiency, measured energy use or measured water use of any covered
product as determined under the existing test procedure. If DOE
determines that an amended test procedure would alter the measured
efficiency or measured use of a covered product, DOE is required to
amend the applicable energy conservation standard accordingly. In
determining the amended energy conservation standard, DOE is required
to measure the energy efficiency or energy use of a representative
sample of covered products that minimally comply with the existing
standard. The average energy use of this representative sample,
determined under the amended test procedure, constitutes the amended
standard. EPCA, Sec. 323(e)(2).
B. Background
Today's notice proposes to add test procedure amendments that are
specific to a new product design--externally vented refrigerators and
externally vented refrigerator-freezers. These test procedure
amendments will apply only to this product design and will not apply to
existing product designs of refrigerators and refrigerator-freezers
without this feature. Existing test procedures for non-externally
vented refrigerators and refrigerator-freezers will remain unchanged.
The energy conservation standards for refrigerators and refrigerator-
freezers will be unaffected by the adoption or use of the proposed new
test procedures.
The Department does not believe that any of the proposed changes to
the test procedures would alter the measurement of energy consumption
of electric refrigerators and refrigerator-freezers currently on the
market. Accordingly, adoption of the proposed amended test procedures
would not require any change in energy conservation standards for
refrigerators and refrigerator-freezers currently in place. In
addition, the Department believes that the proposed test procedure
amendments would have no effect on the pending rulemaking considering
revised minimum energy conservation standards for electric
[[Page 16740]]
refrigerators, refrigerator-freezers and freezers. (Docket No. EE-RM-
93-801).
On March 14, 1995, Edward Schulak Equities, Inc. (``ESE'')
submitted a letter to the Department regarding the inapplicability of
existing test procedures in Appendix A1 to externally vented
refrigerators. ESE submitted a description of an externally vented
refrigerator from a recently granted patent. ESE claimed that allowing
cooler outside air to be passed over the condenser/compressor of a
refrigerator would reduce energy consumption of the refrigerator. ESE
explained that the existing test procedures address only a closed
system without the possibility of transfer of exterior air cooler than
the ambient room temperature. Based on the information submitted, the
Department agrees that the existing test procedures do not permit the
measurement of energy consumption of an externally vented refrigerator.
While ESE's letter was submitted as a petition for waiver, the
Department concluded that its waiver process was not appropriate
because waivers apply to ``basic models,'' and no models are currently
being manufactured incorporating this invention, nor is the invention
being produced for retrofitting. Therefore, the Department published
ESE's letter and issued a Notice of Inquiry inviting public comment on
several issues relating to the energy consumption, manufacturability,
and retrofitting of externally vented refrigerators. 60 FR 37603 (July
21, 1995). The Department also invited comments on methods of testing
externally vented refrigerators and refrigerator-freezers to determine
energy savings. Notice of Inquiry at 60 FR 37604. No public comments
were received in response to this Notice of Inquiry.
On November 13, 1995, acting upon the Department's suggestion, ESE
submitted a draft of proposed amendments to the test procedures for
refrigerators and refrigerator-freezers. The Department referred this
submittal to the National Institute of Standards and Technology (NIST).
NIST, the Department and ESE representatives extensively discussed the
requirements for test procedures for externally vented refrigerators
and refrigerator-freezers. NIST conducted an analysis of test
procedures for externally vented refrigerators and refrigerator-
freezers. The notice published today by the Department reflects these
extensive discussions and subsequent NIST recommendations for test
procedure amendments.
Today's notice proposes revising the test procedures for electric
refrigerators and electric refrigerator-freezers appearing in 10 CFR
Part 430, Subpart B, Appendix A1 by: (1) Adding a definition of
externally vented refrigerators and refrigerator-freezers to which the
revisions are applicable, (2) prescribing test conditions for
externally vented refrigerators and refrigerator-freezers, (3)
specifying energy consumption measurement tests for externally vented
refrigerators and refrigerator-freezers, and (4) including calculation
methods for deriving results from test measurements.
II. Discussion
The current test procedures for refrigerators and refrigerator-
freezers, found at 10 CFR Part 430, Appendix A1 of Subpart B, does not
address testing of externally vented refrigerators and refrigerator-
freezers. The existing test procedures apply to a refrigerator system
to which cool outside air cannot be conducted for purposes of heat
transfer. Externally vented refrigerators would be designed to permit
outside air to be introduced across the refrigerator's condenser and
compressor and, in some cases, throughout the walls of the
refrigerator. The introduction of outside air at temperatures lower
than the ambient room air temperature permits more efficient heat
transfer, potentially resulting in energy savings.
The Department therefore proposes to revise the test procedures to
include provisions tailored to measuring the energy consumption of
externally vented refrigerators and refrigerator-freezers. These
provisions will add to, rather than replace, the existing test
procedures, which remain fully applicable to both externally vented and
non-vented refrigerators and refrigerator-freezers. The Department
emphasizes that the proposed amendments to the test procedures do not
affect in any way the test procedures applicable to existing
refrigerator designs. The amendments provide a method for accurately
measuring the energy consumption of an enclosed, externally vented
refrigerator or refrigerator-freezer unit and take account of design
features (e.g., enclosed condenser, outside air conduits, dampers)
peculiar to an externally vented refrigerator or refrigerator-freezer
that circulates outside air around its condenser. The amendments do not
apply to refrigerators or refrigerator-freezers that use outside air
through the refrigerator walls. With these amendments, the test
procedures will provide a basis for making comparable measurements of
energy consumption for externally vented and unvented refrigerators and
refrigerator-freezers.
The Department also emphasizes that recognition of a design option
of externally vented refrigerators and refrigerator-freezers does not
affect in any way the Department's consideration of design options in
connection with its consideration of proposed revisions to energy
consumption standards for refrigerators and refrigerator-freezers. This
design option was not included in the standards rulemaking record and
therefore cannot be considered in the current standards rulemaking.
The Department invites comments on any aspect of the proposed test
procedure amendments for externally vented refrigerators and
refrigerator-freezers.
The Department today proposes to amend the test procedures
applicable to electric refrigerators and electric refrigerator-freezers
(10 CFR Part 430, Subpart B, Appendix A1), as follows:
1. Definitions and applicability of amended test procedures. The
Department proposes to define ``externally vented refrigerator or
refrigerator-freezer'' as a refrigerator or refrigerator-freezer with
an enclosed condenser or an enclosed condenser/compressor compartment,
and a set of air ducts for transferring exterior air from outside the
building envelope into, through, and out of the refrigerator or
refrigerator-freezer cabinet (section 1.12). Energy consumption savings
from an externally vented refrigerator or refrigerator-freezer should
be achievable for outside air temperatures between 60 deg.F and 80
deg.F. Above 80 deg.F, outside air may be warmer than ambient room
air, making heat transfer in the wrong direction for energy savings.
Below 60 deg.F, outside air may be too cool for optimal operation of
the unit. The proposed amendments to the test procedures are generally
predicated upon a unit's design that permits the exclusion and/or
mixing of outside air that is either above 80 deg.F or below 60
deg.F. Accordingly, the amendments to the test procedures will apply
only under conditions where the externally vented refrigerator or
refrigerator-freezer design is capable of mixing the exterior air drawn
in from outside the building envelope with the ambient room air. The
modification includes thermostatically controlled dampers or controls
that: 1) enable the proper mixing of outside and ambient room air when
the outside air temperature is lower than 60 deg.F, and 2) exclude
outside air warmer than 80 deg.F, or warmer than room air temperature
(section 1.12). Externally vented units could have
[[Page 16741]]
temperature controls that exclude outside air either at a pre-set
temperature no lower than 80 deg.F or when the outside air temperature
exceeds the ambient room air temperature (section 1.12). The test
procedures require that prior to conducting energy consumption tests,
the operability of thermostatic controls be verified (section 5.4.1).
All tests must generally be conducted with the thermostatic controls
operable. A special rule is provided for testing energy consumption
when mixing controls do not operate properly (section 5.4.2.4). The
test procedures will take account of the energy consumption of any
exterior air fan that draws air to the refrigerator cabinet.
2. Exterior air source. The Department recognizes that actual
testing should take place under conditions of variable exterior air
temperatures and, therefore, proposes to require that prescribed test
conditions include the provision of an external air source that
provides air at adjustable temperature and pressure capabilities
(section 2.6). The test procedures prescribe the location of
temperature sensors for measuring the air temperature at the inlet to
the condenser/compressor compartment (section 2.6.2). Air temperature
will also be measured at the exterior air source. Temperature
measurements are to be made at prescribed intervals.
3. Air ducts. Externally vented refrigerators and refrigerator/
freezers depend upon air ducts to transfer exterior air to the
refrigerator cabinet. Rather than specifying the length, diameter,
shape and material of the duct, the Department proposes to specify air
pressure requirements as a uniform test condition (section 2.6.3).
Specifically, the proposed test procedures require exterior air
pressure at the inlet to the refrigerator unit to be maintained at a
negative pressure of 0.20'' 0.05'' water column (62 Pa
12.5 Pa). The test procedures also specify location
distances for the pressure sensors, relative to the exterior air source
(i.e., the inlet to the building envelope) and to the condenser inlet.
4. Applicability of general test method conditions. The proposed
amendments to the test procedures are not intended to supplant existing
test methods applicable to all other refrigerators and refrigerator-
freezers. Accordingly, the proposed amendments provide that, except as
expressly modified, the test conditions and specifications included in
the existing test procedures shall also apply to externally vented
refrigerators and refrigerator-freezers (section 5.4).
5. Energy consumption correction factor for test measurements. The
Department proposes a series of formulas for determining energy
consumption from test measurements. First, the Department recognizes
that energy consumption of any refrigerator will be different with and
without door openings. Under the existing test procedure, refrigerators
are tested at 90 deg.F without door openings to simulate the energy
consumption they would have at normal room temperature with door
openings. Normal room temperature for the refrigerator test procedure
is considered to be 80 deg.F, the typical temperature of the ambient
air surrounding the refrigerator's condenser. An externally vented
refrigerator will show an artificially low energy consumption compared
to an unvented refrigerator when tested at 90 deg.F room air
temperature, because 90 deg.F is warmer than normal room temperature.
The Department proposes to require calculation of a correction factor
for each basic model of externally vented refrigerator. The correction
factor is the ratio of the energy consumption of an externally vented
refrigerator (with external venting disabled) at 90 deg.F inlet air
temperature to the energy consumption of the unit at 80 deg.F inlet
air temperature (sections 5.4.2.1 and 6.3.1).
6. Energy consumption test measurements and calculations. Based on
analysis by NIST and its derivation of an algebraic equation for
determining energy consumption over a range of outside air
temperatures, the Department has determined that test measurements of
energy consumption need be taken at only two outside air temperatures,
90 deg.F and 60 deg.F (sections 5.4.2.2 and 5.4.2.3). If the outside
air temperature is not in this range, mixing controls and dampers will
keep the condenser inlet temperature within the range. Accordingly, the
Department proposes an energy profile equation that will allow for the
interpolation of energy consumption at outside air temperatures within
this range (section 6.3.4). The parameters of the energy profile
equation are determined for each basic model of externally vented
refrigerator that is tested, based on the measured energy consumption
during testing at 90 deg.F and 60 deg.F.
Once the parameters of the energy profile equation are determined,
the test procedures provide a basis for calculating energy consumption
at various temperatures. Because temperatures vary across the country,
throughout a day, and throughout the year, the proposed test procedures
specify an energy consumption formula that determines a unit's total
energy consumption based on weighted averaging of the unit's energy
consumption at different exterior air temperatures. The test procedures
provide weighting factors for a national average energy consumption
(section 6.3.6) and weighting factors for four different regions of the
country, which are identified on a map. This procedure was based on the
test procedure for heat pumps, for which energy savings are also a
function of climate. The regional map is the same as that used in the
heat pump test procedure, except Regions I and II from the heat pump
test procedure are combined and called Region I. Externally vented
refrigerators need only be tested at 90 deg.F and 60 deg.F, and from
such measurements, application of the correction factor, and
application of the energy profile equation, the unit's average per
cycle energy consumption can be determined for the nation as a whole
and for each of the four regions of the country. The Department
recognizes the Federal Trade Commission (FTC) has authority to
prescribe labeling requirements for all types of refrigerators and
other covered products and may require fact sheets containing regional
performance information. The proposed energy consumption measurement
formulas would satisfy the FTC's requirements.
7. Reporting requirements. The Department is proposing to add a
reporting requirement for externally vented refrigerators and
refrigerator-freezers. The energy savings due to externally venting a
refrigerator or refrigerator-freezer is a function of the outdoor air
temperature, therefore, externally vented refrigerators and
refrigerator-freezer's energy use will depend on climate. The
Department proposes to require that a manufacturer's certification
report include the national average annual energy use for externally
vented refrigerators and refrigerator-freezers. Separate reporting of
regional per cycle energy consumption would not be required.
III. Review Under the National Environmental Policy Act of 1969
In this rule, the Department proposes amendments to the test
procedures for refrigerators and refrigerator-freezers to include
externally vented refrigerators and refrigerator-freezers. The
Department has determined that this rule is covered under the
Categorical Exclusion found at paragraph A.6 of appendix A to Subpart
D, 10 CFR Part 1021, which applies to the establishment of procedural
rulemakings. This Proposed Rule is also a procedural rulemaking and its
implementation will not affect the
[[Page 16742]]
quality or distribution of energy usage and therefore will not result
in any environmental impacts. Accordingly, neither an environmental
assessment nor an environmental impact statement is required.
IV. Regulatory Review
Today's regulatory proposal has been determined not to be a
``significant regulatory action'' under Executive Order 12866,
``Regulatory Planning and Review,'' (58 FR 51735, October 4, 1993).
Accordingly, today's action was not subject to review under the
Executive Order by the Office of Information and Regulatory Affairs.
V. Regulatory Flexibility Review
The proposed rule has been reviewed under the Regulatory
Flexibility Act, Pub. L. 96-354 (42 U.S.C. 601-612) which requires
preparation of a regulatory flexibility analysis for any regulation
that will have a significant economic impact on a substantial number of
small entities, i.e., small businesses and small government
jurisdictions. The proposed rule would not have significant economic
impact on manufacturers of externally vented refrigerators and
refrigerator-freezers. The rule, if promulgated, would modify the
testing methods that currently apply. DOE accordingly certifies that
the proposed rule would not, if promulgated, have a significant
economic impact on a substantial number of small entities and that
preparation of a regulatory flexibility analysis is not warranted.
VI. ``Takings'' Assessment Review
It has been determined pursuant to Executive Order 12630 (52 FR
8859, March 18, 1988) that this proposed regulation, if adopted, would
not result in any takings which might require compensation under the
Fifth Amendment to the United States Constitution.
VII. Federalism Review
Executive Order 12612 (52 FR 41685, October 30, 1987) requires that
regulations or rules be reviewed for any substantial direct effects on
States, on the relationship between the Federal Government and the
States, or on the distribution of power and responsibilities among
various levels of Government. If there are sufficient substantial
direct effects, the Executive Order 12612 requires the preparation of a
Federalism assessment to be used in decisions by senior policy makers
in promulgating or implementing the regulation.
The proposed rule published today would not alter the distribution
of authority and responsibility to regulate in this area. The proposed
rule would only revise a currently applicable DOE test procedure to
accommodate a technological development in the manufacture of
refrigerators and refrigerator-freezers. Accordingly, DOE has
determined that preparation of a federalism assessment is unnecessary.
VIII. Paperwork Reduction Act Review
This proposed rule contains no new collections of information under
the Paperwork Reduction Act, 44 U.S.C. 3501 et seq.
IX. Review Under Unfunded Mandates Reform Act of 1995
Section 202 of the Unfunded Mandates Reform Act of 1995 (``Unfunded
Mandates Act'') requires that the Department prepare a budgetary impact
statement before promulgating a rule that includes a Federal mandate
that may result in expenditure by state, local, and tribal governments,
in the aggregate, or by the private sector, of $100 million or more in
any one year. The budgetary impact statement must include: (i)
Identification of the Federal law under which the rule is promulgated;
(ii) a qualitative and quantitative assessment of anticipated costs and
benefits of the Federal mandate and an analysis of the extent to which
such costs to state, local, and tribal governments may be paid with
Federal financial assistance; (iii) if feasible, estimates of the
future compliance costs and of any disproportionate budgetary effects
the mandate has on particular regions, communities, non-Federal units
of government, or sectors of the economy; (iv) if feasible, estimates
of the effect on the national economy; and (v) a description of the
Department's prior consultation with elected representatives of state,
local, and tribal governments and a summary and evaluation of the
comments and concerns presented.
The Department has determined that the action proposed today does
not include a Federal mandate that may result in estimated costs of
$100 million or more to state, local or to tribal governments in the
aggregate or to the private sector. Therefore, the requirements of
Sections 203 and 204 of the Unfunded Mandates Act do not apply to this
action.
X. Review Under Executive Order 12988, ``Civil Justice Reform''
With respect to the review of existing regulations and the
promulgation of new regulations, Section 3(a) of Executive Order 12988,
``Civil Justice Reform,'' 61 FR 4729 (February 7, 1996), imposes on
executive agencies the general duty to adhere to the following
requirements: (1) Eliminate drafting errors and ambiguity; (2) write
regulations to minimize litigation; and (3) provide a clear legal
standard for affected conduct rather than a general standard and
promote simplification and burden reduction. With regard to the review
required by Section 3(a), Section 3(b) of the Executive Order
specifically requires that Executive agencies make every reasonable
effort to ensure that the regulation: (1) Clearly specifies the
preemptive effect, if any; (2) clearly specifies any effect on existing
Federal law or regulation; (3) provide a clear legal standard for
affected conduct while promoting simplification and burden reduction;
(4) specifies the retroactive effect, if any; (5) adequately defines
key terms; and (6) addresses other important issues affecting clarity
and general draftsmanship under any guidelines issued by the Attorney
General. Section 3(c) of the Executive Order requires Executive
agencies to review regulations in light of applicable standards Section
3(a) and Section 3(b) to determine whether they are met or it is
unreasonable to meet one or more of them. DOE reviewed today's proposed
rulemaking under the standards of Section 3 of the Executive Order and
determined that, to the extent permitted by law, they meet the
requirements of those standards.
XI. Public Comment Procedures
A. Written Comment Procedures
Interested persons are invited to participate in the rulemaking by
submitting data, comments, or information with respect to the proposed
test procedures set forth in this notice to the address indicated at
the beginning of the notice.
Comments should be identified both on the envelope and on the
documents as ``Test Procedures for Refrigerators and Refrigerator-
Freezers,'' Docket No. EE-RM-97-118. Ten (10) copies are requested to
be submitted. In addition, the Department requests that an electronic
copy (3\1/2\'' diskette) of the comments on WordPerfectTM 6.1 be
provided. All submittals received by the date specified at the
beginning of this notice will be considered by the Department of Energy
before final action is taken on the proposed amendments.
Pursuant to the provisions of 10 CFR 1004.11, any person submitting
information that he or she believes to be
[[Page 16743]]
confidential and exempt by law from public disclosure should submit one
complete copy of the document and ten (10) copies, if possible, from
which the information believed to be confidential has been deleted. The
Department of Energy will make its own determination with regard to the
confidential status of the information and treat it according to its
determination.
Factors of interest to DOE when evaluating requests to treat as
confidential information that has been submitted include: (1) A
description of the items; (2) an indication as to whether and why such
items are customarily treated as confidential within the industry; (3)
whether the information is generally known by or available from other
sources; (4) whether the information has previously been made available
to others without obligation concerning its confidentiality; (5) an
explanation of the competitive injury to the submitting person that
would result from public disclosure; (6) an indication as to when such
information might lose its confidential character due to the passage of
time; and (7) why disclosure of the information would be contrary to
the public interest.
B. Issues for Public Comment
The Department of Energy is interested in receiving comments and
data concerning the suitability and workability of these test
procedures. Also, the Department welcomes comment on improvements or
alternatives to these approaches. In particular, DOE is interested in
gathering comments on the following:
The appropriateness of providing test procedures for
externally vented refrigerators and refrigerator-freezers.
The definition of externally vented refrigerators and
refrigerator-freezers and the applicability of the proposed revisions
of the test procedures.
The interaction of the externally vented refrigerator and
refrigerator/freezer and its associated air conduits and building
envelope penetration with the building heating and cooling loads.
The effects on energy conservation if externally vented
refrigerators and refrigerator-freezers are installed without the
outside air connection, and methods for adjusting the test results to
account for the likely failure of some consumers to make use of this
feature.
The appropriate test conditions for externally vented
refrigerators and refrigerator-freezers, including the selection of
outside air temperatures at which testing should occur.
The appropriateness of the correction factor to account
for the externally vented refrigerator and refrigerator-freezer's
testing advantage resulting from the 90 deg.F test temperature.
The appropriateness of the energy profile equations and
the derivation of formulas for computing energy consumption from test
results.
The appropriateness and means of measuring national and
regional average per cycle energy consumption.
List of Subjects in 10 CFR Part 430
Administrative practice and procedure, Energy conservation,
Household appliances.
Issued in Washington, DC, March 24, 1997.
Christine A. Ervin,
Assistant Secretary, Energy Efficiency and Renewable Energy.
For the reasons set forth in the preamble, Part 430 of Chapter II
of Title 10, Code of Federal Regulations is proposed to be amended as
follows:
PART 430--ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS
1. The authority citation for Part 430 continues to read as
follows:
Authority: 42 U.S.C. 6291-6309.
2. Section 430.23 (a) is amended in the following respects:
Subpart B--Test Procedures
Sec. 430.23 Test procedures for measures of energy consumption.
(a) Refrigerators and refrigerator-freezers. (1) The estimated
annual operating cost for electric refrigerators and electric
refrigerator-freezers without an anti-sweat heater switch shall be the
product of the following three factors:
(i) The representative average-use cycle of 365 cycles per year,
(ii) The average per-cycle energy consumption for the standard
cycle in kilowatt-hours per cycle, determined according to 6.2 or 6.3.6
of appendix A1 of this subpart for the non-externally vented or
externally vented units, respectively, and
(iii) The representative average unit cost of electricity in
dollars per kilowatt-hour as provided by the Secretary, the resulting
product then being rounded off to the nearest dollar per year.
(2) The estimated annual operating cost for electric refrigerators
and electric refrigerator-freezers with an anti-sweat heater switch
shall be the product of the following three factors:
(i) The representative average-use cycle of 365 cycles per year,
(ii) Half the sum of the average per-cycle energy consumption for
the standard cycle and the average per-cycle energy consumption for a
test cycle type with the anti-sweat heater switch in the position set
at the factory just prior to shipping, each in kilowatt-hours per
cycle, determined according to 6.2 or 6.3.6 of appendix A1 of this
subpart for the non-externally vented or externally vented units,
respectively, and
(iii) The representative average unit cost of electricity in
dollars per kilowatt-hour as provided by the Secretary, the resulting
product then being rounded off to the nearest dollar per year.
(3) The estimated annual operating cost for any other specified
cycle type for electric refrigerators and electric refrigerator-
freezers shall be the product of the following three factors:
(i) The representative average-use cycle of 365 cycles per year,
(ii) The average per-cycle energy consumption for the specified
cycle type, in kilowatt-hours per cycle, determined according to 6.2 or
6.3.6 of appendix A1 of this subpart for the non-externally vented or
externally vented units, respectively, and
(iii) The representative average unit cost of electricity in
dollars per kilowatt-hour as provided by the Secretary, the resulting
product then being rounded off to the nearest dollar per year.
(4) The energy factor for electric refrigerators and electric
refrigerator-freezers, expressed in cubic feet per kilowatt-hour per
cycle, shall be--
(i) For electric refrigerators and electric refrigerator-freezers
not having an anti-sweat heater switch, the quotient of
(A) The adjusted total volume in cubic feet, determined according
to 6.1 of Appendix A1 of this subpart, divided by
(B) The average per-cycle energy consumption for the standard cycle
in kilowatt-hours per cycle, determined according to 6.2 or 6.3.6 of
appendix A1 of this subpart for the non-externally vented or externally
vented units, respectively, the resulting quotient then being rounded
off to the second decimal place, and
(ii) For electric refrigerators and electric refrigerator-freezers
having an anti-sweat heater switch, the quotient of
(A) The adjusted total volume in cubic feet, determined according
to 6.1 of Appendix A1 of this subpart, divided by
(B) Half the sum of the average per-cycle energy consumption for
the standard cycle and the average per-cycle energy consumption for a
test cycle type with the anti-sweat heater switch in the position set
at the factory just prior to
[[Page 16744]]
shipping, each in kilowatt-hours per cycle, determined according to 6.2
or 6.3.6 of appendix A1 of this subpart for the non-externally vented
or externally vented units, respectively, the resulting quotient then
being rounded off to the second decimal place.
(5) The annual energy use of electric refrigerators and electric
refrigerator-freezers equals the representative average use cycle of
365 cycles per year times the average per-cycle energy consumption for
the standard cycle in kilowatt-hours per cycle, determined according to
6.2 or 6.3.6 of appendix A1 of this subpart for the non-externally
vented or externally vented units, respectively.
(6) Other useful measures of energy consumption for electric
refrigerators and electric refrigerator-freezers shall be those
measures of energy consumption for electric refrigerators and electric
refrigerator-freezers which the Secretary determines are likely to
assist consumers in making purchasing decisions which are derived from
the application of appendix A1 of this subpart.
(7) The estimated regional annual operating cost for externally
vented electric refrigerators and externally vented electric
refrigerator-freezers without an anti-sweat heater switch shall be the
product of the following three factors:
(i) The representative average cycle of 365 cycles per year,
(ii) The regional average per-cycle energy consumption for the
standard cycle in kilowatt-hours per cycle, determined according to
6.3.7 of appendix A1 of this subpart and
(iii) The representative average unit cost of electricity in
dollars per kilowatt-hour as provided by the Secretary, the resulting
product then being rounded off to the nearest dollar per year.
(8) The estimated regional annual operating cost for externally
vented electric refrigerators and externally vented electric
refrigerator-freezers with an anti-sweat heater switch shall be the
product of the following three factors:
(i) The representative average cycle of 365 cycles per year,
(ii) Half the sum of the average per-cycle energy consumption for
the standard cycle and the regional average per-cycle energy
consumption for a test cycle type with the anti-sweat heater switch in
the position set at the factory just prior to shipping, each in
kilowatt-hours per cycle, determined according to 6.3.7 of appendix A1
of this subpart, and
(iii) The representative average unit cost of electricity in
dollars per kilowatt-hour as provided by the Secretary, the resulting
product then being rounded off to the nearest dollar per year.
(9) The estimated regional annual operating cost for any other
specified cycle type for externally vented electric refrigerators and
externally vented electric refrigerator-freezers shall be the product
of the following three factors:
(i) The representative average cycle of 365 cycles per year,
(ii) The regional average per-cycle energy consumption for the
specified cycle type, in kilowatt-hours per cycle, determined according
to 6.3.7 of appendix A1 of this subpart, and
(iii) The representative average unit cost of electricity in
dollars per kilowatt-hour as provided by the Secretary, the resulting
product then being rounded off to the nearest dollar per year.
* * * * *
3. Section 1 of Appendix A1 is amended by adding the following
definition:
Appendix A1 to Subpart B of Part 430--Uniform Test Method for Measuring
the Energy Consumption of Electric Refrigerators and Electric
Refrigerator-Freezers
1. Definitions
* * * * *
1.12 Externally vented refrigerator or refrigerator-freezer
means an electric refrigerator or electric refrigerator-freezer
that: has an enclosed condenser or an enclosed condenser/compressor
compartment and a set of air ducts for transferring the exterior air
from outside the building envelope into, through and out of the
refrigerator or refrigerator-freezer cabinet; is capable of mixing
exterior air with the room air before discharging into, through, and
out of the condenser or condenser/compressor compartment; includes
thermostatically controlled dampers or controls that enable the
proper mixing of the exterior and room air at low outdoor
temperatures, and the exclusion of exterior air when the outdoor air
temperature is above 80 deg.F or the room air temperature. It may
have a thermostatically actuated exterior air fan.
4. Section 2 of Appendix A1 is amended by adding the following new
sections:
2. Test Conditions
* * * * *
2.6 Exterior air for externally vented refrigerator or
refrigerator-freezer. An exterior air source shall be provided with
adjustable temperature and pressure capabilities. The exterior air
temperature shall be adjustable from 351 deg.F
(1.70.6 deg.C) to 901 deg.F
(32.20.6 deg.C).
2.6.1 Air duct. The exterior air shall pass from the exterior
air source to the test unit through an insulated air duct.
2.6.2 Air temperature measurement. The air temperature entering
the condenser or condenser/compressor compartment shall be
maintained to 3 deg.F (1.7 deg.C) during the
stabilization and test periods and shall be measured at the inlet
point of the condenser or condenser/compressor compartment
(``condenser inlet''). Temperature measurements shall be taken from
at least three temperature sensors or one sensor per 4 square inches
of the air duct cross sectional area, whichever is greater, and
shall be averaged. For a unit that has a condenser air fan, a
minimum of three temperature sensors at the condenser fan discharge
shall be required. Temperature sensors shall be arranged to be at
the centers of equally divided cross sectional areas. The exterior
air temperature, at its source, shall be measured and maintained to
1 deg.F (0.6 deg.C) during the test period. The
temperature measuring devices shall have an error not greater than
0.5 deg.F (0.3 deg.C). Measurements of the
air temperature during the test period shall be taken at regular
intervals not to exceed four minutes.
2.6.3 Exterior air static pressure. The exterior air static
pressure at the inlet point of the unit shall be adjusted to
maintain a negative pressure of 0.20'' 0.05'' water
column (62 Pa12.5 Pa) for all air flow rates supplied to
the unit. The pressure sensor shall be located on a straight duct
with a distance of at least 7.5 times the diameter of the duct
upstream and a distance of at least 3 times the diameter of the duct
downstream. There shall be four static pressure taps at 90 deg.
angles apart. The four pressures shall be averaged by
interconnecting the four pressure taps. The air pressure measuring
instrument shall have an error not greater than 0.01'' water column
(2.5 Pa).
5. Section 5 of Appendix A1 is amended by adding the following new
sections:
5. Test measurements
* * * * *
5.4 Externally vented refrigerator or refrigerator-freezer
units. All test measurements for the externally vented refrigerator
or refrigerator-freezer shall be made in accordance with the
requirements of other sections of this Appendix, except as modified
in this section 5.4 or other sections expressly applicable to
externally vented refrigerators or refrigerator-freezers.
5.4.1 Operability of thermostatic and mixing of air controls.
Prior to conducting energy consumption tests, the operability of
thermostatic controls that permit the mixing of exterior and ambient
air when exterior air temperatures are less than 60 deg.F must be
verified. The operability of such controls shall be verified by
operating the unit under ambient air temperature of 90 deg.F and
exterior air temperature of 45 deg.F. If the inlet air entering the
condenser or condenser/compressor compartment is maintained at 60
deg.F, plus or minus three degrees, energy consumption of the unit
shall be measured under sections 5.4.2.2, and 5.4.2.3. If the inlet
air entering the condenser or condenser/compressor compartment is
not maintained at 60 deg.F, plus or minus three degrees, energy
[[Page 16745]]
consumption of the unit shall also be measured under section
5.4.2.4.
5.4.2 Energy consumption tests.
5.4.2.1 Correction factor test. To enable calculation of a
correction factor, K, two full cycle tests shall be conducted to
measure energy consumption of the unit with air mixing controls
disabled and the condenser inlet air temperatures set at 90 deg.F
(32.2 deg.C) and 80 deg.F (26.7 deg.C). Both tests shall be
conducted with all compartment temperature controls set at the
position midway between their warmest and coldest settings and the
anti-sweat heater switch off. Record the energy consumptions
ec90 and ec80, in kWh/day.
5.4.2.2 Energy consumption at 90 deg.F. The unit shall be
tested at 90 deg.F (32.2 deg.C) exterior air temperature to record
the energy consumptions (e90)i in kWh/day. For a given
setting of the anti-sweat heater, i corresponds to each of the two
states of the compartment temperature control positions.
5.4.2.3 Energy consumption at 60 deg.F. The unit shall be
tested at 60 deg.F (26.7 deg.C) exterior air temperature to record
the energy consumptions (e60)i in kWh/day. For a given
setting of the anti-sweat heater, i corresponds to each of the two
states of the compartment temperature control positions.
5.4.2.4 Energy consumption if mixing controls do not operate
properly. If the operability of temperature and mixing controls has
not been verified as required under section 5.4.1, the unit shall be
tested at 50 deg.F (10.0 deg.C) and 30 deg.F (-1.1 deg.C)
exterior air temperatures to record the energy consumptions
(e50)i and (e30)i. For a given setting of the
anti-sweat heater, i corresponds to each of the two states of the
compartment temperature control positions.
6. Section 6 of Appendix A1 is amended by adding the following new
sections:
6. Calculation of Derived Results from Test Measurements
* * * * *
6.3 Externally vented refrigerator or refrigerator-freezers.
Per-cycle energy consumption measurements for the externally vented
refrigerator or refrigerator-freezer shall be calculated in
accordance with the requirements of this Appendix, as modified in
sections 6.3.1--6.3.7.
6.3.1 Correction factor. A correction factor, K, shall be
calculated as:
K = ec90/ec80
Where ec90 and ec80 = the energy consumption test results
as determined under section 5.4.2.1.
6.3.2 Combining test results of different settings of
compartment temperature controls. For a given setting of the anti-
sweat heater, follow the calculation procedures of section 6.2 to
combine the test results for energy consumption of the unit at
different temperature control settings for each condenser inlet air
temperature tested under sections 5.4.2.2, 5.4.2.3, and 5.4.2.4,
where applicable, (e90)i, (e60)i,
(e50)i, and (e30)i. The combined values are
90, 60, 50, and
30, where applicable, in kWh/day.
6.3.3 Energy consumption corrections. For a given setting of
the anti-sweat heater, the energy consumptions 90,
60, 50, and 30 calculated
in section 6.3.2 shall be adjusted by multiplying the correction
factor K to obtain the corrected energy consumptions per day, in
kWh/day:
E90 = K x 90,
E60 = K x 60,
E50 = K x 50, and
E30 = K x 30
Where,
K is determined under section 6.3.1, and 90,
60, 50, and 30 are
determined under section 6.3.2.
6.3.4 Energy profile equation. For a given setting of the anti-
sweat heater, the energy consumption Ex, in kWh/day, at a
specific exterior air temperature between 80 deg.F (26.7 deg.C)
and 60 deg.F (26.7 deg.C) shall be calculated by the following
equation:
Ex = a + bTx,
Where,
Tx = exterior air temperature in deg.F;
a = 3E60-2E90, in kWh/day;
b = (E90-E60)/30, in kWh/day per deg.F.
6.3.5 Energy consumption at 80 deg.F (26.7 deg.C), 75 deg.F
(23.9 deg.C) and 65 deg.F (18.3 deg.C). For a given setting of
the anti-sweat heater, calculate the energy consumptions at 80
deg.F (26.7 deg.C), 75 deg.F (23.9 deg.C) and 65 deg.F (18.3
deg.C) exterior air temperatures, E80, E75 and E65,
respectively, in kWh/day, using the equation in 6.3.4.
6.3.6 National average per cycle energy consumption. For a
given setting of the anti-sweat heater, calculate the national
average energy consumption, EN, in kWh/day, using one of the
following equations:
EN = 0.523 x E60 + 0.165 x E65 + 0.181 x E75
+ 0.131 x E80, for unit which is not tested under section
5.4.2.4,
EN = 0.257 x E30 + 0.266 x E50 + 0.165 x
E65 + 0.181 x E75 + 0.131 x E80, for unit tested
under section 5.4.2.4,
Where,
E30, E50, and E60 are defined in 6.3.3,
E65, E75, and E80 are defined in 6.3.5, and the
coefficients are weather associated weighting factors.
6.3.7 Regional average per cycle energy consumption. If
regional average per cycle energy consumption is required to be
calculated, for a given setting of the anti-sweat heater, calculate
the regional average per cycle energy consumption, ER, in kWh/
day, for the regions in figure 1 using one of the following
equations and the coefficients in the table A:
ER = a1 x E60 + c x E65 + d x E75 + e x
E80, for a unit that is not required to be tested under section
5.4.2.4,
ER = a x E30 + b x E50 + c x E65 + d x E75
+ e x E80, for a unit tested under section 5.4.2.4,
Where,
E30, E50, and E60 are defined in 6.3.3,
E65, E75, and E80 are defined in 6.3.5, and a1,
a, b, c, d, e are weather associated weighting factors for the
Regions, as specified in Table A:
Table A.--Coefficients for Calculating Regional Average per Cycle Energy Consumption
[Weighting Factors]
----------------------------------------------------------------------------------------------------------------
Regions a1 a b c d e
----------------------------------------------------------------------------------------------------------------
I................................. 0.282 0.039 0.244 0.194 0.326 0.198
II................................ 0.486 0.194 0.293 0.191 0.193 0.129
III............................... 0.584 0.302 0.282 0.178 0.159 0.079
IV................................ 0.664 0.420 0.244 0.161 0.121 0.055
----------------------------------------------------------------------------------------------------------------
BILLING CODE 6450-01-P
[[Page 16746]]
[GRAPHIC] [TIFF OMITTED] TP08AP97.020
BILLING CODE 6450-01-C
Sec. 430.62 [Amended]
7. Section 430.62(a)(2) is amended by inserting after ``(for
refrigerators, refrigerator-freezers, and freezers),'' in the first
sentence, the following: ``the national average annual energy use and
adjusted volume (for externally vented refrigerators and refrigerator-
freezers),''.
[FR Doc. 97-8937 Filed 4-7-97; 8:45 am]
BILLING CODE 6450-01-P