National Primary Drinking Water Regulations: Interim Enhanced Surface Water Treatment Rule Notice of Data Availability

Federal RegisterNov 3, 1997

Ask Donna

What actually matters in this document.

Text

SUMMARY: USEPA proposed in 1994 to amend the Surface Water Treatment

Rule to provide additional protection against disease-causing organisms

(pathogens) in drinking water (59 FR 38832: July 29, 1994). This Notice

of Data Availability summarizes the 1994 proposal; describes new data

and information that the Agency has obtained and analyses that have

been developed since the proposal; provides information concerning

recommendations of the Microbial-Disinfectants/Disinfection Byproducts

(M-DBP) Advisory Committee (chartered in February 1997 under the

Federal Advisory Committee Act) on key issues related to the proposal;

and requests comment on these recommendations as well as on other

regulatory implications that flow from the new data and information.

USEPA solicits comment on all aspects of this Notice and the supporting

record. The Agency also solicits additional data and information that

may be relevant to the issues discussed in the Notice. USEPA is

particularly interested in public comment on the Committee's

recommendations and whether the Agency should reflect these

recommendations in the final rule. In addition, USEPA is hereby

providing notice that the Agency is re-opening the comment period for

the 1994 proposal for 90 days beginning on the date of publication of

today's Notice in the Federal Register. USEPA also requests that any

information, data or views submitted to the Agency since the close of

the comment period on the 1994 proposal that members of the public

would like the Agency to consider as part of the final rule development

process be resubmitted during this current 90-day comment period unless

already in the underlying record in the Docket for this Notice.

The Interim Enhanced Surface Water Treatment Rule (IESWTR) would

apply to surface water systems serving 10,000 or more people. USEPA

intends to promulgate the final rule in November 1998 as required by

the 1996 Amendments to the Safe Drinking Water Act. The Agency plans

subsequently to address surface water systems serving fewer than 10,000

people as part of a ``long-term'' Enhanced Surface Water Treatment Rule

which may also include additional refinements for larger systems.

Key issues related to the IESWTR that are addressed in this Notice

include the establishment of a Maximum Contaminant Level Goal for

Cryptosporidium; removal of Cryptosporidium by filtration; revised

turbidity provisions; disinfection benchmark provisions to assure

continued levels of microbial protection while facilities take the

necessary steps to comply with new disinfection byproduct standards;

sanitary surveys; inclusion of Cryptosporidium in the definition of

ground water under the direct influence of surface water; and inclusion

of Cryptosporidium in the watershed control requirements for unfiltered

public water systems. Other issues that are discussed include

inactivation of Cryptosporidium, viruses and Giardia lamblia; uncovered

finished water reservoirs; cross connection control; and recycling of

filter backwash water and filter-to-waste.

Today's Federal Register also contains a related Notice of Data

Availability for the Stage 1 Disinfectants/Disinfection Byproducts Rule

(DBPR). USEPA proposed this rule at the same time as the IESWTR and

plans to promulgate it along with the IESWTR in November 1998.

DATES: Comments should be postmarked or delivered by hand on or before

February 3, 1998. Comments must be received or post-marked by midnight

February 3, 1998.

ADDRESSES: Send written comments to IESWTR NODA Docket Clerk, Water

Docket (MC-4101); U.S. Environmental Protection Agency; 401 M Street,

SW; Washington, DC 20460. Please submit an original and three copies of

your comments and enclosures (including references). If you wish to

hand-deliver your comments, please call the Docket between 9:00 a.m.

and 4 p.m., Monday through Friday, excluding legal holidays, to obtain

the room number for the Docket. Comments may be submitted

electronically to [email protected].

FOR FURTHER INFORMATION, CONTACT: The Safe Drinking Water Hotline,

Telephone (800) 426-4791. The Safe Drinking Water Hotline is open

Monday through Friday, excluding Federal holidays, from 9:00 am to 5:30

pm Eastern Time. For technical inquiries, contact Elizabeth Corr or

Paul S. Berger, Ph.D.(Microbiology), Office of Ground Water and

Drinking Water (MC 4607), U.S. Environmental Protection Agency, 401 M

Street SW, Washington DC 20460; telephone (202) 260-8907 (Corr) or

(202) 260-3039 (Berger).

Regional Contacts

Region I. Kevin Reilly, Water Supply Section, JFK Federal Bldg., Room

203, Boston, MA 02203, (617) 565-3616

II. Michael Lowy, Water Supply Section, 290 Broadway, 24th Floor, New

York, NY 10007-1866, (212) 637-3830

III. Jason Gambatese, Drinking Water Section (3WM41), 841 Chestnut

Building, Philadelphia, PA 19107, (215) 566-5759

IV. David Parker, Water Supply Section, 345 Courtland Street, Atlanta,

GA 30365, (404)562-9460

V. Kimberly Harris (micro), Miguel Del Toral (DBP), Water Supply

Section, 77 W. Jackson Blvd., Chicago, IL 60604, (312) 886-4239

(Harris), (312) 886-5253 (Del Toral)

VI. Blake L. Atkins, Team Leader, Water Supply Section, 1445 Ross

Avenue, Dallas, TX 75202, (214) 665-2297

VII. Stan Calow, State Programs Section, 726 Minnesota Ave., Kansas

City, KS 66101, (913) 551-7410

VIII. Bob Clement, Public Water Supply Section (8WM-DW), 999 18th

Street, Suite 500, Denver, CO 80202-2466, (303) 312-6653

IX. Bruce Macler, Water Supply Section, 75 Hawthorne Street, San

Francisco, CA 94105, (415) 744-1884

X. Wendy Marshall, Drinking Water Unit, 1200 Sixth Avenue (OW-136),

Seattle, WA 98101, (206) 553-1890.

SUPPLEMENTARY INFORMATION:

Regulated entities. Entities potentially regulated by the IESWTR

are public water systems that use surface water and serve at least

10,000 people. Regulated categories and entities include:

------------------------------------------------------------------------

Category Examples of regulated entities

------------------------------------------------------------------------

Public Water System.................... PWSs that use surface water and

serve at least 10,000 people.

State Governments...................... State government offices that

regulate drinking water.

------------------------------------------------------------------------

[[Page 59487]]

This table is not intended to be exhaustive, but rather provides a

guide for readers regarding entities likely to be regulated by the

IESWTR. This table lists the types of entities that USEPA is now aware

could potentially be regulated by the rule. Other types of entities not

listed in this table could also be regulated. To determine whether your

facility may be regulated by this action, you should carefully examine

the applicability criteria outlined under Alternatives A and B in

Sec. 141.70 of the proposed rule (59 FR 38832, July 29, 1994).

If you have questions regarding the applicability of the IESWTR to

a particular entity, contact one of the persons listed in the preceding

FOR FURTHER INFORMATION CONTACT section.

Additional Information for Commenters. The Agency requests that

commenters follow the following format: type or print comments in ink,

and cite, where possible, the paragraph(s) in this Notice to which each

comment refers. Commenters should use a separate paragraph for each

method or issue discussed. Electronic comments must be submitted as a

WP5.1 or WP6.1 file or as an ASCII file avoiding the use of special

characters and any form of name or title of the Federal Register.

Comments and data will also be accepted on disks in WordPerfect in 5.1

or WP6.1 or ASCII file format. Electronic comments on this Notice may

be filed online at many Federal Depository Libraries. Commenters who

want EPA to acknowledge receipt of their comments should include a

self-addressed, stamped envelope. No facsimiles (faxes) will be

accepted.

Availability of Record. The record for this Notice, which includes

supporting documentation as well as printed, paper versions of

electronic comments, is available for inspection from 9 to 4 p.m.,

Monday through Friday, excluding legal holidays at the Water Docket,

U.S. EPA Headquarters, 401 M. St., S.W. Washington, D.C. 20460. For

access to docket materials, please call 202/260-3027 to schedule an

appointment and obtain the room number.

Copyright Permission. Supporting documentation reprinted in this

document from copyrighted material may be reproduced or republished

without restriction in accordance with 1 CFR 2.6.

List of Abbreviations Used in This Document

ASCE--American Society of Civil Engineers

ASTM--American Society for Testing Materials

AWWA--American Water Works Association

C--the residual concentration of disinfectant, mg/L

CDC--Centers for Disease Control

CFE--Combined Filter Effluent

CFR--Code of Federal Regulations

CPE--Comprehensive Performance Evaluation

CT--the residual concentration of disinfectant multiplied by the

contact time

DOC--dissolved organic carbon

ESWTR--Enhanced Surface Water Treatment Rule

FACA--Federal Advisory Committee Act

gpm/sf--gallons per minute per square foot

HAA5--Haloacetic acids (monochloroacetic, dichloroacetic,

trichloroacetic, monobromoacetic, and dibromoacetic acids)

HAV--hepatitis A virus

hrs--hours

ICR--Information Collection Rule

IESWTR--Interim Enhanced Surface Water Treatment Rule

IFA--Individual Filter Assessment

IFE--Individual Filter Effluent

ISO--International Standards Organization

k--the pseudo first-order reaction rate constant

L--liter

Log Inactivation--logarithm of (No/NT)

Log--logarithm (common, base 10)

LTESWTR--Long Term Enhanced Surface Water Treatment Rule

MCL--Maximum Contaminant Level

MCLG--Maximum Contaminant Level Goal

M-DBP--Microbial and Disinfectants/Disinfection Byproducts

mg/L--milligram per liter

mg-min/L--milligram minutes per liter

MMWR--Morbidity and Mortality Weekly Report

mW-s/cm2--milliwatt seconds per square centimeter

No--the initial viable concentration of microorganisms

NPDWR--National Primary Drinking Water Regulation

NT--the concentration of surviving microorganisms at time T

NTU--nephelometric turbidity unit

deg.C--degrees centigrade

PE--Performance Evaluation

pH--negative logarithm of the effective hydrogen-ion concentration

PV1--poliovirus 1

PV3--poliovirus 3

PWS--Public Water System

RSD--Relative Standard Deviation

SAB--Science Advisory Board

SDWA--Safe Drinking Water Act

T--the contact time, second or minute

TOC--total organic carbon

TTHM--Total Trihalomethanes

TWG--Technical Work Group

UV--ultraviolet

x--log removal Reduction by 1/10**x

Table of Contents

I. Introduction and Background

A. Existing regulations

1. Surface Water Treatment Rule

2. Total Trihalomethane MCL

3. Total Coliform Rule

4. Information Collection Rule

B. Public health concerns to be addressed

C. Statutory provisions

1. SDWA and 1986 provisions

2. Changes to initial provisions and new mandates

D. Regulatory negotiation process

E. Information Collection Rule

F. Formation of 1997 Federal Advisory Committee

G. Overview of 1994 proposed IESWTR

1. Summary of major elements

2. Alternative treatment requirements

3. Possible supplemental treatment requirements

a. uncovered finished water reservoirs

b. cross connection control program

c. State notification of high turbidity levels

4. Other related issues

II. New Information and Key Issues To Be Addressed

A. MCLG for Cryptosporidium

1. Summary of 1994 proposal and public comments

2. New data and perspectives

3. Advisory Committee recommendations and related issues

B. Removal of Cryptosporidium by filtration

1. Summary of 1994 proposal and public comments

2. New data and perspectives

a. rapid granular filtration

b. other filtration technologies

c. multiple barrier approach

3. Advisory Committee recommendations and related issues

C. Turbidity control

1. Summary of 1994 proposal as it relates to turbidity issues

and public comments

2. New data and perspectives

a. 95th percentile and maximum turbidity levels of composite

filtered water

b. individual filter performance

c. turbidity measurement

3. Advisory Committee recommendations and related issues

D. Disinfection benchmark for Stage I DBP MCLs

1. Applicability

2. Developing the profile and benchmark

3. State review

4. Guidance

5. Request for public comment

E. Definition of ground water under direct influence of surface

water (GWUDI)--inclusion of Cryptosporidium in the definition

1. Summary of 1994 proposal and public comments

2. Overview of existing guidance

3. Summary of new data and perspectives

[[Page 59488]]

4. Request for public comment

F. Inclusion of Cryptosporidium in watershed control requirements

1. Summary of 1994 proposal and public comments

2. Overview of existing guidance

3. Summary of new data and perspectives

G. Sanitary survey requirements

1. Summary of 1994 proposal

2. Overview of existing regulations and guidance

3. New developments

4. Advisory Committee recommendations and related issues

H. Covered finished water reservoirs

1. Summary of 1994 proposal and public comments

2. Overview of existing information

3. Request for public comment

I. Cross connection control program

1. Summary of 1994 proposal and public comments

2. Overview of existing information

3. Request for public comment

J. Recycling filter backwash water and filtering to waste

1. Filter backwash recycle configuration

2. State drinking water regulations

3. Literature overview of standards of practice

4. Filter-to-waste

5. Request for public comment

K. Certification criteria for water plant operators

L. Regulatory compliance schedule and other compliance-related

issues

1. Regulatory compliance schedule

2. Compliance violations and State primacy obligations

3. Compliance with current regulations

M. Disinfection studies

1. New Giardia inactivation studies at high pH levels

2. Effectiveness of different disinfectants on Cryptosporidium

3. New virus inactivation studies

III. Economic Analysis of M-DBP Advisory Committee Recommendations

A. Overview of RIA for proposed rule

B. What's changed since proposed rule

C. Summary of cost analysis

1. Total national costs

2. Household costs

D. Cost of turbidity performance criteria & associated monitoring

1. System level impact analysis

2. National impact analysis

a. decision tree

b. utility costs

c. State costs

E. Disinfection benchmark

1. Decision tree

2. Utility costs

3. State costs

F. Sanitary surveys

G. Summary of benefits analysis

IV. National Technology Transfer and Advancement Act

I. Introduction and Background

A. Existing Regulations

1. Surface Water Treatment Rule

Under the Surface Water Treatment Rule (SWTR)(54 FR 27486, June 29,

1989), USEPA set maximum contaminant level goals of zero for Giardia

lamblia, viruses, and Legionella; and promulgated national primary

drinking water regulations for all public water systems (PWSs) using

surface water sources or ground water sources under the direct

influence of surface water. The SWTR includes treatment technique

requirements for filtered and unfiltered systems that are intended to

protect against the adverse health effects of exposure to Giardia

lamblia, viruses, and Legionella, as well as many other pathogenic

organisms. Briefly, those requirements include (1) removal or

inactivation of 3 logs (99.9%) for Giardia and 4 logs (99.99%) for

viruses; (2) combined filter effluent performance of 5 NTU as a maximum

and 0.5 NTU at 95th percentile monthly, based on 4-hour monitoring for

treatment plants using conventional treatment or direct filtration

(with separate standards for other filtration technologies); and (3)

watershed protection and other requirements for unfiltered systems.

2. Total Trihalomethane MCL

USEPA set an interim Maximum Contaminant Level (MCL) for total

trihalomethanes (TTHM) of 0.10 mg/l as an annual average in November

1979 (44 FR 68624). This standard was based on the need to balance the

requirement for continued disinfection of water to reduce exposure to

pathogenic microorganisms while simultaneously lowering exposure to

disinfection byproducts which might be carcinogenic to humans.

The interim TTHM standard only applies to any PWSs (surface water

and/or ground water) serving at least 10,000 people that add a

disinfectant to the drinking water during any part of the treatment

process. At their discretion, States may extend coverage to smaller

PWSs. However, most States have not exercised this option. About 80

percent of the PWSs, serving populations of less than 10,000, are

served by ground water that is generally low in THM precursor content

(USEPA, 1979) and which would be expected to have low TTHM levels even

if they disinfect.

3. Total Coliform Rule

The Total Coliform Rule (54 FR 27544; June 29, 1989), revised in

June 1989 and effective on December 31, 1990 applies to all public

water systems (USEPA, 1989b). This regulation sets compliance with the

Maximum Contaminant Level (MCL) for total coliforms as follows. For

systems that collect 40 or more samples per month, no more than 5.0% of

the samples may be total coliform-positive; for those that collect

fewer than 40 samples, only one sample may be total coliform-positive.

If a system exceeds the MCL for a month, it must notify the public

using mandatory language developed by the USEPA. The required

monitoring frequency for a system ranges from 480 samples per month for

the largest systems to once annually for certain of the smallest

systems. All systems must have a written plan identifying where samples

are to be collected. In addition, systems are required to conduct

repeat sampling after a positive sample.

The Total Coliform Rule also requires each system that collects

fewer than five samples per month to have the system inspected every 5

years (10 years for certain types of systems using only protected and

disinfected ground water.) This on-site inspection (referred to as a

sanitary survey) must be performed by the State or by an agent approved

by the State.

4. Information Collection Rule

The Information Collection Rule (ICR) is a monitoring and data

reporting rule that was promulgated on May 14, 1996 (61 FR 24354)

(USEPA, 1996b). The purpose of the ICR is to collect occurrence and

treatment information to evaluate the need for possible changes to the

current Surface Water Treatment Rule and existing microbial treatment

practices and to evaluate the need for future regulation for

disinfectants and DBPs. The ICR will provide USEPA with additional

information on the national occurrence in drinking water of (1)

chemical byproducts that form when disinfectants used for microbial

control react with compounds already present in source water and (2)

disease-causing microorganisms, including Cryptosporidium, Giardia, and

viruses. The ICR will also collect engineering data on how PWSs

currently control such contaminants. This information is being

collected because the regulatory negotiation on disinfectants and DBPs

concluded that additional information was needed to assess the

potential health problem created by the presence of DBPs and pathogens

in drinking water and to assess the extent and severity of risk in

order to make sound regulatory and public health decisions. The ICR

will also provide information to support regulatory impact analyses for

various regulatory options, and to help develop monitoring strategies

for cost effectively implementing regulations.

B. Public Health Concerns To Be Addressed

In 1990, USEPA's Science Advisory Board (SAB), an independent panel

of experts established by Congress, cited

[[Page 59489]]

drinking water contamination as one of the most important environmental

risks and indicated that disease-causing microbial contaminants (i.e.,

bacteria, protozoa and viruses) are probably the greatest remaining

health risk management challenge for drinking water suppliers (USEPA/

SAB 1990). This view was prompted by the SAB's concern about the number

of waterborne disease outbreaks in the U.S. Between 1980 and 1994, 379

waterborne disease outbreaks were reported, with over 500,000 cases of

disease. During this period, a number of agents were implicated as the

cause, including protozoa, viruses and bacteria, as well as several

chemicals. Most of the cases (but not outbreaks) were associated with

surface water, and specifically with a single outbreak of

cryptosporidiosis in Milwaukee (over 400,000 cases) (Craun, Pers. Comm.

1997a).

The number of waterborne disease outbreaks and cases is, however,

probably much greater than that recorded because the vast majority of

waterborne disease is probably not reported. Few States have an active

outbreak surveillance program and disease outbreaks are often not

recognized in a community or, if recognized, are not traced to the

drinking water source. This situation is complicated by the fact that

the vast majority of people experiencing gastrointestinal illness

(predominantly diarrhea) do not seek medical attention. For those who

do, physicians generally cannot attribute gastrointestinal illness to

any specific origin such as a drinking water source. An unknown but

probably significant portion of waterborne disease is endemic, i.e.,

not associated with an outbreak, and thus is even more difficult to

recognize.

One of the key regulations USEPA has developed and implemented to

counter pathogens in drinking water is the SWTR. Among its provisions,

the rule requires that a public water system have sufficient treatment

to reduce the source water concentration of Giardia and viruses by at

least 99.9% (3 logs) and 99.99% (4 logs), respectively.

The goal of the SWTR is to reduce risk to less than one infection

per year per 10,000 people (10-4). However, one of the

SWTR's shortcomings is that the source waters of some systems have high

pathogen concentrations that, when reduced by the levels required under

the rule, still may not meet a common health goal (e.g.,

10-4).

Another shortcoming of the SWTR is that the rule does not

specifically control for the protozoan Cryptosporidium. The first

report of a recognized outbreak caused by Cryptosporidium was published

during the development of the SWTR (D'Antonio et al., 1985). Other

outbreaks caused by this pathogen have since been reported both in the

United States and other countries (Smith et al.,1988; Hayes et al.,

1989; Levine and Craun, 1990; Moore et al., 1993; Craun, 1993). A

particular public health challenge is that simply increasing existing

disinfection levels above those most commonly practiced in the United

States today does not appear to be an effective strategy for

controlling Cryptosporidium.

In addition to these issues, there is another potentially counter-

balancing public health concern. The disinfectants used to control

microbial pathogens may produce toxic or carcinogenic disinfection

byproducts (DBPs) when they react with organic chemicals in the source

water. Thus, an important question facing water supply professionals is

how to minimize the risk from both microbial pathogens and DBPs

simultaneously.

At the time the SWTR was promulgated, USEPA had limited data

concerning Giardia and Cryptosporidium occurrence in source waters and

treatment efficiencies. The 3-log removal/inactivation of Giardia

lamblia and 4-log removal/inactivation of enteric viruses required by

the SWTR were developed to provide protection from most pathogens in

source waters. However, additional data has become available since

promulgation of the SWTR concerning source water occurrence and

treatment efficiencies for Giardia, as well as for Cryptosporidium

(LeChevallier et al. 1991 a,b). A major concern is that if systems

currently provide four or more logs of removal/inactivation for

Giardia, such systems might reduce existing levels of disinfection to

more easily meet new DBP regulations, and thus only marginally meet the

three-log removal/inactivation requirement for Giardia lamblia

specified in the current SWTR. Depending upon source water Giardia

concentrations, such treatment changes could lead to significant

increases in microbial risk (Regli et al., 1993; Grubbs et al., 1992;

USEPA, 1994b).

C. Statutory Provisions

1. SDWA and 1986 Provisions

The Safe Drinking Water Act (SDWA or the Act), as amended in 1986,

requires USEPA to publish a ``maximum contaminant level goal'' (MCLG)

for each contaminant which, in the judgement of the USEPA

Administrator, ``may have any adverse effect on the health of persons

and which are known or anticipated to occur in public water systems''

(Section 1412(b)(3)(A)). MCLGs are to be set at a level at which ``no

known or anticipated adverse effect on the health of persons occur and

which allows an adequate margin of safety'' (Section 1412(b)(4)).

The Act also requires that at the same time USEPA publishes an

MCLG, which is a non-enforceable health goal, it also must publish a

National Primary Drinking Water Regulation (NPDWR) that specifies

either a maximum contaminant level (MCL) or treatment technique

(Sections 1401(1) and 1412(a)(3)). USEPA is authorized to promulgate a

NPDWR ``that requires the use of a treatment technique in lieu of

establishing a MCL,'' if the Agency finds that ``it is not economically

or technologically feasible to ascertain the level of the

contaminant''.

Section 1414 (c) of the Act requires each owner or operator of a

public water system to give notice to the persons served by the system

of any failure to comply with an MCL or treatment technique requirement

of, or testing procedure prescribed by, a NPDWR and any failure to

perform monitoring required by section 1445 of the Act.

Section 1412(b)(7)(C) of the SDWA requires the USEPA Administrator

to publish a NPDWR ``specifying criteria under which filtration

(including coagulation and sedimentation, as appropriate) is required

as a treatment technique for public water systems supplied by surface

water sources''. In establishing these criteria, USEPA is required to

consider ``the quality of source waters, protection afforded by

watershed management, treatment practices (such as disinfection and

length of water storage) and other factors relevant to protection of

health''. This section of the Act also requires USEPA to promulgate a

NPDWR requiring disinfection as a treatment technique for all public

water systems and a rule specifying criteria by which variances to this

requirement may be granted.

2. Changes to Initial Provisions and New Mandates

In 1996, Congress reauthorized the Safe Drinking Water Act. Several

of the 1986 provisions discussed above were renumbered and augmented

with additional language, while other sections mandate new drinking

water requirements. These modifications, as well as new provisions, are

detailed below.

As part of the 1996 amendments to the Safe Drinking Water Act (the

Amendments), USEPA's general

[[Page 59490]]

authority to set a MCLG and NPDWR was modified to apply to contaminants

that may ``have an adverse effect on the health of persons'', that are

``known to occur or there is a substantial likelihood that the

contaminant will occur in public water systems with a frequency and at

levels of public health concern'', and for which ``in the sole

judgement of the Administrator, regulation of such contaminant presents

a meaningful opportunity for health risk reduction for persons served

by public water systems' (1986 SDWA Section 1412 (b)(3)(A) stricken and

amended with 1412(b)(1)(A)).

The Amendments also require that USEPA, when proposing a NPDWR that

includes an MCL or treatment technique, publish and seek public comment

on health risk reduction and cost analyses. The Amendments also require

USEPA to take into consideration the effects of contaminants upon

sensitive subpopulations (i.e. infants, children, pregnant women, the

elderly, and individuals with a history of serious illness), and other

relevant factors. (Section 1412 (b)(3)(C)).

The 1996 Amendments also newly require USEPA to promulgate an

Interim Enhanced SWTR and a Stage I Disinfectants and Disinfection

Byproducts Rule by November 1998. In addition, the 1996 Amendments

require USEPA to promulgate a Final Enhanced SWTR and a Stage 2

Disinfection Byproducts Rule by November 2000 and May 2002,

respectively (Section 1412(b)(2)(C)).

Under the Amendments of 1996, recordkeeping requirements were

modified to apply to ``every person who is subject to a requirement of

this title or who is a grantee'' (Section 1445 (a)(1)(A)). Such persons

are required to ``establish and maintain such records, make such

reports, conduct such monitoring, and provide such information as the

Administrator may reasonably require by regulation . . .''.

D. Regulatory Negotiation Process

In 1992 USEPA initiated a negotiated rulemaking to develop a

disinfectants/disinfection byproducts rule. The negotiators included

representatives of State and local health and regulatory agencies,

public water systems, elected officials, consumer groups and

environmental groups. The Committee met from November 1992 through June

1993.

Early in the process, the negotiators agreed that large amounts of

information necessary to understand how to optimize the use of

disinfectants to concurrently minimize microbial and DBP risk on a

plant-specific basis were unavailable. Nevertheless, the Committee

agreed that USEPA propose a disinfectants/disinfection byproducts rule

to extend coverage to all community and nontransient noncommunity water

systems that use disinfectants. This rule proposed to reduce the

current TTHM MCL, regulate additional disinfection byproducts, set

limits for the use of disinfectants, and reduce the level of organic

compounds in the source water that may react with disinfectants to form

byproducts.

One of the major goals addressed by the Committee was to develop an

approach that would reduce the level of exposure from disinfectants and

DBPs without undermining the control of microbial pathogens. The

intention was to ensure that drinking water is microbiologically safe

at the limits set for disinfectants and DBPs and that these chemicals

do not pose an unacceptable risk at these limits.

Following months of intensive discussions and technical analysis,

the Committee recommended the development of three sets of rules: a

two-staged Disinfectants/Disinfection Byproduct Rule (proposal: 59 FR

38668, July 29, 1994) (USEPA, 1994a), an ``interim'' ESWTR (proposal:

59 FR 38832, July 29, 1994) (USEPA, 1994b), and an Information

Collection rule (proposal: 59 FR 6332, February 10, 1994) (USEPA,

1994c). The IESWTR would only apply to systems serving 10,000 people or

more. The Committee agreed that a ``long-term'' ESWTR (LTESWTR) would

be needed for systems serving fewer than 10,000 people when the results

of more research and water quality monitoring became available. The

LTESWTR could also include additional refinements for larger systems.

The approach in developing these proposals considered the

constraints of simultaneously treating water to control for both

microbial contaminants and DBPs. As part of this effort, the

Negotiating Committee concluded that the SWTR may need to be revised to

address health risk from high densities of pathogens in poorer quality

source waters and from the protozoan, Cryptosporidium. The Committee

also agreed that the schedules for IESWTR and LTESWTR should be

``linked'' to the schedule for the Stage 1 DBP Rule to assure

simultaneous compliance and a balanced risk-risk based implementation.

The Committee agreed that additional information on health risk,

occurrence, treatment technologies, and analytical methods needed to be

developed in order to better understand the risk-risk tradeoff, and how

to accomplish an overall reduction in risk.

Finally the Negotiating Committee agreed that to develop a

reasonable set of rules and to understand more fully the limitations of

the current SWTR, additional field data were critical. Thus, a key

component of the regulation negotiation agreement was the promulgation

of the Information Collection Rule (ICR) noted above and described in

more detail below.

E. Information Collection Rule

As stated above, the ICR established monitoring and data reporting

requirements for large public water systems serving populations over

100,000. About 350 PWSs operating 500 treatment plants are involved in

the data collection effort. Under the ICR, these PWSs monitor their

source water for bacteria, viruses, and protozoa (surface water sources

only); water quality factors affecting DBP formation; and DBPs within

the treatment plant and in the distribution system. In addition, PWSs

must provide operating data and a description of their treatment plan

design. Finally, a subset of PWSs perform treatment studies, using

either granular activated carbon or membrane processes, to evaluate DBP

precursor removal. Monitoring for treatment study applicability began

in September 1996. The remaining occurrence monitoring began in July

1997.

The initial intent of the ICR was to collect monitoring data and

other information for use in developing the Stage 2 DBPR and IESWTR and

to estimate national costs for various treatment options. However,

because of delays in promulgating the ICR and technical difficulties

associated with laboratory approval and review of facility sampling

plans, most ICR monitoring did not begin until July 1, 1997. As a

result of this delay and the new Stage 1 DBPR and IESWTR deadlines

specified in the 1996 SDWA amendments, ICR data will not be available

for analysis in connection with these rules. In place of the ICR data,

the Agency has worked with stakeholders to identify additional data

developed since 1994 that can be used in components of these rules.

USEPA intends to continue to work with stakeholders in analyzing and

using the comprehensive ICR data and research for developing subsequent

revisions to the SWTR and the Stage 2 DBP Rule.

F. Formation of 1997 Federal Advisory Committee

In May 1996, the Agency initiated a series of public informational

meetings to exchange information on issues

[[Page 59491]]

related to microbial and disinfectants/disinfection byproducts

regulations. To help meet the deadlines for the IESWTR and Stage 1 DBPR

established by Congress in the 1996 SDWA Amendments and to maximize

stakeholder participation, the Agency established the Microbial and

Disinfectants/Disinfection Byproducts (M-DBP) Advisory Committee under

the Federal Advisory Committee Act (FACA) on February 12, 1997, to

collect, share, and analyze new information and data, as well as to

build consensus on the regulatory implications of this new information.

The Committee consists of 17 members representing USEPA, State and

local public health and regulatory agencies, local elected officials,

drinking water suppliers, chemical and equipment manufacturers, and

public interest groups.

The Committee met five times, in March through July 1997, to

discuss issues related to the IESWTR and Stage 1 DBPR. Technical

support for these discussions was provided by a Technical Work Group

(TWG) established by the Committee at its first meeting in March 1997.

The Committee's activities resulted in the collection, development,

evaluation, and presentation of substantial new data and information

related to key elements of both proposed rules. The Committee reached

agreement on the following major issues discussed in this Notice and

the Notice for the Stage 1 DBPR published elsewhere in today's Federal

Register: (1) MCLs for TTHMs, HAA5 and bromate; (2) requirements for

enhanced coagulation and enhanced softening (as part of DBP control);

(3) microbial benchmarking/profiling to provide a methodology and

process by which a PWS and the State, working together, assure that

there will be no significant reduction in microbial protection as the

result of modifying disinfection practices in order to meet MCLs for

TTHM and HAA5; (4) disinfection credit; (5) turbidity; (6)

Cryptosporidium MCLG; (7) removal of Cryptosporidium; (8) role of

Cryptosporidium inactivation as part of a multiple barrier concept and

(9) sanitary surveys. The Committee's recommendations to USEPA on these

issues were set forth in an Agreement In Principle document dated July

15, 1997. This document is included with this notice as Appendix 1.

G. Overview of IESWTR 1994 Proposal

1. Summary of Major Elements

As part of the IESWTR July 29, 1994, Federal Register notice (59 FR

38832), USEPA proposed to revise the SWTR to provide additional

protection against pathogens in drinking water. USEPA proposed to set

the MCLG for Cryptosporidium at zero based on animal studies and human

epidemiology studies of waterborne outbreaks of cryptosporidiosis. The

proposal also focused on treatment requirements for the waterborne

pathogens Giardia lamblia, Cryptosporidium, Legionella and viruses that

would apply to all public water systems that use surface water or

ground water under the influence of surface water and serve 10,000

people or more. Major features of the proposal included a stricter

watershed control requirement for systems using surface water that wish

to avoid filtration; a change in the definition of ground water under

the influence of surface water to include the presence of

Cryptosporidium; a periodic sanitary survey requirement for all systems

using surface water or ground water under the influence of surface

water; and several alternative requirements, described below, for

augmenting treatment control of Giardia lamblia, Cryptosporidium, and

viruses. USEPA also requested comment on several supplemental

provisions and on other related issues, described below.

2. Alternative Treatment Requirements

USEPA proposed five treatment alternatives for controlling Giardia

lamblia, Cryptosporidium, and viruses. Each alternative included

several options. Alternative A addressed enhanced treatment for Giardia

lamblia only. Alternatives B and C addressed treatment for

Cryptosporidium only. Alternative D addressed enhanced treatment for

viruses only. Alternative E would maintain existing levels of treatment

for Giardia lamblia and viruses.

a. Alternative A. Enhanced treatment for Giardia lamblia. The SWTR

currently requires a 99.9 percent (3-log) removal/inactivation of

Giardia lamblia for all surface waters, regardless of Giardia lamblia

cyst concentrations in the source water. Under Alternative A, the

minimum level of treatment a system would be required to provide (e.g.,

3, 4, 5 or 6 log removal/inactivation) would depend on the Giardia

lamblia density in the source water as determined by monitoring over

some specified interval of time. The level of prescribed treatment for

a particular system would correspond to providing water below an annual

risk level for Giardia lamblia infections (e.g. 10-4).

b. Alternative B. Specific Treatment for Cryptosporidium. USEPA

also proposed a treatment technique for Cryptosporidium similar to the

proposal for Giardia under Alternative A, such that the required level

of Cryptosporidium treatment for any particular system would depend on

the density of Cryptosporidium in the source water.

c. Alternative C. 99% (2-log) removal of Cryptosporidium. Under

this alternative, USEPA would require systems to achieve at least a 99%

(2-log) removal of Cryptosporidium by filtration (with pretreatment).

The 2-log level was based on the premise that a 3-log level (as

currently required for Giardia removal/inactivation) is not

economically or technologically possible, since data suggests that

Cryptosporidium is consistently more resistant to disinfection than is

Giardia. USEPA indicated that it would continue to assess new field and

laboratory data to control Cryptosporidium by physical removal and

disinfection for consideration in subsequent microbial regulations.

d. Alternative D. Specific disinfection treatment for viruses. The

SWTR required systems to achieve a four-log removal/inactivation of

viruses. This is to be achieved through a combination of filtration and

disinfection or, for systems not required to filter their source

waters, by disinfection alone. However, this level of treatment may not

be adequate to achieve a particular health risk (e.g., 10-4

infections/yr/person) for viruses. Viruses are of particular concern,

given that one or several virus particles may be infectious (Regli et

al.,1991) and that several enteric viruses are associated with

relatively high mortality rates (Bennett et al., 1987). Failure or

impairment of filtration performance could allow substantial pathogen

contamination of drinking water, particularly if the disinfection

barrier following filtration is minimal.

Alternative D would require that systems provide sufficient

disinfection such that disinfection alone would achieve at least a 0.5-

log inactivation of Giardia lamblia or, alternatively, a 4-log

inactivation of viruses. This proposed approach would be independent of

the level of physical removal or the source water density of viruses.

If the filtration process was able to remove three logs of Giardia

lamblia, a system would still have to provide at least an additional

0.5-log inactivation of Giardia lamblia or 4-log inactivation of

viruses by disinfection.

e. Alternative E. No change to existing SWTR treatment requirements

for Giardia lamblia and viruses. Alternative E maintains existing SWTR

levels of

[[Page 59492]]

treatment for Giardia lamblia and viruses. USEPA could regulate

Cryptosporidium directly (e.g., Alternative C above) or make a finding

that existing SWTR filtration and disinfection requirements are

adequate to control this organism.

3. Possible Supplemental Treatment Requirements

USEPA also requested comment on three supplemental requirements

regarding uncovered finished water reservoirs, cross connection control

and State notification of turbidity levels.

a. Uncovered Finished Water Reservoirs. As part of the 1994

proposal, USEPA requested comment on possible supplemental requirements

for uncovered finished water reservoirs. The Agency noted that USEPA

guidelines recommend that all finished water reservoirs be covered

(USEPA, 1991a) and that the American Water Works Association (AWWA)

also has issued a policy statement that strongly supports the covering

of such reservoirs (AWWA, 1993).

b. Cross Connection Control Program. USEPA requested comment on

whether to require States or public water systems to have cross

connection control programs. Plumbing cross-connections are actual or

potential connections between a potable and non-potable water supply

(USEPA, 1989a). According to Craun (1991), 24% of the waterborne

disease outbreaks that occurred during 1981-1990 were caused by water

contamination in the distribution system, primarily as the result of

cross-connections and main repairs.

c. State Notification of High Turbidity Levels. USEPA also

requested comment on whether to require systems to notify the State as

soon as possible for persistent turbidity levels above the performance

standards or for any other situation that is not now a violation of the

turbidity standards. Under the SWTR, any time the turbidity of a

treatment plant's combined filter effluent exceeds 5 NTU the system

must notify the State as soon as possible, but no later than the end of

the next business day. In addition, the system must notify the public

as soon as possible, but in no case later than 14 days after the

violation.

USEPA indicated in the proposal that it was considering broadening

the requirement for State notification. The Agency suggested it might,

for example, require systems to notify the State as soon as possible if

at any point during the month it becomes apparent that a system will

violate the monthly 95th percentile turbidity performance standard

specified in the SWTR, rather than wait to the end of the month.

USEPA outlined a number of public health reasons for requiring

swift State notification for persistent turbidity levels. Pathogens may

accompany the turbidity particles that exit the filters, especially

with poor quality source waters. High turbidity levels in the filtered

water, even for a limited time, may represent a significant risk to the

public. USEPA's proposed approach was intended to allow States to

respond in controlling a potentially serious problem more quickly.

4. Other related issues. The Agency also requested comments on

other issues related to possible IESWTR options. A number of these are

listed below.

(a) To what extent should the ESWTR address the issue of recycling

filter backwash, given its potential for increasing the densities of

Giardia lamblia and Cryptosporidium on the filter?

(b) Should the ESWTR define minimum certification criteria for

surface water treatment plant operators? Currently the SWTR (40 CFR

141.70) requires such systems to be operated by ``qualified personnel

who meet the requirements specified by the State.''

(c) What criteria, if any, should the ESWTR include to ensure that

systems optimize treatment plant performance?

(d) Should turbidity performance criteria be modified? Should

criteria pertain to individual filters?

(e) Should the rule include a performance standard for particle

removal?

(f) Should the rule include a requirement for an early warning for

high turbidity?

(g) Under what conditions could systems be allowed different log

removal credits than is currently recommended in the SWTR Guidance

Manual?

(h) How should USEPA decide, in developing a Notice of Data

Availability, what treatment approach(es) is most suitable for

additional public comment?

II. New Information and Key Issues to be Addressed

A. MCLG for Cryptosporidium

1. Summary of 1994 Proposal and Public Comments

The July 29, 1994, Federal Register notice proposed to set the MCLG

for Cryptosporidium at zero. The purpose of the MCLG is to protect

public health. The reasons for this determination were based upon

animal studies and human epidemiology studies of waterborne outbreaks

of cryptosporidiosis.

Most commenters supported an MCLG of zero for Cryptosporidium.

Those who provided reasons stated that (1) a single cell could infect,

and data do not support a threshold dose below which an outbreak or

disease will not occur, (2) the organism is present in water and has

caused major waterborne disease outbreaks, and (3) it is consistent

with the goals set under the SWTR and Total Coliform Rule. Commenters

who opposed the proposed MCLG stated that USEPA needed more health risk

and organism/disease transmission data and better analytical methods

before setting an MCLG and regulating Cryptosporidium.

2. New data and Perspectives

Since publication of the proposed rule, results of a human feeding

study have become available. Dupont et al. (1995) fed 29 healthy

volunteers single doses ranging from 30 to 1 million C. parvum oocysts

obtained from a calf. Of the 16 volunteers who received 300 or more

oocysts, 88% became infected. Of the five volunteers who received the

lowest dose (30 oocysts), one became infected. The median infective

dose was 132 oocysts. According to a mathematical model based upon the

Dupont et al. data, 0.5% of a population exposed to an average dose of

one oocyst, would be expected to become infected. (Haas et al., 1996).

An important concern is that certain populations are at greater

risk of waterborne disease infection than others. These vulnerable

populations include the immunocompromised; children, especially the

very young; the elderly; and pregnant women (Gerba et al. 1996; Fayer

and Ungar 1986). The most significant segment within these vulnerable

populations with regard to cryptosporidiosis is people who are

immunocompromised. In patients with severely weakened immune systems,

(e.g cancer, AIDS patients), cryptosporidiosis can be serious, long-

lasting and sometimes fatal. There is concern about cryptosporidiosis

in immunocompromised individuals because currently there is no cure for

the disease.

C. parvum is the only Cryptosporidium species known for certain to

infect humans. One controversial report (the only one of its kind)

found evidence that C. baileyi, which infects birds, was present in the

stools and other autopsied organs of an immunodeficient patient

(Ditrich et al., 1991). There was no indication that Cryptosporidium

had been responsible in this instance for any adverse health effects.

C. parvum also infects many other mammals. While C. parvum is a

[[Page 59493]]

well-documented human pathogen, strain variation may occur and one

strain may cause infection and/or disease at a higher or lower

concentration than other strains. USEPA is currently funding research

[Cryptosporidium virulence study using different strains, Herbert

Dupont] to examine this issue.

There is some question about the taxonomy (i.e., classification) of

species within the genus Cryptosporidium. Up until 1980, classification

was based on the assumption that a particular species only infected one

type of animal. This assumption appears to be incorrect; hence other

appropriate taxonomy schemes have been suggested.

An important issue not directly related to the MCLG involves the

measurement of C. parvum in water. With current technology, it is often

very difficult to distinguish between viable and non-viable oocysts.

When Cryptosporidium is identified it is often not clear whether it is

C. parvum or another species. Several Cryptosporidium species look

similar to C. parvum and react to ``specific'' C. parvum stains in a

like manner (cross-reactions). In addition, it can be difficult to

distinguish Cryptosporidium from alga and invertebrate eggs (Clancy et

al. 1994)

3. Advisory Committee Recommendations and Related Issues

The M-DBP Federal Advisory Committee supported the proposed

establishment of a Cryptosporidium MCLG at zero. However, a key issue

identified by the Committee and public commenters is whether the MCLG

should be set at the genus level (i.e., Cryptosporidium), as proposed,

or at the more specific species level (i.e., C. parvum). Setting the

MCLG at the genus level would automatically include any Cryptosporidium

species other than C. parvum that is later found to be pathogenic to

humans. In contrast, setting an MCLG at the species level would

indicate that only C. parvum infects humans, and would also be

consistent with the approach taken under the SWTR for Giardia where the

MCLG is set at the species level (i.e., G. lamblia). USEPA has not

decided which approach is most appropriate and seeks public comment on

this issue.

As indicated above, USEPA's intent in establishing this MCLG at

zero is to protect public health. The Agency believes there is adequate

research data to support this determination. However, as noted above,

the Agency recognizes that there is scientific uncertainty on the issue

of Cryptosporidium taxonomy and on the question of cross reactions

between species. USEPA expects further clarification on this issue as

research continues, Cryptosporidium analytical methods improve, and

more is learned about the circumstances under which cross-reactivity

between species occurs. The Agency also wishes to emphasize that the

scope or specificity of the MCLG may be modified in the future to

reflect new research and additional information about particular

species that represent a significant risk to human health.

As part of this notice, USEPA requests comment on whether to

establish a Cryptosporidium MCLG at the genus level as proposed or at

the species level (i.e., Cryptosporidium vs. Cryptosporidium parvum).

USEPA also requests copies of any additional research, data or other

information related to this issue.

B. Removal of Cryptosporidium by Filtration

1. Summary of 1994 Proposal and Public Comments Received

One of USEPA's proposed treatment Alternatives (Alternative C)

would require filtered systems to achieve at least a 2 log removal of

Cryptosporidium oocysts. USEPA recognized that the proposed removal

level was based on limited data and therefore solicited comment on

whether other minimum removal levels might be appropriate.

Most commenters addressing the issue of treatment alternatives

supported Alternative C. Some commenters opposed any treatment

requirement greater than a 2 log removal due to a lack of better

understanding of dose-response, effectiveness of treatment, and

analyses to justify the higher treatment costs involved.

Other commenters referred to specific studies (Nieminski 1995;

Patania et al., 1995) that provided additional information on

Cryptosporidium removal. One commenter cited a study (Parker and Smith,

1993), where oocyst damage was observed after agitation with sand. This

study postulated that oocysts may be damaged as they pass through the

filtration media. This commenter also pointed to the lack of data on

cyst removal by full-scale plants and recommended that additional

research be conducted. Some commenters recognized the need to regulate

Cryptosporidium, but opposed having the level of treatment based upon

source water pathogen density (alternative B). One commenter indicated

that further implementation and evaluation of the adequacy of the SWTR

needs to occur before modifying it.

2. New Data and Perspectives

a. Rapid Granular Filtration. Table 1 summarizes research pertinent

to Cryptosporidium and Giardia lamblia removal efficiencies by rapid

granular filtration. Brief descriptions of these studies and a summary

of key points follow.

Table 1.--Cryptosporidium and Giardia Lamblia Removal Efficiencies by Rapid Granular Filtration

----------------------------------------------------------------------------------------------------------------

Type of treatment plant Log removal Experimental design Researcher

----------------------------------------------------------------------------------------------------------------

Conventional filtration plants... Crypt 2.7-5.9....... Pilot Plants....... Patania et al. 95.

Do........................... Giardia 3.4-5.8..... ......do........... Do.

Do........................... Crypt 2.3-3.0....... Pilot scale plant.. Nieminski/Ongerth 95.

Do........................... Giardia 3.3-3.4..... +full scale plant Do.

with seeded cysts/

oocysts.

Do........................... Crypt 2.7-3.1....... Pilot Plants....... Ongerth/Pecaroro 95.

Do........................... Giardia 3.1-3.5..... ......do........... Do.

Do........................... Crypt 2-2.5......... Full scale plants.. LeChevallier et al. 91b.

Do........................... Giardia 2-2.5....... Full scale plants.. LeChevallier et al. 91b.

Do........................... Crypt 2.3-2.5....... Full scale plants.. LeChevallier/Norton 92.

Do........................... Giardia 2.2-2.8..... ......do........... Do.

Do........................... Crypt 2-3........... Pilot scale plant.. Foundation for Water.

Research 94.

Do........................... Giardia and......... Full scale plant... Kelley et al. 95.

DoCrypt 1.5-2................ operation considered

ot optimized).

Direct filtration plants......... Crypt 1.5-4.0....... Pilot Plants....... Patania et al. 1995.

Do........................... Giardia 1.5-4.8..... ......do........... Do.

[[Page 59494]]

Do........................... Crypt 2.8-3.0....... ......do........... Nieminski/Ongerth 95.

Do........................... Giardia 3.3-3.9..... ......do........... Do.

Do........................... Crypt 2-3........... ......do........... West et al. 1994.

----------------------------------------------------------------------------------------------------------------

Patania, Nancy L; et al. 1995

Raw water turbidities were between 0.2 and 13. When treatment

conditions were optimized for turbidity and particle removal at four

different sites, Cryptosporidium removal ranged from 2.7 to 5.9 log and

Giardia removal ranged from 3.4 to 5.1 log during stable filter

operation. The median turbidity removal was 1.4 log, whereas the median

particle removal was 2 log. Median oocyst and cyst removal was 4.2 log.

A filter effluent turbidity of 0.1 NTU or less resulted in the most

effective cyst removal, by up to l log greater than when filter

effluent turbidities were greater than 0.1 NTU (within the 0.1 to 0.3

NTU range) (see Figures 1 and 2 below). Cryptosporidium removal rates

of less than 2.0 log (indicated in Figures 1 and 2) occurred at the end

of the filtration cycle.

Blackened data points in these figures represent data in which

oocysts were not detected in the filtered water. The log removal values

shown would be greater than indicated had the influent oocyst

concentration been sufficiently high to show oocyst detection in the

filtered water. The researchers also noted that removal of

Cryptosporidium was 0.4 to 0.9 log lower during filter ripening than

during stable filter operation; Giardia removal was generally 0.4 to

0.5 log lower during ripening. Cryptosporidium removal was 1.4 to 1.8

log higher for conventional treatment (including sedimentation) as

compared to direct filtration. Similarly, Giardia removal was 0.2 to

1.8 log higher. Figures 1 and 2 below show the log removal rates

discussed above.

BILLING CODE 6560-50-P

[[Page 59495]]

[GRAPHIC] [TIFF OMITTED] TP03NO97.043

[[Page 59496]]

[GRAPHIC] [TIFF OMITTED] TP03NO97.044

BILLING CODE 6560-50-C

Nieminski, Eva C. and Ongerth, Jerry E. 1995

This study evaluated performance in a pilot plant and in a full

scale plant (not in operation during the time of the study) and

considered two treatment modes: direct filtration and conventional

treatment. The source water of the full scale plant had turbidities

typically between 2.5 and 11 NTU with a peak level of 28 NTU. The

source water of the pilot plant typically had turbidities of 4 NTU with

a maximum of 23 NTU. For the pilot plant, achieving filtered water

turbidities between 0.1-0.2 NTU, Cryptosporidium removals averaged 3.0

log for conventional treatment and 3.0 log for direct filtration, while

the respective Giardia removals averaged 3.4 log and 3.3 log. For the

full scale plant, achieving similar filtered water turbidities,

Cryptosporidium removal averaged 2.25 log for conventional treatment

and 2.8 log for direct filtration, while the respective Giardia

removals averaged 3.3 log for conventional treatment and 3.9 log for

direct filtration. Differences in performance between direct filtration

and conventional treatment by the full scale plant were attributed to

different source water quality during the filter runs.

Ongerth, Jerry E. and Pecoraro, J.P. 1995

This project used very low turbidity source waters (0.35 to 0.58

NTU). With optimal coagulation, 3 log removal for both cysts were

obtained. In one test run, where coagulation was intentionally

suboptimal, the removals were only 1.5 log for Cryptosporidium and 1.3

log for Giardia. This emphasized the importance of proper coagulation

for cyst removal even though the effluent turbidity was less than 0.5

NTU.

LeChevallier, Mark W. and Norton, William D. 1992

Source water turbidities ranged from less than 1 to 120 NTU.

Removals of Giardia and Cryptosporidium (2.2-2.8 log) were slightly

less than those reported by other researchers, possibly because full

scale plants were studied, under less ideal conditions than the pilot

plants. The participating treatment plants were in varying stages of

treatment optimization. Removal achieved a median of 2.5 log for

Cryptosporidium and Giardia.

LeChevallier, Mark W.; Norton, William D.; and Lee, Raymond G. 1991b

This study evaluated removal efficiencies for Giardia and

Cryptosporidium in 66 surface water treatment plants in 14 States and 1

Canadian province. Most of the utilities achieved between 2 and 2.5 log

removals for both Giardia and Cryptosporidium. When no cysts were

detected on the finished water below detection protozoan levels were

set at the detection limit for calculating removal efficiencies.

Foundation for Water Research 1994

Raw water turbidity ranged from 1 to 30 NTU. Cryptosporidium oocyst

removal was between 2 and 3 log. Investigators concluded that any

measure which reduced filter effluent

[[Page 59497]]

turbidity should reduce risk from Cryptosporidium. The importance in

selecting coagulants, dosages, and pH should not be overlooked. Apart

from turbidity, indicators of possible reduced efficiency for oocyst

removal would be increased color and dissolved metal ion coagulant

concentration in the effluent, for these are indications of reduced

efficiency of coagulation/ flocculation.

Kelley, M.B. et al. 1995

Protozoa removal was between 1.5 and 2 log. The authors speculated

that this low Cryptosporidium removal occurred because the coagulation

process was not optimized, though the finished water turbidity was less

than 0.5 NTU. Also, when cysts were not detected in the finished water

below detection values were assumed as filtered water concentration

levels.

West, Thomas; et al. 1994

Pilot scale direct filtration was used with anthracite mono-media

at filtration rates of 6 and 14 gpm/sq ft. Raw water turbidity was 0.3

to 0.7 NTU. Removal efficiencies for Cryptosporidium at both filtration

rates were 2 log during filter ripening (despite turbidity exceeding

0.2 NTU), and 2 to 3 log for the stable filter run, declining

significantly during particle breakthrough. When effluent turbidity was

less than 0.1 NTU, removal typically exceeded 2 log. Log removal of

Cryptosporidium generally exceeded that for particle removal.

Summary of Studies

The studies described above indicate that rapid granular

filtration, when operated under appropriate coagulation conditions and

optimized to achieve a filtered water turbidity level of less than 0.3

NTU, should achieve at least 2 log of Cryptosporidium removal. Removal

rates vary widely, up to almost 6 log, depending upon water matrix

conditions, filtered water turbidity effluent levels, and where and

when removal efficiencies are measured within the filtration cycle. The

highest log pathogen removal rates occurred in those pilot plants and

systems which achieved very low finished water turbidities (less than

0.1 NTU).

Members of the M-DBP Advisory Committee discussed that tighter

turbidity performance criteria would increase the likelihood of systems

achieving higher oocyst removal rates. As a general principle, members

of the M-DBP Advisory Committee indicated that if a utility were

required to achieve less than 0.3 NTU 95% of the time, it would target

substantially lower turbidity levels in order to have confidence that

it will not exceed the 0.3 level. This principle was also recognized by

the M-DBP Advisory Committee's Technical Work Group and served as a

technical basis for much of the Committee's discussion of turbidity

(i.e., that if the performance standard is 0.3 NTU systems would target

achieving less than 0.2 NTU 95 percent of the time).

The Patania and Nieminski/Ongerth studies as they relate to

finished water turbidity levels and log removal are particularly

relevant to this point. These particular studies involve finished water

turbidity at low levels in the same range as the finished water target

identified by the Committee. The associated removal of Cryptosporidium

at these turbidity levels was reliably in the range of 2 log or

greater.

Other key points discussed during the Advisory Committee's

deliberations related to the studies include:

As turbidity performance improves for treatment of a

particular water, there tends to be greater removal of Cryptosporidium.

Pilot plant study data in particular indicate high

likelihood of achieving at least 2 log removal when plant operation is

optimized to achieve low turbidity levels. Moreover, pilot studies

represented in the table tend to be for low-turbidity waters, which are

considered to be the most difficult to treat regarding particulate

removal and associated protozoan removal. Since high removal rates have

been demonstrated in pilot studies using lower-turbidity source waters,

it is likely that similar or higher removal rates would be achieved for

higher-turbidity source waters.

The evaluation of Cryptosporidium removal in full-scale

plants can be difficult in that this data includes many non-detects in

the finished water. In these cases, values assigned at the detection

limit will likely result in over-estimation of oocysts in the finished

water. This in turn means that removal levels will tend to be under-

estimated.

Another factor that contributes to differences among the

data is that some of the full-scale plant data comes from plants that

are not optimized, but that still meet existing SWTR requirements. In

such cases, oocyst removal may be less than 2 log. In those studies

that indicate that full-scale plants are achieving greater than 2 log

removal (LeChevallier studies in particular), the following

characteristics pertain:

--Substantial numbers of filtered water measurements resulted in oocyst

detections;

--Source water turbidity tended to be relatively high compared to some

of the other studies;

--A significant percentage of these systems were also achieving low

filtered water turbidities, substantially less than 0.5 NTU.

Removal of Cryptosporidium can vary significantly in the

course of the filtration cycle (i.e., at the start-up and end of filter

operations versus the stable period of operation, which is the

predominant period).

b. Other Filtration Technologies. Other filtration technologies

include slow sand and diatomaceous earth filtration. ``Technologies and

Costs for the Treatment of Microbial Contaminants in Potable Water

Supplies, October 1988'' by USEPA (1988) listed research studies

indicating that a well designed and operated plant using these

technologies is capable of 3-to 4-log removal of Giardia and viruses.

Recent findings appear in Table 2 below.

Table 2.--Cryptosporidium and Giardia Lamblia Removal Efficiencies

----------------------------------------------------------------------------------------------------------------

Type of treatment plant Log removal Experimental design Researcher

----------------------------------------------------------------------------------------------------------------

Slow Sand........................ Giardia >3.......... Pilot plant at 4.5 Schuller and Ghosh, 91.

to.

Crypt >3............ 16.5 degrees C.....

Crypt 4.5........... Full scale plant... Timms et al., 1995

Diatomaceous Earth............... Giardia >3.......... Pilot plant, Schuler and Ghosh, 90.

addition of.

Crypt >3............ coagulant increased

.................. removal beyond.....

.................. values shown.......

----------------------------------------------------------------------------------------------------------------

[[Page 59498]]

c. Multiple Barrier Approach.

The M-DBP Advisory Committee engaged in extensive discussion

regarding the adequacy of relying solely on physical removal to control

Cryptosporidium in drinking water supplies and on the need for

inactivation. There was a substantial absence of technical consensus on

how to or whether it is currently possible to adequately measure

Cryptosporidium inactivation efficiencies for various disinfection

technologies. This issue emerged as a significant impediment to

addressing inactivation in the IESWTR.

As part of the original 1994 proposal, USEPA included control

strategies that would entail the development of a map of inactivation

efficiencies for Cryptosporidium. As discussed later in Section M. of

this Notice, adequate information to develop such a map is not

available at this time. The Advisory Committee discussion recognized,

however, that inactivation requirements may be appropriate and

necessary under future regulatory scenarios and that physical removal

by filtration may not be sufficient under all circumstances or for all

source waters.

As part of the development process for the long term ESWTR, the

Advisory Committee recommended that USEPA request comment on a risk-

based proposal for Cryptosporidium embodying the multiple barrier

approach (e.g., source water protection, physical removal,

inactivation, etc.), including, where risks suggest appropriate,

inactivation requirements. In establishing the LTESWTR, the Committee

recommended that the following issues be evaluated:

--Data and research needs and limitations (e.g., occurrence, treatment,

viability, active disease surveillance, etc.);

--Technology and methods capabilities and limitations;

--Removal and inactivation effectiveness;

--Risk tradeoffs including risks of significant shifts in disinfection

practices;

--Cost considerations consistent with the SDWA;

--Reliability and redundancy of systems; and

--Consistency with the requirements of the Act.

3. Advisory Committee Recommendations and Related Issues

USEPA reiterates its request for comment on the following

recommendations of the M-DBP Advisory Committee.

All surface water systems that serve more than 10,000 people and

are required to filter must achieve at least a 2-log removal of

Cryptosporidium. Systems which use rapid granular filtration (direct

filtration or conventional filtration treatment-as currently defined

in the SWTR), and meet the turbidity requirements described in

section II.C. are assumed to achieve at least a 2-log removal of

Cryptosporidium. Systems which use slow sand filtration and

diatomaceous earth filtration and meet existing turbidity

performance requirements under the SWTR (less than 1 NTU for the

95th percentile or alternative criteria as approved by the State)

are assumed to achieve at least 2-logs removal of Cryptosporidium.

Systems may demonstrate that they achieve higher levels of

physical removal.

C. Turbidity Control

1. Summary of 1994 Proposal as it Relates to Turbidity Issues and

Public Comments

Finished water turbidity levels are currently regulated by USEPA

under the SWTR as a treatment technique to ensure removal of Giardia

and viruses. The SWTR requires systems to monitor the turbidity of the

combined filter effluent every four hours at each treatment plant.

Systems using direct filtration or conventional treatment must achieve

a combined filter effluent turbidity level of no more than 0.5 NTU in

95% of the measurements in each month and never exceed 5 NTU. Failure

of individual filters may allow pathogens to enter the distribution

system. However, the SWTR does not presently require systems to monitor

the effluent of individual filters.

As a treatment technique, turbidity is an indicator of filtration

performance. Treatment plants are, as noted above, required to meet

certain turbidity levels to meet the removal requirements for Giardia.

Although turbidity is not a direct indicator of health risk, a very low

turbidity level of the treated water is in general a good indicator of

effective Cryptosporidium and Giardia oocyst and cyst removal by rapid

granular filtration. USEPA continues to believe that turbidity is the

most readily measurable parameter to indicate filtration treatment

effectiveness.

A primary focus of the 1994 proposal was the establishment of

treatment requirements that would address public health risks from high

densities of pathogens in poor quality source waters and from the

waterborne pathogen Cryptosporidium. As discussed earlier in this

Notice, waterborne pathogens have caused significant disease outbreaks

in the United States. Approaches outlined in the 1994 proposal included

treatment requirements based on site-specific concentrations of

pathogens in source water and a proposed 2-log removal requirement for

Cryptosporidium by filtration.

USEPA also specifically requested comment on what criteria, if any,

should be included to ensure that systems optimize treatment plant

performance and on whether any of the existing turbidity performance

criteria should be modified (e.g., should systems be required to base

compliance with the turbidity standards on individual filter effluent

monitoring in lieu of or in addition to monitoring the confluence of

all filters; and should any performance standard value be changed). In

addition, the Agency requested comment in the 1994 proposal on possible

supplemental requirements for State notification of persistent high

turbidity levels (e.g., broadening the requirements for State

notification of turbidity exceedances).

Some comments suggested and supported a revised approach to the

IESWTR that would focus on optimizing existing water treatment

processes to provide insurance against microbial disease outbreak in

the absence of source water occurrence data. Another comment suggested

that current levels of treatment, including filtration, have a

sufficient degree of effectiveness in preventing transmission of

Cryptosporidium in drinking water.

One commenter suggested that turbidity performance standards should

not be modified until the SWTR has been further implemented. One

commenter suggested that decreases in turbidity standards or monitoring

after each filter should be voluntary unless scientific data

demonstrate otherwise. Another commenter suggested that individual

filters can be evaluated during sanitary surveys. Several commenters

supported tighter turbidity standards and monitoring of individual

filters. Suggested turbidity performance levels included 0.1 or less,

or 0.2 NTU as revised standards. Several commenters supported

monitoring of individual filters, with one suggesting backwashing of

filters when turbidity levels increase.

2. New Data and Perspectives

As presented in detail below, the M-DBP Advisory Committee's

recommendations to the Agency included tighter turbidity performance

criteria and individual filter monitoring requirements as part of the

IESWTR. These revised performance criteria, along with the individual

filter monitoring requirements, would better enable systems to

demonstrate that they meet a 2 log removal requirement for

Cryptosporidium. Because Cryptosporidium is exceptionally

[[Page 59499]]

resistant to inactivation using chlorine, physical removal by

filtration is extremely important in controlling this organism. Data

presented in the previous section of this Notice support modifications

to the existing turbidity requirements under the SWTR to enable systems

to demonstrate that they meet the proposed 2 log requirement.

The revised turbidity performance criteria would also contribute to

another of the IESWTR's key objectives, which is to establish a

microbial backstop to prevent significant increases in microbial risk

when systems implement new disinfection byproduct standards under the

Stage 1 DBPR. As indicated by data presented below, tighter turbidity

performance criteria would reflect actual current performance for a

substantial percentage of systems nationally. Revising the turbidity

criteria would effectively ensure that these systems continue to

perform at these levels (in addition to resulting in improved

performance by systems that currently meet the existing criteria but

that operate at levels higher than those suggested in the Advisory

Committee's recommendations). The other major component of a microbial

backstop would be provisions for disinfection profiling and

benchmarking, which are discussed in Section D. of this Notice.

The revisions to the turbidity provisions (including the individual

filter provisions) recommended by the Committee would also contribute

to the microbial backstop objective in direct relationship to the

treatment process itself. The reliability of the disinfection barrier

as a means for preventing waterborne disease should increase

substantially as a result of these tighter turbidity provisions

because:

--There would be fewer and shorter periods of elevated turbidity during

which the disinfection barrier could be compromised; and

--The removal of particulate matter achieved by the filtration process

will both be higher on average and more consistent throughout the

treatment cycle, thus putting less burden on the disinfection barrier.

a. 95th Percentile and Maximum Turbidity Levels of Composite

Filtered Water.

Three data sets, summarizing the historical turbidity performance

of various filtration plants, were evaluated to assess the national

impact of modifying existing turbidity requirements. This included

turbidity information from the American Water Works Service Company

(AWWSC, 1997), a multi-State data set (which was analyzed in two sets)

(SAIC, 1997), and information from plants participating in the

Partnership for Safe Water program (Bissonette, 1997). Only turbidity

data from plants serving populations greater than 10,000 persons were

used. The analyses also included only plants that met the current 95th

percentile turbidity standard, 0.5 NTU, and the current maximum

turbidity standard, 5 NTU, in all months. Each of the data sets was

analyzed to assess the current performance of plants with respect to

the number of months in which selected 95th percentile and maximum

turbidity levels were exceeded.

The AWWSC is a privately-held company that owns and operates for

profit about 70 water treatment facilities located across the country.

For this analysis, the AWWSC data set (AWWSC, 1997) included one year's

data for 45 plants in 10 States. The States, with number of plants in

each state listed in parentheses, are as follows: California (1),

Connecticut (3), Iowa (2), Indiana (6), Maryland (1), Missouri (2),

Pennsylvania (24), Tennessee (1), Virginia (2), and West Virginia (3).

USEPA analyzed the composite filtered effluent turbidity data obtained

from the AWWSC plants measured every 4-hours.

The analyses examined two variations of turbidity data obtained

from the multi-State data set (SAIC, 1997). The multi-State data set

included 86 plants in 11 states. The States, with number of plants in

each state listed in parentheses, are as follows: California (10),

Georgia (5), Kansas (9), New Jersey (5), Ohio (12), Oregon (10), Rhode

Island (6), Texas (9), Wisconsin (8), West Virginia (6), Wyoming (6).

The State data was analyzed as two data sets, denoted as State 1 and

State 2. The State 1 data set included only plant information with

measurements every 4 hours, comprising slightly more than half of the

State data (47 plants in CA (10), OR (10), TX (9), WI (6), WY (6), WV

(6)). The State 2 data set was comprised of both the State 1 data and

other data including plant information consisting of daily maximum

turbidity values only, altogether 86 plants.

The State 1 data set was expected to provide a more accurate

picture of typical plant performance among the plants in the entire

State data set because there were more data points per plant. However,

the State 2 data set increased regional coverage by incorporating data

from five additional States (GA, KS, NJ, OH, RI) to reflect additional

geographic variation that may not have been captured in the State 1

data set.

In order to determine how many of the systems met lower 95th

percentile turbidity levels based on turbidity measurements every four

hours, the data from those States in which systems only report maximum

daily values had to be statistically adjusted. The adjustment is

necessary to take into account the difference in the number of reported

measurements in a month that can exceed a particular level (e.g., 0.3

NTU) without exceeding the monthly 95th percentile for that level.

(Systems that report measurements every four hours can have up to 9 of

180 measurements (5%) that exceed the level in a month; however, there

is no way to directly calculate an equivalent value for systems that

only report daily maximum values without making some adjustment.) No

adjustment was necessary for assessing monthly maximum turbidity

levels.

The State 2 analyses adjusted the monthly 95th percentile turbidity

levels for plants with only daily maximum data. This was done because

the 95th percentile based on 31 daily turbidity maximums a month will

overestimate the 95th percentile based on 186 daily measures (or

measurements every 4 hours). To assess the magnitude of the bias, the

State 1 data were used to examine the relationship between the 95th

percentile of the daily maximums and the 95th percentile of the daily

measurements.

The State 2 monthly 95th percentile analyses were obtained by

dividing the estimated monthly 95th percentiles of those systems

reporting only daily maximums by a factor of 1.2 to account for bias.

This factor was derived as follows. The daily maximum was determined

for each day in the State 1 data set and a monthly 95th percentile (of

the 30 or 31 daily maximums) was determined, i.e., the second largest

daily maximum. The corresponding monthly 95th percentile based on the

daily data was also determined. The ratio of these two values was then

calculated and summarized across months. The median ratio across all

months was 1.2, with 90 percent of the ratios ranging between 1.0 and

1.9. The analysis used to derive the adjustment factor examined only

plants that reported six values per day.

The remaining data set included in the turbidity analysis was of

plants participating in the Partnership for Safe Water. The Partnership

for Safe Water is a joint venture of several organizations, including

the American Water Works Association, the Association of State Drinking

Water Administrators, the Association of Metropolitan Water Agencies,

the National Association of Water Companies, the American Water Works

Association Research Foundation and USEPA. These organizations

[[Page 59500]]

entered into a voluntary ``partnership'' with the nation's drinking

water filtration plants treating surface water to tighten treatment

practices and operational controls to reduce the risk from

Cryptosporidium and other waterborne pathogens. The Partnership

approach, described in the ``Partnership for Safe Water Voluntary Water

Treatment Plant Performance Improvement Program Self-Assessment

Procedures'' (USEPA et al. 1995), is based on USEPA's Composite

Correction Program (CCP). The CCP is a voluntary program which is

described in detail in the handbook Optimizing Water Treatment Plant

Performance Using the Composite Correction Program--USEPA/625/6-91/027.

The Partnership for Safe Water utility membership consists of 199

utilities representing almost 280 water treatment plants. These plants

serve approximately 80 million persons. The Partnership consists of

four phases with each phase providing tools and methodologies to assist

utilities in progressing toward a higher quality finished water. The

following data summarizes turbidity performance based on 4-hour

measurements reported by the Partnership utilities for 12 months

overlapping 1995 and 1996. The data represents a composite of

Partnership utilities that have completed varying phases of Partnership

activities, ranging from having just joined to having progressed well

into the self-assessment phase (phase 3). All data were derived from

the 1997 Partnership for Safe Water Annual report (Bissonette, 1997).

The results of the analyses of all of the data sets are shown in

Tables 3 and 4.

Tables 3 and 4 indicate the extent to which plants, as currently

operated, are meeting different turbidity levels. Conversely the data

indicate the portion of utilities which might need to alter existing

practice in order to meet lower turbidity limits, if such limits were

required through regulation.

Table 3 is organized to reflect the extent to which utilities are

currently meeting monthly 95th percentile turbidity limits, assuming

that compliance with such limits is determined as currently done under

the existing monthly 95th percentile standard of 10,000. State 1 (4-hour daily data from 47 plants): 10 CA, 10 OR, 9 TX, 6 WI, 6 WV,

6 WY. State 2 (86 plants including State 1 data and daily maximums * from additional plants) : 10 CA, 5 GA, 9

KS, 5 NJ, 12 OH, 10 OR, 6 RI, 9 TX, 8 WI, 6 WV, 6 WY. AWWSC: 45 plants: 1 CA, 3 CT, 2 IA, 6 IN, 1 MD, 2 MO, 24

PA, 1 TN, 2 VA, 3 WV. Partnership for Safe Water 235 plants. *For plants with only daily maximums, the monthly

95th percentile was estimated as the 95th percentile of the daily maximums divided by 1.2. The adjustment was

done to account for the potential bias of taking the 95th percentile of daily maximums, and was based on the

relationship observed in the State 1 data between the 95th percentile of the daily maximums and the 95th

percentile of the 4-hour data.

Table 4.--Number and Percent of Plants That Exceeded Monthly Maximum Turbidity Limits in at Least N Months out

of 12

----------------------------------------------------------------------------------------------------------------

At least 1 month At least 3 months At least 6 months

Maximum turbidity limit Data source -----------------------------------------------------------------

Num Pct Num Pct Num Pct

----------------------------------------------------------------------------------------------------------------

0.3.......................... State 1........ 36 76.6 15 31.9 6 12.8

State 2 69............. 80.2 36 41.9 15 7.4

AWWSC 24............. 53.3 10 22.2 4 8.9

Partnership 129............ 54.9 72 30.6 37 15.7

0.5.......................... State 1........ 18 38.3 3 6.4 1 2.1

State 2 35............. 40.7 7 8.1 1 1.2

AWWSC 12............. 26.7 3 6.7 0 0.0

Partnership 65............. 27.7 20 8.5 5 2.1

1.0.......................... State 1........ 1 2.1 0 0.0 0 0.0

State 2 6.............. 7.0 0 0.0 0 0.0

AWWSC 4.............. 8.9 0 0.0 0 0.0

Partnership 16............. 6.8 4 1.7 2 0.9

2.0.......................... State 1........ 1 2.1 0 0.0 0 0.0

State 2 2.............. 2.3 0 0.0 0 0.0

AWWSC 0.............. 0.0 0 0.0 0 0.0

Partnership 7.............. 3.0 2 0.9 1 0.4

----------------------------------------------------------------------------------------------------------------

b. Individual Filter Performance.

During a turbidity spike, significant amounts of particulate matter

(including oocysts, if present) may pass through the filter. Figure 3

presents the turbidity levels over time of a typical filter. The

greatest potential for a peak (and thus, pathogen break-through) is

near the beginning of the filter run after filtered backwash or start

up of operation (Amirtharajah 1988; Bucklin et al. 1988; Cleasby 1990;

and Hall and Croll 1996).

Various factors effect the duration and amplitude of filter spikes,

including sudden changes to the flow rate through the filter, treatment

of the filter backwash water, filter to waste capability, and site-

specific water quality conditions. The M-DBP Advisory Committee also

discussed the need to control turbidity spikes in order to limit the

number of oocysts passing through the filter.

BILLING CODE 6560-50-P

[[Page 59502]]

[GRAPHIC] [TIFF OMITTED] TP03NO97.045

BILLING CODE 6560-50-C

c. Turbidity Measurement.

Turbidity is a measure of light scatter that is affected by the

size distribution and shape of suspended particles in the water. Four

methods are commonly used to measure turbidity and all are approved for

use under the SWTR. They include the Nephelometric Method listed in

2130B of the Standard Methods for the Examination of Water and

Wastewater, Standard Test Method for Turbidity of Water ASTM (1990)

D1889-94, the Nephelometric Method in 180.1 of USEPA-600/R-93-100 and

the Great Lakes Instruments Method 2 (see section 141.74(a)(1)).

Turbidimeters which measure turbidity commonly consist of the

following components: (1) a light source and lenses and other optical

devices to project the light beam at the sample container and to direct

the scattered light to the detector; (2) a transparent cell that

contains the water to be measured; (3) light traps within the sample

chamber that minimize the amount of stray light that reaches the

detector; and (4) a meter that indicates the intensity of the light

reaching the detector. While turbidity measurement has long been

recognized as a means for evaluating treatment performance for removal

of particulate matter (which include microorganisms), issues remain

pertinent to the accuracy and precision of the measurement (Hart et al.

1992; Sethi et al. 1997).

Large tolerances in instrument design criteria, intended to promote

competition among instrument manufacturers, have lead to turbidimeters

with significantly different design features being available on the

market. Turbidimeters with different designs (but within the design

specifications of Standard Methods), calibrated according to

manufacturer's recommendations, have been shown to provide different

turbidity readings for a given suspension (Hart et al. 1992). The

significance of this phenomenon as it might pertain to the same water

with changing turbidities over time or different waters in the U.S. is

not known. Therefore, narrowing instrument design criteria could reduce

variation of turbidity measurement but the best direction that such

change should take is not yet apparent.

Calibration procedures also affect turbidity measurements.

Calibration typically involves placing a quantity of a standard

suspension in the turbidimeter and then adjusting the response so that

the meter gives a reading equal to the turbidity value assigned to the

standard. Instruments that are calibrated with currently approved

different standard suspensions can yield different turbidity

measurements on the same water (Hart et al. 1992). The significance of

this phenomenon as it might pertain to the same water with changing

turbidities over time or different waters in the U.S. is also not

known. While narrowing specifications for current calibration

procedures could reduce variation of turbidity measurements, the best

direction that such change should take is not yet apparent.

Other factors that may affect turbidity measurement include

procedures used to prepare and wipe the sample cell and use of sample

degassing procedures. The extent to which all of the above factors,

collectively, affect turbidity measurement is not known. However, past

performance evaluation (PE) studies conducted by USEPA provide some

indication of accuracy and precision of turbidity measurements among

different laboratories for a common synthetically prepared water. In PE

studies, PE samples with known turbidity levels are sent to

participating laboratories (who are not informed of the turbidity

level). Laboratories participating in these studies used turbidimeters

from various manufacturers and conducted their analysis in accordance

with calibration and analytical procedures they are familiar with.

Thus, the variability of the results reflect differences resulting from

using different turbidimeter models and methods and the effects of

different laboratory procedures. Table 5 summarizes results from PE

studies conducted at turbidity levels close to the SWTR turbidity

performance limit of 0.5 NTU. The Relative Standard Deviation (RSD) is

the Standard Deviation divided by the mean. It appears that the RSD at

turbidity levels considered in these PE studies are slightly below 20%.

(A RSD of 20% implies that 95% of one-time turbidity measurements made

by different laboratories would fall within 40% of the mean. The RSD

for an individual laboratory, making numerous measurements on a given

sample water would be expected to be significantly less than that

achieved among different laboratories (using a variety of turbidimeters

as indicated in Table 5).

[[Page 59503]]

Table 5.--USEPA Performance Evaluation Results of Turbidity Measurements (USEPA 1997d)

[Turbidity readings are expressed in NTU, and Relative Standard Deviation in %]

----------------------------------------------------------------------------------------------------------------

No. of Relative S

Study No. True Turb. samples Mean D

----------------------------------------------------------------------------------------------------------------

34 USEPA/State............................................. .720 54 .752 16.0

34 All Lab................................................. .720 1503 .744 15.8

23 USEPA/State............................................. .650 24 .659 10.1

25 USEPA/State............................................. .600 28 .585 13.8

25 All Lab................................................. .600 708 .597 16.0

25 USEPA/State............................................. .450 29 .463 20.5

25 All Lab................................................. .450 707 .481 19.5

22 USEPA/State............................................. .350 52 .406 16.1

----------------------------------------------------------------------------------------------------------------

No data is yet available on measurement performance from PE studies

at levels less than 0.3 NTU. A major concern expressed by participants

among the Advisory Committee is the ability to reliably measure low

turbidity levels. The TWG assumed that if systems operated to achieve a

turbidity limit of less than 0.2 NTU 95 percent of the time, this would

provide an adequate margin of safety from variability in treatment

performance and turbidity measurement error, to consistently meet a

turbidity limit of 0.3 NTU.

USEPA intends to conduct two PE studies with true turbidities

ranging from 0.1 to 0.3 NTU. One study is planned to begin no later

than the end of January 1998 and the other study within 6 months

thereafter. These new studies will provide an indication of accuracy

and precision of turbidity measurements at lower levels than previously

examined. Measurements by on-line turbidimeters will also be evaluated.

On-line monitoring issues: For expedience, on-line turbidimeters

are often calibrated against a bench instrument that has been

accurately calibrated by comparing the turbidity level in a water

sample. However, at regular intervals they need to be taken off line

and calibrated, as for bench instruments, by pouring the prepared

standard suspension into the chamber of the instrument. On-line

instruments must be inspected regularly to remove air bubbles and

accumulated debris. Fluctuations in continuous measurements do not

necessarily signify a decrease in water treatment performance.

Fluctuations in continuous measurements should be investigated since

they may be due to air bubbles, debris or a temporary disturbance due

to a change in the flow rate of sample water flow through the

turbidimeter. To address the contingency of such phenomenon, the

Advisory Committee recommended, based on advice from the Technical Work

Group, that turbidity spikes should be defined on the basis of at least

2 consecutive measurements taken over some interval of time (e.g., 15

minutes).

There is no standard design specification for on-line turbidimeters

regarding chamber size and recommended flow rate. Thus, turbidity

spikes of the treated water will be reflected with a delay of a few

seconds to a few minutes, depending on chamber volume and flow rate of

the turbidimeter. A turbidity peak measured by a turbidimeter with a

large chamber volume and small flow rate will result in slightly

reduced peak.

3. Advisory Committee Recommendations and Related Issues

USEPA reiterates its request for comment on the following

recommendations of the M-DBP Advisory Committee.

1. Turbidity Performance Requirements. For all surface water

systems that use conventional treatment or direct filtration, serve

more than 10,000 people, and are required to filter: (a) the

turbidity level of a system's combined filtered water at each plant

must be less than or equal to 0.3 NTU in at least 95 percent of the

measurements taken each month and, (b) the turbidity level of a

system's combined filtered water at each plant must at no time

exceed 1 NTU. For both the maximum and the 95th percentile

requirements, compliance shall be determined based on measurements

of the combined filter effluent at four-hour intervals.

2. Individual Filter Requirements. All surface water systems

that use rapid granular filtration, serve more than 10,000 people,

and are required to filter shall conduct continuous monitoring of

turbidity for each individual filter and shall provide an exceptions

report to the State on a monthly basis. Exceptions reporting shall

include the following: (1) any individual filter with a turbidity

level greater than 1.0 NTU based on 2 consecutive measurements

fifteen minutes apart; and (2) any individual filter with a

turbidity level greater than 0.5 NTU at the end of the first 4 hours

of filter operation based on 2 consecutive measurements fifteen

minutes apart. A filter profile will be produced if no obvious

reason for the abnormal filter performance can be identified.

If an individual filter has turbidity levels greater than 1.0

NTU based on 2 consecutive measurements fifteen minutes apart at any

time in each of 3 consecutive months, the system shall conduct a

self-assessment of the filter utilizing as guidance relevant

portions of guidance issued by the Environmental Protection Agency

for Comprehensive Performance Evaluation (CPE). If an individual

filter has turbidity levels greater than 2.0 NTU based on 2

consecutive measurements fifteen minutes apart at any time in each

of two consecutive months, the system will arrange for the conduct

of a CPE by the State or a third party approved by the State.

3. State Authority: States must have rules or other authority to

require systems to conduct a Composite Correction Program (CCP) and

to assure that systems implement any follow-up recommendations that

result as part of the CCP.

In reference to the above recommendations, EPA also requests

comment on what would or would not constitute an obvious reason for

abnormal filter performance. The Agency also requests comment on how

much time a system should have to conduct a self-assessment of the

filter and how much time a system should have to arrange for the

conduct of a CPE under circumstances such as described in the

recommendations.

USEPA also requests comment on whether there are particular filters

currently in operation in the United States for which specific guidance

may be needed with regard to individual filter monitoring. For example,

some members of the M-DBP Advisory Committee suggested that special

guidance be developed for unique filtration devices made by Infilco

Degremeont (previously made by Aldridge). These devices consist of

multi-celled filters with a traveling bridge-automated back washing

unit that are not conducive to individual cell monitoring.

USEPA also requests comment regarding existing SWTR provisions for

lime softening plants that have very low

[[Page 59504]]

turbidity in source waters. The existing SWTR allows States to set

numerically higher standards up to 1 NTU in 95 percent of samples taken

per month for conventional treatment and direct filtration plants if

the State determines that on-site studies demonstrate at least 99.9

percent overall removal and/or inactivation of Giardia cysts. (54 FR

27503). In the SWTR (54 FR 27486), the Agency notes that actual

demonstrations ``(e.g. with pilot plant study results)'' are not

required for the State to determine when minimum performance

requirements at the higher turbidity level might be appropriate for a

particular system. The SWTR states:

Instead, the State's determination may be based upon an analysis

of existing design and operating conditions (e.g. adequacy of

treatment prior to filtration, percent turbidity removal across the

entire treatment train, stringency of disinfection) and/or

performance relative to certain water quality characteristics (e.g.

microbiological analysis of the filtered water, particle size counts

in water before and after filtration). The State may wish to

consider such factors as source water quality and system size in

determining the extent of analysis necessary. (54 FR 27503).

Committee members raised situations where filtration plants have

been designed for specific source water quality characteristics such as

high alkalinity and extremely low turbidity water (e.g. 0.1 to 0.5

NTU). In systems with such source waters, turbidity levels from the

filters may actually be higher than in the source waters due to

reactions from chemicals added mainly for purposes other than source

water particle removal. Lime softening plants operating under certain

conditions, depending upon process configuration and raw water

characteristics or when flocculation conditions change, may

periodically experience a carry over of extremely fine calcium

carbonate or magnesium hydroxide particles. These fine particles may

pass through filters thereby resulting in artificially elevated

effluent turbidity levels. If turbidity performance criteria are

tightened under the IESWTR some plants may have difficulty meeting

these criteria but still achieve substantial removal of Giardia

lamblia, Cryptosporidium parvum, and viruses. As reflected in the 1989

SWTR, USEPA believes that in cases where lime softening is practiced

and source water turbidity levels are low, provisions for alternative

treatment performance criteria (i.e., in lieu of turbidity) may be

appropriate.

As in the present SWTR, USEPA believes that demonstrations of

equivalent protection need not be based on actual demonstrations (e.g.

pilot plant study results). Instead the State's determination can be

based on the factors cited at 54 FR 27503 as quoted above. Other

factors related to source water microbial quality (e.g. pristine source

water, source water protection programs, microbial monitoring results,

bank filtration) may be appropriate for such determinations.

USEPA requests comment on the appropriateness of continuing

existing provisions that provide States the flexibility of approving

higher turbidity levels up to 1 NTU in 95 percent of samples per month

and up to 2 NTU maximum turbidity for such plants, and additionally

seeks comments on:

What types of plants might fall in this category (e.g.

softening plants designed for color and hardness removal with very

low turbidity source waters);

What demonstrations of equivalent protection from

Giardia lamblia, Cryptosporidium parvum, and viruses are appropriate

(e.g. microbiological analysis of the filtered water, monitoring

results for protozoans, watershed control, wellhead protection

programs);

What additional or alternative requirements States

might place on such systems to insure the objective of equivalent

protection from Giardia lamblia, Cryptosporidium parvum, and viruses

(e.g. regular monitoring for protozoans in source and or filtered

water, or for other water quality parameters, watershed control,

well head protection programs);

Allowing systems to acidify turbidity samples when

calcium carbonate carry-over exists to obtain true turbidity

readings; and

The appropriateness of including source water microbial

quality measurements or surrogates as part of a State determination

of equivalent protection when considering whether to authorize

higher operating turbidity levels.

D. Disinfection Benchmark for Stage 1 DBP MCLS

A fundamental principle of the 1992-93 regulatory negotiation which

was reflected in the 1994 proposal for the IESWTR was that new

standards for control of byproducts must not result in significant

increases in microbial risk. This principle was also one of the

underlying premises of the M-DBP Advisory Committee's deliberations,

i.e., that existing microbial protection must not be significantly

reduced or undercut as a result of systems taking the necessary steps

to comply with the Stage 1 DBPR. The Advisory Committee's

recommendations to meet this key objective are discussed in this

section.

The approach outlined below represents the recommendation of the

Advisory Committee to develop a mechanism that is designed to assure

that pathogen control is maintained while the Stage 1 DBPR provisions

are implemented. Briefly, the disinfection benchmark addresses the

three issues of who must gather the necessary information to evaluate

current practices, how the benchmark operates, and finally, how the

system and the State work together to assure that microbial control is

maintained.

Based on data provided by systems and reviewed by the TWG, the

baseline of microbial inactivation (expressed as logs of Giardia

lamblia inactivation) demonstrated high variability. Inactivation

varied by several logs on a day-to-day basis at any particular

treatment plant and by as much as tens of logs over a year due to

changes in water temperature, flow rate (and consequently contact

time), seasonal changes in residual disinfectant, pH, and disinfectant

demand (and consequently disinfectant residual). There were also

differences between years at individual plants.

To address these variations, the TWG developed an approach for a

system to use to characterize disinfection practice; the procedure is

called profiling. In essence, this approach allows a plant to chart or

plot its daily levels of Giardia inactivation on a graph which, when

viewed on a seasonal or annual basis, represents a ``profile'' of the

plant's inactivation performance. The system can use the profile to

develop a baseline or benchmark of inactivation against which to

measure possible changes in disinfection practice. This approach makes

it possible for a plant that may need to change practice to meet DBP

MCLs to assure no significant increase in microbial risk. It provides

the necessary tool to allow plants to project or measure the possible

impacts of potential changes in disinfection. Only certain systems

would be required to develop a profile and keep it on file for State

review during sanitary surveys, and only a subset of those required to

develop a profile would be required to submit it to the State as part

of a package submitted when the system is making significant changes to

its disinfection practice.

USEPA reiterates its request for comment on the following

recommendations of the M-DBP Advisory Committee that address the three

questions outlined above: (1) who should develop a profile, (2) how a

profile is actually generated, and (3) how the profile will be used.

1. Applicability

Systems would be required to prepare a disinfection profile, if at

least one of the following criteria are met:

[[Page 59505]]

(1) TTHM levels are at least 80% of the MCL (0.064 mg/l) as an

annual average for the most recent 12 month compliance period for

which compliance data are available prior to November 1998 (or some

other period designated by the State). Monitoring would be in

accordance with current TTHM requirements.

(2) Haloacetic acid (HAA5) levels are at least 80% of the MCL

(0.048 mg/l) as an annual average for the most recent 12 month

period for which data are available (or some other period designated

by the State). In connection with HAA5 monitoring, the following

provisions apply:

(a) Systems that have collected HAA5 data under the ICR must use

those data to determine the HAA5 level, unless the State determines

that there is a more representative annual data set.

(b) If the system does not have four quarters of HAA5 data by

the end of 90 days following the IESWTR promulgation date, the PWS

must conduct HAA5 monitoring for four quarters. This monitoring must

comply with the monitoring requirements included in the DBP Stage 1

rule.

(The Advisory Committee recommended a value of 80% of the MCL

because available data indicated that DBP levels varied from year to

year due to many factors (e.g., changes in source water quality,

changes in water demand). The Committee believed that targeting a level

20% below the MCL would include most systems that would be expected to

make changes to comply with the TTHM and HAA5 MCLs on a continuing

basis. Also, USEPA previously considered this target level at the

recommendation of the 1992 reg-neg committee, to evaluate DBP Stage 1

compliance forecasts and costs, based upon the judgement that most

facilities will take additional steps to ensure continuing MCL

compliance if they are at or above these levels.)

2. Developing the Profile and Benchmark

As outlined above, profiling is the characterization of a system's

disinfection practice over a period of time. The system can create the

profile by conducting new daily monitoring or by using

``grandfathered'' data (as explained below). A disinfection profile

consists of a compilation of daily Giardia lamblia log inactivations

(or virus inactivations under conditions to be specified in the final

rule), computed over the period of a year, based on daily measurements

of operational data (disinfectant residual concentration(s), contact

time(s), temperature(s), and where necessary, pH(s)).

Grandfathered data are those operational data that a system

previously collected at a treatment plant during the course of normal

operation. These data may or may not have been used previously for

compliance determinations with the SWTR. Those systems that have all

necessary data to determine profiles, using operational data collected

prior to promulgation of the IESWTR, would be able to use up to three

years of operational data in developing profiles. Grandfathered

operational data should be substantially equivalent to operational data

that would be collected under this rule.

Those systems that do not have three years of operational data to

develop profiles would have to conduct monitoring to develop the

profile for one year beginning no later than 15 months after IESWTR

promulgation. If the PWS has existing operational data to develop

profiles, it would have to use those data to develop profiles for the

years prior to the IESWTR promulgation.

In order to develop the profile, a system would have to:

--Measure disinfectant residual concentration (C, in mg/l) prior to

entrance into distribution system and just prior to each additional

point of disinfectant addition, whether with the same or a different

disinfectant.

--Determine contact time (T, in minutes) during peak flow conditions. T

can be based on either a tracer study or assumptions based on contactor

geometry and baffling. However, systems would have to use the same

method for both grandfathered data and new data.

--Measure water temperature ( deg. C).

--Measure pH (for chlorine only).

The system would then have to convert operational data to log

inactivation values for Giardia (and viruses when chloramines or ozone

used as primary disinfectant).

--Determine CTactual for each disinfection segment.

--Determine CT99.9 (i.e., 3-logs inactivation) from tables

in the SWTR/IESWTR using temperature (and pH for chlorine) for each

disinfection segment. [NOTE: USEPA may redesign the tables so that no

conversion is necessary (i.e., the tables will reflect a

CT90 (1-log) value.]

--For each segment, log inactivation = (CTact/

CT99.9) x 3.0.

A log inactivation benchmark would then be calculated as follows:

1. Calculate the average log inactivation for each calendar month.

2. Determine the calendar month with the lowest average log

inactivation.

3. The lowest average month becomes the critical period for that

year.

4. If data from multiple years are available, the average of

critical periods for each year becomes the benchmark.

5. If only one year of data is available, the critical period for

that year is the benchmark.

3. State Review

The State would review disinfection profiles as part of its

periodic sanitary survey. If a system that is required to develop a

disinfection profile subsequently decides to make a significant change

in disinfection practice, it would have to consult with the State

before implementing such a change. Significant changes would be defined

as: (1) moving the point of disinfection, (2) changing the type of

disinfectant, (3) changing the disinfection process, or (4) making any

other change designated as significant by the State. Supporting

materials for such consultation would have to include a description of

the proposed change, the disinfection profile, and an analysis of how

the proposed change will affect the current disinfection benchmark.

4. Guidance

USEPA, in consultation with interested stakeholders, will develop

guidance for States and systems on how to develop and evaluate

disinfection profiles, how to identify and evaluate significant changes

in disinfection practices, and guidance on moving the point of

disinfection from before the point of coagulant addition to after the

point of coagulant addition. USEPA will also develop guidance for

systems that would be required to develop a profile based on virus

inactivation instead of Giardia lamblia inactivation. Guidance will be

available when the IESWTR is promulgated.

5. Request for Public Comment

USEPA requests comment on all aspects of the recommendation

outlined above and any alternative suggestions that stakeholders or

other interested parties may have. Commenters may want to focus

particular attention on the following issues:

--Applicability requirements,

--Characterization of disinfection practices and components (e.g.,

monitoring, analysis),

--Use of TTHM and HAA5 data from the same time period instead of TTHM

data from one year and HAA5 data from another,

--Definition of significant changes to disinfection practice,

--Different approaches to evaluating possible changes in disinfection

practice against a disinfection profile, and

--Whether the use of grandfathered data, if available, should be

[[Page 59506]]

mandatory for profiling and benchmarking.

E. Definition of Ground Water Under the Direct Influence of Surface

Water (GWUDI)--Inclusion of Cryptosporidium in the Definition

1. Summary of 1994 Proposal and Public Comments

The July 29, 1994, Federal Register notice proposed to amend the

SWTR by including Cryptosporidium in the definition of a GWUDI system.

Under the rule, a system using ground water considered vulnerable to

Cryptosporidium contamination would be subject to the provisions of the

SWTR. USEPA proposed that this determination be made by the State for

individual sources using State-established criteria.

The 1994 proposed IESWTR also requested comment on revisions to

USEPA's guidance on this issue. Cryptosporidium oocysts are smaller

than Giardia cysts and may have substantially different hydrodynamic

behavior in ground water due to their smaller size and perhaps also due

to a difference in charge distribution on the outer surface of the

oocyst. USEPA guidance for the determination of GWUDI suggests methods

that may be insensitive to this differing hydrodynamic behavior in

ground water.

Almost all commenters agreed that Cryptosporidium should be added

to the definition. Only one commenter clearly opposed the addition

without caveat, maintaining that problems with the analytical methods

for the recovery and enumeration of viable organisms and uncertainties

associated with risk assessment should preclude its addition. One

commenter contended that Cryptosporidium should be included only if

USEPA addresses the amount of natural disinfection at each site and

defines treatment effectiveness, especially coagulant use, for GWUDI

systems. One commenter believed that the definition of Cryptosporidium

should be made at the species level, e.g. Cryptosporidium parvum,

because other species were not pathogenic to humans.

One commenter was concerned about the Microscopic Particulate

Analysis (MPA), one of the methods that USEPA identifies in guidance as

being suitable for making GWUDI determinations. As part of this method,

a microscopic examination is made of the ground water to determine

whether insect parts, plant debris, rotifers, nematodes, Giardia

lamblia, and other material associated with the surface or near surface

environment are present. The commenter claimed that the MPA has

analytical method problems similar to those associated with the

recovery of cysts and oocysts from environmental samples and suggested

that the method should undergo additional testing with positive and

negative controls and with performance evaluation samples.

2. Overview of Existing Guidance

USEPA issued guidance on the MPA in October 1992 as the Consensus

Method for Determining Groundwater Under the Direct Influence of

Surface Water Using Microscopic Particulate Analysis. Additional

guidance for making GWUDI determinations is also available (USEPA,

1994e,f). Since 1990, States have acquired substantial experience in

making GWUDI determinations and have documented their approaches

(Massachusetts Department of Environmental Protection, 1993; Maryland,

1993; Sonoma County Water Agency, 1991). Guidance on existing practices

undertaken by States in response to the SWTR may also be found in the

State Sanitary Survey Resource Directory, jointly published in December

1995 by USEPA and the Association of State Drinking Water

Administrators. AWWARF has also published guidance (Wilson et al.,

1996).

3. Summary of New Data and Perspectives

Most recently, Hancock et al. (1997) used the MPA test to study the

occurrence of Giardia and Cryptosporidium in the subsurface. They found

that, in a study of 383 ground water samples, the presence of Giardia

correlated with the presence of Cryptosporidium. The presence of both

pathogens correlated with the amount of sample examined but not with

the month of sampling. There was a correlation between source depth and

occurrence of Giardia but not Cryptosporidium. The investigators also

found no correlation between the distance of the ground water source

from adjacent surface water and the occurrence of either Giardia or

Cryptosporidium. However, they did find a correlation between distance

from a surface water source and generalized MPA risk ratings of high

(high represents an MPA score of 20 or greater), medium or low, but no

correlation was found with the specific numerical values that are

calculated by the MPA scoring system.

USEPA is interested in an expanded discussion of MPA performance.

The work cited here is preliminary information and represents the only

data provided to USEPA so far. USEPA is considering several analytical

activities to address possible changes in the GWUDI determination

guidance. These changes are as follows:

Change the MPA methodology to include a score for

Cryptosporidium oocysts in the risk rating method.

Conduct additional comparison of MPA scores with cyst and

oocyst recovery to evaluate the performance of MPA as an indicator

method (e.g., Schulmeyer, 1995).

Conduct additional MPA performance evaluation testing

(with both positive and negative controls).

Compare MPA scores and cyst/oocyst recovery in horizontal

collector wells and vertical wells to determine if additional guidance

for horizontal collector wells is needed.

4. Request for Public Comment

USEPA is continuing to consider inclusion of Cryptosporidium in the

definition of GWUDI. USEPA requests further comment on this issue as

well as on issues outlined above pertaining to guidance for GWUDI

determinations.

F. Inclusion of Cryptosporidium in Watershed Control Requirements

1. Summary of 1994 Proposal and Public Comments

USEPA proposed to extend the existing watershed control

requirements for unfiltered systems to include the control of

Cryptosporidium. This would be analogous to and build upon the existing

requirements for Giardia lamblia and viruses; Cryptosporidium would be

included in the watershed control provisions wherever Giardia lamblia

is mentioned. USEPA also proposed requiring a State, as a condition of

primacy, to describe how it would judge the adequacy of watershed

control programs for Cryptosporidium as well as Giardia lamblia and

viruses in the source water.

Several commenters to the proposed rule specifically supported

inclusion of Cryptosporidium in watershed control. Others supported

watershed control programs in general without specifically articulating

an opinion on Cryptosporidium. One commenter specifically opposed the

inclusion of Cryptosporidium in watershed control program, maintaining

that other avenues of watershed control could be promoted without

including this organism in the control plan. Another commenter opposed

including Cryptosporidium because environmental sources of Giardia and

Cryptosporidium were not sufficiently understood. This commenter also

opposed the requirement to include Cryptosporidium

[[Page 59507]]

in State watershed control program protocols as a condition of primacy.

Other comments included: (1) Systems need to be informed of the

nature of upstream pathogen sources and changes in upstream water

quality in a timely manner, (2) watershed characteristics should not be

the sole basis for determining water treatment strategies, (3) upstream

sewage discharges should be prohibited and cattle farming and feedlots

prohibited or substantially limited in a watershed, and (4) watershed

control programs should be scientifically based, educational, and

voluntary. One commenter contended that the burden of contamination on

the watershed should not fall to the drinking water systems, and that

better coordination on regulations is needed between the USEPA's

drinking water and wastewater programs.

2. Overview of Existing Guidance

The SWTR specifies the conditions under which a system can avoid

filtration (40 CFR 141.71). These conditions include good source water

quality, as measured by concentrations of coliforms and turbidity,

disinfection requirements; watershed control; periodic on-site

inspections; the absence of waterborne disease outbreaks; and

compliance with the Total Coliform Rule and the MCL for TTHMs.

The watershed control program under the SWTR must minimize the

potential for source water contamination by Giardia lamblia and

viruses. This program must include a characterization of the watershed

hydrology characteristics, land ownership and activities which may have

an adverse effect on source water quality. The SWTR Guidance Manual

(USEPA, 1991a) identifies both natural and human-caused sources of

contamination to be controlled. These sources include wild animal

populations, wastewater treatment plants, grazing animals, feedlots,

and recreational activities. The Guidance Manual recommends that

grazing and sewage discharges not be permitted within the watershed of

unfiltered systems, but indicates that these activities may be

permissible on a case-by-case basis where there is a long detention

time and a high degree of dilution between the point of activity and

the water intake.

3. Summary of New Data and Perspectives

Since proposal of the IESWTR in July 1994, several new outbreaks of

waterborne cryptosporidiosis have occurred in the United States. A

recent summary of these outbreaks (Solo-Gabriele and Neumeister, 1996)

identified raw sewage, surface runoff from livestock grazing areas,

septic tank effluent, cattle wastes, treated wastewater, and backflow

of contaminated water in the distribution system as the suspected

sources of Cryptosporidium contamination of the water supplies in these

outbreaks. Cattle grazing, feedstocks and in particular, calves and

other young livestock, appear to be of greater concern for

Cryptosporidium contamination than for Giardia. Some outbreaks of

cryptosporidiosis have been related to upsets in the treatment process

of filtered water systems or have occurred on occasions when spikes in

turbidity have occurred in those systems. However, little information

is available for unfiltered water systems as to whether spikes in raw

water turbidity increase the likelihood that elevated levels of

Cryptosporidium are present in the source water. Because

Cryptosporidium cannot easily be controlled with conventional

disinfection practices, there is particular concern about the presence

of this organism in the source waters of systems that do not filter.

Data from the ICR may be useful in providing information on the

relative Giardia and Cryptosporidium levels in the raw water sources of

unfiltered and filtered water systems. In one comprehensive study on

Giardia and Cryptosporidium densities in ambient water and drinking

water, investigators (LeChevallier and Norton, 1995) found

Cryptosporidium oocyst levels in ambient water ranging from 0.065/L to

65.1/L, with a geometric mean of 2.4 oocysts/L. In drinking water, the

level of Cryptosporidium oocysts ranged from 0.29-57 oocysts/100L, with

a mean of 3.3 oocysts/100L.

The Seattle Water Department summarized the Giardia and

Cryptosporidium monitoring results from several unfiltered water

systems (Montgomery Watson, 1995). The central tendency of this data is

about 1 oocyst/100L. Thus, depending upon what removal efficiencies are

achieved by filtration for Cryptosporidium (for example, 2 logs), it

appears that unfiltered water systems that comply with the source water

requirements of the SWTR may have a risk of cryptosporidiosis

equivalent to that of a water system with a well-operated filter plant

using a water source of average quality.

Although there are no specific monitoring requirements in the

watershed protection program, the non-filtering utility is required to

develop state-approved techniques to eliminate or minimize the impact

of identified point and non-point sources of pathogenic contamination.

USEPA is considering adding specific monitoring requirements to the

IESWTR for the unfiltered supplies serving 10,000 or more people to

ensure the continued effectiveness of the watershed control program.

The monitoring would be similar to the requirements under the ICR for

Giardia and Cryptosporidium although the sampling frequency may be

modified. As with the ICR, a USEPA-approved method and laboratory for

Giardia and Cryptosporidium analyses would be required.

At a minimum, such a monitoring program might require some level of

routine sampling (e.g., on a weekly, biweekly or monthly basis). The

program may also include ``event'' sampling. An ``event'' would

constitute an occasion when the raw water turbidity and/or fecal/total

coliform concentration exceeded a specific value or possibly exceeded a

site-specific 90th percentile value. At least one sample during an

event might be required in addition to routine sampling. Results of all

protozoa and related analyses would be made available to the State at a

minimum as part of the annual on-site inspection required under the

SWTR for non-filtering supplies.

USEPA is continuing to consider extending the existing watershed

control requirements for unfiltered systems to include the control of

Cryptosporidium. USEPA requests further comment on this issue. The

Agency also requests comment on issues pertaining to monitoring for

unfiltered systems serving 10,000 or more people, including comment on

the following approaches:

Routine Source Water Giardia and Cryptosporidium Monitoring:

Option 1. Weekly Giardia and Cryptosporidium Monitoring

Option 2. Bi-Weekly Giardia and Cryptosporidium Monitoring

Option 3. Monthly Giardia and Cryptosporidium Monitoring

The Agency also requests comments on whether the frequency of

monitoring should depend on system size, e.g., should requirements

differ for systems serving between 10-100,000 people versus those

serving more than 100,000 people.

``Event'' Source Water Giardia and Cryptosporidium Monitoring:

Option 1. No event sampling required.

Option 2. Collect sample(s) for Giardia and Cryptosporidium when

source water turbidity exceeds 1.0 NTU or some alternative value such

as a site-

[[Page 59508]]

specific 90th percentile which might be lower than 1.0 NTU.

Option 3. Collect sample(s) for Giardia and Cryptosporidium when

source water fecal coliform concentration exceeds 20 per 100 mL or

total coliform level exceeds 100 per 100 mL, depending on which class

of coliforms is used under the individual systems filtration avoidance

agreement. Alternatively, the trigger could be some other coliform or

fecal coliform value.

Option 4. Individual utility develops turbidity frequency

distribution (e.g., based on previous 1 to 3 years of daily historical

data) and collects sample(s) for Giardia and Cryptosporidium when

turbidity exceeds 90th percentile level.

Option 5. Some combination of Options 2, 3, or 4.

The Agency also requests comment on whether any of the above

options should depend on system size.

G. Sanitary Survey Requirements

1. Summary of 1994 Proposal and Public Comments

The July 29, 1994, Federal Register proposed to amend the SWTR to

require periodic sanitary surveys for all public water systems that use

surface water, or ground water under the direct influence of surface

water, regardless of whether they filter or not. States would be

required to review the results of each sanitary survey to determine

whether the existing monitoring and treatment practices for that system

are adequate, and if not, what corrective measures are needed to

provide adequate drinking water quality.

The July 1994 notice proposed that only the State or an agent

approved by the State would be able to conduct the required sanitary

survey, except in the unusual case where a State has not yet

implemented this requirement, i.e., the State had neither performed the

required sanitary survey nor generated a list of approved agents. The

proposal suggested that under exceptional circumstances the sanitary

survey could be conducted by the public water system with a report

submitted to the State within 90 days. USEPA also requested comment on

whether sanitary surveys should be required every three or every five

years.

Most commenters on this issue voiced support for requiring a

periodic sanitary survey for all systems. One commenter suggested that

USEPA develop sanitary survey guidance for administration by the

States, while another commenter suggested that sanitary surveys by the

private sector be certified by States or national associations using

USEPA-defined criteria. Commenters recommended that surveys be

conducted either by the State or a private independent party/

contractor. One respondent contended that sanitary surveys, as

presently conducted, were insufficient to assess operational

effectiveness in surface water systems.

With regard to sanitary survey frequency, commenters were nearly

evenly divided between every three years and every five years. Some

commenters argued that the frequency should depend on: (1) whether a

system's control is effective or marginal, (2) system size (less

frequent for small systems), (3) source water quality, (4) whether the

State believes a system's water quality is likely to change over time,

(5) results of the previous survey, and (6) population density on the

watershed. One commenter suggested an annual sanitary survey.

Regarding criteria for sanitary survey inspectors, some commenters

suggested that the State should decide what requirements to use. Others

suggested some combination of education and working experience related

to water plant operations, including (1) professional engineering

certificate and water plant operator license for at least five years,

(2) knowledge of surface water contaminants, source and fate of

contaminants, and both removal capabilities of existing treatment

technologies and ability to evaluate their performance, (3) a BS degree

(preferably MS degree) in sanitary or environmental engineering with

two years experience in evaluating water treatment plants and valid

plant operator's license, (4) five years experience in water system

operation, evaluation, and/or design, and a BS in engineering or

environmental science, (5) a BS degree in science or engineering and

five years experience in the drinking water field.

2. Overview of Existing Regulations and Guidance

Sanitary surveys have historically been conducted by state drinking

water programs as a preventive tool to identify water system

deficiencies that could pose a threat to public health. The first

regulatory requirement for systems to have a periodic on-site sanitary

survey appeared in the final TCR (54 FR 27544-27568). This rule

requires all systems that collect less than 5 total coliform samples

each month to undergo such surveys. These sanitary surveys must be

conducted by the State or an agent approved by the State. Community

water systems were to have had the first sanitary survey conducted by

June 29, 1994, and every five years thereafter while non-community

water systems are to have the first sanitary survey conducted by June

29, 1999, and every five years thereafter unless the system is served

by a protected and disinfected ground water supply, in which case, a

survey must be conducted every 10 years.

The SWTR did not specifically require water systems to undergo a

sanitary survey. Instead, it required that unfiltered water systems, as

one criterion to remain unfiltered, have an annual on-site inspection

to assess the system's watershed control program and disinfection

treatment process. The on-site survey must be conducted by the State or

a party approved by the state. This on-site survey is not a substitute

for a more comprehensive sanitary survey, but the information can be

used to supplement a full sanitary survey.

USEPA's SWTR Guidance Manual (USEPA, 1991a), Appendix K, suggests

that, in addition to the annual on-site inspection, a sanitary survey

be conducted every three to five years by both filtered and unfiltered

systems. This time period is suggested ``since the time and effort

needed to conduct the comprehensive survey makes it impractical for it

to be conducted annually.''

3. New Developments

Since the publication of the proposed ESWTR in 1994, USEPA and the

States (through the Association of State Drinking Water Authorities)

have issued a joint guidance on sanitary surveys entitled USEPA/State

Joint Guidance on Sanitary Surveys (1995). The Guidance outlines the

following elements as integral components of a comprehensive sanitary

survey:

Source

--Protection

--Physical Components and Condition

Treatment

Distribution System

Finished Water Storage

Pumps/Pump Facilities and Controls

Monitoring/Reporting/Data Verification

Water System Management/Operations

Operator Compliance with State Requirements

The guidance also addresses the qualifications for sanitary survey

inspectors, the development of assessment criteria, documentation,

follow-up after the survey, tracking and enforcement.

USEPA is aware that a number of States have independently developed

their own sanitary survey criteria. For instance, the American Water

Works Association California-Nevada Section,

[[Page 59509]]

Source Water Quality Committee in conjunction with the California

Department of Health Services, Division of Drinking Water and

Environmental Management (DHS) have published a document entitled

Watershed Sanitary Survey Guidance Manual (AWWA California -Nevada

Section 1993) to assist domestic water suppliers in defining the scope

of their watershed sanitary surveys and to provide information on the

methods and sources of information for conducting sanitary surveys.

4. Advisory Committee Recommendations and Related Issues

USEPA reiterates its request for comment on the following

recommendations of the M-DBP Advisory Committee.

A sanitary survey would be defined as an onsite review of the

water source (identifying sources of contamination using results of

source water assessments where available), facilities, equipment,

operation, maintenance, and monitoring compliance of a system to

evaluate the adequacy of the system, its sources and operations and

the distribution of safe drinking water. Included in this definition

is the concept that components of a sanitary survey may be completed

as part of a staged or phased State review process within the

established frequency interval set forth below. Finally, for a

sanitary survey to fall within this definition, it must address each

of the eight elements in the December 1995 USEPA/State Guidance on

Sanitary Surveys.

In terms of frequency, this approach would provide that sanitary

surveys must be conducted for all surface water systems (including

ground water under the influence) no less frequently than every

three years for community systems and no less frequently than every

five years for noncommunity systems. Any sanitary survey conducted

after December 1995, that addresses the eight sanitary survey

components of the 1995 EPA/State guidance, may be counted or

``grandfathered'' for purposes of completing the round of surveys.

This approach would also provide that for community systems

determined by the State to have outstanding performance based on

prior sanitary surveys, successive sanitary surveys may be conducted

no less than every five years.

Finally, under this approach, as part of follow-up activity for

sanitary surveys, systems must respond to deficiencies outlined in

the State's sanitary survey report within 45 days, indicating how

and on what schedule the system will address significant

deficiencies noted in the survey. In addition, States must have the

appropriate rules or other authority to assure that facilities take

the steps necessary to address significant deficiencies identified

in the survey report that are within the control of the PWS and its

governing body.

USEPA also requests comment on whether systems should be required

to respond in writing to a State's sanitary survey report discussed in

the paragraph above. USEPA also requests comment on (1) what would

constitute ``outstanding performance'' for purposes of allowing

sanitary surveys for a community water system to be conducted every

five years and (2) how to define ``significant deficiencies.''

H. Covered Finished Water Reservoirs

1. Summary of the 1994 Proposal and Public Comments Received

The July 29, 1994, Federal Register indicated that USEPA was

considering whether to issue regulations requiring systems to cover

finished water reservoirs and storage tanks, and requested public

comment. The rationale for this position was given in the proposed

rule.

Most commenters supported either federal or State requirements.

Some commenters suggested that regulations apply only to new

reservoirs. Some commenters opposed any requirement, citing high cost,

the notion that ``one size does not fit all'', and aesthetic benefits

of an open reservoir.

Some commenters suggested elements for such regulations or

guidance, including (1) applying the same criteria to finished water

reservoirs as exists for unfiltered surface water systems, (2) using

engineering measures to minimize contamination, (3) disinfecting the

effluent to maintain residual in distribution system, (4) monitoring

reservoirs routinely for water quality indicators, (5) covering all

storage tanks, (6) fencing reservoirs with signs warning against

swimming, trespassing, and tampering, and (7) adding notices in the

annual water quality report that the reservoir is not in compliance

with current waterworks standards. A few commenters suggested a number

of other elements.

2. Overview of Existing Information

Possible Health Concerns: When a finished water reservoir is open

to the atmosphere it may be subject to some of the environmental

factors that surface water is subject to, depending upon site-specific

characteristics and the extent of protection provided. It may be

subject to contamination by persons tossing items into the reservoir or

illegal swimming (Pluntze 1974; Erb, 1989).

Microscopic and other organisms may proliferate in open finished

water reservoirs. Increases in algal cells, heterotrophic plate count

(HPC) bacteria, turbidity, color, particle counts, biomass and

decreases in chlorine residuals have been reported (Pluntze, 1974, AWWA

Committee Report, 1983, Silverman et al., 1983, LeChevallier et al.

1997a).

Small mammals, birds, fish, and the growth of algae may contribute

to the microbial degradation of an open finished water reservoir

(Graczyk et al., 1996; Geldreich, 1990; Fayer and Ungar, 1986; Current,

1986). Mammals, birds and fish and their carcasses seed the water and

the sediment with total and fecal coliforms, E. coli and pathogens. In

one study, sea gulls contaminated a 10 million gallon reservoir and

increased bacteriological growth and in another study waterfowl were

found to elevate coliform levels in small recreational lakes by twenty

times their normal levels (Morra, 1979). Seagulls are a source of

numerous coliforms and can also be a source for several human

pathogens, (Geldreich and Shaw, 1993). Algal growth increases the

biomass in the reservoir, which reduces dissolved oxygen and thereby

increases the release of iron, manganese, and nutrients from the

sediments. This, in turn, supports more growth (Cooke and Carlson,

1989). Plants, macrophytes and organic debris will add to the biomass

and nutrient supply.

State Regulations: In order to assess regulatory requirements at

the State level, it is necessary to contact individual drinking water

programs and collect and evaluate specific regulatory language obtained

from those programs. A survey of nine States was conducted in the

summer of 1996 (Montgomery Watson, 1996). The States which were

surveyed included several in the West (Oregon, Washington, California,

Idaho, Arizona, and Utah), two States in the East known to have water

systems with open reservoirs (New York and New Jersey), and one

midwestern state (Wisconsin). Seven of the nine States which were

surveyed require by direct rule that all new finished water reservoirs

and tanks be covered.

Survey of Ten Utilities: There is no comprehensive information

available on the number or size of open finished water reservoirs in

water systems around the country; however, there is one recent survey

of ten utilities which either have open finished water reservoirs or

which had them in the past and covered or replaced them (E&S

Environmental Chemistry, 1997). The existing open reservoirs which were

operated by these systems varied greatly in size, from 5.5 million

gallons (MG) to 900 MG. The systems with open finished reservoirs also

had closed reservoirs within their service area, but for some of the

systems the open reservoirs represent the largest component of total

storage volume in the systems.

[[Page 59510]]

Most of the reservoirs in the systems in this survey were excavated

and lined, but several of the larger ones were formed by dams or

natural lakes that had been converted to water supply use. Many of

these reservoirs have irregular geometry and configurations which make

covering very difficult or impossible. Others are so large that

covering them would be impractical. For some of these reservoirs, it is

impractical to find locations for replacement with the proper hydraulic

characteristics and size. To partially solve this problem in some

cases, systems have chosen to leave large existing open reservoirs off-

line, except for emergency supply purposes.

None of the systems had comprehensive evidence about the effect of

open reservoirs on water quality. These water systems had instituted a

number of measures at open reservoirs to control potential sources of

contamination; these measures included fencing setbacks, security

cameras, on-site surveillance, rechlorination, wire canopies to control

bird activity, and other measures.

3. Request for Public Comment

USEPA is considering as part of the IESWTR a requirement that

systems cover all new reservoirs, holding tanks or other storage

facilities for finished water for which construction begins after the

effective date of the rule. The Agency intends to further consider this

issue, including whether there should be a requirement that all

finished water reservoirs, holding tanks and other storage facilities

be covered, as part of the development of the Long-Term ESWTR. The

Agency requests further comment on this issue and whether provisions

should be established to require all new reservoirs, holding tanks, or

other storage facilities to be covered.

I. Cross Connection Control Program

1. Summary of 1994 Proposal and Public Comments

The July 29, 1994, Federal Register requested public comment on

whether the Agency should require States and/or systems to have a

cross-connection control program. In addition, the Agency solicited

comment on a number of associated issues, including (1) what specific

criteria, if any, should be included in such a requirement, (2) how

often such a program should be evaluated, (3) whether USEPA should

limit any requirement to only those connections identified as a cross

connection by the public water system or the State, and (4) conditions

under which a waiver from this requirement would be appropriate. The

Agency also requested commenters to identify other regulatory measures

USEPA should consider to prevent contamination of drinking water in the

distribution system (e.g., minimum pressure requirements in the

distribution system).

Most commenters supported either a federal or State cross

connection control program. Various commenters recommended that such a

program include a backflow prevention program with approved backflow

preventer lists, categorization of all service connections with respect

to potential risk of backflow, requirement for periodic testing and

maintenance of backflow prevention devices, periodic review of program

by State, establishment of an annual backflow device testing program,

establishment of a backflow device inspector certification program,

enforcement authority, and other suggestions. Commenters also

recommended national disinfection procedures for repair of water lines

and for placing new lines into service, a provision for at least one

person trained in cross-connection control to carry out the program,

and other suggestions.

Commenters opposed to a cross connection control program indicated

that (1) a federally-mandated program would be impractical, burdensome,

and would fail, (2) a State program would be more appropriate than an

USEPA-mandated program, (3) most States already have a comprehensive

program, thus negating need for federal regulations, (4) USEPA should

publish general guidelines only, and (5) there should be a separate

regulation because a cross connection control program would affect both

surface water and ground water.

2. Overview of Existing Information

Historically, a significant portion of waterborne disease outbreaks

reported by CDC are caused by distribution system deficiencies.

Distribution system deficiencies are defined in CDC's publication

Morbidity and Mortality Weekly Report as cross connections,

contamination of water mains during construction or repair, and

contamination of a storage facility. Between 1971-1994, approximately

53 waterborne disease outbreaks were associated with cross connections

or backsiphonage. Fifty-six outbreaks were associated with other

distribution system deficiencies (Craun, Pers. Comm. 1997b). Some

outbreaks have resulted from water main breaks or repairs.

There is no centralized repository where backflow incidents are

reported or recorded. The vast majority of backflow incidents are

probably not reported. Specific backflow incidents are described in

detail in USEPA's Cross-Connection Control Manual (USEPA, 1989a).

Where cross connections exist, some protection is still afforded to

the distribution system by the maintenance of a positive water pressure

in the system. Adequate maintenance of pressure provides a net movement

of water out through breaks in the distribution pipes and prevents

contaminated water outside of the pipes from entering the drinking

water supply. The loss of pressure in the distribution system, less

than 20 psi, can cause a net movement of water from outside the pipe to

the inside, possibly allowing the introduction of fecal contamination

into the system. This problem is of special concern where wastewater

piping is laid in the same street as the water pipes, creating a

potential threat to public health whenever there is low or no pressure.

Many States have cross connection control programs. A Florida

Department of Environmental Protection survey evaluated cross-

connection control regulations in the 50 states (Florida DEP 1996). The

survey results showed that 29 of the 40 states that responded to the

survey request have programs. The rigor of the programs and the extent

to which they are enforced was not addressed by the survey. An USEPA

report suggests that the responsibility for administration and

enforcement of the State programs is generally at the local level

(USEPA, 1995a).

3. Request for Public Comment

USEPA does not plan to address cross connection control in the

IESWTR. As noted above, many States currently have programs, although

the extent to which these vary is unclear. The Agency does plan to

consider cross connection control issues during the development of the

Long-Term ESWTR, in the context of a broad range of issues related to

distribution systems. USEPA continues to request comments or additional

information related to cross connection control or other distribution

system issues.

J. Recycling Filter Backwash Water and Filtering to Waste

The July 29, 1994, notice requested comment on the extent to which

the ESWTR should address the issue of recycling filter backwash water,

given its potential for increasing the densities of Giardia and

Cryptosporidium on the filters. The 1996 Amendments to the SDWA require

USEPA to promulgate a

[[Page 59511]]

regulation for filter backwash recycling not later than August 2000,

(SDWA 1412(b)(14)).

Most commenters who addressed this issue contended that backwash

water should not be recycled or that, if it is recycled, it should be

treated first. One commenter suggested that this decision should be

based on the pathogen density in the backwash water. Another commenter

suggested that the rule should include criteria for assessing the

extent of backwash recycling, depending on raw water quality, size of

filters, and water volume. Another commenter maintained that this issue

should be left to the State and system. One commenter suggested that

the impacts of recycling needed additional research and that any rule

addressing this issue needed to incorporate the results of the latest

research.

1. Filter Backwash Recycle Configurations

Treatment plants can be configured into several general categories

but the variation within each category is significant.

One aspect of this treatment variation is how recycling of waste

streams from plant processes are handled. Figure 4 shows a general

schematic of a conventional treatment plant and how recycle streams may

be developed and treated. Note that backwash water treatment is carried

out in a miniature coagulation-flocculation-sedimentation treatment

facility. Some utilities are considering microfiltration to replace

these unit processes.

BILLING CODE 6560-50-P

[[Page 59512]]

[GRAPHIC] [TIFF OMITTED] TP03NO97.046

BILLING CODE 6560-50-C

[[Page 59513]]

Figure 5 shows an alternate view for some water treatment

facilities that do not practice treatment of their recycled waste

streams. There is an almost infinite variety between these two

examples. In addition, waste streams can be recycled to many different

points in the treatment train. The most common recycle points are at

the plant influent or rapid mix. However, there are several known

examples of recycle streams being introduced into the treatment process

as late as the filter influent.

BILLING CODE 6560-50-P

[GRAPHIC] [TIFF OMITTED] TP03NO97.047

BILLING CODE 6560-50-C

Figure 6 shows a typical plot of turbidity over time from a filter

from reintroduction into service after backwash to breakthrough of

turbidity at the end of the filter run. Some plants have installed

filter-to-waste facilities which allow the discharge of the first

minutes of a filter's operation after backwashing usually into the

backwash reclamation system. In California, the State drinking water

regulations define filter-to-waste as: ` ``Filter-to-waste'' means a

provision in a filtration process to allow the first filtered water,

after backwashing a filter, to be wasted or reclaimed.' (McGuire, 1994)

BILLING CODE 6560-50-P

[[Page 59514]]

[GRAPHIC] [TIFF OMITTED] TP03NO97.048

BILLING CODE 6560-50-C

Figure 7 shows a general schematic of a filter-to-waste operation.

After the backwash process is complete and the filter influent water is

allowed to enter the filter, Valve A is operated so that all of the

filter effluent water is sent to waste. After a specified period of

time or when it is determined that the ripening spike is largely over,

Valve A is operated so that the filtered water becomes part of the

product water of the treatment plant.

BILLING CODE 6560-50-P

[[Page 59515]]

[GRAPHIC] [TIFF OMITTED] TP03NO97.049

BILLING CODE 6560-50-C

2. State Drinking Water Regulations

California has specific regulations that deal with backwash recycle

and filter-to-waste. Treatment of backwash recycle flows is covered in

the design of treatment facilities section. For new construction,

utilities are required to install solids removal treatment for recycled

filter backwash water. Also, treated backwash water must be returned to

the ``headworks'' (i.e., the plant influent) of the treatment plant.

Solids removal treatment unit processes are not specified in the

regulation, but new construction must be approved by the California

Department of Health Services (California Health and Safety Code,

Sections 646658 & 64660).

To minimize the filter ripening spike, the California Department of

Health specifies operational requirements such that filtration rates

are increased gradually when filters are placed back into service

following backwashing or any other interruption in the operation of the

filter. When any individual filter is placed back into service

following backwashing or other interruption event, the filtered water

turbidity from that filter cannot exceed any of the following criteria:

2.0 NTU.

1.0 NTU in at least 90 percent of the interruption events

during any consecutive 12-month period.

0.5 NTU after the filter has been in operation for 4

hours.

For new construction, utilities are required to provide filter-to-

waste or add additional coagulant chemicals to backwash water.

3. Literature Overview of Standard of Practice

a. Treatment Reference Texts. The joint ASCE/AWWA (1990) water

treatment plant design book includes one section on page 182 dealing

with washwater disposal and recovery. The section lists several

possibilities including recycling without treatment, equalization and

treatment, and lagoons to provide for both equalization and

sedimentation. On page 188, the backwash recycle facility at the

Duluth, Minnesota plant is described. Chemical addition, flocculation

and clarification comprise the backwash treatment system.

The fourth edition of Water Quality and Treatment contains one

section on pages 988-989 dealing with filter backwash residuals. The

section notes that recovery of ``dirty'' backwash water is becoming

increasingly common and that the volume of backwash water is typically

one to five percent of total plant production. Flow equalization is

listed as the most common approach to dealing with recycling of

backwash water. The section states that ``For conventional plants,

solid separation before return is not common, and some holding tanks

are mixed to keep solids in suspension.'' Direct filtration plants are

noted for needing solids separation

[[Page 59516]]

treatment of backwash water, because there is no sedimentation facility

in a direct filtration plant. Concerns are expressed in the section

about increasing the concentrations of Giardia cysts in the plant

influent with the recycle of untreated backwash water.

A handbook of practice was published in 1987 dealing with water

treatment plant waste management. Backwash water was described as a

major waste stream on page 5 and flow equalization was listed as an

important requirement. The handbook gives specific examples of the size

of backwash basins needed based on the number of filters backwashed and

the backwash frequency. The example discusses tankage volumes that

would allow a maximum 10 percent recycle rate of the backwash water to

the plant influent. Neither clarification nor polymer addition were

mentioned in this early reference (Cornwell et al., 1987).

b. ICR Treatment Plants. Of the 523 treatment plants subject to the

ICR, 282 use conventional treatment. Of the conventional treatment

plants, 146 (or 52%) practice recycling of their backwash water.

Additionally, 15 direct filtration plants and 3 in-line filter plants

recycle their backwash water. These data show that

This text is long and has been trimmed here. Open the source document for the complete record.

This is a copy of a public record, reproduced as it was published. It is not legal advice, and it may not be the version a court would rely on. Check the official source before you cite it.

A word about cookies

We need a few to keep you signed in and the library working. The rest help us see which pages people use and where they get stuck. They stay off unless you say yes.