Approval and Promulgation of Implementation Plans; Illinois

Federal RegisterMar 21, 1995

Ask Donna

What actually matters in this document.

Text

ENVIRONMENTAL PROTECTION AGENCY

40 CFR Part 52

[IL79-1-6616A; FRL--5167-4]

Approval and Promulgation of Implementation Plans; Illinois

AGENCY: Environmental Protection Agency.

ACTION: Direct final rule.

-----------------------------------------------------------------------

SUMMARY: The United States Environmental Protection Agency (USEPA)

approves requested revisions to Chicago ozone Federal Implementation

Plan (FIP) as it pertains to the following sources: General Motors

Corporation, Electro-Motive Division Plant (GMC Electro-Motive),

LaGrange, Illinois; Minnesota Mining and Manufacturing Corporation

(3M), Bedford Park, Illinois; Replogle Globes, Inc. (Replogle);

Broadview, Illinois; Candle Corporation of America (CCA), Chicago,

Illinois; Nalco Chemical Company (Nalco) Bedford Park, Illinois

Clearing Plant; Parisian Novelty Company (Parisian), Chicago, Illinois;

Meyercord Corporation (Meyercord), Carol Stream, Illinois; Wallace

Computer Services, Inc. (Wallace) Printing and Binding Plant, Hillside,

Illinois; and the General Packaging Products, Inc. (GPP) Chicago,

Illinois. This action lists the FIP revisions USEPA is approving and

incorporates the relevant material into the Code of Federal

Regulations. The rationale for the approval is set forth in this final

rule; additional information is available at the address indicated

below. Elsewhere in this Federal Register, USEPA is proposing approval,

soliciting public comment, and offering an opportunity for a public

hearing on these requested FIP revisions. If adverse comments are

received or a public hearing is requested on this direct final rule,

USEPA will withdraw this final rule and address the comments received

in response to this final rule in the final rule on the proposed rule

published in the proposed rules section of this Federal Register.

Unless this final rule is withdrawn, no further rulemaking will occur

on this requested FIP revision.

EFFECTIVE DATE: This action will be effective May 22, 1995 unless

notice is received by April 20, 1995 that someone wishes to submit

adverse comments. If the effective date is delayed, timely notice will

be published in the Federal Register.

ADDRESSES: Written comments can be mailed to: J. Elmer Bortzer, Chief,

Regulation Development Section (AR-18J), Regulation Development Branch,

Air and Radiation Division, U.S. Environmental Protection Agency, 77

West Jackson Boulevard, Chicago, Illinois 60604.

Docket: Pursuant to sections 307(d)(1) (B) and (N) of the Clean Air

Act (Act), 42 U.S.C. 7607(d)(1) (B) and (N), this action is subject to

the procedural requirements of section 307(d). Therefore, USEPA has

established a public docket for this action, A-94-39, which is

available for public inspection and copying between 8 a.m. and 4 p.m.,

Monday through Friday, at the following addresses. We recommend that

you contact Fayette Bright before visiting the Chicago location and

Rachel Romine before visiting the Washington, D.C. location. A

reasonable fee may be charged for copying.

The United States Environmental Protection Agency, Region 5,

Regulation Development Branch, Eighteenth Floor, Southeast, 77 West

Jackson Boulevard, Chicago, Illinois, 60604, (312) 886-6069.

United States Environmental Protection Agency, Docket No. A-94-39,

Air Docket (LE-131), Room M1500, Waterside Mall, 401 M Street, S.W.,

Washington, D.C. 20460, (202) 245-3639.

FOR FURTHER INFORMATION CONTACT:

Steven Rosenthal, Environmental Engineer (312) 886-6052.

SUPPLEMENTARY INFORMATION: On June 29, 1990, USEPA promulgated a FIP

requiring Reasonably Available Control Technology (RACT) to control the

emission of Volatile Organic Compounds (VOCs) in six counties in the

Chicago metropolitan area. 55 FR 26818, codified at 40 CFR 52.741. In

determining the applicability of some of these regulations to

particular sources, USEPA used the concept of ``maximum theoretical

emissions'' (MTE), which is defined as ``the quantity of volatile

organic material emissions that theoretically could be emitted by a

stationary source before add-on controls based on the design capacity

or maximum production capacity of the source and 8760 hours per year *

* * at ``55 FR 26860, 40 CFR 52.741(a). Relief for otherwise subject

sources is available through a site-specific State Implementation Plan

(SIP) or FIP revision that limits emissions to below the applicable

cutoff by operational or production limitations.

The sources identified in Table 1 have requested that USEPA approve

production or operational limitations that will keep their emissions

below the applicability cutoff of the rule to which they would

otherwise be subject. Production limits are restrictions on the amount

of final product which can be manufactured or otherwise produced at a

source. Operational limits are all other restrictions on the manner in

which a source is run, including hours of operation and amount and type

of raw material consumed. Production and operational limits must be

stated as conditions that can be enforced independently of one another.

FIP revisions which limit VOC emissions to less than 100 tons VOC

per year have been requested by the following nine companies.

[[Page 14900]]

Table 1.--Requests for Federally Enforceable Operating Restrictions

----------------------------------------------------------------------------------------------------------------

Date of

State Pollutant Subject matter Source submission

----------------------------------------------------------------------------------------------------------------

Illinois............. VOM............. Chicago Ozone FIP........... GMC Electro-Motive.......... \1\NA

Illinois............. VOM............. Chicago Ozone FIP........... 3M.......................... 08/29/91

Illinois............. VOM............. Chicago Ozone FIP........... Replogle.................... 10/17/91

Illinois............. VOM............. Chicago Ozone FIP........... CCA......................... 09/05/91

Illinois............. VOC............. Chicago Ozone FIP........... Nalco....................... 02/23/93

Illinois............. VOM............. Chicago Ozone FIP........... Parisian.................... 04/09/92

Illinois............. VOM............. Chicago Ozone FIP........... Meyercord................... 08/12/94

Illinois............. VOM............. Chicago Ozone FIP........... Wallace..................... 09/24/92

Illinois............. VOM............. Chicago Ozone FIP........... General Packaging........... 10/02/92

----------------------------------------------------------------------------------------------------------------

\1\The General Motors revision is based on materials submitted to USEPA on February 28, 1991 and May 10, 1991,

in connection with resolution of General Motors Corp. v. USEPA, No. 90-2889 (7th Cir.).

USEPA has determined that these FIP revision requests comply with

all applicable requirements of the Act and USEPA policy and regulations

concerning such revisions. The USEPA, therefore, grants these requests.

Because USEPA considers this action noncontroversial and routine,

we are approving it without prior proposal. The action will become

effective on May 22, 1995. However, if we receive adverse comments or a

request for a public hearing by April 20, 1995, then USEPA will publish

a notice that withdraws this action. If no request for a public hearing

has been received, USEPA will address the public comments received in

the final rule on the requested SIP revision which has been proposed

for approval in the proposed rules section of this Federal Register. If

a public hearing is requested, USEPA will publish a proposed rule

announcing a public hearing and reopening the public comment period

until 30 days after the public hearing. At the conclusion of this

additional public comment period, USEPA will publish a final rule

responding to the public comments received and announcing final action.

The Office of Management and Budget has exempted this regulatory

action from Executive Order 12866 review.

Under the Regulatory Flexibility Act, 5 U.S.C. 600 et seq., USEPA

must prepare a regulatory flexibility analysis assessing the impact of

any proposed or final rule on small entities. 5 U.S.C. 603 and 604.

Alternatively, USEPA may certify that the rule will not have a

significant economic impact on a substantial number of small entities.

Small entities include small businesses, small not-for-profit

enterprises, and government entities with jurisdiction over populations

of less than 50,000.

Under Section 307(b)(1) of the Clean Air Act, petitions for

judicial review of this action must be filed in the United States Court

of Appeals for the appropriate circuit by May 22, 1995. Filing a

petition for reconsideration by the Administrator of this final rule

does not affect the finality of this rule for the purposes of judicial

review nor does it extend the time within which a petition for judicial

review may be filed, and shall not postpone the effectiveness of such

rule or action. This action may not be challenged later in proceedings

to enforce its requirements. (See section 307(b)(2).)

List of Subjects in 40 CFR Part 52

Environmental protection, Air pollution control, Intergovernmental

relations, Volatile organic compound, Volatile organic material.

Dated: February 28, 1995.

Carol M. Browner,

Administrator.

Part 52, chapter I, title 40 of the Code of Federal Regulations is

amended as follows:

PART 52--[AMENDED]

1. The authority citation for part 52 continues to read as follows:

Authority: 42 U.S.C. 7401-7671q.

Subpart O--Illinois

2. Section 52.741 is amended by adding paragraphs (e)(8), (h)(6),

(u)(6), (u)(7), (v)(6), (x)(6), (x)(8), (x)(9), (x)(10), (x)(11),

(x)(12) and (x)(13) read as follows:

Sec. 52.741 Control strategy: Ozone control measures for Cook, Du

Page, Kane, Lake, McHenry and Will Counties.

* * * * *

(e) * * *

(8) The control requirements in this paragraph apply to the wood

coating line, which coats wooden globe stand components, at Replogle

Globes, Inc. (Replogle) Broadview facility in Cook County, Illinois,

instead of the control requirements in paragraphs (e)(1) and (e)(2) of

this section. Compliance with this paragraph must be demonstrated

through the applicable coating analysis test methods and procedures

specified in paragraph (a)(4)(i) of this section.

(i) After October 6, 1991, no coatings shall at any time be applied

which exceed the following emission limitations for the specified

coating.

(A) 6.59 pounds (lbs) Volatile Organic Material (VOM) per gallon of

stain (minus water and any compounds which are specifically exempted

from the definition of VOM) as applied to coat wooden globe stand

components. Such stain consists of #9250 Walnut NGR Stain (RGI

#W06000100), #9974 Cherry NGR Stain (RGI #W06003500) and #9943 Ash NGR

Stain (RGI #W06003600). The Administrator must be notified at least ten

(10) days prior to the use of any replacement stains.

(B) 5.53 lbs VOM per gallon of Sanding Sealer (minus water and any

compounds which are specifically exempted from the definition of VOM)

as applied to coat wooden globe stand components. Such sealer consists

of #15304 High Build Sanding Sealer (RGI #W06003700). The Administrator

must be notified at least ten (10) days prior to the use of any

replacement sanding sealer.

(C) 5.20 lbs VOM per gallon of lacquer (minus water and any

compounds which are specifically exempted from the definition of VOM)

as applied to coat wooden globe stand components. Such lacquer consists

of #15352 High Build Lacquer (RGI #W06003300). The Administrator shall

be notified at least ten (10) days prior to the use of any replacement

lacquer.

(ii) After October 6, 1991, the volume of coatings used shall not

exceed the following:

(A) 5,000 gallons per year total for all coatings specified in

paragraph (e)(8)(i)(A) of this section. The yearly volume of coatings

used are to be calculated as follows:

(1) Compute the volume of specified coating used each month by the

15th of the following month. [[Page 14901]]

(2) By the 15th of each month, add the monthly coating use for the

12 previous months (to obtain the yearly volume of coatings used).

(B) 4,000 gallons per year total for all coatings specified in

paragraph (e)(8)(i)(B) of this section. The yearly volume of the

coatings used are to be calculated as specified in paragraphs

(e)(8)(ii)(A)(1) and (e)(8)(ii)(A)(2) of this section.

(C) 5,000 gallons per year total for all coatings specified in

paragraph (e)(8)(i)(C) of this section. The yearly volume of coatings

used are to be calculated as specified in paragraphs (e)(8)(ii)(A)(1)

and (e)(8)(ii)(A)(2) of this section.

(iii) Beginning on October 6, 1991, the owner and operator of the

Replogle Globes, Inc. plant in Broadview, Illinois shall keep the

following records for each month. All records shall be retained at

Replogle Globes, Inc. for three (3) years and shall be made available

to the Administrator on request.

(A) the name and identification number of each coating as applied

on any wood coating line.

(B) The weight of VOM per volume (determined in accordance with the

procedures in paragraph (a)(4)(i) of this section) and the volume of

each coating (minus water and any compounds which are specifically

exempted from the definition of VOM) as applied each month on any wood

coating line.

* * * * *

(h) * * *

(6) The control and recordkeeping and reporting requirements, as

well as the test methods in this paragraph, apply to the rotogravure

and flexographic presses at General Packaging Products, Inc.'s (GPP)

plant in Chicago, Illinois, instead of the requirements in 40 CFR

52.741(h)(1) through 40 CFR 52.741(h)(5).

(i) After July 1, 1992, no inks or other volatile organic material

(VOM) containing materials shall at any time be applied or used which

have a higher percent VOM by weight than the following:

(A) 8 percent VOM by weight for waterbased inks as applied on GPP's

presses.

(B) 82 percent VOM by weight for solvent based inks as applied on

GPP's presses.

(C) 100 percent VOM by weight for all other VOM containing

materials (besides inks) as used on GPP's presses.

(ii) After July 1, 1992, the weight of ink and other VOM containing

materials used shall not exceed the following:

(A) 200,000 pounds per year total for all waterbased inks, as

applied (including dilution material). The yearly weight of waterbased

inks used is to be calculated according to the procedure in paragraph

(h)(6)(iii) of this section.

(B) 100,008 pounds per year total for all solvent based inks, as

applied (including dilution material). The yearly weight of solvent

based inks used is to be calculated according to the procedure in

paragraph (h)(6)(iii) of this section.

(C) 100,000 pounds per year total (based upon the formulation of

the material as it is used on the presses) for all other VOM containing

materials (besides inks). The yearly weight of other VOM containing

materials is to be calculated according to the procedure in paragraph

(h)(6)(iii) of this section.

(iii) The yearly weight of ink/material used is to be calculated as

follows:

(A) Compute the weight of ink/material used each month by the 15th

of the following month.

(B) By the 15th of each month, add the monthly ink/material usage

for the 12 previous months (to obtain the yearly weight of ink/material

used).

(iv) Beginning on July 1, 1992, the owner and operator of GPP's

plant in Chicago, Illinois, shall keep the following records for each

month. All records shall be retained at GPP for 3 years and shall be

made available to the Administrator on request:

(A) The name and identification number of each waterbased ink, each

solvent based ink, and each other VOM containing material as applied or

used on any press.

(B) The pounds of waterbased ink as applied on all presses for each

month and the percent VOM by weight for each waterbased ink as applied

on any press for each month.

(C) The pounds of solvent based ink as applied on all presses for

each month and the percent VOM by weight for each solvent based ink as

applied on any press for each month.

(D) The pounds of other (non-ink) VOM containing material used on

all presses for each month and the percent VOM by weight for each (non-

ink) VOM containing material as used on any press for each month.

(v) Any record showing a violation of paragraph (h)(6)(i) or

(h)(6)(ii) of this section shall be reported by sending a copy of such

record to the Administrator within 30 days of the violation.

(vi) To determine compliance with paragraphs (h)(6)(i) and

(h)(6)(ii) of this section and to establish the records required under

paragraph (h)(6)(iv) of this section the percent VOM by weight of each

ink and other VOM containing material shall be determined by the

applicable test methods and procedures specified in paragraph (a)(4) of

this section.

* * * * *

(u) * * *

(6) The control requirements in this paragraph apply to the

adhesive globe coating operations at Replogle's Broadview facility in

Cook County, Illinois, instead of the control requirements in paragraph

(u)(3) of this section.

(i) After October 6, 1991, no coatings shall at any time be applied

which exceed the following emission limitations for the specified

coating.

(A) 7.0 lbs VOM per gallon of adhesive coating (minus water and any

compounds which are specifically exempted from the definition of VOM)

as applied to coat globes. Such coating consists of #7879446 Methylene

Chloride (RGI #01004100). The Administrator shall be notified at least

ten (10) days prior to the use of any replacement adhesive for coating

globes.

(B) [Reserved]

(ii) After October 6, 1991, the volume of coatings used shall not

exceed the following:

(A) 572 gallons per year total for all coatings specified in

paragraph (u)(6)(i)(A) of this section. The yearly volume of coatings

used are to be calculated as follows:

(1) Compute the volume of specified coating used each month by the

15th of the following month.

(2) By the 15th of each month, add the monthly coating use for the

12 previous months (to obtain the yearly volume of coatings used).

(B) [Reserved]

(iii) Beginning on October 6, 1991, the owner and operator of the

Replogle Globes, Inc. plant in Broadview, Illinois shall keep the

following records for each month. All records shall be retained at

Replogle Globes, Inc. for three (3) years and shall be made available

to the Administrator on request:

(A) The name and identification number of each coating as applied

on any adhesive globe coating line.

(B) The weight of VOM per volume and the volume of each coating

(minus water and any compounds which are specifically exempted from the

definition of VOM) as applied each month on any adhesive globe coating

line.

(7) The control requirements in this paragraph apply to the glass

candle container coating line(s) and silk screening machines at the

Candle Corporation of America (CCA), Chicago, Illinois facility,

instead of the control requirements in paragraph (u)(3) of this

section. [[Page 14902]]

(i) After June 1, 1992, no coatings or inks shall at any time be

applied, at any coating or ink applicator, which exceed the following

emission limitations for the specified coating or ink.

(A) 6.04 pounds (lbs) volatile organic material (VOM) per gallon of

clear lacquer/varnish (minus water and any compounds which are

specifically exempted from the definition of VOM) as applied to coat

glass candle containers. Such clear lacquer/varnish (multi-color) is

identified as LP3500. The Administrator must be notified at least 10

days prior to the use of any replacement clear lacquers/varnishes.

(B) 5.23 lbs VOM per gallon of translucent coating (minus water and

any compounds which are specifically exempted from the definition of

VOM) as applied to coat glass candle containers. Such translucent

coating (multi-color) is identified as LP3603. The Administrator must

be notified at least 10 days prior to the use of any replacement

translucent coatings.

(C) 5.84 lbs VOM per gallon of white lacquer (minus water and any

compounds which are specifically exempted from the definition of VOM)

as applied to coat glass candle containers. Such white lacquer is

identified as LP3507. The Administrator must be notified at least 10

days prior to the use of any replacement white lacquers.

(D) 3.40 lbs VOM per gallon of fast dry enamel silk screen printing

ink (minus water and any compounds which are specifically exempted from

the definition of VOM) as applied to print onto glass candle

containers.

(ii) After June 1, 1992, the volume of coating and ink used shall

not exceed the following:

(A) 2,164 gallons per month total for all coatings specified in

paragraph (u)(7)(i)(A) of this section.

(B) 369 gallons per month total for all coatings specified in

paragraph (u)(7)(i)(B) of this section.

(C) 49 gallons per month total for all coatings specified in

paragraph (u)(7)(i)(C) of this section.

(D) 50 gallons per month total for all inks specified in paragraph

(u)(7)(i)(D) of this Section.

(iii) Beginning on June 1, 1992, the owner and operator of CCA's

plant in Chicago, Illinois, shall keep the following records for each

month. All records shall be retained at CCA for 3 years and shall be

made available to the Administrator on request.

(A) The name and identification number of each coating and ink as

applied on any glass candle container coating line or silk screening

machine.

(B) The weight of VOM per volume and the volume of each coating and

ink (minus water and any compounds which are specifically exempted from

the definition of VOM) as applied each month on any glass candle

container coating line or silk screening machine.

(iv) After June 1, 1992, no more than 100 gallons per month of

cleaning solvent is allowed to be used on the glass candle container

coating line(s) at CCA. The only cleaning solvents allowed for use are

acetone (identified as LP3525) and methyl ethyl ketone (identified as

LP3520). Beginning on June 1, 1992, CCA shall keep monthly records of

the type and volume of all cleaning solvents used. All such records

shall be retained at CCA for 3 years and shall be made available to the

Administrator on request.

(v) After June 1, 1992, no more than 50 gallons per month of

cleaning solvent is allowed to be used on the glass candle container

silk screening machines at CCA. The only cleaning solvent allowed for

use is petroleum naphtha (identified as light aromatic naphtha with

7.28 lbs VOM per gallon, minus water and any compounds which are

specifically exempted from the definition of VOM). Beginning on June 1,

1992, CCA shall keep monthly records of the type and volume and the

weight of VOM per volume (minus water and any compounds which are

specifically exempted from the definition of VOM) of all cleaning

solvents used on the glass candle container silk screening machines.

All such records shall be retained at CCA for 3 years and shall be made

available to the Administrator on request.

* * * * *

(v) * * *

(6) The control requirements in this paragraph apply to the 7

blenders and 3 moguls of the adhesive coating solution formulation

(compounding) operations at the Minnesota Mining and Manufacturing

Corporation's (3M) Bedford Park facility in Cook County, Illinois,

instead of the control requirements in paragraph (v)(3) of this

section.

(i) After September 1, 1991, the following operating restrictions

shall apply to 3M's Bedford Park, Illinois, compounding operations.

(A) The combined operating hours for all blenders shall not exceed

8,400 hours per quarter (rolled on a monthly basis). The combined

quarterly operating hours of all blenders are to be calculated as

follows:

(1) By the 15th of each month, compute the combined monthly

operating hours of all blenders during the previous month.

(2) By the 15th of each month, add the monthly operating hours of

all blenders for the 3 previous months (to obtain the combined

quarterly operating hours of all blenders).

(B) The combined operating hours for all moguls shall not exceed

4,200 hours per quarter (rolled on a monthly basis). The quarterly

operating hours of all moguls are to be calculated as follows:

(1) By the 15th of each month, compute the combined monthly

operating hours of all moguls during the previous month.

(2) By the 15th of each month, add the monthly operating hours of

all moguls for the 3 previous months (to obtain the combined quarterly

operating hours of all moguls).

(ii) Beginning on September 1, 1991, the owner and operator of the

3M Bedford Park Plant in Bedford Park, Illinois, shall keep the

following records. These records shall be compiled on a monthly basis,

be retained at the 3M facility for a period of 3 years, and be made

available to the Administrator upon request.

(A) Separate monthly records for each of the 7 blenders identifying

each batch and the length of each batch as well as the total monthly

hours of operation for all blenders.

(B) Separate monthly records for each of the 3 moguls identifying

each batch and the length of each batch as well as the total monthly

hours of operation for all moguls.

* * * * *

(x) * * *

(6) The control requirements in this paragraph apply to the varnish

operations at the General Motors Corporation, Electro-Motive Division

Plant (GMC Electro-Motive), LaGrange, Illinois, instead of the control

requirements in paragraph (x)(3) of this section.

(i) After July 1, 1991, no coatings shall at any time be applied

which exceed the following emission limitations for the specified

coating.

(A) 8.0 lbs VOM per gallon of coating (minus water and any

compounds which are specifically exempted from the definition of VOM)

as applied at each coating applicator to coat Nomex rings. Such coating

consists of Monsanto Skybond 705 Polyamide Resin (EMD P/N 9088817) and

diluents. The Administrator must be notified at least 10 days prior to

the use of any replacement coating(s) and/or diluents for coating Nomex

rings.

(B) 6.8 lbs VOM per gallon of coating (minus water and any

compounds which are specifically exempted from the definition of VOM)

as applied at [[Page 14903]] each coating applicator for any coatings

not specified in paragraph (x)(6)(i)(A) of this section.

(ii) After July 1, 1991, the volume of coatings used shall not

exceed the following:

(A) 600 gallons per year total for all coatings specified in

paragraph (x)(6)(i)(A) of this section. The yearly volume of coatings

used are to be calculated as follows:

(1) Compute the volume of specified coating used each month by the

15th of the following month.

(2) By the 15th of each month, add the monthly coating use for the

12 previous months (to obtain the yearly volume of coatings used).

(B) 28,500 gallons per year total for all coatings other than those

specified in paragraph (x)(6)(i)(A) of this section. The yearly volume

of coatings used are to be calculated as specified in paragraphs

(x)(6)(ii)(A)(1) and (x)(6)(ii)(A)(2) of this section.

(iii) Beginning on July 1, 1991, the owner and operator of the

General Motors Corporation Electro-Motive Division Plant in LaGrange,

Illinois shall keep the following records for each month. All records

shall be retained at General Motors for 3 years and shall be made

available to the Administrator on request.

(A) The name and identification number of each coating as applied

on any coating line within the varnish operation.

(B) The weight of VOM per volume and the volume of each coating

(minus water and any compounds which are specifically exempted from the

definition of VOM) as applied each month on any coating line within the

varnish operation.

* * * * *

(8) The control and recordkeeping requirements in this paragraph

apply to the silk screen presses and associated ovens, cleaning

operations and laminators at Parisian's Novelty Company (Parisian),

Chicago, Illinois, facility, instead of the control requirements in

paragraphs (x)(8) (u)(3) and (x)(3) of this section and the

recordkeeping requirements in paragraph (x)(8)(y) of this section.

(i) After March 1, 1993, no coatings or inks shall at any time be

applied, at any coating or ink applicator, which exceed the following

emission limitations for the specified coating or ink.

(A) 6.65 pounds (lbs) volatile organic material (VOM) per gallon of

ink (minus water and any compounds which are specifically exempted from

the definition of VOM) as applied on Parisian's silk screen presses.

(B) 6.4 lbs VOM per gallon of adhesive coating (minus water and any

compounds which are specifically exempted from the definition of VOM)

as applied on Parisian's laminators. Such adhesive is identified as MIX

#963.

(ii) After March 1, 1993, the volume of coating and ink used shall

not exceed the following:

(A) 2,556 gallons per year total for all inks. The yearly volume of

inks used is to be calculated as follows:

(1) Compute the volume of ink used each month by the 15th of the

following month.

(2) By the 15th of each month, add the monthly ink usage for the 12

previous months (to obtain the yearly volume of ink used).

(B) 780 gallons per year total for all coatings specified in

paragraph (x)(8)(i)(B) of this section. The yearly volume of coatings

used are to be calculated as specified in paragraphs (x)(8)(ii)(A)(1)

and (x)(8)(ii)(A)(2) of this section.

(iii) Beginning on March 1, 1993, the owner and operator of

Parisian's plant in Chicago, Illinois, shall keep the following records

for each month. All records shall be retained at Parisian for 3 years

and shall be made available to the Administrator on request.

(A) The name and identification number of each coating as applied

on any laminator.

(B) The weight of VOM per volume and the volume of each coating

(minus water and any compounds which are specifically exempted from the

definition of VOM) as applied each month on any laminator.

(C) The weight of VOM per volume and the volume of each type of ink

(minus water and any compounds which are specifically exempted from the

definition of VOM) as applied each month on any screen press.

(iv) After March 1, 1993, no more than 84 gallons per year of

denatured alcohol may be used for cleaning labels at Parisian. The

yearly volume of denatured alcohol used is to be calculated as

specified in paragraphs (x)(8)(ii)(A)(1) and (x)(8)(ii)(A)(2) of this

section. Beginning on March 1, 1993, Parisian shall keep monthly

records of the type, volume, and VOM content of all solvents used for

label cleaning. These records shall be retained at Parisian for 3 years

and shall be made available to the Administrator on request.

(v) After March 1, 1993, no more than 7,932 gallons per year of

screen wash #956 may be used on Parisian's screen cleaner. The yearly

volume of screen wash #956 used is to be calculated as specified in

paragraphs (x)(8)(ii)(A)(1) and (x)(8)(ii)(A)(2) of this section.

Beginning on March 1, 1993, Parisian shall keep monthly records of the

type, volume, and VOM content of all cleaning compounds used on

Parisian's screen cleaner. These records shall be retained at Parisian

for 3 years and shall be made available to the Administrator on

request.

(vi) After March 1, 1993, only those cleaners specifically

identified in paragraphs (x)(8)(iv) and (x)(8)(v) of this section may

be used at Parisian.

(9) The control requirements in this paragraph apply to the process

sources listed in paragraph (x)(9)(i)(A) of this section at the Nalco

Chemical Company facility in Bedford Park, Illinois, instead of the

control requirements in paragraph (x)(3) of this section.

(i) Production and Operation Restrictions.

(A) On and after October 1, 1992, the maximum volatile organic

compound (VOC) emissions per batch, the 12-month rolling average number

of batches per year, and the peak limit of batches per month shall not

exceed the following limits:

--------------------------------------------------------------------------------------------------------------------------------------------------------

Maximum VOC

Source emissions, lb/batch 12-mo. rolling average limit batch/yr Peak batch limit, batch/month

--------------------------------------------------------------------------------------------------------------------------------------------------------

(1) System 1 0.16................ 280....................................................... 33.

charge.

System 1 purge 1.35................ .......................................................... ..................................................

(2) 24-T-156, 157. 2.60................ 300....................................................... 33.

(3) 28-T-217, 234. 0.23................ 402....................................................... 45.

(4) 28-T-214-216.. 5.70................ 603....................................................... 65.

(5) 20-R-182, 185. 0.02................ 72........................................................ 8.

(6) 20-R-130...... 0.07................ 340....................................................... 38.

(7) 20-R-155...... 0.21................ 254....................................................... 29.

[[Page 14904]]

(8) 20-WT-174..... 0.21................ 254....................................................... 29.

(9) 12-T-97-99.... 4.6E-4 lb/hr........ 8,760 hr/yr............................................... 744 hr/mo.

(10) 12-T-95...... 4.0E-6 lb/hr........ 8,760 hr/yr............................................... 744 hr/mo.

(11) 12-T-96...... 7.7E-5 lb/hr........ 8,760 hr/yr............................................... 744 hr/mo.

(12) 12-T-67, 73.. 0.003 lb/hr......... 8,760 hr/yr............................................... 744 hr/mo.

(13) 20-T-121-122. 0.85................ 312....................................................... 34.

(14) 20-T-123-125. 5.4................. 616....................................................... 68.

(15) 20-T-140, 142 8.0................. 600....................................................... 65.

(16) 20-T-159..... 0.31................ 416....................................................... 46.

(17) 20-R-193, 200 9.8................. 540....................................................... 59.

(18) 32-R-300..... 0.18................ 365....................................................... 41.

(19) 32-T-302..... 0.21................ 365....................................................... 41.

(20) 32-T-304..... 0.21................ 730....................................................... 81.

(21) 32-T-314..... 0.23................ 365....................................................... 41.

(22) 32-T-322..... 0.21................ 365....................................................... 41.

(23) 32-T-328..... 0.23................ 365....................................................... 41.

(24) 10-T-61...... 0.001............... 365--containing organic................................... 31--containing organic.

(25) 24-T-441, 166 0.12................ 730....................................................... 81.

(26) 25-T-284, 0.28................ 730....................................................... 81.

440, 443-444.

(27) 25-T-170..... 4E-6................ 104....................................................... 12.

(28) Tank truck 0.12 lb/truck....... 1,600 trucks/yr........................................... 134 trucks/mo.

loading.

(29) System 2..... 0.36................ 280....................................................... 33.

(30) System 4..... 2.88................ 280....................................................... 33.

(31) 25-R-164..... 0.10................ 365....................................................... 41.

(32) 25-R-205..... 0.14................ 365....................................................... 41.

(33) Drum station. 3.51................ 1,005..................................................... 110.

(34) V-4SAC....... 1.56................ 254....................................................... 29.

(35) 20-CT-155.... 13.90............... 254....................................................... 29.

(36) 12-SE-100.... 1.10 lb/hr.......... 8,760 hr/yr............................................... 744 hr/mo.

(37) Drum exhaust 1.00................ 365--involving use of organic material.................... 31--involving use of organic material.

hood A.

(38) 24-T-230..... 0.98................ 730....................................................... 81.

(39) 8-CT-1....... 0.002 lb/hr......... 8,760 hr/yr............................................... 744 hr/mo.

(40) 9-CT-1....... 0.002 lb/hr......... 8,760 hr/yr............................................... 744 hr/mo.

(41) 10-CT-1...... 0.005 lb/hr......... 8,760 hr/yr............................................... 744 hr/mo.

(42) 22-CT-1...... 0.003 lb/hr......... 8,760 hr/yr............................................... 744 hr/mo.

(43) 25-CT-1...... 0.005 lb/hr......... 8,760 hr/yr............................................... 744 hr/mo.

(44) 25-CT-2...... 0.002 lb/hr......... 8,760 hr/yr............................................... 744 hr/mo.

(45) 29-CT-1...... 0.002 lb/hr......... 8,760 hr/yr............................................... 744 hr/mo.

(46) 32-CT-1...... 0.005 lb/hr......... 8,760 hr/yr............................................... 744 hr/mo.

(47) 36-CT-1...... 0.002 lb/hr......... 8,760 hr/yr............................................... 744 hr/mo.

(48) 32-T-325..... 0a.................. 365....................................................... 41.

(49) 26-R-195..... 0.1a................ 365....................................................... 41.

(50) Continuous 0.1 lb/hra.......... 2,000 hr/yr............................................... ..................................................

polymer-blending.

(51) Portafeed 0.84 lb/hrb......... 4,160 hr/yr............................................... 744 hr/mo.

washer booth 1.

(52) Portafeed 0.84 lb/hrb......... 8,736 hr/yr............................................... 744 hr/mo.

washer booth 2.

(53) 32-T-392..... 4.4E-7.............. 104....................................................... 12.

--------------------------------------------------------------------------------------------------------------------------------------------------------

aAssumed value.

bBased on monitoring data.

(B) The following equation shall be used to calculate maximum VOC

emissions per batch for the process sources listed in paragraphs

(x)(9)(i)(A)(1) (charge only and (2) through (28) and (53) of this

section:

Where:

ER = VOC emission rate;

Qo = Quantity of organic per batch or charge rate;

[GRAPHIC][TIFF OMITTED]TR21MR95.000

Mv = Molecular weight of the volatile component;

P = Partial pressure of the volatile component for mixtures of liquid

made up with more than one chemical; or vapor pressure for pure liquids

made up of only one organic chemical; and

Constant1 = (7.45 gal/ft3)x(385 ft3/mole)x(760 mmHg).

(C) The following equation shall be used to calculate the VOC

emissions per batch from the process sources listed in paragraph

(x)(9)(i)(A)(1) of this section [[Page 14905]] (purge only) and (29)

through (32) of this section:

[GRAPHIC][TIFF OMITTED]TR21MR95.001

Where:

PR=Nitrogen purge rate; and

Constant2 = (385 ft3/mole)x(760 mmHg).

(D) The following equation shall be used to calculate the VOC emissions

per batch from the drum station listed at paragraph (x)(9)(i)(A)(33) of

this section:

ER(1b/batch) = (0.40 x [ER28-T-217-218])+(0.60 x [ER28-T-214-

216])

(E) The following equation shall be used to calculate the VOC

emissions per batch from the V-4SAC listed at paragraph

(x)(9)(i)(A)(34) of this section:

[GRAPHIC][TIFF OMITTED]TR21MR95.002

Where:

FR1mmHg = Maximum air flow rate to maintain 1 mmHg;

Ma = Molecular weight of air; and

Pv2 = Vapor pressure of organic at 65 deg.F and 760 mmHg.

(F) The following equation shall be used to calculate the VOC

emissions per batch from 20-CT-155 listed at paragraph (x)(9)(i)(A)(35)

of this section:

[GRAPHIC][TIFF OMITTED]TR21MR95.003

Where:

ERtot = Total system emission rate calculated using the following

equation:

[GRAPHIC][TIFF OMITTED]TR21MR95.004

Where:

Pv1 = Vapor pressure of organic at 200 deg.F and 350 mmHg.

(G) The following equation shall be used to calculate the VOC

emissions per hour from 12-SE-100 listed at paragraph (x)(9)(i)(A)(36)

of this section:

ER(lb/hr) = Evap (gm/cm2sec) x area (cm2) x 3600 sec/hr

Where:

Evap = Evaporation rate from a surface 8.93 cm x 8.9 cm (lb/

[cm2] [sec]) calculated using the following equation:

Evap = 10-7 Mv0.71 x [0.034 (Pe -

Pd)1.25 + 156 (Pe - Pd)]

Where:

Pe = Partial pressure of the component from the spilled liquid;

Pd = Partial pressure of the component in the incident air stream,

assumed to be 0 mmhg; and

Area = Surface area of the liquid.

(H) The following equation shall be used to calculate the VOC

emissions per batch from the drum exhaust hood A listed at paragraph

(x)(9)(i)(A)(37) of this section:

[GRAPHIC][TIFF OMITTED]TR21MR95.005

Where:

FR = Air flow rate.

(I) The following equation shall be used to calculate the VOC emissions

per batch from 24-T-230 listed at paragraph (x)(9)(i)(A)(38) of this

section:

[GRAPHIC][TIFF OMITTED]TR21MR95.006

[[Page 14906]]

Where:

VH = Head space volume at heated temperature 135 deg.F;

VA = Head space volume at ambient temperature 68 deg.F;

PP135 deg.F = Partial pressure of volatile component at 135 deg.F.

Constant3 = (434 ft3/mole)(7.45 gal/ft3)x(760 mmHg)

(J) The following equations shall be used to calculate the VOC

emissions per batch from the process sources listed in paragraph

(x)(9)(i) (39) through (47) of this section:

[GRAPHIC][TIFF OMITTED]TR21MR95.007

Where:

VR = Refill volume;

t = Time between refills;

org = Fraction of organic component in product;

CB = Concentration of chemical B fed 3 times/week;

VT = Tower volume;

dB = Density of chemical B;

CC = Concentration of chemical C fed continuously;

Evap = Evaporation rate; and

dc = Density of chemical C.

(K) The number of batches for each process source shall be

calculated as follows:

(1) Compute the monthly number of batches for each process source

by the 15th day of the following month.

(2) By the 15th day of each month, add the monthly number of

batches for each process source for the 12 previous months to obtain

the total number of batches per year.

(ii) Recordingkeeping.

(A) On and after October 1, 1992, the owner and operator of the

Nalco Chemical Company facility in Bedford Park, Illinois, shall keep

the following records for all process sources listed in paragraphs

(x)(9)(i)(A) (1) through (53) of this section. These records shall be

maintained for the units specified in paragraphs (x)(9)(i) (A) through

(K) of this section, be compiled on a monthly basis, be retained at the

facility for a period of 3 years, and be made available to the

Administrator upon request.

(B) [Reserved]

(1) Calculations of the pounds per batch or pounds per hour (as

appropriate) for each batch for each process source. This includes the

information necessary for each calculation.

(2) The monthly number of batches for each process source.

(3) The total number of batches per year for the 12 previous months

for each process source.

(10) The control requirements in this paragraph apply to the

storage tanks listed in paragraph (x)(10)(i)(A) of this section at the

Nalco Chemical Company facility in Bedford Park, Illinois, instead of

the control requirements in paragraph (x)(3) of this section.

(i) Production and Operation Restrictions.

(A) On and after October 1, 1992, the product of the molecular

weight of vapor in each storage tank (Mv), the true vapor pressure

at bulk liquid conditions for each tank (P), and the paint factor

(Fp); the storage tank maximum yearly throughput for each tank;

and the maximum monthly throughput for each tank shall not exceed the

following limits:

------------------------------------------------------------------------

MV x P x

Fp, (lb) Yearly Monthly

Tank No. (mmhg)/lb- throughput, throughput,

mole gal/yr gal/month

------------------------------------------------------------------------

(1) 24-T-147................. 45.4 56,250 4,688

(2) 24-T-150................. 227 266,450 22,204

(3) 24-T-151................. 227 266,450 22,204

(4) 24-T-158N................ 18.9 173,830 14,486

(5) 24-T-158C................ 18.0 110,190 9,183

(6) 24-T-158S................ 1.17 52,010 4,334

(7) 24-T-160................. 226.8 266,450 22,204

(8) 24-T-161................. 227 182,450 15,204

(9) 24-T-162................. 473 93,900 7,825

(10) 20-T-101................ 3.72 90,290 7,525

(11) 20-T-102................ 1.80 122,900 10,242

(12) 20-T-103................ 420 23,960 1,997

(13) 20-T-104................ 180 475,900 39,659

(14) 20-T-105................ 370 52,360 4,363

(15) 20-T-106................ 1,210 623,100 51,926

(16) 20-T-107................ 294 90,040 7,503

(17) 20-T-108................ 1,360 81,470 6,789

(18) 20-T-109................ 1,390 167,060 13,922

(19) 20-T-153................ 180 35,000 2,917

(20) 20-T-131a............... ............ .............. ...........

(21) 20-T-132a............... ............ .............. ...........

(22) 20-T-133a............... ............ .............. ...........

(23) 20-T-134a............... ............ .............. ...........

(24) 20-T-135a............... ............ .............. ...........

(25) 20-T-136................ 29.5 307,710 26,580

(26) 20-T-137a...............

[[Page 14907]]

(27) 20-T-138................ 29.5 307,710 26,580

(28) 32-T-305................ 288 785,550 65,462

(29) 32-T-306................ 66.5 165,350 13,779

(30) 32-T-307................ 66.5 294,750 24,563

(31) 32-T-308................ 66.5 128,470 10,706

(32) 32-T-310................ 66.5 77,290 6,441

(33) 32-T-311................ 66.5 182,130 15,177

(34) 32-T-319................ 50.0 688,950 57,413

(35) 32-T-320................ 50.0 688,950 57,413

(36) 32-T-326................ 70.0 248,440 20,703

(37) 32-T-331................ 70.0 489,540 40,795

(38) 32-T-332................ 70.0 70,380 5,865

(39) 32-T-333................ 70.0 270,850 22,571

(40) 32-T-334................ 70.0 210,610 18,267

(41) 32-T-335................ 70.0 418,200 34,850

(42) 32-T-336................ 70.0 632,460 52,706

(43) 32-T-337................ 798 53,850 4,488

(44) 17-T-206................ 27,000 300,760 25,063

(45) 17-T-208................ 27,000 300,760 25,063

(46) 17-T-207................ 2.48 180,180 15,016

(47) 17-T-209................ 2.48 180,180 15,016

(48) 24-T-515................ 331 216,860 18,072

(49) 25-T-282................ 1.42 1,920,410 160,034

(50) 25-T-283................ 1.42 1,920,410 160,034

(51) 24-T-442................ 18.0 90,990 7,583

(52) 17-T-210................ 47.9 582,990 48,583

(53) 17-T-211................ 47.9 582,990 48,583

(54) 17-T-212................ 508 728,420 60,702

(55) 17-T-213................ 508 728,420 60,702

(56) 17-T-401................ 50.0 131,970 10,998

(57) 17-T-402................ 15.0 120,160 10,014

(58) 17-T-403................ 6.20 127,770 10,648

(59) 17-T-404................ 26.5 1,601,510 133,460

(60) 17-T-405................ 50.0 113,830 9,486

(61) 17-T-406................ 40.0 231,030 19,253

(62) 17-T-407................ 206 135,180 11,265

(63) 17-T-409................ 395 327,410 27,285

(64) 17-T-410................ 395 129,290 10,774

(65) 17-T-411................ 50.0 213,870 17,843

(66) 17-T-412................ 50.0 277,840 23,153

(67) 17-T-414................ 50.0 72,920 6,077

(68) 17-T-415................ 50.0 56,140 4,678

(69) 17-T-416................ 395 393,550 32,796

(70) 17-T-417................ 23.4 233,780 19,482

(71) 17-T-418................ 115 873,270 72,773

(72) 17-T-419................ 119 278,460 23,205

(73) 17-T-420................ 112 730,780 60,898

(74) 17-T-421................ 25.2 300,010 25,001

(75) 17-T-422................ 115 873,270 72,773

(76) 17-T-423................ 23.4 215,060 17,922

(77) 17-T-424................ 23.4 209,610 17,468

(78) 26-T-218................ 50.0 64,890 5,408

(79) 26-T-219................ 1.50 197,900 16,492

(80) 26-T-220................ 2,460 160,020 13,336

(81) 26-T-221................ 50.0 74,820 6,235

(82) 26-T-222................ 80.0 66,590 5,550

(83) 26-T-224................ 4.80 225,290 18,774

(84) 26-T-225................ 50.0 36,610 3,051

(85) 26-T-226................ 294 47,390 3,949

(86) 26-T-227................ 50.0 63,040 5,253

(87) 26-T-228................ 500 136,150 11,346

(88) 26-T-229................ 50.0 112,970 9,414

(89) 26-T-231................ 23.4 319,610 26,634

(90) 26-T-232................ 117 564,280 47,024

(91) 26-T-233................ 23.4 539,700 44,975

(92) 27-T-245................ 21.6 361,970 30,165

(93) 27-T-246................ 348 141,820 11,818

(94) 27-T-247................ 23.4 71,670 5,972

(95) 27-T-248................ 198 96,010 8,001

(96) 27-T-249................ 927 51,240 4,270

(97) 27-T-250................ 110 433,030 36,086

(98) 27-T-251................ 396 45,440 3,787

[[Page 14908]]

(99) 27-T-252................ 21.6 171,370 14,281

(100) 27-T-253............... 348 237,900 19,825

(101) 26-T-192............... 10.0 117,950 9,829

(102) 27-T-278............... 0.62 74,910 6,243

(103) 27-T-279............... 0.18 583,760 48,647

(104) 27-T-285............... 21.6 459,530 38,294

(105) 27-T-286............... 21.6 459,530 38,294

(106) 25-T-201............... 19.8 143,550 11,963

(107) 32-T-388............... 0.07 499,340 41,612

(108) 32-T-389............... 0.07 499,340 41,612

(109) 32-T-390............... 288 808,310 583,340

(110) 32-T-391............... 1.42 800,00 583,340

------------------------------------------------------------------------

aTank not in use.

(B) The throughput shall be calculated as follows:

(1) Compute the monthly throughput for each tank by the 15th day of

the following month.

(2) By the 15th day of each month, add the monthly throughputs for

the 12 previous months to obtain the yearly throughput.

(ii) Recordkeeping. (A) On and after October 1, 1992, the owner and

operator of the Nalco Chemical Company facility in Bedford Park,

Illinois, shall keep the following records for all storage tanks. These

records shall be compiled on a monthly basis, be retained at the

facility for a period of 3 years, and be made available to the

Administrator upon request.

(1) The molecular weight of vapor in each storage tank (Mv),

the true vapor pressure at bulk liquid conditions for each tank (P),

the paint factor (Fp), and their product. Fp shall be

determined from Table 4.3-1 of ``Compilation of Air Pollutant Emission

Factors, Volume I: Stationary Point and Area Sources,'' AP-42,

September 1985.

(2) The monthly throughput.

(3) The total throughput per year for the 12 previous months.

(B) [Reserved].

(iii) Test Methods. (A) The true vapor pressure at bulk liquid

temperature shall be determined by using the procedures specified in

paragraph (a)(8) of this section.

(B) The molecular weight of vapor in the storage tank shall be

determined by using Table 4.3-2 ``Compilation of Air Pollutant Emission

Factors, Volume I: Stationary Point and Area Sources,'' AP-42,

September 1985, or by analysis of vapor samples. Where mixtures of

organic liquids are stored in a tank, Mv shall be estimated from

the liquid composition using the following equation:

[GRAPHIC][TIFF OMITTED]TR21MR95.008

Where:

Ma=Molecular weight of pure component a;

Pa=Vapor pressure of pure component a;

Xa=Mole fraction of pure component a in the liquid;

Mb=Molecular weight of pure component b;

Pb=Vapor pressure of pure component b;

Xb=Mole fraction of pure component b in the liquid; and

Pt=PaX2+PbXb.

(11) The control requirements in this paragraph apply to the

fugitive emission sources listed in paragraph (x)(11)(i)(A) of this

section at the Nalco Chemical Company facility in Bedfore Park,

Illinois, instead of the control requirements in paragraph (x)(3) of

this section.

(i) Production and Operation Restrictions.

(A) On and after October 1, 1992, all components (e.g., pumps,

valves, flanges, pressure relief valves (PRV's), and open end lines) at

the specified locations (e.g., Building 32--Tube Reactor System, etc.),

and in the specified type of service (e.g., heavy liquid stratified,

light liquid stratified, etc.) shall be limited by the maximum monthly

hours in the following table:

(ii) Recordkeeping.

(A) On and after October 1, 1992, the owner and operator of the

Nalco Chemical Company facility in Bedford Park, Illinois, shall keep

the following records for all fugitive emission sources. These records

shall be compiled on a monthly basis, be retained at the facility for a

period of 3 years, and be made available to the Administrator upon

request.

(1) The total number of hours of organic service for each component

at each location specified in paragraphs (x)(11)(i)(A) (1) through (10)

of this section.

(2) The vapor pressure of each organic compound in each component

at each location specified in paragraphs (x)(11)(i)(A) (1) through (10)

of this section.

(B) [Reserved]

(12) The control and recordkeeping and reporting requirements, as

well as the test methods in this paragraph, apply to the gravure and

screen press operations at the Meyercord Corporation (Meyercord) in

Carol Stream, Illinois, instead of the requirements in paragraphs

(x)(1) through (x)(5) of this section.

(i) After July 1, 1991, no materials which contain volatile organic

material (VOM), including coatings, inks, and cleaning material, may be

used at any gravure or screen press unless the total VOM emissions

remain below 100 tons of VOM for every consecutive 365-day period, or

fraction thereof, starting on July 1, 1991. A new 365-day period starts

on each day. The VOM emissions, which are to be calculated on a daily

basis, are to be added to the VOM emissions for the prior 364 days (but

not including any day prior to July 1, 1991). VOM emissions are based

upon the VOM content of the material and the volume of material used.

The effect of add-on control equipment is not considered in calculating

VOM emissions; that is, the VOM emissions are to be determined as if

the press(es) [[Page 14909]] do(es) not have add-on control equipment.

The applicable test methods and procedures specified in paragraph

(a)(4) of this section are to be used in determining daily VOM

emissions.

(ii) The VOM content of each coating, ink, and cleaning solution

shall be determined by the applicable test methods and procedures

specified in paragraph (a)(4) of this section to establish the records

required under paragraph (x)(12)(ii) of this section. Beginning on July

1, 1991, the owner or operator of the subject presses shall collect and

record all of the following information each day and maintain the

information at the facility for 3 years:

(A) The name and identification number of each coating, ink, and

cleaning solution as applied on any press.

(B) The pounds (lbs) of VOM per gallon of each coating, ink, and

cleaning solution (minus water and any compounds which are specifically

exempted from the definition of VOM) as applied on any press.

(C) The total gallons of each coating, ink, and cleaning solution

(minus water and any compounds which are specifically exempted from the

definition of VOM) used per day.

(D) The total lbs of VOM contained in the volume of each coating,

ink, and cleaning solution used per day on any press. The lbs of VOM

per day is to be calculated by multiplying the lbs of VOM per gallon

(minus water and any compounds which are specifically exempted from the

definition of VOM) times the gallons (minus water and any compounds

which are specifically exempted from the definition of VOM) used per

day.

(E) The total lbs of VOM per day from all coatings, inks, and

cleaning solutions used on all presses. The total lbs of VOM per day is

to be obtained by adding the lbs of VOM per day contained in all

coatings, inks, and cleaning solutions.

(F) Within 7 days after each 365-day period, the VOM emissions (as

calculated in paragraph (x)(12)(ii)(E)) of this section before add-on

control, from the 365-day period, are to be determined.

Starting on July 7, 1992, VOM emissions are to be determined for

the 365 days ending 7 days earlier. Each day concludes a new 365-day

period. However, no VOM emissions are to be included for any days prior

to July 1, 1991. For example, on July 17, 1991, the emissions from July

1, through July 10, 1991, are to be included, whereas on January 7,

1994, the emissions from January 1, 1993, through December 31, 1993,

are to be included.

(13) The control and recordkeeping and reporting requirements, as

well as the test methods in this paragraph, apply to the sheet fed cold

set presses and web heatset presses at the Wallace Computer Services,

Inc. (Wallace) printing and binding plant in Hillside, Illinois,

instead of the requirements in 40 CFR 52.741(h) and 40 CFR 52.741(x)(1)

through 40 CFR 52.741(x)(5).

(i) After July 1, 1991, no inks shall at any time be applied, at

the presses indicated below, which exceed the pounds (lbs) volatile

organic material (VOM) per gallon of ink (minus water and any compounds

which are specifically exempted from the definition of VOM) limit

established for each press. After July 1, 1991, the yearly volume of

ink used at each press, in gallons of ink (minus water and any

compounds which are specifically exempted from the definition of VOM)

per year, shall not exceed the gallons per year limit established below

for each press. The yearly volume of ink used per press is to be

calculated according to the procedure in paragraph (x)(13)(iii) of this

section.

------------------------------------------------------------------------

Lbs VOM/

Press gallon Gallons/

ink year ink

------------------------------------------------------------------------

14.................................................. 1.68 276

16.................................................. 1.68 1896

22.................................................. 3.01 2712

23.................................................. 3.01 13140

25.................................................. 3.01 12720

26.................................................. 3.01 4764

------------------------------------------------------------------------

(ii) After July 1, 1991, no materials (other than those inks

subject to the limits in paragraph (x)(13)(i)) of this section, shall

at any time be applied or used, at the presses indicated below, which

exceed the lbs VOM per gallon of material (minus water and any

compounds which are specifically exempted from the definition of VOM)

limit established for each press. After July 1, 1991, the yearly volume

of material (excluding ink and water) used at each press, in gallons of

material (minus water and any compounds which are specifically exempted

from the definition of VOM) per year, shall not exceed the gallons per

year limit established for each press. The yearly volume of material

(excluding ink and water) used per press is to be calculated according

to the procedure in paragraph (x)(13)(iii) of this section.

------------------------------------------------------------------------

Lbs VOM/ Gallons/

Press gallon year

material material

------------------------------------------------------------------------

14................................................. 6.9 612

16................................................. 6.9 8,340

22................................................. 7.1 360

23................................................. 7.1 480

25................................................. 7.1 516

26................................................. 7.1 1,848

------------------------------------------------------------------------

(iii) The yearly volume of ink/material used is to be calculated as

follows:

(A) Compute the volume of ink/material used each month per press by

the 15th of the following month.

(B) By the 15th of each month, add the monthly ink/material usage

per press for the 12 previous months (to obtain the yearly volume of

ink used).

(iv) Beginning on July 1, 1991, the owner and operator of Wallace's

plant in Hillside, Illinois, shall keep the following records for each

press for each month. All records shall be retained by Wallace for 3

years and shall be made available to the Administrator on request:

(A) The name and identification number of each ink, fountain

solution, fountain solution additive, cleaning solvent, and other VOM

containing material as applied or used.

(B) The weight of VOM per volume of each ink, fountain solution,

fountain solution additive, cleaning solvent, and each other VOM

containing material (minus water and any compounds which are

specifically exempted from the definition of VOM) as applied or used

each month.

(C) The volume of ink (minus water and any compounds which are

specifically exempted from the definition of VOM) as applied each

month.

(D) The total volume of miscellaneous VOM containing materials

(minus water and any compounds which are specifically exempted from the

definition of VOM), other than inks, that are used each month.

(v) Any record showing a violation of paragraph (x)(13)(i) or

(x)(13)(ii) of this section shall be reported by sending a copy of such

record to the Administrator within 30 days of the violation.

(vi) To determine compliance with paragraphs (x)(13)(i) and

(x)(13)(ii) of this section and to establish the records required under

paragraph (x)(13)(iv) of this section the VOM content of each ink and

miscellaneous VOM containing material shall be determined by the

applicable test methods and procedures [[Page 14910]] specified in

paragraph (a)(4) of this section.

[FR Doc. 95-6003 Filed 3-20-95; 8:45 am]

BILLING CODE 6560-50-M

This is a copy of a public record, reproduced as it was published. It is not legal advice, and it may not be the version a court would rely on. Check the official source before you cite it.

A word about cookies

We need a few to keep you signed in and the library working. The rest help us see which pages people use and where they get stuck. They stay off unless you say yes.