Detroit Testing Laboratory, Inc., Application for Recognition

Federal RegisterNov 21, 1997

Ask Donna

What actually matters in this document.

Text

DEPARTMENT OF LABOR

Occupational Safety and Health Administration

[Docket No. NRTL-2-97]

Detroit Testing Laboratory, Inc., Application for Recognition

AGENCY: Occupational Safety and Health Administration; Labor.

ACTIONS: Notice of application for recognition as a Nationally

Recognized Testing Laboratory, and preliminary finding.

-----------------------------------------------------------------------

SUMMARY: This notice announces the application of Detroit Testing

Laboratory, Inc. for recognition as a NRTL under 29 CFR 1910.7, and

presents the Agency's preliminary finding.

DATES: The last date for interested parties to submit comments is

January 20, 1998.

ADDRESSES: Send comments concerning this notice to: NRTL Recognition

Program, Office of Variance Determination, Occupational Safety and

Health Administration, U.S. Department of Labor, 200 Constitution

Avenue, N.W., Room N3653, Washington, D.C. 20210.

FOR FURTHER INFORMATION CONTACT: Bernard Pasquet, Office of Variance

Determination, NRTL Recognition Program at the above address, or phone

(202) 219-7056.

SUPPLEMENTARY INFORMATION:

Notice of Application

Notice is hereby given that Detroit Testing Laboratory, Inc. (DTL)

has made application pursuant to 29 CFR 1910.7, for recognition as a

Nationally Recognized Testing Laboratory.

The address of the laboratory covered by this application is:

Detroit Testing Laboratory, Inc., 7111 E. Eleven Mile, Warren, Michigan

48092.

Background

Detroit Testing Laboratory, Inc. (DTL), according to the applicant,

is a Michigan corporation and was formally incorporated in 1949. The

applicant states that the lab was originally founded in 1903 as a

partnership, that ownership of the lab changed in 1948 and again in

1968, and that in 1976, the current owner purchased DTL as sole

stockholder.

The applicant submitted an application package, and separately

submitted a Quality Assurance (QA) Manual (see Exhibits 2A and 2B). The

QA Manual includes: an organization chart, position descriptions, and

resumes of key personnel; department descriptions including equipment &

standards used for departments involved in testing; description of

certifications done and standards used for certification; and the

details on how calibrations are handled, including descriptions of

equipment and standards.

Capability

Section 1910.7(b)(1) states that for each specified item of

equipment or material to be listed, labeled or accepted, the laboratory

must have the capability (including proper testing equipment and

facilities, trained staff, written testing procedures, and calibration

and quality control programs) to perform appropriate testing.

The applicant has one main facility at its site in Warren,

Michigan, and a smaller test facility in Center Line, Michigan. This

smaller site is not included in the applicant's request for

recognition. The applicant claims that natural gas, electric,

compressed air, steam, and water are available in the laboratory for

product testing and for calibrations and tests.

The applicant's QA Manual shows the testing experience of its key

testing staff, mentions its certification, and listing and labeling

experience with products, and describes its testing capabilities and

experience in a number of specific areas. It also contains a list of

major instrumentation and equipment.

Quality Assurance Procedures, Test/Operating procedures (developed

on a form, the original of which is kept by each lab), calibration

procedures, and audits (including proficiency audits which depends in

part on the use of outside private services) are described in the QA

manual. Furthermore, the QA includes an Internal Corrective Action

Procedure whereby reports are issued to an area when it operates

outside the guidelines of the QA System. The QA Manual also contains a

sample handling procedure and procedures on employee training. Written

procedures exist for typical tests, per QA manual.

Control Procedures

Section 1910.7(b)(2) requires that the NRTL provide certain

controls and services, to the extent necessary, for the particular

equipment or material to be listed, labeled, or accepted. These consist

of implementation of control procedures for identifying the listed or

labeled equipment or materials, inspecting the production runs at

factories to assure conformance with test standards, and conducting

field inspections to monitor and assure the proper use of identifying

marks or labels.

The application contains the description of the listing and

labeling procedure, which indicates ``inspections'' will be done four

times per year, and periodic compliance testing is done every four

years. A sample listing and follow-up agreement was also provided. In

addition, ``Instructions for * * * Inspections * * * ,'' and a sample

inspection form were submitted.

[[Page 62359]]

Independence

A statement of independence was supplied attesting that DTL is

independent of any producer, supplier, or vendor. The applicant claims

in the statement that, for products being tested and certified: it has

no managerial affiliations with any producer, supplier, or vendor; it

has no securities, investments, or stock options in the product lines;

the employment security of its personnel is free from influence by any

producer, supplier, or vendor; that it is not owned, operated, or

controlled by any producers, suppliers, or vendors; and that it is not

engaged in promotion or design.

Creditable Reports/Complaint Handling

Section 1910.7(b)(4) provides that a OSHA recognized NRTL must

maintain effective procedures for producing creditable findings and

reports that are objective and without bias, as well as for handling

complaints and disputes under a fair and reasonable system. The QA

manual contains details on development of test data and reports, and

both the application and the QA manual describe a complaint procedure.

Standards

DTL desires recognition for testing and certification of products

to determine compliance with the following test standards, which are

appropriate within the meaning of 29 CFR 1910.7(c):

ANSI/UL 234--Low Voltage Lighting Fixtures for Use in Recreational

Vehicles

ANSI/UL 1025--Electric Air Heaters

Preliminary Finding

Detroit Testing Laboratory, Inc., addressed all of the criteria

which had to be met for recognition as an NRTL, as summarized above. In

addition, the NRTL Recognition Program staff performed an on-site

review of DTL's main facility and investigated nine major areas:

facility; test equipment; calibration program; test and evaluation

procedures; test reports; records; quality assurance program; follow-up

listing program; and personnel. Any discrepancies noted by the survey

team during the on-site review were adequately responded to following

the on-site evaluation and are included as an integral part of the On-

Site Review Report (see Exhibit 3). With the preparation of the final

report, the Program staff was satisfied that the testing facility

appeared to meet the necessary criteria required by 29 CFR 1910.7, and

recommended that DTL be recognized.

Following a review of the application file and the On-Site Review

Report, the NRTL Recognition Program staff concluded that the applicant

appeared to have met the requirements for recognition as a Nationally

Recognized Testing Laboratory for the Warren, Michigan facility and,

therefore, recommended to the Assistant Secretary that the application

be preliminarily approved.

Based upon a review of the completed application file, the On-Site

Review Report, and the recommendation of the staff, the Assistant

Secretary has made a preliminary finding that Detroit Testing

Laboratory, Inc. can meet the requirements as prescribed by 29 CFR

1910.7 to recognize the Warren, Michigan facility for the two standards

previously listed.

All interested members of the public are invited to supply detailed

reasons and evidence supporting or challenging the sufficiency of the

applicant having met the requirements for recognition as a Nationally

Recognized Testing Laboratory, as well as Appendix A to 29 CFR 1910.7.

Submission of pertinent written documents and exhibits shall be made no

later than January 20, 1998 and must be addressed to the Office of

Variance Determination, NRTL Recognition Program, Occupational Safety

and Health Administration, U.S. Department of Labor, 200 Constitution

Avenue, N.W., Room N 3653, Washington, D.C. 20210. Copies of the DTL

application, the laboratory On-Site Review Report, and all submitted

comments, as received, (Docket No. NRTL-2-97), are available for

inspection and duplication at the Docket Office, Room N 2634,

Occupational Safety and Health Administration, U.S. Department of

Labor, at the above address.

The Assistant Secretary's final decision on whether the applicant

(DTL) satisfies the requirements for recognition as a NRTL will be made

on the basis of the entire record including the public submissions and

any further proceedings that the Assistant Secretary may consider

appropriate in accordance with Appendix A to Section 1910.7.

Authority: 29 CFR 1910.7.

Signed at Washington, DC, this 14th day of November, 1997.

Charles N. Jeffress,

Assistant Secretary.

[FR Doc. 97-30684 Filed 11-20-97; 8:45 am]

BILLING CODE 4510-26-P