Large Multiple-Tube Fireworks Devices; Final Rule

Federal RegisterMar 26, 1996

Ask Donna

What actually matters in this document.

Text

CONSUMER PRODUCT SAFETY COMMISSION

16 CFR Part 1500 and Part 1507

Large Multiple-Tube Fireworks Devices; Final Rule

AGENCY: Consumer Product Safety Commission.

ACTION: Final rule.

-----------------------------------------------------------------------

SUMMARY: The Commission is amending its fireworks regulations under the

Federal Hazardous Substances Act. This final rule will require that

large multiple-tube fireworks devices that have any tube with an inner

diameter of 1.5 inches (3.8 cm) or greater pass a performance test for

stability. Under the test, these devices may not tip over when inclined

at an angle of 60 degrees from the horizontal. This requirement is

intended to reduce the risk of injury posed when these fireworks

devices tip over during firing. If they tip over, subsequent tubes may

discharge in the direction of spectators or others in the vicinity.

DATES: The rule will take effect on March 26, 1997, and will apply to

multiple-tube fireworks devices in which any tube has an inner diameter

of 1.5 inches or greater and that first enter interstate commerce or

are imported on or after that date.

Adversely affected persons have until April 25, 1996 to file

objections to this rule, stating grounds therefor and requesting a

public hearing on those objections. Objections and requests for

hearings must be mailed to the Office of the Secretary, Consumer

Product Safety Commission, Washington, D.C. 20207, or delivered to the

Office of the Secretary, Room 502, 4330 East-West Highway, Bethesda,

Maryland 20814 telephone (301) 504-6800.

FOR FURTHER INFORMATION CONTACT: Samuel B. Hall, Office of Compliance,

Consumer Product Safety Commission, Washington, DC 20207-0001;

telephone (301) 504-0400, ext. 1371.

SUPPLEMENTARY INFORMATION:

A. Background

Multiple-tube mine and shell fireworks devices (also called

``display racks'' and referred to in this notice as ``multiple-tube

devices'') are non-reloadable devices that fire multiple aerial shells,

comets, or other effects into the air to produce visual and audible

effects. These devices consist of several vertical tubes with a common

fuse, either with or without a horizontal base. They are classified by

the Department of Transportation (``DOT'') as 1.4G explosive devices

(formerly Class C common fireworks devices) which are suitable for use

by consumers.

The devices are designed to fire sequentially. This creates the

danger that the device's reaction to one shot may cause it to tip over.

Subsequent shots may then fire horizontally or at an angle and hit the

operator or spectators. The Commission is aware of two deaths to

spectators involving multiple-tube devices that occurred in this

manner. Both of these incidents involved devices with tubes larger than

1.5 inches in diameter.

The Commission regulates fireworks devices under the Federal

Hazardous Substances Act (``FHSA''). 15 U.S.C. 1261-1278. Under its

current regulations, the Commission has declared certain fireworks

devices to be ``banned hazardous substances.'' 16 CFR 1500.17(a) (3),

(8) and (9). Other fireworks devices must meet specific requirements to

avoid being classified as banned hazardous substances. 16 CFR Part

1507. Commission regulations also prescribe specific warnings required

on various legal fireworks devices, 16 CFR 1500.14(b)(7), and designate

the size and location of these warnings. 16 CFR 1500.121.

On July 1, 1994, the Commission issued an advance notice of

proposed rulemaking (``ANPR'') discussing the

[[Page 13085]]

hazard presented by multiple-tube devices of all sizes, but noted that

more severe incidents have occurred with large devices. 59 FR 33928.

The ANPR used 1 inch (2.54 cm) as the cutoff between small and large

devices. The ANPR explained that the Commission was considering the

following regulatory alternatives: (1) ban all multiple-tube devices;

(2) ban multiple-tube devices with an inside tube diameter of greater

than 1 inch; (3) require additional labeling on all multiple-tube

devices; (4) establish performance or design criteria to modify these

devices; (5) pursue individual product recalls; and (6) take no

mandatory action, but encourage development of a voluntary standard.

On July 5, 1995, the Commission issued a notice of proposed

rulemaking (``NPR'') in which it proposed a performance standard for

multiple-tube devices with any tube inner diameter of 1.5 inches or

more. 60 FR 34922. The Commission found that 1.5 inches is a more

appropriate measure to distinguish between large and small devices than

is 1 inch, and decided not to propose any further regulatory

requirements for smaller devices.1 The proposed performance

standard provided that all large multiple-tube devices have a minimum

tip angle greater than 60 degrees. With this notice, the Commission

issues the performance standard as a final rule.

\1\ The Commission concluded that additional work would be

needed to develop a standard that adequately addressed the tip-over

hazard with small (less than 1.5 inch diameter) multiple-tube

devices. For example, the Commission would need to test small

devices to determine if the 60-degree tip angle is the proper

criterion for this size device. Further, smaller devices are likely

to produce less force on impact, and may be less likely to cause

fatal injuries. Because not many small devices are marketed and the

known incidents involve large devices, a performance standard for

small multiple-tube devices may not be necessary. Accordingly, the

Commission decided to apply the stability criterion only to large

devices.

---------------------------------------------------------------------------

B. Statutory Authority

This proceeding is conducted under the FHSA. 15 U.S.C. 1261-1278.

Fireworks are ``hazardous substances'' within the meaning of section

2(f)(1)(A) of the FHSA because they are flammable or combustible

substances, or generate pressure through decomposition, heat, or other

means, and ``may cause substantial personal injury or substantial

illness during or as a proximate result of any customary or reasonably

foreseeable handling or use * * *.'' 15 U.S.C. 1261(f)(1)(A).

Under section 2(q)(1)(B) of the FHSA, the Commission may classify

as a ``banned hazardous substance'' any hazardous substance intended

for household use which, notwithstanding the precautionary labeling

that is or may be required by the FHSA, presents such a hazard that

keeping the substance out of interstate commerce is the only adequate

way to protect the public health and safety. Id. at 1261(q)(1)(B). A

proceeding to classify a substance as a banned hazardous substance

under section 2(q)(1) of the FHSA is governed by sections 3(f)-(i) of

the FHSA, and by sections 701(e)-(g) of the Federal Food, Drug, and

Cosmetic Act (``FDCA''), 21 U.S.C. 371(e)-(g). See 15 U.S.C.

1261(q)(2).

The July 1, 1994, ANPR was the required first step to declare the

specified multiple-tube devices to be banned hazardous substances under

section 2(q)(1). See 15 U.S.C. 1262(f). The proposed rule, published on

July 5, 1995, continued the regulatory process in accordance with 15

U.S.C. 1262(h). To fulfill additional statutory requirements, this

notice includes the text of the final rule and a final regulatory

analysis. Id. at 1262(i)(1). As required by the FHSA, the Commission

also makes findings here that: (1) compliance with any relevant

voluntary standard is unlikely to adequately reduce the risk of injury,

or substantial compliance by the industry with the voluntary standard

is unlikely; (2) the expected benefits of the regulation bear a

reasonable relationship to its expected costs; and (3) the regulation

imposes the least burdensome requirement that would adequately reduce

the risk of injury. Id. at 1262(i)(2).

C. Filing Objections Under Section 701(e) of the FDCA

The procedures established under section 701(e) of the FDCA also

govern this rulemaking. 15 U.S.C. 1261(q)(2). These procedures provide

that once the Commission issues a final rule, persons who would be

adversely affected by the rule have 30 days in which to file objections

with the Commission stating the grounds therefor, and to request a

public hearing on those objections. 21 U.S.C. 371(e). If objections are

filed, a hearing to receive evidence concerning the objections would be

held. The presiding officer would then issue an order, based upon

substantial evidence. Id. The Commission's procedural rules at 16 CFR

Part 1502 would apply to such a hearing.

Any objections and requests for a hearing must be filed with the

Commission's Office of the Secretary. They will be accepted for filing

if they meet the following conditions: (1) they are submitted within

the 30-day period specified; (2) each objection is separately numbered;

(3) each objection specifies with particularity the provision(s) of the

regulation to which the objection is directed; (4) each objection on

which a hearing is requested specifically requests a hearing; and (5)

each objection for which a hearing is requested includes a detailed

description of the basis for the objection and the factual information

or analysis in support thereof (failure to include this information

constitutes a waiver of the right to a hearing on that objection). 16

CFR 1502.6.

The Commission will publish a notice in the Federal Register

specifying any parts of the regulation that have been stayed by the

filing of proper objections or, if no objections have been filed,

stating that fact. Id. at Sec. 1502.7. As soon as practicable, the

Commission will review any objections and hearing requests that have

been filed to determine whether the regulation should be modified or

revoked, and whether a hearing is justified. Id. at Sec. 1502.8.

D. The Product

As explained in the proposed rule, this rulemaking only applies to

multiple-tube devices that have any tube equal to or greater than 1.5

inches in inner diameter (referred to below as ``large devices'').

Large devices were first introduced by domestic manufacturers around

1986. Generally, they consist of three or more tubes grouped together,

sometimes on a wooden base, and fused in a series to fire sequentially.

Bases, where used, come in a variety of sizes. The devices fire aerial

shells, comets, or other effects from the tubes, producing visual and

audible effects. These devices are among the largest fireworks

available to consumers. [13] 2

\2\ Numbers in brackets refer to documents listed at the end of

this notice.

---------------------------------------------------------------------------

The tubes may be individually labeled or have a single label

surrounding them. Commission regulations require that all multiple-tube

devices display the following conspicuous label:

Warning (or Caution) Emits Showers of Sparks (or Shoots Flaming Balls,

if More Descriptive)

Use only under [close] adult supervision.3

\3\ The word ``close'' is optional.

---------------------------------------------------------------------------

For outdoor use only.

Place on a hard smooth surface (or place upright on level ground, if

more descriptive).

Do not hold in hand.

Light fuse and get away.

16 CFR 1500.14(b)(7)(ix).

The National Fireworks Association (``NFA'') reports that retail

sales of large multiple-tube devices are between $24

[[Page 13086]]

and $36 million annually, with an estimated 400,000 to 700,000 units

sold per year. Prices range from $30 to $130 per unit, with most

devices in the $50 to $60 range. The NFA also reports that domestic

devices account for about 75 percent of the market by dollar volume and

somewhat less by unit sales. Imported devices are manufactured

primarily in China, and go through several wholesalers before reaching

the retail vendor. [13] Some devices have tubes that are imported from

China and then are inserted into larger tubes and assembled with bases

in the United States. CPSC considers such devices to be imported.

E. Risk of Injury

The devices fire sequentially, and under some conditions the force

from one shot can tip the device over, causing it to fall into a

horizontal position. A subsequent shot can discharge as the device is

falling or when it is horizontal. When this occurs, there is a risk

that one of the projectiles may strike the operator of the device or

spectators and cause serious injury, or even death.

The Commission is aware of two deaths involving large multiple-tube

devices. In both incidents, the device tipped over while functioning. A

projectile then fired horizontally from the device and struck the

victim. In each case, the victim was a spectator.

The first fatality occurred in July of 1991. A 3-year-old boy was

standing between his father's legs approximately 40 feet from an area

where fireworks were being set off at a family reunion. The device had

been placed on concrete blocks. The device tipped over after the third

shot, and the fourth shell fired horizontally in the direction of the

boy, striking him in the left ear. He died the next morning. [2, Tab A]

The second fatality occurred in July of 1992. The victim, a 65-

year-old grandmother, was sitting at the end of a picnic table watching

a family fireworks display approximately 40 feet away. Her son placed a

large multiple-tube device on a piece of wafer board that extended

about one foot over the end of a boat dock. He placed a 2x4 block of

wood under the end of the board so that the device would shoot out over

the lake. After lighting the device, he walked toward the shore and

noticed that the device had tipped over after the third shot. The

fourth shell discharged horizontally and struck his mother in the

temple and eye. She died the next morning. [2, Tab A]

CPSC's compliance testing indicates that the tip-over risk

evidenced by these two incidents continues to exist. In fiscal year

1994, all 24 samples of imported devices tested for the Commission's

routine compliance program, and 1 of 8 samples of domestic devices,

tipped over while functioning. In fiscal year 1995, 22 of 27 imported

samples and 1 of 5 domestic samples tipped over. [19]

F. Commission Tests to Develop a Standard

1. Testing Prior to the ANPR

After the first fatality, several domestic manufacturers of large

multiple-tube devices began developing a test for the potential of

these devices to tip over while functioning. The test used a 2-inch (5

cm) thick block of medium-density (2 pounds per cubic foot or 0.032g/

cm\3\) polyurethane upholstery foam to simulate uneven surfaces. When

placed on this surface, if a device tipped over while functioning, it

was deemed too unstable.

The American Fireworks Standards Laboratory (``AFSL'') then began

work to revise its standard for these devices to incorporate such a

dynamic stability test. AFSL issued an interim revised voluntary

standard in January 1993 and adopted it without changes on September 5,

1995. The Commission also collected samples of large multiple-tube

devices and tested them for tip-over using the industry's dynamic

stability test. [1 and 14]

2. CPSC's Dynamic Stability Testing

After issuing the ANPR, the Commission staff attempted to develop a

dynamic stability test that could provide a reliable performance

standard for multiple-tube devices. The staff's objective was to

develop a test that could reliably distinguish between large multiple-

tube devices that are dangerously unstable and those that do not

present an unreasonable tip-over risk. The staff attempted to identify

a test surface that would simulate grass (the surface believed to be

commonly used for fireworks displays), and that would produce

consistent results in repeated tests.

To accomplish this goal, the Commission had to identify a surface

on which the devices would consistently tip over or remain upright in a

manner corresponding to how the devices perform on grass. If the tip-

over rate was substantially greater on the test surface than on grass,

the standard might be too stringent, causing unnecessary changes to

reasonably safe products. If the tip-over rate was substantially lower

on the test surface than on grass, the standard might not adequately

protect consumers.

As explained in detail in the Federal Register notice that

published the proposed rule, the staff's testing did not yield

sufficiently reliable results to propose a dynamic standard. 60 FR

34922, 34924. The staff tested devices on several types of foam. First

it tested with 2-inch thick foams of three different densities. This

thickness was chosen, in part, because the AFSL standard specifies 2-

inch thick medium-density foam. However, the tip-over rates with all

three densities of two-inch thick foam in this initial test were

significantly greater than with grass (39 to 50 tip-overs out of 50

devices on foam compared with 4 out of 50 on grass). The staff then

tested three high-density foams of smaller thicknesses (0.75, 1.0, and

1.5 inches), hoping to better match the tip-over rates on grass. [6, 8]

However, none of the these three foams agreed consistently with grass

for all three devices tested. The results of this phase of testing are

summarized in Table 1.

Table 1.--Phase I--Incidence and Percentage of Tip-Over With Large

Multiple-Tube Devices on Grass or High Density Polyurethane Upholstery

Foam

------------------------------------------------------------------------

Polyurethane foam

-----------------------------

Device Grass 0.75

inch 1.0 inch 1.5 inch

------------------------------------------------------------------------

1............................... 4/50 4/50 14/50* 40/50*

8% 8% 28% 80%

2a.............................. 32/50 9/50* 25/50 43/50*

64% 18% 50% 86%

3a.............................. 27/50 2/50* 3/50* 7/50*

[[Page 13087]]

54% 4% 6% 14%

------------------------------------------------------------------------

* Significantly different from grass, Pa Device modified to increase tip-over rate.

Of the three foams, 1-inch foam appeared to offer the best overall

relationship to grass, even though it produced inconsistent results.

[6, 8] Therefore, the staff continued testing with this foam.

In phase II of the Commission's testing, six additional devices

were tested on grass and on 1.0-inch thick high density foam. The

results were then combined with the results from phase I. Once again,

however, there was not consistent agreement between the tip-over rates

on foam and on grass (see Table 2).

Table 2.--Phase II--Incidence and Percentage of Tip-Over With Large

Multiple-Tube Devices on Grass or 1.0-Inch High Density Polyurethane

Upholstery Foam

------------------------------------------------------------------------

Device Grass Foam

------------------------------------------------------------------------

1 a................................................. 4/50 14/50 *

8% 28%

2 b................................................. 32/50 25/50

64% 50%

3 b................................................. 27/50 3/50 *

54% 6%

4 b................................................. 30/50 36/50

60% 72%

5................................................... 0/90 0/50

0% 0%

6 a................................................. 10/50 25/50 *

20% 50%

7................................................... 0/50 0/50

0% 0%

8................................................... 0/90 0/50

0% 0%

9................................................... 0/50 0/50

0% 0%

------------------------------------------------------------------------

* Significantly different from grass, Pa Device has no base.

b Device modified to increase tip-over rate.

The staff concluded that the dynamic stability test it attempted to

develop could not reasonably form the basis for a standard addressing

the tip-over hazard with large multiple-tube devices. Particularly

problematic was the dynamic test's inconsistency. There were two cases

(devices 1 and 6) in which foam significantly overpredicted the tip-

over rate with grass. In another case (device 3) foam significantly

underpredicted the tip-over rate with grass. [6, 8] These tests showed

a highly significant ``interaction'' between the device and test

surface, so that one could not accurately predict, based on a device's

performance on foam, how the device would behave on grass. An accurate

test is needed to avoid unwarranted market disruption and, more

importantly, because a tip-over can lead to a fatality.

3. The Tip-Angle Test

Since the Commission's testing on foam did not yield a reliable

dynamic test, the staff looked to the physical properties of large

multiple-tube devices to develop a static test. The staff measured the

dimensions, mass, and static tip-over resistance (``tip angle'') of all

the devices tested. The angle at which a device will first tip over

depends on its base-height ratio, mass, and center of gravity. A

device's dynamic stability--its ability to remain upright when fired--

depends on its tip angle and other factors, such as its lift force, the

firing order, and the time between firings. The staff found that tip

angle could predict whether a device would tip over while functioning

and also be sufficiently sensitive for routine compliance testing. [9]

The staff measured the tip angle of devices by placing one edge of

the device against a mechanical stop approximately \1/16\-inch high (to

prevent sliding) at the edge of a horizontal hinged platform. The

platform was slowly raised from the horizontal until the device tipped

over. The tip angle was considered to be the angle at which the device

first tips over. The staff repeated the test for each edge of the

device to determine its minimum tip angle. In this manner, the staff

measured the tip angle for the nine large devices used in the dynamic

tests. The staff then compared these measurements and the results of

the dynamic tests to determine whether there was a relationship between

the minimum tip angle of a device and its dynamic stability on grass

(see Table 3). [9]

Table 3.--Static Tip-Over Resistance and Dynamic Tip-Over Rate of Large

Multiple-Tube Devices

------------------------------------------------------------------------

Tip-over rate on

grass

Minimum tip angle (degrees) ---------------------- Device

Percent Incidence

------------------------------------------------------------------------

35, 42 b................................ 54 27/50 3 a

37...................................... 64 32/50 2 a

37...................................... 20 10/50 6

37...................................... 8 4/50 1

40...................................... 60 30/50 4 a

61...................................... 0 0/90 5

64...................................... 0 0/50 7

65...................................... 2.5 1/40 4

68...................................... 0 0/40 2

69...................................... 0 0/50 9

70...................................... 0 0/40 3

78, 80 b................................ 0 0/90 8

------------------------------------------------------------------------

a Device modified to increase tip-over rate.

b Different samples of same device.

The staff also tested several large devices other than those it had

examined when considering a dynamic test. One device was a modified

form of device 1, that originally had no base. The staff glued a 12-

inch (30.5-cm) square particleboard base to the device. With this

modification, the tip angle increased from 37 degrees to 68 degrees.

The tip-over incidence on grass also decreased, from 4/50 to 0/50. This

additional test demonstrates that a device's stability can be improved

by adding a base. [9]

The second additional device that the staff tested, an imported

one, had a square plastic base. The tip angle of this device ranged

from 54 to 55 degrees (based on measurements of four individual

samples), and it did not tip over in 50 dynamic tests on grass. [16]

4

\4\ The staff had previously tested this type of device (tip

angle: 52-55 degrees and tip-over rate: 2/40), but the bases of some

of the devices in the earlier test were cracked. Therefore, the

Commission does not consider the earlier tests to be reliable and

has not considered them in determining an appropriate tip angle. [10

and 11]

---------------------------------------------------------------------------

None of the seven devices originally tested had tip angles between

43 and 61 degrees. Therefore, the staff modified the base of a device

that had a large particleboard base in order to obtain a tip angle near

50 degrees. The staff

[[Page 13088]]

trimmed 2\1/16\ inches off each of the two long edges of the base. The

minimum tip angle of the device then ranged from 50 to 51 degrees

(based on measurements of eight individual samples). This modified

device tipped over in 33 out of 51 tests on grass. [16] Table 4 shows

the tip angles and tip-over rates of the three additional devices that

the staff tested.

Table 4.--Static Tip-Over Resistance and Dynamic Tip-Over Rate of Additional Large Multiple-Tube Devices a

----------------------------------------------------------------------------------------------------------------

Tip-over rate on grass

Minimum tip angle (degrees) -------------------------- Description of device

Percent Incidence

----------------------------------------------------------------------------------------------------------------

50-51 b............................. 65 33/51 Four-tube device with base. Base trimmed to

obtain 50 degree tip angle.

54-55 b............................. 0 0/50 Seven-tube device with plastic base.

68.................................. 0 0/50 Seven-tube device. Same as device 1, but with

added 12 inch base.

----------------------------------------------------------------------------------------------------------------

a Does not include devices that the staff considered to present inconclusive results.

bRange of values for replicate samples.

The Commission proposed and now issues in final a standard

requiring that large multiple-tube devices must have a minimum tip

angle above 60 degrees. The Commission's data indicate that

substantially all of the devices measuring a tip angle above 60 degrees

did not tip over while functioning on grass. Among such devices, there

was only one tip-over in 450 tests. On the other hand, devices with tip

angles below 60 degrees had tip-over rates on grass as high as 65

percent. Among all devices tested with tip angles below 60 degrees,

there were 136 tipovers in 351 tests.

The Commission believes that requiring devices to have minimum tip

angles above 60 degrees offers an appropriate margin of safety. The

fact that the staff observed no tip-overs with one device that had a

tip angle of 54-55 degrees might appear to suggest that a tip angle of

54 degrees would be sufficient to protect against the tip-over hazard.

However, a device that had a tip angle of 50-51 degrees had a very high

incidence of tip-overs (33/51). This device had a small base, and would

have been even less stable if, like a number of other devices on the

market, it had no base extending outward from the tube configuration.

Thus, it is likely that some devices with 55-degree tip angles would

tip over when tested on grass. Furthermore, the tests were performed on

level ground, and in actual use there probably will be significant

variations from level in a number of cases. The Commission concludes

that in order to adequately protect the public, it is appropriate to

require that the minimum tip angle be above 60 degrees.

AFSL submitted comments on the NPR that included results from its

testing of 43 units (13 different devices). AFSL reported that 35

percent of the units it tested met a 60-degree tip-angle test and that

none of the devices it tested tipped in actual firing. As explained

below in Section G of this notice, this limited testing does not show

that a requirement for a tip angle above 60 degrees is too stringent a

measure of whether a multiple-tube device is unlikely to tip over in

use.

G. Comments Responding to the Proposed Rule

The Commission received eight comments in response to the proposed

rule. Some commenters stated that they support the proposed rule.

Significant issues raised by other comments, and the Commission's

responses, are summarized below.

1. Scope of the Rule

AFSL stated that it agreed with the Commission's decision to limit

the scope of the proposed rule to large multiple-tube devices and that

the Commission was correct in concluding that devices with inside

diameters greater than 1 inch, but less than 1.5 inches, are not

common.

2. Need for a Rule

Some commenters stated that the need for a rule had not been

demonstrated because the number of reported injuries is low or because

the injuries are caused by consumer misuse. As explained below, the

Commission disagrees with these contentions.

a. Injury Data

Comments: One commenter claimed that the number of multiple-tube

devices has increased, but that the number of injuries associated with

them has not. The commenter concludes that the small number of injuries

and deaths associated with multiple-tube devices or Class C fireworks

does not justify further regulation. This commenter also claimed that

multiple-tube fireworks devices are no different from other fireworks

with respect to the potential for injury.

One group of commenters stated that in their evaluation of injuries

recorded in the state of Indiana, multiple-tube devices and other

consumer fireworks either have not tipped over or have caused few or no

injuries.

Response: Mine and shell devices (both single and multiple shot)

are more powerful than most consumer fireworks. Although the number of

deaths and injuries associated with mine and shell devices is

relatively low, the severity of injuries is greater than with other

devices. Any tip-over of large multiple-tube devices has the potential

to cause death or serious injury. Two individuals are known to have

been struck by large multiple-tube devices. Both suffered fatal

injuries.

The yearly unit sales figures for fireworks are unknown. Therefore,

the Commission cannot accurately assess any possible trends in exposure

to large multiple-tube devices. However, the cases show that the

potential for tip-over and serious injury or death is high under

certain conditions of foreseeable use. Since, as explained below, there

is no voluntary standard that can adequately reduce this risk, the

mandatory standard proposed by the Commission is necessary.

Comment: The commenters on the Indiana data also requested that the

Commission survey dealers to inquire about reported cases or instances

of a problem with a multiple-tube mine and shell device.

Response: As noted above, a mandatory standard is appropriate

despite the low number of reported deaths and injuries. In view of

this, there is no need to perform the requested survey.

Comment: AFSL contends that the lack of any known serious injury

attributed to large multiple-tube devices since the adoption of the

AFSL standard in 1993 supports their view that the voluntary standard

is adequate.

[[Page 13089]]

Response: These devices had been on the market for 6 years by the

time the two known deaths occurred. Thus, the absence of any known

deaths since 1993 is not statistically significant. The adequacy of

AFSL's standard, and the extent to which it is adopted by industry, are

discussed below under the responses to comments favoring a dynamic test

and to comments favoring the alternative of a voluntary standard.

b. Possible Role of Misuse and Alcohol in Tip-Over Incidents

Comment: One commenter alleged that any increase in mortality

related to these items is the direct result of misuse and the failure

of consumers to follow the appropriate instructions. The same commenter

stated that the fireworks industry cannot be held accountable for all

injuries, particularly when the item is being blatantly misused. The

commenter also claimed that many fireworks-related injuries involve

some level of intoxication by the operator and that the correlation

between alcohol use and injury should be considered in the hazard

analysis for any product.

Response: The incident reports do not indicate that the fatalities

involving large multiple-tube devices were a result of misuse. Rather,

they appear to have occurred during reasonably foreseeable use of the

product. The two fatalities occurred during family gatherings a day or

two after the July 4th holiday.

The labels on multiple-tube devices generally state that the device

should be placed on a solid level surface prior to firing. In one

fatality, concrete blocks were stacked in the yard as a staging area.

In the other fatality, the fireworks device had been placed on a board

so that it would fire over a lake. The use of the devices on either of

these surfaces appears to indicate concern with the appropriate

placement of the fireworks device prior to firing.

Thus, the known cases involving fatalities support the conclusion

that the users were attempting to follow the instructions for proper

placement of the devices. In addition, there is no indication that

alcohol was a factor in either of the deaths. Accordingly, the

Commission disagrees with the commenter's contention that consumer

misuse or intoxication was the cause of these accidents.

Comment: One commenter claimed that, based on a 1992 CPSC study of

hospital emergency-room-treated injuries, ``a major problem with

fireworks injuries were the result of consumer misuse.''

Response: The study cited does not support this proposition for the

devices at issue here. In discussing the category of Shells and Mines

(the major two types of devices included in the this rulemaking), the

report states that ``little can be said to characterize this category

of fireworks due to the small sample size (five investigations).

However, it appeared that the flight path of the projectile,

particularly when tip-over was involved, may be a major concern.'' [23]

There may well have been misuse of the multiple shell devices

associated with some of the injuries in the study. However, nothing in

the report indicated that the injuries could be attributed to any such

misuse, as opposed to erratic flight path, tip-over, or other problems

with the devices.

c. Section 15 of the CPSA

Comment: One commenter stated that the proposed rule is unnecessary

because existing regulations and section 15 of the Consumer Product

Safety Act (``CPSA'') are adequate. 15 U.S.C. 2064. Section 15

authorizes the Commission to take corrective actions regarding product

defects that create a substantial risk of injury to the public. See 16

CFR 1115.4, 1115.12 (e) and (g).

Response: Existing fireworks regulations require only a base-to-

height ratio of at least 1:3. 16 CFR 1507.4. All the devices tested by

CPSC that tipped over during actual use complied with this standard.

Therefore, this requirement does not adequately address the tip-over

hazard.

In addition, the ongoing problem of numerous section 15 recalls of

multiple-tube devices under section 15 of the CPSA due to tip-over

indicates that existing regulations are not effective. Under these

circumstances, a performance standard that effectively addresses the

problem for all devices is more appropriate than case-by-case

investigation and recall.

3. Selection of the Tip-Over Angle

Comment: One commenter stated that there is no logical or

statistically valid reason for choosing any particular angle as the

minimum angle required by the static test.

Response: In developing the proposed rule, the staff considered

specifying minimum tip angles as low as 45 degrees. However, as noted

above, the Commission concluded that, to provide a margin of safety and

to address the likelihood that the devices will not be used on level

ground, the static test should require that a device not tip at an

angle of 60 degrees.

It is possible that a fireworks device might be constructed that

would not tip over in a static test at 60 degrees but would tip over

under foreseeable conditions on grass. In fact, 1 of the 450 devices

tested by the Commission with a tip angle over 60 degrees did tip over

when tested on grass. Increasing the stringency of the static test to

address such hypothetical ``outliers'' would make the requirement

unduly restrictive for the vast majority of designs that are likely to

be marketed. If such easy-to-tip designs are marketed in the future,

the Commission will consider action under section 15 of CPSA. 15 U.S.C.

2064.

Comment: One commenter suggested a more lenient tilt test for items

that do not present as much of a tip-over hazard as other available

designs. The commenter stated that a more lenient tilt test was

especially appropriate for devices with tubes clustered in the center

of the base. The commenter asserted that multiple-tube items with tubes

clustered close to the center of the base will more likely fail the

static test, but be more stable when tested on foam or grass than

multiple-tube items with tubes near the edge of the base. The commenter

provided sketches to illustrate this point, and also suggested a

formula to determine the tilt angle based on the geometry of the

devices relative to the geometry of the base:

T=45+15 (d/b), where:

T is the tip angle in degrees; d is the length of the diagonal of a

square (or diameter of a circle) enclosing the tubes; and b is the

length of the diagonal of a square base or diameter of a circular base.

The commenter stated that preliminary testing supports the formula,

but provided no data and admits that further tests are needed.

Response: The staff of the Commission's Engineering Laboratory

agrees that there are configurations that could provide greater or

lesser stability for a fired multiple-tube device. The commenter lists

base size, base thickness, lift charge, and size of the aerial load as

relevant factors affecting stability. However, firing order and rate,

as well as other variables, also affect the dynamic stability of

multiple-tube devices.

The commenter supplied no data on which to evaluate the suggested

formula. The Commission has very limited data on the tip-over

characteristics of devices with tip angles in the range of 45 to 60

degrees. As explained above, the Commission selected the 60-degree tip

angle criterion based on a device with a tip angle of 50 to 51 degrees

that tipped over a large proportion of the time (33/51) when tested

dynamically on grass. In addition, various combinations of the factors

that affect tip-over could cause a device with

[[Page 13090]]

a similar configuration to tip over more readily than the tested

device. The suggested formula does not account for these other

factors--such as load, firing rate, etc. The Commission's criterion

does account for these factors by correlating tip angle to dynamic tip-

over on grass.

The commenter's formula is intended to be applied to devices with a

square or circular base. The device with the 50-51 degree tip angle

that had a high tip-over rate had a rectangular base. It is not clear

how, if at all, the commenter would apply the formula in this case.

However, it can be expected that the formula will produce tip-angle

criteria ranging between 50 and 60 degrees, depending on the

configuration. Available data do not show that such criteria would

provide an adequate margin of safety. Accordingly, the Commission is

not adopting this commenter's suggestion.

Comment: As explained above, the Commission selected the 60-degree

criterion based on the performance on grass of a large number of tests

of various large devices. Some comments questioned the adequacy of this

testing. One commenter asked why the Commission did not test the

devices that were recalled as a result of failing the 2-inch foam test

and the device known to have been involved in the death of a 3-year-old

boy. The same commenter suggested that CPSC conduct additional tests

comparing the static test to the dynamic test with foam. Another

commenter questioned why the Commission did not test a larger sampling

of the various multiple-tube devices, including the W-800 inserts with

a wooden base and a tube around the insert.

Response: In developing the proposed standard, the Commission

selected devices that represented a cross section of the devices

available at the time and that provided a range of tip-over rates. The

Commission considered design characteristics such as base size, firing

order, internal fuse-burn time, lift charge, shell mass, device shape,

center of gravity, and quality of materials and construction. This

cross-section of devices is sufficient to ensure that the test selected

by the Commission is reasonable.

Devices that had been previously recalled--as well as the device

involved in the death of the 3-year-old boy--were not available at the

time that the CPSC conducted its tests. It is expected that had they

been available for testing, they would have been among those devices

found to be unstable. However, the Commission believes that it is more

reasonable to test currently available devices, rather than devices

that are no longer manufactured or available.

Comment: Some commenters stated that there are devices that are

stable in actual use even though they do not comply with the proposed

rule. AFSL submitted test data to support this view. These commenters

asserted that the proposed rule unfairly penalizes such devices.

Response: As explained above, AFSL presented limited test data on

12 large multiple-tube devices (one device included in AFSL's testing

was actually a small device). Seven of these did not meet the 60-degree

tip angle, but did not tip over in AFSL's dynamic tests.

AFSL's testing was very limited--only one sample of each device on

three surfaces (concrete, 2-inch foam, and grass), and one device was

not even tested on grass. A single test is not sufficient to establish

the dynamic stability of a device. For example, a device that tips over

1 in 10 times may present a serious risk of injury, but there is only a

1-in-10 chance of observing a tip-over in a single test. In CPSC's

tests, the staff tested from 40 to 90 samples of each device. The

Commission cannot conclude based on AFSL's limited data that the seven

devices it tested are stable when operated on grass.

4. Static v. Dynamic Test

Introduction. As noted above, the Commission's requirement involves

inclining the device at an angle of 60 degrees while it is prevented

from sliding by a stop on the inclined supporting surface. If the

device does not tip over further at that angle, it complies with the

requirement. This is a static test; it is affected only by the location

of the center of gravity of the device with respect to the edge of the

device that is against the stop.

Comments: A number of commenters would prefer a dynamic test, which

would involve actually firing the device while it rests on a specified

supporting surface to see if the device tips over. The American

Pyrotechnic Association (``APA'') and AFSL stated that, although they

support a requirement for static stability, a static requirement is not

sufficient by itself to address the tip-over hazard. These two

organizations and other commenters stated that, in addition to a static

test, the proposed rule should require dynamic testing, either for all

large devices or for those with tip angles between 45 and 60 degrees.

Response: Under the FHSA, manufacturers must consider whether their

products pose a hazard during ``reasonably foreseeable handling and

use.'' The Commission considers operation of multiple-tube devices on

grass to be ``reasonably foreseeable.'' Further, the resilient and

variable nature of grass makes it more likely that a device will tip

over when fired from a grass surface than from other common supporting

surfaces, such as dirt or pavement. Thus, an adequate test should

address the hazard of tip-over of these devices when fired while

sitting on grass as well as on more forgiving surfaces.

A substantial problem with dynamic testing of these devices is that

grass is not a reproducible test surface. Even patches of grass that

appear to be identical can react differently to the forces produced

when a device is fired.

Foams of various characteristics have been suggested as suitable

test surfaces for determining whether a device will tip over when

fired. AFSL uses 2-inch thick medium-density foam in its tip-over

testing.

The staff considered whether foam is an adequate surrogate for

grass--that is, whether there is a consistent relationship between the

tip-over behaviors on grass and foam for a variety of devices. Based on

the CPSC's tests, however, there was no consistent relationship between

the tip-over rates measured on grass and foam. In fact, the tests

suggested that there may be cases where devices that do not tip over

when tested on foam may tip over frequently on grass.

The Commission concludes that, because of the absence of any

suitable test surface, the use of dynamic testing for devices,

regardless of their tip angle, is not presently feasible. However, the

results of any voluntary dynamic tests by industry may provide valuable

information when considered in conjunction with a device's tip angle.

And, as explained above, the Commission will examine whether devices

that tip over when fired despite passing the 60-degree tip-angle test

present a substantial product hazard under section 15 of the CPSA.

5. Dynamic Variations in Tip-Over Potential

Comment: One commenter noted that the potential for tip-over from

multiple-tube mine and shell devices is not equal among all of the

various shapes, sizes, and configurations of devices.

Response: The Commission agrees that the potential for dynamic tip-

over from multiple-tube fireworks devices can differ among the various

shapes, sizes, and configurations of devices with the same static tip

angle. For example, devices that have larger or heavier bases or

smaller lift (propellant) charges are less likely to tip over.

Nevertheless, for

[[Page 13091]]

the reasons explained above, the 60-degree tip-angle test is the best

means available to determine whether a multiple-tube device is

unreasonably likely to tip over when fired.

Comments on specific factors that may affect tip-over potential are

discussed below.

Comment: One commenter stated that the rate of firing of the

projectiles from the tubes can affect dynamic stability and that this

should be examined.

Response: The Commission agrees that the rate of firing--the time

between the firing of individual tubes--may affect the dynamic

stability of multiple devices. A multiple-tube device can become less

stable as a result of rapid sequential tube firings. In compliance

testing, the Commission considers whether the firing rate may

contribute to tip-over. The staff has discussed with AFSL the

possibility of incorporating into their standard a minimum time between

the firing of successive tubes. However, the rate of firing is only one

of many variables that affect the dynamic stability of multiple-tube

devices. The 60-degree tip-angle test requirement, which takes into

account several factors, is the best known way to address the tip-over

hazard.

Comment: Several commenters stated that, in addition to the static

test, the proposed rule should limit the lift charge--i.e., the

propellant powder weight--to 12 grams per tube. AFSL presented test

data showing that increasing the lift charge above the 12-gram limit

may decrease the dynamic stability of multiple-tube devices. A

specially made device (not commercially available), with 20 grams of

lift charge per tube, tipped over in one test on 2-inch foam. A similar

device with 12 grams of lift charge did not tip over in one test on

foam. Another specially-made device did not tip over in one test on

foam, even though the lift charge was increased to 20 grams.

Several commenters asked why the CPSC did not study the effects on

stability of the amount of lift charge in devices.

Response: U.S. Department of Transportation (``DOT'') regulations

permit a maximum of 20 grams of lift charge per tube. The AFSL

voluntary standard limits the lift charge to 12 grams per tube. The

proposed rule did not separately address lift charge. The DOT mandatory

20-gram upper limit and AFSL voluntary 12-gram upper limit are

unaffected by this rulemaking.

The staff measured the lift charge in all the devices that were

tested. The lift charges in the two devices that tipped over on grass

(before they were modified) were 3.6 and 4.7 grams per tube. The lift

charges in devices that did not tip over ranged from 4.7 to 11.6 grams

per tube. [6] These results do not support limiting the lift charge.

Devices with a lift charge greater than 12 grams per tube were not

available to the staff.

The lift charge is only one of the variables that affect dynamic

stability. Other variables include firing order, firing rate, weight,

the configuration of the tubes, and base dimensions. Further, the lift

force (or propellant force)--rather than the lift charge--relates more

directly to dynamic stability. The lift force depends on factors in

addition to the lift charge, such as the type of powder and the design

of the product. Again, the staff's data show that the dynamic

performance of the device is better predicted by a static test.

It may be possible to construct a device that will tip over in

actual use, even though it passes the 60-degree static stability test.

AFSL's tests suggest this may be the case. But, the small number of

tests conducted by AFSL (two devices, one test each) and the mixed

results it reported (one device with 20 grams of lift powder tipped

over on foam while another did not) are not adequate to support a

mandatory 12-gram limit on the lift charge.

Manufacturers, importers, and distributors must see that their

products do not pose a substantial product hazard. Increasing the lift

charge might increase the tendency of multiple-tube devices to tip over

during operation. Devices developed in the future that exceed 12 grams

of lift charge will be tested by the Commission. Any device that tips

over while functioning, even though it complies with the static test,

may present a substantial product hazard. As explained above, the

Commission may take enforcement action in such a case under section 15

of the CPSA. Thus, although the Commission lacks data to warrant a

mandatory limit at this time, the Commission encourages manufacturers

and importers to continue compliance with the voluntary limit of 12

grams of lift charge per tube since the amount of lift charge may

affect tip-over.

6. Other Advantages of a Static Test

Comment: The AFSL and the APA stated that they favor a static test,

as in the proposed standard, because it is safer to perform than

dynamic testing. One commenter stated that it appears that the

Commission proposed a standard based on a static test, in part, because

it is easier to perform than dynamic testing.

Response: The Commission proposed a mandatory standard based on the

static test because it adequately addresses the hazard and a suitable

dynamic test is not available. That the static test is easier and safer

to perform are additional advantages.

7. Other Alternatives to the Proposed Rule

a. Additional Labeling

Comment: One commenter suggested requiring the warning label on

multiple-tube devices to include a phrase such as, ``PLACE UPRIGHT ON

HARD, SMOOTH LEVEL SURFACE BEFORE IGNITING. DO NOT FIRE ON GRASS OR

OTHER UNSTABLE SURFACE.''

Response: The Commission's current labeling requirement for mine

and shell devices includes the following statement: ``Place on hard

smooth surface (or place upright on level ground, if more

descriptive).'' 16 CFR 1500.14(a)(7)(ix). Except for the admonition not

to fire on grass, the commenter's suggested label is equivalent to the

Commission's current requirement. As to the statement ``do not fire on

grass,'' it is likely that users will place these devices on whatever

surface is at the desired location, including grass. Thus, the

Commission cannot conclude that there would be significant safety

benefits from a label advising against use on grass. Furthermore, the

longer label statement suggested by this commenter could reduce the

extent to which the basic message is noticed and read by users.

Although the Commission lacks the evidence to mandate the ``do not fire

on grass'' statement, and questions its effectiveness, the Commission

would not object if manufacturers voluntarily supply such a statement

after the required label.

In addressing a product hazard, the most effective approach is to

design the hazard out of the product. A warning does not remove the

hazard; it only informs the consumer of the hazard. Some users may read

and follow the information on a warning label. However, fireworks are

frequently used at night when it is too dark for the user to read a

warning label. Fireworks also are often used at a party or celebration

in which users are unlikely to take the time to read and follow warning

labels. And, spectators, like the two victims killed by multiple-tube

devices that tipped over, probably will not have an opportunity to read

the label.

Even if consumers read and follow a warning label, the device may

tip over. In the two death incidents, the fireworks devices were placed

on hard, smooth surfaces and they still tipped over. The Commission

believes that the proposed

[[Page 13092]]

tip-over performance requirement for multiple-tube devices will result

in less hazardous multiple-tube devices.

b. Defer to AFSL's Voluntary Standard

i. Adequacy of the Voluntary Standard

Comments: Several commenters supported AFSL's voluntary standard.

One group of commenters stated that they would prefer that the

Commission allow the industry to adopt a voluntary standard, rather

than issue a mandatory standard. Specifically, one commenter referred

to AFSL's standard--i.e., the 2-inch foam test--and asserted that foam

is a standard, reproducible test surface, even though it is not an

adequate surrogate for grass. Another commenter questioned CPSC's

conclusion that the AFSL standard did not adequately address the tip-

over hazard. AFSL commented that the foam test is intended to simulate

a worst-case scenario and that, even though the foam test may not be

suitable for a mandatory standard, it adequately addresses the tip-over

hazard.

Response: AFSL's foam test has many substantial shortcomings. AFSL

does not specify the properties of the foam--such as compressibility,

resiliency, and density--that are essential for a reproducible

test.5 Neither does AFSL specify the environmental conditions,

such as temperature and wind speed, that may affect the test results,

or the number of devices to be tested. All of these parameters must be

specified before the foam test could be considered a standard,

reproducible test. And, perhaps most significantly, there is simply no

evidence of a consistent relationship between tip-over rates on grass

and foam. Thus, a test on foam would not be appropriate even if all the

test parameters were specified.

\5\ Although AFSL specifies medium-density foam, the definition

of ``medium'' may differ among foam suppliers.

---------------------------------------------------------------------------

AFSL has never released test results showing that 2-inch foam is a

worst-case surface compared to grass. CPSC has only limited data from

tests of devices on both 2-inch foam and grass. The Commission's

initial tests showed that the 3 different densities of 2-inch foam

tested had considerably higher tip-over rates than did grass.

The more extensive tests that the Commission performed on other

thickness of foam show that, depending on the device tested, the tip-

over rate on foam may be greater than, equal to, or less than that on

grass. Furthermore, the Commission's compliance testing in 1995 showed

a domestic device that tipped over on grass (1 of 5 tested), but not on

2-inch medium-density foam. Therefore, the Commission concludes that

the currently available information does not support the conclusion

that 2-inch foam (or foam in other thicknesses) is a worst-case test

surface that is consistently more stringent than grass.

As regards tip angle, the AFSL standard requires a tip angle of

only 18 degrees, whereas CPSC tests show that a tip angle of 60 degrees

is needed to reasonably prevent tip-over. The Commission concludes that

the AFSL standard's tip-angle provision does not adequately address the

tip-over hazard with large multiple-tube fireworks devices.

ii. Likelihood of Compliance With the Voluntary Standard

Comment: AFSL commented that a domestic testing program to allow

manufacturers to obtain certification for their products has not been

established and that the decision to follow the voluntary standard

rests solely with individual manufacturers. However, AFSL states that

its recent testing of large multiple-tube mine and shell devices

indicated that products received from known manufacturers ``appeared to

comply with the stability provisions of the AFSL standard.'' According

to AFSL, under its China-based testing and certification program, all

large multiple-tube mine and shell devices (with tubes larger than 1''

inside diameter) from participating firms are tested for compliance

with the voluntary standard. Any devices that fail to comply are

``withheld from shipment to the participating U.S. importer.''

Response: Even if using 2-inch thick medium-density foam were

effective, the Commission concludes that AFSL's voluntary standard

would not adequately reduce the risk of tip-over because it is unlikely

that there will be substantial industry compliance with that standard.

The AFSL standard was adopted in January 1993. However, the results

of CPSC's compliance testing indicate that these devices still tip

over. In fiscal year 1994, all 24 imported devices tested by CPSC, and

1 of 8 domestic devices, tipped over on either grass or 2-inch thick

medium density foam. Of the 32 devices tested on the foam, 25 tipped

over, and 4 of these also tipped over when tested on grass. In fiscal

year 1995, 22 of 27 imported devices and 1 of 5 domestic devices tipped

over. Of the 32 devices tested that year on 2-inch medium-density foam,

21 tipped over, and 10 tipped over when tested on grass. If there were

substantial compliance with the AFSL standard, these high rates of tip-

over on foam would not likely occur.

There is no information to support a conclusion that the rates of

compliance with the AFSL standard will improve. The Commission

concludes, therefore, that there will not likely be substantial

compliance with the AFSL standard.

c. A Ban of Large Devices

The Commission also considered whether large multiple-tube devices

should be banned entirely.

Comment: The National Fire Protection Association (``NFPA'')

generally has taken the position that fireworks should be used only by

licensed professionals. However, in this case, NFPA agreed with the

Commission's conclusion that limiting multiple-tube devices to

professionals would not eliminate the tip-over hazard. Some commenters

stated that the performance standard is preferable to a total ban of

large devices.

Response: The Commission agrees that a performance standard is the

most appropriate option in this case.

8. Effective Date

Comment: One commenter stated that manufacturers need 1 year to

redesign devices, use up current inventory, order new packaging, and

obtain Department of Transportation (``DOT'') approval for that

packaging.

Response: The Commission proposed an effective date of 6 months

after publication of a final rule. The rule will apply only to devices

first introduced into commerce or imported on or after that date. The

vast majority of fireworks are ordered by dealers from July to December

and delivered from December to June. The Commission expects that most

of the devices currently not complying with the standard can be

modified to meet it--e.g., by adding a base. Consequently, any devices

still in manufacturers' or importers' inventories on the effective date

would not be rendered useless.

According to the DOT official responsible for enforcing regulations

on new packaging, it may take 6 to 12 months for firms to obtain DOT

approval of changes to the devices, order new packaging, and obtain DOT

approval for that packaging. Larger firms are likely to be the ones

that will need the full 12-month period, due to the larger number of

models that could be affected.

Therefore, a number of firms will need an effective date that is

longer than the proposed date of 6 months, and up to 12 months,

following publication of the final rule in the Federal Register.

Accordingly, the Commission is extending the effective date to 12

months following publication. The final

[[Page 13093]]

rule will thus become effective March 26, 1997.

As noted previously, fireworks deliveries are concentrated in the

period December through June. The effective date falls within that

period. Therefore, it is likely that some but not all large multiple-

tube devices sold at retail for the 1997 summer season will comply with

the tip-angle requirement.

9. The Costs of the Regulation

a. Portion of Existing Large Devices To Be Changed by the Rule

Comment: AFSL presented test data with large multiple-tube mine and

shell devices from what it claims are all five domestic

manufacturers.6 Based on these tests, AFSL claimed that only 35

percent of domestic devices complied with the proposed rule (60-degree

tilt test), although all were stable in dynamic testing. The

Commission's preliminary regulatory analysis assumed that almost all

domestic devices would comply with the proposed rule.

\6\ Although AFSL stated that all the devices tested were

``domestically manufactured,'' some contained imported inserts. CPSC

classifies these devices as imports.

---------------------------------------------------------------------------

Response: AFSL's results contrast with CPSC staff's tests, in which

all domestic large multiple-tube devices met the proposed 60-degree

tip-angle test. Several aspects of AFSL's testing lead the Commission

to question AFSL's conclusions about the anticipated level of

compliance with the 60-degree tip-angle test.

AFSL presented test results for 13 models of multiple-tube mine and

shell devices. Device number 7 had an inside tube diameter of only 1.25

inches, and is not subject to the rule (which applies only to devices

with tube inner diameters measuring 1.5 inches or more). The devices

numbered 1, 2, 3, 12, and 13 are essentially imported devices or

``inserts'' to which wooden bases have been added. Based on AFSL's test

data, 5 of 7 (71 percent) large domestic multiple-tube devices will

satisfy the rule. The only two domestic devices tested by AFSL that

would fail to comply with the rule are devices 8 and 11, since their

tip angles were about 57 degrees. Both are new devices that were not

available at the time that the CPSC tests were conducted. Combining

AFSL's test data with CPSC's, 11 of 13 (85 percent) of large domestic

multiple-tube devices would comply with the rule.\7\ Therefore, the

Commission disagrees with AFSL's claim that only 35 percent of domestic

devices will comply with the proposed rule.

\7\ It appears that one device was tested by both AFSL and

CPSC. In combining the data, this device was counted only once.

---------------------------------------------------------------------------

b. Cost of Modifying Noncomplying Devices

Comment: One commenter argued that retail prices of the modified

devices would increase by 35 to 45 percent. The commenter did not

present any basis for this estimate.

Response: The Commission's cost estimates are based on an average

per-unit increase of 25-30 percent. These estimates were provided by

the National Fireworks Association (NFA). The NFA is the fireworks

trade association with the largest number of members, and the only one

with a large contingent of retailers. The NFA estimate is the best one

available to the Commission's staff.

10. Environmental Impact

Comment: One commenter stated that there would be a significant

environmental impact due to increased rubbish from the larger bases.

Response: The rule is expected to result in modifications to

devices representing sales of 100,000-to-175,000 items per year. [21]

Consequently, the rule will result in a similar number of larger or new

bases, and added packaging, being discarded. Most of these devices are

expected to be thrown away after use with other residential trash (as

is currently being done). The added costs of disposing of the bases and

packaging will be negligible. The environmental impact of disposing of

the relatively small amount of additional material required to provide

a base, or increase its size, will be negligible. The additional cost

to landfills of handling the extra rubbish also will be negligible.

H. The Standard

The Commission is issuing a standard requiring that multiple-tube

devices that have any tube measuring 1.5 inches (3.8 cm) or more in

inner diameter must have a minimum tip angle greater than 60 degrees.

Large multiple-tube devices that do not meet the tip-angle requirement

will be banned. The tip angle may be measured by placing the device on

a smooth, flat surface inclined at 60 degrees from the horizontal. The

device must not tip over at the 60-degree angle when tested at any edge

of the device.

An apparatus or ``testing block'' for testing multiple-tube devices

is illustrated in Figure 1 to Sec. 1507.12. The height and width of the

inclined plane (not including the portion of the plane below the

mechanical stop) must be at least 1 inch (2.54 cm) greater than the

largest dimension of the base of the device to be tested. The test

apparatus must be placed on a smooth, hard surface that is horizontal,

as determined by a spirit level or equivalent instrument. The

mechanical stop must be \1/16\ inch (1.6 mm) in height and

perpendicular to the inclined plane. The stop must be positioned

parallel to the bottom edge of the inclined plane in such a way that no

portion of the device to be tested or its base touches the horizontal

surface.

Any device that cannot be tested using the apparatus described

above, or that presents a tip-over hazard while functioning even though

it complies with the static test, may be examined to determine whether

it presents a ``substantial product hazard'' under section 15 of the

CPSA. 15 U.S.C. 2064. If the Commission determines that a substantial

product hazard exists, appropriate enforcement action may be taken. See

15 U.S.C. 2064.

J. Regulatory Analysis [22]

1. Introduction

The Commission is amending the FHSA fireworks regulations to

establish new stability requirements for multiple-tube fireworks

devices that have any tube with an inside tube diameter of 1.5 inches

or greater. These devices present a tip-over hazard when firing that

has resulted in an average of about one death every 3 years over the

period for which data are available.

The amendment will reduce the risk of injury and death from tip-

overs. Devices that do not remain stable at an angle 60 degrees or

below in prescribed tests will be banned hazardous substances under the

amendment. It is expected that devices that do not currently pass this

test will be able to comply by adding or enlarging a base.

In the Federal Register of July 1, 1994, the Commission issued an

ANPR to develop a mandatory requirement to address the tip-over hazard.

Although the ANPR addressed both large and small multiple-tube

fireworks devices, the notice of proposed rulemaking (NPR) published

July 5, 1995, covered only large multiple-tube devices.

To issue this amendment under the FHSA, the Commission is required

to publish preliminary and final regulatory analyses containing a

discussion of various factors. These factors include a description of

the potential benefits and potential costs of the rule, including any

benefits and costs that cannot be quantified in monetary terms, and an

identification of those most likely to receive the benefits or bear the

costs. The FHSA also requires a description of any reasonable

alternatives to the rule,

[[Page 13094]]

together with a summary description of their costs and benefits, and a

brief explanation of why such alternatives were not chosen.

2. Background

Large multiple-tube devices became popular in the mid-1980's. These

devices typically consist of three or more tubes fused in a series to

fire sequentially; these tubes are grouped together, sometimes on top

of a wooden base. The devices are designed to fire aerial shells,

comets, or mines producing visual and audible effects from non-

reloadable tubes. They are among the largest fireworks available for

direct consumer use.

The National Fireworks Association (NFA) reports that retail sales

of these devices are between $24 million and $36 million annually, with

an estimated 400,000 to 700,000 units sold per year. Prices range from

$30 to $130 per unit, with most devices priced in the $50-$60 range.

The NFA reports that domestic devices account for about 75 percent of

the market by dollar value, and somewhat less by unit sales. There may

be hundreds of firms engaged in manufacturing, importing, and

distributing these fireworks. Imported devices are primarily

manufactured in China, and may go through several wholesalers before

reaching the retail vendor.

To comply with the standard, devices that do not have a base would

have to add one, and some currently used bases would have to be

enlarged. However, consumers are not likely to perceive any significant

loss of enjoyment as a result. While some devices may be discontinued,

loss of consumer choice would be minimized by the availability of

devices that do comply with the standard. Smaller (less than 1.5 inch

ID) multiple-tube devices are not covered by the rule and would

continue to be available without any change.

3. Regulatory Analysis of the Amendments

a. Potential Benefits. One of the potential risks of injury

associated with large multiple-tube fireworks devices results from the

tip-over hazard. The Commission's Directorate for Epidemiology and

Health Sciences reports two deaths associated with the tip-over hazard

from January 1, 1988, through December 1993. This averages to about 1

death every 3 years. The Commission has received no reports of injuries

with the product.

The Commission is issuing a performance standard that will require

these devices to have a minimum tip angle greater than 60 degrees.

According to the Commission's tests, devices that do not tip over at

this angle are not likely to tip while functioning. Thus, the

Commission believes that devices meeting this requirement are not

likely to fall over while firing, thereby minimizing this risk of death

and injury to operators or spectators. The avoidance of these deaths

and injuries represents the potential societal benefits of the proposed

amendments.

The costs per life saved of this rule are estimated to be between

$4.5 and $8 million. These costs are within the range of statistical

values of life suggested in the recent professional literature. [22]

Given that no significant substitution of more hazardous products is

expected, no offsetting reduction in these safety benefits is

anticipated. To the extent that nonfatal injuries are avoided, the

potential benefits would be somewhat higher.

b. Potential Costs. Most devices that already have bases will not

have to be modified to meet the amendments. The devices that are not

expected to need to be modified are generally manufactured domestically

and, according to the NFA, account for at least 75 percent of the

retail dollar volume of the market. It is expected that most of the

remaining devices (mainly imports) will be modified to meet the

amendments, with a resulting increase in cost of between 25 to 30

percent per modified unit.8

\8\ Trade and industry sources report that modifying the

devices would add about 25 to 30 percent to production costs

(although one commenter on the NPR stated that the per-unit cost

increase would be 35 to 45 percent). Various sales catalogs also

indicate that comparable devices without bases are significantly

less expensive.

---------------------------------------------------------------------------

In its comments responding to the NPR, AFSL reported that for the

43 units it examined, 65 percent did not meet the 60-degree tip-angle

test. The Commission is not using AFSL's estimate of 35 percent

compliance with the tip-angle test, since the Commission's staff raised

several questions about the accuracy of AFSL's estimate. Thus, the

Commission continues to use the industry-wide data provided by NFA to

estimate the portion of devices that would require modification (25

percent).

Assuming costs are passed on to consumers (as expected), the total

annual cost to consumers of modifying the affected devices would be

between $1.5 million and $2.7 million. While certain devices may be

discontinued, the loss of consumer choice would be minimized by the

availability of close substitutes--i.e., other large multiple-tube

devices that comply with the amendments. Additionally, since most

suppliers of currently noncomplying devices are expected to maintain

current sales levels and pass on costs to consumers, no significant

adverse impact is expected in the suppliers' competitive positions.

If the changes eliminate all deaths associated with these devices,

the cost per life saved would be between about $4.5 and $8 million.

This is within the range of statistical values of life suggested in the

recent professional literature. [22]

4. Alternatives to the Rule

The Commission considered several alternatives to the performance

standard issued below, including a product ban, deferral to the

voluntary standard, and additional labeling.

a. Product Ban. The expected benefits to society of banning all

large multiple-tube devices would be one life saved every 3 years, the

same as the potential benefits of the amendments. However, costs to

society of a ban (as opposed to the performance standard) in terms of

lost utility would be greater, because under a ban consumers would not

be able to use large multiple-tube devices.

Large multiple-tube devices are unique with respect to the height

and duration of their displays. There are no close substitutes for the

product. Single-tube devices are available, but they do not provide the

rapid sequential display of multiple-tube devices. The lost utility to

consumers of not being able to use large multiple-tube devices cannot

be measured precisely. However, the fact that consumers are willing to

spend $24-$36 million annually to buy these devices suggests that the

lost utility could be substantial.

The Commission believes that a ban of all large multiple-tube

devices is not necessary, because a performance standard will likely

achieve similar benefits with lower costs.

b. Defer to the Voluntary Standard. Another alternative is for the

Commission to take no mandatory action, and to depend on a voluntary

standard.

The AFSL revised its standard for mines and shells on an interim

basis on January 29, 1993, and adopted it on September 5, 1995. In

order to address the potential tip-over hazard associated with

multiple-tube fireworks devices, AFSL's Voluntary Standard for Mines

and Shells--Single or Multiple Shot requires that large multiple-tube

devices not tip over (except as the result of the last shot) when fired

on a 2-inch thick medium-density foam pad. [14] However, the Commission

has concerns about the adequacy of the provisions of, and the level of

conformance to, the AFSL standard.

[[Page 13095]]

The Commission also does not believe that AFSL's existing voluntary

standard adequately reduces the risk of injury due to large devices

tipping over while functioning. The Commission's tests using

polyurethane foam did not find sufficient agreement between tip-over

performance on foam and on grass. The Commission has no data that would

support AFSL's dynamic test. As explained in section G above, the test

results AFSL submitted in response to the NPR were limited and the

Commission does not believe they show that this dynamic test is

reliable.

In addition, even if the AFSL standard were effective, the

Commission concludes that compliance with the standard would not be

adequate. The majority of large multiple-tube devices are domestic. In

the NPR, the Commission stated that according to AFSL, not a single

domestically manufactured device has been certified as complying with

the AFSL standard. In comments responding to the NPR, AFSL stated that

their standards are voluntary ``and the decision to comply with the

standards rests solely with individual manufacturers.'' However, the

Commission must have assurance of an adequate level of compliance with

a voluntary standard in order to depend on that standard to reduce a

risk. AFSL's limited testing conducted in response to the NPR does not

substitute for an ongoing and comprehensive testing program.

AFSL reports that some shipments of imported large multiple-tube

devices have been tested and certified in China this year and that,

since January 1994, 30 percent of the lots it tested were rejected for

failure to comply with the AFSL standard. However, the results of

CPSC's compliance testing indicate that multiple-tube devices still tip

over while functioning in dynamic tests on grass. In fiscal year 1994,

all 24 imported devices the Commission tested, and 1 of 8 domestic

devices, tipped over while functioning. In fiscal year 1995, 22 of 27

imported devices and 1 of 5 domestic devices tipped over. [19]

c. Additional Labeling

The current product has extensive labeling. The text of the labels

required by the Commission is quoted in section D above. One

alternative available to the Commission is to add further warning or

instructional labeling to large multiple-tube devices or to modify the

existing warning. Although this may have less impact on manufacturers

and importers than a performance standard, the Commission believes that

any additional or altered labeling is unlikely to be effective in

reducing the risk of injury.

Fireworks are frequently used at night, reducing the likelihood

that warning labels will be read. The fact that fireworks are commonly

used at parties or celebrations further reduces the likelihood that the

user will read and follow a warning label. Moreover, tip-over may occur

even if the user reads and follows the warning label. In both incidents

involving large multiple-tube devices, the victims were spectators who

were approximately 40 feet (12 meters) away from the device, which they

probably believed was a safe distance. The devices were placed on

smooth, hard surfaces, although one was angled to shoot over a lake. In

light of these facts, it is unlikely that a warning label would have

prevented these deaths. [1, Tab E]

K. Regulatory Flexibility Certification

Under the Regulatory Flexibility Act, 5 U.S.C. Secs. 601-612,

agencies generally are required to prepare proposed and final

regulatory flexibility analyses describing the impact of the rule on

small businesses and other small entities. However, these analyses are

not required if the head of the agency certifies that the rule will not

have a significant effect on a substantial number of small entities. As

described below, the Commission has analyzed the potential effect of

the amendment on industry.

The Commission has determined that the proposed standard will not

have a significant impact on a substantial number of small businesses.

The devices subject to the standard constitute less than 1 percent of

the overall fireworks market. The foreign firms that make the types of

devices subject to this rule that are likely to require modification in

order to comply also make other types of fireworks. Only a small

portion of the total production of these firms involves the large

multiple-tube devices subject to the rule. Thus, the Commission

certifies that no significant adverse impact on a substantial number of

small firms, or other entities, will result from the amendment issued

below.

L. Environmental Considerations

The Commission's regulations governing environmental review

procedures state that the amendment of rules or safety standards

establishing design or performance requirements for products normally

have little or no potential for affecting the human environment. 16 CFR

1021.6(c)(1). The Commission does not foresee that this amendment to

the existing fireworks regulations will involve any special or unusual

circumstances that would alter this conclusion. The Commission

determines, therefore, that no significant environmental effects will

result from the standard. Accordingly, no environmental assessment or

environmental impact statement is required in this proceeding.

M. Effective Date

The rule will take effect in 1 year and will apply to multiple-tube

fireworks devices with any tube measuring 1.5 inches or more in inner

diameter that first enter commerce or are imported on or after the

effective date. However, provisions may be stayed by the filing of

proper objections. Notice of the filing of any objections or lack

thereof will be given by publication in the Federal Register.

List of Subjects in 16 CFR Part 1500

Consumer protection, Hazardous materials, Hazardous substances,

Imports, Infants and children, Labeling, Law enforcement, and Toys.

Conclusion

For the reasons given above, the Commission finds that cautionary

labeling required by the FHSA is not adequate for multiple-tube devices

having any tube 1.5 inches (3.8 cm) or larger in inner diameter and

having a minimum tip angle larger than 60 degrees. Further, in order to

protect the public health and safety and due to the degree and nature

of the tip-over hazard presented by these devices, it is necessary to

keep them out of commerce if they fail to meet this standard. Thus, the

Commission amends Parts 1500 and 1507 Title 16 of the Code of Federal

Regulations as follows:

PART 1500--[AMENDED]

1. The authority for Part 1500 continues to read as follows:

Authority: 15 U.S.C. 1261-1278

.2. Section 1500.17 is amended by adding a new paragraph (a)(12) to

read as follows:

Sec. 1500.17 Banned hazardous substances.

* * * * *

(a) * * *

(12) (i) Large multiple-tube devices. Multiple-tube mine and shell

fireworks devices that first enter commerce or are imported on or after

[insert date that is 1 year after publication], that have any tube

measuring 1.5 inches (3.8 cm) or more in inner diameter, and that have

a minimum tip angle greater than 60 degrees when tested in accordance

with the procedure of Sec. 1507.12 of this part.

[[Page 13096]]

(ii) Findings. (A) General. In order to issue a rule under the

section 2(q)(1) of the FHSA, 15 U.S.C. 1261(q)(1), classifying a

substance or article as a banned hazardous substance, the FHSA requires

the Commission to make certain findings and to include these in the

regulation. These findings are discussed in paragraphs (a)(12)(ii)(B)

through (D) of this section.

(B) Voluntary standard. (1) One alternative to the tip-angle

requirement that the Commission considered is to take no mandatory

action, and to depend on a voluntary standard. The American Fireworks

Safety Laboratory (AFSL) has a standard for mines and shells intended

to address the potential tip-over hazard associated with multiple-tube

fireworks devices. AFSL's Voluntary Standard for Mines and Shells--

Single or Multiple Shot requires that large multiple-tube devices not

tip over (except as the result of the last shot) when shot on a 2-inch

thick medium-density foam pad. The Commission cannot conclude that

AFSL's existing voluntary standard adequately reduces the risk of

injury from large devices that tip over while functioning. The

Commission's tests using polyurethane foam did not find sufficient

agreement between performance on foam and on grass. No other data are

available to show that this dynamic test is reliable.

(2) In addition, even if the AFSL standard is effective, the

Commission does not believe that compliance with the standard will be

adequate. AFSL reports that it has been testing in accordance with its

standard since January 1994. However, the results of CPSC's compliance

testing indicate that multiple-tube devices still tip over while

functioning. In fiscal year 1994, all 24 imported devices the

Commission tested, and 1 of 8 domestic devices, tipped over while

functioning. In fiscal year 1995, 22 of 27 imported devices and 1 of 5

domestic devices tipped over during Commission testing. The Commission

finds that there is unlikely to be substantial compliance with the

voluntary standard applicable to multiple-tube devices.

(C) Relationship of benefits to costs. The Commission estimates

that the 60-degree tip-angle standard will eliminate the unreasonable

tip-over risk posed by these devices. This will provide benefits of

saving one life about every 3 years, and preventing an unknown number

of nonfatal injuries. The annual cost of modifying affected devices is

estimated to be between $1.5 million and $2.7 million. The Commission

finds that the benefits from the regulation bear a reasonable

relationship to its costs.

(D) Least burdensome requirement. The Commission considered the

following alternatives: a ban of all multiple-tube devices with inner

tube diameters 1.5 inches or greater; a dynamic performance standard;

additional labeling requirements; and relying on the voluntary

standard. Although a ban of all large multiple-tube devices would

address the risk of injury, it would be more burdensome than the tip-

angle standard. The Commission was unable to develop a satisfactory

dynamic standard that would reduce the risk of injury. Neither

additional labeling requirements nor reliance on the voluntary standard

would adequately reduce the risk of injury. Thus, the Commission finds

that a standard requiring large multiple-tube devices to have a minimum

tip angle greater than 60 degrees is the least burdensome requirement

that would prevent or adequately reduce the risk of injury.

PART 1507--[AMENDED]

1. The authority for Part 1507 continues to read as follows:

Authority: Sec. 2(q)(1)(B), (2), 74 Stat. 374 as amended 80

Stat. 1304-1305; (15 U.S.C. 1261); sec. 701(e), 52 Stat. 1055 as

amended; 21 U.S.C. 371(e)); sec. 30(a), 86 Stat. 1231; 15 U.S.C.

2079(a)).

2. Part 1507 is amended by adding a new Sec. 1507.12 to read as

follows:

Sec. 1507.12 Multiple-tube Fireworks Devices.

(a) Application. Multiple-tube mine and shell fireworks devices

with any tube measuring 1.5 inches (3.8 cm) or more in inside diameter

and subject to Sec. 1500.17(a)(12) of this part shall not tip over when

subjected to the tip-angle test described in this section.

(b) Testing procedure. The device shall be placed on a smooth

surface that can be inclined at 60 degrees from the horizontal, as

shown in Figure 1 of this section. The height and width of the inclined

plane (not including the portion of the plane below the mechanical

stop) shall be at least 1 inch (2.54 cm) greater than the largest

dimension of the base of the device to be tested. The test shall be

conducted on a smooth, hard surface that is horizontal as measured by a

spirit level or equivalent instrument. The mechanical stop on the

inclined plane shall be 1/16 inches (1.6 mm) in height and

perpendicular to the inclined plane. The stop shall be positioned

parallel to the bottom edge of the inclined plane and so that no

portion of the device to be tested or its base touches the horizontal

surface. The device shall not tip over when the plane is inclined at

60-degrees from the horizontal. The procedure shall be repeated for

each edge of the device. Figure 1 to Sec. 1507.12

BILLING CODE 6355-01-P

[[Page 13097]]

[GRAPHIC] [TIFF OMITTED] TR26MR96.011

BILLING CODE 6355-01-C

Dated: March, 18, 1996.

Sadye E. Dunn,

Secretary, Consumer Product Safety Commission.

Reference Documents. (The following list of documents will not

be printed in the Code of Federal Regulations.)

The following documents contain information relevant to this

rulemaking proceeding and are available for inspection at the Office

of the Secretary, Consumer Product Safety Commission, Room 502, 4330

East-West Highway, Bethesda, Maryland 20814:

1. Multiple-tube Mine and Shell Fireworks Devices: Advance

Notice of Proposed Rulemaking; Request for Comments and Information,

59 Fed. Reg. 33928 (July 1, 1994).

2. Briefing Package: Multiple-tube Mine and Shell Fireworks

Devices, Consumer Product Safety Commission, May 31, 1994.

3. Briefing Memorandum on Multiple-tube Mine and Shell Fireworks

Devices, from Ronald L. Medford, EXHR and Michael Babich, EHHE, to

the Commission, June 8, 1995.

4. Memorandum from Michael Babich, Project Manager, HSHE,

``Responses to Public Comments on Multiple-tube Mine and Shell

Devices,'' May 22, 1995.

5. Memorandum from Leonard Schachter, EPHA, to Michael Babich,

HSHE, ``Annual Estimated Injuries Associated with Multiple-tube Mine

and Shell Fireworks Devices,'' June 1, 1995.

6. Memorandum from James Carleton and Jay Sonenthal, LSHS, to

Michael Babich, HSHE, ``Results for Dynamic Stability Testing of

Large Multiple-tube Mine and Shell Devices,'' May 18, 1995.

7. Memorandum from Thomas Caton, ESME, to Michael Babich, HSHE,

``Fireworks Testing: Test Surface Roughness,'' May 22, 1995.

8. Report from Terry Kissinger, EPHA, to Michael Babich, HSHE,

``A Comparison of the Tip-over Performances of Multiple-tube Mine

and Shell Devices on Grass and Foam,'' January 1995.

9. Memorandum from George F. Sushinsky, LSEL, to Michael Babich,

HSHE, ``Dimensional and Stability Measurements of Fireworks,'' March

10, 1995.

10. Memorandum from George F. Sushinsky, LSEL, to Michael

Babich, HSHE, ``Tip Angle Measurements of a Device with a Plastic

Base,'' April 13, 1995.

11. Memorandum from Jay Sonenthal, LSHL, to Michael Babich,

HSHE, ``Test of a Device with a Plastic Base,'' May 22, 1995.

12. Memorandum from Sam Hall, CERM, to Michael Babich, HSHE,

``Acceptable Tipover Rate for Multiple-tube Devices,'' November 21,

1994.

13. Memorandum from Anthony Homan, ECPA, to Michael Babich,

HSHE, ``Multiple-tube Mine and Shell Fireworks Devices--Regulatory

Analysis,'' May 18, 1995.

14. Memorandum from Sam Hall, CERM, to Michael Babich, HSHE,

``AFSL's Interim Voluntary Standard for Large Multiple-tube Mine and

Shell Devices and Staff's Proposed Mandatory Static Performance

Standard, May 25, 1995.

15. Product and Performance Standard for Mines and Shells--

Single or Multiple Shot,'' Version 1.1, American Fireworks Standards

Laboratory, Bethesda, Maryland, January 28, 1993.

16. Memorandum from Neal Gasser, LSHL, to Michael Babich, HSHE,

``Additional Tests of Multiple-tube Mine and Shell Devices,'' June

8, 1995.

17. Briefing Memorandum on Multiple-tube Mine and Shell

Fireworks Devices--Final Rule, from Michael Babich, EHHE, and Ronald

L. Medford, HIR, to the Commission, January 23, 1996.

18. Memorandum from Michael A. Babich, EHHE, ``Responses to

Comments on Multiple-tube Mine and Shell Devices,'' January 16,

1996.

19. Memorandum from Samuel B. Hall, CRM, to Michael Babich,

HSHE, ``Compliance Tests of Large Multiple-tube Mine and Shell

Devices under FY 1994 and FY 1995 Fireworks Enforcement Programs,''

December 8, 1995.

20. Memorandum from Leonard Schacter, EHHA, to Michael Babich,

HSHE, ``Annual Estimated Injuries Associated with Multiple-tube Mine

and Shell Fireworks Devices,'' November 1, 1995.

21. Memorandum from Anthony Homan, ECPA, to Michael Babich,

HSHE, ``Multiple-tube Mine and Shell Fireworks Devices--Final

Regulatory Analysis,'' January 16, 1996.

22. Viscusi, W.K., ``The Value of Risks to Life and Health,''

Journal of Economic Literature, December 1993.

23. Kissinger, T.L., Fireworks Injuries--results of a 1992 NEISS

study. U.S. Consumer Product Safety Commission, Washington, DC

20207. September 1993.

[FR Doc. 96-6857 Filed 3-25-96; 8:45 am]

BILLING CODE 6355-01-P

This is a copy of a public record, reproduced as it was published. It is not legal advice, and it may not be the version a court would rely on. Check the official source before you cite it.

A word about cookies

We need a few to keep you signed in and the library working. The rest help us see which pages people use and where they get stuck. They stay off unless you say yes.