Mine Shift Atmospheric Conditions; Respirable Dust Sample

Federal RegisterFeb 3, 1998

Ask Donna

What actually matters in this document.

Text

[Federal Register Volume 63, Number 22 (Tuesday, February 3, 1998)]

[Notices]

[Pages 5664-5687]

From the Federal Register Online via the Government Publishing Office [www.gpo.gov]

[FR Doc No: 97-33934]

[[Page 5663]]

_______________________________________________________________________

Part V

Department of Labor

_______________________________________________________________________

Mine Safety and Health Administration

_______________________________________________________________________

Department of Health and Human Services

_______________________________________________________________________

Centers for Disease Control and Prevention

_______________________________________________________________________

Mine Shift Atmospheric Conditions; Respirable Dust Sample; and Coal

Mine Respirable Dust Standard Noncompliance Determinations; Correction

and Republication; Notices

Federal Register / Vol. 63, No. 22 / Tuesday, February 3, 1998 /

Notices

[[Page 5664]]

DEPARTMENT OF LABOR

Mine Safety and Health Administration

DEPARTMENT OF HEALTH AND HUMAN SERVICES

Centers for Disease Control and Prevention

RIN 1219-AA82

Mine Shift Atmospheric Conditions; Respirable Dust Sample

Correction and Republication

Note: For the convenience of the user, notice document 97-33934

is being reprinted in its entirety because of numerous errors in the

document originally appearing at 62 FR 68372-68395, December 31,

1997. Those wishing to see a listing of corrections, please call

Patricia Silvey, Mine Safety and Health Administration, 703-235-

1910.

AGENCIES: Mine Safety and Health Administration, Labor, National

Institute for Occupational Safety and Health, Centers for Disease

Control and Prevention, HHS.

ACTION: Final notice of joint finding.

-----------------------------------------------------------------------

SUMMARY: This notice announces that the Secretary of Labor and the

Secretary of Health and Human Services (the Secretaries) find, in

accordance with sections 101 and 202(f)(2) of the Federal Mine Safety

and Health Act of 1977 (Mine Act), 30 U.S.C. 811 and 842(f)

respectively, that the average concentration of respirable dust to

which each miner in the active workings of a coal mine is exposed can

be accurately measured over a single shift. This notice should be read

in conjunction with the notice published separately by the Mine Safety

and Health Administration (MSHA) elsewhere in today's Federal Register.

The Secretaries are rescinding the previous finding, which was proposed

on July 17, 1971 and issued on February 23, 1972, by the Secretary of

the Interior and the Secretary of Health, Education and Welfare.

EFFECTIVE DATE: This notice will be effective on March 2, 1998.

FOR FURTHER INFORMATION CONTACT: Patricia W. Silvey, Director, Office

of Standards, Regulations and Variances; MSHA; 703-235-1910.

SUPPLEMENTARY INFORMATION: In accordance with section 202(f)(2) and

section 101 of the Mine Act, this notice is published jointly by the

Secretaries of the Departments of Labor, and Health and Human Services.

I. Introduction

For as long as miners have taken coal from the ground, the presence

of respirable dust in coal mines has been a source of health problems

for miners. Coal workers' pneumoconiosis, one of the most insidious of

occupational diseases, is caused by deposits of coal mine dust in the

lung and is known as ``black lung disease.'' The disability that may

result from these deposits can range from slightly impaired lung

function to significant decreases in lung function resulting in

breathlessness, recurrent chest illness, and even heart failure. In

addition, the disease may progress even after the miner is no longer

exposed to coal mine dust.

The Federal Coal Mine Health and Safety Act of 1969 (Coal Act)

established the first comprehensive dust standard for underground U.S.

coal mines by setting a limit of 2.0 milligrams of respirable coal mine

dust per cubic meter of air (mg/m3). The 2.0 mg/

m3 standard sets a limit on the concentration of respirable

coal mine dust permitted in the mine atmosphere during each shift to

which each miner in the active workings of a mine is exposed. Congress

was convinced that the only way each miner could be protected from

black lung disease or other occupational dust disease was by limiting

the amount of respirable dust allowed in the air that miners breathe.

The Coal Act was subsequently amended by the Federal Mine Safety

and Health Act of 1977 (Mine Act), 30 U.S.C. 801 et seq. The standard

limiting respirable dust in the mine atmosphere to 2.0 mg/m3

was retained in the Mine Act, which also required that ``each operator

shall continuously maintain the average concentration of respirable

dust in the mine atmosphere during each shift to which each miner in

the active workings of such mine is exposed at or below 2.0 milligrams

of respirable dust per cubic meter of air.'' Section 202(b)(2). (Other

provisions in the Mine Act, sections 205 and 203(b)(2), provide for

lowering the applicable standard when quartz is present and when miners

with evidence of pneumoconiosis have elected to work in a low-dust work

environment.)

Today, dust levels in underground U.S. coal mines are significantly

lower than they were when the Coal Act was passed. Federal mine

inspector sampling results during 1968-1969 show that the average dust

concentration in the environment of a continuous miner operator was 7.7

mg/m3. Current sampling indicates that the average dust

level for that occupation has been reduced by 83 percent to 1.3 mg/

m3. Despite this progress, the Secretaries believe that

occupational lung disease continues to present a serious health risk to

coal miners. In November 1995, the National Institute for Occupational

Safety and Health (NIOSH) issued a criteria document which concluded

that coal miners in our country continue to be at risk for developing

black lung disease.

The Secretary of Labor believes that miners' health can be further

protected from the debilitating effects of black lung disease by

improving their workplace conditions through more effective assessment

of respirable dust concentrations during individual, full shifts. On

February 18, 1994, the Secretary of Labor and the Secretary of Health

and Human Services published a notice in the Federal Register proposing

to find that the average concentration of respirable dust to which each

miner in the active workings of a coal mine is exposed can be

accurately measured over a single shift in accordance with section

202(f)(2) of the Mine Act (56 FR 8357). Additionally, the Secretaries

proposed to rescind the previous finding, which was proposed on July

17, 1971 (36 FR 13286) and issued on February 23, 1972 (37 FR 3833), by

the Secretary of the Interior and the Secretary of Health, Education

and Welfare.

II. General Discussion

The issues related to this finding are complex and highly

technical. The Agencies have organized this final notice to allow

interested persons to first consider pertinent introductory material on

the Agencies' 1972 notice and its recision, and a short overview of the

NIOSH mission and assessment of this finding, as well as those aspects

of MSHA's coal mine respirable dust program relevant to this finding.

Following this introductory material is a discussion of the

``measurement objective,'' or what the Secretaries intend to measure

with a single, full-shift measurement, and the use of the NIOSH

Accuracy Criterion for determining whether a single, full-shift

measurement will ``accurately represent'' the full-shift atmospheric

dust concentration. Next, the validity of the sampling process is

addressed, including the performance of the approved sampler unit,

sample collection procedures, and sample processing. The concept of

measurement uncertainty is then addressed, and why sources of dust

concentration variability and various other factors are not relevant to

the finding. Finally, the notice explains how the total measurement

uncertainty was quantified, and how the accuracy of a single, full-

shift measurement was shown to meet the NIOSH Accuracy Criterion.

Several Appendices, which

[[Page 5665]]

contain relevant technical information, are attached and incorporated

with this notice. The Agencies have additionally included references to

the Appendices throughout this notice.

A. The 1971/1972 Joint Notice of Finding

In 1971 the Secretary of the Interior and the Secretary of Health,

Education and Welfare proposed, and in 1972 issued, a joint finding

under the Coal Act. The finding concluded that a single shift

measurement would not, after applying valid statistical techniques,

accurately represent the atmospheric conditions to which the miner is

continuously exposed. For the reasons that follow, the Secretaries

believe that the 1972 joint finding was incorrect.

Section 202(b)(2) of the Coal Act provided that ``each operator

shall continuously maintain the average concentration of respirable

dust in the mine atmosphere during each shift to which each miner in

the active workings of such mine is exposed at or below [the applicable

respirable dust standard].'' In addition, the term ``average

concentration'' was defined in section 202(f) of the Coal Act as

follows:

* * * the term ``average concentration'' means a determination

which accurately represents the atmospheric conditions with regard

to respirable dust to which each miner in the active workings of a

mine is exposed (1) as measured during an 18 month period following

the date of enactment of this Act, over a number of continuous

production shifts to be determined by the Secretary of the Interior

and the Secretary of Health, Education and Welfare, and (2) as

measured thereafter, over a single shift only, unless the Secretary

of the Interior and the Secretary of Health, Education and Welfare

find, in accordance with the provisions of section 101 of this Act,

that such single shift measurements will not, after applying valid

statistical techniques to such measurement, accurately represent

such atmospheric conditions during such shift.

Therefore, 18 months after the statute was enacted, the ``average

concentration'' of respirable dust in coal mines was to be measured

over a single shift only, unless the Secretaries found that doing so

would not accurately represent mine atmospheric conditions during such

shift. If the Secretaries found that a single shift measurement would

not, after applying valid statistical techniques, accurately represent

mine atmospheric conditions during such shift, then the interim

practice of averaging measurements ``over a number of continuous

production shifts'' was to continue.

On December 16, 1969, the U.S. Congress published a Conference

Report in support of the new Coal Act. The Report refers to section

202(f) by noting that:

At the end of this 18 month period, it requires that the

measurements be over one production shift only, unless the

Secretar[ies] * * * find, in accordance with the standard setting

procedures of section 101, that single shift measurements will not

accurately represent the atmospheric conditions during the measured

shift to which the miner is continuously exposed [Conference Report,

page 75].

This Report is inconsistent with the wording of the section 202(f),

which seeks to apply a single, full-shift measurement to ``accurately

represent such atmospheric conditions during such shift.'' Section

202(f) does not mention continuous exposure. The Secretaries believe

that the use of this phrase is confusing, and to the extent that any

weight of interpretation can be given to the legislative history, that

the Senate's Report of its bill provides a clearer interpretation of

section 202(f) when read together with the statutory language. The

Senate Committee noted in part that:

The committee * * * intends that the dust level not exceed the

specified standard during any shift. It is the committee's intention

that the average dust level at any job, for any miner in any active

working place during each and every shift, shall be no greater than

the standard.

Following passage of the Coal Act, the Bureau of Mines (MSHA's

predecessor Agency within the Department of the Interior) expressed a

preference for multi-shift sampling. Correspondence exchanged during

that time period of 1969 to 1971 reflected concern over the

technological feasibility of controlling dust levels to the limits

established, and the potentially disruptive effects of mine closure

orders because of noncompliance with the respirable dust limits. Both

industry and government officials feared that basing noncompliance

determinations on single, full-shift measurements would increase those

problems. In June 1971, the then-Associate Solicitor for Mine Safety

and Health at the Department of the Interior issued a legal

interpretation of section 202(f), concluding that the average dust

concentration was to be determined by measurements that accurately

represent respirable dust in the mine atmosphere over time rather than

during a shift. On July 17, 1971, the Secretaries of the Interior and

of Health, Education and Welfare issued a proposed notice of finding

under section 202(f) of the Coal Act. The finding concluded that, ``a

single shift measurement of respirable dust will not, after applying

valid statistical techniques to such measurement, accurately represent

the atmospheric conditions to which the miner is continuously exposed''

(36 FR 13286).

In February, 1972, the final finding was issued (37 FR 3833). It

concluded that:

After careful consideration of all comments, suggestions, and

objections, it is the conclusion of the Secretary of the Interior

and the Secretary of Health, Education, and Welfare that a valid

statistical technique was employed in the computer analysis of the

data referred to in the proposed notice [footnote omitted] and that

the data utilized was accurate and supported the proposed finding.

Both Departments also intend periodically to review this finding as

new technology develops and as new dust sampling data becomes

available.

The Departments intend to revise part 70 of Title 30, Code of

Federal Regulations, to improve dust measuring techniques in order

to ascertain more precisely the dust exposure of miners. To

complement the present system of averaging dust measurements, it is

anticipated that the proposed revision would use a measurement over

a single shift to determine compliance with respirable dust

standards taking into account (1) the variation of dust and

instrument conditions inherent in coal mining operations, (2) the

quality control tolerance allowed in the manufacture of personal

sampler capsules, and (3) the variation in weighing precision

allowed in the Bureau of Mines laboratory in Pittsburgh.

The proposed finding, as set forth at 36 F.R. 13286, that a

measurement of respirable dust over a single shift only, will not,

after applying valid statistical techniques to such measurement,

accurately represent the atmospheric conditions to which the miner

under consideration is continuously exposed, is hereby adopted

without change.

As explained in the 1971 proposed finding, the average

concentration of all ten full-shift samples (from one occupation)

submitted from each working section under the regulations in effect at

the time (these were the ``basic samples'' referred to in the proposed

notice of finding) was compared with the average concentration of the

two most recently submitted samples, then to the three most recently

submitted samples, then to the four most recently submitted samples,

etc. In discussing the results of these comparisons the Secretaries

stated that `` * * * the average of the two most recently submitted

samples of respirable dust was statistically equivalent to the average

concentration of the current basic samples for each working section in

only 9.6 percent of the comparisons.''

The title of the 1971/1972 notice and the conclusion it reaches are

clearly inconsistent. The title states that it is a ``Notice of Finding

That Single Shift Measurements of Respirable Dust Will Not Accurately

Represent Atmospheric Conditions During Such Shift.''

[[Page 5666]]

However, the conclusion states that, ``* * * a single shift measurement

* * * will not, after applying valid statistical techniques * * *

accurately represent the atmospheric conditions to which the miner is

continuously exposed'' (emphasis added).

The Secretaries have determined that section 202(f) requires a

determination of accuracy with respect to ``atmospheric conditions

during such shift,'' not ``atmospheric conditions to which the miner is

continuously exposed'' (37 FR 3833). The statistical analysis

referenced in the 1971/1972 proposed and final findings simply did not

address the accuracy of a single, full-shift measurement in

representing atmospheric conditions during the shift on which it was

taken. For this and other reasons set forth in the notice, the

Secretaries hereby rescind the 1972 joint final finding.

III. NIOSH Mission Statement and Assessment of the Joint Finding

The National Institute for Occupational Safety and Health (NIOSH)

was created by Congress in the Occupational Safety and Health Act in

1970. The Act established NIOSH as part of the Department of Health and

Human Services to identify the causes of work-related diseases and

injuries, evaluate the hazards of new technologies, create new ways to

control hazards to protect workers, and make recommendations for new

occupational safety and health standards. Under section 501 of the Mine

Act, Congress gave specific research responsibilities to NIOSH in the

field of coal or other mine health. These responsibilities include the

authority to conduct studies, research, experiments and demonstrations,

in order ``to develop new or improved means and methods of reducing

concentrations of respirable dust in the mine atmosphere of active

workings of the coal or other mine,'' and also ``to develop techniques

for the prevention and control of occupational diseases of miners * *

*.''

When the initial finding, issued under section 202(f) of the Coal

Act, was published in 1972, both the Secretary of the Interior and the

Secretary of Health, Education and Welfare (the predecessor to the

Department of Health and Human Services) indicated that the finding

would be reassessed as new technology was developed, or new data became

available. The Secretary of Health and Human Services, through

delegated authority to the National Institute for Occupational Safety

and Health, has reconsidered the provisions of section 202(f) of the

Mine Act, reviewed the current state of technology and other scientific

advances since 1972, and has determined that the following innovations

and technological advancements are important factors in the

reassessment of the 1971/1972 joint finding.

In 1977 NIOSH published its ``Sampling Strategies Manual,'' which

provided a framework for the statistical treatment of occupational

exposure data [DHEW (NIOSH) Publication No. 77-173; Sec. 4.2.1].

Additionally, that year, NIOSH first published the NIOSH Accuracy

Criterion, which was developed as a goal for methods to be used by OSHA

for compliance determinations [DHEW (NIOSH) Publication No. 77-185; pp.

1-5]. In 1980, new mine health standards issued by the Secretary of

Labor (30 CFR parts 70, 71, and 90) improved the quality of the

sampling process by revising sampling, maintenance, and calibration

procedures. Prior to 1984, filter capsules used in sampling were

manually weighed by MSHA personnel using semi-micro balances, making

precision weights to the nearest 0.1 mg (100 micrograms). In 1984, a

fully-automated, robotic weighing system was introduced along with

state-of-the-art electronic microbalances. In 1994, the balances were

further upgraded, and in 1995 the weighing system was again improved,

increasing weighing sensitivity to the microgram level. Also, in 1987,

electronic flow-control sampling pump technology was introduced in the

coal mine dust sampling program with the use of MSA

FlowLiteTM pumps. 1 These new pumps compensate

for the changing filter flow-resistance that occurs due to dust

deposited during the sampling period. The second generation of

constant-flow sampling pumps was introduced in 1994, with the

introduction of the MSA Escort ELF pump. The automatic

correction provided by these new pumps improves the stability of the

sampler air flow rates and reduces the inaccuracies that were inherent

in the 1970-1980s vintage sampling pumps. One further improvement was

made in 1992 with the introduction of the new tamper-resistant filter

cassettes. Because of these evolving improvements to the sampling

process, a better understanding of statistical methods applied to

method accuracy, and a reconsideration of the requirements of section

202(f) of the Mine Act, the Secretary of Health and Human Services has

determined that the previous joint finding should be reevaluated.

---------------------------------------------------------------------------

\1\ Reference to specific equipment, trade names or

manufacturers does not imply endorsement by NIOSH or MSHA.

---------------------------------------------------------------------------

IV. MSHA Mission Statement and Overview of the Respirable Dust

Program

With the enactment of the Mine Act, Congress recognized that ``the

first priority and concern of all in the coal or other mining industry

must be the health and safety of its most precious resource--the

miner.'' Congress further realized that there ``is an urgent need to

provide more effective means and measures for improving the working

conditions and practices in the Nation's coal or other mines in order

to prevent death and serious physical harm, and in order to prevent

occupational diseases originating in such mines.'' With these goals in

mind, MSHA is given the responsibility to protect the health and safety

of the Nation's coal and other miners by enforcing the provisions of

the Mine Act.

A. The Coal Mine Respirable Dust Program

In 1970, federal regulations were issued by MSHA's predecessor

agency that established a comprehensive coal mine operator dust

sampling program, which required the environment of the occupation on a

working section exposed to the highest respirable dust concentration to

be sampled--the ``high risk occupation'' concept. All other occupations

on the section were assumed to be protected if the high risk occupation

was in compliance. Under this program, each operator was required to

initially collect and submit ten valid respirable dust samples to

determine the average dust concentration (across ten production

shifts). If analysis showed the average dust concentration to be within

the applicable dust standard, the operator was required to submit only

five valid samples a month. If compliance continued to be demonstrated,

the operator was required to take only five valid samples every other

month. The initial, monthly, and bimonthly sampling cycles were

referred to as the ``original,'' ``standard,'' and ``alternative

sampling'' cycles, respectively. When the average dust concentration

exceeded the standard, the operator reverted back to the standard

sampling cycle.

In addition to sampling the high risk occupation at specified

frequencies, each miner was sampled individually at different

intervals. However, these early individual sample results were not used

for enforcement but were provided to NIOSH for medical research

purposes.

MSHA revised these regulations in April 1980 (45 FR 23990) to

reduce the

[[Page 5667]]

operator sampling burden, to simplify the sampling process, and to

enhance the overall quality of the sampling program. The result was to

replace the various sampling cycles with a bimonthly sampling cycle and

to eliminate the requirement that each miner be sampled. These are the

regulations that currently govern the mine operator dust sampling

program, and which continue to be based on the high risk occupation

concept, now referred to as the ``designated occupation'' or ``D.O.''

sampling concept.

It should be noted that the preamble to the final rule amending the

regulations in April 1980 (45 FR 23997), explicitly refers to the use

of single versus multiple samples as it applies to the operator

respirable dust sampling program.

Compliance determinations will generally be based on the average

concentration of respirable dust measured by five valid respirable

dust samples taken by the operator during five consecutive shifts,

or five shifts worked on consecutive days. Therefore, the sampling

results upon which compliance determinations are made will more

accurately represent the dust in the mine atmosphere than would the

results of only a single sample taken on a single shift. In

addition, MSHA believes the revised sampling and maintenance and

calibration procedures prescribed by the final rule will

significantly improve the accuracy of sampling results.

At the time of these amendments, MSHA examined section 202(b)(2) of

the Coal Act, which was retained unchanged in the 1977 Mine Act. The

Agency stated in the preamble to the final rule that:

Although single-shift respirable dust sampling would be most

compatible with this single-shift standard, Congress recognized that

variability in sampling results could render single-shift samples

insufficient for compliance determinations. Consequently, Congress

defined ``average concentration'' in section 202(f) of the 1969 Coal

Act which is also retained in the 1977 Act.

MSHA believes that this interpretation merely recognized the two

ways of measurement authorized in section 202(f), and expressed the

preference on the part of MSHA in 1980 to retain multi-shift sampling

in the operator sampling program. The phrase used in the preamble to

the final rule reflects that MSHA understood that the 2.0 mg/

m3 limit was a single-shift standard, which was not to be

exceeded on a shift. The preamble referenced the continuous multi-shift

sampling and single-shift sampling conducted by the Secretary of the

Interior and the Secretary of Health, Education, and Welfare, and noted

that in the 1971/1972 proposed and final findings,

It had been determined after applying valid statistical

techniques, * * * that a single shift sample should not be relied

upon for compliance determinations when the respirable dust

concentration being measured was near 2.0 mg/m3.

Accordingly, the [Secretaries] prescribed consecutive multi-shift

samples to enforce the respirable dust standard.

The preamble provides no further explanation for the statement that

single-shift samples should not be relied on when the respirable dust

concentration being measured was near 2.0 mg/m3. Thus, the

1980 final rule, which reduced the number of samples that operators

were required to take for compliance determinations, merely reiterated

the rationale behind the 1971/1972 proposed and final findings

concerning single-shift samples, and did not address the accuracy of a

single, full-shift measurement.

MSHA continues to take an active role in sampling for respirable

dust by conducting inspections annually at each surface and underground

coal mine. During these inspections, MSHA inspectors collect samples on

multiple occupations to determine compliance with the applicable

standard, assess the effectiveness of the operator's dust control

program, quantify the level of crystalline silica (quartz) in the work

environment, and identify occupations other than the ``D.O.'' which may

be at risk and should be monitored by the mine operator.

Depending on the concentration of dust measured, an MSHA inspector

may terminate sampling after the first day if levels are very low, or

continue for up to five shifts or days before making a compliance or

noncompliance determination. MSHA inspection procedures require

inspectors to sample at least five occupations, if available, on each

mechanized mining unit (MMU) on the first day of sampling. The operator

is cited if the average of those measurements exceeds the applicable

standard. However, if the average falls below the standard, but one or

more of the measurements exceed it, additional samples are collected on

the subsequent production shift or day. The results of the first and

second day of sampling on all occupations are then averaged to

determine if the applicable standard is exceeded. Additionally, when an

inspector continues sampling after the first day because a previous

measurement exceeds the standard, MSHA's procedures call for all

measurements taken on a given occupation to be averaged individually

for that occupation. If the average of measurements taken over more

than one day on all occupations is equal to or less than the applicable

standard, but the average of measurements taken on any one occupation

exceeds the value in a decision table developed by MSHA (based on the

cumulative concentration for two or more samples exceeding 10.4 mg/m

\3\, which is equivalent to a 5-measurement average exceeding 2.0 mg/m

\3\), the operator is cited for exceeding the applicable standard.

B. The Spot Inspection Program (SIP)

In response to concerns about possible tampering with dust samples

in 1991, MSHA convened the Coal Mine Respirable Dust Task Group (Task

Group) to review the Agency's respirable dust program. As part of that

review, MSHA developed a special respirable dust ``spot inspection

program'' (SIP).

This program was designed to provide the Agency with information on

the dust levels to which underground miners are typically exposed.

Because of the large number of mines and MMUs (mechanized mining units)

involved and the need to obtain data within a short time frame,

respirable dust sampling during the SIP was limited to a single shift

or day, a departure from MSHA's normal sampling procedures. The term

``MMU'' is defined in 30 CFR 70.2(h) to mean a unit of mining

equipment, including hand loading equipment, used for the production of

material. As a result, MSHA decided that if the average of multiple

occupation measurements taken on an MMU during any one-day inspection

did not exceed the applicable standard the inspector would review the

result of each individual full-shift sample. If any individual full-

shift measurement exceeded the applicable standard by an amount

specified by MSHA, a citation would be issued for noncompliance,

requiring the mine operator to take immediate corrective action to

lower the average dust concentration in the mine atmosphere in order to

protect miners.

During the SIP inspections, MSHA inspectors cited violations of the

2.0 mg/m \3\ standard if either the average of the five measurements

taken on a single shift was greater than or equal to 2.1 mg/m \3\, or

any single, full-shift measurement exceeded or equaled 2.5 mg/m \3\.

Similar adjustments were made when the 2.0 mg/m \3\ standard was

reduced due to the presence of quartz dust in the mine atmosphere.

The procedures issued by MSHA's Coal Mine Safety and Health

Division during the SIP were similar to those used by the MSHA Metal/

Nonmetal Mine Safety and Health Division and

[[Page 5668]]

the Occupational Safety and Health Administration (OSHA) when

determining whether to cite based on a single, full-shift measurement.

That practice provides for a margin of error reflecting an adjustment

for uncertainty in the measurement process (i.e., sampling and

analytical error). The margin of error thus allows citations to be

issued only where there is a high level of confidence that the

applicable standard has been exceeded.

Based on the data from the SIP inspections, the Task Group

concluded that MSHA's practice of making noncompliance determinations

solely on the average of multiple-sample results did not always result

in citations in situations where miners were known to be overexposed to

respirable coal mine dust. For example, if measurements obtained for

five different occupations within the same MMU were 4.1, 1.0, 1.0, 2.5,

and 1.4 mg/m \3\, the average concentration would be 2.0 mg/m \3\.

Although the dust concentration for two occupations exceeds the

applicable standard, under MSHA procedures no citation would have been

issued nor any corrective action required to reduce dust levels to

protect miners' health. Instead, MSHA policy required the inspector to

return to the mine the next day that coal was being produced and resume

sampling in order to decide if the mine was in compliance or not in

compliance.

The Task Group also recognized that the results of the first full-

shift samples taken by an inspector during a respirable dust inspection

are likely to reflect higher dust concentrations than samples collected

on subsequent shifts or days during the same inspection. MSHA's

comparison of the average dust concentration of inspector samples taken

on the same occupation on both the first and second day of a multiple-

day sampling inspection showed that the average concentration of all

samples taken on the first day of an inspection was almost twice as

high as the average concentration of samples taken on the second day.

MSHA recognized that sampling on successive days does not always result

in measurements that are representative of everyday respirable dust

exposures in the mine because mine operators can anticipate the

continuation of inspector sampling and make adjustments in dust control

parameters or production rates to lower dust levels during the

subsequent sampling.

In response to these findings, in November 1991, MSHA decided to

permanently adopt the single shift inspection policy initiated during

the SIP.

C. The Keystone Decision

In 1991, three citations based on single, full-shift measurements

were issued under the SIP to the Keystone Coal Mining Corporation. The

violations were contested, and an administrative law judge from the

Federal Mine Safety and Health Review Commission (Commission) vacated

the citations. The decision was appealed by the Secretary of Labor to

the Commission because the Secretary believed that the administrative

law judge was in error in finding that rulemaking was required under

section 202(f) of the Mine Act for the Secretary to use single, full-

shift measurements for noncompliance determinations. In addition, the

Secretary contended that the 1971/1972 finding pertained to operator

sampling and that the SIP at issue involved only MSHA sampling. The

Commission, which affirmed the decision of the administrative law

judge, found that:

Title II [of the Mine Act] applies to both operator sampling and

to MSHA actions to ensure compliance, including sampling by MSHA.

Section 202(g) specifically provides for MSHA spot inspections.

Nothing in Sec. 202(f) or Sec. 202(g) suggests that Sec. 202(f)

applies differently to MSHA sampling. Thus, the 1971 finding, issued

for purposes of Title II, applies broadly to both MSHA and operator

sampling of the mine atmosphere.

The Commission also held that the revised MSHA policy was in

contravention of the 1971/1972 finding and could only be altered if the

requirements of the Mine Act and the Administrative Procedure Act, 5

U.S.C. 550, were met.

V. Executive Order 12866 and Regulatory Impact Analysis

MSHA has designated this joint finding as a significant action; it

has been reviewed by OMB under E.O. 12866. MSHA estimates that the

total annual costs associated with the implementation of this finding

will be $707,950, of which $446,125 will be incurred by underground

coal mines and $261,825, incurred by surface coal operations. MSHA

projects that this finding will result in reductions of future cases of

occupational lung disease and attendant cost savings. MSHA has prepared

a separate regulatory impact analysis which is available to the public

upon request.

VI. Procedural History of the Current Notices

As a result of the innovations and technological advancements

described earlier, and the decision in Keystone Coal v. Secretary of

Labor, 16 FMSHRC 6 (January 4, 1994), the Secretary of Labor and the

Secretary of Health and Human Services published a proposed joint

notice in the Federal Register on February 18, 1994 (59 FR 8357),

pursuant to sections 101 and 202(f)(2) of the Mine Act. The notice

proposed to rescind the 1971/1972 proposed and final findings by the

Secretaries of the Interior and Health, Education and Welfare, and find

that a single, full-shift measurement will accurately represent the

atmospheric conditions with regard to the respirable dust concentration

during the shift on which it was taken.

Concurrently, MSHA published a separate notice in the Federal

Register announcing its intention to use both single, full-shift

respirable dust measurements and the average of multiple, full-shift

respirable dust measurements for noncompliance determinations (59 FR

8356). That notice was published to inform the mining public of how the

Agency intended to implement its new enforcement procedure utilizing

single, full-shift samples, and to solicit public comment on the new

procedure.

The comment period on the proposed joint finding was scheduled to

close on April 19, 1994, but was extended to May 20, 1994, in response

to requests from the mining community (59 FR 16958). Subsequently,

public comments were received, including comments from both labor and

industry.

On July 6, 1994, in response to requests from the mining community,

a public hearing was held on both notices in Morgantown, West Virginia

(59 FR 29348). Also, in response to additional requests from the mining

community, a second hearing was held on July 19, 1994, in Salt Lake

City, Utah. To allow for the submission of post-hearing comments, the

record was held open until August 5, 1994.

The hearings on the proposed joint notice were conducted by a joint

MSHA/NIOSH panel. Presenters at the Morgantown hearing included

international and local representatives of the United Mine Workers of

America (UMWA), several mine operators, and a panel presentation from

the American Mining Congress (AMC) and the National Coal Association

(NCA). Presenters at the Salt Lake City hearing included the Utah

Mining Association, several mine operators, and another joint AMC/NCA

panel. The joint MSHA/NIOSH panel received prepared remarks from the

presenters and asked questions as well. The joint agency panel also

responded to questions from the presenters.

To ensure that all issues raised were fully considered, MSHA and

NIOSH conducted a thorough review of existing data, engaged in an

extensive literature

[[Page 5669]]

search, sought an independent analysis of the scientific validity of

single, full-shift measurements, and conducted additional testing.

These efforts resulted in the collection of a significant amount of

information, which was made a part of the public record on September 9,

1994 (59 FR 50007). To allow interested parties the opportunity to

review and comment on the supplemental material, the Agencies extended

the comment period from September 30 to November 30, 1994.

After the close of the comment period, the Agencies reviewed all of

the comments, data and other information submitted into the record.

Some of the commenters raised questions regarding the accuracy of

single, full-shift measurements and challenged the Agencies' estimate

of measurement imprecision inherent in sample collection and analysis.

While reviewing these issues, the Agencies concluded that the term

``accurately represent'' as used in section 202(f) needed to be defined

because of the issues which commenters raised. In response, the

Agencies reopened the record on March 12, 1996, to provide a criterion

for ``accuracy'', to supply new data and statistical analytical

analyses on the precision of coal mine respirable dust measurements

obtained using approved sampling equipment, and to allow the public to

review and submit comments on the supplemental information (61 FR

10012). In addition, the March 12 notice identified certain refinements

in MSHA's measurement process as applied to inspector samples. These

modifications, currently in place, involve the measurement of both pre-

and post-exposure filter weights to the nearest microgram on a scale

calibrated using the established procedure in MSHA's laboratory, and

discontinuing the practice of truncating the recorded weights used in

calculating the dust concentration (that is, MSHA no longer ignores

digits representing hundredths and thousandths of a milligram).

The new comment period was scheduled to close on April 11, 1996,

but was extended until June 10, 1996, in response to requests from the

mining community. Additionally, on April 11, 1996, the Agencies

announced their intention to conduct a second public hearing on the

content of the March 12 notice (61 FR 16123). On May 10, 1996, a public

hearing conducted by a joint MSHA/NIOSH panel was held in Washington,

DC. One scheduled presenter, representing the UMWA, appeared at this

hearing.

Some commenters expressed concern for the procedures used by the

Agencies in making a new finding, asserting that MSHA and NIOSH were

not complying with the rulemaking provisions of the Mine Act. These

commenters contended that the recision of the final finding and

implementation by MSHA of single, full-shift sampling can only be

effectuated through notice and comment rulemaking. These commenters

argue that because MSHA failed to appeal the Keystone case, MSHA was

bound by the Commission decision in that case which mandated notice and

comment rulemaking to rescind the prior finding and authorize use of

single samples by the Agency.

MSHA and NIOSH have considered these comments, but believe that the

process they have chosen to follow is consistent with the requirement

of section 202(f) of the Mine Act, which provides that a finding shall

be made ``in accordance with the provisions of section 101'' of the

Mine Act. Section 101 contains the procedural requirements for

promulgation of mandatory health and safety standards, including

provision for notice and comment. All interested parties were given

ample opportunity for notice and comment at every stage of

consideration of the proposed joint finding. The Agencies are not

developing, promulgating, or revising a mandatory health standard in

this notice, nor is the 2.0 mg/m \3\ respirable dust standard being

revised. Moreover, the Agencies have made a finding that the average

concentration of respirable dust in the mine atmosphere to which each

miner in the active workings of a coal mine is exposed during a shift

can be accurately measured with a single, full-shift sample. This is a

scientific finding contemplated by section 202(f) of the Mine Act.

While one commenter asserted that the Secretaries were not following

proper notice and comment procedures in section 101 [e.g., sections

101(a)(1) through (9)], the only example given by the commenter is the

fact that the notice was published in the ``Notice'' section, rather

than the ``Proposed Rules'' or ``Rules and Regulations'' section of the

Federal Register. Because this is not a mandatory safety and health

standard, there is no need for the Secretaries to publish the finding

as a proposed rule, or to address feasibility, for example, which would

be required under section 101(a)(6)(A) when a mandatory safety or

health standard is promulgated. The Secretaries have properly complied

with all the procedural elements of section 101 which apply to this

notice.

Some commenters referenced section 101(a)(9) of the Mine Act, 30

U.S.C. 811(a)(9), which provides that no mandatory standard shall

reduce the protection afforded miners by an existing standard under the

Mine Act. As stated previously, this scientific finding does not

constitute rulemaking and is not a promulgation of a mandatory health

standard. Rather, it is a ``finding'' under the Mine Act, established

in the same manner as the initial finding, in 1972, the effect of which

is to increase health protection for miners by allowing single, full-

shift measurements to be used to determine average concentrations

during a single work shift instead of continuing to rely solely on

averaging the results of several days of sampling or sampling across

various occupations on the same shift.

In MSHA's notice published on February 18, 1994 (59 FR 8356), the

Agency specifically noted that any change to the substantive procedure

for mine operator respirable dust sampling governed by MSHA regulations

would require rulemaking by MSHA.

VII. Issues Regarding Accuracy of a Single, Full-Shift Measurement

Some commenters questioned the accuracy of single, full-shift

measurements, and challenged the Secretaries' assessment of measurement

accuracy. Some commenters questioned the Secretaries' interpretation of

section 202(b) of the Mine Act, while others agreed with the

interpretation. The following issues were generally raised: the

measurement objective as defined by the Mine Act; the definition of the

term ``accurately represent'', as used in section 202(f); the validity

of the sampling process; measurement uncertainty and dust concentration

variability; and the accuracy of a single, full-shift measurement.

A. Measurement Objective

Some comments reflected a general misunderstanding of what the

Secretaries intend to measure with a single, full-shift measurement,

i.e., the measurement objective. For example, some commenters asserted

that the dust concentration that should be measured is dust

concentration averaged over a period greater than a single shift. Some

commenters noted that dust concentrations can vary during a shift and

that dust concentration is not uniform throughout a miner's work area.

In order to clarify the intent of the Secretaries, the explanation that

follows describes the elements of the measurement objective and how the

measurement objective relates to the requirements of section 202(f).

To evaluate the accuracy of a dust sampling method it is necessary

to specify the airborne dust to be measured, the time period to which

the

[[Page 5670]]

measurement applies, and the area represented by the measurement. Once

specified, these items can be combined into a measurement objective.

The measurement objective represents the goal of the sampling and

analytical method to be utilized.

1. The Airborne Dust to be Measured

Section 202(f) of the Mine Act states that ``average

concentration'' means `` * * * a determination [i.e., measurement]

which accurately represents the atmospheric conditions with regard to

respirable dust to which each miner in the active workings of a mine is

exposed.'' Later in section 202(f), the phrase ``atmospheric

conditions'' is used to refer to the concentration of respirable dust.

Therefore, the airborne dust to be measured is respirable dust. Section

202(e) defines respirable dust as the dust measured by an approved

sampler unit.

2. Time Period to Which the Measurement Applies

Section 202(b)(2) provides that each mine operator ``* * * shall

continuously maintain the average concentration of respirable dust in

the mine atmosphere during each shift to which each miner * * * is

exposed'' at or below the applicable standard. In section 202(f)

``average concentration'' is defined as an atmospheric condition

measured ``over a single shift only, unless * * * such single shift

measurement will not, after applying valid statistical techniques,

accurately represent such atmospheric conditions during such shift.''

For the purpose of this notice, the Secretaries have determined that

``atmospheric conditions'' mean the fluctuating concentration of

respirable coal mine dust during a single shift. These are the

atmospheric conditions to which a sampler unit is exposed. Therefore,

the present finding pertains only to the accuracy in representing the

average of the fluctuating dust concentration over a single shift.

3. Area Represented by the Measurement

The Mine Act gives the Secretary of Labor the discretion to

determine the area to be represented by respirable dust measurements

collected over a single shift. As articulated by the United States

Court of Appeals for the 10th Circuit in American Mining Congress (AMC)

versus Marshall, 671 F.2d 1251 (1982), the Secretary of Labor may place

the sampler unit in any area or location ``* * * reasonably calculated

to prevent excessive exposure to respirable dust.'' Because the

Secretary of Labor intends to prevent excessive exposure by limiting

dust concentration at every location in the active workings, the area

represented by any respirable dust measurement must be the sampling

location.

Some commenters identified the dust concentration to be estimated

as either the mean dust concentration over some period greater than an

individual shift, the mean dust concentration over some spatially

distributed region of the mine, or a ``grand mean'' consisting of some

combination of the above. These comments were based on the false

premise that the measurement objective in section 202(f) is something

other than the average atmospheric conditions during a single shift at

the sampling location. It is true that these mean quantities described

by some commenters cannot be accurately estimated using a single, full-

shift measurement, but the Secretaries make no claim of doing so, nor

are they required to make such considerations.

Some commenters argued that Congress intended that the measurement

objective be a long-term average. Specifically, some commenters stated

that because coal dust exposure is related to chronic health effects,

the exposure limit should be applied to dust concentrations averaged

over a miner's lifetime. These commenters identified the measurement

objective as being the dust concentration averaged over a long, but

unspecified, term and argued that a single, full-shift measurement

cannot accurately estimate this long-term average.

If the objective of section 202(b) were to estimate dust

concentration averaged over a lifetime of exposure, then the

Secretaries would agree that a single, full-shift sample, or even

multiple samples collected during a single inspection, would not

provide the basis for an accurate measurement. Section 202(b) of the

Mine Act, however, does not mention long-term averaging, rather it

explicitly requires that the average dust concentration be continuously

maintained at or below the applicable standard during each shift

(emphasis added). Furthermore, in Consolidation Coal Company versus

Secretary of Labor 8 FMSHRC 890, (1986), aff'd 824 F.2d 1071, (D.C.

Cir. 1987), the Commission found that each episode of a miner's

overexposure to respirable dust significantly and substantially

contributes to the health hazard of contracting chronic bronchitis or

coal workers' pneumoconiosis, diseases of a fairly serious nature.

Some commenters submitted evidence that dust concentrations can

vary significantly near the mining face, and that these variations may

extend into areas where miners are located. That is, the average dust

concentration over a full shift is not identical at every point within

a miner's work area. These commenters submitted several bodies of data

purporting to show significant discrepancies between simultaneous dust

concentration measurements collected within a relatively small distance

of one another. Several commenters maintained that the measurement

objective is to accurately measure the average concentration within

some arbitrary sphere about the head of the miner, and that multiple

measurements within this sphere are necessary to obtain an accurate

measurement. The Secretaries recognize that dust concentrations in the

mine environment can vary from location to location, even within a

small area near a miner. As mentioned earlier, the Mine Act does not

specify the area that the measurement is supposed to represent, and the

sampler unit may therefore be placed in any location reasonably

calculated to prevent excessive exposure to respirable dust.

Several commenters suggested that the measurement objective should

be a miner's ``true exposure'' or what the miner actually inhales. The

Secretaries do not intend to use a single, full-shift measurement to

estimate any miner's ``true exposure,'' because no sampling device can

exactly duplicate the particle inhalation and deposition

characteristics of a miner at any work rate (these characteristics

change with work rate), let alone at the various work rates occurring

over the course of a shift. Section 202(a) of the Mine Act, however,

refers to ``the amount of respirable dust in the mine atmosphere to

which each miner in the active workings of such mine is exposed''

measured ``* * * at such locations * * *'' as prescribed by the

Secretary of Labor. It is sufficient for the purposes of the Mine Act

that the sampler unit accurately represent the amount of respirable

dust at such locations only.

Accordingly, the Secretaries define the measurement objective to be

the accurate determination of the average atmospheric conditions, or

concentration of respirable dust, at a sampling location over a single

shift.

B. Accuracy Criterion

A ``single shift measurement'' means the calculated dust

concentration resulting from a valid single, full-shift sample of

respirable coal mine dust. In reviewing the various issues raised by

commenters, the Agencies found that the term ``accurately represent,''

as used

[[Page 5671]]

in section 202(f) in connection with a single shift measurement, was

not defined in the Mine Act. Therefore, in their March 12, 1996 notice,

the Secretaries proposed to apply an accuracy criterion developed and

adopted by NIOSH in judging whether a single, full-shift measurement

will ``accurately represent'' the full-shift atmospheric dust

concentration. This criterion requires that measurements come within 25

percent of the corresponding true dust concentration at least 95

percent of the time [1].

One commenter opposed the application of the NIOSH Accuracy

Criterion since it ignores environmental variability. For reasons

explained above, the Secretaries have restricted the measurement

objective to an individual shift and sampling location. Therefore,

environmental variability beyond what occurs at the sampling location

on a single shift is not relevant to assessing measurement accuracy.

For over 20 years, the NIOSH Accuracy Criterion has been used by

NIOSH and others in the occupational health professions to validate

sampling and analytical methods. This accuracy criterion was devised as

a goal for the development and acceptance of sampling and analytical

methods capable of generating reliable exposure data for contaminants

at or near the Occupational Safety and Health Administration's (OSHA)

permissible exposure limits.

OSHA has frequently employed a version of the NIOSH Accuracy

Criterion when issuing new or revised single substance standards. For

example, OSHA's benzene standard provides: ``[m]onitoring shall be

accurate, to a confidence level of 95 percent, to within plus or minus

25 percent for airborne concentrations of benzene''(29 CFR

1910.1028(e)(6)). Similar wording can be found in the OSHA standards

for vinyl chloride (29 CFR 1917), arsenic (29 CFR 1918), lead (29 CFR

1925), 1,2-dibromo-3-chloropropane (29 CFR 1044), acrylonitrile (29 CFR

1045), ethylene oxide (29 CFR 1047), and formaldehyde (29 CFR 1048).

Note that for vinyl chloride and acrylonitrile, the accuracy criteria

for the method is 35 percent at 95 percent confidence at

the permissible exposure limit.

Some commenters contended that the NIOSH Accuracy Criterion does

not conform with international standards recently adopted by the

European Committee for Standardization (CEN) [2]. Contrary to these

assertions, the NIOSH Accuracy Criterion not only conforms to the CEN

criterion but is, in fact, more stringent. The CEN criterion requires

that 95 percent of the measurements fall within 30 percent

of the true concentration, compared to 25 percent under the

NIOSH criterion. Consequently, any sampling and analytical method that

meets the NIOSH Accuracy Criterion will also meet the CEN criterion.

The NIOSH Accuracy Criterion is relevant and widely recognized and

accepted in the occupational health professions. Further, commenters

proposed no alternative criteria for accuracy. Accordingly, for

purposes of section 202(f) of the Mine Act, the Secretaries consider a

single, full-shift measurement to ``accurately represent'' atmospheric

conditions at the sampling location, if the sampling and analytical

method used meets the NIOSH Accuracy Criterion.

Several commenters suggested that method accuracy should be

determined under actual mining conditions rather than in a laboratory

or in a controlled environment. Although the NIOSH Accuracy Criterion

does not require field testing, it recognizes that field testing ``does

provide further test of the method.'' However, in order to avoid

confusing real differences in dust concentration with measurement

errors when testing is done in the field, ``precautions may have to be

taken to ensure that all samplers are exposed to the same

concentrations'' [1]. Similarly, the CEN criterion for method accuracy

specifies that ``testing of a procedure shall be carried out under

laboratory conditions.'' To determine, so far as possible, the accuracy

of its sampling and analytical method under actual mining conditions,

MSHA conducted 22 field tests in an underground coal mine. To provide a

valid basis for assessing accuracy, 16 sampler units were exposed to

the same dust concentration during each field test using a specially

designed portable chamber. The data from these field experiments were

used by NIOSH in its ``direct approach'' to determining whether or not

MSHA's method meets the long-established NIOSH Accuracy Criterion. (See

section VII.E.2. of this notice).

In response to the March 12, 1996 notice, a commenter claimed that

the supplementary information and analyses introduced into the public

record by that notice addressed the precision of a single, full-shift

measurement rather than its accuracy. According to this commenter, by

focusing on precision, important sources of systematic error had been

overlooked. The Secretaries agree with the comment that precision is

not the same thing as accuracy. The accuracy of a measurement depends

on both precision and bias [1,3]. Precision refers to consistency or

repeatability of results, while bias refers to a systematic error that

is present in every measurement. Since the NIOSH Accuracy Criterion

requires that measurements consistently fall within a specified

percentage of the true concentration, the criterion covers both

precision and uncorrectable bias.

Since the amount of dust present on a filter capsule used by an

MSHA inspector is measured by subtracting the pre-exposure weight from

the post-exposure weight determined in the same laboratory, any bias in

the weighing process attributable to the laboratory is mathematically

canceled out by subtraction. Furthermore, as will be discussed later, a

control (i.e., unexposed) filter capsule will be pre-and post-weighed

along with the exposed filter capsules. The weight gain of the exposed

capsule will be adjusted by the weight gain or loss of the control

filter capsule. Therefore, any bias that may be associated with day-to-

day changes in laboratory conditions or introduced during storage and

handling of the filter capsules is also mathematically canceled out.

Moreover, the concentration of respirable dust is effectively defined

by section 202(e) of the Mine Act and the implementing regulations in

30 CFR parts 70, 71, and 90 to be whatever is measured with an approved

sampler unit after multiplication by the MRE-equivalent conversion

factor prescribed by the Secretary of Labor. Therefore, the Secretaries

have concluded that the improved sampling and analytical method is

statistically unbiased. This means that such measurements contain no

systematic error. It should also be noted that since any systematic

error would be present in all measurements, measurement bias cannot be

reduced by making multiple measurements. Other comments regarding

measurement bias are addressed in Appendix A.

For unbiased sampling and analytical methods, a standard

statistic--called the coefficient of variation (CV)--is used to

determine if the method meets the NIOSH Accuracy Criterion. The CV,

which is expressed as either a fraction (e.g., 0.05) or a percentage

(e.g., 5 percent), quantifies measurement accuracy for an unbiased

method. An unbiased method meets the NIOSH Accuracy Criterion if the

``true'' CV is no more than 0.128 (12.8 percent). However, since it is

not possible to determine the true CV with 100-percent confidence, the

NIOSH Accuracy Criterion contains the additional requirement that there

be 95-percent confidence that measurements by the method will come

within 25 percent of

[[Page 5672]]

the true concentration 95 percent of the time. Stated in mathematically

equivalent terms, an unbiased method meets the NIOSH Accuracy Criterion

if there is 95-percent confidence that the true CV is less than or

equal to 0.128 (12.8 percent).

C. Validity of the Sampling Process

A single, full-shift measurement of respirable coal mine dust is

obtained with an approved sampler unit, which is either worn or carried

by the miner directly to and from the sampling location and is operated

portal to portal. The unit remains operational during the entire shift

or for eight hours, whichever time is less. A portable, battery-powered

pump draws dust-laden mine air at a flow rate of 2 liters per minute

(L/min) through a 10-mm nylon cyclone, a particle-size selector that

removes non-respirable particles from the airstream. Non-respirable

particles are particles that tend to be removed from the airstream by

the nose and upper respiratory airways. These particles fall to the

bottom of the cyclone body called the ``grit pot,'' while smaller,

respirable particles (of the size that would normally enter into the

lungs) pass through the cyclone, directly into the inlet of the filter

cassette. This airstream is directed through the pre-weighed filter

leaving the particles deposited on the filter surface. The collection

filter is enclosed in an aluminum capsule to prevent leakage of sample

air around the filter and the loss of any dust dislodged due to impact.

The filter capsule is sealed in a protective plastic enclosure, called

a cassette, to prevent contamination. After completion of sampling, the

filter cassette is sent to MSHA's Respirable Dust Processing Laboratory

in Pittsburgh, Pennsylvania, where it is weighed again to determine the

weight gain in milligrams, which is the amount of dust collected on the

filter. The concentration of respirable dust, expressed as milligrams

per cubic meter (mg/m\3\ ) of air, is determined by dividing the weight

gain by the volume of mine air passing through the filter and then

multiplying this quantity by a conversion factor (discussed below in

Appendix A) prescribed by the Secretary.

Some comments generally addressed the quality and reliability of

the equipment used for sampling. Specific concerns were expressed about

the quality of filter cassettes and the reliability, due to their age

and condition, of sampling pumps used by MSHA inspectors. Other

commenters questioned the effect of sampling and work practices on the

validity of a sample.

The validity of the sampling process is an important aspect of

maintaining accurate measurements. Since passage of the Coal Act, there

has been an ongoing effort by MSHA and NIOSH to improve the accuracy

and reliability of the entire sampling process. In 1980, MSHA issued

new regulations revising sampling, maintenance and calibration

procedures in 30 CFR parts 70, 71, and 90. These regulatory provisions

were designed to minimize human and mechanical error and ensure that

samples collected with approved sampler units in the prescribed manner

would accurately represent the full-shift, average atmospheric dust

concentration at the location of the sampler unit. These provisions

require: (1) Certification of competence of all individuals involved in

the sampling process and in maintaining the sampling equipment; (2)

calibration of each sampler unit at least every 200 hours; (3)

examination, testing, and maintenance of units before each sampling

shift to ensure that the units are in proper working order; and (4)

checking of sampler units during sampling to ensure that they are

operating properly and at the proper flow rate. In addition,

significant changes, such as robotic weighing using electronic balances

were made in 1984, 1994, and 1995 that improved the reliability of

sample weighings at MSHA's Respirable Dust Processing Laboratory. These

changes are discussed below in section C.3.

All of these efforts improved the accuracy and reliability of the

sampling process since the time of the 1971/1972 proposed and final

findings. A discussion follows concerning the three elements which

constitute the sampling process: sampler unit performance, collection

procedures, and sample processing.

1. Sampler Unit Performance

In accordance with the provisions of section 202(e) of the Mine

Act, NIOSH administers a comprehensive certification process under 30

CFR part 74 to approve dust sampler units for use in coal mines. To be

approved for use, a sampler unit must meet stringent technical and

performance requirements governing the quantity of respirable dust

collected and flow rate consistency over an 8-hour period when operated

at the prescribed flow rate. NIOSH also conducts annual performance

audits of approved sampler units purchased on the open market to

determine if the units are being manufactured in accordance with the

specifications upon which the approval was issued.

The system of technical and quality assurance checks currently in

place is designed to prevent a defective sampler unit from being

manufactured and made commercially available to the mining industry or

to MSHA. In the event these checks identify a potential problem with

the manufacturing process, the system requires immediate action to

identify and correct the problem.

In 1992, NIOSH approved the use of new tamper-resistant filter

cassettes with features that enhanced the integrity of the sample

collected. A backflush valve was incorporated into the outlet of the

cassette, preventing reverse airflow through the filter cassette, and

an internal flow diverter was added to the filter capsule, reducing the

possibility of dust dislodged from the filter surface falling out of

the capsule inlet.

Several commenters questioned the quality of the filter cassettes

used in the sampling program, expressing concern about whether the

cassettes always meet MSHA specifications. These concerns primarily

involve filter-to-foil distance and floppiness of the filters, which

are manufacturing characteristics not related to part 74 performance

requirements. The Secretaries believe that such characteristics have no

effect on the accuracy of a single, full-shift measurement because,

unlike the part 74 requirements, they would not affect the amount of

dust deposition.

Commenters also questioned the condition of sampling pumps used by

MSHA inspectors, stating that many of the pumps are 10 to 20 years old

and are not maintained as well as they could be. They claimed that the

age and condition of these pumps call into question not only whether

the sampling equipment could meet part 74 requirements if tested, but

also the accuracy of the measurement.

This concern is unwarranted. In 1995, MSHA replaced all pumps in

use by inspectors with new constant-flow pumps that incorporate the

latest technology in pump design. These pumps provide more consistent

flow throughout the sampling period. In addition to using new pumps,

MSHA inspectors are required to make a minimum of two flow rate checks

to ensure that the sampler unit is operating properly. The sample is

voided if the proper flow rate was not being maintained during the

final check at the conclusion of the sampling shift. Units found not

meeting the requirements of part 74 are immediately repaired, adjusted,

or removed from service. Nevertheless, MSHA recognizes that as these

pumps age, deterioration of the performance of older pumps could become

a concern. However, there is no

[[Page 5673]]

evidence that the age of the equipment affects its operational

performance if the equipment is maintained as prescribed by 30 CFR

parts 70, 71, and 90.

Some commenters suggested that the accuracy of a dust sample may be

compromised when a miner is operating equipment, due to vibration from

the machinery. The potential effect of vibration on the accuracy of a

respirable dust measurement was recognized by NIOSH in 1981. An

investigation, supported by NIOSH, was conducted by the Los Alamos

National Laboratory which found that vibration has an insignificant

effect on sampler performance [4].

2. Sample Collection Procedures

MSHA regulations at 30 CFR parts 70, 71, and 90 prescribe the

manner in which mine operators are to take respirable dust samples. The

collection procedures are designed to ensure that the samples

accurately represent the amount of respirable dust in the mine

atmosphere to which miners are exposed on the shift sampled. Samples

taken in accordance with these procedures are considered to be valid.

Several commenters questioned the effects of sampling and work

practices on the validity of a sample. Instances were cited where the

sampling unit was accidentally dropped, with the potential for the

sample to become contaminated. Commenters also pointed out that work

activities requiring crawling, duck walking, bending, or kneeling could

cause the sampling hose to snag. Such activities could also cause the

sampling head assembly to be impacted or torn off a person's garment,

possibly contaminating the sample. These commenters stated that sampler

units are sometimes treated harshly while being worn by miners,

mishandled when being transferred from one miner to another, or handled

casually at the end of a work shift.

These commenters maintained that it is impossible for MSHA

inspectors or mine operators to continuously observe collection of a

sample in order to ensure its validity, and that, for this reason, the

reliability and accuracy of the sampling equipment, when used under

actual mining conditions, is not the same as when tested and certified

in a laboratory. Averaging multiple samples would, according to these

commenters, provide some ``leeway'' in the system, by reducing the

impact of an aberrant sample.

While MSHA and NIOSH agree that it is not possible to continuously

observe the collection of each sample, MSHA inspectors are normally in

the general vicinity of the sampling location, and therefore have

knowledge of the specific conditions under which samples are taken. In

addition, MSHA inspectors are instructed to ask miners wearing the

sampler units whether anything that could affect the validity of the

sample had occurred during the shift.

Other commenters expressed concern that, if special dust control

measures are in effect during sampling, a single, full-shift

measurement may fail to represent atmospheric conditions during shifts

when samples are not collected. The Secretaries believe that this

concern is beyond the scope of this notice, which, as described in the

discussion of measurement objective, deals solely with the accuracy of

a measurement in representing atmospheric conditions on the shift being

sampled. One commenter recommended that MSHA, NIOSH, or the Bureau of

Mines (now a part of NIOSH) should evaluate the need for standardizing

the MSHA respirable dust sampling procedures. In fact, the procedures

for respirable dust sampling are already standardized under the revised

1980 MSHA regulations codified at 30 CFR parts 70, 71 and 90.

MSHA inspectors will also begin using control filter capsules to

eliminate any bias that may be associated with day-to-day changes in

laboratory conditions or introduced during storage and handling of the

filter capsules. A control filter capsule is an unexposed filter

capsule that was pre-weighed on the same day as the filter capsules

used during a sampling inspection. These control filter capsules will

be carried by the inspector, but will remain plugged and not be exposed

to the mine environment.

3. Sample Processing

Sample processing consists of weighing the filter capsules,

recording the weight gains, and examining certain samples in order to

verify their validity. Sample processing also includes electronic

transmission of the results to MSHA's computer center where dust

concentrations are computed. The results are then distributed to MSHA

enforcement personnel and to mine operators.

(a) Weighing and recording procedures. One commenter cited a

personal experience in which anomalies were noted in the pre-exposed

weights recorded by the dust cassette manufacturer. The commenter was

concerned that such anomalies indicated poor quality control in the

manufacturer's weighing process, implying that this would cause a

significant number of single, full-shift measurements to be inaccurate.

The procedures and analytical equipment used by MSHA to process

respirable coal mine dust samples have improved since 1970. From 1970

to 1984, samples were manually weighed using semimicro balances. In

1984, the process was automated with a state-of-the-art robotic system

and electronic balances, which increased the precision of sample weight

determinations. Weighing precision was further improved in 1994, when

both the robotic system and balance were upgraded.

The full benefit of the 1994 improvements of the weighing system

for inspector samples was, however, not fully attained until mid-1995,

when MSHA implemented two modifications to its procedures for

processing inspector samples. One modification involved measuring both

the pre- and post-exposed weights to the nearest microgram (0.001 mg)

on a balance calibrated using the established procedure within MSHA's

laboratory. Prior to mid-1995, filter capsules had been weighed in the

manufacturer's laboratory before sampling, and then in MSHA's

laboratory after sampling. MSHA is now pre-weighing all such filter

capsules in its own laboratory, which will significantly reduce the

potential for anomalous pre-exposed weights of filter capsules used by

inspectors. To maintain the integrity of these pre-exposed weights,

eight percent of all capsules are systematically weighed a second time.

If a significant deviation is found, the balance is recalibrated and

all filter capsules with questionable weights are reweighed.

The other modification was to discontinue the practice of

truncating the recorded weights used in calculating dust concentration.

This means that MSHA no longer ignores digits representing hundredths

and thousandths of a milligram when processing inspector samples. These

modifications improved the overall accuracy of the measurement process.

To eliminate the potential for any bias that may be associated with

day-to-day changes in laboratory conditions or introduced during

storage and handling of the filter capsules, MSHA will use control

filter capsules in its enforcement program. Any change in weight of the

control filter capsule will be subtracted from the change in weight of

the exposed filter capsule.

(b) Sample validity checks. All respirable dust samples collected

and submitted as required by 30 CFR parts 70, 71, and 90 are considered

valid unless a questionable appearance of the filter capsule or other

special circumstances are noted that would

[[Page 5674]]

cause MSHA to examine the sample further. Several commenters expressed

concern about the potential contamination of samples with ``oversize

particles.'' Such contamination, according to one commenter, can result

in aberrational weight gains. These commenters noted that current

procedures do not systematically ensure that samples collected by MSHA

contain no oversize particles. It was recommended that MSHA analyze,

for the presence of oversize particles, any dust sample that exceeds

the applicable dust standard. Also suggested for such an analysis was

any sample with a weight gain significantly different from other

samples taken in the same area.

Standard laboratory procedures, involving visual, and microscopic

examination as necessary, are used to verify the validity of samples.

Samples weighing 1.4 milligrams (mg) or more are examined visually and

microscopically, as necessary, for abnormalities such as the presence

of large dust particles (which can occur from agglomeration of smaller

particles), abnormal discoloration, abnormal dust deposition pattern on

the filter, or any apparent contamination by materials other than

respirable coal mine dust. Also examined are samples weighing 0.1 mg or

less for insufficient dust particle count. Similar checks are also

performed in direct response to specific inspector or operator concerns

noted on the dust data card to which each sample is attached.

The commenters' concerns about the contamination of samples with

oversize particles are based on the assumption that all oversize

particles, defined as dust particles greater than 10 micrometers in

size, are not respirable and therefore should be totally excluded from

any sample taken with an approved sampler unit. In fact, it has long

been known that particles greater then 10 micrometers in size can be

inhaled, and that some of these particles can reach the alveoli of the

lungs [5]. According to the British National Coal Board, ``particles as

large as 20 microns (i.e. micrometers) mean diameter may be deposited,

although most ``lung dust'' lies in the range below 10 microns

diameter'' [6]. Furthermore, it is known that, due to the irregular

shapes of dust particles, the respirable dust collected by the MRE

instrument (the dust sampler used by the British Medical Research

Establishment in the epidemiological studies on which the U.S. coal

dust standard was based) may include some dust particles as large as 20

micrometers [6]. Moreover, MSHA studies have shown that nearly all

samples taken with approved sampler units, even when operated in the

prescribed manner, contain some oversize particles [7]. Since section

202(e) of the Mine Act defines concentration of respirable dust to be

that measured by an approved sampler unit, and because the approved

sampler unit will collect some oversize particles, the Secretaries do

not consider a sample to be ``contaminated'' because it contains some

oversize particles.

The Secretaries recognize that there are occasions when oversize

particles can properly be considered a contaminant. For example, an

excessive number of such particles could be introduced into the filter

capsule if the sampling head assembly is accidentally or deliberately

turned upside down or ``dumped'' (possibly causing some of the contents

of the cyclone grit pot to be drawn into the filter capsule), if the

pump malfunctions, or if the entire sampler unit is dropped. When MSHA

has reason to believe that such contamination has occurred, the suspect

sample is examined to verify its validity.

Contrary to the assertions of some commenters, checking for

oversize particles is not standard industrial hygiene practice.

Nevertheless, MSHA checks any dust sample suspected of containing an

excessive number of oversize particles. MSHA's laboratory procedures

require any sample exhibiting an excessive weight gain (over 6 mg) or

showing evidence of being ``dumped'' to be examined for the presence of

an excessive number of oversize particles. Samples identified by an

inspector or mine operator as possibly contaminated are also examined.

If this examination indicates that the sample contains an excessive

number of oversize particles according to MSHA's established criteria,

then that sample is considered to be invalid, and is voided and not

used. In fiscal year 1996, only 83 samples or 0.4 percent of the 20,331

inspector samples processed were found to contain an excessive number

of oversize particles and thus were not used.

While rough handling of the sampler unit or an accidental mishap

could conceivably cause a sample weighing less than 6 mg to become

contaminated, as claimed by some commenters, studies show that short-

term accidental inclinations of the cyclone will not affect respirable

mass measurements made with currently approved sampler units [8].

Sampler units currently used are built to withstand the rigors of the

mine environment, and are therefore less susceptible to contamination

than suggested by some commenters. In any event, the Secretaries

believe that the validity checks currently in place, as discussed

above, will detect such samples.

D. Measurement Uncertainty and Dust Concentration Variability

Overall variability in measurements collected on different shifts

and sampling locations results from the combination of errors

associated with the measurement of a particular dust concentration and

variability in dust concentration. Variability in dust concentration

refers to the differing atmospheric conditions experienced on different

shifts or at different sampling locations. Measurement uncertainty, on

the other hand, refers to the differing measurement results that could

arise, at a given sampling location on a given shift, because of

potential sampling and analytical errors.

Numerous commenters identified sources of measurement uncertainty

and dust concentration variability that they believed should be

considered when determining whether or not a measurement accurately

represents such atmospheric conditions. Because the measurement

objective is to accurately represent the average dust concentration at

the sampling location over a single shift, it does not take into

consideration dust concentration variability between shifts or

locations. Sources of dust concentration variability will not be

considered by the Secretaries in determining whether a measurement is

accurate. Consequently, the Secretaries have concluded that the only

sources of variability relevant to establishing accuracy of a single,

full-shift measurement for purposes of section 202(f) of the Mine Act

are those related to sampling and analytical error.

1. Sources of Measurement Uncertainty

Filter capsules are weighed prior to sampling. After a single,

full-shift sample is collected, the filter capsule is weighed a second

time, and the weight gain (g) is obtained by subtracting the pre-

exposure weight from the post-exposure weight, which will then be

adjusted for the weight gain or loss observed in the control filter

capsule. A measurement (x) of the atmospheric condition sampled is then

calculated by Equation 1:

[GRAPHIC] [TIFF OMITTED] TN31DE97.000

where: x is the single, full-shift dust concentration measurement (mg/m

\3\);

1.38 is a constant MRE-equivalent conversion factor;

[[Page 5675]]

g is the observed weight gain (mg) after adjustment for the control

filter capsule;

v is the estimated total volume of air pumped through the filter

during a typical full shift.

The Secretaries recognize that random variability, inherent in any

measurement process, may cause x to deviate either above or below the

true dust concentration. The difference between x and the true dust

concentration is the measurement error, which may be either positive or

negative. Measurement uncertainty arises from a combination of

potential errors in the process of collecting a sample and potential

errors in the process of analyzing the sample. These potential errors

introduce a degree of uncertainty when x is used to represent the true

dust concentration.

The statistical measure used by the Secretaries to quantify

uncertainty in a single, full-shift measurement is the total sampling

and analytical coefficient of variation, or CVtotal.

CVtotal quantifies the magnitude of probable sampling and

analytical errors and is expressed as either a fraction (e.g., 0.05) or

as a percentage (e.g., 5 percent) of the true concentration. For

example, if a single, full-shift measurement (x) is collected in a mine

atmosphere with true dust concentration equal to 1.5 mg/m \3\, and the

standard deviation of potential sampling and analytical errors

associated with x is equal to 0.075 mg/m \3\, the uncertainty

associated with x would be expressed by the ratio of the standard

deviation to the true dust concentration: CVtotal = 0.075/

1.5 = 5 percent.

Based on a review of the scientific literature, the Secretaries in

their March 12, 1996 notice, identified three sources of uncertainty in

a single, full-shift measurement, which together make up

CVtotal:

(1) CVweight--variability attributable to weighing

errors or handling associated with exposed and control filter capsules.

This covers any variability in the process of weighing the exposed or

control filter capsules prior to sampling (pre-weighing), assembling

the exposed and control filter cassettes, transporting the filter

cassettes to and from the mine, and weighing the exposed and control

filter capsules after sampling (post-weighing).

(2) CVpump--variability in the total volume of air

pumped through the filter capsule. This covers variability associated

with calibration of the pump rotameter,2 variability in

adjustment of the flow rate at the beginning of the shift, and

variation in the flow rate during sampling. It should be noted that

variation in flow rate during sampling was identified as a separate

component of variability in MSHA's February 18, 1994, notice. Here, it

is included within CVpump.

---------------------------------------------------------------------------

\2\ The rotameter consists of a weight or ``float'' which is

free to move up and down within a vertical tapered tube which is

larger at the top than the bottom. Air being drawn through the

filter cassette passes through the rotameter, suspending the

``float'' within the tube. The pump is ``calibrated'' by drawing air

through a calibration device (usually what is known as a bubble

meter)at the desired flow rate and marking the position of the float

on the tube. The processes of marking the position on the tube

(laboratory calibration) and adjusting the pump speed in the field

so that the float is positioned at the mark are both subject to

error.

---------------------------------------------------------------------------

(3) CVsampler--variability in the fraction of dust

trapped on the filter. This is attributable to physical differences

among cyclones. This component was introduced in the material submitted

into the record in September 1994.

These three components of measurement uncertainty can be combined

to form an indirect estimate of CVtotal by means of the

standard propagation of errors formula:

[GRAPHIC] [TIFF OMITTED] TN31DE97.001

These three components are discussed in greater detail, along with

responses to specific comments, in Appendix B.

2. Sources of Dust Concentration Variability

Numerous commenters also raised issues related to sources of dust

concentration variability. Some of these commenters maintain that the

Secretaries should include in CVtotal additional components

representing the effects of shift-to-shift variability and variability

related to location (spatial variability). These comments reflect a

misunderstanding of the measurement objective as intended by the Mine

Act (see section VII.A. of this notice).

Exposure variability due to job, location, shift, production level,

effectiveness of engineering controls, and work practices will be

different from mine to mine, and is under the control of the mine

operator. The sampler unit is not intended to account for these

factors.

(a) Spatial variability. Several commenters stated that

CVtotal should account for spatial variability, or the

differences in concentration related to location. The Secretaries agree

that dust concentrations vary between locations in a coal mine, even

within a relatively small area. However, real variations in

concentration between locations, while sometimes substantial, do not

contribute to measurement error. As stated earlier, the measurement

objective is to accurately measure average atmospheric conditions, or

concentration of respirable dust, at a sampling location over a single

shift.

(b) Shift-to-shift variability. Several commenters stated that

CVtotal should take into account the differences or

variations in dust concentration that occur shift to shift. Although

the Secretaries agree that dust concentrations vary from shift to

shift, the measurement objective is to measure average atmospheric

conditions on the specific shift sampled. This result is consistent

with the Mine Act, which requires that concentrations of respirable

mine dust be maintained at or below the applicable standard during each

shift.

3. Other Factors Considered

(a) Proportion of oversize particles. Several commenters expressed

concern that respirable dust cyclones are handled in a rough manner in

normal use and occasionally turned upside down. According to one

commenter, this type of handling would cause more large particles to be

deposited on the filter in the mine environment than when used in the

laboratory. This commenter knew of no data that could be used to

evaluate the error associated with such occurrences and recommended

that a study be commissioned to measure the proportion of non-

respirable particles on the filters after they are weighed to MSHA

standards.

After considering this recommendation, the Secretaries have

concluded that the available evidence shows that short-term

inclinations of the cyclone, as might frequently occur during sampling,

will not affect respirable dust measurements made with approved sampler

units [8]. The weight of the sampler head assembly makes it extremely

unlikely that a

[[Page 5676]]

sampler unit could be turned upside down in normal use. Furthermore,

with a field study of the type recommended, variability in the field

measurements due to normal handling would be confounded with

variability due to real differences in atmospheric conditions.

Therefore, the Secretaries believe that such a study would not be

useful in establishing variability in measurements due to differences

in handling of the sampler unit.

(b) Anomalous events. Several commenters asserted that

unpredictable, infrequent events, such as a ``face blowout'' on a

longwall (a violent expulsion of coal together with large quantities of

coal dust and/or methane gas) or high winds at a surface mine, can

cause rapid loading of a filter capsule and thereby distort a

measurement to show an excessive dust concentration based on a single,

full-shift sample when, they argue, the dust standard had not been

exceeded. In fact, if such an occurrence were to cause a measurement

above the applicable standard, the dust standard would in fact be

violated. No evidence was presented to demonstrate that short-term high

exposures can overload a dust sampling filter or cause the sampling

device to malfunction. Nor was evidence presented to demonstrate that

miners are not also exposed to the same high dust concentrations as the

sampler unit when such events occur. The Secretaries conclude that such

events are results of the dynamic and ever-changing mine environment--

an environment to which the miner is exposed. The sampler unit is

designed to measure the atmospheric condition at a specific sampling

location over a full shift. If such events occur, the sampler unit will

accurately record the atmospheric condition to which it is exposed.

(c) Conversion factor used in the dust concentration calculation.

Several commenters questioned the 1.38 MRE-conversion factor used in

Equation 1. This factor is used to convert a measurement obtained with

the type of dust sampler unit currently approved for use in coal mines

to an equivalent concentration as measured with an MRE gravimetric dust

sampler. The term ``MRE instrument'' is defined in 30 CFR Sec. 70.2(I).

The conversion factor is necessary because the coal mine dust standard

was derived from British data collected with an MRE instrument, which

collects a larger fraction of coal mine dust than does the approved

dust sampling unit [9]. The 1.38 constant has been established by the

Secretaries as applying to the currently approved dust sampler unit

described in 30 CFR part 74.

Some commenters contended that variability involved in the data

analysis used in establishing the conversion factor should be taken

into account in determining CVtotal. This suggestion

demonstrates a misunderstanding of the difference between measurement

imprecision and measurement bias. The 1.38 factor applies to every

sampler unit currently approved under part 74. Since the same

conversion factor is applied to every measurement, any error in the

value used would cause a measurement bias but would have no effect on

measurement imprecision. Since Congress defined respirable dust in

section 202(e) of the Mine Act as whatever is collected by a currently

approved sampler unit, a measurement incorporating the 1.38 factor is

unbiased by definition. Further discussion is provided in Appendix A on

why use of the 1.38 factor does not introduce a bias. Appendix A also

addresses comments relating to other aspects of the 1.38 conversion

factor; comments regarding the fact that MSHA's sampler unit does not

conform to other definitions of respirable dust; and questions

concerning the effect of static charge on sampler unit performance.

(d) Reduced dust standards. One commenter pointed out that in

estimating CVtotal, MSHA and NIOSH did not take into account

any potential errors associated with silica analysis. The commenter

argued that since silica analysis is used to establish reduced dust

standards, MSHA and NIOSH had failed to demonstrate ``* * * accuracy

for all samples `across the range of possible reduced dust standards.'

''

This commenter confuses the accuracy of a respirable dust

concentration measurement with the accuracy of the procedure used to

establish a reduced dust standard. MSHA has a separate program in which

silica analysis is used to set the applicable respirable coal mine dust

standard, in accordance with section 205 of the Mine Act, when the

respirable dust in the mine atmosphere of the active workings contains

more than 5 percent quartz. As shown by Equation 1, no silica analysis

is used in a single, full-shift measurement of the respirable dust

concentration. Therefore, the Secretaries do not agree with the comment

that CVtotal should include a component representing

potential errors in silica analysis.

(e) Dusty clothing. Several commenters pointed out that local

factors such as dusty clothing could cause concentrations in the

immediate vicinity of the sampler unit to be unrepresentative of a

larger area. Dust from a miner's clothing nevertheless represents a

potential hazard to the miner. No evidence was presented to demonstrate

that miners are not also exposed to dust originating from dusty

clothing.

E. Accuracy of a Single, Full-Shift Measurement

1. Quantification of Measurement Uncertainty

Several commenters argued that MSHA underestimated

CVtotal in its February 18, 1994 notice and suggested

alternative estimates ranging from 16 to 50 percent. These commenters

cited several published studies and submitted five sets of data in

support of these higher estimates. Statistical analyses of the data

were also submitted.

MSHA and NIOSH reviewed all of the studies referenced by the

commenters. The review showed that all of the estimates of measurement

variability were from studies carried out prior to improvements

mandated by the 1980 MSHA revisions to dust sampling regulations,

discussed earlier in ``Validity of the Sampling Process.'' For example,

the General Accounting Office (GAO) 3 and the National

Bureau of Standards (NBS, now the National Institute of Standards and

Technology) studies were conducted in 1975. The National Academy of

Sciences report, which analyzed the same data as the NBS and GAO

reports, was issued in 1980. The review further showed that the

measurement variability quantified in these studies included effects of

spatial variability--a component of variability the Secretaries

deliberately exclude when determining the accuracy of a sampling and

analytical method as discussed in section D.2.(a). Additionally, since

past studies frequently relied on combining estimates of variability

components obtained from different bodies of data, some of them also

suffered from methodological problems related to combining individual

sources of uncertainty. For example, in 1984, a NIOSH study identified

several conceptual errors in earlier studies that had led to double-or

even triple-counting of some variability components [10].

---------------------------------------------------------------------------

\3\ Many of the recommendations in the GAO report were later

adopted and implemented by MSHA.

---------------------------------------------------------------------------

Although all the data and analyses submitted by commenters included

effects of spatial variability, one of these data sets, consisting of

paired sample results, contained sufficient information to indicate

that weighing imprecision

[[Page 5677]]

was less than what MSHA had assumed in its February 18, 1994 notice.

However, without an independent estimate of spatial variability

applicable to these samples, it is not mathematically possible to

utilize this data set to estimate variability attributable to the

sampler unit or the volume of air sampled. A second data set consisted

only of differences in dust concentration between paired samples,

making it impossible to use it even for evaluating weighing

imprecision. The remaining three data sets included effects of shift-

to-shift variability, which, like spatial variability, is not relevant

to the measurement objective. Therefore, none of these data could be

used to estimate overall measurement imprecision. Further details are

provided in Appendix C.

One of the commenters particularly questioned the value MSHA used

in its February 18, 1994 notice to represent variability in initially

setting the pump flow rate. In response to this commenter's suggestion,

MSHA conducted a study to verify the magnitude of this variability

component. This study simulated flow rate adjustment under realistic

operating conditions by including a number of persons checking and

adjusting initial flow rate under various working situations [11].

Results showed the coefficient of variation associated with the initial

flow rate adjustment to be 30.5 percent, which is less than

the 5-percent value used by MSHA in the February 1994 notice. In

addition, based on a review of published results, the Secretaries have

concluded that the component of uncertainty associated with the

combined effects of variability in flow rate during sampling and

potential errors in calibration is actually less than 3 percent. As

explained in Appendix B, these two sources of uncertainty can be

combined to estimate CVpump. After reviewing the available

data and the comments submitted, the Secretaries have concluded that

the best estimate of CVpump is 4.2 percent. Additional

details regarding CVpump, along with the Secretaries'

responses to comments, are presented in Appendix B.

Intersampler variability, represented by CVsampler,

accounts for uncertainty due to physical differences from sampler to

sampler. Most of the commenters ignored this source of uncertainty. As

explained in Appendix B, the Secretaries have adopted a 5-percent

estimate of CVsampler.

To address commenters' concerns that the Agencies had

underestimated CVtotal, MSHA conducted a field study to

directly estimate the overall measurement precision attainable when

dust samples are collected with currently approved sampler units and

analyzed using state-of-the-art analytical techniques. The study

involved simultaneous field measurements of the same coal mine dust

cloud using sampling pumps incorporating constant flow technology.

Using a specially designed portable dust chamber, 22 tests were

conducted at various locations in an underground coal mine. Each test

consisted of collecting 16 dust samples simultaneously and at the same

location. No adjustments in the flow rate were made beyond what would

routinely have been done by an MSHA inspector.

Prior to the field study, two modifications to MSHA's sampling and

analytical method had been considered by MSHA and NIOSH: (1) Measuring

both the pre-and post-exposure weights to the nearest microgram

(g) on a balance calibrated using the established procedure

within MSHA's Respirable Dust Processing Laboratory; and (2)

discontinuing the practice of truncating the recorded weights used in

calculating the dust concentration. These modifications were

incorporated into the design of the field study.

One commenter characterized the field study as being ``woefully

incomplete'' because it was conducted ``in a tightly controlled

environment * * * not subject to normal environmental variation.''

While it is true that the samples within each test were not subject to

normal environmental variability, this was because the experiment was

deliberately designed to avoid confusing spatial variability in dust

concentration with measurement error. However, pumps were handled and

flow rates were checked in the same manner as during routine sampling.

Furthermore, the sampler units were disassembled and reassembled in the

normal manner to remove and replace dust cassettes.

Commenters also questioned the value that MSHA used in the February

1994 notice to represent uncertainty due to potential weighing errors.

In September 1994, MSHA submitted into the record an analysis based on

replicated weighings for 300 unexposed filter capsules, each of which

was weighed once by the cassette manufacturer and twice in MSHA's

laboratory [12]. An estimate of weighing imprecision derived from this

analysis was used by NIOSH in its September 20, 1995 assessment of

MSHA's sampling and analytical procedure (discussed in more detail

later).

In the March 12, 1996 joint notice, MSHA described the results of

an investigation into repeated weighings of the same capsules made over

a 218-day period using MSHA's automatic weighing system. It was noted

that after approximately 30 days, filter capsules left exposed and

unprotected gained a small amount of weight--an average of 0.8

g (micrograms) per day. Neither NIOSH nor MSHA considered this

a problem, since all dust samples are analyzed within 24 hours of

receipt and are not left exposed and unprotected. However, more recent

data collected to quantify weighing variability between the MSA and

MSHA laboratories showed that filter capsules tend to gain a small

amount of weight even when stored in plastic cassettes [13]. To check

this result, 75 unexposed filter cassettes that had been distributed to

MSHA's district offices were recalled and the filter capsules were

reweighed. On average, the weight gain was about 40 g over a

time period of roughly 150 days. Statistical analyses of these data

performed by MSHA and NIOSH confirmed the previous result [13,14].

While the cause has not been established, it is hypothesized that at

least some of the observed weight gain may be the result of outgassing

from the plastic cassette onto the filter capsule. If uncorrected, any

systematic change in weight not due to coal mine dust would introduce a

bias in dust concentration measurements.

One commenter had previously stated that the Secretaries were

addressing only precision, thereby implying that potential biases were

being ignored. To eliminate the potential for any bias due to a

spurious gain or loss of filter capsule weight, MSHA will use control

filter capsules in its enforcement program. Any change in weight

observed for the control filter capsule will be subtracted from the

measured change in weight of the exposed filter capsule. Each control

filter capsule will be pre-weighed with the other filter capsules, will

be stored and transported with the other capsules, and will be on the

inspector's person during the day of sampling. This modification to

MSHA's inspector sampling and analytical procedure will assure an

unbiased estimate of the true weight gain [14].

2. Verification of Method Accuracy

With its field study, MSHA exceeded the usual requirements for

determining the accuracy of a sampling and analytical method, as

described by NIOSH [1] and the European Community [2]. Both of these

require only a laboratory determination of method accuracy. NIOSH's

independent analysis of the study data determined, with 95-percent

confidence, that the

[[Page 5678]]

true CVtotal for MSHA's sampling and analytical method is

less than the target maximum value of 12.8 percent for concentrations

ranging from 0.2 mg/m3 to greater than 2 mg/m3

[3]. In other words, NIOSH demonstrated that, with two recommended

modifications, MSHA's sampling and analytical method for collecting and

processing single, full-shift samples would meet the NIOSH Accuracy

Criterion at dust concentrations greater than or equal to 0.2 mg/

m3.

NIOSH also applied an indirect approach for assessing the accuracy

of MSHA's sampling and analytical method. The indirect approach

involved combining independently derived estimates, previously placed

into the public record, of intra-laboratory weighing imprecision, pump-

related variability, and variability associated with physical

differences between individual sampler units. This indirect approach

also indicated that MSHA's sampling and analytical method meets the

NIOSH Accuracy Criterion at concentrations greater than or equal to 0.2

mg/m3, thereby corroborating the analysis of MSHA's field

data.

These NIOSH analyses predate MSHA's more recent data indicating a

correctable weight gain bias (discussed above). As explained in

Appendices A and B, the use of control filter capsules will eliminate

this bias but also affect the precision of a single, full-shift

measurement. Consequently, NIOSH reassessed the accuracy of MSHA's

sampling and analytical method, taking into account the effect of using

a control filter capsule on the measurement process [14]. After

accounting for the effects of control filter capsules on both bias and

precision, NIOSH concluded, based on both its direct and indirect

approaches, that a single, full-shift measurement will meet the NIOSH

Accuracy Criterion at dust concentrations greater than or equal to 0.3

mg/m3.

One commenter claimed that the Secretaries ``have not addressed the

`accuracy' of a single sample collected from an environment where the

concentration is unknown''. The purpose of any measurement process is

to produce an estimate of an unknown quantity. Since the Secretaries

have concluded that MSHA's sampling and analytical method for

inspectors meets the NIOSH Accuracy Criterion for true concentrations

ranging from 0.3 mg/m3 to greater than 2 mg/m3,

it is possible to calculate the range of measurements for which the

Accuracy Criterion applies. Since CVtotal increases at the

lower concentrations, it is important to determine the lowest

measurement at which the NIOSH Accuracy Criterion is met. If the true

concentration exactly equaled the lowest concentration at which MSHA's

sampling and analytical method meets the Accuracy Criterion (i.e., 0.3

mg/m3), no more than 5% of single, full-shift measurements

would be expected to exceed 0.36 mg/m3 [14]. Conversely, if

a measurement equals or exceeds 0.36 mg/m3, it can be

inferred, with at least 95% confidence, that the true dust

concentration equals or exceeds 0.3 mg/m3 [14].

Consequently, the Secretaries conclude that MSHA's improved sampling

and analytical method satisfies the NIOSH Accuracy Criterion whenever a

single, full-shift measurement is at or above 0.36 mg/m3.

As a result of the prior analyses, MSHA's existing inspector sample

processing procedures were changed to reflect the modifications that

were incorporated into MSHA's field study. MSHA is now pre- and post-

weighing inspector samples in the same laboratory, and reporting the

pre- and post-exposure weights of inspector samples to the nearest

microgram (g). As a result of NIOSH's latest analysis, MSHA

will now require its inspectors to use control filter capsules during

sampling. In addition, MSHA is now using only constant-flow control

pumps in the inspector sampling program. MSHA believes that exclusive

use of constant-flow pumps, as in the field study, further enhances the

quality of the Agency's sampling program.

The Secretaries recognize that future technological improvements in

MSHA's sampling and analytical method may reduce CVtotal

below its current value. Also, as additional data are accumulated,

updated estimates of CVtotal may become available. However,

so long as the method remains unbiased and CVtotal remains

below 12.8 percent, at a 95-percent confidence level, the sampling and

analytical method will continue to meet the NIOSH Accuracy Criterion,

and the present finding will continue to be valid.

VIII. Finding

The Secretaries have concluded that sufficient data exist for

determining the uncertainty associated with a single, full-shift

measurement; rigorous requirements are in place, as specified by 30 CFR

parts 70, 71, and 90, to ensure the validity of a respirable coal mine

dust sample; and valid statistical techniques were used to determine

that MSHA's improved dust sampling and analytical method meets the

NIOSH Accuracy Criterion. For these reasons the Secretaries find that a

single, full-shift measurement at or above 0.36 mg/m3 will

accurately represent atmospheric conditions to which a miner is exposed

during such shift. Therefore, pursuant to section 202(f) and in

accordance with section 101 of the Mine Act, the 1972 joint notice of

finding is hereby rescinded.

Appendix A--Why Individual Measurements are Unbiased

The accuracy of a measurement depends on both precision and bias

[1,3]. Precision refers to consistency or repeatability of results, and

bias refers to an error that is equally present in every measurement.

Since the amount of dust present on a filter capsule is measured, for

MSHA inspector samples, by subtracting the pre-exposure weight from the

post-exposure weight observed in the same laboratory, any bias in the

weighing process attributable to the laboratory is mathematically

canceled out by subtraction. A control filter capsule will be pre- and

post-weighted along with the exposed filter capsules. The weight gain

of each exposed capsule will be adjusted by subtracting the weight gain

or loss of the control filter capsule. Consequently, any bias

introduced during storage and handling of the filter capsules is also

mathematically canceled out. Therefore, since respirable dust is

defined by section 202(e) of the Mine Act to be whatever is measured by

an approved sampler unit, the Secretaries have concluded that a single,

full-shift measurement made with an approved sampler unit provides an

unbiased representation of average dust concentration for the shift and

sampling location sampled. Some commenters, however, suggested that

MSHA's sampling and analytical method is subject to systematic errors

that would have the same effect on all measurements. These comments are

addressed in this appendix.

I. The Value of the MRE Conversion Factor

The current U.S. coal mine dust standard is based on studies of

British coal miners. In these studies, full-shift dust measurements

were made using a sampler employing four horizontal plates which

removed the large-sized particles by gravitational settlement

(simulating the action of the nose and throat) and collecting on a pre-

weighed filter those particles which are normally deposited in the

lungs [6]. This instrument, known as the Mining Research Establishment

(MRE) sampler, was designed to collect airborne dust according to a

collection efficiency curve, developed by the British Medical Research

Council (BMRC) to approximate the deposition of inhaled

[[Page 5679]]

particles in the lung. Because the MRE instrument was large and

cumbersome, other samplers using a 10-mm nylon cyclone were developed

for taking samples of respirable dust in U.S. coal mines. However,

these cyclone-based samplers collected less dust than the MRE

instrument. Therefore, a factor was derived (1.38) to convert

measurements obtained with the cyclone-based samplers to measurements

obtained with the MRE instrument.

Two commenters noted that the 1.38 conversion factor was derived

from a comparison of MRE measurements to measurements obtained using

pumps made by two manufacturers [Mine Safety Appliances Co. (MSA) and

Unico]. These commenters noted that there was some variability in these

comparisons that MSHA and NIOSH did not consider in estimating

CVtotal, and noted that MSHA and NIOSH should therefore make

allowances for any error or uncertainty in the conversion factor. It

was also noted that the report deriving the conversion factor showed

that MSA pumps more closely approximated MRE concentrations than Unico

pumps, indicating that the 1.38 conversion factor (derived empirically

using both types of pumps) may systematically overestimate the MRE-

equivalent dust concentration for MSA samplers specifically. This

commenter argued that such potential bias in the conversion factor

should be addressed in order to account for the possibility of a

systematic error in the conversion.

The study referred by these commenters involved collecting side-by-

side samples using MRE and cyclone-based samplers [9]. The data showed

that multiplying the cyclone sample concentrations by a constant factor

of 1.38 gave values in reasonable agreement with MRE measurements.

Consequently, a conversion factor of 1.38 was adopted for use with

approved sampler units equipped with the 10-mm nylon cyclone.

Variability in the operating characteristics of individual sampler

units is expressed by CVsampler. In response to the comment

on potential bias, MSHA and NIOSH reviewed the original report

recommending the 1.38 MRE conversion factor. This report contained both

an empirical determination, using side-by-side comparison data

collected in underground coal mines, and a theoretical determination of

the conversion factor. Two sets of field data were collected: one set

was collected by mine inspectors who visited 200 coal mines across the

U.S.; the other set was collected by investigators from MSHA's

Pittsburgh laboratory at 24 coal mines. Linear regression was used to

analyze both sets of data, with the slope of the regression line

representing the conversion factor. The theoretical determination

suggested that the conversion factor should be close to a value of

1.35. Analysis of the district mine inspector data resulted in a

conversion factor of 1.38, while analysis of the laboratory

investigator data suggested a greater conversion factor of 1.45.

Because the conversion factor derived from the inspector data came

closer to the theoretical value, the former U.S. Bureau of Mines'

Pittsburgh Technical Support Center (in the Department of Interior)

recommended that 1.38 be the value adopted for any approved sampler

unit operating at 2.0 L/min and equipped with a 10-mm nylon cyclone.

This recommendation was subsequently accepted. The 1.38 conversion

factor was not, as implied by the commenters, meant to represent the

average value to be used with two different types of sampler unit, one

of which is no longer in use. Instead, based largely on the theoretical

value, it was meant to represent the appropriate value to be used with

any approved sampler unit operating at 2.0 L/min and equipped with a

10-mm nylon cyclone. No data or analyses were submitted to suggest that

this conversion factor, which has been accepted and used for over

twenty years, should be any other value.

II. Conforming to the ACGIH and ISO Standard

One commenter implied that the respirable dust cyclone

specifications used by MSHA result in a different particle collection

efficiency curve than that specified by the American Conference of

Governmental Industrial Hygienists (ACGIH) and the International

Organization for Standardization (ISO) for a respirable dust sampler.

Other commenters questioned whether the 2.0 L/min flow rate used by

MSHA was appropriate, since a NIOSH study recommended using a 1.7 L/min

flow rate when conforming to the recently adopted ACGIH/ISO

specifications for collecting respirable particulate mass.

It is true that MSHA's respirable dust cyclone specifications

result in a different particle size distribution than that specified by

ACGIH and ISO. However, this fact has no bearing on the conversion to a

respirable dust concentration as measured by an MRE sampler, which is

the basis of the respirable dust standard. The 1.38 factor used to

obtain an MRE-equivalent concentration was derived for a cyclone flow

rate of 2.0 L/min. If a flow rate of 1.7 L/min were used, then this

would correspond to some other factor for converting to an MRE-

equivalent dust concentration. Therefore, the particle size

distribution obtained at 2.0 L/min governs the relationship derived

between an approved respirable coal mine dust sampler and an MRE

sampler. The appropriate dust fraction (i.e., the fraction

corresponding to the 1.38 conversion factor) is sampled so long as the

specified 2.0 L/min flow rate is maintained.

III. Effects of Other Variables

The effects of any other variables on the sampled dust fraction are

covered by the 1.38 conversion factor, so long as these effects were

present in the data from which the conversion factor was obtained. For

example, one commenter expressed concern that nylon cyclones are

subject to performance variations due to static charging phenomena. Any

systematic effect of static charging on the performance characteristics

of the nylon cyclone is implicitly accounted for in the conversion

factor, because the same static charging effect would have been present

when the comparative measurements were obtained for deriving the

relationship between an approved sampler unit and an MRE instrument.

Random effects of static charging, i.e., effects that vary from sample

to sample, are included in CVtotal.

Appendix B--Components of CVtotal

I. Weighing Uncertainty

(a) Derivation of CVweight

The weight of a dust sample is determined by weighing each filter

capsule before and after exposure and then determining the weight gain

by subtraction. This weight gain is adjusted by subtracting any change

in weight observed for the unexposed, control filter capsule. This

practice eliminates potential biases due to any possible outgassing of

the plastic cassette or other time-related factors but introduces two

additional weighings. The weighing process is designed to control

potential effects of temperature, humidity, and contamination. However,

because the initial and final weighings of both the exposed and the

control filter capsules are each still subject to random error, there

is some degree of uncertainty in the computed weight of dust collected

on the filter.

For both the control and the exposed filter capsule, the error in

the weight-gain measurement results from combining two independent

weighing errors. For example, suppose that the true pre- and post-

exposure weights of

[[Page 5680]]

a filter capsule are W1=392.275 mg and W2=392.684

mg, respectively. The true weight gain (G) would then be:

G=W2-W1=0.409 mg.

If, due to weighing errors, pre- and post-exposure weights were

measured at w1=392.282 mg and w2=392.679 mg,

respectively, then the measured weight gain (g) would be:

g=w2-w1=0.397 mg.

The error (e) in this particular weight-gain measurement, resulting

from the combination of a 7 g error in w1 and a -5

g error in w2, would then be:

e=g-G=(w2-w1)-(W2-W1)=(w2

-W2) -(w1-W1)=-5-7=-12

g.4

\4\ Prior to mid-1995 there were two additional sources of

uncertainty in the weight gain recorded for MSHA inspector samples.

First, filter capsules were routinely weighed in different

laboratories before and after exposure, subjecting them to

interlaboratory variability. Second, the pre- and post-exposure

weights were both truncated down to the nearest exact multiple of

0.1 mg, below the weight actually measured, prior to recording

weight gain and calculating dust concentration.

---------------------------------------------------------------------------

Imprecision in the true weight gain is expressed by

e, the standard deviation of e. When a weight-gain

measurement (g) is converted to an MRE-equivalent concentration (in

units of mg/m3) based on a 480-minute sample at 2.0 L/min,

both the actual weight gain (G) and the weight-gain error (e) are

multiplied by the same factor:

[GRAPHIC] [TIFF OMITTED] TN31DE97.002

Therefore, the standard deviation of the propagated weighing error

component in a single, full-shift measurement (x=g1.438/m \3\ ) is

1.438e mg/m \3\, assuming no adjustment for weight

change in the control filter capsule.

Since a control filter capsule will be used to eliminate potential

bias, the weight gain measured for the exposed filter (g) will be

adjusted by subtracting the change in weight (which may be positive or

negative) observed for the control filter capsule (g'). Therefore, the

adjusted measurement of dust concentration is

[GRAPHIC] [TIFF OMITTED] TN31DE97.003

Any change in weight observed for the control filter capsule is

subject to the same measurement imprecision due to random weighing

errors, represented by e, as the weight gain

measurement for an exposed filter. In addition to the weight-gain error

for the exposed filter whose measured weight gain is g, x' will also

contain a weight-gain error contributed by the measured change in

weight of the control filter capsule (g'). Using a standard

propagation-of-errors formula, the imprecision in g-g' is represented

by

[GRAPHIC] [TIFF OMITTED] TN31DE97.004

Therefore, the standard deviation of the propagated weighing error

component in the adjusted measurement is

1.438e2 mg/m \3\.

To form an estimate of CVweight when control filter

capsules are used, the estimated value of 1.438e is

multiplied by 2 and expressed as a percentage of the true dust

concentration being measured (X):

[GRAPHIC] [TIFF OMITTED] TN31DE97.005

Since e is essentially constant with respect to

dust concentration, CVweight decreases as the dust

concentration increases.

(b) Values Expressing Weight-Gain Uncertainty

Table 1 summarizes six different values of

e that have been mentioned during the proceedings

related to this notice and two additional values for

e derived in this appendix from data introduced

during these proceedings. A ninth value for e is

derived from newly acquired data being placed into the record along

with this notice [14]. The nine values listed in Table 1 are not

inconsistent, but as explained below, represent estimates of weight-

gain imprecision during different historical periods or under different

sample processing procedures.

Table 1.--Standard Deviation of Error in Weight Gain

----------------------------------------------------------------------------------------------------------------

e

Description Reference (g)

----------------------------------------------------------------------------------------------------------------

MSHA's historical estimate of upper bound............ 59 FR 8356, [15].......................... 97.4

1981 Measurement Assurance Estimate (older [16,17]................................... 81

technology, truncation of weights).

Experiment on 300 unexposed, tamper-resistant filter [12]...................................... 29

capsules (pre- and post-weighing in different labs;

no truncation).

Inspector samples processed between late 1992 and mid Appendix B................................ 51.7

1995 (truncation of weights; pre- and post-exposure

weighing in different labs; adjusted for differences

between labs).

NMA Data (obtained from samples collected by Skyline Appendix C................................ 76

Coal, Inc.).

Value used in NIOSH ``indirect approach'' (pre- and 61 FR 10012, [12]......................... 5.8

post-exposure weighing on same day and in the same

lab; derived from Kogut [12]).

MSHA Field Study..................................... [18,3].................................... 9.1

1996 Measurement Assurance Estimate.................. 61 FR 10012, [19]......................... 6.5

1997 field data (75 unexposed capsules).............. [14]...................................... 8.2

----------------------------------------------------------------------------------------------------------------

In MSHA's February 1994 notice, 1.438e

(identified as ``variability associated with the pre- and post-weighing

of the filter capsule'') was presented as 0.14 mg/m3, or 7

percent of 2.0 mg/m3, as described in Kogut [15]. It follows

that the value of e implicitly assumed in MSHA's

February 1994 notice (obtained by dividing 0.14 by 1.438) was 0.0974 mg

(97.4 g). Seven percent of 2.0 mg/m3 had been used

by MSHA from the inception of its dust enforcement program to represent

an upper bound on weighing imprecision in a dust concentration

measurement.

After publication of the February 1994 notice, several other

candidate values for e were placed into the public

record. In 1981, based on data collected to implement a measurement

assurance program in MSHA's weighing laboratory, e

was estimated using a method developed by the NBS to be 0.0807 mg (80.7

g) [16]. The published NBS estimate reflected weighing

technology in place at the time the article was published (1981), as

well as the practice (no longer in effect for MSHA inspector samples)

of truncating both the pre- and post-exposure weights down to an exact

multiple of 0.1 mg. This estimate was used to calculate

CVweight by Bartley [17], in September 1994.

Some commenters misread or misunderstood the published NBS

estimate. One of these commenters claimed that ``the only published

report of the weighing error in MSHA's

[[Page 5681]]

laboratory * * * was 0.16 mg of variation, which would convert to a

concentration of 0.20 mg/m3 compared to the 0.14 mg/

m3 * * * MSHA and NIOSH used.'' This is incorrect, since the

standard deviation of weight-gain errors (including the effect of

truncation) is actually identified as 0.0807 mg in the Appendix to

Parobeck et al. [16]. The 0.16-mg figure quoted by the commenter is

presented in that paper as defining a 2-tailed 95-percent confidence

limit, for use in establishing process control limits. It is derived by

multiplying e by 2.0. As explained above, the

published value of e = 0.0807 mg is multiplied by

1.438 to propagate an MRE-equivalent concentration error of 0.116 mg/

m3. Contrary to the commenters' assertion, this is less--not

more--than the quantity (0.14 mg/m3) assumed in the February

1994 notice.

In September 1994, a more recent analysis was placed into the

public record, based on repeated weighings of 300 unexposed filter

capsules, each of which was weighed once in the MSA laboratory and

twice in MSHA's laboratory using current equipment [12]. Based on this

analysis, e was estimated to be 29 g for

pre- and post-weighings on different days at different laboratories, or

5.8 g for pre- and post-weighings on the same day within

MSHA's laboratory. The 5.8-g value was used as part of the

NIOSH ``indirect approach'' in its 1995 accuracy assessment [3].

Neither of these two estimates, however, reflects the effects of

truncation or of a mean difference of about 12 g discovered

between weighings in the two laboratories. Combining these two

additional effects with the 29-g estimate results in an

adjusted estimate of e = 51.7 g for

weighings made in different laboratories and truncated to a multiple of

0.1 mg. MSHA and NIOSH regard this 51.7-g value to be the best

available estimate of e for inspector samples

processed between late 1992, when the current style of (tamper-

resistant) cassette was introduced, and mid-1995, when the most recent

changes in inspector sample processing were implemented.

Some commenters suggested that the estimates of

e, placed into the record in September 1994, did

not adequately account for potential errors in the weighing process as

it existed at that time. One of these commenters asserted that

truncation error was an additional source of uncertainty that had not

been accounted for. As explained above, however, e

accounts for uncertainty deriving from both the pre- and post-exposure

weighings. Both the 80.7-g NBS estimate and the 97.4-

g value assumed in the February 1994 notice included the

effects of truncating weight measurements to 0.1 mg. Truncation effects

are also included in the 51.7-g estimate.

Some commenters expressed special concern over the accuracy of pre-

exposure filter capsule weights as measured by MSA. One commenter

expressed ``grave concern'' with regard to the 12-g systematic

difference in weights found between MSA and MSHA weighings of the same

unexposed capsules, as described in MSHA's 1994 analysis [12]. These

concerns are moot, at least with respect to MSHA's inspector sampling

program, since all inspector samples are now pre- and post-weighed at

MSHA's laboratory. Furthermore, any potential bias resulting from

differences in laboratory conditions on the days of pre- and post-

exposure weighings should be eliminated by the use of control filter

capsules. However, contrary to this commenter's interpretation, the

analysis submitted to the record in September 1994 resulted in a

substantially lower estimate of e than that assumed

in the February 1994 notice--even after adjustment for the 12-

g systematic difference observed between weighing

laboratories. The 51.7-g estimate discussed above includes

this adjustment.

MSHA and NIOSH also analyzed data submitted by the NMA in

connection with these proceedings. An important result of that

analysis, described in Appendix C, was an estimate of

e equal to 76 g 15

g.5 This estimate is not significantly different,

statistically, from either the 97.4-g value assumed in the

February 1994 notice, the 80.7-g NBS estimate, or the 51.7-

g value estimated for samples collected between late 1992 and

mid-1995. Since the NMA data were obtained from samples collected by

Skyline Coal, Inc., prior to 1995, the Secretaries believe these data

confirm the 51.7-g value of e applicable

to the Skyline samples. The estimate of e obtained

from the Skyline data is, however, significantly greater than the value

estimated for weight-gain measurements under MSHA's current inspection

program. This is explained by the fact that when the Skyline samples

were collected, all samples were weighed in different laboratories

before and after sampling, and the weights were truncated to 0.1 mg.

before calculating the weight gain.

---------------------------------------------------------------------------

\5\ To construct a 90-percent confidence interval for

G, based on the Skyline data, the 15-

g ``standard error of the estimate'' must be

multiplied by a confidence coefficient of 1.64.

---------------------------------------------------------------------------

Truncation of weights, and also the practice of pre- and post-

weighing samples in different laboratories, were discontinued for

inspector samples in mid-1995. Under MSHA's revised procedures for

processing inspector samples, filter capsules are weighed both before

and after sampling in MSHA's laboratory. Furthermore, the results

recorded and used in calculating dust concentrations are expressed to

the nearest g. Therefore, the 5.8-g estimate of

e described above, applying to pre- and post-

exposure weighings in the same laboratory using current equipment and

no truncation, was used by NIOSH to calculate CVweight as

part of the NIOSH ``indirect'' evaluation of CVtotal, placed

into the public record on March 12, 1996.

Based on the results of MSHA's 1995 field study,

e was estimated to be 9.12 g [18]. In this

study, the filter capsules were used to collect respirable coal mine

dust samples in an underground mine between pre- and post-exposure

weighings in MSHA's laboratory, potentially subjecting them to unknown

sources of variability in weight gain not covered by the laboratory

estimates. Substituting the estimated value of e =

9.12 g into Equation 3 results in a corresponding estimate of

CVweight that declines as the sampled dust concentration

increases--ranging from 9.3 percent at dust concentrations of 0.2 mg/

m3 to less than one percent at concentrations greater than

2.0 mg/m3. This estimate of CVweight applies to

the procedure utilizing control filter capsules.

An updated estimate of e = 6.5 g was

also calculated using the published NBS procedure for filter capsules

processed with the current equipment and procedures for inspector

samples. This estimate, derived from weighing the same group of 55

unexposed filter capsules 139 times over a 218-day period, was

described in material placed into the public record on March 12, 1996

[19]. The 6.5 g estimate applies to filter capsules pre- and

post-weighed robotically on different days within MSHA's laboratory,

but it does not reflect any potential effects of removing the capsule

from the laboratory and exposing it in the field between weighings.

The estimate of imprecision in measured weight gain derived from

the MSHA's 1995 field study discussed earlier (9.1 g), falls

only slightly above the 6.5 g laboratory estimate. This

suggests that the process of handling and actually exposing the filter

capsule in a mine environment does not add appreciably to the

imprecision in measured weight gain.

[[Page 5682]]

In February 1997, 75 unexposed filter capsules that had been pre-

weighed in MSHA's laboratory and distributed to MSHA district offices

were recalled and reweighed [13]. After adjusting for variability

attributable to the date of initial weighing (i.e., variability that

would be eliminated by use of a control filter capsule), these data

provide an estimate of e equal to 8.2 g

[14]. This estimate, which is based on weighings separated by a span of

about four to five months, corroborates the 9.1 g estimate

obtained from MSHA's 1995 field study.

(c) Negative Weight-Gain Measurements

Some commenters pointed out that MSHA routinely voids samples when

the measured pre-exposure weight of a filter capsule is greater than

the measured post-exposure weight. According to these commenters, such

occurrences reflect an unacceptable degree of inaccuracy in weight-gain

measurements. One commenter asserted that such cases are ``of

particular significance when only one sample is relied upon.'' This

commenter attributed such occurrences solely to errors in the capsule

pre-weight and implied that they should not be expected to occur under

MSHA's quality assurance program. It was, therefore, implied that

negative weight-gain measurements are not consistent with the degree of

uncertainty being attributed to weighing error.

Prior to implementation of the 1995 processing modifications, a

significant fraction of samples with less than 0.1 mg of true weight

gain (i.e., G -0.1 mg). Contrary to the commenter's

implication, however, negative weight-gain measurements do not arise

exclusively from positive pre-exposure weighing errors (i.e.,

w1 > W1). They can also arise, with equal

likelihood, from negative post-exposure weighing errors (i.e.,

w2 2).

What is required for a negative weight gain (w2 1) is that e e fully accounts

for the probability of such occurrences. Naturally, this probability

becomes smaller as G increases and also as e

decreases.

The occasional negative weight-gain measurements that have been

observed are consistent with values of e estimated

for previous processing procedures. Table 2 contains the probability of

a negative weight-gain measurement for true weight gains (G) ranging

from 0.0 mg to 0.08 mg, assuming e = 51.7

g and the previous practice of truncation, which has now been

discontinued for inspector samples. Since the purpose here is to

evaluate the probability of negative weight gains under MSHA's previous

processing procedures, it is also assumed that no control filter

capsules are used to adjust weight gains.

Table 2.--Probability of Negative Weight-Gain Measurement, Assuming

Truncation and e=51.7 g

------------------------------------------------------------------------

Estimated probability of negative

True weight gain G=W2-W1 (mg) measurement, %

------------------------------------------------------------------------

0.00............................... 12.9

.01................................ 8.4

.02................................ 5.1

.03................................ 2.8

.04................................ 1.5

.05................................ 0.7

.06................................ .4

.07................................ .2

.08................................ .1

------------------------------------------------------------------------

Note: Tabled probabilities (in percent) were obtained from a simulation

of 35,000 weight-gain measurements at each value of G, assuming

normally distributed weighing errors and the now discontinued practice

of measurement truncation.

One commenter suggested the use of a test based on the frequency of

negative weight-gain measurements to check the magnitude of the MSHA/

NIOSH estimate of CVtotal. As proposed by the commenter, the

test of CVtotal would consist of comparing the observed

proportion of samples voided due to a negative recorded weight gain to

the proportion expected, given CVtotal equal to the MSHA/

NIOSH estimate. If the observed proportion were to exceed the expected

proportion, then this would constitute evidence that CVtotal

was being underestimated.

The commenter miscalculated the expected proportion, because he

mischaracterized the MSHA/NIOSH estimate of CVtotal as

constant over the continuum of dust concentrations. The MSHA/NIOSH

estimate of CVtotal increases as dust concentrations

decrease. This would cause a higher proportion of negative results than

what the commenter projected under the MSHA/NIOSH estimate, regardless

of what statistical distribution of dust concentrations is assumed.

The commenter's projection also neglected to take into account the

effects of truncating pre- and post-exposure weights to multiples of

0.1 mg. Although this practice has now been discontinued for MSHA

inspector samples, it is a factor in the available historical data.

In principle, if the statistical distribution of true dust

concentrations were known, the expected proportion of samples voided

for negative weight gain could be recalculated to reflect both a

variable CVtotal and, when applicable, truncation of

recorded weights. However, under the commenter's proposal, deriving the

expected proportion of negative measurements would involve not only

CVtotal, but also an estimate of the distribution of true

dust concentrations. Such an estimate would rely on the tenuous

assumption that a mixture of dust concentrations in different

environments is closely approximated by a lognormal distribution far

into the lower tail--i.e., even at concentrations extremely near zero.

Furthermore, valid estimation of the lognormal parameters, applicable

to dust concentrations near zero, would be complicated by measurement

errors, especially those resulting in negative or zero values.

Depending on the data used, truncation effects could also confound the

analysis.

Before truncation was discontinued, negative weight-gain

measurements were caused by various combinations of pre- and post-

exposure weighing and truncation error. Since truncation, and

especially interlaboratory variability, have now been removed as

sources of error in weight-gain measurements for inspector samples,

negative weight-gain measurements are expected to occur less frequently

than in the past.

(d) Comparing weight gains obtained from paired samples

Some commenters maintained that ``although there may be slight

differences between how the samples are dried * * *,'' differences

between the weight gain observed in MSHA samples and simultaneous

samples collected nearby (and processed at an independent laboratory)

indicated a greater degree of weighing uncertainty than what was being

assumed. In response to the Secretaries' request for any available data

supporting this position, results from paired dust samples were

provided by two coal companies.

In comparing measurements obtained from paired samples, there are

several important considerations that some commenters did not take into

account. First, if two different sampler units are exposed to identical

atmospheres for the same period of time, the difference between weight-

gain measurements g1 and g2 arises, in part, from

two independent weight-gain measurement errors, e1 and

e2. If uncertainty due to

[[Page 5683]]

each of these errors is represented by se, then the

difference between g1 and g2 has uncertainty due

to weighing error equal to se2. Consequently,

weight gains measured in the same laboratory, on the same day, for

different filter capsules exposed to identical atmospheres can be

expected to differ by an amount whose standard deviation is

1.41se.

Furthermore, if the two exposed capsules are processed at different

laboratories, the difference in weight gains contains an additional

error term arising from differences between laboratories. Evidence was

presented that this term ( in the notation of [12])

is far more significant than the intra-lab, intra-day weighing error in

MSHA's laboratory. Moreover, the additional uncertainty introduced by

use of a third laboratory also depends on unknown weighing imprecision

within that laboratory, which may differ from that maintained by MSHA's

measurement assurance process. (See Appendix C for analysis of paired

sample data submitted by NMA).

However, the most important consideration in comparing weight gains

from two different samples is that under real mining conditions, the

atmospheres sampled may not be identical--even if the sampler units are

located near one another. Differences in atmospheric dust

concentrations over relatively small distances have been documented

[20]. Such differences would be expected to produce corresponding

differences in weight gain that are unrelated to the accuracy of a

single, full-shift measurement as defined by the measurement objective

explained earlier in this notice.

II. Pump Variability

The component of uncertainty due to variability in the pump,

represented by CVpump, consists of potential errors

associated with calibration of the pump rotameter, variation in flow

rate during sampling, and (for those pumps with rotameters) variability

in the initial adjustment of flow rate when sampling is begun. The

Secretaries believe that CVpump adequately accounts for all

uncertainty identified by commenters as being associated with the

volume of air sampled.

In deriving the Values Table published in MSHA's February 1994

notice, MSHA used a value of 5 percent to represent uncertainty

associated with initial adjustment of flow rate at the beginning of the

shift and another value of 5 percent to represent flow rate

variability. The 5-percent value for variability in initial flow rate

adjustment was estimated from a laboratory experiment conducted by MSHA

in the early 1970s, while the value for flow rate variability was based

on the allowable flow rate tolerance specified in 30 CFR part 74. This

part requires that the flow rate of all sampling systems not vary by

more than 5 percent over a full shift with no more than two

adjustments. MSHA did not include a separate component of variability

for pump rotameter calibration because it was already included in the

5-percent value used to represent flow rate variability.

Based on a review of published results [10], the Secretaries

concluded that the component of uncertainty associated with the

combined effects of variability in flow rate during sampling and

potential errors in calibration is less than 3 percent. Therefore, as

proposed in the March 12, 1996 notice, the Secretaries are now

estimating uncertainty due to variability in flow rate to be 3 percent.

Because MSHA could not provide the experimental data supporting the

5-percent value used to represent uncertainty associated with the

initial adjustment of flow rate, one commenter recommended that MSHA

conduct a new experiment. In response to that request, MSHA conducted a

study to establish the variability associated with the initial flow

rate adjustment. The study, placed into the public record on September

9, 1994, attempted to emulate realistic operating conditions by

including a variety of sampling personnel making adjustments under

various conditions. Results showed the coefficient of variation

associated with the initial adjustment to be 3 0.5 percent

[11]. The Secretaries consider this study to provide the best available

estimate for uncertainty associated with the initial adjustment of a

sampler unit's flow rate. Therefore, as proposed in the March 12, 1996

notice, the Secretaries are now estimating uncertainty due to

variability in the initial adjustment to be 3 percent.

One commenter expressed concern regarding how representative MSHA's

study on initial flow rate adjustment was of actual sampling

conditions. The Secretaries consider the conditions under which the

study was conducted to have adequately mimicked conditions under which

the flow rate of a coal mine dust sampling system is adjusted. This was

more rigorous than the original study, from which MSHA estimated the 5-

percent value assumed in the February 12, 1994 notice. The tests were

conducted in an underground mine, using both experienced and

inexperienced persons to make the adjustments. Also, the only

illumination was supplied by cap lamps worn by the person making the

adjustments. Tests were conducted for adjustments made in three

different physical positions: standing, kneeling and prone. Inspection

personnel participating in the study provided guidance as to the

methods typically used by inspection personnel in adjusting pumps. In

fact, environmental conditions under which the test was conducted were

generally more severe than those normally encountered by inspection

personnel, since initial adjustment of the pumps normally occurs on the

surface just before the work shift begins.

The same commenter also questioned why only the variability

associated with initial adjustment of the flow rate was estimated and

not the variability associated with subsequent adjustments during the

shift. This is because the variability associated with the subsequent

flow rate adjustments of an approved sampler unit is already included

in the 3-percent value estimated for variability in flow rate over the

duration of the shift.

Since variability in the initial flow rate adjustment is

independent of calibration of the pump rotameter and variability in

flow rate during sampling, these two sources of uncertainty can be

combined through the standard propagation of errors formula:

[GRAPHIC] [TIFF OMITTED] TN31DE97.006

This estimate accords well with a more recent finding based on 186

measurements in an underground mine, using constant flow-control pumps

[18]. That study estimated CVpump = 4.0 percent and

concluded that CVpump was unlikely to exceed 4.4 percent.

Three commenters stated that there are reports of sampling pumps

being calibrated and used at altitudes differing by as much as 3000

feet and that, for many pumps, this could result in more than a 3-

percent change in flow rate per 1000 feet of altitude. MSHA recognized

this as a potential problem as early as 1975. As a result, MSHA

conducted a study to ascertain the effect of altitude on coal mine dust

sampler calibration [21]. The study showed that both pump performance

and rotameter calibration were affected by changes in altitude but that

an approved MSA sampling system, calibrated and adjusted at an altitude

of 800 feet to a flow rate of 2.0 L/min, would meet the requirement of

30 CFR 74.3(11) when sampling at an altitude of 10,000 feet, even if no

adjustment were made to the pump. The study also provided equations for

adjusting the calibration mark on the pump rotameter so that, when

sampling at an altitude

[[Page 5684]]

different from the one at which the rotameter was calibrated, the

appropriate flow rate would be obtained. These procedures are used by

MSHA inspectors in instances where the sampling altitude is

significantly different from the altitude where the sampling system is

calibrated.

Some commenters questioned the ability of the older MSA Model G

pumps to meet the same flow rate specifications as new pumps. MSHA has

discontinued the use of these older pumps in its sampling program and

will be using only flow-control pumps. More recent MSHA studies show

that these pumps continue to meet the flow rate requirement of 30 CFR

74.3(11) at altitudes up to 10,000 feet [22]. As a result, the flow-

control pumps currently used by inspectors can be calibrated at one

altitude and used at another altitude with no additional adjustments

made to the pumps. Furthermore, all sampler units used to measure

respirable dust concentrations in coal mine environments are required

to be approved in accordance with the regulatory requirements of 30 CFR

part 74, which require flow rate consistency to be within

0.1 L/min of the 2.0 L/min flow rate.6 MSHA's experience

over the past 20 years has demonstrated that flow rate consistency of

older sampling systems will continue to meet the requirements specified

in part 74, provided the systems are regularly calibrated and

maintained in approved condition. To ensure that sampling systems

continue to meet the specification of part 74, MSHA's policy requires

calibration and maintenance by specially trained personnel in

accordance with MSHA Informational Report No. 1121 (revised).

---------------------------------------------------------------------------

\6\ Section 74.3(13) requires that flow rate in an approved

sampler unit deviate from 2.0 L/min by no more than 5 percent over

an 8-hour period, with no more than 2 readjustments after the

initial setting. However, this is a maximum deviation, and the

uncertainty associated with pump flow rate, as quantified by its

coefficient of variation, is 3 percent.

---------------------------------------------------------------------------

III. Intersampler Variability

Intersampler variability, represented by CVsampler,

accounts for uncertainty due to physical variations from sampler to

sampler. Most of the commenters ignored this source of uncertainty. One

commenter, however, stated that 10-mm nylon cyclones are subject to

performance variations due to static charging phenomena (discussed in

Appendix A).

Intersampler variability was investigated by Bowman et al. [10],

Bartley et al. [17], and Kogut et al. [18]. Bowman et al. designed a

precision experiment to determine the contribution to

CVtotal from differences between individual coal mine dust

sampler units. Based on their experiment, they reported

CVsampler = 1.6 percent, which included variation in both

the 10-mm nylon cyclone and the MSA Model G pump. They concluded that

this low degree of component variability indicates there is excellent

uniformity in the mechanical components of dust sampler units. Bartley,

from his experimental investigation of eight 10-mm nylon cyclones,

estimated CVsampler to be no more than 5 percent for

aerosols with a size distribution typical of those found in coal mine

environments. Based on an analysis involving 32 different sampler

units, Kogut et al. found that CVsampler was unlikely to

exceed 3.1 percent. Unlike Bartley's study, however, this analysis

relied on new cyclones, which might be expected to exhibit less

variability than older, heavily used cyclones. Therefore, NIOSH used

the more conservative estimate of 5 percent, with an upper 95-percent

confidence limit of 9 percent, in its ``indirect approach'' for

estimating CVtotal and evaluating method accuracy [3].

Appendix C--Data Submitted by Commenters

During the public hearings, several commenters indicated they had

data showing that MSHA and NIOSH had underestimated the overall

magnitude of uncertainty associated with a single, full-shift

measurement. These data and accompanying analyses were submitted to the

record and evaluated by MSHA and NIOSH. Some of the data sets consisted

of paired samples, where two approved sampler units were placed nearby

one another and operated for a full shift. One of the resulting samples

was analyzed in MSHA's laboratory and the other by an independent

laboratory. These data were represented as showing that single, full-

shift measurements cannot accurately be used to estimate dust

concentrations. Other data sets submitted consisted of unpaired

measurements collected from miners at intervals over varying spans of

time. These data sets were represented as showing that exposures vary

widely between shifts and between occupations.

I. Paired Sample Data Submitted by the NMA

The American Mining Congress and National Coal Association [AMC and

NCA have since merged into the National Mining Association, (NMA)]

submitted at the request of MSHA and NIOSH a data set consisting of 381

pairs of exposure measurements. These measurements had been obtained

from the ``designated occupations'' on two longwall and six continuous

mining sections belonging to Skyline Coal, Inc. Two sampling units were

placed on each participating miner and operated for the full shift.

After sampling, one sample cassette was sent to MSHA for analysis while

the other was analyzed at a private laboratory. All samples were

reported to be ``portal to portal'' samples as required by MSHA

regulations. Using these data, the NMA estimated an overall CV of 16

percent. Based on this 16-percent estimate, the NMA suggested that MSHA

had underestimated measurement uncertainty in its February 1994 notice

by 60 percent at dust concentrations of 2.0 mg/m\3\.

The NMA estimate of 16 percent for overall CV includes not only

sampling and analytical error, but also variability arising from two

additional sources: (1) Spatial variability between the locations where

the two samples were collected; and (2) interlaboratory variability

introduced by the fact that a third laboratory was involved in weighing

exposed filter capsules.

Since the two dust samples within each pair submitted were not

collected at precisely the same location, differences observed between

paired samples in the Skyline data are partly due to spatial

variability. The Secretaries fully recognize and acknowledge that, as

suggested by the Skyline data, spatial variability in mine dust

concentrations can exist, even within a relatively small area such as

the so-called breathing zone of a miner. Consistent with general

industrial hygiene practice, however, the Secretaries do not consider

such variability relevant to the accuracy of an individual dust

concentration measurement.

The NMA expressed sampling and analytical error as a single

percentage relative to the average of all dust concentrations that

happened to be observed in the data analyzed. Contrary to the NMA

analysis, sampling and analytical error cannot be expressed as a

constant percentage of the true dust concentration. Because

e is constant with respect to dust concentration,

CVweight declines with increasing dust concentration, as

explained in Appendix B. The value of CVtotal assumed by

MSHA and NIOSH for the period when the Skyline samples were collected

is approximately 7.5 percent when the true dust concentration

() is 2.0 mg/m \3\ and approximately 16.2 percent when

= 0.5 mg/m \3\. This is based on applying Equations 2 and 3

to

[[Page 5685]]

e = 51.7 g, CVpump = 4.2

percent, and CVsampler = 5 percent.

Even if the effects of spatial variability and the third laboratory

are ignored, and the overall CV is interpreted as an average over the

range of concentrations encountered, the 16-percent value reported by

the NMA makes no allowance for the paired covariance structure of the

data. Therefore, MSHA and NIOSH consider the 16-percent value to be

erroneous, even under NMA's assumptions.

MSHA and NIOSH re-analyzed the Skyline data in order to check

whether these data were consistent with the value of

e (i.e., 51.7 g) estimated for the time

when the Skyline samples were collected. To distinguish the NMA

interpretation of sampling and analytical error (including spatial

variability) from the Secretaries' interpretation (excluding spatial

variability), SAE will denote sampling and analytical error according

to the Secretaries' interpretation, and SAE* will denote

sampling and analytical error according to the NMA interpretation. If

CVspatial denotes the component of SAE*

attributable to spatial variability for each measurement, it follows

that

SAE* = (CV \2\total +

CV\2\spatial)1/2.

To estimate SAE* as a function of dust concentration

from the data provided, a least-squares regression analysis was

performed on the square of the difference between natural logarithms of

dust concentrations x1 and x2 observed within

each pair. Let * denote the true mean dust

concentration, not only over the full shift sampled, but also over the

two locations sampled. The expected value (E{}) of each squared

difference forms the ordinate of the regression line at each value of

the abscissa (1/*)\2\:

E{(Ln(X1)-Ln(X2)) 2}

2(SAE*) 2

= 2(CV 2total+CV 2spatial)

= 2[CV 2pump+CV 2sampler+CV

2 weight+CV 2spatial]

= 2(CV2pump+CV 2sampler+CV

2spatial)+

2(1.438e/*)2

=a0+a1(1/*) 2

Since no control filter capsules were used in processing the

Skyline dust samples, CV weight does not, in this analysis,

contain the 2 factor shown in Equation 3 of Appendix B. The

intercept of the regression line is

a0=2(CV\2\pump+CV2+sampler+C

V 2 spatial), and the slope is

a1=2(1.438e) 2. To carry out

the regression analysis, * was approximated by

(x1+x2)/2. Regression estimates of the parameters

a0 and a1 were used to generate corresponding

estimates of e and CV 2

spatial.

The least squares estimate of e obtained from

this analysis is 76.0 g, with standard error of 15

g. This is not significantly different, statistically, from

the 51.7-g value estimated for the time period when the

Skyline samples were collected. Assuming CVpump=4.2 percent

and CVsampler=5 percent, the value of CV

This text is long and has been trimmed here. Open the source document for the complete record.

This is a copy of a public record, reproduced as it was published. It is not legal advice, and it may not be the version a court would rely on. Check the official source before you cite it.

A word about cookies

We need a few to keep you signed in and the library working. The rest help us see which pages people use and where they get stuck. They stay off unless you say yes.