Connection of Customer-Provided Terminal Equipment to the Telephone Network

Federal RegisterNov 19, 1997

Ask Donna

What actually matters in this document.

Text

FEDERAL COMMUNICATIONS COMMISSION

47 CFR Part 68

[CC Docket No. 96-28; FCC 97-270]

Connection of Customer-Provided Terminal Equipment to the

Telephone Network

AGENCY: Federal Communications Commission.

ACTION: Final rule.

-----------------------------------------------------------------------

SUMMARY: On August 22, 1997, the Commission released a report and order

adopting final rules to amend the Commissions rules, which govern the

terms and conditions under which customer-provided terminal equipment

may be connected to the telephone network without causing harm to the

public switched network. As a result of the amendments, manufacturers

will be able to test terminal equipment for compliance with a single,

consistent set of technical standards accepted in both the United

States and Canada. The harmonization of terminal attachment rules in

the United States and Canada will be a model for our harmonization

efforts with other countries.

EFFECTIVE DATE: April 20, 1998.

FOR FURTHER INFORMATION CONTACT:

Technical Information: William VonAlven, (202) 418-2342 or email at

[email protected].

Legal Information: Marian Gordon, (202) 418-2320 or email at

[email protected]. The address for both is: Network Services Division,

Common Carrier Bureau, Federal Communications Commission, 2000 M

Street, NW, Suite 235, Washington, DC 20054. The fax number is: (202)

418-2345. The TTY number is: (202) 418-0484.

SUPPLEMENTARY INFORMATION:

I. Introduction

1. In this Report and Order (``Order''), we adopt final rules to

amend part 68 of the Commission's rules, which governs the terms and

conditions under which customer-provided terminal equipment may be

connected to the telephone network without causing harm to the

network.\1\ The amendments we adopt herein are designed to harmonize

United States and Canadian requirements governing connection of

terminal equipment to the public switched network (``PSN'') and to

promote barrier-free trade between Canada and the United States, in

keeping with the spirit of the North American Free Trade Agreement

[[Page 61650]]

(``NAFTA'').\2\ As a result of these amendments to part 68,

manufacturers in one country will be able to design and test terminal

equipment to comply with a single, consistent set of technical

standards accepted in both the United States and Canada.

---------------------------------------------------------------------------

\1\ See 47 CFR part 68. For a history of part 68, see Proposals

for New or Revised Classes of Interstate and Foreign Message Toll

Telephone Service (``MTS'') and Wide Area Telephone Service

(``WATS''); Revision of part 68 of the Commission's rules to Specify

Standard Plugs and Jacks for the Connection of Telephone Equipment

to the Nationwide Telephone Network; and Amendment of Part 68 of the

Commission's rules (Telephone Equipment Registration) to Specify

Standards for and Means of Connection of Telephone Equipment to Lamp

and/or Annunciator Functions of Systems, Memorandum Opinion and

Order, 70 FCC 2d 1800 (1979), 45 FR 20841, Mar. 31, 1980.

\2\ In Canada, certification means the right to attach terminal

equipment to the PSN. Certification requires submission of an

application that includes a technical description of the equipment

and a measurement report showing compliance with CS-03, the Canadian

terminal attachment standard. Canadian requirements for terminal

attachment are issued by Industry Canada (``IC''). Under the

direction of IC, the Terminal Attachment Program Advisory Committee

(``TAPAC''), a government and industry advisory committee, reviews

and recommends changes to equipment certification programs. Canada

amended its terminal attachment rules (CS-03 standards) to harmonize

Canadian standards for terminal equipment with those set forth in

part 68 on August 14, 1996. Canada Gazette, part I, June 15, 1996,

Notice No. SMSE-003-96.

---------------------------------------------------------------------------

II. Background

1. On March 9, 1995, the Telecommunications Industry Association

(``TIA'') filed a Petition for Rulemaking (``Petition'') to amend

Secs. 68.300-68.318 and portions of Sec. 68.2 of the Commission's rules

to harmonize United States network protection standards and

corresponding Canadian CS-03 certification regulations. Subpart D of

part 68, which includes Secs. 68.300 through 68.318, addresses

``Conditions for Registration,'' including requirements for

environmental simulation (simulation ``mimics'' stresses that terminal

equipment undergoes in shipment and handling that could potentially

damage it), leakage current limitations, hazardous voltage limitation,

signal power limitations, longitudinal balance limitations, on hook

impedance limitations, billing protection, and hearing aid

compatibility. Section 68.2 addresses the scope of the Commission's

rules for terminal attachment.

2. TIA is a national trade association with more than 570 member

companies engaged in the manufacture, sale and distribution of

telecommunications equipment including terminal equipment. TIA's

Petition is the culmination of four years of technical effort by United

States and Canadian industry. In September, 1990, TIA's Engineering

Subcommittee TR-41, sponsored by its User Premises Equipment Division,

proposed a project to ``address differences'' between Canadian and

United States terminal attachment rules.\3\ The Subcommittee created a

joint working group co-chaired by representatives from the United

States and Canada to develop a harmonized set of rules to comply with

both countries' requirements for terminal attachment.\4\

---------------------------------------------------------------------------

\3\ TIA's technical work is conducted through its Engineering

Committees, which develop, maintain, and publish voluntary standards

and technical reports. TIA encourages these committees to work

cooperatively with members of the American National Standards

Institute (``ANSI''), as well as international standards bodies

outside the United States, to harmonize telecommunications equipment

standards to avoid duplicating standardization work already

successfully completed. TIA's stated trade policy goals include

``removal of barriers to market access, full participation of United

States government and industry in the standards-setting process

worldwide, and achievement of a minimum level of standards required

to ensure interoperability and proper function of the international

network.'' See TIA Petition at 2.

\4\ According to TIA, a wide range of interest groups in the

United States and Canada were represented including carriers,

manufacturers, laboratories, consultants and government personnel.

---------------------------------------------------------------------------

3. In February 1996, in response to TIA's Petition and comments

received on the petition, the Commission issued a Notice of Proposed

Rulemaking (NPRM) proposing to amend Part 68 to harmonize United States

and Canadian requirements for connection to the PSN.\5\ In the NPRM,

the Commission tentatively concluded that the amended rules would

promote barrier-free trade between the United States and Canada by

eliminating unnecessary differences in terminal attachment

requirements.\6\ We tentatively concluded that the amended rules would

be consistent with the spirit of NAFTA, and might become a guide for

harmonization efforts with other countries.\7\ Furthermore, we

tentatively concluded that the amended rules would create a more

competitive equipment marketplace, resulting in lower costs for

equipment, thereby benefitting United States and Canadian consumers. We

also stated that the proposed rules were consistent with our commitment

to ensure that customers and manufacturers can connect terminal

equipment to the telephone network without causing harm to the

network.\8\ Finally, we tentatively concluded that the Commission must

retain ultimate responsibility for part 68 functions, but should rely

on standards bodies whenever possible to resolve complex technical

matters. We sought comment on these tentative conclusions.\9\

---------------------------------------------------------------------------

\5\ See Public Notice, ``Pleading Cycle Established for Comments

on TIA's Petition for Rulemaking to Amend part 68, Subpart D'', 10

FCC Rcd 4548 (March 27, 1995); Amendment of Part 68 of the

Commission's Rules, Notice of Proposed Rulemaking, 11 FCC Rcd 13282

(1996), 61 FR 15441, Apr. 8, 1996, Erratum, (Mar. 29, 1996)

(``NPRM''). Seven parties filed comments in response to the NPRM. On

April 16, 1996, one party filed reply comments.

\6\ NPRM 11 FCC Rcd at 13295.

\7\ Id. The rules are consistent with the aims of the World

Trade Organization, which like NAFTA, seek to reduce trade barriers

in order to promote competition.

\8\ Id.

\9\ Id.

---------------------------------------------------------------------------

III. Discussion

A. Technical Amendments

4. Positions of the Parties. There is unanimity of opinion among

commenters that harmonization of part 68 and CS-03 will benefit

terminal equipment manufacturers as well as the telecommunications

industry. There were no oppositions to any of the proposed rules.

Northern Telecom (``Nortel''), for example, supports the Commission's

proposal and suggests that harmonization of technical requirements for

attachment of terminal equipment to the PSN will facilitate trade

between the United States and Canada because manufacturers will need to

design and test to only one set of common standards.\10\ Lucent agrees

that the amendment of part 68 will result in commercial advantages.\11\

NYNEX argues that, under the proposed rules, a de facto barrier to

trade that was inconsistent with NAFTA will be eliminated.\12\

Ameritech says that the proposed rules are an example of how ``the

government and industry can achieve agreement without the need for

additional regulation.'' \13\

---------------------------------------------------------------------------

\10\ Nortel Comments at 1; see also VeriFone Comments at 1.

\11\ Lucent Comments at 2.

\12\ NYNEX Comments at 2.

\13\ Ameritech Comments at 1; see also Verifone Comments at 1.

---------------------------------------------------------------------------

5. TIA and Sprint propose editorial corrections to the part 68

rules in attachments to each of their comments.\14\ Additionally,

Sprint argues that the Commission should add any tariffed data rates,

i.e., all speeds of data communications that telephone companies agree

to provide to the public for a requested service, to the amendments to

part 68.\15\ More specifically, Sprint states that 38.4 kbps is an

existing T1 subrate service and as such ``qualifies for protection in

accordance with the purpose of the part 68 rules.'' \16\

---------------------------------------------------------------------------

\14\ Sprint Comments at 1; TIA Comments at 2.

\15\ Sprint Comments at 3.

\16\ Sprint requests that the valid tariffed data rate of 38.4

kbps be included in Sec. 68.308(h)(1)(i), Table 68.308(c), and Table

68.310(b). NPRM, 11 FCC Rcd at 13241-42, 13431, 61 FR 15441, Apr. 8,

1996.

---------------------------------------------------------------------------

6. Discussion. Based on the record, we amend part 68 to harmonize

it with Canada's CS-03 and summarize our amendments as follows. Section

68.302 is designed to protect the network from harm by ensuring that,

despite being subject to environmental stresses, terminal equipment

will continue to comply with part 68 and not harm the

[[Page 61651]]

network. Amended Sec. 68.302 deletes vibration, temperature, and

humidity stresses from part 68, and applies mechanical shock stresses

only to equipment that might be affected by such stress. We delete

these stresses because experience has shown, and the record supports,

that they are unnecessary given the technological evolution in telecom

equipment from an arrangement of discrete electronic components to

solid state circuitry. Over the past ten years, failures during part 68

registration testing involving these stresses is negligible. The

benefits of streamlining our regulations in this regard far outweigh

any possible harm to the network created by these stresses. In

addition, as the result of industry coordination, we are including a

new Type B surge test to better assure operability of customer premises

equipment during lightning storms.

7. Section 68.304 leakage current limitations ensure that telephone

connections are adequately insulated against hazards to telephone

company personnel caused by voltages within the equipment itself or as

a result of accidental contact with commercial power sources.

Previously, Sec. 68.304 required testing using a 60 Hertz test voltage.

Amended Sec. 68.304 changes the 60 Hertz standard to either 50 or 60

Hertz to harmonize with international frequencies used for this purpose

and with Underwriters Laboratories and Canadian Standards Association

insulation standards.

8. Section 68.306 imposes ``fail safe'' requirements on hazardous

voltage. These limits are generally used throughout the telephone

industry as voltage limitations below which special protection of

telephone craft personnel is not required. Equipment must be designed

to avoid creating voltages exceeding these limits under normal

operation. We amend this section to delete hazardous voltage

requirements for Message Registration (``MR'') and Automatic

Identification of Outward Dialing (``AIOD'') because these types of

technology are no longer in use.\17\ In addition, this Order changes

the current voltage limitation from 80 to 60 volts to harmonize it with

international safety standards.

---------------------------------------------------------------------------

\17\ Message Registration (``MR'') was a specific traffic

recording system provided by certain older types of telephone

systems. Automatic Identification of Outward Dialing (``AIOD'') was

a private branch exchange (PBX) service feature that identified the

calling line on calls directed to a public switched telephone

network for automatic message accounting recording purposes.

---------------------------------------------------------------------------

9. The signal power limitations of Sec. 68.308 are designed to

protect the network from interference caused by excessive signal power.

We update this section by revising the ``Through Gain'' Table to

reflect services such as Integrated Services Digital Network (``ISDN'')

and to delete references to the 4-wire Conventional Termination Set

interface.\18\ We also expand subrate digital channel rates to include

all rates presently used by industry, and adopt the ANSI T1 standard to

replace the standard in the previous rules.\19\ Section 68.308 also

protects the network from harm by addressing crosstalk interference. We

reword this section for clarity and rename this section ``Transverse

Balance Limitations'' to harmonize it with internationally recognized

Institute of Electrical and Electronic Engineers' (``IEEE'')

terminology.

---------------------------------------------------------------------------

\18\ The Through Gain Table shows the maximum net amplification

permitted in multiport systems between ports. The 4-wire

Conventional Terminating Set interface was an older technology used

for connection of customer provided equipment to analog voiceband

private line services.

\19\ Subrate digital channel rates previously used by the

industry ranged from 2.4 to 64 kilobits/second (kbps).

---------------------------------------------------------------------------

10. Section 68.312 addresses the impedance (i.e., the resistance a

circuit offers to alternating current) that must be maintained on a

telephone line. The amended rules reorganize and reword this section

for clarity. Specifically, the amended rules reduce the categories of

ringer types. We also delete those sections addressing message

registration because this technology is no longer in use.

11. Section 68.314 ensures that transmission of signals in the

network does not interfere with proper operation of network billing

equipment. The amendments to this section include rewording the section

for clarity and deleting operating requirements for AIOD because the

technology has been replaced. We also add a new section to clarify

reverse battery billing (a type of loop signaling) requirements.

Section 68.316 Hearing Aid Compatibility requirements are not amended

by this Order. Furthermore, we delete reference to 1.544 Mbps digital

``keep-alive'' requirements from Sec. 68.318 because they are no longer

in effect.\20\ Finally, we amend definitions in Sec. 68.3. For example,

we delete references to MR and AIOD equipment, but clarify that any MR

and AIOD equipment that remains connected to the network may continue

to be used under the provisions of Sec. 68.2.

---------------------------------------------------------------------------

\20\ Keep-alive refers to constantly present direct current

voltage formally provided from the central office. Section 68.318

previously stated that ``(u)ntil December 18, 1989, terminal

equipment connecting to 1.544 Mbps services shall contain circuitry

that assures continuity of output signal.''

---------------------------------------------------------------------------

12. The record supports our tentative conclusion that amendment of

part 68 as described above should lower the price consumers pay for

terminal equipment by facilitating greater efficiencies in the

manufacturing and testing of terminal equipment. Under the amended

rules, the technical requirements of part 68 and CS-03 would be

harmonized so that a manufacturer in one country can design and test

terminal equipment to a single, consistent set of technical standards

accepted in both the United States or Canada. We conclude that these

efficiencies will lead to an even more competitive market for terminal

equipment than currently exists, resulting in lower costs for

equipment, thus benefitting United States and Canadian consumers.

13. Moreover, as commenters recognize, the amendments to part 68

reconcile differences in standards and testing consistent with NAFTA.

Currently, terminal equipment manufactured for use in the United States

must meet the technical requirements of part 68. Similarly, terminal

equipment manufactured for use in Canada must comply with the technical

requirements contained in CS-03. Each country's respective technical

requirements have differed sufficiently that terminal equipment

complying with one set of regulations would not necessarily comply with

the technical requirements of the other country. These differences, as

NYNEX correctly states, have created unreasonable burdens on

manufacturers and are a de facto barrier to trade inconsistent with the

goals of NAFTA. By reconciling differences in standards and testing,

harmonization promotes the goals of NAFTA.\21\ Furthermore, the record

supports our tentative conclusion that, as amended, the rules remain

consistent with the Commission's longstanding commitment to ensure that

no public harm results from attachment of private equipment to the PSN.

The record is unanimous that the amended

[[Page 61652]]

rules in no way diminish network protection.

---------------------------------------------------------------------------

\21\ At a February 1997 meeting of the Telecommunications

Standards Subcommittee (``TSSC''), Mexico agreed to a ``Minimal''

set of network protection standards pursuant to NAFTA Article 1304-1

(with minor exceptions to accommodate national deviations in

networks) consistent with our initiative here to harmonize United

States and Canadian network protection standards. The TSSC was

established under NAFTA (Article 913) to creat a work plan for

``making compatible the standards-related measures for authorized

equipment.'' It is comprised of officials from NAFTA member

countries.

---------------------------------------------------------------------------

14. Finally, we have reviewed the editorial corrections proposed by

TIA and Sprint and find that they clarify our rules. For this reason,

our final rules incorporate these suggested changes. In addition, we

have added the tariffed data rate that Sprint suggests to our rules.

While we decline to require that all tariffed rates be included, we

agree that the specific tariffed rate Sprint suggests should be

included to cover its currently available service.

B. Grandfathering Provision

15. Positions of the Parties. Lucent argues that the Commission

should amend Sec. 68.2(j) to ``provide grandfathering for existing

equipment, in order to avoid any requirement to re-register all the

equipment that has already been registered under current rules.'' \22\

Lucent argues that a grandfathering provision is necessary to avoid re-

registration of products that are already registered under current

rules, are in use, and do not cause harm to the network. Several of the

commenters add that re-registration of these products would impose

substantial expense without yielding any benefits. We note that no

party has objected to a grandfathering provision.

---------------------------------------------------------------------------

\22\ Lucent Comments at 2; see also TIA Comments at 2-3.

---------------------------------------------------------------------------

16. Discussion. We are persuaded by commenters that there would be

no benefit to requiring the re-registration of equipment already in use

and shown not to cause harm to the network. We therefore adopt a

grandfathering provision.\23\ The new rule 68.2(j) reads as follows:

\23\ We note, however, that based on past experience, the vast

majority of equipment covered by the grandfathering rule will be

phased out of production and replaced by models that will be subject

to the new rules.

---------------------------------------------------------------------------

Terminal equipment and systems registered prior to April 20,

1998, do not have to be re-registered unless subsequently modified.

All new equipment and systems manufactured after May 19, 1999, must

conform to the requirements.

C. Regulatory Process

17. Background. In the NPRM, we stated that although harmonization

of technical requirements for attachment of terminal equipment

satisfies NAFTA requirements in a manner consistent with the interests

of United States industry in facilitating greater efficiencies in

manufacturing terminal equipment, we recognized that the usefulness of

a harmonized standard is jeopardized if our regulatory process does not

allow the standard to evolve at the same pace as technology.\24\

Consequently, we tentatively concluded that the Commission should rely,

whenever possible, on standards bodies to resolve complex technical

issues. We stated our reluctance, however, to substitute industry

consensus for our part 68 rulemaking function as such consensus may not

always promote the public interest.\25\ We noted that standards bodies

often lack the Commission's authority to ensure compliance with fair

rules supporting safe and direct electrical connection of subscriber's

terminal equipment to the PSN.\26\

---------------------------------------------------------------------------

\24\ NPRM, 11 FCC Rcd at 13294.

\25\ Id. at 13295.

\26\ Id.

---------------------------------------------------------------------------

18. Positions of the Parties. TIA and NYNEX urge the Commission to

adopt a rule requiring manufacturers to comply with the technical

recommendations of industry standards bodies with appropriate

Commission oversight. NYNEX states that ``(i)nstead of specifying

technical interfaces and requirements for terminal equipment in the

rules, the Commission should simply adopt a rule that requires

manufacturers of such equipment to comply with the technical

requirements and technical recommendations developed by appropriate

industry standards bodies under the Commission's auspices * * * .''

\27\ NYNEX contends that through its oversight of industry standards

bodies, the Commission should be satisfied as to the ``reasonableness''

of any resulting technical recommendations. TIA argues that the current

regulatory rulemaking process lags behind changes in technology and

supports NYNEX's proposal.\28\ Moreover, TIA states that NYNEX's

suggested approach would be consistent with recent congressional

directives.\29\ VeriFone contends that industry standards bodies should

remain responsible for technical issues, but concurs with the

Commission's decision to retain ultimate responsibility in matters

pertaining to part 68 rulemaking authority.

---------------------------------------------------------------------------

\27\ NYNEX Comments at 3.

\28\ TIA Comments at 3; TIA Reply Comments at 3-5.

\29\ See, e.g., National Technology Transfer and Advancement Act

of 1995, Pub. L. 104-113, sec. 12, 110 Stat. 775, 782-83 (1996).

---------------------------------------------------------------------------

19. Discussion. We acknowledge that efforts to harmonize our

terminal attachment rules with those of other countries will be impeded

if the regulatory rulemaking process fails to keep pace with

technological changes. Therefore, we conclude that the Commission

should rely, whenever possible, on standards bodies composed of

industry experts to resolve complex technical matters. As we stated in

the NPRM, the Consultative Committee on Telecommunications (``CCT'')

has substantially assisted various harmonization activities.\30\

Additionally, we recently sought comment on whether standards for

enhanced wire quality and for determining gold equivalence should be

permanent standards and, if so, what industry body or bodies shall

determine an appropriate voluntary standard.\31\ We decline, however,

to substitute industry consensus completely for our part 68 rulemaking

function. While they often may most expeditiously resolve complex

technical matters, standards bodies lack the Commission's authority to

ensure compliance with fair rules supporting safe and direct electrical

connection of subscribers' telephone terminal equipment to the PSN. We

note, for example, that new section 273(d)(4) of the Communications Act

of 1934, as amended, seeks to ensure that voluntary standards do not

become de facto standards that operate to exclude legitimate parties.

Similarly, while it in this proceeding has strived to incorporate the

advice and assistance of standards bodies to resolve complex technical

matters, the Commission must continue to ensure through its rulemaking

function that fair rules are developed.

---------------------------------------------------------------------------

\30\ NPRM, 11 FCC Rcd at 13294.

\31\ Review of Secs. 68.104 and 68.213 of the Commission's Rules

Concerning Connection of Simple Inside Wiring to the Telephone

Network, Order on Reconsideration, Second Report and Order and

Second Further Notice of Proposed Rulemaking, CC Docket No. 88-57,

FCC 97-209 (June 17, 1997), at paras. 54-55, 62 FR 36463, Jul. 8,

1997.

---------------------------------------------------------------------------

IV. Conclusion

20. We conclude that the rules we adopt herein will eliminate

unnecessary differences in terminal attachment requirements, and

thereby promote barrier-free trade, between the United States and

Canada. We find this to be consistent with the spirit and letter of

NAFTA, which mandates elimination of trade barriers through

reconciliation of differences in standards and testing procedures.

These rules may become a model for our harmonization efforts with

countries around the world and should benefit consumers by creating a

more competitive equipment marketplace, thereby lowering the prices

they pay for equipment. We conclude that these rules are consistent

with the Commission's long-standing commitment to ensure that no public

harm results from attachment of private

[[Page 61653]]

equipment to the public switched network.

V. Regulatory Flexibility Analysis

21. Final Regulatory Analysis: As required by the Regulatory

Flexibility Act (``RFA''),\32\ an Initial Regulatory Flexibility

Analysis (``IRFA'') was incorporated in the Notice of Proposed

Rulemaking in this proceeding, 11 FCC Rcd 13282 (1996); Erratum,

(released March 29, 1996) (``NPRM''). The Commission sought written

public comments on the proposals in the NPRM, including comment on the

IRFA. This present Final Regulatory Flexibility Analysis (``FRFA'') in

this Report and Order (``Order'') conforms to the RFA.

---------------------------------------------------------------------------

\32\ See 5 U.S.C. 603. The RFA, see 5 U.S.C. 601 et seq., has

been amended by the Contract With America Advancement Act of 1996,

Pub. L. 104-121, 110 Stat. 847 (1996) (CWAAA). Title II of the CWAA

is the Small Business Regulatory Enforcement Fairness Act of 1996

(SBREFA).

---------------------------------------------------------------------------

Need for, and Objectives of, This Order and the Rules Adopted Herein

22. Consistent with the intent of the North American Free Trade

Agreement (``NAFTA''), this Order amends part 68 of the Commission's

rules to promote barrier-free trade between the United States and

Canada. Part 68 governs the terms and conditions under which customer

provided terminal equipment may be connected to the telephone network.

As a result of the amendments to part 68, manufacturers will be able to

test terminal equipment for compliance with a single, consistent set of

technical standards accepted in both the United States and Canada. The

harmonization of terminal attachment rules in the United States and

Canada will be a model for our harmonization efforts with other

countries. We adopt a grandfathering provision to cover equipment

already registered under current rules.

Summary of Significant Issues Raised by Public Comments in Response to

the IRFA

23. No comments were submitted specifically in response to the

IRFA. We have reviewed the general comments to identify issues that may

have a significant economic impact on small businesses. All commenters

addressing the proposed amendments to part 68 of our Rules supported

the amendments.

Description and Estimate of the Number of Small Entities To Which Rules

Will Apply

24. The RFA directs the Commission to provide a description of and,

where feasible, an estimate of the number of small entities that will

be affected by the proposed rules. The RFA defines the term ``small

entity'' as having the same meaning as the terms ``small business,''

``small organization,'' and ``small business concern'' under section 3

of the Small Business Act.\33\ A small business concern is one which:

(1) Is independently owned and operated; (2) is not dominant in its

field of operation; and (3) satisfies any additional criteria

established by the SBA.\34\ SBA has defined a small business for

Standard Industrial Classification (``SIC'') category 4813 (Telephone

Communications), Except Radiotelephone) to be a small entity when it

has no more than 1,500 employees.\35\

---------------------------------------------------------------------------

\33\ See 5 U.S.C. 601(3) (incorporating by reference the

definition of ``small business concern'' in 5 U.S.C. 632).

\34\ 15 U.S.C. 632.

\35\ See 13 CFR 121.201.

---------------------------------------------------------------------------

25. Consistent with our prior practice, we here exclude small

incumbent local exchange carriers (LECs) from the definition of small

entity and small business concern. While such a company may have 1500

or fewer employees and thus fall within the SBA's definition of a small

telecommunications entity, such companies are either dominant in their

field of operations or are not independently owned and operated. Out of

an abundance of caution, however, for regulatory flexibility analysis

purposes, we will consider small incumbent LECs within this present

analysis and use the term ``small incumbent LECs'' to refer to any

incumbent LEC that arguably might be defined by SBA as a small business

concern.

26. Manufacturers of Telecommunications Equipment: The Commission

has not developed a definition of small manufacturers of terminal

equipment. The closest applicable definition under SBA rules is for

manufacturers of telephone and telegraph apparatus (SIC 3661), which

defines a small manufacturer as one having 1000 or fewer employees.\36\

According to 1992 Census Bureau data, there were 479 such

manufacturers, and of those, 436 had 999 or fewer employees, and 7 had

between 1000 and 1499 employees.\37\ Consequently, we estimate that

there are fewer than 443 small manufacturers of terminal equipment that

may be affected by the decision and rules adopted in this Order.

---------------------------------------------------------------------------

\36\ 13 CFR 121.201, SIC 3661.

\37\ 1992 Economic Census, Industry and Employment Size of Firm,

Table 1D (data prepared by U.S. Census Bureau under contract to the

U.S. Small Business Administration).

---------------------------------------------------------------------------

Description of Projected Reporting, Recordkeeping and Other Compliance

Requirements

27. There are no reporting or recordkeeping requirements.

Manufacturers will be required to test terminal equipment to a single,

consistent set of technical standards accepted in both the United

States and Canada.

Steps Taken to Minimize Significant Economic Impact on Small Entities,

and Significant Alternatives Considered

28. We are adopting Sec. 68.2(j), which states that equipment

already registered under the current rules does not need to be re-

registered under the new rules. We believe that such a provision will

save manufacturers, some of which may be small businesses, the expenses

incurred in re-registering equipment that is already in use and has

been shown not to cause harm to the network.\38\ No alternative to this

beneficial action was suggested.

---------------------------------------------------------------------------

\38\ The rule changes ameliorate potential technical barriers to

entry in both the U.S. and Canada markets, thereby allowing

manufacturers and suppliers, including small manufacturers and

suppliers, a reasonable opportunity to conduct business in both

markets. This result in consistent with the general purposes of

section 257 of the 1996 Telecommunications Act, 47 U.S.C. 257. That

section requires, among other things, that the Commission eliminate

market entry barriers for small businesses who may provide parts or

services to providers of telecommunications services and information

services. Id. at section 257(a). The Commission recently issued a

report in GN Docket No. 96-113 regarding its implementation of

Section 257. See Section 257 Proceeding to Identify and Eliminate

Market Entry Barriers for Small Businesses, Report No. 97-8, 1997 WL

232120 (1997).

---------------------------------------------------------------------------

Report to Congress

29. The Commission will send a copy of the Order, including this

FRFA, in a report to be sent to Congress pursuant to the Small Business

Regulatory Enforcement Fairness Act of 1996, see 5 U.S.C. 801(a)(1)(A).

A copy of the Order and this FRFA (or summary thereof) will also be

published in the Federal Register, see 5 U.S.C. 604(b), and will be

sent to the Chief Counsel for Advocacy of the Small Business

Administration.

VI. Ordering Clauses

30. Accordingly, it is ordered that, pursuant to sections 1, 4,

201-205, 218, 220, 226, 227, 255, and 710 of the Communications Act of

1934, as amended, 47 U.S.C. 151, 154, 201-205, 218, 220, 226, 227, 255,

and 610, and 5 U.S.C. 552 and 553, this Report and Order is adopted,

and part 68 of the

[[Page 61654]]

Commission's rules are amended as set forth below.

31. It is further ordered, that the rule amendments set forth below

shall be effective April 20, 1997.

32. It is further ordered, that the Commission shall send a copy of

this Order, including the Final Regulatory Flexibility Analysis, to the

Chief Counsel for Advocacy of the Small Business Administration.

List of Subjects in 47 CFR Part 68

Administrative practice and procedure, Communications common

carriers, Communications equipment, Telephone.

Federal Communications Commission.

William F. Caton,

Acting Secretary.

47 CFR part 68 is amended as follows:

PART 68--CONNECTION OF TERMINAL EQUIPMENT TO THE TELEPHONE NETWORK

1. The authority citation for part 68 continues to read as follows:

Authority: Sec. 1, 4, 5, 201-5, 208, 215, 218, 226, 227, 303,

313, 314, 403, 404, 410, 522 of the Communications Act of 1934, as

amended, 47 U.S.C. 151, 154, 155, 201-5, 208, 215, 218, 226, 227,

303, 313, 314, 403, 404, 410, 522.

2. Section 68.2 is amended by revising paragraphs (a)(3); (d),

introductory text, and paragraph (j) and adding new paragraph (d)(4) to

read as follows:

Sec. 68.2 Scope.

(a) * * *

(3) Of all PBX (or similar) systems to private line services for

tie trunk type interfaces and off premises station lines. Services may

only be added to this section as a result of rulemaking proceedings and

equipment connected to such added services is afforded a reasonable

transition period.

* * * * *

(d) Grandfathered private branch exchange (or similar) systems for

connection to private line type services (tie trunk type services, off-

premises station lines automatic identified outward dialing, and

message registration):

* * * * *

(4) PBX (or similar) systems connected with automatic identified

outward dialing or message registration private line services of a type

that complies with paragraphs (d)(l) and (d)(2) of this section may

remain connected for life without registration unless subsequently

modified.

* * * * *

(j) Terminal equipment including premises wiring and protective

apparatus (if any) directly connected to the network on April 20, 1997,

may remain connected and be reconnected for life without registration,

unless subsequently modified. New installations of terminal equipment,

including premises wiring and protective apparatus (if any) may be

installed (including additions to existing systems) up to May 19, 1999,

without registration of any terminal equipment involved, provided that

the terminal equipment is of a type directly connected to the network

as of April 20, 1998. This terminal equipment may remain connected and

be reconnected to the network for life without registration, unless

subsequently modified.

* * * * *

3. Section 68.3 is amended by adding the following definitions for

Capture Level, Dual Tone Multi Frequency (DTMF), Overload Point, and

Voiceband in alphabetical order; by revising the definition for ``Zero

Level Decoder''; removing the definitions for AOID Data Channel

Simulator, AIOD Leads, Message Register Leads, Message Register

Signaling Channel Simulator; in the definition for Tie Trunk

Transmission Interfaces, by removing paragraph (c) 4-wire Conventional

Terminating Set (CTS); removing figures 68.3(a), 68.3(f), 68.3(g),

68.3(h), 68.3(i), 68.3(j), 68.3(k), 68.3(l) and 68.3(m) and adding in

their place Figures 68.3(a), 68.3(f), 68.3(g), 68.3(h), 68.3(i),

68.3(j) and 68.3(k). Figure references are corrected in the following

definitions: In Local Area Data Channel Simulator, Figure 68.3(k) is

revised to read Figure 68.3(i), and in Loop Simulator Circuit, Figure

68.3(i) is revised to read Figure 68.3(g) and Figure 68.3(j) is revised

to read Figure 68.3(h).

Sec. 68.3 Definitions.

* * * * *

Capture Level: Equipment with AGC (Automatic Gain Control) signal

power limiting has virtually no output signal for input levels below a

certain value. At some input signal power, the output level will become

significant (usually corresponding to the expected output level) for

the service application. The input level at which this occurs is

defined as the ``capture level.''

* * * * *

Dual Tone Multi Frequency (DTMF) network control signalling is a

method of signalling using the voice transmission path. The method

employs sixteen (16) distinct signals each composed of two (2)

voiceband frequencies, one from each of two (2) geometrically spaced

groups designated ``low group'' and ``high group.'' The selected

spacing assures that no two frequencies of any group combination are

harmonically related.

* * * * *

Overload Point: (1) For signal power limiting circuits

incorporating automatic gain control method, the ``overload point'' is

the value of the input signal that is 15 dB greater than the capture

level.

(2) For signal power limiting circuits incorporating peak limiting

method, the ``overload point'' is defined as the input level at which

the equipment's through gain decreases by 0.4 dB from its nominal

constant gain.

* * * * *

Voiceband: The voiceband for analog interfaces is the frequency

band from 200 Hz to 3995 Hz.

* * * * *

Zero Level Decoder: The zero level decoder shall comply with the

u=255 PCM encoding law as specified in ITU-TSS (CCITT) Rec. G.711 for

voiceband encoding and decoding. See also Fig. 68.3(j).

* * * * *

BILLING CODE 6712-01-P

[[Page 61655]]

[GRAPHIC] [TIFF OMITTED] TR19NO97.000

[[Page 61656]]

[GRAPHIC] [TIFF OMITTED] TR19NO97.001

[[Page 61657]]

[GRAPHIC] [TIFF OMITTED] TR19NO97.002

[[Page 61658]]

[GRAPHIC] [TIFF OMITTED] TR19NO97.003

[[Page 61659]]

[GRAPHIC] [TIFF OMITTED] TR19NO97.004

[[Page 61660]]

[GRAPHIC] [TIFF OMITTED] TR19NO97.005

[[Page 61661]]

[GRAPHIC] [TIFF OMITTED] TR19NO97.006

[[Page 61662]]

[GRAPHIC] [TIFF OMITTED] TR19NO97.007

[[Page 61663]]

[GRAPHIC] [TIFF OMITTED] TR19NO97.008

BILLING CODE 6712-01-C

[[Page 61664]]

Sec. 68.222 [Removed]

4. Section 68.222 is removed.

5. Section 68.300 is revised to read as follows:

Sec. 68.300 Labeling requirements.

(a) Registered terminal equipment and registered protective

circuitry shall have prominently displayed on an outside surface the

following information in the following format:

Complies With Part 68, FCC Rules

FCC Registration Number: __________

Ringer Equivalence: ________________

(b) Registered terminal equipment and registered protective

circuitry shall also have the following identifying information

permanently affixed to it.

(1) Grantee's name.

(2) Model number, as specified in the registration application.

(3) Serial number or date of manufacture.

(4) Country of origin of the equipment: ``Made in __________.''

Required if the equipment is not manufactured in the United States.

(Country of origin shall be determined in accordance with 19 U.S.C.

1304 and regulations promulgated thereunder.)

(5) As used herein, permanently affixed means that the required

nameplate data is etched, engraved, stamped, indelibly printed or

otherwise permanently marked. Alternatively, the required information

may be permanently marked on a nameplate of metal, plastic, or other

material fastened to the enclosure by welding, riveting, or with a

permanent adhesive. Such a nameplate must be able to last for the

expected lifetime of the equipment and must not be readily detachable.

(6) When the device is so small or for such use that it is not

practical to place the statements specified in this section on it, the

information required by paragraphs (a) and (b) of this section shall be

placed in a prominent location in the instruction manual or pamphlet

supplied to the user. The FCC Registration Number and the Model Number

shall be displayed on the device.

6. Section 68.302 is revised to read as follows:

Sec. 68.302 Environmental simulation.

Unpackaged Registered Terminal Equipment and Registered Protective

Circuitry shall comply with all the rules specified in this subpart,

both prior to and after the application of the mechanical and

electrical stresses specified in this section, notwithstanding that

certain of these stresses may result in partial or total destruction of

the equipment. Both telephone line surges, Type A and Type B, shall be

applied as specified in paragraphs (b) and (c) of this section.

Different failure criteria apply for each surge type.

(a) Mechanical shock. (1) Hand-Held Items Normally Used at Head

Height: 18 random drops from a height of 1.5 meters onto concrete

covered with 3 millimeters asphalt tile or similar surface.

(2) Table (Desk) Top Equipment 0-5 kilograms: Six random drops from

a height of 750 millimeters onto concrete covered with 3 millimeters

asphalt tile or similar surface.

(3) The drop tests specified in the mechanical shock conditioning

stresses shall be performed as follows: The unit should be positioned

prior to release to ensure as nearly as possible that for every six

drops there is one impact on each of the major surfaces and that the

surface to be struck is approximately parallel to the impact surface.

(b) Telephone Line Surge--Type A.--(1) Metallic. Apply two metallic

voltage surges (one of each polarity) between any pair of connections

on which lightning surges may occur; this includes:

(i) Tip to ring;

(ii) Tip 1 to ring 1; and

(iii) For a 4-wire connection that uses simplexed pairs for

signalling, tip to ring 1 and ring to tip 1.

Note to paragraph (b)(1). The surge shall have an open circuit

voltage waveform in accordance with Figure 68.302(b) having a front

time (tf)) of 10 s maximum and a decay time

(td) of 560 s minimum, and shall have a short

circuit current waveshape in accordance with Figure 68.302(c) having

a front time (tf) of 10 ms maximum and a decay time

(td) of 560 s minimum. The peak voltage shall be

at least 800 volts and the peak short circuit current shall be at

least 100 amperes. Surges are applied:

(A) With the equipment in all states that can affect compliance

with the requirements of this part 68. If an equipment state cannot

be achieved by normal means of power, it may be achieved

artificially;

(B) With equipment leads not being surged (including telephone

connections, auxiliary leads, and terminals for connection to non-

registered equipment) terminated in a manner that occurs in normal

use;

(C) Under reasonably foreseeable disconnection of primary power

sources, with primary power cords plugged and unplugged, if so

configured.

(2) Longitudinal. Apply two longitudinal voltage surges (one of

each polarity) from any pair of connections on which lightning surges

may occur. This includes the tip-ring pair and the tip 1--ring 1 pair,

to earth grounding connections, and to all leads intended for

connection to non-registered equipment, connected together. Surges are

applied as follows:

(i) With the equipment in all states that can affect compliance

with the requirements of this part 68. If an equipment state cannot be

achieved by normal means of power, it may be achieved artificially;

(ii) With equipment leads not being surged (including telephone

connections, auxiliary leads, and terminals for connection to non-

registered equipment) terminated in a manner that occurs in normal use;

(iii) Under reasonably foreseeable disconnection of primary power

sources, as for example, with primary power cords plugged and

unplugged.

Note to paragraph (b)(2): The surge shall have an open circuit

voltage waveform in accordance with Figure 68.302(b) with a front

time (tf) of 10 ms (seconds) maximum

and a decay time (td) of 160 ms minimum, and shall have a

short circuit current waveshape in accordance with Figure 68.302(c)

having a front time (tf) of 10 ms maximum and a decay

time (td) of 160 ms minimum. The peak voltage shall be at

least 1500 volts and the peak short circuit current shall be at

least 200 amperes.

(3) Failure Modes resulting from application of Type A telephone

line surges. Regardless of operating state, equipment and circuitry are

allowed to be in violation of the longitudinal balance requirements of

Sec. 68.310(b) and (c) and, for terminal equipment connected to Local

Area Data Channels, the longitudinal signal power requirements of Sec.

68.308(f)(3), if:

(i) Such failure results from an intentional, designed failure mode

that has the effect of connecting telephone or auxiliary connections

with earth ground; and,

(ii) If such a failure mode state is reached, the equipment is

designed so that it would become substantially and noticeably unusable

by the user, or an indication is given (e.g., an alarm), in order that

such equipment can be immediately disconnected or repaired.

Note to paragraph (b)(3)(ii): The objective of paragraph

(b)(3)(ii) is to allow for safety circuitry to either open-circuit,

which would cause a permanent on-hook condition, or to short-circuit

to ground, as a result of an energetic lightning surge. Off-hook

tests would be unwarranted if the off-hook state cannot be achieved.

A short to ground has the potential for causing interference

resulting from longitudinal imbalance, and therefore designs must be

adopted which will cause the equipment either to be disconnected or

repaired rapidly after such a state is reached, should it occur in

service.

(c) Telephone Line Surge--Type B.--(1) Metallic. Apply two metallic

voltage surges (one of each polarity) to equipment between any pair of

[[Page 61665]]

connections on which lightning surges may occur; this includes:

(i) Tip to ring;

(ii) Tip 1 to ring 1; and

(iii) For a 4-wire connection that uses simplexed pairs for

signalling, tip to ring 1 and ring to tip 1.

Note to paragraph (c)(1): The surge shall have an open circuit

voltage waveform in accordance with Figure 68.302(b) having a front

time (tf) of 9 ms (30%) and a decay time

(td) of 720 s (20%) and shall have a

short circuit current waveshape in accordance with Figure 68.302(c)

having a front time (tf) of 5 ms (30%) and a

decay time (td) of 320 s (20%). The

peak voltage shall be at least 1000 volts and the peak short circuit

current shall be at least 25 amperes. The wave shapes are based on

the use of ideal components in Figure 68.302(a) with S2

in Position M. Surges are applied:

(A) With the equipment in all states that can affect compliance

with the requirements of this part 68. If an equipment state cannot

be achieved by normal means of power, it may be achieved

artificially.

(B) With equipment leads not being surged (including telephone

connections, auxiliary leads, and terminals for connection to non-

registered equipment) terminated in a manner that occurs in normal

use.

(C) Under reasonably foreseeable disconnection of primary power

sources, as for example, with primary power cords plugged and

unplugged.

(2) Longitudinal. Apply two longitudinal voltage surges (one of

each polarity) from any pair of connections on which lightning surges

may occur. This includes the tip-ring pair and the tip 1--ring 1 pair

to earth grounding connections and to all leads intended for connection

to non-registered equipment, connected together. Surges are applied as

follows:

(i) With the equipment in all states that can affect compliance

with the requirements of this part 68. If an equipment state cannot be

achieved by normal means of power, it may be achieved artificially.

(ii) With equipment leads not being surged (including telephone

connections, auxiliary leads, and terminals for connection to non-

registered equipment) terminated in a manner that occurs in normal use.

(iii) Under reasonably foreseeable disconnection of primary power

sources, with primary power cords plugged and unplugged, if so

configured.

Note to paragraph (c)(2): For each output lead of the surge

generator, with the other lead open, the surge shall have an open

circuit voltage waveform in accordance with Figure 68.302(b) having

a front time (tf) of 9 s (30%) and a

decay time (td) of 720 s ( 20%) and

shall have a short circuit current waveshape in accordance with

Figure 68.302(c) having a front time (tf) of 5 s

(30%) and a decay time (td) of 320 s

(20%). The peak voltage shall be at least 1500 volts and

the peak short circuit current shall be at least 37.5 amperes. The

wave shapes are based on the use of ideal components in Figure

68.302)(a) with S2 in Position L.

(3) Failure Modes resulting from application of Type B telephone

line surges. Registered terminal equipment and registered protective

circuitry shall be capable of withstanding the energy of Surge Type B

without causing permanent opening or shorting of the interface circuit

and without sustaining damage that will affect compliance with these

rules.

BILLING CODE 6712-01-P

[[Page 61666]]

[GRAPHIC] [TIFF OMITTED] TR19NO97.009

BILLING CODE 6712-01-C

[[Page 61667]]

(d) Power Line Surge. (1) Apply six power line surges (three of

each polarity) between the phase and neutral terminals of the ac power

line while the equipment is being powered. The surge shall have an open

circuit voltage waveform in accordance with Figure 68.302(b) having a

front time (tf) of 2 s maximum and a decay time

(td) of 10 s minimum and shall have a short circuit

current waveshape in accordance with Figure 68.302(c) with a front time

(tf) of 2 s maximum and a decay time

(td) of 10 s minimum. The peak voltage shall be at

least 2500 volts and the peak short circuit current shall be at least

1000 amperes. Surges are applied:

(i) With the equipment in all states that can affect compliance

with the requirements of this part 68. If an equipment state cannot be

achieved by normal means of power, it may be achieved artificially;

(ii) With equipment leads not being surged (including telephone

connections, auxiliary leads, and terminals for connection to non-

registered/non-certified equipment) terminated in a manner which occurs

in normal use.

(2) Failure Modes resulting from application of power line surge.

Registered terminal equipment and registered protective circuitry shall

comply with all the criteria contained in the rules and regulations in

this subpart, both prior to and after the application of the power line

surge specified in paragraph (d )of this section, not withstanding that

this surge may result in partial or total destruction of the equipment

under test.

8. Section 68.304 is revised to read as follows:

Sec. 68.304 Leakage current limitations.

Registered terminal equipment and registered protective circuitry

shall have a voltage applied to the combination of points listed in the

table below. The test voltage shall be ac of 50 or 60 Hz rms.

(a) All telephone connections;

(b) All power connections;

(c) All possible combinations of exposed conductive surfaces on the

exterior of such equipment or circuitry including grounding connection

points, but excluding terminals for connection to other terminal

equipment;

(d) All terminals for connection to registered protective circuitry

or non-registered equipment;

(e) All auxiliary lead terminals;

(f) All E&M lead terminals, and

(g) All PR, PC, CY1 and CY2 leads.

Table 68.304(a).--Voltage Applied for Various Combinations of Electrical

Connections

------------------------------------------------------------------------

ac

Voltage source connected between: value\1\

------------------------------------------------------------------------

(a) and (b) (see NOTES 1, 2, 3)............................... 1500

(a) and (c) (see NOTES 1, 2).................................. 1000

(a) and (d) (see NOTES 1, 2).................................. 1000

(a) and (e) (see NOTES 1, 2).................................. 1000

(a) and (f) (see NOTES 1, 2).................................. 1000

(a) and (g) (see NOTES 1, 2).................................. 1000

(b) and (c) (see NOTE 3)...................................... 1500

(b) and (d) (see NOTE 3)...................................... 1500

(b) and (e) (see NOTE 3)...................................... 1500

(b) and (f) (see NOTE 3)...................................... 1500

(b) and (g) (see NOTE 3)...................................... 1500

(c) and (e) (see NOTES 1, 2).................................. 1000

(c) and (f) (see NOTES 1, 2).................................. 1000

(d) and (e) (see NOTE 2)...................................... 1000

(d) and (f) (see NOTE 2)...................................... 1000

(e) and (f) (see NOTE 2)...................................... 1000

------------------------------------------------------------------------

\1\ Value to which test voltage is gradually increased.

Notes to Table 68.304(a):

(1) Gradually increase the voltage from zero to the values

listed in Table 68.304(a) over a 30-second time period, then

maintain the voltage for one minute. The current in the mesh formed

by the voltage source and these points shall not exceed 10 mA peak

at any time during this 90-second interval.

(2) Equipment states necessary for compliance with the

requirements of this section that cannot be achieved by normal means

of power shall be achieved artificially by appropriate means.

(3) A telephone connection, auxiliary lead, or E&M lead that has

an intentional dc conducting path to earth ground at operational

voltages (such as a ground start lead), may be excluded from the

leakage current test in that operational state. Leads or connections

excluded for this reason shall comply with the requirements of

Sec. 68.306(e)(1).

(4) A telephone connection, auxiliary lead, or E&M lead that has

an intentional dc conducting path to earth ground for protection

purposes at the leakage current test voltage (such as through a

surge suppressor), may have the component providing the conducting

path removed from the equipment for the leakage current test in that

operational state. Components removed for this reason shall comply

with the requirements of Sec. 68.306(e)(2).

(5) Filter paths, such as capacitors used in EMI filters, are

left in place during leakage current testing, since these components

can be a path for excessive leakage.

(6) For multi-unit equipment interconnected by cables, that is

evaluated and registered as an interconnected combination or

assembly, the specified 10 mA peak maximum leakage current

limitation other than between power connection points and other

points, may be increased as described here to accommodate cable

capacitance. The leakage current limitation may be increased to

(10N+0.13L) mA peak where L is the length of interconnecting cable

in the leakage path in meters and N is the number of equipment units

that the combination or assembly will place in parallel across a

telephone connection.

(7) RF filters and surge protectors on the line side of power

supplies may be disconnected before making Sec. 68.304 leakage

measurements. As an alternative to disconnecting these filters and

surge protectors, this measurement may be made using a dc voltage

equal to the peak ac test voltage.

9. Section 68.306 is revised to read as follows:

Sec. 68.306 Hazardous voltage limitations.

(a) General. Under no condition of failure of registered terminal

equipment or registered protective circuitry that can be conceived to

occur in the handling, operation or repair of such equipment or

circuitry, shall the open circuit voltage on telephone connections

exceed 70 volts peak after one second, except for voltages for network

control signalling, alerting and supervision.

(1) Type I E&M Leads. Registered terminal equipment shall comply

with the following requirements for terminal equipment on the ``A'' or

``B'' side of the interface as shown in Figures 68.3(e)(i):

(i) The dc current on the E lead shall not exceed 100 mA.

(ii) The maximum dc potentials to ground shall not exceed the

following when measured across a resistor of 20 kohms 10%:

Table 68.306(a).--Type I E&M, DC Potentials

------------------------------------------------------------------------

E lead M lead

------------------------------------------------------------------------

TE on ``B'' side originates 5 V..... 5 V.

signals to network on E

lead.

TE on ``A'' side originates -56.5 V; no positive -56.5 V; no positive

signals to network on M potential with potential with

lead. respect to ground. respect to ground.

------------------------------------------------------------------------

(iii) The maximum ac potential between E&M leads and ground

reference shall not exceed 5V peak.

(iv) M lead protection shall be provided so that voltages to ground

do not exceed 60 volts. For relay contact implementation, a power

dissipation capability of 0.5 watt shall be provided in the shunt path.

[[Page 61668]]

(v) If the registered terminal equipment contains an inductive

component in the E lead, it must assure that the transient voltage

across the contact as a result of a relay contact opening does not

exceed the following voltage and duration limitations:

(A) 300 volts peak,

(B) A rate of change of one volt per microsecond, and

(C) A 60-volt level after 20 milliseconds.

(2) Type II E&M Leads. Registered terminal equipment shall comply

with the following requirements:

(i) For terminal equipment on the ``A'' side of the interface, the

dc current in the E lead shall not exceed 100 mA. The maximum ac

potential between the E lead and ground shall not exceed 5 V peak.

(ii) For terminal equipment on the ``B'' side of the interface, the

dc current in the SB lead shall not exceed 100 mA. The maximum ac

potential between the SB lead and ground shall not exceed 5 V peak.

(iii) The maximum dc potentials to ground shall not exceed the

following when measured across a resistor of 20 kohms 10%:

Table 68.306(b).--Type II E&M, DC Potentials

----------------------------------------------------------------------------------------------------------------

E lead M lead SB lead SG lead

----------------------------------------------------------------------------------------------------------------

TE on ``B'' side of the 5 V....... 5 V -56.5 V; no positive 5

interface originates signals potential with V.

to network on E lead. respect to ground.

TE on ``A'' side of the -56.5 V; no positive 5 V 5 V...... 5

interface originates signals potential with V.

to network on M lead. respect to ground.

----------------------------------------------------------------------------------------------------------------

(iv) The maximum ac potential to ground shall not exceed 5V peak on

the following leads, from sources in the terminal equipment:

(A) M, SG and SB leads for terminal equipment on the ``A'' side of

the interface.

(B) E, SG and M leads for terminal equipment on the ``B'' side of

the interface.

(v) If the registered terminal equipment contains an inductive

component in the (E) or (M) lead, it must assure that the transient

voltage across the contact as a result of a relay contact opening does

not exceed the following voltage and duration limitations:

(A) 300 volts peak,

(B) A rate of change of one volt per microsecond, and

(C) A 60-volt level after 20 milliseconds.

(3) Off premises station voltages. (i) Talking battery or voltages

applied by the PBX (or similar systems) to all classes of OPS interface

leads for supervisory purposes must be negative with respect to ground,

shall not be more than -56.5 volts dc with respect to ground, and shall

not have a significant ac component.\1\

---------------------------------------------------------------------------

\1\ The ac component should not exceed 5 volts peak, when not

otherwise controlled by Sec. 68.308.

---------------------------------------------------------------------------

(ii) Ringing signals applied by the PBX (or similar systems) to all

classes of OPS interface leads shall comply with requirements in

paragraph (d) of this section. Ringing voltages shall be applied

between the ring conductor and ground.

(4) Direct Inward Dialing (DID). Voltages applied by the PBX (or

similar systems) to DID interface leads for supervisory purposes must

be negative with respect to ground, shall not be more than -56.5 volts

dc with respect to ground, and shall not have a significant ac

component.\2\

---------------------------------------------------------------------------

\2\ The ac component shall not exceed 5 volts peak, where not

otherwise controlled by Sec. 68.308.

---------------------------------------------------------------------------

(5) Local Area Data Channel Interfaces. For Local Area Data Channel

interfaces, during normal operating modes including terminal equipment

initiated maintenance signals, registered terminal equipment shall

ensure, except during the application of ringing (limitations specified

in paragraph (d) of this section), with respect to telephone

connections (tip, ring, tip 1, ring 1) that:

(i) Under normal operating conditions, the rms current per

conductor between short-circuit conductors, including dc and ac

components, does not exceed 350 milliamperes. For other than normal

operating conditions, the rms current between any conductor and ground

or between short-circuited conductors, including dc and ac components,

may exceed 350 milliamperes for no more than 1.5 minutes;

(ii) The dc voltage between any conductor and ground does not

exceed 60 volts. Under normal operating conditions it shall not be

positive with respect to ground (though positive voltages up to 60

volts may be allowed during brief maintenance states);

(iii) AC voltages are less than 42.4 volts peak between any

conductor and ground, (terminal equipment shall comply while other

interface leads are both):

(A) Unterminated, and

(B) Individually terminated to ground); and,

(iv) Combined ac and dc voltages between any conductor and ground

are less than 42.4 volt peak when the absolute value of the dc

component is less than 21.2 volts, and less than (32.8 + 0.454 x Vdc)

when the absolute value of the dc component is between 21.2 and 60

volts.

(6) Ringdown Voiceband Private Line and Voiceband Metallic Channel

Interface. During normal operation, registered terminal equipment for

connection to ringdown voiceband private line interfaces or voiceband

metallic channel interfaces shall ensure that:

(i) Ringing voltage does not exceed the voltage and current limits

specified in paragraph (d) of this section, and is:

(A) Applied to the ring conductor with the tip conductor grounded

for 2-wire interfaces, or

(B) Simplexed on the tip and ring conductors with ground simplexed

on the tip 1 and ring 1 conductors for 4-wire interfaces.

(ii) Except during the signaling mode or for monitoring voltage,

there is no significant positive dc voltage (not over +5 volts) with

respect to ground:

(A) For 2-wire ports between the tip lead and ground and the ring

lead and ground and

(B) For 4-wire ports between the tip lead and ground, the ring lead

and ground, the tip 1 lead and ground, and the ring 1 lead and ground.

(iii) The dc current per lead, under short circuit conditions shall

not exceed 140 milliamperes.

(b) Connection of non-registered equipment to registered terminal

equipment or registered protective circuitry.--General. Leads to, or

any elements having a conducting path to

[[Page 61669]]

telephone connections, auxiliary leads or E&M leads shall:

(1) Be reasonably physically separated and restrained from and be

neither routed in the same cable as nor use the same connector as leads

or metallic paths connecting power connections;

(2) Be reasonably physically separated and restrained from and be

neither routed in the same cable as nor use adjacent pins on the same

connector as metallic paths to lead to nonregistered equipment, when

specification details provided to the Commission, pursuant to,

Sec. 68.200(g), do not show that interface voltages are less than non-

hazardous voltage source limits in paragraph (c) of this section.

(c) Non-Hazardous Voltage Source. A voltage source is considered a

non-hazardous voltage source if it conforms with the requirements of

Sec. 68.302, Sec. 68.304 and paragraph (b) of this section, with all

connections to the source other than primary power connections treated

as ``telephone connections,'' and if such source supplies voltages no

greater than the following under all modes of operation and of failure:

(1) AC voltages less than 42.4 volts peak;

(2) DC voltages less than 60 volts; and

(3) Combined ac and dc voltages less than 42.4 volts peak when the

absolute value of the dc component is less than 21.2 volts and less

than (32.8 + 0.454 x V dc) when the absolute value of the dc

component is between 21.2 and 60 volts.

(d) Ringing Sources. Except for class A OPS interfaces, ringing

sources shall meet all of the following restrictions:

(1) Ringing Signal Frequency. The ringing signal shall use only

frequencies whose fundamental component is equal to or below 70 Hz.

(2) Ringing Signal Voltage. The ringing voltage shall be less than

300 V peak-to-peak and less than 200 V peak-to-ground across a

resistive termination of at least 1 megohm.

(3) Ringing Signal Interruption Rate. The ringing voltage shall be

interrupted to create quiet intervals of at least one second

(continuous) duration each separated by no more than 5 seconds. During

the quiet intervals, the voltage to ground shall not exceed the voltage

limits given in paragraph (a)(3)(i) of this section.

(4) Ringing Signal Sources. Ringing voltage sources shall comply

with the following requirements:

(i) If the ringing current through a 500 ohm(s) (and greater)

resistor does not exceed 100 mA peak-to-peak, neither a ring trip

device nor a monitoring voltage are required.

(ii) If the ringing current through a 1500 ohm (and greater)

resistor exceeds 100 mA peak-to-peak, the ringing source shall include

a current-sensitive ring trip device in series with the ring lead that

will trip ringing as specified in Figure 68.306(a) in accordance with

the following conditions:

(A) If the ring trip device operates as specified in Figure

68.306(a) with R=500 ohm (and greater) no monitoring voltage is

required;

(B) If, however, the ring trip device only operates as specified in

Figure 68.306(a) with R=1500 ohm (and greater) then the ringing voltage

source shall also provide a monitoring voltage between 19 V dc and 56.5

V dc, negative with respect to ground, on the tip or ring conductor.

(iii) If the ringing current through a 500-ohm (and greater)

resistor exceeds 100 mA (peak-to-peak) but does not exceed 100 mA peak-

to-peak with 1500-ohm (and greater) termination, the ringing voltage

source shall include either a ring trip device that meets the operating

characteristics specified in Figure 68.306(a) with 500-ohm (and

greater) resistor, or a monitoring voltage as specified in paragraph

(d)(4)(ii)(B) of this section.

Note to paragraph (d)(4)(iii): If the operating characteristics

specified in Figure 68.306(a) are not met with both the 500-ohm and

1500-ohm terminations, then the terminal equipment under test fails

(See Table 68.306(c)).

BILLING CODE 6712-01-P

[[Page 61670]]

[GRAPHIC] [TIFF OMITTED] TR19NO97.010

BILLING CODE 6712-01-C

[[Page 61671]]

Table 68.306(C).--Summary of Ring Trip Requirements

--------------------------------------------------------------------------------------------------------------------------------------------------------

Ringing current (mA p.p) Function required

-------------------------------------------------------------------------------------- Ring trip device operates

Section 68.306 (d)(4). R=500 ohms R=1500 ohms per figure 68.306(a)

and greater and greater Ring trip Monitor voltage

--------------------------------------------------------------------------------------------------------------------------------------------------------

(i)................................. 100 Yes......................... Optional.................... Yes for both resistances.

(ii)(B)............................. N/A >100 Yes......................... Yes......................... Yes for R=1500 ohms and

greater.

No for R=500 ohms and

greater.

(iii)............................... >100 150 Hz, the maximum power delivered to a 600 ohm

termination shall not exceed -8 dBm during the signaling mode. The

maximum power delivered to a 600 ohm termination in the on-hook steady

state supervisory condition shall not exceed -20 dBm. The maximum power

of other than live voice signals delivered to a 600 ohm termination

during the non-signaling mode and for other inband systems shall not

exceed -13 dBm when averaged over any 3-second interval.

(2) Limitations on internal signal sources primarily intended for

network control signaling, contained in voice and data equipment.

(i) For all operating conditions of registered terminal equipment

and registered protective circuitry, the maximum power in the frequency

band below 3995 Hz delivered to a loop simulator circuit shall not

exceed the following when averaged over any 3-second interval:

(A) 0 dBm when used for network control (DTMF);

(B) 0 dBm when DTMF is used for manual entry end-to-end signaling.

When the device is used for this purpose it shall not generate more

than 40 DTMF digits per manual key stroke.

(C) -9 dBm in all other cases.

(ii) For tie trunk applications, the maximum power delivered to a

600 ohm termination for registered terminal equipment and registered

protective circuitry under all operating conditions shall not exceed -4

dBm over any 3 second interval.

(3) Registered one port and multiport terminal equipment and

protective circuitry with provision for through transmission from other

terminal equipment, excluding data equipment and data protective

circuitry that are registered in accordance with Sec. 68.308(b)(4).

[[Page 61672]]

(i) Where through-transmission equipment provides a dc electrical

signal to equipment connected therewith (e.g., for powering of electro-

acoustic transducers), dc conditions shall be provided which fall

within the range of conditions provided by a loop simulator circuit

unless the combination of the through-transmission equipment and

equipment connected therewith is registered as a combination which

conforms to paragraphs (b)(1) and (b)(2) of this section.

(ii) Through-transmission equipment to which remotely connected

data terminal equipment may be connected shall not be equipped with or

connected to either a Universal or Programmed Data Jack used in data

configurations. (See paragraph (b)(4) of this section and

Sec. 68.502(e)).

(4) Registered data circuit terminal equipment shall be capable of

operation in at least one of the states discussed in paragraphs

(b)(1)(i), (b)(1)(ii) or (b)(1)(iii) of this section. The output power

level of the data circuit terminal equipment shall not be alterable, by

the customer, to levels which exceed the signal power limits specified

herein.

(i) Data circuit terminal equipment intended to operate with a

programming resistor for signal level control shall not exceed the

programmed levels given in Table 68.308(a).

(ii) Data circuit terminal equipment intended to operate in the

fixed loss loop (FLL) state shall not transmit signal power that

exceeds -4 dBm, in the 200--3995 Hz voiceband, when averaged over any

and all 3 second intervals.

(iii) Data circuit terminal equipment shall not transmit signals

from 200 to 3995 Hz that exceed -9 dBm, when averaged over any and all

3 second intervals.

Table 68.308(a)

------------------------------------------------------------------------

Programmed data equipment

Programming resistor (Rp)* (ohms) signal power output

------------------------------------------------------------------------

Short...................................... 0 dBm.

150........................................ -1 dBm.

336........................................ -2 dBm.

569........................................ -3 dBm.

866........................................ -4 dBm.

1240....................................... -5 dBm.

1780....................................... -6 dBm.

2520....................................... -7 dBm.

3610....................................... -8 dBm.

5490....................................... -9 dBm.

------------------------------------------------------------------------

*Tolerance ) 1%.

(5) Registered one-port and multiport terminal equipment and

protective circuitry with provision for through-transmission from ports

to other equipment which is separately registered for the public

switched network, or ports to other network interfaces.

(i) Registered terminal equipment and registered protective

circuitry shall have no adjustments that will allow net amplification

to occur in either direction of transmission in the through-

transmission path within the 200-3995 Hz voiceband that will exceed the

following:

Table 68.308(b).--Allowable Net Amplification Between Ports (A)(C)(D)(E)

--------------------------------------------------------------------------------------------------------------------------------------------------------

To Tie trunk type ports

------------------------------------------------------------------------------------- Public switched

Subrate 1.544 Integrated OPS ports (2- network ports HCC digital PBX-

From (E) \2/4\-wire Mbps satellite Subrate 1.544 services trunk wire) (B) (2-wire) CO 4-wire

4W Mbps tandem 4W

--------------------------------------------------------------------------------------------------------------------------------------------------------

\2/4\-Wire Tie................. 0 dB 3 dB 3 dB 3 dB 6 dB

Subrate 1.544 Mbps Satellite 4W 0 dB 3 dB 3 dB 6 dB

Tie.

Subrate 1.544 Mbps Tandem 4W -3 dB 0 dB 0 dB 0 dB 3 dB

Tie.

Integrated Services Trunk...... -3 dB 0 dB 0 dB 0 dB 3 dB

RTE Digital.................... 0 dB 0 dB 0 dB 0 dB 3 dB 3 dB 0 dB.

RTE (B) PSTN/OPS............... -3 dB -3 dB -3 dB -3 dB 0 dB 0 dB -3 dB

OPS (B) (2-Wire)............... -2 dB 1 dB 1 dB 1 dB 4 dB 4 dB 1 dB.

Public Switched Network (2- 3 dB 3 dB

Wire).

HCC Digital PBX-CO (4-Wire).... 3 dB

--------------------------------------------------------------------------------------------------------------------------------------------------------

(A) The source impedance for all measurements shall be 600 ohms.

All ports shall be terminated in appropriate loop or private line

channel simulator circuits or 600 ohm terminations.

(B) These ports are for 2-wire on-premises station ports to

separately registered terminal equipment.

(C) These through gain limitations are applicable to multiport

systems where channels are not derived by time or frequency compression

methods. Terminal equipment employing such compression techniques shall

assure that equivalent compensation for through gain parameters is

demonstrated in the registration application.

(D) Registered terminal equipment and registered protective

circuitry may have net amplification exceeding the limitations of this

subsection provided that, for each network interface type to be

connected, the absolute signal power levels specified in this section

are not exceeded.

(E) The indicated gain is in the direction that results when moving

from the horizontal entry toward the vertical entry.

(F) Registered terminal equipment or protective circuitry with the

capability for through transmission from voiceband private line

channels or voiceband metallic channels to other telephone network

interfaces shall ensure that the absolute signal power levels specified

in this section, for each telephone network interface type to be

connected, are not exceeded.

(G) Registered terminal equipment or protective circuitry with the

capability for through transmission from voiceband private line

channels or voiceband metallic private line channels to other telephone

network interfaces shall assure, for each telephone network interface

type to be connected, that signals with energy in the 2450 to 2750 Hz

band are not through transmitted unless there is at least an equal

amount of energy in the 800 to 2450 Hz band within 20 milliseconds of

application of signal.

[[Page 61673]]

(ii) The insertion loss in through connection paths for any

frequency in the 800 to 2450 Hz band shall not exceed the loss at any

frequency in the 2450 to 2750 Hz band by more than 1 dB (maximum loss

in the 800 to 2450 Hz band minus minimum loss in the 2450 to 2750 Hz

band plus 1 dB).

(6) For tie trunk interfaces--Limitation on idle circuit stability

parameters. For idle state operating conditions of registered terminal

equipment and registered protective circuitry, the following

limitations shall be met:

(i) For the two-wire interface:

[GRAPHIC] [TIFF OMITTED] TR19NO97.018

(ii) For the four-wire lossless interface:

[GRAPHIC] [TIFF OMITTED] TR19NO97.019

Note: The following definitions apply to return loss

requirements:

RL the return loss of 2-wire terminal equipment at the interface

with respect to 600 ohms+2.16 F (i.e., Zref=600

ohms+2.16 F).

[GRAPHIC] [TIFF OMITTED] TR19NO97.020

Rli the terminal equipment input (receive) port return

loss with respect to 600 ohms (i.e., Zref=600 ohms).

[GRAPHIC] [TIFF OMITTED] TR19NO97.021

RLo the terminal equipment output (transmit) port return

loss with respect to 600 ohms (i.e., Zref=600 ohms).

[GRAPHIC] [TIFF OMITTED] TR19NO97.022

tl the transducer loss between the receive and transmit ports of

the 4-wire PBX. tlf is the transducer loss in the forward

direction from the receive port to the transmit port of the PBX.

[GRAPHIC] [TIFF OMITTED] TR19NO97.023

Where Ii is the current sent into the receive port and

Ir is the current received at the transmit port

terminated at 600 ohms.

tlr is the transducer loss in the reverse direction, from

the transmit port to the receive port of the PBX.

[GRAPHIC] [TIFF OMITTED] TR19NO97.024

Where Ii is the current sent into the transmit port and

Ir is the current received at the receive port terminated

at 600 ohms. Note, the source impedance of Ii is 600

ohms.

(7) Registered terminal equipment and registered protective

circuitry shall provide the following range of dc conditions to off-

premises station (OPS) lines.

(i) DC voltages applied to the OPS interface for supervisory

purposes and during network control signaling shall meet the limits

specified in Sec. 68.306(a)(3)(i).

(ii) DC voltages applied to the OPS interface during the talking

state shall meet the following requirements:

(A) The maximum open circuit voltage across the tip (T(OPS)) and

ring (R(OPS)) leads for all classes shall not exceed 56.5 volts, and

(B) Except for class A OPS interfaces, the maximum dc current into

a short circuit across tip (T(OPS)) and ring (R(OPS)) leads shall not

exceed 140 mA.

(8) For connections to 1.544 Mbps digital services, the permissible

code words for unequipped Mu-255 encoded subrate channels are limited

to those corresponding to signals of either polarity, of magnitude

equal to or less than X48, where code word, XN is derived by:

XN = (255 - N) base 2

-XN = (127 - N) base 2

(c) Signal power in the 3995-4005 Hz frequency band.

(1) Power resulting from internal signal sources contained in

registered protective circuitry and registered terminal equipment

(voice and data), not intended for network control signaling. For all

operating conditions of registered terminal equipment and registered

protective circuitry that incorporate signal sources other than sources

intended for network control signaling, the maximum power delivered by

such sources in the 3995-4005 Hz band to an appropriate simulator

circuit, shall be 18 dB below maximum permitted power specified in

paragraph (b) of this section for the voiceband.

(2) Terminal equipment with provision of through-transmission from

other equipment. The loss in any through-transmission path of

registered terminal equipment and registered protective circuitry at

any frequency in the 600 to 4000 Hz band shall not exceed, by more than

3 dB, the loss at any frequency in the 3995 to 4005 Hz band, when

measured into an appropriate simulator circuit from a source that

appears as 600 ohms across tip and ring.

(d) Longitudinal voltage at frequencies below 4 kHz. The weighted

rms voltage \3\ averaged over 100 milliseconds that is resultant of all

of the component longitudinal voltages in the 100 Hz to 4 kHz band

after weighting according to the transfer

[[Page 61674]]

function of f/4000 where f is the frequency in Hertz, shall not exceed

the maximum indicated under the conditions stated in paragraph (g) of

this section.

---------------------------------------------------------------------------

\3\ Average magnitudes may be used for signals that have peak-

to-rms ratios of 20 dB and less. The rms limitations must be used

instead of average values if the peak-to-rms ratio of the

interfering signal exceeds this value.

------------------------------------------------------------------------

Maximum weighted

Frequency range rms voltage Impedance

------------------------------------------------------------------------

100 Hz to 4 kHz.................. -30 dBV 500 ohms.

------------------------------------------------------------------------

(e) Voltage in the 4 kHz to 6 MHZ frequency range-general case--2-

wire and 4-wire lossless interface (except LADC). Except as noted, rms

voltage as averaged over 100 milliseconds at the telephone connections

of registered terminal equipment and registered protective circuitry in

all of the possible 8 kHz bands within the indicated frequency range

and under the conditions specified in paragraph (g) of this section

shall not exceed the maximum indicated below. For paragraphs(e)(1) and

(e)(2)(i) of this section, ``f'' is the center frequency in kHz of each

of the possible 8-kHz bands beginning at 8 kHz.

(1) Metallic Voltage. 4 kHz to 270 kHz:

------------------------------------------------------------------------

Metallic

Center frequency (f) of 8 kHz Max voltage in all 8 terminating

band kHz bands impedance

------------------------------------------------------------------------

8 kHz to 12 khz................ -(6.4 + 12.6 log f) 300 ohms.

dBV.

12 kHz to 90 kHz............... ...................... 135 ohms.

90 kHz to 266 kHz.............. (23-40 log f) dBV -55. 135 ohms.

------------------------------------------------------------------------

(2) Longitudinal voltage.

(i) 4 kHz to 270 kHz.

(ii) 270 kHz to 6 MHZ. The rms value of the longitudinal voltage

components in the frequency range of 270 kHz to 6 MHZ, shall not exceed

-30 dBV. This limitation applies with a longitudinal termination having

an impedance of 90 ohms.

------------------------------------------------------------------------

Longitudinal

Center frequency (f) of 8 kHz Max voltage in all 8 terminating

band kHz bands impedance

------------------------------------------------------------------------

8 kHz to 12 kHz................ -(18.4 + 20 log f) dBV 500 ohms

12 kHz to 42 kHz............... ...................... 90 ohms

42 kHz to 266 kHz (2-40 log f) ...................... 90 ohms

dBV -62 dBV.

------------------------------------------------------------------------

(f) LADC interface. The metallic voltage shall comply with the

general requirements in paragraph (f)(1) of this section as well as the

additional requirements specified in paragraphs (f)(2) and (f)(3) of

this section. The requirements apply under the conditions specified in

paragraph (g) of this section. Terminal equipment for which the

magnitude of the source and/or terminating impedance exceeds 300 ohms,

at any frequency in the range of 100 kHz to 6 MHz, at which the signal

(transmitted and/or received) has significant power, shall be deemed

not to comply with these requirements. A signal is considered to have

``significant power'' at a given frequency if that frequency is

contained in a designated set of frequency bands that collectively have

the property that the rms voltage of the signal components in those

bands is at least 90% of the rms voltage of the total signal. The

designated set of frequency bands must be used in testing all

frequencies.

(1) Metallic voltages--frequencies below 4 kHz.

(i) Weighted rms voltage in the 10 Hz to 4 kHz frequency band. The

weighted rms metallic voltage in the frequency band from 10 Hz to 4

kHz, averaged over 100 milliseconds that is the resultant of all the

component metallic voltages in the band after weighting according to

the transfer function of f/4000 where f is the frequency in Hertz,

shall not exceed the maximum indicated below under the conditions

stated in paragraph (g) of this section.

------------------------------------------------------------------------

Frequency range Maximum voltage

------------------------------------------------------------------------

10 Hz to 4 kHz............................ +3 dBV.

------------------------------------------------------------------------

(ii) RMS Voltage in 100 Hz bands in the frequency range 0.7 kHz to

4 kHz. The rms metallic voltage averaged over 100 milliseconds in the

100-Hz bands having center frequencies between 750 Hz and 3950 Hz shall

not exceed the maximum indicated below.

------------------------------------------------------------------------

Max voltage in all 100-Hz

Center freq (f) of 100-Hz bands bands

------------------------------------------------------------------------

750 to 3950 Hz............................. -6 dBV.

------------------------------------------------------------------------

(2) Metallic Voltages--frequencies above 4 kHz--LADC interface.

(i) 100-Hz bands over frequency range of 4 kHz to 270 kHz. The rms

voltage as averaged over 100 milliseconds in all possible 100-Hz bands

between 4 kHz and 270 kHz for the indicated range of center frequencies

and under the conditions specified in paragraph (g) of this section

shall not exceed the maximum indicated below:

------------------------------------------------------------------------

Max voltage in all 100-Hz

Center freq (f) of all 100-Hz bands bands

------------------------------------------------------------------------

4.05 kHz to 4.6 kHz........................ 0.5 dBV.

4.60 kHz to 5.45 kHz....................... (59.2--90 log f) dBV.

5.45 kHz to 59.12 kHz..................... (7.6--20 log f) dBV.

59.12 kHz to 266.00 kHz.................... (43.1--40 log f) dBV.

------------------------------------------------------------------------

Where f = center frequency in kHz of each of the possible 100 Hz

bands.

(ii) 8-kHz bands over frequency range of 4 kHz to 270 kHz. The rms

voltage as averaged over 100 milliseconds in all of the possible 8-kHz

bands between 4 kHz and 270 kHz for the indicated range of center

frequencies and under the conditions specified in paragraph (g) of this

section shall not exceed the maximum indicated below:

[[Page 61675]]

------------------------------------------------------------------------

Center freq (f) of 8-kHz bands Max voltage in all 8-kHz bands

------------------------------------------------------------------------

8 kHz to 120 kHz.................... (17.6--20 log f) dBV.

120 kHz to 266 kHz.................. (59.2--40 log f) dBV.

------------------------------------------------------------------------

Where f = center frequency in kHz of each of the possible 8-kHz

bands.

(iii) RMS Voltage at frequencies above 270 kHz. The rms value of

the metallic voltage components in the frequency range of 270 kHz to 6

MHZ, averaged over 2 microseconds, shall not exceed -15 dBV. This

limitation applies with a metallic termination having an impedance of

135 ohms.

(iv) Peak Voltage. The total peak voltage for all frequency

components in the 4 kHz to 6 MHZ band shall not exceed 4.0 volts.

(3) Longitudinal voltage. Frequencies below 4kHz: The weighted rms

voltage in the frequency band from 10 Hz to 4 kHz,averaged over 100

milliseconds is the resultant of all the component longitudinal

voltages in the band after weighing according to the transfer function

of f/4000, where f is the frequency in Hz, shall not exceed the maximum

indicated below under the conditions stated in paragraph (g) of this

section.

(i) Frequencies below 4 kHz. The weighted rms voltage in the

frequency band from 10 Hz to 4 kHz,averaged over 100 milliseconds is

the resultant of all the component longitudinal voltages in the band

after weighing according to the transfer function of f/4000, where f is

the frequency in Hz, shall not exceed the maximum indicated below under

the conditions stated in paragraph (g) of this section.

------------------------------------------------------------------------

Frequency range Maximum RMS voltage

------------------------------------------------------------------------

10 Hz-4 kHz.............................. -37 dBV.

------------------------------------------------------------------------

(ii) 4 kHz to 270 kHz.

------------------------------------------------------------------------

Longitudinal

Ctr freq (f) of 8 kHz bands Max voltage in all 8 terminating

kHz bands impedance

------------------------------------------------------------------------

8 to 12 kHz.................... -(18.4+20 log f) dBV.. 500 ohms.

12 to 42 kHz................... (3-40 log f) dBV...... 90 ohms

42 to 266 kHz.................. -62 dBV............... 90 ohms.

------------------------------------------------------------------------

Where f = center frequency in kHz of each of the possible 8-kHz bands.

(iii) 270 kHz to 6 MHZ. The rms value of the longitudinal voltage

components in the frequency range of 270 kHz to 6 MHZ shall, averaged

over 2 microseconds, not exceed -30 dBV. This limitation applies with a

longitudinal termination having an impedance of 90 ohms.

(d) Longitudinal voltage at frequencies below 4 kHz. The weighted

rms voltage \4\ averaged over 100 milliseconds that is resultant of all

of the component longitudinal voltages in the 100 Hz to 4 kHz band

after weighting according to the transfer function of f/4000 where f is

the frequency in Hertz, shall not exceed the maximum indicated under

the conditions stated in Sec. 68.308(g).

\4\ Average magnitudes may be used for signals that have peak-

to-rms ratios of 20 dB and less. The rms limitations must be used

instead of average values if the peak-to-rms ratio of the

interfering signal exceeds this value.

------------------------------------------------------------------------

Maximum weighted rms

Frequency range voltage Impedance

------------------------------------------------------------------------

100 Hz to 4 kHz................ -30 dBV............... 500 ohms.

------------------------------------------------------------------------

(e) Voltage in the 4 kHz to 6 MHZ frequency range--general case--2-

wire and 4-wire lossless interface (except LADC). Except as noted, rms

voltage as averaged over 100 milliseconds at the telephone connections

of registered terminal equipment and registered protective circuitry in

all of the possible 8 kHz bands within the indicated frequency range

and under the conditions specified in paragraph (g) of this section

shall not exceed the maximum indicated below. For paragraph (e)(1) and

paragraph (e)(2)(i) of this section, ``f'' is the center frequency in

kHz of each of the possible 8-kHz bands beginning at 8 kHz.

(1) Metallic Voltage. 4 kHz to 270 kHz:

------------------------------------------------------------------------

Metallic

Center frequency (f) of 8 kHz Max voltage in all 8 terminating

band kHz bands impedance

------------------------------------------------------------------------

8 kHz to 12 kHz................ -(6.4 + 12.6 log f) 300 ohms.

dBV.

12 kHz to 90 kHz............... (23-40 log f) dBV..... 135 ohms.

90 kHz to 266 kHz.............. -55 dBV............... 135 ohms.

------------------------------------------------------------------------

(2) Longitudinal voltage

(i) 4 kHz to 270 kHz.

(ii) 270 kHz to 6 MHZ. The rms value of the longitudinal voltage

components in the frequency range of 270 kHz to 6 MHZ, shall not exceed

-30 dBV. This limitation applies with a longitudinal termination having

an impedance of 90 ohms.

------------------------------------------------------------------------

Longitudinal

Center frequency (f) of 8kHz Max voltage in all 8 terminating

band kHz bands impedance

------------------------------------------------------------------------

8 kHz to 12 kHz................ -(18.4 + 20 log f) dBV 500 ohms.

12 kHz to 42 kHz............... (2-40 log f) dBV...... 90 ohms.

[[Page 61676]]

42 kHz to 266 kHz.............. -62 dBV............... 90 ohms.

------------------------------------------------------------------------

(f) LADC interface. The metallic voltage shall comply with the

general requirements in paragraph (f)(1) of this section as well as the

additional requirements specified in paragraphs (f)(2) and (3) of this

section as stated. The requirements apply under the conditions

specified in Sec. 68.308(g). Terminal equipment for which the magnitude

of the source and/or terminating impedance exceeds 300 Ohms, at any

frequency in the range of 100 kHz to 6 MHz, at which the signal

(transmitted and/or received) has significant power, shall be deemed

not to comply with these requirements. A signal is considered to have

``significant power'' at a given frequency if that frequency is

contained in a designated set of frequency bands that collectively have

the property that the rms voltage of the signal components in those

bands is at least 90% of the rms voltage of the total signal. The

designated set of frequency bands must be used in testing all

frequencies.

(1) Metallic voltages--frequencies below 4 kHz.

(i) Weighted rms voltage in the 10 Hz to 4 kHz frequency band. The

weighted rms metallic voltage in the frequency band from 10 Hz to 4

kHz, averaged over 100 milliseconds that is the resultant of all the

component metallic voltages in the band after weighting according to

the transfer function of f/4000 where f is the frequency in Hertz,

shall not exceed the maximum indicated below under the conditions

stated in paragraph (g).

------------------------------------------------------------------------

Frequency range Maximum voltage

------------------------------------------------------------------------

10 Hz to 4 kHz............................. +3 dBV.

------------------------------------------------------------------------

(ii) RMS Voltage in 100 Hz bands in the frequency range 0.7 kHz to

4 kHz. The rms metallic voltage averaged over 100 milliseconds in the

100-Hz bands having center frequencies between 750 Hz and 3950 Hz shall

not exceed the maximum indicated below.

------------------------------------------------------------------------

Max voltage in all 100-Hz

Center freq (f) of 100-Hz bands bands

------------------------------------------------------------------------

750 to 3950 Hz............................. -6 dBV.

------------------------------------------------------------------------

(2) Metallic Voltages--frequencies above 4 kHz--LADC interface.

(i) 100-Hz bands over frequency range of 4 kHz to 270 kHz. The rms

voltage as averaged over 100 milliseconds in all possible 100-Hz bands

between 4 kHz and 270 kHz for the indicated range of center frequencies

and under the conditions specified in Sec. 68.308(g) shall not exceed

the maximum indicated below:

------------------------------------------------------------------------

Center freq (f) of all 100-Hz bands Max voltage in all 100-Hz bands

------------------------------------------------------------------------

4,05 kHz to 4.6 kHz................ 0.5 dBV.

4.60 kHz to 5.45 kHz............... (59.2-90 log f) dBV.

5.45 kHz to 59.12 kHz.............. (7.6-20 log f) dBV.

59.12 kHz to 266.00 kHz............ (43.1-40 log f) dBV.

------------------------------------------------------------------------

Where f = center frequency in kHz of each of the possible 100 Hz bands.

(ii) 8-kHz bands over frequency range of 4 kHz to 270 kHz. The rms

voltage as averaged over 100 milliseconds in all of the possible 8-kHz

bands between 4 kHz and 270 kHz for the indicated range of center

frequencies and under the conditions specified in Sec. 68.308(g) shall

not exceed the maximum indicated below:

------------------------------------------------------------------------

Center freq (f) of 8-kHz bands Max voltage in all 8-kHz bands

------------------------------------------------------------------------

8 kHz to 120 kHz................... (17.6-20 log f) dBV.

120 kHz to 266 kHz................. (59.2-40 log f) dBV.

------------------------------------------------------------------------

Where f = center frequency in kHz of each of the possible 8-kHz bands.

(iii) RMS Voltage at frequencies above 270 kHz. The rms value of

the metallic voltage components in the frequency range of 270 kHz to 6

MHZ, averaged over 2 microseconds, shall not exceed -15 dBV. This

limitation applies with a metallic termination having an impedance of

135 ohms.

(iv) Peak Voltage. The total peak voltage for all frequency

components in the 4 kHz to 6 MHZ band shall not exceed 4.0 volts.

(3) Longitudinal voltage.

(i) Frequencies below 4kHz. The weighted rms voltage in the

frequency band from 10 Hz to 4kHz, averaged over 100 milliseconds is

the resultant of all the component longitudinal voltages in the band

after weighing according to the transfer function of f/4000, where f is

the frequency in Hz, shall not exceed the maximum indicated below under

the conditions stated in Sec. 68.308(g).

------------------------------------------------------------------------

Frequency range Maximum RMS voltage

------------------------------------------------------------------------

10 Hz-4 kHz...................................... -37 dBV.

------------------------------------------------------------------------

(ii) 4 kHz to 270 kHz

[[Page 61677]]

------------------------------------------------------------------------

Longitudinal

Center freq (f) of 8-kHz bands Max voltage in all 8- terminating

kHz bands Voltage

------------------------------------------------------------------------

8 kHz to 12 kHz................ -(18.4 + 20 log f) dBV 500 ohms.

12 kHz to 42 kHz............... (3-20 log f) dBV...... 90 ohms.

42 kHz to 266 kHz.............. -62 dBV............... 90 ohms

------------------------------------------------------------------------

Where f = center frequency in kHz of each of the possible 8-kHz bands.

(iii) 270 kHz to 6 MHZ. The rms value of the longitudinal voltage

components in the frequency range of 270 kHz to 6 MHZ shall, averaged

over 2 microseconds, not exceed -30 dBV. This limitation applies with a

longitudinal termination having an impedance of 90 ohms.

BILLING CODE 6712-01-P

[[Page 61678]]

[GRAPHIC] [TIFF OMITTED] TR19NO97.011

BILLING CODE 6712-01-C

[[Page 61679]]

(g) Requirements in paragraphs (d), (e) and (f) of this section

apply under the following conditions: (1) All registered terminal

equipment, except equipment to be used on LADC, and all registered

protective circuitry must comply with the limitations when connected to

a termination equivalent to the circuit depicted in Figure 68.308(a)

and when placed in all operating states of the equipment except during

network control signaling. LADC registered terminal equipment must

comply with the metallic voltage limitations when connected to circuits

of Sec. 68.3(i) and must comply with the longitudinal limitations when

connected to circuits of Figure 68.308(a), as indicated.

(2) All registered terminal equipment and registered protective

circuitry must comply with the limitations in the off-hook state over

the range of loop currents that would flow with the equipment connected

to an appropriate simulator circuit.

(3) Registered terminal equipment and registered protective

circuitry with provision for through-transmission from other equipments

shall comply with the limitations with a 1000 Hz tone applied from a

600-ohm source (or, if appropriate a source which reflects a 600-ohm

impedance across tip and ring) at the maximum level that would be

applied during normal operation. Registered protective circuitry for

data shall also comply with the tone level 10 dB higher than the

overload point.

(4) For registered terminal equipment or registered protective

circuitry with non-registered signal source input, such as music on

hold, the out of band signal power requirements shall be met using an

input signal with a frequency range of 200 Hz to 20 kHz and the level

set at the overload point.

(5) Except during the transmission of ringing (Sec. 68.306(d)) and

Dual Tone Multi-frequency (DTMF) signals, LADC registered terminal

equipment shall comply with all requirements in all operating states

and with loop current that may be drawn for such purposes as loop back

signaling. The requirements in paragraph (f)(1) of this section except

in paragraphs (f)(1)(i) and (f)(1)(ii) of this section also apply

during the application of ringing. The requirement in paragraph (d) and

the requirements in paragraphs (f)(1)(i) and (f)(1)(ii) of this section

apply during ringing for frequencies above 300 Hz and with the maximum

voltage limits raised by 10 dB. DTMF signals which are used for the

transmission of alphanumeric information and which comply with the

requirements in paragraph (f)(1)(i) and in paragraphs (f)(2) or (f)(3)

of this section as applicable, shall be deemed to comply with the

requirements in paragraph (f)(1)(ii) of this section provided that, for

automatically originated DTMF signals, the duty cycle is less than 50

percent.

(6) LADC registered terminal equipment shall comply with all

applicable requirements, except those specified in paragraphs (f)(1)

(i) and (ii) of this section, during the transmission of each possible

data signal sequence of any length. For compliance with paragraph

(f)(3)(i) of this section, the limitation applies to the rms voltage

averaged as follows:

(i) For digital signals, baseband or modulated on a carrier, for

which there are defined signal element intervals, the rms voltage is

averaged over each such interval. Where multiple carriers are involved,

the voltage is the power sum of the rms voltages for the signal element

intervals for each carrier.

(ii) For baseband analog signals, the rms voltage is averaged over

each period (cycle) of the highest frequency of the signal (3 dB point

on the spectrum). For analog signals that are modulated on a carrier

(whether or not the carrier is suppressed), it is averaged over each

period (cycle) of the carrier. Where multiple carriers are involved,

the voltage is the power sum of the rms voltage for each carrier.

(iii) For signals other than the types defined in paragraphs

(g)(6)(i) and (ii) of this section, the peak amplitude of the signal

must not exceed +1 dBV.

(7) Equipment shall comply with the requirements in paragraphs

(f)(1)(i) and (ii) of this section, during any data sequence that may

be transmitted during normal use with a probability greater than 0.001.

If the sequences transmitted by the equipment are application

dependent, the user instruction material shall include a statement of

any limitations assumed in demonstrating compliance of the equipment.

(8) In addition to the conditions specified in paragraph (g)(5) of

this section, LADC registered terminal equipment which operates in one

or more modes as a receiver, shall comply with requirements in

paragraph (f)(3) of this section with a tone at all frequencies in the

range of potential received signals and at the maximum power which may

be received.

(h) Interference limitations for transmission of bipolar signals

over digital services.--(1) Limitations on Terminal Equipment

Connection to Subrate Digital Services--(i) Pulse repetition rate. The

pulse repetition rate shall be synchronous with 2.4, 3.2, 4.8, 6.4,

9.6, 12.8, 19.2, 25.6, 38.4, 56.0, or 72 kbps per second.

(ii) Template for maximum output pulse. When applied to a 135 Ohm

resistor, the instantaneous amplitude of the largest isolated output

pulse obtainable from the registered terminal equipment shall not

exceed by more than 10% the instantaneous voltage defined by a template

obtained as follows: The limiting pulse template shall be determined by

passing an ideal 50% duty cycle rectangular pulse with the amplitude/

pulse rate characteristics defined in Table 68.308(c) through a single

real pole low pass filter having a cutoff frequency in Hertz equal to

1.3 times the bit rate. For bit rates of 2.4, 3.2, 4.8, 6.4, 9.6 and

12.8 kbps, the filtered pulses shall also be passed through a filter

providing the additional attenuation in Table 68.308(d).

Table 68.308(c).--Driving Pulse Amplitude

------------------------------------------------------------------------

Amplitude

Line rate (kbps) User data rate (R) (kbps) (A)

(volts)

------------------------------------------------------------------------

2.4............................... 2.4...................... 1.66

3.2............................... 2.4 with SC \1\.......... 1.66

4.8............................... 4.8...................... 1.66

6.4............................... 4.8 with SC \1\.......... 1.66

9.6............................... 9.6...................... 0.83

12.8.............................. 9.6 with SC \1\.......... 0.83

19.2.............................. 19.2..................... 1.66

25.6.............................. 19.2 with SC \1\......... 1.66

38.4.............................. 38.4..................... 1.66

51.2.............................. 38.4 with SC \1\......... 1.66

56................................ 56....................... 1.66

72................................ 56 with SC \1\........... 1.66

72................................ 64....................... 1.66

------------------------------------------------------------------------

\1\ SC: Secondary Channel.

Table 68.308(d).--Minimum Additional Attenuation

------------------------------------------------------------------------

Attenuation Attenuation

in in

Line rate (R) (kbps) frequency frequency

band 24-32 band 72-80

kHz (dB) kHz (dB)

------------------------------------------------------------------------

2.4........................................... 5 1

3.2........................................... 5 1

4.8........................................... 13 9

6.4........................................... 13 9

9.6........................................... 17 8

12.8.......................................... 17 8

------------------------------------------------------------------------

Note: The attenuation indicated may be reduced at any frequency within

the band by the weighting curve of Table 68.308(e). Minimum rejection

is never less than 0 dB; i.e., the weight does not justify gain over

the system without added attenuation.

Table 68.308(e).--Attenuation Curve

------------------------------------------------------------------------

72-80 kHz Attenuation

24-32 kHz band band factor dB

------------------------------------------------------------------------

24.............................................. 72 -18

[[Page 61680]]

25.............................................. 73 -3

26.............................................. 74 -1

27.............................................. 75 0

29.............................................. 76 0

29.............................................. 77 0

30.............................................. 78 -1

31.............................................. 79 -3

32.............................................. 80 -18

------------------------------------------------------------------------

(iii) Average power. The average output power when a random signal

sequence, (0) or (1) equiprobable in each pulse interval, is being

produced as measured across a 135 ohm resistance shall not exceed 0 dBm

for 9.6 and 12.8 kbps or +6 dBm for all other rates shown in Table

68.308(b).

(iv) Encoded analog content. If registered terminal equipment

connecting to subrate services contains an analog-to-digital converter,

or generates signals directly in digital form that are intended for

eventual conversion into voiceband analog signals, the encoded analog

content of the digital signal must be limited. The maximum equivalent

power of encoded analog signals for other than live voice as derived by

a zero level decoder test configuration shall not exceed -12 dBm when

averaged over any 3-second time interval. The maximum equivalent power

of encoded analog signals as derived by a zero level decoder test

configuration for signals intended for network control signaling shall

not exceed -3 dBm when averaged over any 3-second interval.

(2) Limitations on Terminal Equipment Connecting to 1.544 Mbps

Digital Services.--(i) Pulse repetition rate: The free running line

rate of the transmit signal shall be 1.544 Mbps with a tolerance of

32 ppm., i.e., 50 bps.

(ii) Output pulse templates. The registered terminal equipment

shall be capable of optionally delivering three sizes of output pulses.

The output pulse option shall be selectable at the time of

installation.

(A) Option A output pulse. When applied to a 100 ohm resistor, the

instantaneous amplitude of the largest output pulse obtainable from the

registered terminal equipment shall fall within the pulse template

illustrated in Figure 68.308b). The mask may be positioned horizontally

as needed to encompass the pulse, and the amplitude of the normalized

mask may be uniformity scaled to encompass the pulse. The baseline of

the mask shall coincide with the pulse baseline.

(B) Option B output pulse. When applied to a 100-ohm resistor, the

instantaneous amplitude of the output from the registered terminal

equipment obtained when Option B is implemented shall fall within the

pulse template obtained by passing the bounding pulses permitted by

Figure 68.308(b) through the following transfer function.

[GRAPHIC] [TIFF OMITTED] TR19NO97.025

where:

n0=1.6049 x 106

n1=7.9861 x 10-1

n2=9.2404 x 10-8

d0=2.1612 x 106

d1=1.7223

d2=4.575 x 10-7

d3=3.8307 x 10-14

S=j 2 f

f=frequency (Hertz)

(C) Option C output pulse. When applied to a 100-ohm resistor, the

instantaneous amplitude of the output from the registered terminal

equipment obtained when Option C is implemented shall fall within the

pulse template obtained by passing the pulses obtained in Option B

through the transfer function in Option B a second time.

BILLING CODE 6712-01-P

[[Page 61681]]

[GRAPHIC] [TIFF OMITTED] TR19NO97.012

BILLING CODE 6712-01-C

Maximum Curve

--------------------------------------------------------------------------------------------------------------------------------------------------------

Nano-seconds -500 -250 -175 -175 -75 0 175 220 500 750

--------------------------------------------------------------------------------------------------------------------------------------------------------

Normalized Amplitude.......................................... .05 .05 .8 1.2 1.2 1.05 1.05 -.05 .05 .05

--------------------------------------------------------------------------------------------------------------------------------------------------------

Minimum Curve

--------------------------------------------------------------------------------------------------------------------------------------------------------

Nano-seconds -500 -150 -150 -100 0 100 150 150 300 396 600 750

--------------------------------------------------------------------------------------------------------------------------------------------------------

Normalized Amplitude........................ -.05 -.05 .5 .9 .95 .9 .5 -.45 -.45 -.26 -.05 -.05

--------------------------------------------------------------------------------------------------------------------------------------------------------

Figure 68.308(b) (Ref. EIA/TIA 547-1989)--Isolated Pulse Template

and Corner Points for 1.544 Mbps Equipment

Note to Figure 68.308(b): The pulse amplitude is 2.4 to 3.6 V.

(Use constant scaling factor to fit normalized template.)

(iii) Adjustment of signal voltage. The signal voltage at the

network interface must be limited so that the range of pulse amplitudes

received at the first telephone company repeater is controlled to

4 dB. This limitation is achieved by implementing the

appropriate output pulse option as a function of telephone company

cable loss as specified at time of installation.

------------------------------------------------------------------------

Terminal equipment

---------------------------------

Cable loss at 772 kHz (dBV) Loss at

Output pulse 772 kHz

------------------------------------------------------------------------

15 to 22.............................. Option A.............. 0

7.5 to 15............................. Option B.............. 7.5

0 to 7.5.............................. Option C.............. 15

------------------------------------------------------------------------

(iv) Output power. The output power in a 3 kHz band about 772 kHz

when an all ones signal sequence is being produced as measured across a

100 ohm terminating resistance shall not exceed +19 dBm. The power in a

3 kHz band about 1.544 MHz shall be at least 25 dB below that in a 3

kHz band about 772 kHz.

(v) Encoded Analog Content. If registered terminal equipment

connected to 1.544 Mbps digital service contains an analog-to-digital

converter, or generates signals directly in digital form that are

intended for eventual conversion into voiceband analog signals, the

encoded analog content of the subrate channels within the 1.544 Mbps

signal must be limited. The maximum equivalent power of encoded analog

signals for other than live voice that are not intended for network

[[Page 61682]]

control signaling as derived by a zero level decoder test configuration

shall not exceed -12 dBm when averaged over any 3-second time interval.

The maximum equivalent power of encoded analog signals as derived by a

zero level decoder test configuration for signals intended for network

control signaling shall not exceed -3 dBm when averaged over any 3-

second interval.

11. Section 68.310 is revised to read as follows:

Sec. 68.310 Transverse balance limitations.

(a) Technical description and application. The Transverse

Balancem-1, coefficient is expressed as

[GRAPHIC] [TIFF OMITTED] TR19NO97.026

(1) Where eL is the longitudinal voltage produced across

a longitudinal termination Z1 and eM is the

metallic voltage across the tip-ring or tip 1 and ring 1 interface of

the input port when a voltage (at any frequency between f1

and 2, see Table 68.310(a) is applied from a balanced

source with a metallic impedance Z0 (see Table 68.310(a).

The source voltage should be set such that eM = E volts (see

Table 68.310(a) when a termination of Z0 is substituted for

the terminal equipment.

(2) The minimum transverse balance coefficient specified in this

section (as appropriate) shall be equalled or exceeded for all 2-wire

network ports, OPS line ports and the transmit pair (tip and ring) and

receive pair (tip 1 and ring 1) of all 4-wire network ports at all

values of dc loop current that the port under test is capable of

drawing when attached to the appropriate loop simulator circuit (See

Sec. 68.3). An illustrative test circuit that satisfies the above

conditions is shown in Figure 68.310-1(a) for analog and 68.310-1(b)

for digital and subrate; other means may be used to determine the

transverse balance coefficient specified herein, provided that adequate

documentation of the appropriateness, precision, and accuracy of the

alternative means is provided by the applicant.

(3) The minimum transverse balance requirements specified below

shall be equalled or exceeded under all reasonable conditions of the

application of earth ground to the equipment or protective circuitry

under test.

Table 68.310(a)

----------------------------------------------------------------------------------------------------------------

Analog voiceband Subrate digital 1.544 Mbps digital

----------------------------------------------------------------------------------------------------------------

Longitudinal Termination--Zl.... 500 ohms................ See Table 310(b)............... 90 ohms.

Metallic Source Impedance--Z0... 600 ohms................ 135 ohms....................... 100 ohms.

Lower Frequency--f1............. 200 Hz.................. 200 Hz......................... 10 kHz.

Upper Frequency--f2............. 4 kHz................... (\1\) 1.544 MHz.

Metallic Voltage for Test--E.... 0.775 V................. 0.367 V........................ 0.316 V.

----------------------------------------------------------------------------------------------------------------

\1\ The upper frequency equals the digital line rate for the subrate service under test (See Table 68.310(b)).

(b) Analog voiceband equipment. All registered analog voiceband

equipment shall be tested in the off-hook state. The minimum transverse

balance requirement in the off-hook state shall be 40 dB, throughout

the range of frequencies specified in Table 68.310(a). For some

categories of equipment, additional requirements also apply to the on-

hook state. When both off-hook and on-hook requirements apply, they

are:

------------------------------------------------------------------------

State Frequency (f) Balance

------------------------------------------------------------------------

Off-hook...................... 200 Hz : f : 4000 Hz....... 40 dB.

On-hook....................... 200 Hz : f : 1000 Hz....... 60 dB.

On-hook....................... 1000 Hz : f : 4000 Hz...... 40 dB.

------------------------------------------------------------------------

(1) For analog one-port 2-wire terminal equipment with loop-start,

ringdown, or inband signaling or for voiceband metallic channel

applications, both off-hook and on-hook requirements apply.

(2) For analog one port equipment with ground-start and reverse-

battery signaling only off-hook requirements apply.

(3) For analog registered protective circuitry for 2-wire

applications with loop-start, ringdown, or inband signaling; or for

voiceband metallic channel applications, both off-hook and on-hook

requirements apply. Criteria shall be met with either terminal of the

interface to other equipment connected to earth ground. The interface

to other equipment shall be terminated in an impedance that will be

reflected to the telephone connection as 600 Ohms in the off-hook state

of the registered protective circuit, and the interface should not be

terminated in the on-hook state. Figure 68.310(b) shows the interface

of the protective circuitry being tested and the required arrangement

at the interface to other equipment.

(4) For analog registered protective circuitry with ground-start

and reverse-battery signaling only off-hook requirements apply.

Criteria shall be met with either terminal of the interface to other

equipment connected to earth ground. The interface to other equipment

shall be terminated in an impedance that will be reflected to the

telephone connection as 600 ohms in the off-hook state of the

registered protective circuit. Figure 68.310(b) shows the interface of

the protective circuitry under test and the required arrangement at the

interface to the other equipment.

(5) For analog multi-port equipment with loop-start signaling both

off-hook and on-hook requirements apply. Criteria shall be satisfied

for all ports when all the ports not under test are terminated in their

appropriate networks, as will be identified below, and when interface

connections other than the ports are terminated in circuits appropriate

to that interface. The minimum transverse balance coefficients shall

also be satisfied for all values of dc loop current that the registered

equipment is capable of drawing through each of its ports when these

ports are attached to the loop simulator circuit specified in these

rules. The termination for all ports other than the particular one

whose transverse balance coefficient is being measured shall have a

metallic impedance of 600 ohms.

(6) For analog multi-port equipment with ground-start and reverse-

battery signaling, only off-hook requirements apply. Criteria shall be

satisfied for all ports when all ports not under test are terminated in

their appropriate networks as will be identified below, and when

interface connections other than the ports are terminated in circuits

appropriate to that interface. The minimum transverse balance

coefficients shall be satisfied for all values of dc loop current that

the registered equipment is capable of drawing through each of its

ports when these ports are attached to the loop simulator circuit

specified in these rules. The terminations for all ports

[[Page 61683]]

other than the particular one whose transverse balance coefficient is

being measured shall have a metallic impedance of 600 ohms and a

longitudinal impedance of 500 ohms. Figure 68.310(c) shows this

termination.

(7) For analog registered terminal equipment and protective

circuitry for 4-wire network ports, both the off-hook and on-hook

requirements apply. The pair not under test shall be terminated in a

metallic impedance of 600 ohms. Other conditions are as follows:

(i) For analog registered protective circuitry with loop-start,

ground-start, reverse battery, ringdown, or inband signaling; or for

voiceband metallic channel applications. Criteria shall be met with

either terminal of the interface to other equipment connected to earth

ground. The interface to other equipment shall be terminated in an

impedance that will result in 600 ohms at each of the transmit and

receive pairs of the 4-wire telephone connection in the off-hook state

of the registered protective circuit, and the interface should not be

terminated in the on-hook state. Figure 68.310(d) shows the interface

of the protective circuitry being tested and the required arrangement

at the interface to other equipment.

(ii) For analog multiport equipment with loop start, ground start,

and reverse battery, ringdown, or inband signaling; or for voiceband

metallic channel applications. Criteria shall be satisfied for all

network ports when all the ports not under test are terminated as

defined below, and when interface connections other than the network

ports are terminated in circuits appropriate to the interface. The

criteria shall also be satisfied for all values of dc loop current that

when the port is connected to the appropriate 4-wire loop simulator

circuit. The terminations for both pairs of all network ports not under

test shall have a metallic impedance of 600 ohms and a longitudinal

impedance of 500 ohms. Figure 68.310(c) shows this termination.

(8) For analog PBX equipment (or similar systems) with class B or

class C off-premises interfaces, only off-hook requirements apply.

Criteria shall be satisfied for all off-premises station interface

ports when these ports are terminated in their appropriate networks for

their off-hook state, and when all other interface connections are

terminated in circuits appropriate to that interface. The minimum

transverse balance coefficients shall also be satisfied for all values

of dc loop current that the registered PBX is capable of providing

through off-premises station ports when these ports are attached to the

off-premises line simulator circuit specified in these rules.

(9) For Type Z equipment with loop-start signaling, both off-hook

and on-hook requirements apply. Equipment that has on-hook impedance

characteristics which that do not conform to the requirements of

Sec. 68.312 (e.g., Type Z), shall comply with minimum transverse

balance requirements of 40 dB in the voiceband. See Sec. 68.312(h) for

conditions upon registration of ``Type Z'' equipment.

(c) Digital equipment. The minimum transverse balance requirements

for registered terminal equipment connected to digital services shall

be equalled or exceeded for the range of frequencies applicable for the

equipment under test and under all reasonable conditions of the

application of earth ground to the equipment. All such terminal

equipment shall have a transverse balance in the acceptable region of

Figure 68.310(e) for the range of frequencies shown in Table 68.310(b)

for the specified digital service in question. The metallic impedance

used for the transverse balance measurements for all subrate services

shall be 135 ohms and for 1.544 Mbps shall be 100 ohms. The

longitudinal termination for 1.544 Mbps and subrate services shall be

as defined in Table 68.310(b).

Frequency Ranges of Transverse Balance Requirements for Digital Services

----------------------------------------------------------------------------------------------------------------

Longitudinal Metallic

Digital service Frequency range termination termination

(ohms) (ohms)

----------------------------------------------------------------------------------------------------------------

2.4........................................... 200 to 2.4 kHz....................... 500 135

3.2........................................... 200 to 3.2 kHz....................... 500 135

4.8........................................... 200 to 4.8 kHz....................... 500 135

6.4........................................... 200 to 6.4 kHz....................... 500 135

9.6........................................... 200 to 9.6 kHz....................... 500 135

12.8\1\....................................... 200 to 12.8 kHz...................... 500/90 135

19.2\1\....................................... 200 to 19.2 kHz...................... 500/90 135

25.6\1\....................................... 200 to 25.6 kHz...................... 500/90 135

38.4\1\....................................... 200 to 38.4 kHz...................... 500/90 135

56\1\......................................... 200 to 56 kHz........................ 500/90 135

72\1\......................................... 200 to 72 kHz........................ 500/90 135

1.544......................................... 10 kHz to 1.544 MHz.................. 90 100

----------------------------------------------------------------------------------------------------------------

\1\ For 200 to 12 kHz the longitudinal termination shall be 500 ohms and above 12 kHz the longitudinal

termination shall be 90 ohms.

BILLING CODE 6712-01-P

[[Page 61684]]

[GRAPHIC] [TIFF OMITTED] TR19NO97.013

[[Page 61685]]

[GRAPHIC] [TIFF OMITTED] TR19NO97.014

[[Page 61686]]

[GRAPHIC] [TIFF OMITTED] TR19NO97.015

[[Page 61687]]

[GRAPHIC] [TIFF OMITTED] TR19NO97.016

[[Page 61688]]

[GRAPHIC] [TIFF OMITTED] TR19NO97.017

BILLING CODE 6712-01-C

[[Page 61689]]

12. Section 68.312 is revised to read as follows:

Sec. 68.312 On-hook impedance limitations.

(a) General. Requirements in this section apply to the tip and ring

conductors of 2-wire interfaces. These requirements also apply to 4-

wire loop-start or ground-start interfaces, in the following

configuration:

(1) The tip and ring conductors are connected together and treated

as one of the conductors of a tip and ring pair.

(2) The tip 1 and ring 1 conductors are connected together and

treated as the other conductor of a tip and ring pair.

Note to Sec. 68.312: Throughout this section, references will be

made to simulated ringing. Ringing voltages to be used and impedance

limitations associated with simulated ringing are shown in Table

68.312(a).

Table 68.312(a)

----------------------------------------------------------------------------------------------------------------

Impedance

Ringing type Range of compatible ringing Simulated ringing voltage limitations

frequencies (Hz) superimposed on 56.5 volts dc (ohms)

----------------------------------------------------------------------------------------------------------------

A.................................... 203.............. 40 to 130 volts rms.......... 1400

303.............. 40 to 130 volts rms.......... 1000

B.................................... 15.3 to 34................... 40 to 130 volts rms.......... 1600

>34 to 49.................... 62 to 130 volts rms.......... 1600

>49 to 68.................... 62 to 150 volts rms.......... 1600

----------------------------------------------------------------------------------------------------------------

(b) Limitations on individual equipment intended for operation on

loop-start telephone facilities. Registered terminal equipment and

registered protective circuitry shall conform to the following

limitations:

(1) On-hook resistance, metallic and longitudinal (up to 100 Vdc).

The on-hook dc resistance between the tip and ring conductors of a loop

start interface, and between each of the tip and ring conductors and

earth ground, shall be greater than 5 megohms for all dc voltages up to

and including 100 volts.

(2) On-hook resistance, metallic and longitudinal (100 V to 200

Vdc). The on-hook dc resistance between tip and ring conductors of a

loop start interface, and between each of the tip and ring conductors

and earth ground shall be greater than 30 kOhms for all dc voltages

between 100 and 200 volts.

(3) DC current during ringing. During the application of simulated

ringing, as listed in Table 68.312(a), to a loop start interface, the

total dc current shall not exceed 3.0 milliamperes. The equipment must

comply for each ringing type which is listed as part of the ringer

equivalence.

(4) Ringing frequency impedance (metallic). During the application

of simulated ringing, as listed in Table 68.312(a), to a loop start

interface, the impedance between the tip and ring conductors (defined

as the quotient of applied ac voltage divided by resulting true rms

current) shall be greater than or equal to the value specified in Table

68.312(a). The equipment must comply for each ringing type which is

listed as part of the ringer equivalence.

(5) Ringing Frequency Impedance (longitudinal). During the

application of simulated ringing, as listed in Table 68.312(a), to a

loop start interface, the impedance between each of the tip and ring

conductors and ground shall be greater than 100 kohms. The equipment

must comply with each ringing type listed in the ringer equivalence.

(c) Limitations on individual equipment intended for operation on

ground start telephone facilities. Registered terminal equipment and

registered protective circuitry shall conform to the following

limitations:

(1) DC current during ringing. During the application of simulated

ringing, as listed in Table 68.312(a), to a ground start interface, the

total dc current flowing between tip and ring conductors shall not

exceed 3.0 milliamperes. The equipment must comply for each ringing

type listed as part of the ringer equivalence.

(2) Ringing frequency impedance (metallic). During the application

of simulated ringing, as listed in Table 68.312(a), to a ground start

interface, the total impedance of the parallel combination of the ac

impedance across tip and ring conductors and the ac impedance from the

ring conductor to ground (with ground on the tip conductor) shall be

greater than the value specified in Table 68.312(a). The equipment must

comply for each ringing type listed as part of the ringer equivalence.

(d) Ringer Equivalence Definition. The ringer equivalence number is

defined to be the value determined in paragraphs (d)(1) or (d)(2) of

this section, as appropriate, followed by the ringer type letter

indicator representing the frequency range for which the number is

valid. If Ringer Equivalence is to be stated for more than one Ringing

Type, testing shall be performed at each frequency range to which

Ringer Equivalence is to be determined in accordance with the above,

and the largest resulting Ringer Equivalence Number so determined will

be associated with each Ringing Type letter designation for which it is

valid.

(1) For individual equipment intended for operation on loop-start

telephone facilities, the ringer equivalence is five times the

impedance limitation listed in Table 68.312(a), divided by the minimum

measured ac impedance, as defined in paragraph (b)(1)(iv) of this

section, during the application of simulated ringing as listed in Table

68.312(a).

(2) For individual equipment intended for operation on ground-start

telephone facilities, the ringer equivalence is five times the

impedance limitation listed in Table 68.312(a), divided by the minimum

measured ac impedance, defined in paragraph (c)(2) of this section,

during the application of simulated ringing as listed in Table

68.312(a).

(e) Ringer equivalence number labeling. Registered terminal

equipment and registered protective circuitry shall have at least one

Ringer Equivalence Number shown on the registration label. Where

options that will vary the Ringer Equivalence are involved, either each

option that results in a Ringer Equivalence Number greater than 0.1 and

its corresponding Ringer Equivalence shall be listed on the

registration label, or the largest Ringer Equivalence Number that can

result from such options shall be stated on the label. A trained,

authorized agent of the Grantee may disconnect ringers, bridge ringers

to another line, or execute options affecting Ringer Equivalence after

the telephone company has been notified in accordance with Sec. 68.106.

(f) Maximum ringer equivalence. All registered terminal equipment

and registered protective circuitry that can affect the ringing

frequency impedance shall be assigned a Ringer Equivalence. The sum of

all such Ringer Equivalences

[[Page 61690]]

on a given telephone line or loop shall not exceed 5. In some cases, a

system that has a total Ringer Equivalence of 5 or less may not be

usable on a given telephone line or loop.

(g) OPS interfaces for PBX with DID (Ring trip requirement). PBX

ringing supplies whose output appears on the off-premises interface

leads shall not trip when connected to the following tip-to-ring

impedance that terminates the off-premises station loop: A terminating

impedance composed of the parallel combination of a 15 kohms resistor

and an RC series circuit (resistor and capacitor) whose ac impedance is

as specified in Table 68.312(b) below.

Table 68.312(b)

------------------------------------------------------------------------

ac impedance ohms

-------------------------

Ringing freq Hz Class B or

C Class A

------------------------------------------------------------------------

20 3............................. 7000/N 1400

30 3............................. 5000/N 1000

------------------------------------------------------------------------

N--Number of ringer equivalences, as specified by the manufacturer,

which can be connected to the off-premises station loop.

(h) Type Z Ringers. Equipment that has on-hook impedance

characteristics which do not conform to the requirements of this

section may be conditionally registered, notwithstanding the

requirements of this section, provided that it is labeled with a

Ringing Type designation ``Z''. It should be noted that registration of

equipment bearing the designation ``Z'' does not necessarily confer any

right of connection to the telephone network under these rules. Any

equipment registered with the type Z designation may only be used with

the consent of the local telephone company, provided that the local

telephone company does not discriminate in its treatment of equipment

bearing the type Z designation.

(i) Transitioning to the Off-Hook State. Registered terminal

equipment and registered protective circuitry shall not by design leave

the on-hook state by operations performed on tip and ring leads for any

other purpose than to request service or answer an incoming call,

except that terminal equipment that the user places in the off-hook

state for the purpose of manually placing telephone numbers in internal

memory for subsequent automatic or repertory dialing shall be

registerable. Make-busy indications shall be transmitted by the use of

make-busy leads only as defined in Sec. 68.3 and Sec. 68.200(j).

13. Section 68.314 is revised to read as follows:

Sec. 68.314 Billing protection.

(a) Call duration requirements on data equipment connected to the

public switched network, or to tie trunks, or to private lines that

access the public switched network. Registered data terminal equipment

and registered protective circuitry shall comply with the following

requirements when answering an incoming call, except in off-hook states

in which the signals are transmitted and/or received by electroacoustic

transducers only.

Note to paragraph (a) of this section: This paragraph is

applicable to terminal equipment and registered protective circuitry

employed with digital services where such digital services are

interconnected with the analog telephone network.

(1) Registered protective circuitry. Registered protective

circuitry connected to associated data equipment shall assure that the

following signal power limitations are met for at least the first 2

seconds after the off-hook condition is presented to the telephone

network in response to an incoming call:

(i) Signals that appear at the protective circuitry/telephone

network interface for delivery to the telephone network shall be

limited to -55 dBm, (at any frequency in the range of 200 to 3200

Hertz), as such signals are delivered into a loop simulator circuit or

a 600 ohm termination, as appropriate; and

(ii) Signals that appear at the protective circuitry-associated

data equipment interface for delivery to associated data equipment

shall be limited as follows: for any received signal power (appearing

at the protective circuitry-telephone network interface) up to 0 dB

with respect to one milliwatt (at any frequency in the range of 200 to

3200 Hertz), the power of signals delivered to associated data

equipment shall be no greater than the signal power that would be

delivered as a result of received signal power of -55 dBm.

(2) Registered terminal equipment. Registered terminal equipment

for data applications shall assure that, when an incoming telephone

call is answered, the answering terminal equipment prevents both

transmission and reception of data for at least the first two seconds

after the answering terminal equipment transfers to the off-hook

condition. For the purpose of this requirement, a fixed sequence of

signals that is transmitted (and originated within) and/or received by

the registered terminal equipment each time it answers an incoming call

shall not be considered data, provided that such signals are for one or

more of the following purposes:

(i) Disabling echo control devices,

(ii) Adjusting automatic equalizers and gain controls,

(iii) Establishing synchronization, or

(iv) Signaling the presence and if required, the mode of operation,

of the data terminal at the remote end of a connection.

(b) Voice and data equipment on-hook signal requirements for

equipment connected to the public switched network, or to tie trunks,

or to private lines that access the public switched network. Registered

protective circuitry and registered terminal equipment shall comply

with the following:

(1) The power delivered into a 2-wire loop simulator circuit or

into the transmit and receive pairs of a 4-wire loop simulator or into

a 600 ohm termination (where appropriate) in the on-hook state, by

loop-start or ground-start equipment shall not exceed -55 dBm within

the voiceband. Registered protective circuitry shall also assure that

for any input level up to 10 dB above the overload point, the power to

a 2-wire loop simulator circuit or the transmit and receive pairs of a

4-wire loop simulator circuit or into a 600 ohm termination (where

appropriate) does not exceed the above limits.

(2) The power delivered into a 2-wire loop simulator circuit or

into the transmit and receive pairs of a 4-wire loop simulator circuit,

in the on-hook state, by reverse battery equipment shall not exceed -55

dBm, unless the equipment is arranged to inhibit incoming signals.

(c) Voice and data equipment loop current requirements for

equipment connected to the public switched network. The loop current

through registered terminal equipment or registered protective

circuitry, when connected to a 2-wire or 4-wire loop simulator circuit

with the 600 ohm resistor and 500 microfarad capacitor of the 2-wire

loop simulator circuit or both pairs of the 4-wire loop simulator

circuit disconnected shall, for at least 5 seconds after the equipment

goes to the off-hook state that would occur when answering an incoming

call:

(1) Be at least as great as the current obtained in the same loop

simulator circuit with minimum battery voltage and a maximum loop

resistance when a 200 ohm resistance is connected across the tip and

ring of the 2-wire loop simulator circuit or connected across the tip/

ring and tip 1/ring 1 conductors (tip and ring connected together and

tip 1 and ring 1 connected together) of the 4-wire loop simulator

circuit in place of

[[Page 61691]]

the registered terminal equipment or registered protective circuitry;

or

(2) Not decreased by more than 25 percent from its maximum value

attained during this 5-second interval; unless the equipment is

returned to the on-hook state during the above 5 second interval.

(3) The above requirements also apply in the hold state and any

off-hook state.

(d) Signaling interference requirements. (1) The signal power

delivered to the network interface by the registered terminal equipment

and from signal sources internal to registered protective circuitry in

the 2450 Hz to 2750 Hz band shall be less than or equal to the power

present simultaneously in the 800 Hz to 2450 Hz band for the first 2

seconds after going to the off-hook state.

(2) Registered terminal equipment for connection to subrate or

1.544 Mbps digital services shall not deliver digital signals to the

telephone network with encoded analog content energy in the 2450 to

2750 Hertz band unless at least an equal amount of encoded analog

energy is present in the 800 to 2450 Hertz band for the first two

seconds after going to the off-hook state.

(e) On-hook requirements for registered terminal equipment for

connection to subrate and 1.544 Mbps digital services. Registered

terminal equipment and registered protective circuitry shall comply

with the following:

(1) The power delivered to the telephone network in the on-hook

state as derived by a zero level decoder shall not exceed -55 dBm

equivalent power for digital signals within the voiceband.

(2) Registered protective circuitry shall also assure that the

power to a zero level decoder does not exceed the above limits for any

input level up to 10 dB above the overload point.

(3) Reverse battery interface. The power derived by a zero level

decoder, in the on-hook state, by reverse battery equipment, shall not

exceed -55 dBm, unless the equipment is arranged to inhibit incoming

signals.

(f) Off hook requirements. Off-hook signal requirements for

registered terminal equipment connecting to 1.544 Mbps digital

services. Upon entering the normal off-hook state, in response to

alerting, for subrate channels, registered terminal equipment shall

continue to transmit the signaling bit sequence representing the off-

hook state for 5 seconds, unless the equipment is returned to the on-

hook state during the above 5-second interval.

(g) Operating requirements for direct inward dialing. (1) For

registered terminal equipment, the off-hook state shall be applied

within 0.5 seconds of the time that:

(i) The terminal equipment permits the acceptance of further digits

that may be used to route the incoming call to another destination.

(ii) The terminal equipment transmits signals towards the calling

party, except for the call progress tones, i.e., busy, reorder and

audible ring, and the call is:

(A) Answered by the called, or another station;

(B) Answered by the attendant;

(C) Routed to a customer controlled or defined recorded

announcement, except for ``number invalid,'' ``not in service'' or

``not assigned;''

(D) Routed to a dial prompt; or

(E) Routed back to the public switched telephone network or other

destination and the call is answered. If the status of the answered

call cannot be reliably determined by the terminal equipment through

means such as, detection of answer supervision or voice energy, removal

of audible ring, etc., the off-hook state shall be applied after an

interval of not more than 20 seconds from the time of such routing. The

off-hook state shall be maintained for the duration of the call.

(2) For registered protective circuitry:

(i) Registered protective circuitry shall block transmission

incoming from the network until an off-hook signal is received from the

terminal equipment.

(ii) Registered protective circuitry shall provide an off-hook

signal within 0.5s following the receipt of an off-hook signal from the

terminal equipment and shall maintain this off-hook signal for the

duration of the call.

14. Section 68.316 is amended by revising the section heading to

read as follows:

Sec. 68.316 Hearing aid compatibility: Technical requirements.

* * * * *

15. Section 68.317 is amended by revising the section heading to

read as follows:

Sec. 68.317 Hearing aid compatibility volume control: technical

standards.

* * * * *

16. Section 68.318 is revised to read as follows:

Sec. 68.318 Additional limitations.

(a) General. Registered terminal equipment for connection to those

services discussed below must incorporate the specified features.

(b) Registered terminal equipment with automatic dialing

capability. (1) Automatic dialing to any individual number is limited

to two successive attempts. Automatic dialing equipment which employ

means for detecting both busy and reorder signals shall be permitted an

additional 13 attempts if a busy or reorder signal is encountered on

each attempt. The dialer shall be unable to re-attempt a call to the

same number for at least 60 minutes following either the second or

fifteenth successive attempt, whichever applies, unless the dialer is

reactivated by either manual or external means. This rule does not

apply to manually activated dialers that dial a number once following

each activation.

Note to paragraph (b)(1): Emergency alarm dialers and dialers

under external computer control are exempt from these requirements.

(2) If means are employed for detecting both busy and reorder

signals, the automatic dialing equipment shall return to its on-hook

state within 15 seconds after detection of a busy or reorder signal.

(3) If the called party does not answer, the automatic dialer

shall return to the on-hook state within 60 seconds of completion of

dialing.

(4) If the called party answers, and the calling equipment does

not detect a compatible terminal equipment at the called end, then

the automatic dialing equipment shall be limited to one additional

call which is answered. The automatic dialing equipment shall comply

with paragraphs (b)(1), (b)(2), and (b)(3) of this section for

additional call attempts that are not answered.

(5) Sequential dialers shall dial only once to any individual

number before proceeding to dial another number.

(6) Network addressing signals shall be transmitted no earlier

than:

(i) 70 ms after receipt of dial tone at the network demarcation

point; or

(ii) 600 ms after automatically going off-hook (for single line

equipment that does not use dial tone detectors); or

(iii) 70 ms after receipt of CO ground start at the network

demarcation point.

(c) Line seizure by automatic telephone dialing systems. Automatic

telephone dialing systems which deliver a recorded message to the

called party must release the called party's telephone line within 5

seconds of the time notification is transmitted to the system that the

called party has hung up, to allow the called party's line to be used

to make or receive other calls.

(d) Telephone facsimile machines; Identification of the sender of

the message. It shall be unlawful for any person within the United

States to use a computer or other electronic device to send any message

via a telephone facsimile machine unless such message clearly contains,

in a margin at the top or bottom of each transmitted page or on the

first page of the transmission, the date and time it is sent and an

identification of the business, other entity, or individual sending the

[[Page 61692]]

message and the telephone numb

This text is long and has been trimmed here. Open the source document for the complete record.