Energy Conservation Program for Consumer Products: Final Rule Regarding Energy Conservation Standards for Room Air Conditioners

Federal RegisterSep 24, 1997

Ask Donna

What actually matters in this document.

Text

DEPARTMENT OF ENERGY

Office of Energy Efficiency and Renewable Energy

10 CFR Part 430

[Docket Numbers EE-RM-90-201 and EE-RM-93-801-RAC]

RIN 1904-AA38

Energy Conservation Program for Consumer Products: Final Rule

Regarding Energy Conservation Standards for Room Air Conditioners

AGENCY: Office of Energy Efficiency and Renewable Energy, Department of

Energy (DOE).

ACTION: Final Rule.

-----------------------------------------------------------------------

SUMMARY: The Department of Energy (DOE or Department) has determined

that revised energy conservation standards for room air conditioners

will result in a significant conservation of energy, are

technologically feasible, and are economically justified. On this

basis, the Department is today amending the existing energy

conservation standards for room air conditioners. The Department

projects the standards to save 0.64 quad of energy through 2030, which

is likely to result in a cumulative reduction of emissions of

approximately 95,000 tons of nitrogen dioxide and 54 million tons of

carbon dioxide.

EFFECTIVE DATE: The effective date of the standards is October 1, 2000.

ADDRESSES: A copy of the Technical Support Document (TSD) for this

product may be read at the DOE Freedom of Information Reading Room,

U.S. Department of Energy, Forrestal Building, Room 1E-190, 1000

Independence Avenue, SW., Washington, DC 20585, (202) 586-3142, between

the hours of 9:00 a.m. and 4:00 p.m., Monday through Friday, except

Federal holidays. Copies of the TSD may be obtained from: U.S.

Department of Energy, Office of Energy Efficiency and Renewable Energy,

Forrestal Building, Mail Station EE-43, 1000 Independence Avenue, SW.,

Washington, DC 20585. (202) 586-9127.

FOR FURTHER INFORMATION CONTACT:

Kathi Epping, U.S. Department of Energy, Office of Energy Efficiency

and Renewable Energy, Forrestal Building, Mail Station EE-43, 1000

Independence Avenue, SW., Washington, DC 20585, (202) 586-7425

Eugene Margolis, Esq., U.S. Department of Energy, Office of General

Counsel, Forrestal Building, Mail Station GC-72, 1000 Independence

Avenue, SW., Washington, D.C. 20585, (202) 586-9507.

SUPPLEMENTARY INFORMATION:

I. Introduction

a. Authority

b. Background

II. Summary of Final Rule

III. Discussion of Comments

a. Room Air Conditioner Comments

1. Classes

2. Design Options

3. Engineering Simulation Model

4. Proposed Efficiency Standards

5. Other Comments

6. Other Comments Regarding FR Notice of January 29, 1997

b. General Analytical Comments

IV. Analysis of Room Air Conditioner Standards

a. Efficiency Levels Analyzed

b. Significance of Energy Savings

c. Economic Justification

1. Economic Impact on Manufacturers and Consumers

2. Life-cycle Cost and Net Present Value

3. Energy Savings

4. Lessening of Utility or Performance of Products

5. Impact of Lessening of Competition

6. Need of the Nation to Save Energy

7. Other Factors

d. Payback Period

e. Conclusion

V. Procedural Issues and Regulatory Review

a. Review Under the National Environmental Policy Act

b. Review Under Executive Order 12866, ``Regulatory Planning and

Review''

c. Review Under the Regulatory Flexibility Act

d. Review Under the Paperwork Reduction Act

e. Review Under Executive Order 12988, ``Civil Justice Reform''

f. ``Takings'' Assessment Review

g. Federalism Review

h. Review Under the Unfunded Mandates Reform Act

i. Review Under Small Business Regulatory Enforcement Fairness

Act of 1996

I. Introduction

a. Authority

Part B of Title III of the Energy Policy and Conservation Act, Pub.

L. 94-163, as amended by the National Energy Conservation Policy Act

(NECPA), Pub. L. 95-619, the National Appliance Energy Conservation Act

(NAECA), Pub. L. 100-12, the National Appliance Energy Conservation

Amendments of 1988 (NAECA 1988), Pub. L. 100-357, and the Energy Policy

Act of 1992 (EPAct), Pub. L. 102-486,1 created the Energy

Conservation Program for Consumer Products other than Automobiles. The

consumer products subject to this program are called ``covered

products.'' The covered products specified by statute include room air

conditioners. EPCA, section 322, 42 U.S.C. 6292.

---------------------------------------------------------------------------

\1\ The Energy Policy and Conservation Act, as amended by the

National Energy Conservation Policy Act, the National Appliance

Energy Conservation Act, the National Appliance Energy Conservation

Amendments of 1988, and the Energy Policy Act of 1992, is referred

to in this notice as the ``EPCA.'' Part B of Title III is codified

at 42 U.S.C. 6291 et seq.

---------------------------------------------------------------------------

For room air conditioners, EPCA prescribes an initial Federal

energy conservation standard effective in 1990 and specifies that the

Department shall publish a final rule no later than January 1, 1992, to

determine if the 1990 standards should be amended. A second review must

be completed within five years after publication of this final rule.

EPCA, section 325(c), 42 U.S.C. 6295(c). Any new or amended standard is

required to be designed so as to achieve the maximum improvement in

energy efficiency that is technologically feasible and economically

justified. EPCA, 325(o)(2)(A), 42 U.S.C. 6295(o)(2)(A). The Secretary

may not prescribe any amended standard which increases the maximum

allowable energy use or decreases the minimum required energy

efficiency of a covered product. EPCA, section 325(o)(1), 42 U.S.C.

6295(o)(1).

Section 325(o)(2)(B) provides that DOE, in determining whether a

standard is economically justified, must determine whether the benefits

of the standard exceed its burdens, based, to the greatest extent

practicable, on a weighing of the following seven factors:

(1) The economic impact of the standard on the manufacturers and on

the consumers of the products subject to such standard;

(2) The savings in operating costs throughout the estimated average

life of the covered product in the type (or class) compared to any

increase in the price of, in the initial charges for, or maintenance

expenses of, the covered products which are likely to result from the

imposition of the standard;

(3) The total projected amount of energy savings likely to result

directly from the imposition of the standard;

(4) Any lessening of the utility or the performance of the covered

products likely to result from the imposition of the standard;

(5) The impact of any lessening of competition, as determined in

writing by the Attorney General, that is likely to result from the

imposition of the standard;

(6) The need for national energy conservation; and

(7) Other factors the Secretary considers relevant.

In addition, section 325(o)(2)(B)(iii) establishes a rebuttable

presumption of economic justification in instances where the Secretary

determines that

[[Page 50123]]

``the additional cost to the consumer of purchasing a product complying

with an energy conservation standard level will be less than three

times the value of the energy savings during the first year that the

consumer will receive as a result of the standard, as calculated under

the applicable test procedure.''

b. Background

The purpose of this rulemaking is to review the energy conservation

standards for room air conditioners. In 1990, DOE published an advance

notice of proposed rulemaking with regard to standards for nine covered

products, including room air conditioners. 55 FR 39624 (September 28,

1990) (hereinafter referred to as the September 1990 advance notice).

The September 1990 advance notice presented the product classes that

DOE planned to analyze and provided a detailed discussion of the

analytical methodology and models that the Department expected to use.

On March 4, 1994, DOE published a notice of proposed rulemaking

(NOPR) concerning eight products, including room air conditioners. 59

FR 10464 (March 4, 1994) (hereinafter referred to as the Proposed

Rule). The standards the Department proposed for room air conditioners

are shown in the following table:

Table 1-1.--Proposed Standards Levels for Room Air Conditioners

------------------------------------------------------------------------

Energy efficiency ratio

---------------------------------------

Product class Current standards Standards proposed

(effective January in 1994 Proposed

1, 1990) Rule

------------------------------------------------------------------------

1. Without reverse cycle, with

louvered sides, and less than

6,000 Btu/h.................... 8.0 11.1

2. Without reverse cycle, with

louvered sides, and 6,000 to

7,999 Btu/h.................... 8.5 10.3

3. Without reverse cycle, with

louvered sides, and 8,000 to

13,999 Btu/h................... 9.0 11.0

4. Without reverse cycle, with

louvered sides, and 14,000 to

19,999 Btu/h................... 8.8 11.1

5. Without reverse cycle, with

louvered sides, and 20,000 Btu/

h or more...................... 8.2 9.6

6. Without reverse cycle,

without louvered sides, and

less than 6,000 Btu/h.......... 8.0 10.7

7. Without reverse cycle,

without louvered sides, and

6,000 to 7,999 Btu/h........... 8.5 9.9

8. Without reverse cycle,

without louvered sides, and

8,000 to 13,999 Btu/h.......... 8.5 10.7

9. Without reverse cycle,

without louvered sides, and

14,000 to 19,999 Btu/h......... 8.5 10.8

10. Without reverse cycle,

without louvered sides, and

20,000 Btu/h or more........... 8.2 9.3

11. With reverse cycle and with

louvered sides................. 8.5 10.8

12. With reverse cycle and

without louvered sides......... 8.0 10.4

------------------------------------------------------------------------

DOE received over 8,000 comments during the comment period on the

1994 Proposed Rule and from participants at public hearings held in

Washington, DC on April 5-7 and June 7-8, 1994. Most of the comments

related to other products; twelve of the comments dealt specifically

with room air conditioners.

After reviewing the comments on the proposed standards for room air

conditioners, the Department concluded that a number of significant

issues were raised which required additional analysis. In 1995, the

Department revised the analyses regarding room air conditioners to

account for the comments and data received during the public comment

period. (This revised analysis became the basis for the 1996 Draft

Report.)

A moratorium was placed on publication of proposed or final rules

for appliance efficiency standards as part of the FY 1996

appropriations legislation. Pub. L. 104-134. That moratorium expired on

September 30, 1996.

In 1995 and 1996, the Department conducted a review of its process

for developing appliance energy efficiency standards. This review

resulted in the publication of a final rule, entitled ``Procedures for

Consideration of New or Revised Energy Conservation Standards for

Consumer Products'' (hereinafter referred to as the Process Rule). 61

FR 36973 (July 15, 1996). Although the new procedures in the Process

Rule do not apply to this rulemaking, 61 FR at 36980, DOE has employed

an approach consistent with the new procedures in completing work on

this rule. In keeping with the new process, and based on comments

received in response to the Proposed Rule, DOE distributed for comment

a Draft Report on the Potential Impact of Alternative Energy Efficiency

Levels for Room Air Conditioners (hereinafter referred to as Draft

Report). The Draft Report contained DOE's revised analysis, begun in

1995, examining five alternative efficiency levels. The Draft Report

was distributed to a mailing list that included all of the commenters

on the proposed rule on room air conditioners on May 5, 1996. (EE-RM-

93-801-RAC 2 No. 1 and No. 2.) The letter invited comment on

the Draft Report by no later than July 1, 1996.

---------------------------------------------------------------------------

\2\ EE-RM-90-201 refers to the docket for the September 1990

advance notice and the 1994 Proposed Rule. Docket No. EE-RM-93-801-

RAC contains the 1996 Draft Report, comments to the 1996 Draft

Report, comments to the 1997 reopening notice, and the supplemental

analysis.

---------------------------------------------------------------------------

Between the beginning of June and the end of November 1996, DOE

received six comments on the Draft Report and related issues. DOE

officials also held meetings on September 26 with representatives of

the Association of Home Appliance Manufacturers (AHAM) and interested

manufacturers and on September 27 with the American Council For an

Energy Efficient Economy (ACEEE), the Alliance to Save Energy, the

Natural Resources Defense Council (NRDC), and State energy officials

from California, Florida, and Oregon. (EE-RM-93-801-RAC No. 11 and No.

12.)

On the basis of these comments, DOE prepared a TSD which comprises

the Draft Report and a supplemental analysis conducted on a candidate

standard level not included in the Draft Report. The supplemental

analysis focused on a set of efficiency levels for the same 9 classes

analyzed in the proposed rule. (EE-RM-93-801-RAC No. 13.)

In a Federal Register (FR) Notice dated January 29, 1997, the

Department reopened the comment period for room air conditioners for 15

days. This notice announced the availability of the supplemental

analysis and gave indication of the standard levels the Department was

inclined to promulgate in the final rule. The Department received 4

comments in response to this notice.

II. Summary of Final Rule

The standards set forth in today's rule are projected to save

approximately 0.64 quad of energy through 2030. Although

[[Page 50124]]

the standards in the Proposed Rule were projected to save 2.2 quads,

DOE has concluded, based on public comment and further analysis, that

the proposed standards are not economically justified. The standard

levels set forth in today's rule are significantly less costly than

those standards in the proposed rule. The following table presents the

standards established in today's rule:

------------------------------------------------------------------------

Energy efficiency ratio, effective as

of

Product class ---------------------------------------

January 1, 1990 October 1, 2000

------------------------------------------------------------------------

1. Without reverse cycle, with

louvered sides, and less than

6,000 Btu/h.................... 8.0 9.7

2. Without reverse cycle, with

louvered sides, and 6,000 to

7,999 Btu/h.................... 8.5 9.7

3. Without reverse cycle, with

louvered sides, and 8,000 to

13,999 Btu/h................... 9.0 9.8

4. Without reverse cycle, with

louvered sides, and 14,000 to

19,999 Btu/h................... 8.8 9.7

5. Without reverse cycle, with

louvered sides, and 20,000 Btu/

h or more...................... 8.2 8.5

6. Without reverse cycle,

without louvered sides, and

less than 6,000 Btu/h.......... 8.0 9.0

7. Without reverse cycle,

without louvered sides, and

6,000 to 7,999 Btu/h........... 8.5 9.0

8. Without reverse cycle,

without louvered sides, and

8,000 to 13,999 Btu/h.......... 8.5 8.5

9. Without reverse cycle,

without louvered sides, and

14,000 to 19,999 Btu/h......... 8.5 8.5

10. Without reverse cycle,

without louvered sides, and

20,000 Btu/h or more........... 8.2 8.5

11. With reverse cycle, with

louvered sides, and less than

20,000 Btu/h................... 8.5 9.0

12. With reverse cycle, without

louvered sides, and less than

14,000 Btu/h................... 8.0 8.5

13. With reverse cycle, with

louvered sides, and 20,000 Btu/

h or more...................... 8.5 8.5

14. With reverse cycle, without

louvered sides, and 14,000 Btu/

h or more...................... 8.0 8.0

15. Casement-Only............... ( \1\ ) 8.7

16. Casement-Slider............. ( \1\ ) 9.5

------------------------------------------------------------------------

\1\ Casement-only and casement-slider room air conditioners are not

separate product classes under standards effective January 1, 1990.

These units are subject to the applicable standards in classes 1

through 14 based on unit capacity and the presence or absence of

louvered sides and a reverse cycle.

III. Discussion of Comments

a. Room Air Conditioner Comments.

This section addresses comments to the 1994 Proposed Rule, the 1996

Draft Report, and the 1997 reopening notice. The ``RAC'' notation

signifies that the following comment is from Docket No. EE-RM-93-801-

RAC which contains comments to the 1996 Draft Report and the 1997

reopening notice. All other comments are from Docket No. EE-RM-90-201

which contains comments from the 1994 Proposed Rule. Note that the

Draft Report addressed many of the comments to the 1994 Proposed Rule.

1. Classes

In the 1994 Proposed Rule, the Department proposed fourteen classes

of room air conditioners. These product classes consisted of five

categories; units with side louvers, units without side louvers, units

with reversing valve and with side louvers, units with reversing valve

and without side louvers, and casement-type units. There were five

class divisions by capacity within each of the two categories without

reversing valves. Casement-type units were divided into the following

two classes: casement only units and casement-slider units.

Units with louvered sides and without reversing valves. The

California Energy Commission (CEC) proposed a reduction in product

classes from twelve to four, eliminating the class divisions based on

capacity. They stated that the profusion of classes makes comparison of

models difficult since the label-reading consumer does not compare all

the models available. In addition, disincentives could be created that

discourage manufacturers from making efficiency improvements to models

near capacity breakpoints because design changes can push the capacity

into the next category which has a higher or lower standard level.

(CEC, No. 539 at 2-3.) Fedders Corporation (Fedders) proposed that the

three smallest capacity classes for units with side louvers and without

reversing valve be consolidated into a single class. It called for this

consolidation due to the disparity in cost and dehumidifying capability

that would arise from having significantly different efficiency

standards promulgated for these three classes. (Fedders, April 7, 1994,

Transcript at 120-122.) AHAM proposed that the Department retain the

current five capacity class divisions for units with side louvers and

without reversing valves. (AHAM, No. 1 at 2.)

In the 1994 Proposed Rule, DOE explained that performance and

installation constraints necessitate class divisions by capacity.

Manufacturers limit their production of cabinets to three or four

sizes. Units of similar capacity tend to be designed for the same

cabinet size. The space and configuration limitations imposed by the

cabinet tend to produce units with similar efficiencies. Because

efficiency is essentially a function of cabinet size, and thus

capacity, class divisions by capacity are warranted. In the Final Rule,

the minimum efficiency standards for each of the four classes with

louvered sides and capacities less than 20,000 Btu/h all have nearly

the same efficiency value (efficiencies range from 9.7 to 9.8 EER),

reducing the concern about inappropriate incentives to change product

capacity to take advantage of capacity based standards. The Department

agrees with AHAM that the current 5 capacity-based classes should be

retained.

Units without louvered sides and without reversing valves. AHAM,

Frigidaire Company (Frigidaire), and Sanyo Electric Company (Sanyo)

proposed that classes without louvered sides and without reversing

valve be consolidated into two classes: units with capacities of less

than 8,000 Btu/h and units with capacities greater than or equal to

8000 Btu/h. (AHAM, No. 1 at 2; Frigidaire, No. 544 at 5; Sanyo, No. 771

at 3.) AHAM states that the capacity classes established for units with

side louvers and without reverse cycle are not particularly applicable

to the other types of classes. (AHAM, RAC No. 4 at 1.) In support of

making this recommendation, AHAM stated that since the 1990 minimum

efficiency standards became effective, models without louvered sides

have been produced only in the 6,000 to 7,999 Btu/h capacity class or

the 8,000 to 13,999 Btu/h class. The sizes of existing sleeves and the

efficiency standards have constrained capacities to these two classes.

(AHAM, No. 1 at 20.) In its comments to the 1996 Draft report, AHAM

again urged the Department to reduce the number of classes from five

[[Page 50125]]

to two for these units. (AHAM, RAC No. 4 at Attachment 1 pg. 1.)

As discussed with respect to classes with louvered sides and

without reversing valves, class divisions by capacity are warranted for

units without louvered sides because of the effect that economic and

installation constraints have on capacity and efficiency. Although

manufacturers currently do not produce units in two of the existing

five capacity classes, the Department has decided not to consolidate

these classes into those units with capacities less than and greater

than 8,000 Btu/h. However, the new standards for the two classes of

units less than 8,000 Btu/h are the same (9.0 EER) and the new

standards for the three classes of units with capacities of 8,000 Btu/h

or more are the same (8.5 EER.) In the future, manufacturers might

produce units in classes where none are currently being produced. For

example, models are now being produced in the less than 6000 Btu/h

class where models were not being manufactured previously. Therefore,

the Department will retain all five of the existing classes for units

without louvers and without reverse cycle.

Units with reversing valves. AHAM and Sanyo proposed that units

with reversing valves be consolidated into a single class if the

efficiency standard specified for them is a single fixed EER difference

below all other cooling-only classes (i.e., classes without reversing

valve.) A fixed EER difference of 0.5 EER was proposed. (AHAM, No. 1 at

2; Sanyo, No. 771 at 3.) This recommendation essentially creates as

many classes for units with reversing valves as there are for units

without reversing valves. Both Whirlpool Corporation (Whirlpool) and

Fedders agreed with this recommendation. (Whirlpool, April 7, 1994,

Transcript at 106; Fedders, April 7, 1994, Transcript at 136.) In a

April 23, 1996 joint letter to AHAM, ACEEE and NRDC agreed with the

fixed 0.5 EER difference between reverse-cycle classes and their

corresponding ``cool-only'' classes. (ACEEE/NRDC, RAC No. 3 at 4.) In

addition, during a meeting with ACEEE, Alliance to Save Energy,

California Energy Commission, Florida Energy Office, Oregon Department

of Energy, and NRDC, a recommendation was made to refer to reverse

cycle products as ``heat pump air conditioners'' in the future. (RAC

No. 10 at 2.) AHAM responded that these systems are not designed to be

sophisticated heat pumps but rather to modify a room air conditioner by

adding a reverse cycle to ``make it function as a heat pump within the

confines of a relatively small enclosure.'' (AHAM, RAC No. 6 at 3.)

The Department has determined its current class structure for units

without reversing valves (two product classes: one for units with

louvered sides and another for units without louvered sides) is not

adequate. Therefore, the Department is adding two classes for units

with reverse cycle to accommodate the concerns expressed in public

comments. The two additional classes are class 13--units with reverse

cycle, with louvers, and with a capacity of 20,000 Btu/h or more--and

class 14--units with reverse cycle, without louvers, and capacity of

14,000 Btu/h or more.

Casement-Type Units. In the 1994 Proposed Rule, the Department

proposed additional classes for casement-slider and casement-only room

air conditioners because of the unique utility they offer to the

consumer. Casement-type units offer a performance-related feature

(fitting into casement windows) which other room air conditioners

cannot provide. AHAM and Frigidaire supported the Department's proposal

to establish separate classes for casement only and casement/slider

units. In addition, AHAM stated that because of the limited number of

models available and the narrow range of capacities, class divisions by

capacity are not necessary for these unit types. (AHAM, No. 1 at 21-22;

Frigidaire, No. 544 at 6.) In their comments to the Draft Report, ACEEE

and NRDC recommended that casement-only units be combined in the same

category as casement-slider units due to the fact that there is only

one casement-only unit on the market. ACEEE and NRDC are also concerned

that a loophole may be created because lower-priced casement units may

be used in applications that do not require the special dimensions

required by casement-only units. They commented that adjustable side

panels can be used to enclose the space created when a window is wider

than the air conditioner. (ACEEE/NRDC, RAC No. 5 at 4.)

The Department believes that the size limitations imposed on

casement-type units are more significant than those faced by typical

units which are designed for double-hung windows. Since this

performance-related feature justifies a lower efficiency standard,

separate classes will be established for casement-slider and casement-

only units. The Department agrees with AHAM that class divisions by

capacity are not necessary because of the narrow range of capacities in

which models are currently available. According to AHAM's Directory of

Certified Room Air Conditioners, casement-slider units range in

capacity from 5,000 to 11,000 Btu/h, while there is currently only one

casement-only unit, which has a capacity of 6,200 Btu/h. The Department

believes that there is utility added by having a casement-only as well

as a casement-slider class. In addition, the Department believes that

the dimensions of casement units are restrictive enough to prevent a

loophole.

Ductless Split Systems. Fedders proposed that ductless split system

air conditioners be regulated under room air conditioner efficiency

standards as it believes that they are directly competing against room

air conditioners for market share. (Fedders, April 7, 1994, Transcript

at 123.) The NRDC agreed with the Fedders recommendation. (NRDC, No. 55

at 28)

The Department's efficiency standards for split system-type central

air conditioners also apply to ductless split systems. The Department

makes no distinction between split systems which deliver conditioned

air with or without ducts. Thus, because split systems are covered

under standards for central air conditioners, ductless split system air

conditioners will not be established as an additional class for room

air conditioners.

2. Design Options

Commenters provided detailed comments on several of the design

options that were analyzed by the Department for the proposed

rulemaking.

Rotary compressors. Compressor efficiency was the design option

that drew the greatest amount of comment. AHAM, Amana Refrigeration,

Inc. (Amana), Frigidaire, Fedders, Sanyo, Matsushita Electric

Corporation (Matsushita), Whirlpool, and Tecumseh Corporation

(Tecumseh) all provided comments stating that rotary compressors cannot

attain the 11.5 to 12.0 EER efficiency levels assumed in the

Department's analysis. They stated that the maximum efficiency of

currently available rotary compressors falls in the 10.7 to 10.9 EER

range. Compressor manufacturers stated that only minor efficiency

improvements are expected within the next three to five years. The

combined effect of these efficiency improvements would yield only a

11.1 to 11.3 EER rotary compressor. And although efficiency increases

of this magnitude may be theoretically achievable, they would require

the development of high-efficiency motors which are currently not

available, use of higher-grade materials in the rotary compressor

[[Page 50126]]

mechanism, and new compressor production methods and equipment. Both

AHAM and Amana additionally commented that physical samples of new

compressors need to be available to room air conditioner manufacturers

at least 36 months prior to the effective date of the standards to

provide adequate time for development, reliability and field testing.

(AHAM, No. 1 at 7; Amana, Inc., No. 347 at 1; Frigidaire, No. 544 at 2;

Fedders, April 7, 1994, Transcript at 121-122; Sanyo, No. 771 at 7-9;

Matsushita, April 7, 1994, Transcript at 88-90; Tecumseh, April 7,1994,

Transcript at 97-99; Whirlpool, April 7, 1994, Transcript at 102-103.)

ACEEE commented that compressor efficiencies have been improving in

recent years and are still below the theoretical limit. It stated that

according to trade press articles, rotary and reciprocating compressors

with efficiencies exceeding 11.0 EER are already available and further

increases in efficiency are being developed. It argues that if 11.5 to

12.0 EER compressors are not realized, other technologies could be used

to attain the Department's proposed efficiency levels. (ACEEE, No. 557

at 21.) ACEEE and NRDC commented that slightly more efficient

compressors which are likely to become available soon should be used in

the analyses in future rulemakings. (ACEEE/NRDC, RAC No. 5 at 1.)

The Department rejects AHAM's suggestion that design options must

be available 36 months prior to the effective date of the standards.

However, the prediction in the 1994 Proposed Rule that 11.5 to 12.0 EER

compressors would be available by the year new efficiency standards

would become effective was based on development plans of a compressor

manufacturer to produce 11.6 to 12.0 EER compressors. Subsequently,

those development plans were canceled. Because rotary compressor

manufacturers state that they cannot produce compressors with

efficiency levels approaching the 11.5 to 12.0 EER range, the

Department, in the Draft Report, analyzed only rotary compressors which

are currently on the market. Depending on their capacity, the most

efficient rotary compressors range in efficiency from 10.7 to 11.1 EER.

In its comments to the 1996 Draft Report, AHAM stated that the revised

report addressed its concerns. (AHAM, RAC No. 4 at Attachment 1, pg 2.)

Scroll compressors. Only AHAM provided comments regarding scroll

compressors. It stated that scroll compressors are currently not

available in capacities less than 18,000 Btu/h and that efficiencies

are either no more or slightly more efficient than rotary compressors.

In addition, scroll compressor application heights are typically three

to five inches greater than comparable rotary compressors, therefore

requiring a larger chassis. Copeland Corporation (Copeland), a scroll

compressor manufacturer, was cited by AHAM as having announced plans to

develop a new, smaller scroll design optimized in the 14,000 to 24,000

Btu/h capacity range. AHAM stated this design could be expanded

effectively into room air conditioner applications with more reasonable

cost premiums and with efficiencies possibly in the 11.5 to 12.0 EER

range, but because it is not possible to make these compressors

available to manufacturers 36 months prior to the effective date of new

standards, they should not be considered by the Department for this

rulemaking. (AHAM, No. 1 at 8.) Again, ACEEE and NRDC in their joint

comments to the Draft Report stated that slightly more efficient

compressors which are likely to become available soon should be used in

the analyses in future rulemakings. (ACEEE/NRDC, RAC No. 5 at 1.)

Again, the Department rejects AHAM's suggestion that design options

must be available 36 months prior to the effective date of the

standards. Although Copeland Corporation is currently investigating

this more efficient compressor technology in the 14,000 to 24,000 Btu/h

capacity range, they could not commit to produce it. Because there was

not sufficient evidence this technology would be available by the

effective date of the standards, only Scroll compressors which are

currently on the market were considered for the Department's Final Rule

analysis. For compressors which would be suitable for room air

conditioner applications, Copeland's scroll compressors currently range

in efficiency from 10.8 to 11.1 EER. The lowest capacity scroll

compressor offered by Copeland is 16,500 Btu/h. Thus, scroll

compressors were only considered for room air conditioners with

capacities of at least 16,000 Btu/h. The information DOE received from

compressor manufacturers showed that scroll compressor heights are only

1-2 inches greater than comparable rotary compressors. Moreover,

because this design option was not contained in any of the standard

levels the Department found to be economically justified, the

Department does not consider this height differential to be an issue.

AHAM commented that it was satisfied with the treatment of this issue

in the Draft Report. (AHAM, RAC No. 4 at Attachment 1 pg. 2.)

Reciprocating compressors. The Department's analysis of an advanced

reciprocating compressor design called the inertia compressor received

comments by AHAM, Frigidaire, and Bristol Compressors (Bristol.) All

three commented that inertia compressors with efficiencies in the range

of 11.5 to 12.0 EER are expected to be available within the next couple

of years but only in capacities exceeding 18,000 Btu/h. Inertia

compressors are significantly heavier, larger, and noisier than the

rotary compressors that are currently used in room air conditioner

applications. Larger chassis sizes would be required to accommodate the

increased weight and size of the inertia compressor. In addition, sound

blankets would be necessary to muffle the increased noise levels. Thus,

cost premiums and the accompanying application costs make inertia

compressors difficult to cost justify for room air conditioners. (AHAM,

No. 1 at 8-9; Frigidaire, No. 544 at 2; Bristol, June 7, 1994,

Transcript at 355-362.)

Although the Department recognizes that advanced reciprocating

compressors are heavier and larger than existing rotary compressors, no

information was provided as to how great the application costs for

enlarging and bracing the chassis would be for incorporating them into

room air conditioner units. Thus, only the cost of the compressor

itself, with its accompanying sound blanket, was explicitly included in

the Department's Final Rule analysis. For those instances where the

advanced reciprocating compressor exceeded the weight of the rotary

compressor by a significant amount (over 30 percent), an increase in

chassis size was assumed to be necessary for incorporating the larger

and heavier compressor. Therefore, a design option which resulted in a

chassis size increase (i.e., increased evaporator and condenser face

areas) always preceded the incorporation of an advanced reciprocating

compressor. The added costs for increasing the chassis were assumed to

cover the expense of incorporating the reciprocating compressor. For

compressors which would be suitable for room air conditioner

applications, Bristol's inertia compressors currently range in

efficiency from 11.2 to 11.8 EER. The lowest capacity inertia

compressor offered by Bristol is 18,000 Btu/h. Thus, inertia

compressors were considered only for room air conditioners with

capacities of at least 18,000 Btu/h. In its comments to the 1996 Draft

Report, AHAM indicated that this approach

[[Page 50127]]

addressed its concerns. (AHAM, RAC No. 4 at Attachment 1 pg 2.)

Fan motor efficiency. Only AHAM provided comments with regard to

improvements in fan motor efficiency. It stated that permanent split

capacitor (PSC) fan motors are already used in 98 percent of room air

conditioners. The efficiency of PSC fan motors fall in the range of 50

percent to 70 percent with larger motors being more efficient. AHAM

admitted that some modest gains may be achieved with PSC fan motors in

specific applications. With regard to electronically commutated motors

(ECM), otherwise known as brushless permanent magnet motors (BPM), AHAM

stated that they cost 2.5 to 3 times more than standard PSC motors. In

addition, they weigh approximately twice that of a standard PSC motor.

ECM efficiencies range from 68 percent to 78 percent. ECMs are

currently not available with the double ended shaft required for room

air conditioner applications because controls block one end of the

motor. AHAM believes that ECMs with double ended shafts are not likely

to be made available in the foreseeable future. Even if ECMs were

manufactured with double ended shafts, AHAM claimed that manufacturers

would need physical samples 24 months before the effective date of

standards. (AHAM, No. 1 at 10 and RAC No. 4 at 5.)

The Department recognizes that most room air conditioner designs

already incorporate permanent split capacitor fan motors. But for two

of the product classes analyzed, the representative baseline units used

inefficient shaded pole motors. Thus, for these two classes,

significant efficiency gains were achieved by replacing the shaded pole

motors with more efficient permanent split capacitor motors. For all

other classes, the representative baseline units already incorporate

permanent split capacitor motors. Further fan motor efficiency

increases were assumed to be achieved only through the use of ECMs.

Although current ECM controls are situated at one end of the motor, the

Department believes that there is no reason why they cannot be moved to

another location on the motor. Thus, it is assumed that ECMs can be

manufactured with double ended shafts. Although the Department

recognizes that ECMs weigh approximately twice as much as standard

permanent split capacitor motors, no information was provided about the

application costs for bracing the chassis to incorporate them into room

air conditioner units. Thus, only the cost of the ECM itself was

explicitly taken into account in the Department's Final Rule analysis.

However, because the analysis showed that ECMs were not an advantageous

design option, any cost increases due to increased ECM weight need not

be considered further. In its comments to the 1996 Draft Report, AHAM

indicated that the analysis, which assumes a fan motor efficiency of 30

percent for shaded pole and 50 percent for permanent split capacitor

(PSC) when changing from a shaded pole to a PSC, addresses its concern.

(AHAM, RAC No. 4 at Attachment 1, pg. 2.)

Variable speed compressors. AHAM stated that variable speed

compressors are not currently used in room air conditioner applications

and should not be considered a technically viable design option. AHAM

commented that the cost premium is 30 percent to 50 percent above

comparable single-speed compressors. Although variable speed

compressors are available off-shore in capacities and sizes suitable

for use in room air conditioners, improvements in efficiency cannot be

measured with the Department's current test procedure. AHAM commented

that the Department's current single condition test procedure

adequately matches consumer usage patterns for room air conditioners.

(AHAM, No. 1 at 12.) AHAM does not believe variable speed compressors

are ``capable of being assembled into room air conditioners by the

effective date'' and should not be considered a viable design option.

(AHAM, RAC No. 4 at 5.)

Although the Department recognizes that the current test procedure

is not adequate for determining the benefits due to variable speed

compressors, they are still analyzed as a design option for room air

conditioners. As done for the Proposed Rule's analysis, efficiency

gains are established based on estimates from central air conditioning

applications. The efficiency improvement, because it is primarily a

result of reduced cycling (i.e., reduced on and off operation), is

reported in terms of the seasonal energy efficiency ratio (SEER). A

minimum efficiency standard cannot be based on its inclusion because

the current test procedure does not recognize a SEER rating as an

appropriate measure of efficiency. In addition, variable speed

compressors were not included in any of the efficiency levels DOE

determined to be economically justified.

Heat exchanger design options. A number of comments were received

regarding design changes to improve heat exchanger (evaporator and

condenser) performance. These improvements can be put into two

categories: designs for increasing the heat exchanger surface area and

designs for increasing the heat transfer coefficients. The heat

transfer surface area can be increased by any of the following methods:

increasing the frontal area of the coil by increasing the height or

width; adding a subcooler to the condenser coil; increasing the depth

of the coil by adding vertical tube rows; or increasing the fin

density. The heat transfer coefficients can be increased by using an

enhanced fin design or grooved (rifled) refrigerant tubing.

With regard to heat exchanger improvements, manufacturers expressed

great concern over design options that would require an increase in

chassis size, namely, increases in heat exchanger size. AHAM claimed

that tooling for a new chassis size can range in cost from $1.5 to $5.0

million per manufacturer. In addition, it stated that there are limits

to the efficiency that can be achieved through increases in coil size

without causing problems with latent cooling capacity (i.e.,

dehumidification.) It also stated that if standards require larger

chassis sizes, there will be loss of utility in terms of portability

and availability of larger capacities that can fit into smaller

windows. In addition, availability of very large capacities would be

reduced. (AHAM, No. 1 at 11-12.) AHAM also stated that an increase in

coil size could affect compressor reliability. It stated that if room

air conditioner efficiency is increased by enlarging the coil, the

compressor capacity must be reduced to maintain the capacity of the

system. But because the unit now has more refrigerant as a result of

enlarging the coil, it is more likely that the smaller compressor's

maximum charge limitation would be reached. The closer the refrigerant

charge comes to the compressor's charge limit, the more likely that

compressor failure would occur. (AHAM, Transcript, April 7, 1994, at

66.) Amana stated that its current coil designs are already optimized.

(Amana, Inc., No. 347 at 1.) Sanyo stated that increasing the condenser

surface area is not feasible as the chassis enclosure is already too

crowded. (Sanyo, No. 771 at 9.)

AHAM and several manufacturers commented that the Department's

proposed efficiency standards would require increases in chassis size

for all room air conditioner product classes because some design

options that the Department assumed would be available, primarily 11.5

to 12.0 EER compressors, would not exist by the time the proposed

standards became effective. AHAM stated that even a small increase in

the efficiency standard will cause some models to move to a larger

chassis size. According to AHAM,

[[Page 50128]]

92 percent of total production would need to move to a larger chassis

size to meet the standards proposed in the 1994 Proposed Rule. AHAM

further commented that because chassis sizes vary widely among

manufacturers, new standards will have significant competitive effects.

(AHAM, No. 1 at 1, 14-18.) Amana, Whirlpool and Frigidaire all provided

comments reinforcing AHAM's comments. Amana stated that to meet the

Department's proposed standards it would need to redesign nine of

thirteen basic models into a larger chassis. These manufacturers

further commented that the higher prices resulting from chassis size

increases place an unfair burden on low income consumers. (Amana, No.

347 at 1; Whirlpool, No. 391A. at 1; Frigidaire, No. 544. at 3.)

AHAM provided the Department with a graph which shows the

percentage of production which would be required to change chassis size

at each EER. (AHAM No. 1 at 14.) In its comments to the Draft Report,

AHAM states that ``more stringent standards [than the standards

proposed by AHAM] will cause a significant number of chassis size

changes with step function-like cost implications to manufacturers and

raise utility, marketing and competitive issues.'' (AHAM, RAC No. 6 at

1.) AHAM stated the baseline model method of analysis does not

realistically represent the impact on cost of increasing the chassis

size. AHAM believes the Department should weight the cost of a larger

chassis by the proportion of models needing a larger chassis to achieve

specific efficiency levels. (AHAM, RAC No. 4 at 3.) In their most

recent comments, ACEEE and NRDC state this approach is reasonable, but

they believe the life cycle cost minimums, resulting when costs of

chassis size increases are prorated, should be used to select

standards. Referring to the graph provided by AHAM, ACEEE and NRDC

state that the proportion of models requiring a larger chassis size at

9.8 EER is ``scarcely different'' than the proportion required by 9.5

EER and that only at EER levels above 9.8 EER do a significant

proportion of models need a larger chassis. Furthermore, they state

``to consider chassis size as an independent decision-making factor

would overemphasize chassis size in making a final decision.'' (ACEEE/

NRDC, RAC No. 5 at 2.)

The impact of increased heat exchanger size on dehumidification was

assessed with the engineering computer simulation model. The simulation

model not only estimates the efficiency increase that results from

adding more coil area but also its effect on latent heat removal. For

all the room air conditioners which were modeled, the heat exchanger

increases which were analyzed resulted in latent heat ratios of at

least 25 percent. The latent heat ratio is the latent heat rate removal

of the air conditioner divided by its total cooling capacity. AHAM

considers 25 percent to be the minimum acceptable latent heat ratio.

With regard to the issue of compressor reliability, although the

Department recognizes that an increase in coil size coupled with a

decrease in compressor capacity could affect the reliability of the

compressor, manufacturer data were not provided as to the maximum

charge limit of room air conditioner compressors. The Department's

analysis of larger coil sizes assumed that the compressor capacity

would not have to be reduced when analyzing larger coil sizes. Thus,

with regard to how the Department conducted its analysis, it is

unlikely that compressor reliability would be negatively impacted.

Moreover, increasing evaporator/condenser coil area was not contained

in any of the standard levels DOE found to be economically justified.

With regard to the issue that some manufacturers may be

competitively disadvantaged by being required to increase chassis size,

the Department carefully considered the information provided by AHAM

which indicates that the proposed standards in the 1994 Proposed Rule

would require 92 percent of manufacturers to increase chassis size.

Both the Department and AHAM recognize that any change in efficiency

standard will require some manufacturers to increase chassis size. The

Department has attempted to reduce the number of chassis size changes

as much as possible while still achieving the goal of promulgating

standards which maximize energy efficiency consistent with economic

justification. The standards set forth would require an increased

chassis size for a substantially smaller subset--approximately 25

percent--of products.

The Department considered AHAM's recalculations of life-cycle cost

minimums which prorated the cost of chassis size increases. (AHAM, RAC

No. 9 at Attachment 3A.) DOE has selected standard levels corresponding

to the minimum life cycle costs when chassis size cost is prorated for

the classes for which AHAM provided this information (i.e., classes 1

through 5).

AHAM commented that manufacturers will make adjustments to the

number of tube rows and the density of fins in order to optimize heat

exchanger performance. Because heat exchangers are, in general, already

optimized, however, adjusting either the tube rows or the fin density

is not a significant factor in increasing system efficiency. (AHAM, No.

1 at 9.) Sanyo stated that adding tube rows or fin material causes

increased air flow restrictions and requires design changes to fan and

fan motors. If motor speeds are increased to obtain high airflow,

unacceptable noise levels result. (Sanyo, No. 771 at 9.)

The Department agrees with AHAM and Sanyo that the number of tube

rows and the fin density are already optimized to yield the greatest

heat exchanger performance. In using the engineering computer

simulation model, increases in either tube row density or fin density

provided negligible increases in system performance. In its comments to

the 1996 Draft Report, AHAM indicated that because the simulation model

shows negligible increases in system performance by increasing the fin

density and number of tube rows, AHAM is no longer concerned about this

matter. (AHAM, RAC No. 4 at Attachment 1 pg. 2.)

AHAM stated that enhanced fins are already used in 64 percent of

the evaporators produced by manufacturers and 99 percent of the

condensers. AHAM also commented that good projections for the

efficiency improvement due to enhanced fins are not available. AHAM

further commented that the increased use of enhanced fins in

evaporators is likely to be limited because in some cases condensate

drainage is a limiting factor. AHAM believes that additional

significant improvements in fin design are not expected in the

foreseeable future. (AHAM, No. 1 at 10.) Sanyo stated that many models

already employ enhanced fins. (Sanyo, No. 771 at 9.)

The Department recognizes that most room air conditioner designs

incorporate enhanced fins. Consequently, most of the representative

baseline units for the product classes analyzed by the Department

already include enhanced (i.e., slit-type) fins. For those baseline

units where enhanced fins could be added, efficiency improvements were

based on information provided by room air conditioner and heat

exchanger manufacturers. Publicly available research information was

used to check the reasonableness of the data supplied by manufacturers.

The manufacturer information also included data on how densely enhanced

fins could be packed until condensate drainage became a problem. In

accordance with this manufacturer data, the Department's

[[Page 50129]]

analysis limited enhanced fin densities before condensate drainage

became a problem. In its comments to the 1996 Draft Report, AHAM

indicated that this approach addressed its concerns. (AHAM, RAC No. 4

at Attachment 1 pg. 2.)

AHAM stated that grooved refrigerant tubes are already used in 97

percent of the evaporators produced by manufacturers and 86 percent of

the condensers. AHAM also commented that good projections for the

efficiency improvement due to grooved tubes are not available. AHAM

does not expect additional significant improvements in tube design in

the foreseeable future. (AHAM, No. 1 at 10.) Sanyo stated that many

models already employ grooved tubes. (Sanyo, No. 771 at 9.)

As with enhanced fins, the Department recognizes that most room air

conditioner designs already incorporate grooved refrigerant tubing.

However, for many of the representative baseline units that were

selected (with consultation from AHAM) for the Proposed Rule's

analysis, grooved tubing was not incorporated into the design. For the

Department's Proposed Rule analysis, manufacturer test data was used to

determine the efficiency improvements due to grooved tubing. However,

publicly available research data indicated the manufacturer test data

overstated the possible improvement. In addition, the analysis

conducted for the Proposed Rule did not account for the increase in

refrigerant-side pressure drop due to the grooved tubing. Thus, for the

Department's analysis for the Final Rule, efficiency and pressure drop

estimates were based on research data published by the American Society

of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE.) In

its comments to the 1996 Draft Report, AHAM commented that this

approach addressed its concern. (AHAM, RAC No. 4 at Attachment 1 pg.

2.)

In their comments to the Draft Report, ACEEE and NRDC state that

the report seems to ignore a new heat exchanger technology by Modine

Technology that can achieve ``at least a 0.75 increase in EER'' without

changing chassis size. (ACEEE/NRDC, RAC No. 5 at 1.) The advocates

recommend that new technologies such as this one be considered in

future rulemakings. The Oregon Department of Energy also stated its

belief that most manufacturers were in contact with Modine Technology.

(RAC No. 10 at 2.)

The efficiency improvement made possible by the new heat exchanger

technology to which the energy efficiency advocates referred is based

on theoretical calculations. Modine Technology's new heat exchanger has

shown improvements in central air conditioners; however, it has not

been tested in room air conditioners. The Department does intend to

analyze this technology in future rulemakings.

AHAM, Amana, Frigidaire, Fedders, and Sanyo all provided comments

with regard to subcoolers. Test data was provided indicating that the

efficiency improvement due to subcoolers is significantly lower than

that estimated by the Department in the 1994 Proposed Rule. AHAM

presented data indicating that, on average, the actual efficiency and

capacity improvements are 44 percent and 67 percent, respectively, of

that projected by the Department's simulation model. Also, according to

the AHAM, four out of seven room air conditioner manufacturers do not

currently use subcoolers and five of the seven manufacturers would need

to make major tooling changes on all or some of their chassis. (AHAM,

No. 1 at 6-7; Amana, No. 347 at 2; Frigidaire, No. 544 at 2-3; Fedders,

No. 693 at 2-6; Sanyo, No. 771 at 9.)

Based on comments, the Department used manufacturer test data to

calibrate the subcooler efficiency increases that were estimated by the

simulation model. For each room air conditioner model simulated, the

temperature of the condensate into which the subcooler is immersed was

adjusted until the simulated efficiency increase matched that indicated

by the manufacturer test data. Depending on the capacity of the unit,

the manufacturer test data demonstrates unit efficiency increases of

between 1.4 percent to 3.0 percent, as compared to approximately 6

percent increases found in the analysis for the Proposed Rule. The

simulation model was adjusted based on this test data. AHAM indicated

that this approach addressed its earlier concern. (AHAM, RAC No. 4 at

Attachment 1 pg. 2.) In addition, DOE used manufacturer cost

information provided by AHAM to calculate the economic impact of

incorporating a subcooler as one of the room air conditioner design

options.

Design options already in use. Many manufacturers claimed that they

already use many of the design options that are being considered by the

Department for increasing energy efficiency. (AHAM, April 7, 1994,

Transcript at 51-52; Amana, No. 347 at 1; Frigidaire, No. 544 at 4;

Fedders, No. 693 at 1; Sanyo, No. 771 at 8.) Both Amana and Frigidaire

stated that they already use high efficiency rotary compressors,

grooved tubes, enhanced fins and permanent capacitor fan motors. Amana

stated that the only design options available for increasing efficiency

are more efficient compressors, larger coil sizes, larger chassis

sizes, and the addition of a liquid line subcooler. (Amana, No. 347 at

1; Frigidaire, No. 544 at 4.)

The design options which are considered in the analysis are based

on the characteristics of the representative baseline units. The

baseline models used in this analysis were selected through

consultation with AHAM. If a baseline unit does not include particular

design options, then those options are analyzed as measures to improve

the efficiency of the unit. Although some of these design options are

already commonly used, they may not all be used simultaneously. For

example, some of the baseline units used more efficient compressors to

achieve a certain efficiency rating, while many of the units on the

market used less efficient compressors but improved heat exchanger

design options to achieve the same level of efficiency.

3. Engineering Simulation Model

The Department received several comments regarding the engineering

computer simulation model that it used in its analysis of efficiency

improvements for room air conditioners. Comments were provided

primarily by AHAM and can be categorized into three areas: (1) the

accuracy of the simulation model; (2) the method in which the modeling

analysis was conducted; and (3) the selection of baseline models for

room air conditioners without louvered sides.

In comparing simulation results from the Department's computer

simulation model to test data gathered from four room air conditioner

models, AHAM demonstrated that there is a marked tendency for the

simulation model to overestimate system efficiency. It concluded that

the simulation model has the potential for making errors of 5 percent

or more, especially when extended well beyond the point where actual

correlative test data exists. (AHAM, No. 1 at 3.) Frigidaire and Sanyo

reinforced the AHAM's comments when they presented data demonstrating

that the simulation model estimated higher benefits for design options

than are realized in practice. (Frigidaire, No. 544 at 4; Sanyo, No.

771 at 10-12.)

The simulation model was extensively reviewed by the room air

conditioner industry. For the 1994 Proposed Rule, simulation results

were calibrated to manufacturer test data for all of the representative

baseline units modeled. The Department recognizes that when simulation

results are calibrated to a single manufacturer's test

[[Page 50130]]

data, it is possible that the model will yield errors of 5 percent or

more when used to simulate the performance of other manufacturers'

units. Where test data is not available, the Department expects to

continue to use the simulation model to estimate the efficiency

increases resulting from the incorporation of design options. When

manufacturer test data is provided, as in the case of subcoolers, the

Department will use it to adjust the simulation model.

AHAM commented that several errors were made in the simulation

modeling. The first pertains to compressor modeling and the fact that

actual compressor performance data was used only in the modeling of

baseline equipment. The Department derived performance data for more

efficient compressors by multiplying the motor input values from the

baseline compressor data by the ratio of the baseline and high-

efficiency compressor nominal energy efficiency ratios (EER.) This type

of analysis shows overall room air conditioner efficiency improvement

equal to 89 percent of the nominal compressor EER improvement. Limited

test data shows that the overall room air conditioner efficiency

increase is about 75 percent of the nominal compressor EER improvement.

AHAM advocated using actual compressor performance data for the

analysis of more efficient compressors but to limit maximum system

efficiency improvements to 75 percent of the nominal compressor EER

increase. It also stated that when deriving compressor coefficients for

input to the simulation model, the Department must use compressor

performance data that spans the entire range of evaporating and

condensing temperatures under which the compressor might operate.

Otherwise, incorrect input coefficients could be generated. (AHAM, No.

1 at 3-6 and AHAM, RAC No. 4 at Attachment 1 pg 1.)

The Department agrees with AHAM that actual compressor performance

data should be used to model the performance of compressors. Nominal

compressor performance is based on ratings at standardized temperature

conditions, and actual compressor performance may be significantly

different at actual room air conditioner operating conditions. Using

the nominal efficiency to compare the performance between two

compressors only provides the efficiency difference at the standardized

conditions. Using actual compressor performance data to model

compressor operation captures the effect that different operating

conditions have on room air conditioner performance. Thus, actual

compressor performance data, spanning the entire range of evaporating

and condensing temperatures in which the compressor might operate, was

used to model the performance of all the compressors analyzed for the

Final Rule. The Department disagrees with AHAM that system efficiency

improvements should be limited to 75 percent of the nominal compressor

EER increase. The basis for using compressor performance data is to

more accurately assess the system improvement due to more efficient

compressors. Placing a ceiling on the efficiency improvement eliminates

the possibility of gaining system EER increases due to more favorable

compressor operating conditions. As it turned out, most of the

compressors modeled as design options in the Final Rule analysis

yielded system efficiency increases that were equal to or less than 75

percent of the nominal compressor EER increase. Only one of the

compressors analyzed yielded a system efficiency increase significantly

above the AHAM's suggested 75 percent ceiling. This compressor was used

at standard level 5, which was found to be not economically justified.

According to AHAM, another error in the simulation modeling

concerns the use of superheat. It noted that the Department incorrectly

specified the input for superheat from manufacturer test data by using

the difference between the mid-evaporator temperature and a temperature

on the suction line. It claimed that the Department should have

adjusted the superheat input to the simulation model until the

difference between the averages of the simulated evaporator inlet and

outlet temperatures and the simulated suction line inlet and outlet

temperatures were equal to the test value. (AHAM, No. 1 at 5.)

The Department's method for specifying the superheat was in

accordance with recommendations made by AHAM in 1990. These

recommendations included making modifications to the simulation model

in order to account for the presence of an accumulator. The

modifications were based on treating the inlet to the accumulator as

the inlet to the compressor shell for rotary compressors. In order to

account for superheating occurring within the accumulator, the

simulation model was modified to include provisions to account for the

temperature and pressure increases that occur within the accumulator.

The location on the suction line where the temperature was measured was

at the accumulator inlet (i.e., the suction line outlet). The superheat

in the simulation model is defined as the difference between the

compressor shell inlet's refrigerant and saturation temperatures;

therefore, knowing that the suction line temperature was measured at

the accumulator inlet provided confidence in using it to specify the

superheat. Because the test data did not provide the accumulator

inlet's saturation temperature, the mid-evaporator temperature was used

as a close approximation of the evaporator saturation temperature,

which is also a close approximation for the compressor shell inlet

saturation temperature. Therefore, the Department believes it

appropriate to use the difference between the mid-evaporator and

accumulator inlet temperatures to specify the superheat. AHAM indicated

in its comments to the Draft Report that this method addresses its

concerns. (AHAM, RAC No. 4 at Attachment 1, pg. 1.)

In estimating room air conditioner efficiency increases resulting

from more efficient fan motors, AHAM commented that it was

inappropriate to use combined fan and fan motor efficiencies as input

to the simulation model. Rather than using efficiencies, it advocated

using fan motor power as an input as it asserts that room air

conditioner efficiencies will be overestimated by using fan and fan

motor efficiencies. (AHAM, No. 1 at 5.)

The simulation model was originally developed to model the

performance of central air conditioners. Manufacturers generally agreed

to this approach. However, some adjustments had to be made to model a

different air delivery system. For room air conditioners, the

evaporator and condenser fans are both driven by a single fan motor, as

opposed to central air conditioners, in which each fan is driven by its

own fan motor. For the room air conditioner model, the Department

decided to describe the air delivery system with combined fan and fan

motor efficiencies in order to account for the impact of evaporator and

condenser air-side pressure drop on fan motor power use. This modeling

scheme also assumed that the evaporator fan accounted for 40 percent of

the total fan motor power while the condenser fan accounted for the

remaining 60 percent. AHAM was in agreement with modeling the room air

conditioner's air delivery system by using a ``40/60 split'' on the fan

motor power. But due to this modeling scheme, only 60 percent of the

fan motor heat loss was added to the condenser air stream. All of the

heat loss from the fan motor should be added to the condenser air

stream as the motor resides in the outdoor section of the room air

conditioner. The Department

[[Page 50131]]

decided to change the simulation model in order to account for the fan

motor's full heat loss. In the Department's analysis for the 1994

Proposed Rule, simulation results were calibrated to test data for all

the baseline models. Because accounting for the full heat loss slightly

lowers the system efficiency, minor adjustments had to be made to the

power and capacity correction factors contained in the input files in

order to recalibrate the simulation results to the baseline model test

data. In AHAM's comments to the 1996 Draft Report, AHAM indicated that

this method addressed its concerns. (AHAM, RAC No. 4 at Attachment 1,

pg 1.)

AHAM claimed the simulation modeling analysis used incorrect power

consumption penalties to account for reversing valves and for no

louvers. With regard to reversing valves, AHAM noted that the TSD for

the 1994 Proposed Rule reports two different power consumption

penalties: 3 percent and 4 percent. AHAM noted that the Department's

simulation analysis actually calculates a power reduction value of 2.5

percent. AHAM recommended using a penalty of five percent when modeling

reverse cycle units with the simulation model. With regard to the power

consumption penalty used for units without louvered sides, AHAM claimed

that the value of 4 percent used in the Department's simulation

analysis does not account for the reduced airflow across the condenser

coil due to the non-louvered sides. Although it proposed no alternative

power penalty to account for non-louvered sides, it stated that the

condenser face area being modeled should be decreased because outdoor

air is drawn through the back of the unit rather than through louvered

sides, and thus less condenser area is available for heat exchange.

(AHAM, April 7, 1994, Transcript at 62-65.)

For the 1994 Proposed Rule, power consumption penalties to account

for reversing valves and to account for no louvers were applied only to

the compressor's power consumption. Because the power penalty is

assessed only to the compressor, the overall power increase for the

entire room air conditioner is always slightly smaller than the

reported power penalty value. The TSD for the Proposed Rule did

mistakenly report two different penalties for reversing valves. The

value that was actually used was 3 percent. The power penalty used to

account for non-louvered sides was 4 percent. A 5 percent power penalty

was used for the Final Rule to account for products with a reversing

valve. Because an alternative power penalty value was not proposed for

non-louvered sides, the Department retained the use of a 4 percent

power penalty. This 4 percent power penalty was assumed to account for

any degradation in performance due to drawing outdoor air directly

through the condenser coil. Thus, the modeled condenser face area was

not reduced.

In its comments to the 1996 Draft Report, AHAM states that although

the Draft Report indicates that power consumption penalties were used

in the simulation model, it appears (referencing Table 1.6 of the Draft

Report) that baseline data for actual models were used, and that these

results are not consistent with actual practice. (AHAM, RAC No. 4 at

2.) The Department did use the power consumption penalties in the

simulation model for the Draft Report. Table 1.6 of the Draft Report is

intended to show that the results produced by the simulation model are

close to the actual test data.

Both AHAM and Sanyo asserted that the Department selected baseline

models for ``through-the-wall'' units (units without louvered sides)

with efficiencies that were not representative of the class. They both

stated that baseline models were derived from models with louvered

sides, and thus, the analysis conducted for these products is

meaningless. Sanyo stressed that the largest capacity size within the

smallest enclosure for the particular product class of interest should

be selected as a representative baseline model. (AHAM, No. 1 at 19;

Sanyo, No. 771 at 6-10.)

In the analysis for the 1994 Proposed Rule, representative baseline

models for non-louvered and reversing valve classes were derived from

the baseline models that were selected for louvered classes. The

Department agrees with AHAM and Sanyo in that actual baseline units

should be used to represent the non-louvered and reversing valve

classes. Thus, the Department based its analysis of non-louvered and

reversing valve classes on modeling of actual baseline units. With

regard to non-louvered classes, manufacturer data were available only

for two of the existing five capacity classes; 6,000 to 7,999 Btu/h and

8,000 to 13,999 Btu/h. Thus, analyses were conducted only for the two

classes where manufacturer data were available. Manufacturer data were

also available for selecting representative baseline units for

reversing valve classes, with and without louvered sides, and

engineering analyses were conducted for both these classes.

Based on its recommended changes for improving the performance of

the engineering simulation model, AHAM re-ran the model for the five

capacity classes with louvered sides and without a reversing valve. For

all five classes, the efficiency levels determined by AHAM's simulation

analysis were significantly lower than the Department's proposed

efficiency standards. (AHAM, No. 1 at 26.) Using the version of the

simulation model that the Department used for its Proposed Rule

analysis, Sanyo conducted a simulation analysis for classes without

louvered sides. With its analysis, it also concluded that efficiency

gains were significantly below those that the Department demonstrated

were possible for classes without louvered sides. (Sanyo, No. 771.)

Like AHAM, Fedders also performed an efficiency analysis for the five

capacity classes with louvered sides and without a reversing valve. But

instead of using the Department's simulation model, it used test data

(and interpolated estimates based on test data) to project efficiency

increases. Fedders' results were similar to AHAM's in that the

efficiency levels that were calculated were significantly lower than

the Department's proposed standards for all five classes. (Fedders, No.

693 at Sec. 1, 1-6.)

Based on the comments received, DOE made a number of adjustments to

the simulation model, as described above, and changed the method in

which certain design options were analyzed. After these adjustments,

the Department's simulation results were close to those reported by

AHAM. For the five capacity classes being compared, these were the only

two classes for which DOE and AHAM had efficiency results that differed

by greater than 1 percent--the 6,000 to 7,999 Btu/h class and the

14,000 to 19,999 Btu/h class.

In the case of the 6000 to 7999 Btu/h class, the discrepancy

(approximately 3 percent) between AHAM's simulation results and the

Department's simulation results for the Final Rule can be attributed to

an error in the earlier simulation model. This error, which was present

in the simulation model that AHAM used and that the Department used in

its analysis for the Proposed Rule, was corrected for the Department's

Final Rule analysis. Thus, correcting this error in the version of the

simulation model used by the AHAM would yield a predicted efficiency

that would be closer to that estimated by the Department for the Final

Rule. The error related acceptable difference between the calculated

condenser exiting temperatures from the two subroutines--because the

acceptable difference was too low, the model

[[Page 50132]]

converged at solutions that produced condenser heat transfer

coefficients which were too small.

In the case of the 14,000 to 19,999 Btu/h class, the discrepancy

(approximately 3.5 percent) was primarily attributable to AHAM's method

of estimating efficiency improvements due to an additional design

option (condenser grooved tubes) that was analyzed by the Department

but not by AHAM. If the Department had not considered this design

option, the discrepancy would only be 0.6 percent.

In AHAM's comments to the 1996 Draft Report, AHAM stated that it

was ``satisfied with the efficiency analyses of models with side

louvers and without reverse cycle up to the application of the BPM fan

motor and the variable speed compressor'' and that after correcting for

the errors described in the preceding paragraphs, ``the correlations

would all be within an acceptable 1%''. (AHAM, RAC No. 4 at 2.)

With regard to Fedders' estimates, the Department's revised

efficiency estimates were still significantly different: discrepancies,

on average, were over 3.5 percent. Unfortunately, Fedders did not

provide detailed information on how it arrived at its estimates. Given

the close agreement with the results reported by AHAM, the Department

is comfortable with its revised simulation results.

In its comments to the Draft Report, AHAM stated that the ``fine

tuning of the simulation model has led to reasonably good

correlations'' for models with side louvers and with a reverse cycle.

However, AHAM stated that although the simulation model was calibrated

to baseline data for actual models without louvers and actual models

with a reverse cycle, ``the simulated effect of the applied design

options is not consistent with actual practice.'' AHAM also stated that

considerable time and effort would be required to ``get the same level

of correlation that was achieved for models with louvers and without a

reverse cycle.'' AHAM also states that the wide variability of results

when comparing simulation model efficiency results to AHAM's results

shows that there is a ``significant problem'' in simulating models with

reverse cycle. (AHAM, RAC No. 4 at 2-4.) In addition, with regard to

units with a reverse cycle, AHAM stated that ``poor correlation with

these units is most likely due to the unusual restrictions in the

refrigeration circuit due to the reversing valve and compromises made

to balance both the heating and the cooling of the unit.'' (AHAM, RAC

No. 4 at 4.) ACEEE and NRDC recommended in their joint comments that

``problems with the simulation models can be dealt with by examining

the efficiencies of units now on the market, in order to sanity check

the simulation model results.'' (ACEEE/NRDC, RAC No. 5 at 3.)

The Department agrees that its computer model may not accurately

simulate actual performance for models without louvers (classes 6-10)

or models with a reverse cycle (classes 11 and 12). Consequently, the

Department has relied more heavily on the comments in selecting

standards levels. For classes with a reverse cycle, the Department

chose standard levels which took into consideration the comments by

both the manufacturers and energy efficiency advocates. With regard to

the recommendation made by ACEEE and NRDC, the Department consulted the

AHAM directory when making decisions on the efficiency standards to set

forth in this rule.

4. Proposed Efficiency Standards

Support for proposed standards. Southern California Edison Company

(SCEC), ACEEE, Central Hudson Gas & Electric Corporation (CHGEC), and

Alabama Power Company (APC) all generally supported the Department's

proposed standards. ACEEE stated that the standards proposed in the

1994 Proposed Rule are supported due to the availability of products

with high efficiency levels in the marketplace. ACEEE stated that

according to AHAM's 1993 and 1994 directories, units with louvered

sides and without a reversing valve are available with efficiencies

exceeding 11.0 EER in the 6000 to 7999 Btu/h and 8000 to 13,999 Btu/h

product classes. In the 14,000-19,999 Btu/h product class, models are

available with efficiencies of 10.5 EER. The ACEEE asserted that even

if the Department underestimated the extra first cost of the proposed

standards by a factor of two, they would still be cost effective.

(ACEEE, No. 557 at 20-22.) CHGEC stated that for its service area, the

proposed standards would save approximately 103 kWh per unit for a

typical 8000 Btu/h size. (CHGEC, No. 601 at 1.) SCEC and APC generally

supported the rulemaking proposals. (SCEC, No. 14 at 1; APC, No. 696 at

20.)

Although the Department recognizes the comments supporting the

proposed standards, lower efficiency standards are being promulgated in

this Final Rule. Revisions made to both the engineering simulation

model and the method in which certain design options were analyzed,

based on public comment, resulted in lower efficiency standards being

selected for all product classes.

Proposed standard level 6. In addition to receiving comments in

support of the proposed standards, the NRDC commented that the

Department did not provide justifiable reasons for rejecting even the

higher efficiency standards in the 1994 Proposed Rule. NRDC's argument

included: (1) the Department's rejection of the higher standards

(described as standard level six in the 1994 Proposed Rule) based on

the standard level's long payback is legally unacceptable; (2) though

short-term return on equity is reduced by standard level six, the long-

term return is not significantly reduced; and (3) manufacturer cost

impacts are premised on the continuation of current practices for

utility rate design under which residential peak kilowatt-hours do not

carry a price premium. (NRDC, April 5, 1994, Transcript at 115-116.)

There are significant differences between the candidate standard

levels selected for the proposed rule and those levels selected for the

final rule. These differences are a result of revisions made to the

engineering analysis.

In response to NRDC's specific comments, the Department recognizes

that in determining whether a standard is economically justified, the

Secretary cannot consider the failure to meet the rebuttable

presumption criterion. EPCA, section 325(o)(2)(B)(iii), 42 U.S.C.

6295(o)(2)(B)(iii). However, the Department does consider energy cost

savings relative to incremental first cost. EPCA, section

325(o)(2)(B)(I)(II), 42 U.S.C. 6295(o)(2)(B)(I)(II). The Department

also considers both short run and long run return on equity as

important factors in determining the rule's impact on manufacturers. In

addition, the Department strives to fairly assess consumer cost

impacts, including sensitivity analysis of high and low State energy

prices.

Adverse effects of standards. The Department received several

comments regarding the adverse affects of promulgating the proposed

standards. The greatest concern of manufacturers, that heat exchanger

coils and cabinets would need to be expanded, at significant expense,

in order to meet the Department's proposed standards, was discussed

previously under comments pertaining to design options requiring

increased chassis sizes. Other manufacturer concerns included: (1) The

disparity in the proposed efficiency levels for class 1 (less than

6,000 Btu/h, with louvers and without a reversing valve) and class 2

(6,000-7,999 Btu/h, with louvers and without a reversing valve); (2)

the effect of higher efficiency

[[Page 50133]]

standards on the replacement market for ``through-the-wall'' units

(i.e., units without louvered sides) ; (3) the effect higher standards

would have on sales of units with reversing valves; (4) the impact on

the dehumidification capability of low capacity units; and (5) the

impact on low-income consumers.

The proposed standard of 11.1 EER for class 1 units was

significantly greater than the proposed standard of 10.3 EER for class

2 units. Both AHAM and Frigidaire claimed that this disparity in the

efficiency levels will result in significantly higher consumer costs

for class 1 units. They asserted that this disparity will eventually

eliminate class 1 units from the marketplace because consumers would

purchase less expensive class 2 units. They stated that eliminating low

cost class 1 units would adversely effect low income consumers. With

regard to energy consumption, for applications where class 1 units are

more suitable, they stated that class 2 units might run less to provide

the same amount of cooling, but their overall power consumption would

be higher because they would operate at a lower efficiency. For units

of equal efficiency providing cooling to environments with the same

sensible and latent loads, limited manufacturer test data indicated

that a class 2 unit (6,000 Btu/h capacity) consumes 6 percent more

power than a class 1 unit (5,000 Btu/h capacity.) In addition, both

AHAM and Frigidaire claimed that to offset humidity effects, class 2

units would probably be run with a lower thermostat setting resulting

in increased run times and increased energy use. Both commenters urged

the Department to set standard levels for class 1 units that are no

greater than the standards that are set for class 2 units. (AHAM, No. 1

at 18-19; Frigidaire, No. 544 at 6-9.)

ACEEE also noted the disparity in the proposed efficiency levels

for class 1 and class 2 units. It noted that class 3 units (8,000 to

13,999 Btu/h) have a significantly higher efficiency standard than

class 2 units. ACEEE commented that promulgating a significantly lower

standard for class 2 units would likely result in manufacturers

concentrating a greater fraction of shipments in this size range,

leading to lower than expected energy savings from the proposed

standards. The ACEEE urged the Department to raise the standard for

class 2 units to 11.0 or 11.1 EER. ACEEE claimed this level is

``technically feasible according to the Department's analysis,'' citing

that the top-rated model in the market in this capacity range has an

11.0 EER. ACEEE believed that because the DOE life-cycle cost analysis

showed only a slight increase in life-cycle cost going from an EER of

10.25 to 10.74 for this capacity range, a ``small additional step to an

EER of 11.0--11.1 should not have much of an impact on LCC either.'' It

also urged the Department to raise the standard for the 6000 to 7999

Btu/h product class without side louvers to the same levels being

proposed for the less than 6000 Btu/h and 8000 to 13,999 Btu/h product

classes. (ACEEE, No. 557 at 22.)

The Department disagrees that ACEEE's extrapolation of the life-

cycle cost analysis of the 1994 Proposed rule indicates that an

increase to 11.0--11.1 EER should have little impact on life-cycle

cost. Moreover, the reanalysis provided in the Draft Report resulted in

efficiency levels for classes 1 and 2 being approximately the same.

AHAM indicated in its comments to the Draft Report that these results

addressed its concerns. (AHAM, RAC No. 4 at Attachment 1, pg 3.) In

addition, for the final rule, the Department has selected standards for

class 1 and class 2 that are equal. ACEEE and NRDC also support these

standard levels. (ACEEE/NRDC, RAC No. 14 at 3.)

AHAM, manufacturers, and real estate organizations commented that

the proposed efficiency standards would obsolete the replacement market

for ``through-the-wall'' units (i.e., units without louvered sides.)

Because of the unavailability of 11.5 to 12.0 EER compressors, chassis

sizes would need to be increased to meet the proposed efficiency

standards. But because of the overall size restrictions due to

``through-the-wall'' sleeves already in service, chassis sizes cannot

be increased without obsoleting the existing sleeves. If existing wall

openings are expanded to accommodate larger units, retrofit costs are

estimated to be between $250 and $500. These commenters argue that the

proposed standards would force the discontinuation of higher capacity

systems as only smaller capacity units would be able to fit into

existing sleeve openings. (AHAM, No. 1 at 19; Given & Spindler

Companies (G&S), No. 302 at 1-2; Frigidaire, No. 544. at 5; Institute

of Real Estate Management (IREM), No. 553 at 7; Sanyo, No. 771 at 3-6;

Friedrich Air Conditioning Co. (Friedrich), April 7, 1994, Transcript

at 77-80.) Both IREM and G&S requested that the Department exempt

``through-the-wall'' units because of the undue burden upon owners who

will be forced to make retrofit changes without any financial

compensation. (G&S, No. 302 at 1-2; IREM, No. 553 at 7.) Sanyo stated

that the efficiency levels proposed in the 1994 Proposed Rule would

force higher capacity units to be discontinued. (Sanyo, No. 771 at 3.)

The AHAM presented data demonstrating that existing models meeting the

current efficiency standards already employ all available design

options. The AHAM stated that any increase in efficiency can only be

accomplished by increasing chassis size or by further decreasing

cooling capacity. (AHAM, No. 1 at 20.) Frigidaire stated that above

8,000 Btu/h, any increase in the current standard ``will result in a

lower BTUH capacity, thus reducing the utility of this product

category.'' Frigidaire notes that in order ``to comply with the 1990

Energy Standards, we were forced to reduce the capacity in this product

class from 13,500 BTU to 10,700 BTU.'' (Frigidaire, No. 544 at 5.) In

its comments to the 1996 Draft Report, AHAM reiterated the industry's

struggle to achieve the current standards in the largest capacity

models which has resulted in the reduction of the maximum capacity

available. (AHAM, RAC No. 4 at 4.) Both the National Apartment

Association (NAA) and the National Multi Housing Council (NMHC)

requested that the Department adopt an efficiency standard for units

without louvered sides that takes into consideration the adverse impact

upon the multi-family housing industry. (G&S, No. 302 at 2; IREM, No.

553 at 7.) Because the multi-family housing industry predominantly uses

air conditioner units without louvered sides, NAA and NMHC are

concerned about the impact of increased cabinet size (due to higher

efficiency standards) on these ``through-the-wall'' units.

The ACEEE opposed exempting ``through-the-wall'' units from more

stringent standards. It stated that such an exemption would create a

loophole that could result in a significant reduction in energy

savings. It believed that manufacturers should be able to produce these

units using the same or similar components used in louvered-type units.

Through gains in economy of scale, costs with maintaining different

product lines for models with and without side louvers could be

avoided. (ACEEE, No. 557 at 23.) ACEEE and NRDC are particularly

concerned about loopholes if standards are not increased for units

below 14,000 Btu/h. (ACEEE/NRDC, RAC No. 5 at 3.) In February 1997,

ACEEE and NRDC urged the Department to raise the standard for class 8

(units without louvers, without a reverse cycle, and 8,000--13,999 Btu/

h) to 8.7 EER in an effort to reduce the likelihood of a loophole. In

addition, they stated that according to the data provided by AHAM

(AHAM, RAC No. 9 at Attachment 1), the 1994 sales weighted average for

this class is 8.73

[[Page 50134]]

EER. (ACEEE/NRDC, RAC No. 14 at 3.) AHAM stated that these concerns are

based ``on the incorrect view that these products are essentially the

same except for the presence of side louvers.'' AHAM states that the

elimination of side louvers causes extensive changes that result in ``a

significant loss of efficiency for the same capacity.'' (AHAM, RAC No.

6 at 2.) Furthermore, AHAM stated that increasing the standard for

class 8 would eliminate higher capacity units, causing harm to building

owners and consumers, and would ``violate NAECA's safe harbor rule in

Section 325(n)(4).'' (AHAM, RAC No. 16 at 4.)

In its comments to the 1994 Proposed Rule NRDC was concerned that

the practice of using small sleeves may amount to a permanent

constraint on how far energy efficiency can be increased. It suggested

that the Department analyze what fraction of the market cannot accept

design options that increase sleeve size. Then the Department should

determine the economic impact of replacing design options that do

require increased size with other less cost-effective options for that

fraction of the market that cannot adapt. NRDC also suggested that the

Department consider adopting a second tier of efficiency standards

which would be available for states to adopt voluntarily through

building codes. This way, room air conditioners could be designed to

the optimum level for the new construction market without imposing

unreasonable costs on the replacement market. (NRDC, No. 55 at 27.)

The Department agrees with manufacturers and real estate

organizations that added retrofit costs would be necessary for units

which require larger sleeves and, as a result, larger wall openings.

Thus, for units without louvered sides, an additional installation cost

of $375 is assumed for design options which require a larger chassis

(i.e., for increased evaporator and condenser face areas.) The

Department was not provided with the necessary information to determine

the percentage of existing sleeves which could not accept larger

chassis sizes. Thus, the added retrofit cost of $375 was assumed to

apply to all units requiring a chassis size change. In addition, since

the percentage of units being used in new construction is believed to

be small, all units were assumed to incur the added retrofit cost,

regardless of application. The Department examined the 1997 AHAM

Directory. It indicates that for higher capacity models (9,000 Btu/h or

more), only one manufacturer currently produces units which could meet

the advocates recommendation of 8.7 EER, despite the fact that this

value is the 1994 shipment weighted average for this class. The

Department agrees that there is reason to believe that increasing

standards for units without louvers and without reverse cycle may

result in eliminating higher capacity units from the market. Thus, the

Department will not increase standards for ``through-the-wall'' units

of 8,000 Btu/h capacity or more in today's rule. These standard levels

minimize or eliminate the need to increase chassis size. Consequently,

the Department does not believe the multifamily housing industry will

be negatively impacted.

As for the advocates concern over possible loopholes, the

Department intends to monitor market trends for these classes and will

consider these trends during its next review of room air conditioner

standards. Regarding NRDC's suggestion that the Department adopt a

second tier standard for states to adopt voluntarily through building

codes, in accordance with the legislation, a recommendation for a

second tier standard for adoption through voluntary building codes must

be done separately from manufacturing standards. However, because the

``through-the-wall'' units account for only about one-tenth of air

conditioner energy use and because only a fraction of these units are

in new construction, the Department does not believe this measure is

warranted.

In their comments to the 1994 Proposed Rule, AHAM and Whirlpool

also expressed that, as a result of setting standards too high for

units with a reversing valve, more electric resistance heat models will

be sold because of their significantly lower cost. They stated that

this will result in an overall increase in energy consumption. (AHAM,

No. 1 at 21; Whirlpool, April 7, 1994, Transcript at 103-105.) The

standards for units with a reverse cycle set forth in today's rule are

significantly lower than those standards proposed in the 1994 Proposed

Rule, so this concern should be mitigated.

Fedders claimed that energy consumption due to reduced

dehumidification is adversely affected by the standard levels proposed

in the 1994 Proposed Rule for class 1 through class 3. Fedders

presented calculations demonstrating that units meeting the proposed

standard levels will consume more energy than units meeting existing

efficiency standards. Fedders stated that units meeting the proposed

standard levels will need to operate longer in order to dehumidify as

effectively as units meeting the existing standards. (Fedders, No. 693

at 1-5, Sec. 2.)

Fedders' claims of longer run times for more efficient units are

based on its estimates of the dehumidification capability of existing

minimum efficiency units and those which comply with the Proposed

Rule's proposed efficiency standards. Fedders' dehumidification data

for units at the proposed efficiency levels were based on historical

test data which were extrapolated to the proposed levels. The

Department's engineering simulation model indicated that the proposed

efficiency standards did not significantly reduce the dehumidification

capability of the units which were modeled. The Department has

questions about Fedders' assumptions used to calculate room air

conditioner run times. For example, although Fedders acknowledges that

sizing recommendations for room air conditioners are dependent on such

things as building construction, window types and insulation levels,

its cooling load calculations are based on a single room size and a

single set of initial indoor room conditions. Most importantly, because

the standards promulgated in this final rule are significantly lower

than those proposed in the 1994 Proposed Rule, the dehumidification

capabilities should no longer be in question.

One of the country's largest retailers, the Sears, Roebuck and

Company (Sears), asserted that the standards proposed in the 1994

Proposed Rule impose disproportionate hardships on low income consumers

as most room air conditioner consumers have lower than average incomes.

Whirlpool substantiates this claim by presenting data on the income

distribution of typical room air conditioner purchasers. (Sears, April

7, 1994, Transcript at 115; Whirlpool, No. 391A at 1-2.)

The standards set forth in the final rule will have substantially

less impact on purchase price than those standards proposed in the 1994

Proposed Rule and will have shorter payback periods. For example, class

1 has an approximate first cost increase of $10, and a payback period

of approximately 2 years, satisfying the rebuttable presumption

criteria for economical justification. The Department does not believe

the standards set forth today will have a substantial negative impact

on low income consumers.

Efficiency Standards Recommendations. Several commenters concerned

about adverse effects of promulgating the efficiency standards proposed

in the 1994 Proposed Rule recommended to DOE alternative levels

[[Page 50135]]

at which to set the standards for room air conditioners. For classes

with louvered sides and without a reversing valve, Frigidaire

recommended the following efficiency standards: 9.0 EER for the less

than 6000 Btu/h class, 9.5 EER for the 6000 to 7999 Btu/h class, 9.5

EER for the 8000 to 13,999 Btu/h class, 9.5 EER for the 14,000 to

19,999 Btu/h class, and 8.5 EER for the greater than 20,000 Btu/h

class. (Frigidaire, No. 544 at 10.) In its comments to the 1994

Proposed Rule, Fedders called for consolidating the three smallest

capacity classes into a single class and setting the efficiency

standard at 10.0 EER. For the two largest capacity classes, Fedders

agreed with the Department's proposed standards (11.1 and 9.8 EER).

(Fedders, April 7, 1994, Transcript at 120-122.) The CEC recommended a

single efficiency standard for all classes with louvered sides and

without a reversing valve. It recommended setting the efficiency

standard based on the level which the Department proposed (11.0) for

the most popular class (i.e., the 8000 to 13,999 Btu/h class.) (CEC,

No. 539 at 2,3.)

For classes without louvered sides and without a reversing valve,

AHAM, Frigidaire, and Sanyo recommended that the current five capacity

classes be consolidated into two classes: units less than 8000 Btu/h

and units greater than or equal to 8000 Btu/h. For the less than 8000

Btu/h class, AHAM, Frigidaire, and Sanyo all recommended setting the

efficiency standard at 9.0 EER. For the greater than or equal to 8000

Btu/h class, they all recommended setting the standard at 8.5 EER. AHAM

presented data demonstrating that existing models meeting the current

efficiency standards already employ all available design options. They

stated that any increase in efficiency can only be accomplished by

increasing chassis size or by further decreasing cooling capacity.

(AHAM, No. 1 at 20; AHAM RAC No. 4 at 1-2; Frigidaire, No. 544 at 5;

Sanyo, No. 771 at 3.) Friedrich recommended that units without louvered

sides be exempt from efficiency regulation. (Friedrich, April 7, 1994,

Transcript at 84.) The CEC recommended a single efficiency standard for

all classes without louvered sides and without a reversing valve. The

Commission recommended setting the efficiency standard based on the

level which the Department proposed (10.7 EER) for the most popular

class (i.e., the 8000 to 13,999 Btu/h class). (CEC, No. 539 at 2,3.)

For classes with a reversing valve, AHAM stated that the efficiency

of a reverse cycle unit in the cooling mode is theoretically less than

the efficiency for a cooling-only model due to the additional pressure

drop caused by the reversing valve and inefficiencies created by the

refrigerant charge being adjusted for an acceptable balance between

cooling and heating performance. AHAM presented data demonstrating that

the average reduction in efficiency due to a reversing valve is 0.42

EER. In order to cover the majority of reverse cycle units, AHAM

recommended setting a standard for reverse cycle units which is 0.5 EER

less than the standard for a comparable cool-only model with or without

louvered sides. (AHAM, No. 1 at 20, 21.) Both Sanyo and Whirlpool also

recommended setting the same type of standard. (Sanyo, No. 771 at 3;

Whirlpool, April 7, 1994, Transcript at 103-105.) The CEC proposed

maintaining the current classification for units with a reversing

valve; one class for units with louvered sides and another class for

units without louvered sides. The CEC agreed the efficiency levels

proposed by the Department for reverse cycle units. (CEC, No. 539 at

2,3.)

On April 23, 1996, ACEEE and NRDC sent a letter to AHAM with the

following table of proposed standard levels (ACEEE/NRDC, RAC No. 3 at

3.):

------------------------------------------------------------------------

Class Standard level

------------------------------------------------------------------------

Units without reverse cycle and with louvered

sides:

Capacity less than 20,000 Btu/h.......... 10.0 EER.

Capacity 20,000 Btu/h and more........... 9.0 EER.

Units without reverse cycle and without 9.0 EER.

louvered sides.

Slider/casement and casement-only units...... 9.0 EER.

Units with reverse cycle, all capacities..... 0.5 EER less than the

standard for comparable

cool-only model.

------------------------------------------------------------------------

In its comments to the 1996 Draft report, AHAM proposed the

following standards (AHAM, RAC No. 6 at 2):

------------------------------------------------------------------------

Class Standard level

------------------------------------------------------------------------

Units without reverse cycle and with louvered

sides:

Capacity less than 20,000 Btu/h.......... 9.5 EER.

Capacity 20,000 Btu/h and more........... 8.5 EER.

Units without reverse cycle and without

louvered sides:

Capacity less than 8,000 Btu/h........... 9.0 EER.

Capacity 8,000 Btu/h or more............. 8.5 EER.

Units with reverse cycle, with louvers....... 8.5 EER. ***

Units with reverse cycle, without louvers.... 8.0 ERR.***

Casement-only................................ 8.7 EER.

Casement-slider.............................. 9.5 EER.

------------------------------------------------------------------------

*** AHAM would prefer to set the standard for reverse cycle units 0.5

EER less than the standard for its ``cool-only'' counterpart. This

recommendation results in ten classes for reverse cycle units. Because

DOE did not support ten classes for reverse cycle units, AHAM stated

that the standard should be set in reference to the highest capacity

class. For example, if the standard for models without reverse cycle,

without louvers, 20,000 Btu/h or more were set at 8.5 EER, then the

standard for units with reverse cycle, without louvers, 20,000 Btu/h

or more should be set at 8.0 EER. (AHAM, RAC No. 6 at 2-3.)

Following the meetings in late September 1996, ACEEE modified its

recommendation to the following standards (ACEEE/NRDC, RAC No. 5 at 4-

5)

[[Page 50136]]

------------------------------------------------------------------------

Class Standard

------------------------------------------------------------------------

Without reverse cycle and with louvered sides 9.7 EER.

less than 6,000 Btu/h.

Without reverse cycle and with louvered sides 9.7 EER.

6,000 to 7,999 Btu/h.

Without reverse cycle and with louvered sides 9.8 EER.

8,000 to 13,999 Btu/h.

Without reverse cycle and with louvered sides 9.7 EER.

14,000 to 19,999 Btu/h.

Without reverse cycle and with louvered sides 8.5 EER.

20,000 or more Btu/h.

Without reverse cycle and without louvered 9.0 EER.

sides less than 14,000 Btu/h.

Without reverse cycle and without louvered 8.5 EER.

sides 14,000 or more Btu/h.

With reverse cycle and with louvered sides... 9.0 EER.

With reverse cycle, without louvered sides... 8.5 EER.

Casement (Casement-only and Casement-slider). 9.5 EER.

------------------------------------------------------------------------

For classes without louvered sides, ACEEE and NRDC stated in their

November 1996 comments that they were willing to accept 8.5 EER for

capacities of 14,000 Btu/h or more. However, ACEEE and NRDC emphasized

their recommendation of 9.0 EER for the 8,000--13,999 Btu/h capacity

class, stating that: this EER is the minimum life cycle cost point

according to the Draft Report; the 1994 sales weighted average of 8.73

EER approaches this recommendation; and 20 percent of 1996 models in

this class meet or exceed this level according to the March 1996 AHAM

Directory. They were concerned that AHAM's 8.5 EER recommendation could

``create a loophole in that units without louvered sides at 8.5 EER

would cost manufacturers less than units with louvered sides at 9.5 EER

($240 vs. $263 according to the DOE draft analysis).'' (ACEEE/NRDC, RAC

No. 5 at 3.) In its comments to the Draft Report, AHAM states that

there is a significant cost and energy efficiency differential between

models with and without side louvers. (AHAM, RAC No. 6 at 2.) In

February 1997, ACEEE and NRDC urged the Department to raise the

standard for class 8 to at least 8.7 EER. (ACEEE/NRDC, RAC No. 14 at

3.)

As discussed earlier, although manufacturers currently do not

produce units in two of the existing five capacity classes, the

Department has retained the five capacity-based classes. The Department

conducted analyses only for the two classes for which manufacturer data

were available (the 6,000 to 7,999 Btu/h and the 8,000 to 13,999 Btu/h

classes.) In this Final Rule, the Department has applied the same

efficiency standard (9.0 EER) to the 6,000 to 7,999 Btu/h class and the

less than 6,000 Btu/h class. The efficiency standard for the 8,000 to

13,999 Btu/h class (8.5 EER) is also applied to the 14,000 to 19,999

Btu/h class and the 20,000 Btu/h or more class. According to 1997 AHAM

Directory, the highest capacity ``through-the-wall'' unit currently

manufactured has a capacity of 12,500 Btu/h, and only one manufacturer

currently makes units at a capacity of 9,000 Btu/h or higher which meet

the 8.7 EER standard proposed by ACEEE/NRDC. On this basis, the

Department has determined that raising this standard is likely to

result in higher capacity models being withdrawn from the market to the

disbenefit of consumers.

With regard to the comment that units without louvered sides at 8.5

EER would cost manufacturers less than units with louvered sides at 9.5

EER, ACEEE and NRDC appear to refer to the values found in tables 1.12

and 1.16 in the Draft Report. The two units being compared have

different capacities; therefore a direct cost comparison is not

appropriate. However, the Department shares the general concern about

the possibility that differences in standard levels for different

classes may cause shifts in product use and sales, and as stated

previously, the Department intends to monitor market trends for these

classes. If it appears that products without louvers are used in lieu

of units with louvers because of differences in energy efficiency

standards, the Department will consider the need to set comparable

standards during its next review of room air conditioner standards.

In their comments to the Draft Report, ACEEE and NRDC recommend a

9.0 EER for reverse cycle units with louvers and an 8.5 EER for reverse

cycle units without louvers. They stated that these levels are well

below the minimum life-cycle cost point of the Draft Report.

Furthermore, they state that a third of the 1996 reverse cycle units

with louvers and 80 percent of the 1996 reverse cycle units without

louvers meet these levels. The advocates also note that the only

reverse cycle unit in the 1996 AHAM directory above 20,000 Btu/h has a

9.0 EER. (ACEEE/NRDC, RAC No. 5 at 3.) In addition, they are concerned

about ``loopholes'' which may result if the standards are not raised.

(RAC, No. 12 at 1.) AHAM counters that a loophole would not be created

because the cost of building a unit with a reverse valve is ``quite

significant.'' (AHAM, RAC No. 6 at 3.) The energy advocates also state

that the Department's analysis appears to only evaluate cooling energy

savings and not heating energy savings. (ACEEE/NRDC, RAC No. 5 at 2.)

In response to comments, DOE has split classes 11 and 12. AHAM,

NRDC, and ACEEE all recommended setting the standards for reverse cycle

units at 0.5 EER less than their cool-only counterparts. (ACEEE/NRDC,

RAC No. 3 and AHAM, No. 1 at 21.) For units with reverse cycle and

louvered sides, the energy efficiency advocates believe an EER of 9.0

is acceptable. (ACEEE/NRDC, RAC No. 5 at 5.) AHAM also finds this level

to be acceptable for units with capacities less than 20,000 Btu/h.

However, for units at 20,000 Btu/h or more, AHAM argues that the

standard should not be higher than the standard for its ``cool-only''

counterpart. (AHAM, RAC No. 6 at 3.) The Department agrees. By

splitting class 11 at 20,000 Btu/h, the Department can raise the

standard for most of the units with reverse cycle and with louvers to

9.0 EER, without raising the standard for units of capacities of 20,000

Btu/h or more above the 8.5 EER of its cool-only counterpart.

Similarly, the Department has split class 12 and set the standard

for units less than 14,000 Btu/h at 8.5 EER while keeping the standard

for units of 14,000 Btu/h or more at 8.0 EER. This split is largely

consistent with the recommendations of ACEEE, NRDC, and AHAM for a 0.5

EER differential between reverse cycle units and their ``cool-only''

counterparts for units without louvers, with the exception of units in

the 8,000-13,999 Btu/h capacity range for which there is no

differential. According to the 1997 AHAM directory, only one model with

reverse cycle and without louvers in this capacity range does not meet

an 8.5 EER. In response to the advocates question as to why the

Department's analysis only evaluates cooling energy savings and not

heating energy savings, the Department does not evaluate heating

savings because the test procedure is unable to account for the heating

energy savings.

[[Page 50137]]

In their February 1997 comments to the notice reopening the comment

period, ACEEE/NRDC stated that establishing separate classes with

weaker standards for higher capacity units with a reverse cycle is

unnecessary because all currently existing models at these capacity

levels meet their recommended standards, without splitting the classes.

(ACEEE/NRDC. RAC No. 14 at 3.) Although all currently existing models

with louvers and with a reverse cycle at 20,000 Btu/h or more meet a

9.0 EER, the Department does not believe new models entering the market

should be required to meet a standard higher than the standard for a

unit without a reverse cycle. In addition, the Department recognizes

that no models currently exist with a reverse cycle and without louvers

at 14,000 Btu/h or more; however, the Department believes that it

should allow manufacturers the opportunity to design units without

louvers and with a reverse cycle at higher capacities, and the evidence

indicates that manufacturers could not meet a standard greater than 8.0

EER at capacities of 14,000 Btu/h or more. Furthermore, in April 1996,

the advocates supported AHAM's recommendation to make the standard for

reverse cycle units 0.5 EER less than the standard for its cool-only

counterpart. (ACEEE/NRDC, RAC No. 3 at 3.) This recommendation would

create 10 classes for reverse cycle room air conditioners. Thus, the

Department questions why the advocates suggest that promoting only four

classes for reverse cycle units is superfluous.

AHAM stated that casement-type units are already using all

available design options and are limited in size because of their

applications. (AHAM, No. 1 at 22.) In its comments to the Draft Report,

AHAM recommended efficiency standards of 9.5 EER for slider/casement

units and 8.7 EER for casement-only units. (AHAM, RAC No. 6 at 2.) In

its comments to the 1994 Proposed Rule, Frigidaire recommended a

standard of 9.0 EER for slider/casement units. (Frigidaire, No. 544 at

6.) Because the 1994 Proposed Rule did not propose standards for

casement-type units, ACEEE, CEC, NRDC, and the New York State Energy

Office (NYSEO) urged the Department to collect the necessary data in

order to perform an analysis and set efficiency standards for these

units. ACEEE and NRDC stated that if data is not available to perform

an analysis, standards should be set for casement-type units that are

equivalent to those for typical room air conditioners. NRDC added that

the Department is prohibited under NAECA from reducing the stringency

of energy efficiency standards. The CEC asked the Department to clarify

whether States may adopt efficiency standards for casement-type classes

without preemption or whether another standard level applies to these

products until the Department adopts a separate level. (ACEEE, No. 557

at 23; CEC, No. 539 at 3; NRDC, April 5, 1994, Transcript at 116-117;

NYSEO, June 8, 1994, Transcript at 18-19.) The Department considers

casement-type units to be air conditioners. Therefore, these units are

subject to the currently applicable standards based on unit capacity

and the presence or absence of louvered sides and a reverse cycle.

In their February 1997 comments, ACEEE and NRDC stated that a

special class set aside for one casement-only model in existence is not

necessary. They are concerned that a casement-only unit at an 8.7 EER

will be less expensive to produce than a ``standard'' unit at 9.7 EER.

They believe this cost disparity would cause manufacturers to

capitalize on this niche class. (ACEEE/NRDC, RAC No. 14 at 2.) AHAM

counters that casement units are expensive relative to their capacity

and that there would be no economic incentive to exploit this class.

Furthermore, casement-only units add a unique utility not provided by

casement-slider units. (AHAM, RAC No. 16 at 3.) In addition, in

February 1997, Friedrich provided information regarding the relative

costs of casement room air conditioners as compared to ``standard''

models with side louvers and without a reverse valve. This information

shows that casement-only and casement-slider room air conditioners are

significantly more expensive than units that do not meet the size

constraints of casement room air conditioners. (RAC No. 18.) Therefore,

the Department has found no economical advantage to using casement-type

units at lower energy efficiency ratings for standard room air

conditioner applications. Thus, the Department has selected separate

classes for casement room air conditioners. DOE has selected the

efficiency standard recommended by AHAM, ACEEE, and NRDC for casement-

slider units (9.5 EER) (AHAM, RAC No. 6 at 2 and ACEEE/NRDC, RAC No. 5

at 5) and the standard recommended by AHAM for casement-only units (8.7

EER). (AHAM, RAC No. 6 at 2.) However, due to the energy efficiency

advocates' concern about the possibility of ``loopholes,'' the

Department will monitor market trends for these classes. If it appears

that casement units are used in lieu of ``standard'' units because of

differences in energy efficiency standards, the Department will

consider the need to set comparable standards during its next review of

room air conditioner standards.

AHAM stated that its recommended standards would result in

meaningful energy savings but would alleviate the economic burden on

manufacturers. AHAM states that in light of the economic burden of

chassis size increases, the cumulative burden of other rulemakings, and

the relatively modest energy use of room air conditioners that ``more

stringent standards than that proposed by industry would be

unreasonable and unjustified.'' (AHAM, RAC No. 6 at 1.)

The standards established in today's rule are similar to the

standards recommended by AHAM. The Department selected slightly higher

standards for the first four classes. AHAM's primary concern was the

cost of increasing chassis size. Because the standard levels the

Department has selected for the first five classes are based on the

life cycle cost minimums when the cost of increasing chassis size is

prorated, the Department believes the cost impact is reduced.

5. Other Comments

Effective date of standards. Commenting on the 1994 Proposed Rule,

Fedders proposed accelerating the effective date from January 1st to

August 1st. It claimed this would prevent manufacturers from producing

large quantities of less efficient units during the months of August

through December. (Fedders, April 7, 1994, Transcript at 123-124.)

AHAM urged the Department to set an effective date of October 1,

2000, in order to coordinate with manufacturing cycles. AHAM stated

that production begins in August or September and runs through June or

July. AHAM stated that an arbitrary effective date of 3 years from the

date of the rule, and likely in the middle of a manufacturing season,

would cause severe economic hardships on manufacturers which are not

accounted for in the manufacturing impact analysis. (AHAM, RAC No. 16

at 3.)

The Department agrees, due to the unique seasonal nature of room

air conditioners, the effective date should be coordinated with

manufacturing cycles. Thus, this rule will take effect on October

1,2000.

Units consuming less than 500 watts. Commenting on the 1994

Proposed Rule, Fedders recommended that room

[[Page 50138]]

air conditioners consuming less than 500 watts be exempted from

regulation. In support of this recommendation, it stated that a 3000

Btu/h capacity unit at an efficiency of 8.0 EER consumes 375 watts

compared to a 5000 Btu/h capacity unit at 11.1 EER that consumes 450

watts. Fedders argued that this exemption would encourage development

of units that are smaller and consume less energy and resources.

(Fedders, April 7, 1994, Transcript at 122-123.) AHAM, Frigidaire,

NRDC, and the ACEEE all opposed the Fedders' recommendation. AHAM

disagreed with Fedders' claim that as many as two-thirds of the rooms

in which 5000 Btu/h capacity units are installed could be adequately

cooled with units as small as 3000 Btu/h. AHAM saw no reason that

smaller units should be given an advantage by being exempted from a

standard and ``strenuously disagreed with Fedders' proposed exemption

for models of less than 500 watts.'' (AHAM, No. 1 at 23 and AHAM, RAC

No. 4 at Attachment 1, pg 4.) Frigidaire stated that the recommendation

by Fedders is counterproductive to saving energy as, under it, low

capacity units of low efficiency will be introduced into the

marketplace. (Frigidaire, No. 544 at 11.) The NRDC agreed with the

motivation behind Fedders' suggestion but did not agree with the

specifics of the recommendation as it would allow the creation of a new

market driven entirely by low first cost. NRDC suggested that the

Department consider a lower standard for a product class below 4000

Btu/h in capacity based on comparable criteria to the standard set for

the below 6000 Btu/h class. (NRDC, No. 55 at 28.) The ACEEE opposed the

Fedders' recommendation as it believes it could lead to widespread use

of inefficient smaller capacity units. (ACEEE, No. 557 at 22.)

The Department agrees with both AHAM and ACEEE that room air

conditioners which consume less than 500 watts should not be exempt

from efficiency regulation. The Department recognizes that small

capacity units may draw less power than larger capacity systems. But

the Department does not agree with Fedders' claims that, for units in

the less than 6000 Btu/h class, small capacity units will consume less

energy than more efficient, larger capacity systems. In creating a

separate product class for units with capacities below 6000 Btu/h, the

Department has recognized that small capacity units are used

differently than units in larger capacity classes. Applications for

small capacity units tend to be for small rooms where the cooling load

is relatively low. To further differentiate the less than 6000 Btu/h

class by capacity would require field tests demonstrating that there

are applications which are suitable specifically for units with

extremely small capacities. Such field data has not been presented.

Phase out of HCFC-22. With concern that the phase out 4

of HCFC-22 (the refrigerant used by all room air conditioners) might be

accelerated, AHAM recommended, in its comments to the 1994 Proposed

Rule, that the Department promulgate a second tier of standard levels

for HCFC-free room air conditioners. AHAM stated that some replacement

refrigerants show a drop in efficiency of 10 percent. AHAM proposed

that the second tier be set initially at 10 percent less than the

efficiency standards for room air conditioners using HCFC-22. AHAM

proposed that second tier of standards would be effective upon the

phase-out date of HCFC-22 and would not be available if the HCFC-22

phase out date is not accelerated. (AHAM, No. 1 at 22,23.) Because

compressor testing indicates that alternative refrigerant blends will

decrease efficiency, Matsushita commented that any efficiency standards

promulgated for room air conditioners should apply only to units

charged with HCFC-22. (Matsushita, April 7, 1994, Transcript at 91-92.)

Frigidaire urged the Department to consider possible energy penalties

for HCFC-22 alternative refrigerants. (Frigidaire, No. 544 at 11.) NRDC

did not support creating less stringent standards for room air

conditioners using alternative refrigerants. NRDC believed that units

with new refrigerant alternatives can attain the same efficiency level

as units using HCFC-22. NRDC suggested that the Department collaborate

with the Environmental Protection Agency on decisions regarding the

phase out of HCFCs. Because the Department must promulgate another

rulemaking before a phaseout would occur, NRDC stated that the phase

out date of HCFC-22 is not within the period of applicability for room

air conditioner efficiency standards. It urged that the Department

should not plan around a phase out requirement that does not exist.

(NRDC, No. 55 at 27,28.) ACEEE stated that alternative refrigerants,

such as AZ-20, have been demonstrated to increase room air conditioner

efficiency as compared to HCFC-22. (ACEEE, No. 557 at 21.)

---------------------------------------------------------------------------

\4\ The EPA's final rule accelerating the phaseout of ozone-

depleting substances bans the production and consumption of virgin

HCFC-22 unless it is used as feedstock or in equipment manufactured

before January 1, 2010. The final rule also bans the production and

consumption of HCFC-22 on January 1, 2020, except for limited

exemptions specified by statute. 60 FR 24970 (Wednesday May 10,

1995).

---------------------------------------------------------------------------

In 1996, Fedders stated it has concern over replacement

refrigerants. Fedders commented that the Montreal Protocol may require

phase-out sooner than the current phaseout date of 2010. Fedders stated

that the industry will be required to do extensive retooling if the new

standards cannot be met with replacement refrigerants. Furthermore,

Fedders stated that the U.S. is ``dangerously close to the legal caps

of HCFC chemicals.'' Fedders was concerned ``the EPA will impose

restrictions on production, thereby necessitating implementation of

replacement refrigerants quickly.'' Therefore, Fedders recommended

maintaining the current energy efficiency regulations until the issues

related to refrigerant charges are ``resolved and implemented into

commerce.'' (Fedders, RAC No. 7 and RAC No. 8.)

In its comments to the 1996 Draft Report, AHAM stated that the

issue of replacement refrigerants is a far more serious problem than

the Department acknowledges. It states that because of the size

restrictions of room air conditioners and because the compressor and

condenser are located in a window, the potential adverse effects of

high pressure refrigerants are higher, and low pressure alternates

demonstrate efficiency penalties. (AHAM, RAC No. 4 at 5.) In February

1997, AHAM requested that the Department make a provision for

compliance problems which may result from the transition to HCFC-free

refrigerants.

In their comments to the Draft Report, ACEEE and NRDC stated that

because the standard set forth in today's rule will cover the 2000-2005

time period, alternative refrigerants will likely be an issue for the

next statutorily required standard review but not this review. In

addition, the advocates state that it is unlikely for replacement

refrigerants to result in an energy penalty and may result in a slight

energy efficiency increase. (ACEEE/NRDC, RAC No. At 3.)

The Department agrees that the phase out date of 2010 for HCFC-22

is far enough in the future that no adjustment to these standards is

necessary. Replacements for HCFC-22 are being developed. Concerned over

the impact that the phase out of HCFC-22 would have on the unitary air

conditioner and heat pump industry, the Air Conditioning and

Refrigeration Institute initiated the Alternative Refrigerant

[[Page 50139]]

Evaluation Program (AREP). AREP has identified several HCFC-22

alternatives. Two of the more promising replacements include a low-

glide ternary blend consisting of HFC-32, HFC-125 and HFC-134a

refrigerants, and an azeotrope consisting of H.C.-32 and H.C.-125

refrigerants. A detailed discussion of replacement refrigerants can be

found on page 1.18 of the TSD.

Although two of the more promising alternatives demonstrate slight

disadvantages compared to R-22, the Department expects that the

performance characteristics of the available alternative refrigerant

blends will improve as more experience is gained with their use in

different formulations. The Department does not anticipate a problem

with degradation of performance of refrigerants related to the HCFC-22

phaseout. The EPA states that it does not intend to accelerate the

HCFC-22 phaseout. (RAC No. 19.) The Department recognizes the

possibility that the phaseout date could be accelerated or the

availability of HCFC-22 could diminish. DOE will continue to monitor

the situation and take appropriate actions.

Based on this information, the Department declines to establish a

two tier system that takes into account a possible degradation in

system performance using replacement refrigerants.

Exemption of refrigerant-gas free units. Fedders stated that in

order to promote the research and development of alternative air

conditioning systems, the Department should exempt refrigerant-gas free

room air conditioners from efficiency regulation. (Fedders, April 7,

1994, Transcript at 123.)

The Department will not exempt refrigerant-gas free room air

conditioners from efficiency regulation because the energy conservation

policies underlying the EPCA do not support such an exemption.

Installation Costs. A few commenters opposed the proposed standard

because of increased installation costs. (G&S No. 302 at 2; Amana, No.

347 at 2; Southwestern Public Service Co No. 495 at 5; Whirlpool, No.

391A at 4; CHGEC, No. 601 at 1; and AHAM No. 1 for some classes.)

The Department analyzed the net consumer benefit from the

imposition of the standards, estimating costs, including installation

costs, and benefits to the utility customer, and concluded that the

benefits outweighed the increased costs.

6. Other comments regarding FR Notice of January 29, 1997

Southern Company Services, Inc. stated that these standards appear

reasonable and economically justified. (Southern Gas, RAC No. 15 at 1.)

ACEEE and NRDC stated that the standards the Department indicated it

was inclined to select for the final rule were generally reasonable,

and they strongly supported those standards for the first five classes.

For the remaining classes, they suggested a few changes which were

addressed under ``Efficiency Standards Recommendations.'' (ACEEE/NRDC,

RAC No. 14 at 3.) AHAM stated that under two critical conditions, the

majority of their members accepted the standard levels the Department

indicated it was inclined to select in the January 29 notice. These

conditions concerned non-HCFC refrigerants and the effective date of

the standards, discussed in the previous section. (AHAM, RAC No. 16 at

1) Glenn Schleede of Energy Market & Policy Analysis, Inc. (EM&PA)

stated that the economic analysis is based on outdated and invalid

assumptions about potential energy costs. Mr. Schleede's comments dealt

specifically with: overestimating national energy cost savings; using

total residential electricity cost per kilowatt-hour to calculate

national and consumer energy savings; the utility impact model; and the

variables and assumptions used in the model. Mr. Schleede believes all

calculations of life cycle costs, payback periods, and consumer energy

cost savings in the TSD are based on unrealistically high estimates of

future energy (particularly electricity) prices. He also believes the

Department has not ``taken into account the interests of real

consumers.'' (EM&PA, RAC No. 17.)

In the analyses for the Draft Report, the Department utilized EIA

forecasts that have not yet addressed the possible price effects of the

electric utility regulatory reforms and industry restructuring that are

anticipated. Due to this and other uncertainties in electricity price

forecasts, the Department conducts sensitivity analyses to bound the

possible ranges of impacts. The Department intends to increase the use

of sensitivity analyses and scenario analyses in future rulemakings. 61

FR at 36987 (to be codified at 10 CFR Part 430, Subpart C, Appendix A,

section 11(e)(1)). The Department will continue to examine how to

better account for these changes in the future.

Various cases of Net Present Value (NPV) and life-cycle cost

sensitivity to changes in energy price and equipment price were

analyzed. These sensitivity analyses are discussed in section IV.c.2.,

``Life-cycle Cost and Net Present Value,'' of today's rule. These

sensitivity analyses included the effect of using the lowest state

energy prices on life-cycle cost and the use of energy price

projections provided by the Gas Research Institute to calculate NPV and

energy savings.

As a complement to energy price sensitivities, the Department

calculated the cost of conserved energy (CCE) for its appliance energy-

efficiency standards under consideration. The CCE is the increase in

purchase price amortized over the lifetime of the appliance. The

advantage of the CCE approach is that it does not require assumptions

about future energy prices, because it uses only the purchase expense

of the efficiency measure and the expected energy savings. The consumer

will benefit whenever the cost of conserved energy is less than the

energy price paid by the consumer for that end use. The CCE's

calculated for the standards set forth in today's rule are all less

than the energy prices projected by either the EIA or GRI. See

Supplemental tables 4.10-4.18 in the TSD.

For consumer impacts such as payback and changes in life cycle

cost, which are measured at the effective date of the standard, the

Department believes both fixed and variable costs should be included

because these costs are currently reflected in consumer utility bills

based on cost-of-service rates. It is not anticipated that the

reductions in energy demand resulting from energy efficiency standards

for room air conditioners are likely to have any significant effect on

consumer electricity rates (or prices).

In estimating the national net present value of the cost savings

resulting from more stringent efficiency standards, it may be

appropriate to distinguish between the expected cost impacts on

individual consumers and the cost impacts on the nation as a whole. To

determine whether there is a significant difference between consumer

and national cost impacts, it would be necessary to distinguish between

the long run fixed and variable costs of serving residential

electricity demand. For example, if electricity demand is reduced,

utilities will be able to cut back immediately on the fuel used to

generate electricity and, over the long run, should also be able to

reduce their power generating, transmission and possibly even their

distribution capacity. However, reduced demand is unlikely to affect

the cost to a utility of billing and servicing individual

[[Page 50140]]

customers. Furthermore, because virtually all consumer electricity

rates are still based on average costs and do not reflect the

variations in these costs that occur hourly, it is also possible that

improving the efficiency of particular appliances will result in

significant reductions in the high costs of meeting peak demand or, in

other cases, may simply reduce utility base loads (resulting in much

lower cost savings). Unfortunately, the Department does not have

adequate information upon which to distinguish accurately between

consumer cost savings and the cost reductions likely to be experienced

by utilities or the nation as a whole. In the absence of such

information, the Department believes that its use of retail prices as

the basis for calculating the net present value of projected cost

savings to the nation (national benefits) is a reasonable approach.

In addition to the impact of energy savings in today's world, there

is much speculation as to the impact of electric utility restructuring

on future electric rates. However, with federal and state regulations

being very undefined, the Department believes it would be pointless to

attempt to reflect unknown future electric rate structures in today's

analyses. In future rulemakings, the Department will consider such

impacts as they become evident. The Department concludes from the

information set forth above that it is properly calculating consumer

energy cost savings and national net present value.

With regard to the variables and assumptions used in the models,

the assumptions regarding discount rates have been discussed

extensively, and DOE used the discount rates it determined to be most

appropriate. For future rulemakings, the Department always seeks and

welcomes the most current information regarding its models and will

continue to improve them.

b. General Analytical Comments

This section discusses the general analytical issues raised by the

comments to the 1994 Proposed Rule.

The Engineering Analysis identified design options for improvements

in efficiency along with the associated costs to manufacturers for each

class of product. For each design option, these costs constitute the

increased per-unit cost to manufacturers to achieve the indicated

energy efficiency levels. Manufacturer, wholesaler, and retailer

markups will result in a consumer purchase price higher than the

manufacturer cost.

In the analysis which supported the Draft Report, the Department

used a computer model that simulates a hypothetical company to assess

the likely impacts of standards on manufacturers and to determine the

effects of standards on the industry at large. This model, the

Manufacturer Analysis Model (MAM), is described in the TSD. (See TSD,

Appendix C.) It provides a broad array of outputs, including shipments,

price, revenue, net income, and short- and long-run returns on equity.

An ``Output Table'' lists values for all these outputs for the base

case and for each of the five standard levels analyzed. It also gives a

range for each of these estimates. The base case represents the

forecasts of outputs with a range of energy efficiencies which are

expected if there are no new or amended standards. A ``Sensitivity

Chart'' (TSD, Appendix C) shows how returns on equity would be affected

by a change in any one of the nine control variables of the model. The

Manufacturer Analysis Model consists of 13 modules. The module which

estimates the impact of standards on total industry net present value

is version 1.2 of the Government Regulatory Impact Model (GRIM), dated

March 1, 1993, which was developed by the Arthur D. Little Consulting

Company (ADL) under contract to AHAM, the Gas Appliance Manufacturers

Association (GAMA), and the Air-Conditioning and Refrigeration

Institute (ARI). (See TSD, Appendix C for more details.)

Arthur D. Little, Inc. (ADL) submitted comments on the 1994

Proposed Rule on behalf of AHAM, the Air-Conditioning and Refrigeration

Institute (ARI), and the Gas Appliance Manufacturers Association

(GAMA.) ADL and others criticized the methodology and analytical models

used to assess standards. These comments raised concerns about the

determination of the impact of standards on manufacturers, particularly

the way the Department used the GRIM developed by industry, and the

failure to consider the impact of multiple DOE and other agency

regulations. Other analytical issues raised included the determination

of consumer paybacks from energy savings, expected life of the product,

economic assumptions, the use of prototypical firms, and other

assumptions and variables used in the simulation model. (ADL, No. 665

at 1, 8-10, 14-19; AHAM, Transcript April 7, 1994, at 173.) Amana

commented that historical models are difficult to construct and that

prices fluctuate, and therefore, the Department should not ``place too

much stock in computer models.'' Basing its statement on the consumer

price index (CPI), producer price index (PPI), and average energy use

trends, Amana also stated that there is no evidence to suggest that

capital cost increases due to efficiency improvements are passed on to

the consumer. (Amana, No. 347 at 2-3.)

In implementing the Process Rule, the Department is now undertaking

a review of the manufacturing impact analysis model and methodologies.

In developing its new methodology, the Department will take into

account the comments received concerning its methodology. However,

while DOE is committed to working with the interested public to improve

these analytical tools, DOE believes the analytical approach used in

conjunction with the Draft Report is a reasonable basis for assessing

manufacturer impact.

The Department recognizes that the manufacturers disagreed with the

analytical method used in the 1994 Proposed Rule and the Draft Report

regarding impacts on manufacturers. However, the Department assumes

that the standards recommended by AHAM would not have adverse impacts

on the industry or the individual manufacturers. The standards the

Department sets forth in today's rule are quite similar to those

recommended by AHAM. The Department has selected slightly higher (0.2-

0.3 EER) standards than those standards proposed by AHAM for the

classes 1 through 4. AHAM's primary concern was the impact of the cost

of chassis size increases on manufacturers. The Department took into

consideration a graph provided by AHAM which shows the percent of

production requiring a chassis size change at each EER level. In

selecting the standard levels for classes 1 through 4, the Department,

in an effort to mitigate the identified cost impact on manufacturers,

was careful to avoid any significant increase in the percentage of

production requiring a chassis size change.

ACEEE recommended that DOE compile the best available data on two

key variables: markup from manufacturer to the consumer and changes in

purchase patterns in response to efficiency-induced price increases.

This data should be used for the current analysis in both the

Government Regulatory Impact Model (GRIM) and the Manufacturer Impact

Model (MIM.) Over the long term, ACEEE suggested that DOE work with

industry to co-fund a study on consumer purchase behavior in response

to efficiency-induced price increases that would help improve the

[[Page 50141]]

usefulness of both GRIM and MIM. (ACEEE, No. 557 at 5.)

DOE has decided to integrate the GRIM with the MIM which has

resulted in the development of a new model entitled the Lawrence

Berkeley Laboratory Manufacturer Analysis Model (LBL-MAM.) The

Department will continue in its efforts to collect the best available

data on markups to use in its analytical tools. With regard to consumer

response to efficiency-induced price increases, the Department's

consumer analysis contains, for each covered product, values that

represent the likely response. These values were originally estimated

by analyses of data concerning product purchases during the 1970's and

have been updated. The Department continues attempting to update its

assumptions where updates are warranted and welcomes ACEEE's

suggestions. DOE will explore the feasibility of a cooperative study on

empirically-verifiable updates on price elasticity.

IV. Analysis of Room Air Conditioner Standards

Revised standards for room air conditioners shall be designed to

achieve the maximum improvement in energy efficiency that is

technologically feasible and economically justified. These and related

statutory criteria are addressed below.

a. Efficiency Levels Analyzed

The Department examined a range of standard levels for room air

conditioners. Table 4-1 presents the five efficiency levels selected

for analysis in the Draft Report, as well as the supplemental

efficiency level. Level 5 corresponds to the highest efficiency level,

max tech, considered in the engineering analysis. The Final TSD

contains the information analyzed in the Draft Report and the

supplemental analysis.

After analyzing the comments received concerning the Draft Report,

the Department decided to analyze an additional standard level, defined

as the supplemental level. The Department calculated the energy

savings, net present value, life-cycle cost, life-cycle cost

sensitivity to energy prices, payback period, and environmental

emissions reduction for this supplemental standard level. These tables

can be found in the Supplemental section of the TSD.

Table 4-1.--Standard Levels Analyzed for Room Air Conditioners

----------------------------------------------------------------------------------------------------------------

Suppl.

Product class Level 1 Level 2 level Level 3 Level 4 Level 5

----------------------------------------------------------------------------------------------------------------

Without reverse cycle, with

louvered sides, and less than

6,000 Btu/h...................... 9.32 9.71 9.7 10.00 10.38 11.74

Without reverse cycle, with

louvered sides, and 6,000 to

7,999 Btu/h...................... 9.38 9.66 9.7 9.91 10.33 11.67

Without reverse cycle, with

louvered sides, and 8,000 to

13,999 Btu/h..................... 9.71 9.85 9.8 10.11 10.97 12.39

Without louvered sides, with

reverse cycle, and 14,000 to

19,999 Btu/h..................... 9.70 9.98 9.7 10.15 10.15 12.77

Without reverse cycle, with

louvered sides, and 20,000 Btu/h

or more.......................... 8.39 8.39 8.5 8.51 8.88 11.14

Without reverse cycle, without

louvered sides, and less than

6,000 Btu/h...................... 9.10 9.10 9.0 9.23 9.23 11.52

Without reverse cycle, without

louvered sides, and 6,000 to

7,999 Btu/h...................... 9.10 9.10 9.0 9.23 9.23 11.52

Without reverse cycle, without

louvered sides, and 8,000 to

13,999 Btu/h..................... 8.80 9.05 8.5 9.12 9.12 11.08

Without reverse cycle, without

louvered sides, and 14,000 to

19,999 Btu/h..................... 8.80 9.05 8.5 9.12 9.12 11.08

Without reverse cycle, without

louvered sides, and 20,000 Btu/h

or more.......................... 8.80 9.05 8.5 9.12 9.12 11.08

With reverse cycle and with

louvered sides................... 9.05 9.05 9.0 9.27 9.27 11.16

With reverse cycle and without

louvered sides................... 8.72 8.72 8.5 8.86 8.86 10.87

----------------------------------------------------------------------------------------------------------------

Rather than presenting the results for all classes of room air

conditioners in today's rule, the Department selected a class of room

air conditioners as being representative, or typical, of the product

and is presenting the results only for that class. The results for the

other classes can be found in the TSD in the same sections as those

referenced for the representative class. The representative class for

room air conditioners is units with side louvers, without a reverse

cycle, and with a capacity of 8,000-13,999 Btu per hour. This class of

room air conditioners has the largest sales volume. For this

representative class, trial standard level 1 accomplishes efficiency

improvements from the baseline by increasing the compressor EER to

10.8; level 2 adds a subcooler; level 3 adds evaporator and condenser

grooved tubing; level 4 increases the evaporator and condenser coil

area; and level 5 adds a variable-speed compressor and brushless

permanent magnet fan motor. Similar design options are used to achieve

the above efficiencies for the other classes and are found tabulated in

Section 1.5 of the TSD. The supplemental level was not based on any

specific configuration of design options, but rather it resulted from

consideration of the comments DOE received regarding the Draft Report.

The analysis used in the Draft Report became the basis for the TSD.

Consequently, calculations in the TSD and today's rule are based on

those energy price forecasts from the 1995 Annual Energy Outlook (AEO)

of the Energy Information Administration (EIA) , the current forecast

at the time of the analysis, unless otherwise noted. (DOE/EIA-

0383(95)). Supplemental calculations were performed where the

Department determined it would be appropriate to reflect the most

current prices.

The Department believes that all the standard levels it examined

are technologically feasible. The only questions which were raised by

commenters about technological feasibility pertained to Brushless

Permanent Magnetic (BPM) fan motors and variable speed compressors.

These

[[Page 50142]]

design options were only considered at the most stringent standard

levels.

b. Significance of Savings

Under section 325(o)(3)(B) of EPCA, the Department is prohibited

from adopting a standard for a product if that standard would not

result in ``significant'' energy savings. The Department forecasted

energy consumption by the use of the LBL-REM. (See Appendix B of the

TSD.) To estimate the energy savings by the year 2030 due to revised

standards, the energy consumption of new room air conditioners under

the base case is compared to the energy consumption of those sold under

the candidate standard levels. For the candidate energy conservation

standards, the Lawrence Berkeley Laboratory-Residential Energy Model

projects that over the period 1999-2030, the following energy savings

would result for all classes of the product:

Level 1--0.36 Quad

Level 2--0.52 Quad

Supplemental Level--0.49 Quad

Level 3--0.69 Quad

Level 4--0.96 Quad

Level 5--0.72 Quad

The preceding values of energy savings use AEO 1995 energy price

forecasts; however, calculating the energy savings for the supplemental

level using AEO 1997 produces an energy savings of 0.64

Quad.5

---------------------------------------------------------------------------

\5\ AEO 1995 projected higher energy prices in the future as

compared to AEO 1997. Consequently, using AEO 1995 projections, a

larger percentage of consumers are projected to purchase higher

efficiency room air conditioners in the absence of standards (in the

base case), as compared to the base case using AEO 1997 projections.

This relative difference results in a larger projected energy

savings between the base case and the standards case using AEO 1997

projections as compared to AEO 1995 projections.

---------------------------------------------------------------------------

While the term ``significant'' is not defined in EPCA, the U.S.

Court of Appeals for the District of Columbia Circuit concluded that

Congress intended the word ``significant'' to mean ``non-trivial.''

Natural Resources Defense Council v. Herrington. 768 F.2d 1355, 1373

(D.C.Cir. 1985). Thus, for this rulemaking, DOE concludes that each

standard level considered results in significant energy savings.

c. Economic Justification

Section 325(o)(2)(B) of EPCA provides seven factors to be

evaluated, to the greatest extent practicable, in determining whether a

conservation standard is economically justified.

1. Economic Impact on Manufacturers and Consumers

The engineering analysis identified improvements in efficiency

along with the associated costs to manufacturers for each efficiency

level for each class of product. For each design option, these

associated costs constitute the increased per-unit cost to

manufacturers to achieve the indicated energy efficiency levels.

Manufacturer, wholesaler, and retailer markups will result in a

consumer purchase price higher than the manufacturer cost.

To assess the likely impacts of standards on manufacturers and to

determine the effects of standards on different-sized firms, the

Department used a computer model that simulates hypothetical firms in

the industry under consideration. This model, the Manufacturer Analysis

Model (MAM), is explained in the TSD. (See TSD, Appendix C.)

For consumers, measures of economic impact are the changes in

purchase price, annual energy expense, and installation costs. The

purchase price, installation cost, and cumulative annual energy

expense, i.e., life-cycle cost, of each standard level are presented in

Chapter 3 of the TSD. Under section 325 of the EPCA, the life-cycle

cost analysis is a separate factor to be considered in determining

economic justification.

The per unit increased costs to manufacturers to meet the

efficiency of levels 1-5 for the representative class are $6.11, $8.37,

$13.17, $47.09, and $242.52, respectively. The increased per unit cost

for the supplemental level falls within the range of $6-$9 for the

representative class. See Tables 1.10-1.18 in the TSD.

The consumer price increases for the representative class are

estimated to be $11, $15, $23, $82, and $434 for standard levels 1-5,

respectively. The consumer price increase for the supplemental level is

estimated to be $13. See Tables 4.1-4.9 and Supplemental Tables 4.1-4.9

in the TSD.

The per-unit reduction in annual costs of operation (i.e., energy

expense) for the representative class are $2, $3, $4, $8, and $13 for

standard levels 1-5, respectively, and $2.5 for the supplemental level.

See Tables 4.1-4.9 and Supplemental Tables 4.1-4.9 in the TSD.

The Lawrence Berkeley Laboratory-Manufacturer Impact Model results

for all classes of room air conditioners show that revised standards

could cause a prototypical manufacturer to have some reductions in

short-run return on equity from the 10.9 percent return in the base

case. Standard levels 1 through 5 are projected to produce short-run

returns on equity of 10.7 percent, 10.6 percent, 10.5 percent, 8.8

percent, and 0.13 percent, respectively. The short-run return on equity

for the supplemental level is projected to be in the range of 10.5-10.7

percent. Revised standards have little or no effect on the prototypical

manufacturer's long-run return on equity. Standard levels 1 through 5

are projected to produce long-run returns on equity of 10.8 percent,

10.8 percent, 10.8 percent, 10.3 percent, and 7.2 percent,

respectively. For the supplemental level the long-run return on equity

would also be approximately 10.8 percent. See Tables 5.1 and 5.3 in the

TSD.

2. Life-cycle Cost and Net Present Value

One measure of the effect of proposed standards on consumers is the

change in life-cycle costs, including recurring operating expenses, the

purchase price, and the installation costs resulting from the new

standards. The change in life-cycle cost is quantified by the

difference in the life-cycle costs between the base case and candidate

standard case for each of the product classes analyzed. The life-cycle

cost is the sum of the purchase price and the cumulative operating

expense, including installation and maintenance expenditures,

discounted over the lifetime of the appliance. The life-cycle cost was

calculated for the range of efficiencies analyzed in the ``Engineering

Analysis'' section of the TSD, for each class, in the year standards

are imposed, using real consumer discount rates of six percent.

For the representative class, life-cycle costs at standard levels

1-3 as well as the supplemental level are less than the baseline unit.

Standard level 1 would reduce life-cycle costs for the average affected

consumer of $6.76 for the representative class of room air conditioner;

standard level 2 would reduce average life-cycle costs by $6.67,

standard level 3 by $8.48, and the supplemental level by $6.59; for

standard levels 4 and 5, the life-cycle costs are projected to increase

$19.4 and $328, respectively, compared to the base case. Of the five

candidate standard levels, a unit meeting standard level 3 would have

the lowest consumer life-cycle cost for the representative class. See

Figures 4.4, Tables 4.1-4.18, and Supplemental Tables 4.1-4.18 in the

TSD.

The Department's baseline method of analysis 6

calculated costs of increasing

[[Page 50143]]

chassis size at the standard level at which the baseline required a

chassis size change. This analysis produced the preceding values for

life-cycle cost. In addition, AHAM provided analysis in which the cost

of increasing chassis size was prorated at each standard level. Using

this method and the data provided by AHAM (AHAM, RAC No. 9 at

Attachment 3A), for classes 1-5, which make up 85 percent of the

shipments, the supplemental standard level has the lowest life-cycle

cost when prorating chassis size cost.

---------------------------------------------------------------------------

\6\ The engineering analysis is conducted on the basis of

selecting a representative ``baseline'' unit for each room air

conditioner product class. The selected ``baseline'' unit is an

actual room air conditioner model that has an EER close to the

existing minimum efficiency standard and a cooling capacity that is

representative of most units in the product class. The physical

characteristics of the ``baseline'' unit (e.g., compressor

efficiency and heat exchanger design) dictate which design options

can be considered to improve its efficiency and at what rate the

manufacturer cost will be increased. The selected ``baseline''

unit's physical make-up is known not to be representative of all

minimum efficiency equipment in its product classes. But because its

EER and capacity are representative, it is assumed that the design

options that are added to improve its efficiency will yield a

manufacturer cost vs. efficiency relationship that is representative

of all ``baseline'' units in the product class, irrespective of

physical design.

---------------------------------------------------------------------------

The Department examined the effect of different discount rates (2,

6, and 15 percent) on the life-cycle cost curves and generally found

little impact. See Figures 4.1-4.9 in the TSD. Life-cycle cost

sensitivity to changes in energy price and equipment price were

analyzed. See Figure 4.10, Table 4.19, and Supplemental Table 4.19 in

the TSD. This analysis shows that the life-cycle cost minimums remain

unchanged at high energy prices. For low State energy prices, any

increase in standard above the baseline, shows a life-cycle cost

increase; however, through standard level 3, this increase is less than

$3 (and approximately $1 for the standards in today's rule).

As previously addressed under Discussion of Comments, the

Department also calculated life cycle costs and paybacks using energy

prices calculated by the Gas Research Institute (GRI). (See the

Supplemental Sensitivity Analysis subsection of the TSD.) The life-

cycle minimums resulting from the GRI projections remain unchanged from

the analysis using the AEO price forecasts. The payback periods

increase slightly, using the GRI forecasts, but remain well within the

expected lifetime of the product.

The Net Present Value analysis, a measure of the net savings to

society, indicates that for all classes of room air conditioners,

standard level 1 would produce an NPV of $0.40 billion to consumers.

The corresponding net present values for standard levels 2-5 are $0.54

billion, $0.59 billion, $-0.26 billion, and $-10.9 billion,

respectively (based on AEO 1995 energy price projections). See Table

3.6 in the TSD. The NPV for the supplemental level is $0.51 billion

using AEO 1995, for basis of comparison. Using AEO 1997 data, the NPV

of the supplemental level is calculated to be $0.45 billion. See the

Supplemental Sensitivity Analysis subsection of the TSD.

A sensitivity analysis was also conducted for energy savings and

Net Present Value (NPV), using GRI forecasts for the following cases:

the GRI fuel price projection, low equipment price, high equipment

price, and high efficiency trend. (See the Supplemental Sensitivity

Analysis subsection of the TSD.) The results of this analysis show that

although the NPV and energy savings change in each scenario, both the

NPV and the energy savings remain positive, indicating an overall

benefit to the consumer and the nation.

3. Energy Savings

EPCA requires DOE to consider the total projected energy savings

that result from revised standards. The Department forecasted energy

consumption through the use of the LBL-REM. (See Appendix B of the TSD

for a detailed discussion of the LBL-REM.) The projected savings using

AEO 1997 is 0.64 Quad for the supplemental level. See Supplemental

Table 3.97 in the TSD. Also, see section IV.c. in today's rule for the

energy savings of the other efficiency levels.

4. Lessening of Utility or Performance of Products

In establishing classes of products and design options, the

Department tried to eliminate consideration of any design option that

would result in degradation of utility or performance. Thus, a separate

class with a different efficiency standard was created for a product

where the record indicated that the product included a utility or

performance-related feature that affected energy efficiency. For

example, the Department added classes for casement-only and casement-

slider room air conditioners. These room air conditioners offer the

unique utility of fitting into slider and casement windows. In this

way, the Department attempted to minimize the impact of amended

standards on the utility and performance of room air conditioners.

5. Impact of Lessening of Competition