Energy Conservation Program for Consumer Products: Test Procedures for Water Heaters; Kitchen Ranges, Ovens, and Microwave Ovens; and Clothes Washers; and Reporting Requirements for Clothes Washers, Clothes Dryers, and Dishwashers

Federal RegisterMar 23, 1995

Ask Donna

What actually matters in this document.

Text

SUMMARY: The Energy Policy and Conservation Act, as amended, requires

the Department of Energy (DOE or the Department) to administer an

energy conservation program for certain major household appliances and

commercial equipment. Among other program elements, the Act requires

that standard methods of testing be prescribed for each covered

product. The purposes of this Proposed Rulemaking are to: propose

amendments to clarify the water heater; kitchen range, oven, and

microwave; and clothes washer test procedures, announce the

Department's intentions to incorporate by reference test procedures

adopted by the International Electrotechnical Commission (IEC), and

request data, comments, and information regarding their applicability

and workability. Today's amendments of the test procedures are not

expected to alter the minimum energy conservation standards currently

in effect, or those being proposed in the Eight Products Notice of

Proposed Rulemaking, published March 4, 1994 (59 FR 10464).

DATES: Written comments in response to this notice must be received by

August 31, 1995.

Oral views, data, and arguments may be presented at the public

hearing to be held in Washington, DC, beginning at 9:30 a.m. on July

12, 1995. Requests to speak at the hearing must be received by the

Department no later than 4 p.m., June 28, 1995. Ten (10) copies of

statements to be given at the public hearing must be received by the

Department no later than 4 p.m., July 5, 1995.

ADDRESSES: Written comments, and requests to speak at the public

hearing are to be submitted to: U.S. Department of Energy, Office of

Energy Efficiency and Renewable Energy, Hearings and Dockets, Test

Procedures for Water Heaters; Kitchen Ranges, Ovens, and Microwave

Ovens; and Clothes Washers; and Reporting Requirements for Clothes

Washers, Clothes Dryers, and Dishwashers,'' Docket No. EE-RM-94-230,

Forrestal Building, 1000 Independence Avenue, SW., Washington, DC

20585.

The hearing will be held at the U.S. Department of Energy,

Forrestal Building, Room 1E-245, 1000 Independence Avenue, SW.,

Washington, DC.

Requests may be hand delivered between the hours of 8 a.m. and 4

p.m., Monday through Friday, except Federal holidays. Requests should

be labeled, ``Test Procedures for Water Heaters; Kitchen Ranges, Ovens,

and Microwave Ovens; and Clothes Washers; and Reporting Requirements

for Clothes Washers, Clothes Dryers, and Dishwashers,'' (Docket No. EE-

RM-94-230), both on the document and on the envelope.

Copies of the transcript of the public hearing and public comments

received may be read and/or photocopied at the Department of Energy

Freedom of Information Reading Room, U.S. Department of Energy,

Forrestal Building, Room 1E-190, 1000 Independence Avenue, SW.,

Washington, DC 20585, (202) 586-6020 between the hours of 9 a.m. and 4

p.m., Monday through Friday, except Federal holidays.

The Department will incorporate by reference test standards from

the International Electrotechnical Commission upon publication of this

rule as final. These standards are listed below:

International Electrotechnical Commission Publication 705, and

Amendment 2-1993, ``Methods for Measuring the Performance of

Microwave Ovens for Household and Similar Purposes,'' Section 4,

Paragraph 12 ``Microwave Power Output Measurement,'' Paragraph 13

``Electrical Power Output Measurement,'' and Paragraph 14

``Efficiency.''

Copies of these standards may be viewed at the Department of Energy

Freedom of Information Reading Room at the address stated above. Copies

of the International Electrotechnical Commission Publication can be

obtained from the American National Standards Institute, 11 West 42nd

Street, New York, New York 10036, (212) 642-4936.

For more information concerning public participation in this

rulemaking proceeding, see Section XI, ``Public Comment Procedures,''

of the SUPPLEMENTARY INFORMATION section.

FOR FURTHER INFORMATION CONTACT:

William W. Hui--Water Heaters (202) 586-9145

Ingrid M. Watson--Ranges, Ovens and Microwaves (202) 586-8119

Marc LaFrance--Clothes Washers and Dryers, and Dishwashers (202) 586-

8423

U.S. Department of Energy, Energy Efficiency and Renewable Energy,Mail

Station EE-431, Forrestal Building, 1000 Independence Avenue, SW.,

Washington, DC. 20585

Eugene Margolis, Esq., U.S. Department of Energy, Office of General

Counsel, Mail Station GC-72, Forrestal Building, 1000 Independence

Avenue, SW., Washington, D.C. 20585, (202) 586-9507.

SUPPLEMENTARY INFORMATION:

I. Introduction

A. Authority

Part B of Title III of the Energy Policy and Conservation Act, Pub.

L. 94-163, as amended by the National Energy Conservation Policy Act,

Pub. L. 95-619, the National Appliance Energy Conservation Act of 1987,

Pub. L. 100-12, the National Appliance Energy Conservation Amendments

of 1988, Pub. L. 100-357, and the Energy Policy Act of 1992, Pub. L.

102-486, created the Energy Conservation Program for Consumer Products

other than Automobiles (Program).1 The products currently subject

to this Program (often referred to hereafter as ``covered products'')

include water heaters; kitchen ranges, ovens, and microwaves; and

clothes washers, the subjects of today's notice.

\1\Part B of Title III of Energy Policy and Conservation Act, as

amended, is referred to in this final rule as ``EPCA'' or the

``Act.'' Part B of Title III is codified at 42 U.S.C. 6291-6309.

---------------------------------------------------------------------------

Under the Act, the Program consists essentially of three parts:

Testing, labeling, and the Federal energy conservation standards. The

Department, in consultation with the National Institute of Standards

and Technology (formerly the National Bureau of Standards), is required

to amend or establish new test procedures as appropriate for each of

the covered products. EPCA, section 323. The purpose of the test

procedures is to produce test results which measure energy efficiency,

energy use, water use (in the case of showerheads, faucets, water

closets and urinals), or estimated annual operating cost of a covered

product during a representative average use cycle or period of use, and

must not be unduly burdensome to conduct. EPCA, section 323(b)(3). A

test [[Page 15331]] procedure is not required if DOE determines by rule

that one cannot be developed. EPCA, section 323(d)(1). One hundred and

eighty days after a test procedure for a product is adopted, no

manufacturer may make representations with respect to energy use,

energy efficiency or water use of such product, or the cost of energy

consumed by such product, except as reflected in tests conducted

according to the DOE procedure. EPCA, section 323(c)(2). Test

procedures appear at 10 CFR part 430, subpart B.

However, the 180-day period referred to in section 323(c)(2) may be

extended for a period of up to an additional 180 days if the Secretary

determines that the requirements of section 323(c)(2) would impose

undue burden. EPCA, section 323(c)(3).

Section 323(e) of the Act requires DOE to determine to what extent,

if any, a proposed test procedure would alter the measured energy

efficiency, measured energy use or measured water use of any covered

product as determined under the existing test procedure. If DOE

determines that an amended test procedure would alter the measured

efficiency or measured use of a covered product, DOE is required to

amend the applicable energy conservation standard accordingly. In

determining the amended energy conservation standard, DOE is required

to measure the energy efficiency or energy use of a representative

sample of covered products that minimally comply with the existing

standard. The average efficiency of these representative samples,

tested using the amended test procedure, constitutes the amended

standard. EPCA, section 323(e)(2).

B. Background

Today's notice proposes to modify the test procedures for water

heaters; kitchen ranges, ovens, and microwave ovens; and clothes

washers as follows:

(1) Water heaters.

(a) Revision of subpart B, appendix E.

1. Modify the test procedures to address electric and oil-fired

instantaneous water heaters.

2. Include testing of storage-type water heaters having rated

storage capacities less than 20 gallons (76 liters).

3. Revise the method used to calculate the first hour rating of

storage-type water heaters.

4. Amend the extant definition for heat pump water heater, and add

new definitions for heat pump water heater storage tank, add-on heat

pump water heater, integral heat pump water heater, and solar water

heater.

(2) Kitchen ranges, ovens, and microwaves.

(a) Revision of subpart B, section 430.22 to include test procedure

changes.

(b) Revision of subpart B, appendix I.

1. Revise the annual useful energy output to reflect changes in the

annual usage of ranges, ovens, cooktops, and microwave ovens.

2. Add definition for ``IEC 705.''

3. Eliminate the requirement to use a standard continuous flow

calorimeter.

4. Incorporate by reference the International Electrotechnical

Commission Publication 705 Amendment 2-1993, section 4, Paragraphs 12-

14.

5. Include the clock energy in the calculation of annual energy

consumption for microwave ovens.

6. Revise section 2.8 ``Test Beakers'' replace with new section 2.8

``Microwave Oven Test Load.''

7. Revise section 2.9.3.4 ``Microwave Oven and Test Load

Temperature,'' replace with new section 2.9.3.4 ``Test Load

Temperature.''

8. Eliminate section 4.3 ``Conventional Range,'' and section 4.5

``Microwave/Conventional Range.'' These two sections have been replaced

with a new section 4.3 ``Combined Components'' in this proposed rule.

(3) Clothes washers.

(a) Revision of subpart B, Sec. 430.22 to include test procedure

changes and to revise the number of representative average-use cycles

per year.

(b) Revision of subpart B, appendix J.

1. General test procedure clarification which includes the

following:

Add new definitions for the following terms:

thermostatically controlled valves, agitator, top-loader-vertical-axis

clothes washer, and top-loader-horizontal-axis clothes washer.

Delete the requirement to disconnect all lighting systems

which consume more than 10 watts during the clothes washer test cycle.

Introduce a new section, section 2.11 ``Agitation and Spin

Speed Settings.''

Delete reference to AHAM and AHAM procedures.

Clarify the procedure for capacity testing.

Clarify the requirements for ``maximum fill'' testing.

2. Incorporation of test procedure changes from approved Waivers to

address the following issues:

Add new definitions for the following terms: nonwater-

heating clothes washers and water-heating clothes washers.

Extend coverage for washers that operate at 120/208Y and

120/240 volts.

Extend testing and performance coverage to water-heating

clothes washers.

Extend coverage for clothes washers that have infinite/

variable temperature selection capability.

3. Addition of optional water consumption and extraction procedures

which include the following:

Add new definitions for the following terms: modified

energy factor, moisture removal energy and water consumption factor.

Add optional test procedures to determine the above

values.

(4) Addition to subpart F, Sec. 430.62, to add reporting

requirements for energy factors for clothes washers, clothes dryers,

and dishwashers.

In addition, metric units of measurements have been included in the

three test procedures (English values are given followed by their

appropriate International System of Units in parentheses).

II. Discussion

A. Water Heater Test Procedure

Today's proposed amendments to the water heater test procedure

include: Revisions to make the water heater test procedure applicable

to electric and oil-fired instantaneous water heaters; coverage for

testing storage-type water heaters with rated storage capacities less

than 20 gallons (76 liters); revision of the first hour rating for

storage-type water heaters; amendment to the extant definition for heat

pump water heater; and addition of new definitions for heat pump water

heater storage tank, add-on heat pump water heater, integral heat pump

water heater, and solar water heater.

The Department does not believe any of these changes would alter

the energy conservation standards for water heaters currently in place,

and requests comments on the impact of these changes, if any. In

addition, DOE requests comments on the adequateness of the test

procedure for heat pump water heaters regarding the use of backup

electric resistance element(s). To the Department's knowledge, most

heat pump water heaters are capable of meeting the current test draw

requirements, and therefore, the backup electric resistance element(s)

are often unnecessary, and are seldom activated. However, the current

test setup and parameters may not represent operating conditions

requiring backup electric resistance elements to activate. This is

dependent on a number of factors, i.e., temperature settings, draw

volume and rate, etc. Therefore, DOE is interested in receiving

comments on the test [[Page 15332]] procedure for heat pump water

heaters regarding the use of backup electric resistance element(s).

Concurrently, the Department is conducting a rulemaking,

independent of today's notice, to propose revised minimum energy

conservation standards for eight consumer products, including water

heaters. (59 FR 10464, March 4, 1994).

1. Electric and Oil-Fired Instantaneous Water Heaters

The current test procedure does not address testing of electric and

oil-fired instantaneous water heaters in that they are not defined in

the test procedure. The Department, therefore, proposes to include

definitions for these two types of instantaneous water heaters, and to

amend the existing language to include the testing of them. Definitions

for storage-type water heaters are also modified to differentiate these

types from the instantaneous-type water heaters. As a result, oil-fired

and electric instantaneous water heaters will be subject to the

applicable minimum energy conservation standards of 0.59-(0.0019 x

rated storage volume in gallons) for oil-fired water heaters and 0.93-

(0.00132 x rated storage volume in gallons) for electric water

heaters, respectively. For electric and oil fired instantaneous water

heaters, the rated storage volume may be zero. In today's proposed

notice, the Department requests comments and data regarding the

appropriateness of adding electric and oil-fired instantaneous water

heaters to the test procedure and subjecting them to the respective

energy conservation standards. See appendix E to subpart B of Title 10

CFR part 430, sections 1.8 and 5.2.

2. Storage-type Water Heaters Having Rated Storage Capacities Less Than

20 Gallons (76 liters)

In a letter to the Department, dated July 17, 1991, the Gas

Appliance Manufacturer Association (GAMA) stated that storage-type

water heaters having capacities less than 20 gallons (76 liters) are

covered by the National Appliance Energy Conservation Act of 1987. The

current test procedure does not cover storage-type water heaters having

rated storage capacities less than 20 gallons (76 liters) and,

therefore, those water heaters are not subject to the minimum

efficiency standards. In order to correct this, GAMA requested that the

test procedure be revised. DOE proposes to provide coverage for

storage-type water heaters of less than 20 gallons (76 liters).

With regard to conducting the 24-hour simulated use test on water

heaters having rated storage capacities less than 20 gallons (76

liters), the Department proposes to include the applicable draw

schedule accepted by the water heater industry. (See American National

Standards Institute/American Society of Heating, Refrigerating and Air-

Conditioning Engineers (ASHRAE) Standard 118.2-1993: Method of Testing

for Rated Residential Water Heaters.) The total volume withdrawn shall

be 24 gallons (91 liters) for units having rated storage capacities

greater than or equal to 10 gallons (38 liters), but less than 20

gallons (76 liters). The total volume withdrawn shall be 9 gallons (34

liters) for units having rated storage capacities less than 10 gallons

(38 liters). The draw rate shall be 1.00.25 gallons per

minute (3.80.95 liters per minute) for all units having

rated storage capacities less than 20 gallons (76 liters). The

Department requests comments and data regarding any impact on a

manufacturer(s) as a result of extending coverage of the existing

minimum energy efficiency standards to storage-type water heaters of

less than 20 gallons (76 liters). See appendix E to subpart B of Title

10 CFR part 430, sections 1.11, 5.1.4.1, and 5.1.5.

3. First Hour Rating for Storage-type Water Heaters

Water heaters have historically been selected based on rated

storage volume. The rate at which the water heater produces hot water,

and whether the water heater uses a lone or multiple heat source,

however, is also important when selecting a water heater. For example,

a smaller electric water heater having two 4.5-kilowatt elements may

provide more hot water over a given time interval than a larger

electric water heater having a single 3.8-kilowatt element. The first

hour rating seeks to account for the effect of storage capacity,

heating rate, and the number of heat sources on the water heater's

ability to provide hot water. Ideally, the consumer will use first hour

rating to initially identify water heaters that will meet their hot

water supply needs. Once the field has been narrowed based on this

need, the consumer will then use energy factor, annual operating cost,

first cost, warranty information, reputation of manufacturer, etc., in

determining which water heater to select.

The first hour rating is not used in computing the efficiency

(i.e., energy factor) of water heaters, but is used by the Federal

Trade Commission for presenting size ranges in the labeling program for

water heaters. It was hoped that this measure would gain recognition as

a sizing criterion for consumers in selecting water heaters. As a

result, the Department has been conducting a continuous effort to

improve the first hour rating method in rulemakings for water heaters.

However, the concept of what the first hour rating should represent

(i.e., a balance between storage capacity, recovery rate, and mixing

characteristics) and how to measure it accurately has proven to be a

difficult task. Each attempt at establishing a first hour rating test

has led to difficulties (repeatability problem with the 1989 proposal

(54 FR 1890, January 17, 1989), and a low estimate of hot water

availability for certain water heaters by the 1990 final rule. (55 FR

42162, October 17, 1990).) For example, in a October 15, 1991, letter

from GAMA to DOE, GAMA stated that ``Gas Appliance Manufacturers

Association members have results establishing first hour ratings in the

range of 70 to 75 gallons for 120 gallon models. The calculated first

hour rating is significantly less than the amount of water drawn during

the first draw.'' This problem with the October 17, 1990, current test

method is most evident for large tanks with one heating element because

of the greater weighing given by the test procedure to recovery rate

relative to storage volume.

To correct the problem of understating hot water production cited

by GAMA, the Department requested NIST to evaluate a proposal

recommended by GAMA in its October 15, 1991, letter to DOE. GAMA's

recommendation would prorate the final draw of the 1990 first hour

rating test with respect to a ratio of elapsed times. NIST summarized

the advantages and disadvantages of GAMA's recommendation. The major

advantages are: The first hour rating would always be greater than or

equal to the first draw volume and retesting for FTC labeling may be

unnecessary if the needed additional data was collected. The major

disadvantages are: The rating would represent a volume of hot water

that is greater than or equal to the maximum volume of hot water that

can be delivered in an hour (overstating), and it may not differentiate

single-element from two-element electric water heaters (recovery

capabilities unrecognized). The Department, therefore, concludes that

the disadvantages of GAMA's recommendation outweigh the advantages and

rejects this proposal.

The Department requested NIST to conduct a second study to correct

the problem of understating hot water production. NIST recommended that

a revised version of the 1989 test method be proposed. NIST stated its

recommendation will correct the understating problem cited by GAMA in

[[Page 15333]] the October 15, 1991, letter, and in addition, will

minimize the aforementioned repeatability problem. The Department

concurs and today proposes a revised first hour rating method for

storage tank-type (including heat pump) water heaters. Section 5.1.4.

Included in the proposed first hour rating are: Revisions to the test

method for storage tank-type water heaters, hot and cold water mixing

characteristics, and the criterion for initiating successive draws when

conducting a first hour rating test on heat pump water heaters that use

supplemental resistive heating.

In regard to storage tank-type water heaters, for draws initiated

prior to one hour (as a result of a thermostat cut-out), the maximum

outlet temperature shall be determined for each draw and used for

determining when to terminate that draw, i.e., at T*max,i

-25 deg.F, where i corresponds to the draw number. If a recovery is

still in progress at one hour, the draw imposed to remove any stored

``hot'' water shall be terminated based on the cut-off temperature used

for the previous draw (T*max,n-1 -25 deg.F). In addition, for

draws imposed at one hour, the first hour rating shall be the sum of:

All the withdrawn volumes and the final withdrawn volume, where the

final withdrawn volume is multiplied by the following temperature

ratio: (T*del,n-T*min,n-1) /(T*del,n-1 -T*min,n-1).

The subscripts n and n-1 are used to indicate the final draw and the

next-to-last draw, respectively, while T*min,n-1 designates the

water temperature at which the next-to-last draw was terminated

(T*min,n-1 = T*max,n-1 -25 deg.F). For all other draw

volumes, no temperature ratio adjustment factor shall be used.

The Department notes that a temperature ratio can and has been used

in the past to compensate for the amount of mixing that occurs between

the stored hot water and the entering make-up water during a draw. The

greater the volume of make-up water mixed into the outlet stream (while

still maintaining an outlet temperature above the criterion of ``hot''

water), the greater the first hour rating. The amount of mixing is

typically small and repeatable for designs that introduce make-up water

near the bottom of the tank. However, if a water heater uses a

thermally compensating dip tube (first discussed in the February 8,

1984, Proposed Rulemaking, 49 FR 4870), or an internal mixing valve,

substantial mixing, and thus, a higher and unrealistic first hour

rating could occur. At present, DOE is not aware of any currently

manufactured water heaters which contain these features. Therefore, DOE

is not employing a temperature ratio correction to handle mixing

effects. The Department requests comments and data concerning the

appropriateness of today's proposal relative to thermally compensating

dip tubes, internal mixing valves, or any other mechanism used to

increase the amount of mixing of stored hot water and make-up water

during a draw.

The Department also notes that with a multiple draw first hour

rating test, like the one proposed today, a temperature ratio can be

used to compensate for the effect of the test tolerances allowed for

the thermostat setting(s) [5 deg.F

(2.8 deg.C)], and for the make-up water temperature

[2 deg.F (1.1 deg.C)]. These test tolerances

affect the time required for the water heater to recover from a hot

water draw. For example, recovery time is quickest if the tank

thermostat(s) is set to 130 deg.F (54.4 deg.C), and the make-up water

is set at 60 deg.F (15.6 deg.C). Recovery time is slowest for settings

at 140 deg.F (60 deg.C) and 56 deg.F (13.3 deg.C). To avoid the

potential complication and confusion that would result from an

additional temperature ratio correction, however, a test tolerance

correction is not included in today's proposal. The Department

recognizes that an incentive exists to conduct the first hour rating

test with the tank thermostat set at or near 130 deg.F (54.4 deg.C),

and with the make-up water at or near 60 deg.F (15.6 deg.C).

Preliminary studies conducted by NIST estimate today's proposed

test method is successful in minimizing the repeatability problem to

within 5 percent relative to the 1989 proposal. The

Department today requests comments and data concerning this

repeatability issue.

In addition, the Department proposes to modify the existing first

hour rating definition so that it differentiates between storage and

instantaneous water heaters. Section 1.5.

In regard to heat pump water heaters that use supplemental

resistive heating, a draw is currently initiated only after all power

to the water heater has been reduced, which corresponds to the case

where the compressor has cycled off and any resistive heating has

ceased. The Department today proposes a revision to the criterion used

to initiate successive draws so that credit is given if this type of

water heater provides a partial recovery. The proposed revision would

require a draw to be initiated after the thermostat controlling the

upper or lone resistive element, or the compressor is satisfied,

whichever occurs first. However, this criterion shall be applicable

only if the water located vertically above the resistive element

thermostat or compressor thermostat is heated to 135

5 deg.F (57.2 2.8 deg.C) when cut-off occurs. The

Department requests comments and data on the appropriateness and

workability of the proposed changes to the test method for heat pump

water heaters that use supplemental resistive heating. See appendix E

to subpart B of Title 10 CFR part 430, section 5.1.4.2.

4. Definitions for Heat Pump Water Heaters, Add-on Heat Pump Water

Heaters, Integral Heat Pump Water Heaters, Solar Water Heaters, and

Heat Pump Water Heater Storage Tanks

The Department proposes to amend the extant definition for heat

pump water heaters (section 1.11.3); add definitions of integral heat

pump water heater (section 1.11.3.a), add-on heat pump water heaters

(section 1.11.3.b), and solar water heaters (section 1.11.5) to

differentiate these types of water heaters; and add definition of a

heat pump water heater storage tank, i.e., the tank to be used with an

add-on heat pump water heater (section 1.6).

B. Kitchen Ranges, Ovens and Microwave Ovens Test Procedures

The test procedures for kitchen ranges, ovens and microwave ovens

have remained substantially unchanged since the final rule was

published in the Federal Register on May 10, 1978 (43 FR 20120). It was

amended on April 13, 1979, by prescribing that natural gas or propane

would be the test gas used with gas ranges and ovens (44 FR 22418).

Today's proposed amendment will change the annual useful cooking

energy output for kitchen ranges, ovens and microwave ovens to make it

representative of current United States cooking product usage. In

addition, the proposed test procedure will no longer contain annual

energy consumption calculations for ranges (cooktop and oven combined),

or other combined appliances (multiple conventional ovens, microwave

and conventional range combined). The Department is proposing to

calculate the annual energy consumption of combined appliances as the

sum of the annual energy consumption of each individual component of

the unit. Section 4.3. The Department is proposing to incorporate by

reference the International Electrotechnical Commission (IEC),

Publication 705, and Amendment 2-1993, ``Methods for Measuring the

Performance of Microwave Ovens for Household and Similar Purposes,''

Section 4, Paragraph 12 ``Microwave Power Output Measurement,''

Paragraph 13 ``Electrical Power Output Measurement,'' and Paragraph 14

[[Page 15334]] ``Efficiency.'' DOE has not proposed test procedures for

grill and griddle cook tops; the Department would consider adding test

procedures for these products if such exist.

1. Ovens

Today's proposed revision to the oven test procedures lowers the

constant for annual useful cooking energy2 to make it

representative of current United States cooking trends. This quantity

is being changed for electric to 35.5 kWh (105.5 MJ) per year from

47.09 kWh (169.5 MJ) per year; for gas, to 124,200 BTU (131,038 kJ) per

year from 160,700 BTU (169,547 kJ) per year. Sections 4.1.2.1.1,

4.1.2.1.2, and 4.1.4. Lawrence Berkeley Laboratory of Berkeley,

California calculated this constant from several utility studies. These

results are presented in the Technical Support Document: Energy

Efficiency Standards for Consumer Products, Volume 2, November 1993,

DOE/EE-0009, Vol. 2 of 3.

\2\The annual useful cooking energy is energy input to an oven

which is transferred to the product being cooked and is a constant

used to find the annual energy consumption and the energy factor.

The annual energy consumption is calculated by multiplying the

constant by the ratio of test energy consumption to the energy used

to heat the test block. The energy factor is the ratio of the

constant to the total annual energy consumption.

---------------------------------------------------------------------------

In addition, the Department proposes to eliminate the requirement

to use a standard continuous flow calorimeter for gas cooking products

because of the difficulty of locating this product. The instrument to

be substituted for the standard continuous flow calorimeter is left to

the discretion of the manufacturer; although, it is required that the

heating value of natural or propane gas shall be measured with an

instrument and associated indicator readout device of a maximum error

no greater than .5 percent of the measured value and a

resolution of .2 percent or less of the full scale reading

of the indictor instrument. Section 2.9.4.

2. Cook Tops

The proposed revision to the cook top test procedures changes the

constant for annual useful cooking energy3 to make it

representative of current United States cooking trends. This quantity

is being lowered for electric to 209 kWh (752.4 MJ) per year from 277.7

kWh (1000 MJ) per year; for gas, to 732,500 BTU (772,800 kJ) per year

from 947,500 BTU (999,600 kJ) per year. Lawrence Berkeley Laboratory of

Berkeley, California calculated this constant from several utility

studies. These results are presented in the Technical Support Document:

Energy Efficiency Standards for Consumer Products, Volume 2, November

1993, DOE/EE-0009, Vol. 2 of 3.

\3\See footnote 2, supra.

---------------------------------------------------------------------------

3. Microwave Ovens

The proposed changes to the microwave oven test procedures are in

response to a petition for rulemaking from the Association of Home

Appliance Manufacturers (AHAM) to use the International

Electrotechnical Commission standard as the DOE test procedure. The

current DOE test procedure is based on a 1975 version of the

International Electrotechnical Commission standard. The Association of

Home Appliance Manufacturers cited the following deficiencies with the

DOE test procedure:

(1) Errors caused by evaporative cooling of the water and heat

absorption of the water containers during the heating period, and

(2) Errors caused by the constantly changing sodium chloride

concentration due to sodium chloride precipitating out of solution.

The International Electrotechnical Commission issued Publication

705, and Amendment 2-1993 entitled ``Method for Measuring the

Performance of Microwave Ovens for Household and Similar Purposes'' in

1993. The Department asked the National Institute of Standards and

Technology to perform tests using the 1993 International

Electrotechnical Commission test procedure. The National Institute of

Standards and Technology found the test procedure to be acceptable for

determining power output and efficiency, and recommended that the

Department of Energy incorporate by reference the International

Electrotechnical Commission 705 Amendment 2-1993 test procedure for

these purposes. In computing energy consumption, the International

Electrotechnical Commission 705 Amendment 2-1993 uses a watt meter and

timer, ignoring transients, to obtain measurements from which energy

consumption can be calculated. The Department believes that because of

start-up transients, the use of a watt-hour meter is more accurate;

therefore, today's notice includes the use of a watt-hour meter, which

is not found in the IEC 1993 test procedure, to obtain energy

consumption.

The annual useful cooking energy in the extant test procedure is

34.2 kWh (123 MJ) per year based on 1976 data. In the Eight Product

rulemaking (59 FR 10464, March 4, 1994), DOE used an annual useful

cooking energy of 145.8 kWh per year in its analysis. Technical Support

Document: Energy Efficiency Standards for Consumer Products, Volume 2,

November 1993, DOE/EE-0009, Vol. 2 of 3, pp. 1-49. After reviewing

several utility studies and comments, DOE is proposing to change the

annual useful cooking energy4 from 34.2 kWh (123 MJ) per year to

77.3 kWh (278.3 MJ) per year. This revision to the annual useful

cooking energy reflects current U.S. microwave cooking usage. This will

change the value of Om in the test procedure to 77.3 kWh/yr [143.2

kWh/yr x 0.54 = 77.3 kWh/yr] (278.3 MJ/yr). (See appendix I to

subpart B of title 10 CFR part 430, ``Uniform Test Method for Measuring

the Energy Consumption of Conventional Ranges, Conventional Cooking

Tops, Conventional Ovens, and Microwave Ovens,'' sections 4.4.3 and

4.4.5). Lawrence Berkeley Laboratory of Berkeley, California calculated

this constant from an average of six utility studies. These studies

include: Lawrence Berkeley Laboratory, ``Baseline Data for the

Residential and Development of a Residential Forecasting Database,''

LBL 33717, May 1994; American Electric Power, ``Utility Estimates of

Household Appliance Electricity Consumption,'' 1992; Southern

California Edison, ``Residential Appliance End-Use Survey,'' 1990 and

1991; Electric Power Research Institute, ``Residential End-Use Energy

Consumption: A Survey of Conditional Demand Estimates,'' CU-6487,

October 1989; and the Sierra Pacific Power Company, ``Integrating EIP

and HES5 Information for Estimating End-Use Energies,'' March 1988. The

microwave oven annual energy consumption proposed in today's notice

also includes the energy used by the clock thus, eliminating the

necessity to disable the clock during test setup.

\4\The annual useful cooking energy is energy input to an oven

which is transferred to the product being cooked and is a constant

used to find the annual energy consumption and the energy factor.

The annual energy consumption is calculated by multiplying the

constant by the ratio of test energy consumption to the energy used

to heat the test water load. The energy factor is the ratio of the

constant to the total annual energy consumption.

---------------------------------------------------------------------------

C. Clothes Washer Test Procedure

The Department published the clothes washer test procedure on

September 28, 1977, (42 FR 49802) and subsequently on June 29, 1979,

(44 FR 37938) editorial changes were made. On December 22, 1993, (58 FR

67710) the Department published a proposed amendment to the clothes

washer test procedure to address washers which offer a warm rinse lock-

out feature. Today's proposed amendments to the clothes washer test

procedure will [[Page 15335]] address issues that are independent from

the temperature selection lock-out feature.

Today's proposed amendments to the clothes washer test procedure do

not alter the energy factor of any existing clothes washer that

minimally complies with the existing efficiency standard.

In the Advance Notice of Proposed Rulemaking for energy

conservation standards for clothes washers (59 FR 56423, November 14,

1994), the Department said it would consider an energy conservation

standard that includes water extraction. The Department believes that

mechanical water extraction in a clothes washer is much more cost

effective and efficient than thermal extraction in a clothes dryer. The

Department proposes today's procedures and calculations for water

extraction in clothes washers that would be used in the standards

rulemaking for consideration of water extraction. Any analysis for

clothes dryer efficiency standards would account for the impact of

moisture retention of clothes entering the clothes dryer.

The Department of Energy today proposes to modify the clothes

washer test procedure as follows:

1. Title 10 CFR part 430, subpart B, section 430.22(j).

The number of representative average-use cycles per year is

presently 416, based on Proctor and Gamble survey data from 1974-75.

New Proctor and Gamble survey data has indicated the number of cycles

consumers use on a yearly basis has decreased. Thus, the Department is

proposing to revise the representative average-use cycles to 392 per

year.5 This change lowers annual energy use and annual energy

cost.

\5\392 represents the average number of cycles per year from

1986 through 1994, obtained by P & G survey data and provided to the

Department via letter dated September 2, 1994.

---------------------------------------------------------------------------

2. Title 10 CFR part 430, subpart B, appendix J.

a. General test procedure clarification.

The Department is proposing to add a definition for ``agitator''

(section 1.1). The existing test procedure mentions ``agitator'' but,

does not provide a definition.

The Department is proposing to add a definition for

``thermostatically controlled valves'' (section 1.19). The existing

test procedure mentions ``thermostatically controlled valves'' but,

does not provide a definition.

The Department is proposing to replace the definition for a ``top-

loader'' clothes washer with ``top-loader-horizontal-axis clothes

washer'' (section 1.21) and ``top-loader-vertical-axis clothes washer''

(section 1.22). The Department has become aware of top-loading-

horizontal-axis clothes washers which are readily available in other

countries. These clothes washers have not yet become available in the

U.S. market; however, the Department wants to provide nomenclature for

this type of clothes washer.

The Department is proposing to delete the following definitions:

``AHAM'' (section 1.1), ``HWL-1'' (section 1.7) and ``HLW-2EC''

(section 1.8). The revised test procedure proposed in today's notice

does not use these terms.

The Department is proposing to delete the requirement specified in

existing test procedure section 2.2: ``Disconnect all console lights or

other lighting systems on the clothes washer, which do not consume more

than 10 watts during the clothes washer test cycle.'' The Department

believes that this requirement is burdensome.

The Department is proposing to add a new requirement for

``Agitation and spin speed settings'' (section 2.11). The existing test

procedure does not specify agitation or spin speed settings. The

Department is aware of clothes washers which allow selective agitation

and spin speed settings independent of the normal cycle. Therefore, the

proposed test procedure specifies requirements for clothes washers with

these features.

The Department is proposing to change the symbol for density from

``d'' to ``.'' The requirement to use the density of water at

140 deg.F was deleted, so that the density of water at the measured

temperature will be used.

The Department is proposing to clarify the requirement for

``maximum fill'' testing. The Department wants to ensure that testing

of a clothes washer's energy consumption accounts for the clothes

washer's maximum fill capability. The Department is proposing to revise

the test procedure to add ``available on the clothes washer'' after the

test procedure requirement for ``maximum fill'' (sections 3.2.1.2 and

3.2.2.1).

The Department is aware that some clothes washers may have

similarly labeled wash/rinse temperature selections, i.e., ``automatic

warm/cold'' and ``warm/cold,'' on the same machine, which actually

provide different wash/rinse water temperatures. Under this scenario,

the ``automatic warm/cold'' temperature selection has wash/rinse water

temperature adjusted through the use of thermostatically controlled

valves, whereas the ``warm/cold'' temperature selection is

``traditional,'' in that control of temperature is based on preset

orifices. The Department believes that these machines are offering

additional temperature selections. Therefore, instead of developing

additional Temperature Utilization Factors, the Department is proposing

to require the use of the temperature selection which results in the

largest amount of hot water consumption for the energy consumption

calculations (section 4.1.1.1). The Department believes the use of the

temperature selection which results in the largest amount of hot water

consumption is specified in the existing test procedure (``hottest

setting available'' in section 3.2.2.2). The Department's proposal is

intended to remove any ambiguity regarding the testing of clothes

washers equipped with this type of temperature selection. The

Department welcomes comments regarding this issue.

b. Test procedure revisions to include changes from approved

Waivers.

The Department has granted two Petitions for Waivers to the clothes

washer test procedure. Both Waivers were for water-heating clothes

washers. New Harmony Systems Corporation (New Harmony) was issued a

Waiver (Case No. CW-001) by Decision and Order, published on April 4,

1994. (59 FR 15710). Asko Incorporated (Asko) was issued a Waiver (Case

No. CW-002) by Decision and Order, published on April 4, 1994. (59 FR

15719).

The Department is proposing definitions for ``nonwater-heating

clothes washer'' (section 1.11) and ``water-heating clothes washer''

(section 1.24) to differentiate different types of clothes washers.

The Department is proposing to revise the requirements for

``electrical energy supply'' (section 2.2) to allow for higher voltage

clothes washers. Furthermore, voltage tolerance has been increased from

approximately 1.6 percent to 2 percent to reduce testing burden. This

increase in tolerance will not reduce the accuracy of energy

consumption testing/reporting.

The Department is proposing to add procedures for testing water-

heating clothes washers which have variable temperature controls

(sections 3.2.2 through 3.2.2.4). The Department is proposing to test

water-heating clothes washers at the coldest and hottest setting

available on the clothes washer in addition to the existing test

procedure temperature settings for warm (nominally 100 deg.F) and hot

(nominally 140 deg.F).

The proposed temperature use factors for water-heating clothes

washers are based on revised temperature use factors for a three

temperature selection nonwater-heating clothes washer. The Department

believes that the existing TUFs for a three temperature selection

nonwater-heating clothes washer are [[Page 15336]] appropriate for a

water-heating clothes washer, except that some consumers will

occasionally choose to use a temperature setting higher than the

``hot'' setting since it is available to them. The existing temperature

use factors for ``cold/cold'' (15 percent), ``warm/warm or warm/cold''

(55 percent) and ``hot/warm or hot/cold'' (30 percent) have been split

into four TUFs, one of 15 percent for the ``coldest'' setting, one of

55 percent for the ``warm'' setting, one of 25 percent for ``hot'' and

one of 5 percent for the ``hottest'' setting. The Department does not

have data regarding the 5 percent value, but is proposing to use it as

originally proposed by New Harmony. The Department welcomes comments on

this proposal.

The Department is proposing tighter tolerances for the supply water

temperature, and the ``warm'' and ``hot'' settings for water-heating

clothes washers as compared to nonwater-heating clothes washers. The

Department is proposing that the supply water temperature be set at ``a

minimum of 55 deg.F (12.8 deg.C) and a maximum of 60 deg.F

(15.6 deg.C).'' The ``warm'' temperature shall be set at ``a minimum of

100 deg.F (37.8 deg.C) and a maximum of 105 deg.F (40.6 deg.C)'' and

the ``hot'' temperature shall be set at ``a minimum of 140 deg.F

(60 deg.C) and a maximum of 145 deg.F (62.8 deg.C).'' These tighter

tolerances are required for water-heating clothes washers to reduce

variability in energy consumption testing/reporting and to ensure that

a minimum temperature rise is tested. The temperature tolerance and

minimum temperature rise issues are unique to a water-heating clothes

washer because the energy to raise the water temperature is measured

from electrical consumption versus being calculated as it is for

nonwater-heating clothes washers.

Since the issue of machine-controlled water fill capability has

been raised by the Asko Waiver, the Department wants to provide a

provision for the possibility of any type of clothes washer having this

feature. Thus, the Department is proposing to add the definition of

``machine-controlled water fill capability'' (section 1.7) to the test

procedure. In addition, the Department is proposing a revision to the

``top-loader-vertical-axis clothes washer'' section (section 2.8.1) to

require the use of a test load for clothes washers with a machine-

controlled water fill capability feature. Therefore, a clothes washer

equipped with machined-controlled water fill capability will be tested

for maximum fill energy consumption using a 7 pound (3.18 kg) test load

and for minimum fill energy consumption using a 3 pound (1.36 kg) test

load. The Department believes that consumers will occasionally wash

loads which are larger than 7 pounds (3.18 kg) and will also wash loads

which are smaller than 3 pounds (1.36 kg). This provision will allow

for testing of clothes washers that may have this feature. The

Department welcomes comments on this proposed provision.

c. Water consumption and extraction testing.

The Department is concerned about water conservation and wishes to

provide for a procedure to determine the water consumption of clothes

washers. The Department believes, consistent with the Energy Policy Act

of 1992, Pub. L. 102-486, that water conservation is important, and a

need may exist to determine actual water use.

Therefore, the Department is proposing to add definitions, testing

procedures, and calculations regarding water use. Additionally, for

those water or sewage utilities wishing to include particular clothes

washers in rebate programs, the DOE test procedure would provide a

standardized means of testing for water consumption.

The Department is proposing to add a definition for a ``Water

consumption factor'' (section 1.23). Calculations for the water

consumption factor are provided in section 4.3. The water consumption

factor is the ratio of the clothes washer capacity divided by the

weighted per-cycle water consumption. The weighted per-cycle water

consumption is the actual weighted volume of water that a particular

clothes washer consumes. This measurement could be used to estimate

water consumption on an annual basis. The Department welcomes comments

on this proposal.

The Department is concerned about water extraction in the clothes

washers' final spin. The Department believes that mechanical extraction

in a clothes washer is more efficient than thermal extraction in a

clothes dryer. Therefore, the Department wishes to provide for a

procedure measuring the water extraction in clothes washers. The

Department is proposing to add a definition for ``moisture removal

energy'' (section 1.10). Moisture removal energy equals the weight of

the residual water in the test load at the completion of the clothes

washer cycle multiplied by the nominal energy needed to remove moisture

using a representative clothes dryer efficiency. The calculations for

moisture removal energy are provided in the proposed test procedure

section 4.2. In today's notice, the Department requests comments, data,

and other relevant information regarding the definition and calculation

of the moisture removal energy. The Department is proposing a value of

0.5 Kwh/lb as the energy efficiency of a representative clothes dryer

to remove moisture. The Department also is interested in comments as to

the validity and usage of this value.

The Department is interested in developing a new energy descriptor,

called a modified energy factor, which will include moisture removal

energy, for possible future standard use. This new descriptor will

provide a means of determining and comparing the entire energy

consumption of clothes washers. Therefore, the Department is proposing

to add a definition for ``modified energy factor'' (section 1.9). The

modified energy factor equals the ratio of the capacity of the clothes

washer divided by the total energy, which consists of the mechanical,

hot water and moisture removal energy. The calculations for the

modified energy factor are provided in the proposed test procedure

section 4.4. The Department requests comments, data, and other relevant

information regarding the definition and calculation of this new energy

descriptor.

D. Reporting Requirements

The Department is proposing to revise the reporting requirements

for clothes washers, dishwashers and clothes dryers. The present

regulations do not require the reporting of the energy factors for

these products. Prior to the May 14, 1991 final rule for clothes

washers, dishwashers and clothes dryers, there were no performance

standards for these products. Now, since there are performance

standards for these products, the Department is proposing to include

certification reporting. Section 430.62(a)(2).

III. Environmental Review

Pursuant to section 7(a) of the Federal Energy Administration Act

of 1974 (Pub. L. 93-275, 15 U.S.C. 766(a)), a copy of this notice was

submitted to the Administrator of the Environmental Protection Agency

for the Administrator's comments concerning the impacts of this

proposal on the quality of the environment.

DOE has concluded that this proposed rule falls into a class of

actions (categorical exclusion A5) that are categorically excluded from

NEPA review because they would not individually or cumulatively have a

significant impact on the human environment, as determined by DOE's

regulations (10 CFR part 1021, Subpart D) implementing the National

Environmental Policy Act of 1969 (42 U.S.C. 4321, 4331-35, 4341-47

(1976)). [[Page 15337]] Therefore, this proposed rule does not require

an environmental impact statement or an environmental assessment

pursuant to NEPA.

IV. Regulatory Review

Today's regulatory proposal has been determined not to be a

``significant regulatory action'' under Executive Order 12866,

``Regulatory Planning and Review,'' (58 FR 51735, October 4, 1993).

Accordingly, today's action was not subject to review under the

Executive Order by the Office of Information and Regulatory Affairs.

V. Regulatory Flexibility Review

The proposed rule has been reviewed under the Regulatory

Flexibility Act, Pub. L. 96-354 (42 U.S.C. 601-612) which requires

preparation of a regulatory flexibility analysis for any regulation

that will have a significant economic impact on a substantial number of

small entities, i.e., small businesses and small government

jurisdictions. The proposed rule affects manufacturers of water

heaters; kitchen ranges, ovens, and microwave ovens; and clothes

washers. The test procedures would not have significant economic

impact, but rather, would provide common testing methods. DOE

accordingly certifies that the proposed rule would not, if promulgated,

have a significant economic impact on a substantial number of small

entities and that preparation of a regulatory flexibility analysis is

not warranted.

VI. ``Takings'' Assessment Review

It has been determined pursuant to Executive Order 12630 (52 FR

8859, March 18, 1988) that this proposed regulation, if adopted, would

not result in any takings which might require compensation under the

Fifth Amendment to the United States Constitution.

The Department believes that test procedures implementing a long-

established statutory mandate in a manner calculated to minimize

adverse economic impacts does not constitute a ``taking'' of private

property. Thus, testing under the appliance standards program does not

invoke the provisions of E.O. 12630.

VII. Federalism Review

Executive Order 12612 (52 FR 41685, October 30, 1987) requires that

regulations or rules be reviewed for any substantial direct effects on

States, on the relationship between the Federal Government and the

States, or on the distribution of power and responsibilities among

various levels of Government. If there are sufficient substantial

direct effects, the Executive Order 12612 requires the preparation of a

Federalism assessment to be used in decisions by senior policymakers in

promulgating or implementing the regulation.

DOE has identified a substantial direct effect that today's

proposed rule would have on State governments. It would initially

preempt inconsistent State regulations. However, DOE has concluded that

such effect is not sufficient to warrant preparation of a federalism

assessment for the following reason: the Act provided for subsequent

State petitions for exemption. Thus, a determination as to whether a

State law prevails must be made on a case-by-case basis using criteria

set forth in the Act. When DOE receives such a petition, it will then

be appropriate to consider preparing a federalism assessment consistent

with the criteria in the Act.

VIII. Review Under Section 32 of the Federal Energy Administration

Authorization Act

The test procedure amendments proposed today incorporate the

International Electrotechnical Commission Publication 705, and

Amendment 2-1993, ``Methods for Measuring the Performance of Microwave

Ovens for Household and Similar Purposes,'' section 4, Paragraph 12

``Microwave Power Output Measurement,'' Paragraph 13 ``Electrical Power

Output Measurement,'' and Paragraph 14 ``Efficiency'' to determine the

output power and efficiency for microwave ovens.

Pursuant to section 301 of the Department of Energy Organization

Act (Pub. L. 95-91), DOE is required to comply with section 32 of the

Federal Energy Authorization Act of 1974 (15 U.S.C. 788), which imposes

certain requirements where a proposed rule contains commercial

standards or authorizes or requires the use of such standards.

The findings required of DOE by section 32 of the Act serve to

alert the public and DOE regarding the use and background of commercial

standards in a proposal and through the rulemaking process. They allow

interested persons to make known their views regarding the

appropriateness of the use of any particular commercial standard in a

proposed rulemaking.

DOE has evaluated the promulgation of International

Electrotechnical Commission Publication 705, and Amendment 2-1993, in

light of the public participation criteria of section 32(b). The

Department is unable to conclude whether development of these standards

fully complied with section 32(b) regarding the manner of public

participation.

As required by section 32(c), DOE will consult with the Attorney

General and the Chairman of the Federal Trade Commission concerning the

impact of these standards on competition, prior to prescribing final

test procedures.

IX. Paperwork Reduction Act Review

No new information or recordkeeping requirements are imposed by

this rulemaking. Accordingly, no OMB clearance is required under the

Paperwork Reduction Act (44 U.S.C. 3501 et seq.).

X. Review Under Executive Order 12778

Section 2 of Executive Order 12778 instructs each agency to adhere

to certain requirements in promulgating new regulations and reviewing

existing regulations. These requirements, set forth in sections 2(a)

and (b)(2), include eliminating drafting errors and needless ambiguity,

drafting the regulations to minimize litigation, providing clear and

certain legal standards for affected conduct, and promoting

simplification and burden reduction. Agencies are also instructed to

make every reasonable effort to ensure that the regulation specifies

clearly any preemptive effect, effect on existing Federal law or

regulation, and retroactive effect; describes any administrative

proceedings to be available prior to judicial review and any provisions

for the exhaustion of such administrative proceedings; and defines key

terms. The DOE certifies that today's proposed rule meets the

requirements of sections 2(a) and (b)(2) of Executive Order 12778.

XI. Public Comment Procedures

A. Written Comment Procedures

Interested persons are invited to participate in the rulemaking by

submitting data, comments, or information with respect to the proposed

test procedures set forth in this notice to the address indicated at

the beginning of the notice.

Comments should be identified both on the envelope and on the

documents as ``Water Heaters; Kitchen Ranges, Ovens, and Microwave

Ovens; and Clothes Washers Test Procedures, Docket No. EE-RM-94-230.''

Ten (10) copies are requested to be submitted. In addition, the

Department requests that an electronic copy (3\1/2\'' diskette) of the

comments on WordPerfectTM 5.1 be provided. All submittal received by

the date specified at the beginning of this notice will be considered

by the Department of Energy before final action is taken on the

proposed amendments. [[Page 15338]]

Pursuant to the provisions of 10 CFR 1004.11, any person submitting

information which he or she believes to be confidential and exempt by

law from public disclosure should submit one complete copy of the

document and ten (10) copies, if possible, from which the information

believed to be confidential has been deleted. The Department of Energy

will make its own determination with regard to the confidential status

of the information and treat it according to its determination.

Factors of interest to DOE when evaluating requests to treat as

confidential information that has been submitted include: (1) A

description of the items; (2) an indication as to whether and why such

items are customarily treated as confidential within the industry; (3)

whether the information is generally known by or available from other

sources; (4) whether the information has previously been made available

to others without obligation concerning its confidentiality; (5) an

explanation of the competitive injury to the submitting person which

would result from public disclosure; (6) an indication as to when such

information might lose its confidential character due to the passage of

time; and (7) why disclosure of the information would be contrary to

the public interest.

B. Public Hearing

1. Procedures for Submitting Requests to Speak

The time and place of the public hearing are indicated at the

beginning of this notice. The Department of Energy invites any person

who has an interest in today's proposed rule, or who is a

representative of a group or class of persons that has an interest in

the proposed test procedures, to make a written request for an

opportunity to make an oral presentation. Such requests should be

directed to the address indicated at the beginning of this notice.

Requests may be hand delivered to such address between the hours of 8

a.m. and 4 p.m., Monday through Friday, except Federal holidays.

Requests should be labeled ``Test Procedure for Water Heaters; Kitchen

Ranges, Ovens and Microwave Ovens; and Clothes Washers; and Reporting

Requirements for Clothes Washers, Clothes Dryers, and Dishwashers,

Docket No. EE-RM-94-230,'' both on the document and on the envelope.

The person making the request should briefly describe the interest

concerned and state why he or she, either individually or as a

representative of a group or class of persons that have such an

interest, is an appropriate spokesperson, and give a telephone number

where he or she may be contacted.

Each person selected to be heard is requested to submit an advance

copy of their statement prior to the hearing as indicated at the

beginning of this notice. In the event any persons wishing to testify

cannot meet this requirement, that person may make alternative

arrangements with the Office of Hearings and Dockets in advance by so

indicating in the letter requesting to make an oral presentation.

2. Conduct of Hearing

The Department of Energy reserves the right to select the persons

to be heard at the hearing, to schedule the respective presentations,

and to establish the procedures governing the conduct of the hearing.

The length of each presentation is limited to twenty (20) minutes.

A DOE official will be designated to preside at the hearing. The

hearing will not be a judicial or an evidentiary-type hearing, but will

be conducted in accordance with 5 U.S.C. 553 and section 336 of the

Act. At the conclusion of all initial oral statements at each day of

the hearing, each person who has made an oral statement will be given

the opportunity to make a rebuttal statement, subject to time

limitations. The rebuttal statement will be given in the order in which

the initial statements were made. The official conducting the hearing

will accept additional comments or questions from those attending, as

time permits. Any interested person may submit, to the presiding

official, written questions to be asked of any person making a

statement at the hearing. The presiding official will determine whether

the question is relevant, and whether time limitations permit it to be

presented for answer.

Any further procedural rules regarding proper conduct of the

hearing will be announced by the presiding official.

A transcript of the hearing will be made, and the entire record of

this rulemaking, including the transcript, will be retained by DOE and

made available for inspection at the DOE Freedom of Information Reading

Room, U.S. Department of Energy, Forrestal Building, Room 1E-190, 1000

Independence Avenue, SW., Washington, DC 20585, (202) 586-6020, between

the hours of 9 a.m. and 4 p.m., Monday through Friday, except Federal

holidays. Any person may purchase a copy of the transcript from the

transcribing reporter.

C. Issues for Public Comment

The Department of Energy is interested in receiving comments and

data concerning the accuracy and workability of these test procedures.

Also, the Department welcomes discussion on improvements or

alternatives to these approaches. In particular, DOE is interested in

gathering comments on the following:

The appropriateness of including test procedures for

electric and oil instantaneous water heaters.

The impacts on manufacturer(s) as a result of extending

coverage of the existing minimum energy efficiency standards for

electric and oil-fired instantaneous water heaters.

The appropriateness of including the draw schedule and

draw rate of the American National Standards Institute/American Society

of Heating, Refrigerating and Air Conditioning Engineers Standard

118.2-1993 for storage water heaters with rated storage capacities less

than 20 gallons (76 liters).

The impacts on manufacturer(s) as a result of extending

coverage of the existing minimum energy efficiency standards for

storage-type water heaters of less than 20 gallons (76 liters).

The appropriateness of the proposed definition, first hour

rating, for instantaneous and storage water heaters.

The appropriateness of the proposed first hour rating test

method for storage tank-type water heaters.

The appropriateness of a first hour rating which might

give unrealistic results for water heaters containing thermal

compensating dip tubes or internal mixing valves.

The appropriateness of the proposed definitions: heat pump

water heater, add-on heat pump water heater, integral heat pump water

heater, solar water heater, and heat pump water heater storage tank.

The adequateness of the test provisions for heat pump

water heaters regarding the usage of backup electric resistance

element(s).

The appropriateness of the proposed test energy method to

determine the output energy for microwave ovens.

The appropriateness to incorporate by reference the

International Electrotechnical Commission Publication 705, and

Amendment 2-1993, ``Methods for Measuring the Performance of Microwave

Ovens for Household and Similar Purposes,'' section 4, Paragraph 12

``Microwave Power Output Measurement,'' Paragraph 13 ``Electrical Power

Output [[Page 15339]] Measurement,'' and Paragraph 14 ``Efficiency'' as

a test method for microwave ovens.

The appropriateness of the proposed definitions: Agitator,

machine- controlled water fill capability, modified energy factor,

moisture removal factor, nonwater-heating clothes washer,

thermostatically controlled valves, top-loader-horizontal-axis clothes

washer, top- loader-vertical-axis clothes washer, water consumption

factor and water-heating clothes washer.

The appropriateness of the proposed test and performance

measurement methods for water-heating clothes washers.

The appropriateness of using 5 percent and 25 percent to

prorate the ``hottest'' available setting and the ``hot'' setting,

respectively, for water-heating clothes washers.

The appropriateness of a new descriptor (moisture removal

energy) to determine the efficiency of moisture removal from the test

load.

The appropriateness of a new descriptor (water consumption

factor) to determine the water consumption of clothes washers.

The appropriateness of a new efficiency descriptor

(modified energy factor) for possible future use in establishing energy

conservation standards for clothes washers.

List of Subjects in 10 CFR Part 430

Administrative practice and procedure, Energy conservation,

Household appliances, Incorporation by reference.

Issued in Washington, DC, February 8, 1995.

Christine Ervin,

Assistant Secretary, Energy Efficiency and Renewable Energy.

For the reasons set forth in the preamble, part 430 of chapter II

of title 10, of the Code of Federal Regulations is proposed to be

amended as set forth below:

PART 430--ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS

1. The authority citation for Part 430 continues to read as

follows:

Authority: 42 U.S.C. 6291-6309.

2. Section 430.22 is amended by revising paragraph (a)(2)(ii) and

adding paragraph (a)(3)(iv) and adding item number 13 to paragraph

(a)(4) to read as follows:

Sec. 430.22 Reference sources.

(a) * * *

(2) * * *

(ii) U.S. Department of Energy, Office of Energy Efficiency and

Renewable Energy, Hearings and Dockets, Forrestal Building, 1000

Independence Avenue, SW., Washington, DC 20585.

(3) * * *

(iv) Copies of the International Electrotechnical Commission

Publication can be obtained from the American National Standards

Institute, 11 West 42nd Street, New York, New York 10036, (212) 642-

4936.

(4) * * *

13. International Electrotechnical Commission Publication 705,

and Amendment 2-1993, ``Methods for Measuring the Performance of

Microwave Ovens for Household and Similar Purposes,'' Section 4,

Paragraph 12 ``Microwave Power Output Measurement,'' Paragraph 13

``Electrical Power Output Measurement,'' and Paragraph 14

``Efficiency.''

Sec. 430.23 [Amended]

3. Section 430.23, Test procedures for measures of energy

consumption, is amended to read as follows:

A. In Sec. 430.23(i)(1)(iii) (second sentence) replace ``4.3.1,

4.2.2, 4.1.2.5, or 4.1.2.6, 4.4.3, and 4.5.1.3'' with ``4.3, 4.2.2,

4.1.2, and 4.4.3.''

B. In Sec. 430.23(i)(2) (first sentence) replace ``4.2.1.3, 4.1.3

and 4.4.2'' with ``4.2.1, 4.1.3, and 4.4.4.''

C. In Sec. 430.23(i)(3) (first sentence) replace ``4.3.2, and

4.5.2'' with ``4.3'' and replace the comma following ``subpart'' with a

period and remove the remainder of the sentence.

D. In Sec. 430.23(i)(4) (first sentence) replace ``4.3.3, 4.2.3,

4.1.4, 4.4.4 and 4.5.3'' with ``4.3, 4.2.3, 4.1.4, 4.4.5.''

E. In Sec. 430.23(j)(1)(i)(A) replace ``416'' with ``392''.

F. In Sec. 430.23(j)(1)(i)(B) replace ``determined according to

4.6'' with ``determined according to section 4.1.1.6 (nonwater-heating)

or 4.1.2.2 (water-heating)''.

G. In Sec. 430.23(j)(1)(ii) (introductory text) replace ``When gas-

heated or oil-heated water is used, the product of: the representative

average-use cycle of 416 cycles per year'' with ``When gas-heated or

oil-heated water is used, the product of: the representative average-

use cycle of 392 cycles per year (for nonwater-heating clothes

washers)''.

H. In Sec. 430.23(j)(1)(ii)(A) replace ``4.4'' with ``4.1.1.4''.

I. In Sec. 430.23(j)(1)(ii)(B) replace ``in Btu per cycle,

determined according to 4.5'' with ``in Btu per cycle (MJ per kwh),

determined according to section 4.1.1.5''.

J. In Sec. 430.23, paragraph (j)(2) is revised to read as follows:

Sec. 430.23 Test procedures for methods of energy consumption.

* * * * *

(j) * * *

(2)(i) The energy factor for automatic and semi-automatic clothes

washers shall be the quotient of the cubic foot (liter) capacity of the

clothes container as determined in 3.1 of appendix J to this subpart

divided by the clothes washer energy consumption per cycle, expressed

as: (for nonwater-heating clothes washers) the sum of the machine

electrical energy consumption and the hot water energy consumption as

determined in 4.1.1.4 and 4.1.1.3, respectively, of appendix J to this

subpart; (or for water-heating clothes washers) the energy consumption

as determined in 4.1.2.2, of appendix J to this subpart. The result

shall be rounded off to the nearest 0.01 cubic foot per kilowatt-hour

per cycle (0.01 liter per kilowatt-hour per cycle).

(ii) The modified energy factor for automatic and semi-automatic

clothes washers is determined in accordance with section 4.4.1

(nonwater-heating clothes washers) or 4.4.2 (water-heating clothes

washers), of appendix J to this subpart. The result shall be rounded

off to the nearest 0.01 cubic foot per kilowatt-hour per cycle (0.01

liter per kilowatt-hour per cycle).

(iii) The water consumption factor for automatic and semi-automatic

clothes washers is determined in accordance with section 4.3.3, of

appendix J to this subpart. The result shall be rounded off to the

nearest 0.001 cubic foot per gallon per cycle (0.001 liter per liter

per cycle).

* * * * *

4. Appendix E to subpart B of part 430 is revised to read as

follows:

Appendix E to Subpart B of Part 430--Uniform Test Method for Measuring

the Energy Consumption of Water Heaters

1. Definitions

1.1 Cut-in means the time or water temperature when a water

heater thermostat has acted to increase the energy or fuel input to

the heating elements, compressor, or burner.

1.2 Cut-out means the time or water temperature when a water

heater thermostat has acted to reduce to a minimum the energy or

fuel input to the heating elements, compressor, or burner.

1.3 Design Power Rating means the nominal power rating that a

water heater manufacturer assigns to a particular design of water

heater, expressed in kilowatts or Btu (KJ) per hour as appropriate.

1.4 Energy Factor means a measure of water heater overall

efficiency.

1.5 First Hour Rating is an estimate of the maximum volume of

``hot'' water that a storage-type water heater can supply within an

hour that begins with the water heater [[Page 15340]] fully heated

(i.e., all thermostats satisfied). For instantaneous water heaters,

first hour rating designates the maximum volume of hot water that

can be supplied during any hour.

1.6 Heat Pump Water Heater Storage Tank is an insulated tank

designed, wired and labeled for use exclusively with an add-on heat

pump water heater or solar water heater and being unable to operate

without an add-on heat pump water heater or solar water heater. The

heat pump water heater storage tank may contain one or two

thermostats and up to two electric resistance heating elements, and

has a manufacturer's rated capacity of 120 gallons (450 liters) or

less. When tested with the add-on heat pump water heater or solar

water heater inoperative, the heat pump water heater storage tank

shall have an energy factor that is determined in accordance with

the test procedure for water heaters.

1.7 Heat Trap means a device which can be integrally connected

or independently attached to the hot and/or cold water pipe

connections of a water heater such that the device will develop a

thermal or mechanical seal to minimize the recirculation of water

due to thermal convection between the water heater tank and its

connecting pipes.

1.8 Instantaneous-Type Water Heaters.

1.8.1 Electric Instantaneous Water Heater means a water heater

that uses electricity as the energy source, initiates heating based

on sensing water flow, is designed to deliver water at a controlled

temperature of less than 180 deg.F (82 deg.C), has a maximum input

of 12 kilowatts or less, and has a manufacturer's specified storage

capacity of less than 2 gallons (8 liters). The unit may use a fixed

or variable power input.

1.8.2 Gas Instantaneous Water Heater means a water heater that

uses gas as the energy source, initiates heating based on sensing

water flow, is designed to deliver water at a controlled temperature

of less than 180 deg.F (82 deg.C), has an input greater than 50,000

Btu per hour (53 MJ per hour) but less than 200,000 Btu per hour

(210 MJ per hour), and has a manufacturer's specified storage

capacity of less than 2 gallons (8 liters). The unit may use a fixed

or variable burner input.

1.8.3 Oil Instantaneous Water Heater means a water heater that

uses oil as the energy source, initiates heating based on sensing

water flow, is designed to deliver water at a controlled temperature

of less than 180 deg.F (82 deg.C), has an input greater than 50,000

Btu per hour (53 MJ per hour) but less than 200,000 Btu per hour

(210 MJ per hour), and has a manufacturer's specified storage

capacity of less than 2 gallons (8 liters). The unit may use a fixed

or variable burner input.

1.9 Recovery Efficiency means the ratio of energy delivered to

the water to the energy content of the fuel consumed by the water

heater.

1.10 Standby means the time during which water is not being

withdrawn from the water heater. There are two standby time

intervals used within this test procedure: stby,1

represents the elapsed time between the time at which the maximum

mean tank temperature is observed after the sixth draw and

subsequent recovery and the end of the 24-hour test;

stby,2 represents the total time during the 24-hour

simulated use test when water was not being withdrawn from the water

heater.

1.11 Storage-Type Water Heaters.

1.11.1 Electric storage water heater means a water heater that

uses electricity as the energy source, is designed to heat and store

water at a thermostatically controlled temperature of less than

180 deg.F (82 deg.C), has a nominal input of 12 kilowatts or less,

and has a manufacturer's rated storage capacity of 120 gallons (450

liters) or less.

1.11.2 Gas Storage Water Heater means a water heater that uses

gas as the energy source, is designed to heat and store water at a

thermostatically controlled temperature of less than 180 deg.F

(82 deg.C), has a nominal input of 75,000 Btu per hour (79 MJ per

hour) or less, and has a manufacturer's rated storage capacity of

100 gallons (380 liters) or less.

1.11.3 Heat Pump Water Heater means a water heater that uses

electricity as the energy source, is designed to heat and store

water at a thermostatically controlled temperature of less than

180 deg.F (82 deg.C), has a maximum current rating of 24 amperes

(includes the compressor and all auxiliary equipment such as fans,

pumps, and controls, and if on the same circuit, any resistive

elements) for an input voltage of 250 volts or less, and, if the

tank is supplied, has a manufacturer's rated storage capacity of 120

gallons (450 liters) or less. Resistive elements used to provide

supplemental heating may use the same circuit as the compressor if

(1) An interlocking mechanism prevents concurrent compressor

operation and resistive heating, or (2) concurrent operation does

not result in the maximum current rating of 24 amperes being

exceeded. Otherwise, separate circuits shall be used by the

resistive elements and the heat pump components. A heat pump water

heater may be an integral type or an add-on type.

a. Integral heat pump water heater--An air-to-water heat pump

integral with an insulated storage tank.

b. Add-on heat pump water heater--An air-to-water heat pump

designed for use with a heat pump water heater storage tank.

1.11.4 Oil Storage Water Heater means a water heater that uses

oil as the energy source, is designed to heat and store water at a

thermostatically controlled temperature of less than 180 deg.F

(82 deg.C), has a nominal energy input of 105,000 Btu/hr (110 MJ/hr)

or less, and has a manufacturer's rated storage capacity of 50

gallons (190 liters) or less.

1.11.5 Solar Water Heater means a water heater that is designed

to obtain at least half of the annual energy for heating water from

the sun.

1.12 ASHRAE Standard 41.1-86 means the standard published in

1986 by the American Society of Heating, Refrigerating and Air-

Conditioning Engineers, Inc. and titled Standard Measurement Guide:

Section on Temperature Measurements.

1.13 ASTM-D-2156-80 means the test standard published in 1980

by the American Society of Testing and Measurements and titled

Method for Smoke Density in Flue Gases from Burning Distillate

Fuels.

1.14 Rated Storage Volume means the water storage capacity of a

water heater, in gallons (liters), as specified by the manufacturer.

2. Test Conditions

2.1 Installation Requirements. Tests shall be performed with

the water heater and instrumentation installed in accordance with

Section 4 of this appendix.

2.2 Ambient Air Temperature. The ambient air temperature shall

be controlled to a value between 65.0 deg.F and 70.0 deg.F

(18.3 deg.C and 21.1 deg.C) on a continuous basis. For heat pump

water heaters, the dry bulb temperature shall be maintained at

67.5 deg.F 1 deg.F (19.7 deg.C 0.6 deg.C)

and, in addition, the relative humidity shall be maintained between

49 and 51 percent.

2.3 Supply Water Temperature. The temperature of the water

being supplied to the water heater shall be maintained at

58 deg.F 2 deg.F (14.4 deg.C1.1 deg.C)

throughout the test.

2.4 Storage Tank Temperature. The average temperature of the

water within the storage tank shall be set to

135 deg.F5 deg.F (57.2 deg.C2.8 deg.C).

2.5 Supply Water Pressure. During the test when water is not

being withdrawn, the supply pressure shall be maintained between 40

psig (275 kPa) and the maximum allowable pressure specified by the

water heater manufacturer.

2.6 Electrical and/or Fossil Fuel Supply.

2.6.1 Electrical. Maintain the electrical supply voltage to

within 1 percent of the center of the voltage range

specified by the water heater and/or heat pump manufacturer.

2.6.2 Natural Gas. Maintain the supply pressure in accordance

with the manufacturer's specifications. If the supply pressure is

not specified, maintain a supply pressure of 7 to 10 inches of water

column (1.7 Kpa to 2.5 Kpa). If the water heater is equipped with a

gas appliance pressure regulator, the regulator outlet pressure

shall be within 10% of the manufacturer's specified

manifold pressure. Use natural gas having a higher heating value of

approximately 1,025 Btu per standard cubic foot (38190 KJ per

standard cubic meter).

2.6.3 Propane Gas. Maintain the supply pressure in accordance

with the manufacturer's specifications. If the supply pressure is

not specified, maintain a supply pressure of 11 to 13 inches of

water column (2.7 kPa to 3.2 kPa). If the water heater is equipped

with a gas appliance pressure regulator, the regulator outlet

pressure shall be within 10% of the manufacturer's

specified manifold pressure. Use propane gas with a higher heating

value of approximately 2,500 Btu per standard cubic foot (93 kJ per

standard cubic meter).

2.6.4 Fuel Oil Supply. Maintain an uninterrupted supply of fuel

oil. Use fuel oil having a heating value of approximately 138,700

Btu per gallon (38,660 kJ per liter).

3. Instrumentation

3.1 Pressure Measurements. Pressure measuring instruments shall

have an error no greater than the following values:

[[Page 15341]]

------------------------------------------------------------------------

Item measured Instrument accuracy Instrument precision

------------------------------------------------------------------------

Gas pressure........ 0.1 inch of 0.05 inch

water column ( 0.025 kPa). minus> 0.012 kPa).

Atmospheric pressure 0.1 inch of 0.05 inch

mercury column ( 0.34 kPa). ( 0.17

kPa).

Water pressure...... 1.0 pounds 0.50 pounds

per square inch ( 6.9 kPa). minus> 3.45 kPa).

------------------------------------------------------------------------

3.2 Temperature Measurement.

3.2.1 Measurement. Temperature measurements shall be made in

accordance with the Standard Measurement Guide: Section on

Temperature Measurements, ASHRAE Standard 41.1-86.

3.2.2 Accuracy and Precision. The accuracy and precision of the

instruments, including their associated readout devices, shall be

within the limits as follows:

----------------------------------------------------------------------------------------------------------------

Item measured Instrument accuracy Instrument precision

----------------------------------------------------------------------------------------------------------------

Air dry bulb temperature................................ 0.2 deg.F 0.1 deg.F

( 0.1 deg.C). ( 0.06

deg.C).

Air wet bulb temperature................................ 0.2 deg.F 0.1 deg.F

( 0.1 deg.C). ( 0.06

deg.C).

Inlet and outlet water temperatures..................... 0.2 deg.F 0.1 deg.F

( 0.1 deg.C). ( 0.06

deg.C).

Storage tank temperatures............................... 0.5 deg.F 0.25 deg.F

( 0.3 deg.C). ( 0.14

deg.C).

----------------------------------------------------------------------------------------------------------------

3.2.3 Scale Division. In no case shall the smallest scale

division of the instrument or instrument system exceed 2 times the

specified precision.

3.2.4 Temperature Difference. Temperature difference between

the entering and leaving water may be measured with any of the

following:

a. A thermopile

b. Calibrated resistance thermometers

c. Precision thermometers

d. Calibrated thermistors

e. Calibrated thermocouple

f. Quartz thermometers

3.2.5 Thermopile Construction. If a thermopile is used, it

shall be made from calibrated thermocouple wire taken from a single

spool. Extension wires to the recording device shall also be made

from that same spool.

3.2.6 Time Constant. The time constant of the instruments used

to measure the inlet and outlet water temperatures shall be no

greater than 5 seconds.

3.3 Liquid Flow Measurements. The accuracy of the liquid flow

rate measurement, using the calibration if furnished, shall be equal

to or less than 1% of the measured value in mass units

per unit time.

3.4 Electric Energy. The electrical energy used shall be

measured with an instrument and associated readout device that are

accurate within 1% of the reading.

3.5 Fossil Fuels. The quantity of fuel used by the water heater

shall be measured with an instrument and associated readout device

that is accurate within 1% of the reading.

3.6 Mass Measurements. For mass measurements greater than or

equal to 10 pounds (4.5 kg), a scale that is accurate within

1.0% of the reading shall be used to make the

measurement. For mass measurements less than 10 pounds (4.5 kg), the

scale shall provide a measurement that is accurate within

0.1 pound (0.045 kg).

3.7 Heating Value. The higher heating value of the natural gas,

propane, or fuel oil shall be measured with an instrument and

associated readout device that is accurate within 1% of

the reading. The heating value of natural gas and propane must be

corrected for local temperature and pressure conditions.

3.8 Time. The elapsed time measurements shall be measured with

an instrument that is accurate within 0.5 seconds per

hour.

4. Installation

4.1 Water Heater Mounting. A water heater designed to be free

standing shall be installed according to the manufacturer's

directions on a \3/4\ inch (2 cm) thick plywood platform supported

by three 2 x 4 inch (5 cm x 10 cm) runners. If the water heater is

not approved for installation on combustible flooring, suitable non-

combustible material shall be placed between it and the platform.

For heat pump water heaters without a storage tank supplied by the

manufacturer, connections shall be made with a storage tank as

described in section 4.10 and in accordance with manufacturer-

published installation instructions. The storage tank and heat pump

section shall be placed on platform(s) constructed as previously

described. If installation materials are not provided by the heat

pump manufacturer, use uninsulated 8 foot (2.4 m) long connecting

hoses, having an inside diameter of \5/8\ inch (1.6 cm). Wall

mounted water heaters shall be installed in accordance with

manufacturer-published installation instructions on a simulated wall

section made from \3/4\ inch (2 centimeter) plywood and 2 x 4 inch

(5 x 10 centimeter) studs. Placement in the test room shall be in an

area protected from drafts.

4.2 Water Supply. The water supply shall be capable of

delivering water at conditions as specified in sections 2.3 and 2.5.

4.3 Water Inlet and Outlet Configuration. Inlet and outlet

piping connections shall be configured as illustrated in Figures 1,

2, or 3. For water heaters that are 36 inches (91 centimeters) or

less in height and intended for installation either beneath,

adjacent to, or in conjunction with a counter (commonly referred to

as an under-the-counter or table-top model), the inlet and outlet

connections shall be configured as illustrated in Figures 4a and 4b.

Type ``L'' hard copper tubing, the same size as the connections on

the water heater, shall be connected to the tank and extend 24

inches (61 centimeters) in length. If an under-the-counter type

water heater is not factory equipped with pipe to extend the field

connection point of the water heater lines to outside of the jacket

or cabinet, type ``L'' hard copper tubing shall be used to extend

the water line horizontally to the exterior of the jacket or

cabinet. Unions may be used to facilitate installation and removal

of the piping arrangements. A pressure gauge and diaphragm expansion

tank shall be installed in the supply water piping at a location

upstream of the 24-inch (61 centimeters) cold water inlet pipe. An

appropriately rated pressure and temperature relief valve shall be

installed on all water heaters at the port specified by the

manufacturer. Discharge piping for the relief valve shall be non-

metallic. If heat traps and/or piping insulation and/or pressure

relief valve insulation are supplied with the water heater, they

shall be installed for testing. Clearance shall be provided such

that none of the piping contacts other surfaces in the test room.

4.4 Fuel and/or Electrical Power and Energy Consumption.

Install one or more instruments which measure, as appropriate, the

quantity and rate of electrical energy and/or fossil fuel

consumption in accordance with Section 3. For heat pump water

heaters that use supplemental resistive heating, the electrical

energy supplied to the resistive element(s) shall be metered

separately from the electrical energy supplied to the entire

appliance or to the remaining components (i.e., compressor, fans,

pumps, controls, etc.).

4.5 Internal Storage Tank Temperature Measurements. Install six

temperature measurement sensors inside the water heater tank with a

vertical distance of at least 4 inches (10 centimeters) between

successive sensors. A temperature sensor shall be positioned at the

vertical midpoint of each of the six equal volume nodes within the

tank. Nodes designate the equal volumes used to evenly partition the

total volume of the tank. As much as is possible, the temperature

sensor should be positioned away from any heating elements, anodic

protective devices, tank walls, and flue pipe walls. If the tank

cannot accommodate six temperature sensors and meet the installation

requirements specified above, install the maximum number of sensors

which comply with the installation requirements. The temperature

sensors shall be installed either through (1) the anodic device

opening; (2) the relief valve opening; or (3) the hot water outlet.

If [[Page 15342]] installed through the relief valve opening or the

hot water outlet, a tee fitting or outlet piping, as applicable,

shall be installed as close as possible to its original location. If

the relief valve temperature sensor is relocated, and it no longer

extends into the top of the tank, a substitute relief valve that has

a sensing element that can reach into the tank shall be installed.

If the hot water outlet includes a heat trap, the heat trap shall be

installed on top of the tee fitting. Added fittings shall be covered

with thermal insulation having an R value between 4 and 8

hrft2 deg.F/Btu (0.7 and 1.4

m2 deg.C/W).

BILLING CODE 6450-01-P

[GRAPHIC][TIFF OMITTED]TP23MR95.000

[[Page 15343]]

[GRAPHIC][TIFF OMITTED]TP23MR95.001

BILLING CODE 6450-01-C

[[Page 15344]]

4.6 Ambient Temperature. The ambient air temperature shall be

measured approximately at the vertical mid-point of the water heater

and approximately 2 feet (60 centimeters) from the surface of the

water heater. The sensor shall be shielded against radiation.

4.7 Inlet and Outlet Water Temperature Measurements. Install

temperature sensors in the cold-water inlet pipe and hot-water

outlet pipe as shown in Figures 1, 2, 3, or 4a and 4b, as

applicable.

4.8 Flow Control. A flow control valve shall be installed to

provide flow as specified in Section 5.

4.9 Flue Requirements.

4.9.1 Gas-Fired Water Heaters. Establish a natural draft in the

following manner. For gas-fired water heaters having a vertically

discharging draft hood outlet, a 5-foot (1.5 meter) vertical vent

pipe extension having a diameter equal to the largest flue collar

size of the draft hood shall be connected to the draft hood outlet.

For gas-fired water heaters having a horizontally discharging draft

hood outlet, a 90-degree elbow having a diameter equal to the

largest flue collar size of the draft hood shall be connected to the

draft hood outlet. A 5-foot (1.5 meter) length of vent pipe shall be

connected to the elbow and oriented to discharge vertically upward.

Direct vent gas-fired water heaters shall be installed with venting

equipment specified in the manufacturer's instructions using the

minimum vertical and horizontal lengths of vent pipe recommended by

the manufacturer.

4.9.2 Oil-Fired Water Heaters. Establish a draft at the flue

collar as specified in the manufacturer's literature. Establish the

draft by using a sufficient length of vent pipe connected to the

water heater flue outlet and directed vertically upward. For an oil-

fired water heater having a horizontally discharging draft hood

outlet, a 90-degree elbow having a diameter equal to the largest

flue collar size of the draft hood shall be connected to the draft

hood outlet. A length of vent pipe sufficient to establish the draft

shall be connected to the elbow fitting and oriented to discharge

vertically upward. Direct vent oil-fired water heaters should be

installed with venting equipment as specified in the manufacturer's

instructions, using the minimum vertical and horizontal lengths of

vent pipe recommended by the manufacturer.

4.10 Heat Pump Water Heater Storage Tank. The heat pump water

heater storage tank to be used for testing a heat pump water heater

without a tank supplied by the manufacturer shall have a volume of

47.0 gallons 1.0 gallon C 1804 liters with

an Energy Factor of 0.87.01 as determined in accordance

with Section 6.1.7 with two 4.5 kW heating elements controlled in

such a manner as to prevent both elements from operating

simultaneously.

5. Test Procedures

5.1 Storage-Type Water Heaters, Including Heat Pump Water

Heaters.

5.1.1 Determination of Storage Tank Volume. Determine the

storage capacity, Vst, of the water heater under test, in gallons

(liters), by subtracting the tare weight--measured while the tank is

empty--from the gross weight of the storage tank when completely

filled with water (with all air eliminated and line pressure applied

as described in section 2.5) and dividing the resulting net weight

by the density of water. Density shall be evaluated based on the

temperature of the stored water.

5.1.2 Setting the Thermostat for a Thermostatically Operated

Water Heater. Starting with a tank of supply water, initiate normal

operation of the water heater. After cutout, determine the mean tank

temperature (based on all of the in-tank sensors) every minute until

the maximum value is observed. Determine whether this maximum value

for the mean tank temperature is within the range of

135 deg.F5 deg.F (57.2 deg.C2.8 deg.C). If

not, turn off the water heater, adjust the thermostat, and refill

the tank with supply water. Then, initiate normal operation of the

water heater, and once again determine the maximum mean tank

temperature after cut-out. Repeat this sequence until the maximum

mean tank temperature after cut-out is within the range of

135 deg.F5 deg.F (57.2 deg.C2.8 deg.C).

If an electric water heater has two or more thermostats, the

thermostat that controls the upper-most heating element shall be set

first to yield a maximum water temperature of

135 deg.F5 deg.F (57.2 deg.C2.8 deg.C), as

measured by the in-tank sensors that are positioned above the upper-

most heating element. The thermostat that controls the heating

element positioned next highest in the tank shall then be set to

yield a maximum water temperature of 135 deg.F5 deg.F

(57.2 deg.C2.8 deg.C). This process shall be repeated

until the thermostat controlling the lowest element is correctly

adjusted. When adjusting the thermostat that controls the lowest

element, the maximum mean tank temperature after cut-out, as

determined using all the in-tank sensors, shall be within

135 deg.F5 deg.F (57.2 deg.C2.8 deg.C). When

adjusting all other thermostats, use only the in-tank temperature

sensors positioned above the heating element in question to evaluate

the maximum water temperature after cut-out.

For heat pump water heaters, which control an auxiliary

resistance element, the thermostat shall be set in accordance with

the manufacturer's installation instructions.

5.1.3 Power Input Determination. For all water heaters except

electric types having immersed heating elements, initiate normal

operation and determine the power input, P, to the main burners

(including pilot light power, if any) after 15 minutes of operation.

If the water heater is equipped with a gas appliance pressure

regulator, the regulator outlet pressure shall be set within

10% of that recommended by the manufacturer. For oil-

fired water heaters the fuel pump pressure shall be within

10% of the manufacturer's specified pump pressure. All

burners shall be adjusted to achieve an hourly Btu (kJ) rating that

is within 2% of the value specified by the manufacturer.

For an oil-fired water heater, adjust the burner to give a CO2

reading recommended by the manufacturer and an hourly Btu (kJ)

rating that is within 2% of that specified by the

manufacturer. Smoke in the flue may not exceed No. 1 smoke as

measured by the procedure in ASTM-D-2156-80.

5.1.4 First Hour Rating Test.

5.1.4.1 General. During hot water draws, remove water at a rate

of 3.000.25 gallons per minute (11.40.95

liters per minute) for units with rated storage capacities of 20

gallons (76 liters) or more and 1.00.25 gallons per

minute (3.80.95 liters per minute) for units with rated

storage capacities less than 20 gallons (76 liters). Collect the

water in a container that is large enough to hold the volume removed

during an individual draw and suitable for weighing at the

termination of each draw. Alternatively, a water meter may be used

to directly measure the water volume(s) withdrawn.

5.1.4.2 Draw Initiation Criterion. Begin the first hour rating

test by imposing a draw on the storage-type water heater. After

completion of this first draw, initiate successive draws based on

the following criteria. For gas- and oil-fired water heaters,

initiate successive draws when the thermostat acts to reduce the

supply of fuel to the main burner. For electric water heaters having

a single element or multiple elements that all operate

simultaneously, initiate successive draws when the thermostat acts

to reduce the electrical input supplied to the element(s). For

electric water heaters having two or more elements that do not

operate simultaneously, initiate successive draws when the

applicable thermostat acts to reduce the electrical input to the

element located vertically highest in the storage tank. For heat

pump water heaters that do not use supplemental resistive heating,

initiate successive draws immediately after the electrical input to

the compressor is reduced by the action of the water heater's

thermostat. For heat pump water heaters that do use supplemental

resistive heating, initiate successive draws immediately after the

electrical input to the compressor or the uppermost resistive

element is reduced by the action of the applicable water heater

thermostat. This draw initiation criterion for heat pump water

heaters that use supplemental resistive heating, however, shall only

apply when the water located above the thermostat at cut-out is

heated to 135 deg.F 5 deg.F

(57.2 deg.C2.8 deg.C).

5.1.4.3 Test Sequence. Establish normal water heater operation.

If the water heater is not presently operating, initiate a draw. The

draw may be terminated anytime after cut-in occurs. Once cut-out

occurs (e.g., all thermostats satisfied), monitor the internal

storage tank temperature sensors described in section 4.5 every

minute. For each set of measurements, calculate the mean tank

temperature. If any of these mean values are outside the range

specified in section 2.4, adjust the thermostat(s) as specified in

section 5.1.2 and reevaluate the mean tank temperature after all

thermostats are again satisfied.

Initiate a draw after a maximum mean tank temperature has been

observed following cut-out. Record the time when the draw is

initiated and designate it as an elapsed time of zero,

(* = 0). The superscript * is used to denote variables

pertaining to the first hour rating test. Record the outlet water

temperature beginning 15 seconds after the draw is initiated and at

5 second intervals thereafter, until the draw is terminated.

Determine the maximum outlet temperature that occurs during this

first draw and record [[Page 15345]] it as T*max,1. For

the duration of this first draw and all successive draws, in

addition, monitor the inlet temperature to the water heater to

assure that the required 58 deg.F2 deg.F (14.4 deg.C

1.1 deg.C) test condition is met. Terminate the hot

water draw when the outlet temperature decreases to

T*max,1 - 25 deg.F (T*max,1-13.9 deg.C). Record

this temperature as T*min,1. Following draw termination,

determine the average outlet water temperature and the mass or

volume removed during this first draw and record them as

T*del,1 and M*1 or V*1, respectively.

Initiate a second and, if applicable, successive draws each time

the applicable draw initiation criterion described in section

5.1.4.2 is satisfied. As required for the first draw, record the

outlet water temperature beginning 15 seconds after initiating each

draw and at 5 second intervals thereafter until the draw is

terminated. Determine the maximum outlet temperature that occurs

during each draw and record it as T*max,i, where i

refers to the draw number. Terminate each hot water draw when the

outlet temperature decreases to T*max,i - 25 deg.F

(T*max,i - 13.9 deg.C). Record this temperature as

T*min,i. Calculate and record the average outlet

temperature and the mass or volume removed during each draw

(T*del,i and M*i or V*i). Continue

this sequence of draw and recovery until one hour has elapsed, at

which time the electrical power and/or the fuel supplied to the

water heater shall be disconnected and/or terminated.

If a draw is occurring at an elapsed time of one hour, continue

this draw until the outlet temperature decreases to

T*max,n - 25 deg.F (T*max,n - 13.9 deg.C), at

which time the draw shall be immediately terminated. The subscript

n shall be used to denote quantities associated with the final

draw. If a draw is not occurring at an elapsed time of one hour, a

final draw shall be imposed at one hour. This draw shall be

immediately terminated when the outlet temperature first indicates a

value less than or equal to the cut-off temperature used for the

previous draw (T*min,n-1). For cases where the outlet

temperature is close to T*min,n-1, the final draw shall

proceed for a minimum of 30 seconds. If an outlet temperature

greater than T*min,n-1 is not measured within 30 seconds,

the draw shall be immediately terminated and zero additional credit

shall be given towards first hour rating (i.e., M*n = 0 or

V*n = 0). Once the final draw is terminated, calculate and

record the average outlet temperature and the mass or volume removed

during the draw (T*del,n and M*n or

V*n).

5.1.5 24-Hour Simulated Use Test. During the simulated use

test, a total of 64.3 1 gallon (2434 liters)

shall be removed if the rated storage tank volume is 20 gallons (76

liters) or greater. If the rated storage tank volume is less than 20

gallons (76 liters) but greater than or equal to 10 gallons (38

liters), a total of 240.5 gallon (911.9

liters) shall be removed; and if the rated storage tank volume is

less than 10 gallons (38 liters), a total of 90.5 gallon

(341.9 liters) shall be removed. These values are

referred to as the daily hot water usage in the following text.

With the water heater turned off, fill the water heater with

supply water and apply pressure as described in section 2.5. Turn on

the water heater and associated heat pump unit, if present. After

the cutout occurs, measure the mean tank temperature using the

temperature sensors described in section 4.5 every minute until the

maximum mean storage tank temperature is achieved. If this maximum

mean temperature is outside the range specified in section 2.4,

adjust the thermostat(s) as specified in section 5.1.2 and

reevaluate the mean tank temperature after all thermostats are again

satisfied. After thermostat adjustments are completed, the water

heater may be operated for up to three cycles of drawing until cut-

in and then operating until cut-out, prior to the start of the test.

At this time, record the mean tank temperature (To), and

the electrical and/or fuel measurement readings, as appropriate.

Begin the 24-hour simulated use test by withdrawing a volume from

the water heater that equals one-sixth of the daily hot water usage.

Record the time when this first draw is initiated and assign it as

the test elapsed time () of zero. Record the average

storage tank and ambient temperature every 15 minutes throughout the

24-hour simulated use test unless a recovery or a draw is occurring.

At elapsed time intervals of one, two, three, four, and five hours

from = 0, initiate additional draws removing an amount of

water equivalent to one-sixth of the daily hot water usage with the

maximum allowable deviation for any single draw being

0.5 gallons (1.9 liters) for units having

rated storage capacities of 20 gallons (76 liters) or greater, and

0.1 gallons (0.4 liters) for units having rated storage

capacities less than 20 gallons (76 liters). The quantity of water

withdrawn during the sixth draw shall be increased or decreased as

necessary such that the total volume of water withdrawn equals:

64.31.0 gallons (243.43.8 liters) for water

heaters having rated storage capacities of 20 gallons (76 liters) or

more, 240.5 gallons (90.81.9 liters) for

water heaters having rated storage capacities less than 20 gallons

(76 liters) but greater than or equal to 10 gallons (38 liters), and

9.00.5 gallons (34.11.9 liters) for water

heaters having rated storage capacities less than 10 gallons (38

liters).

All draws during the simulated use test shall be made at flow

rates of 3.00.25 gallons per minute

(11.40.95 liters per minute) when testing water heaters

having rated storage capacities of 20 gallons (76 liters) or more.

For water heaters having rated storage capacities less than 20

gallons (76 liters), flow rates of 1.00.25 gallons per

minute (3.80.95 liters per minutes) shall be achieved.

Measurements of the inlet and outlet temperatures shall be made

beginning 15 seconds after the draw is initiated and at every

subsequent 5 second interval throughout the duration of each draw.

The arithmetic mean of the hot water discharge temperature and the

cold water inlet temperature shall be determined for each draw

(Tdel,i and Tin,i). Determine and record the net mass or

volume removed (Mi or Vi), as appropriate, after each

draw.

At the end of the recovery period following the first draw,

record the maximum mean tank temperature observed after cut-out,

Tmax,1, and the energy consumed by a gas or oil water heater,

Qr. For heat pump water heaters, the total electrical energy

consumed by the heat pump (including compressor, fan, controls,

pump, etc.) and, if applicable, by the resistive element(s) during

the first recovery shall be recorded as Qr. In addition, the

total operating time of the compressor during the first recovery

shall be determined and recorded as cmp,1. Finally,

for heat pump water heaters that use resistive heating during the

first recovery, the electrical energy consumed by the resistive

element(s) shall be separately metered and recorded, Qres,1.

At the end of the recovery period that follows the sixth draw,

determine and record the total electrical energy and/or fossil-fuel

consumed since the beginning of the test, Qsu. In preparation

for determining the energy consumed during stand-by, record the

reading given on the electrical energy (watt-hour) meter, the gas

meter, and/or the scale used to determine oil consumption, as

appropriate. Record the maximum value of the mean tank temperature

after cutout as Tsu. Except as noted below, allow the water

heater to remain in the standby mode until 24-hours have elapsed

from the start of the test, i.e., since = 0. Prevent the

water heater from beginning a recovery cycle during the last hour of

the test by turning off the electric power to the electrical heating

elements and heat pump, if present, or by turning down the fuel

supply to the main burner at an elapsed time of 23 hours. If a

recovery is taking place at an elapsed time of 23 hours, wait until

the recovery is complete before reducing the electrical and/or fuel

supply to the water heater. At 24 hours, record the mean tank

temperature, T24, and the electric and/or fuel instrument

readings. Determine the total fossil fuel or electrical energy

consumption, as appropriate, for the entire 24-hour simulated use

test, Q. Record the time interval between the time at which the

maximum mean tank temperature is observed after the sixth draw and

the end of the 24-hour test as stby,1. Record the time

during which water was not being withdrawn from the water heater

during the entire 24-hour period as stby,2.

5.2 Instantaneous Water Heaters.

5.2.1 Setting the Outlet Discharge Temperature. Initiate normal

operation of the water heater at the full input rating. Monitor the

discharge water temperature and set to a value of

135 deg.F5 deg.F (57.2 deg.C2.8 deg.C) in

accordance with the manufacturer's instructions. If the water heater

is not capable of providing this discharge temperature when the flow

rate is 3.000.25 gallons per minute

(11.40.95 liters per minute), then adjust the flow rate

as necessary to achieve the specified discharge water temperature.

Record the corresponding flow rate as Vmax.

If the instantaneous water heater incorporates a controller that

permits continuous burner or electric heating element operation at a

reduced input rate, adjust the flow rate as necessary to achieve a

discharge water temperature of 135 deg.F5 deg.F

(57.2 deg.C2.8 deg.C) while maintaining the minimum

input rate. Record the corresponding flow rate as Vmin. If an

outlet temperature of 135 deg.5 deg.F

(57.2 deg.C2.8 deg.C) cannot be achieved at the minimum

flow rate [[Page 15346]] permitted by the instantaneous water

heater, record the flow rate as Vmin and the corresponding

outlet temperature as Tmin.

25.2.2 Power Input Determination. Gas-fired and oil-fired

instantaneous water heaters shall have the burners adjusted to the

maximum firing rate specified by the manufacturer.

5.2.3 First Hour Rating Test for Instantaneous Water Heaters.

Establish normal water heater operation at the maximum input rate

with the discharge water temperature set in accordance with section

5.2.1. During the test, do not interrupt the electrical energy or

fossil fuel supplied to the water heater. During the one hour test,

either collect the withdrawn water for later measuring the total

mass removed, or alternatively, use a water meter to directly

measure the water volume removed.

Begin with the water flow rate temporarily discontinued. Record

the scale or water meter reading as appropriate. Initiate a draw and

record the corresponding time. Record the inlet and outlet water

temperatures beginning 15 seconds after the draw is initiated and at

every subsequent 5 second interval throughout the duration of the

draw. At the end of one hour terminate the draw. Determine the mass

of water withdrawn, MFHR, in pounds (kilograms), or the volume

of water withdrawn, VFHR, in gallons (liters) with an error no

greater than 2 percent.

5.2.4 24-Hour Simulated Use Test

5.2.4.1 Fixed Input Instantaneous Water Heaters. Establish

normal operation with the discharge water temperature and flow rate

set to values of 135 deg.F5 deg.F

(57.2 deg.C2.8 deg.C) and Vmax, respectively. With

no draw occurring, record the reading given by the gas meter, the

scale used for determining oil consumption, and/or the electrical

energy meter as appropriate. Begin the 24-hour simulated use test by

drawing an amount of water out of the water heater equivalent to

one-sixth of the daily hot water usage, 64.3 gallons (243 liters).

Record the time when this first draw is initiated and designated it

as an elapsed time, , of 0. At elapsed time intervals of

one, two, three, four, and five hours from = 0, initiate

additional draws removing an amount of water equivalent to one-sixth

of 64.3 gallons (243 liters), with the maximum allowable deviation

for any single draw being 0.5 gallons (2

liters). The quantity of water drawn during the sixth draw shall be

increased or decreased as necessary such that the total volume of

water withdrawn equals 64.31.0 gallons (2434

liters).

Measurements of the inlet and outlet water temperatures shall be

made beginning 15 seconds after the draw is initiated and at every 5

second interval throughout the duration of the draw. The arithmetic

mean of the hot water discharge temperature and the cold water inlet

temperature shall be determined for each draw. Record the scale used

to measure the mass of the withdrawn water or the water meter

reading, as appropriate, after each draw. At the end of the recovery

period following the first draw, determine and record the fossil

fuel or electrical energy consumed, Qr. Following the sixth

draw and subsequent recovery, allow the water heater to remain in

the standby mode until exactly 24 hours have elapsed since the start

of the test, i.e., since = 0. At 24 hours, record the

reading given by the gas meter, the scale used for determining oil

consumption, and/or the electrical energy meter as appropriate.

Determine the fossil fuel or electrical energy consumed during the

entire 24-hour simulated use test and designate the quantity as Q.

5.2.4.2 Variable Input Instantaneous Water Heaters. If the

instantaneous water heater incorporates a controller that permits

continuous operation at a reduced input rate, the first three draws

shall be conducted using the maximum flow rate, Vmax, while

removing an amount of water equivalent to one-sixth of 64.3 gallons

(243 liters), with the maximum allowable deviation for any one of

the three draws being 0.5 gallons (2 liters). The second

three draws shall be conducted at Vmin. If an outlet

temperature of 135 deg.F5 deg.F

(57.2 deg.C2.8 deg.C) could not be achieved at the

minimum flow rate permitted by the instantaneous water heater, the

last three draws should be lengthened such that the volume removed

is:

[GRAPHIC][TIFF OMITTED]TP23MR95.003

or

[GRAPHIC][TIFF OMITTED]TP23MR95.004

where the maximum allowable variation for any one of the three draws

is 0.5 gallons (2 liters). The quantity of water

withdrawn during the sixth draw shall be increased or decreased as

necessary such that the total volume of water withdrawn equals

(32.15+3 x V4,5,6)1.0 gallons

((121.7+3 x V4,5,6)3.8 liters).

Measurements of the inlet and outlet water temperatures shall be

made beginning 15 seconds after a draw is initiated and at every 5

second interval throughout the duration of the draw. Determine the

arithmetic mean of the hot water discharge temperature and the cold

water inlet temperature for each draw. Record the scale used to

measure the mass of the withdrawn water or the water meter reading,

as appropriate, after each draw. At the end of the recovery period

following the first draw, determine and record the fossil fuel or

electrical energy consumed, Qr,max. Likewise, record the

reading of the meter or scale used to measure fossil fuel or

electrical energy consumption prior to the fourth draw and at the

end of the recovery period following the fourth draw, and designate

the difference as Qr,min. Following the sixth draw and

subsequent recovery, allow the water heater to remain in the standby

mode until exactly 24 hours have elapsed since the start of the

test, i.e., since = 0. At 24 hours, record the reading

given by the gas meter, the scale used for determining oil

consumption, and/or the electrical energy meter, as appropriate.

Determine the fossil fuel or electrical energy consumed during the

entire 24-hour simulated use test and designate the quantity as Q.

6. Computations

6.1 Storage Tank and Heat Pump Water Heaters.

6.1.1 Storage Tank Capacity. The storage tank capacity is

computed using the following:

[GRAPHIC][TIFF OMITTED]TP23MR95.005

Where:

Vst=the storage capacity of the water heater, gal (L).

Wf=the weight of the storage tank when completely filled with

water, lbm (kg).

Wt=the (tare) weight of the storage tank when completely empty,

lbm (kg)

=the density of water use to fill the tank; evaluated based

on the temperature of the water, lbm/gal (kg/L).

6.1.2 First Hour Rating Computation. For water heaters where

the final draw was initiated at or prior to an elapsed time of one

hour, the first hour rating shall be computed using,

[GRAPHIC][TIFF OMITTED]TP23MR95.006

Where:

n=the number of draws that are completed during the first hour

rating test.

V*i=the volume of water removed during the ith draw of the

first hour rating test, gal (L).

[GRAPHIC][TIFF OMITTED]TP23MR95.097

Where:

M*i=the mass of water removed during the ith draw of the first

hour rating test, lbm (kg).

=the water density corresponding to the average outlet

temperature measured during the ith draw (T*del,i), lbm/

gal (kg/L).

For water heaters where a draw was not in progress at the

elapsed time of one hour and a final draw was imposed at the elapsed

time of one hour, the first hour rating shall be calculated using,

[GRAPHIC][TIFF OMITTED]TP23MR95.007

where n and V*i are the same quantities as defined above and,

T*del,n-1=the average water outlet temperature measured during

the (n-1)th draw of the first hour rating test, deg.F ( deg.C).

T*del,n=the average water outlet temperature measured during

the nth (final) draw of the first hour rating test, deg.F ( deg.C).

T*min,n-1=the minimum water outlet temperature measured during

the (n-1)th draw of the first hour rating test, deg.F ( deg.C).

[[Page 15347]] 6.1.3 Recovery Efficiency. The recovery

efficiency for gas, oil, and heat pump storage type water heaters is

computed as:

[GRAPHIC][TIFF OMITTED]TP23MR95.008

Where:

M1=total mass removed during the first draw of the 24-hour

simulated use test, lbm (kg).

=V1 x i

V1=total volume removed during the first draw of the 24-hour

simulated use test, gal (L).

1=density of the water as evaluated at the water

temperature at the point where the flow volume is measured,

lbm/gal (kg/L).

C1=specific heat of the withdrawn water as evaluated

at (Tdel,1 + Tin,1)/2 Btu/lbm deg.F (kJ/

kgK).

Tdel,1=average water outlet temperature measured during the

first draw of the 24-hour simulated use test, deg.F ( deg.C).

Tin,1=average water inlet temperature measured during the first

draw of the 24-hour simulated use test, deg.F ( deg.C).

Vst=measured volume of the storage tank, as determined in

section 6.1.1, gal (L).

2=density of stored hot water evaluated at (Tmax,

1+To)/2, lbm/gal (kg/L).

C2=specific heat of stored hot water evaluated at

(Tmax,1+To)/2, Btu/lbm deg.F (kJ/

kgK).

Tmax,1=maximum mean tank temperature recorded after cut-out

following the first draw of the 24-hour simulated use test, deg.F

( deg.C).

To=maximum mean tank temperature recorded prior to the first

draw of the 24-hour simulated use test, deg.F ( deg.C).

Qres,1=electrical energy used by the supplemental resistive

elements of a heat pump water heater during the first recovery of

the 24-hour simulated use test, Wh.

cmp,1=the total operating time of the compressor of a

heat pump water heater during the first recovery of the 24-hour

simulated use test, hr.

Qr=the total energy used by the water heater between cut-out

prior to the first draw and cutout following the first draw,

including auxiliary energy such as pilot lights, pumps, fans, etc.,

Btu (MJ). (electrical auxiliary energy shall be converted to thermal

energy using the following conversion: 1 Kwh=3412 Btu).

The recovery efficiency for electric water heaters with immersed

heating elements is assumed to be 98 percent.

6.1.4 Hourly Standby Losses. The hourly standby losses are

computed as

Where:

[GRAPHIC][TIFF OMITTED]TP23MR95.009

Qhr=the hourly standby energy losses of the water heater, Btu/

hr (kJ/hr).

Qstby=the total energy consumed by the water heater between the

time at which the maximum mean tank temperature is observed after

the sixth draw and the end of the 24-hour test period, Btu (kJ).

Vst=measured volume of the storage tank, as determined in

section 6.1.1, gal (L).

=density of stored hot water as evaluated at,

(T24+Tsu)/2, lbm/gal (kg/L).

C=specific heat of the stored water as evaluated at

(T24+Tsu)/2, Btu/lbm deg.F (kJ/

kg deg.C).

T24=the mean tank temperature at the end of the 24-hour

simulated use test, deg.F ( deg.C).

Tsu=maximum mean tank temperature observed after the sixth

draw, deg.F ( deg.C).

stby,1=elapsed time between the time at which the

maximum mean tank temperature is observed after the sixth draw and

the end of the 24-hour simulated use test, hr.

The standby heat loss coefficient for the tank is computed as:

[GRAPHIC][TIFF OMITTED]TP23MR95.010

Where:

Qhr=defined in section 6.1.4.

Tt,stby=overall average storage tank temperature between the

time when the maximum mean tank temperature is observed after the

sixth draw and the end of the 24-hour simulated use test, deg.F

( deg.C).

Ta,stby=overall average ambient temperature between the time

when the maximum mean tank temperature is observed after the sixth

draw and the end of the 24-hour simulated use test, deg.F ( deg.C).

UA=standby heat loss coefficient of the storage tank, Btu/

hr deg.F (kJ/hr deg.C).

6.1.5 Daily Water Heating Energy Consumption. The daily water

heating energy consumption, Qd is computed as:

[GRAPHIC][TIFF OMITTED]TP23MR95.011

Where:

Q=total energy used by the water heater during the 24-hour simulated

use test including auxiliary energy such as pilot lights, pumps,

fans, etc., Btu (kJ) (Electrical auxiliary energy shall be converted

to thermal energy using the following conversion: 1 kWh = 3412 Btu).

Vst=measured volume of the storage tank, as determined in

section 6.1.1, gal (L).

=density of the stored hot water as evaluated at

(T24+To)/2, lbm/gal (kg/L).

C=specific heat of the stored water as evaluated at

(T24+To)/2, Btu/lbm deg.F (kJ/

kg deg.C).

T24=mean tank temperature at the end of the 24-hour simulated

use test, deg.F ( deg.C).

To=mean tank temperature at the beginning of the 24-hour

simulated use test, recorded one minute before the first draw is

initiated, deg.F ( deg.C).

r=recovery efficiency of the hot water heater,

dimensionless.

6.1.6 Adjusted Daily Water Heating Energy Consumption. The

adjusted daily water heating energy consumption, Qda takes into

account that the temperature difference between the storage tank and

surrounding ambient temperature may not be the nominal value of

67.5 deg.F (135 deg.F-67.5 deg.F) or 37.5 deg.C (57.2 deg.C-

19.7 deg.C) due to the 10 deg.F (5.6 deg.C) allowable variation in

storage tank temperature, 1355 deg.F

(57.22.8 deg.C), and the 5 deg.F (2.8 deg.C) allowable

variation in surrounding ambient temperature 65 deg.F (18.3 deg.C)

to 70 deg.F (21.1 deg.C). The adjusted daily water heating energy

consumption is computed as:

[GRAPHIC][TIFF OMITTED]TP23MR95.012

Where:

Qda=the adjusted daily water heating energy consumption, in Btu

(kJ).

Tstby=the mean tank temperature during the total standby

portion, stby,2, of the 24-hour test, in deg.F

( deg.C).

Ta,stby=the average ambient temperature during the total

standby portion, stby,2, of the 24-hour test, in

deg.F ( deg.C).

UA=the standby heat loss coefficient for the storage tank, in Btu/

hr deg.F (kJ/hr deg.C).

stby,2=the number of hours during the 24-hour

simulated test when water was not being withdrawn from the water

heater.

A modification is also needed to take into account that the

temperature difference between the outlet water temperature and

supply water temperature may not be equivalent to the nominal value

of 77 deg.F (135 deg.F-58 deg.F) or 42.8 deg.C

(57.2 deg.C-14.4 deg.C). The following equations adjust the

experimental data to a nominal 77 deg.F (42.8 deg.C) temperature

rise.

The energy used to heat water, Btu/day (kJ/day) may be computed

as:

[GRAPHIC][TIFF OMITTED]TP23MR95.013

Where:

Mi=the mass withdrawn for the ith draw (i=1 to 6), in lbm

(kg).

Ci=the specific heat of water, in Btu/lbm deg.F

(kJ/kg deg.C). [[Page 15348]]

Tdel,i=the average water outlet temperature measured during the

ith draw (i=1 to 6), deg.F( deg.C).

Tin,i=the average water inlet temperature measured during the

ith draw (i=1 to 6), deg.F( deg.C).

r=as defined in section 6.1.3.

The energy required to heat the same quantity of water over a

77 deg.F (42.8 deg.C) temperature rise, Btu/day (kJ/day), is:

[GRAPHIC][TIFF OMITTED]TP23MR95.014

The difference between these two values is:

[GRAPHIC][TIFF OMITTED]TP23MR95.098

which must be added to the adjusted daily water heating energy

consumption value. Thus, the daily energy consumption value which

takes into account that the temperature difference between the

storage tank and ambient temperature may not be 67.5 deg.F

(37.5 deg.C) and the temperature rise across the storage tank may

not be 77 deg.F (42.8 deg.C) is:

[GRAPHIC][TIFF OMITTED]TP23MR95.015

6.1.7 Energy Factor. The energy factor, Ef, is computed

as:

[GRAPHIC][TIFF OMITTED]TP23MR95.016

or

[GRAPHIC][TIFF OMITTED]TP23MR95.017

Where:

Qdm=the modified daily water heating energy consumption as

computed in accordance with section 6.1.6, in Btu (kJ).

Mi=as defined in section 6.1.6.

Ci=as defined in section 6.1.6.

6.1.8 Annual Energy Consumption. The annual energy consumption

for storage type and heat pump water heaters is computed as:

[GRAPHIC][TIFF OMITTED]TP23MR95.018

Where:

Qdm=the modified daily energy consumption value, Btu/day (kJ/

day), and 365 is the number of days in a year.

6.2 Instantaneous Hot Water Heaters.

6.2.1 First Hour Rating Computation. Compute the first hour

rating as:

[GRAPHIC][TIFF OMITTED]TP23MR95.019

which may be expressed as:

[GRAPHIC][TIFF OMITTED]TP23MR95.020

Where:

MFHR=the mass removed during the one hour continuous draw, in

lbm (kg).

Tdel=the average delivery temperature, in deg.F ( deg.C).

Tin=the average inlet temperature, in deg.F ( deg.C).

=the density of water at the average delivery temperature,

in lbm/gal (kg/L).

If a water meter is used in lieu of a scale the first hour

rating is computed as:

[GRAPHIC][TIFF OMITTED]TP23MR95.021

Where:

V=the volume of water removed during the one hour continuous draw,

in gallons (liters).

Tdel=defined in section 6.2.1.

Tin=defined in section 6.2.1.

6.2.2 Recovery Efficiency

6.2.2.1 Fixed Input Instantaneous Water Heaters. The recovery

efficiency is computed as:

[GRAPHIC][TIFF OMITTED]TP23MR95.022

Where:

M1=the mass withdrawn during the first draw of the 24-hour

simulated use test, lbm (kg).

C1=the specific heat of water at the average

temperature (Tdel,1+Tin,1)/2, Btu/lbm deg.F

(kJ/kg deg.C).

Tdel,1=the average temperature for the first draw, deg.F

( deg.C).

Tin,1=the average inlet temperature for the first draw,

deg.F ( deg.C).

Qr=the total energy used by the water heater between cutout

prior to the first draw and cut-out following the first draw,

including auxiliary energy such as pilot lights, pumps, fans, etc.,

Btu (kJ).

6.2.2.2. Variable Input Instantaneous Water Heaters. For

instantaneous water heaters which have a variable firing rate, two

recovery efficiency values are computed, one at the maximum input

rate and one at the minimum input rate. The recovery efficiency used

in subsequent computations is taken as the average of these two

values. The maximum recovery efficiency is computed as:

[GRAPHIC][TIFF OMITTED]TP23MR95.023

Where:

M1=defined in section 6.2.2.1.

C1=defined in section 6.2.2.1.

Tdel,1=defined in section 6.2.2.1.

Tin,1=defined in section 6.2.2.1.

Qr,max=the total energy used by the water heater between cut-

out prior to the first draw and cut-out following the first draw,

including auxiliary energy such as pilot lights, Btu (kJ).

The minimum recovery efficiency is computed as:

[GRAPHIC][TIFF OMITTED]TP23MR95.024

Where:

M4=the mass withdrawn during the fourth draw, in lbm (kg).

C4=the specific heat of water, in Btu/

lbm deg.F (kJ/kg deg.C).

Tdel,4=the average delivery temperature for the fourth draw, in

deg.F ( deg.C).

Tin,4=the average inlet temperature for the fourth draw, in

deg.F ( deg.C).

Qr,min=the total energy consumed immediately prior to the

fourth draw and cut-out following the fourth draw, including

auxiliary energy such as pilot lights, in Btu (kJ).

The recovery efficiency is computed as:

[GRAPHIC][TIFF OMITTED]TP23MR95.025

Where:

r,max=defined in section 6.2.2.2.

r,min=defined in section 6.2.2.2.

6.2.3 Daily Water Heating Energy Consumption. The daily water

heating energy consumption, Qd is computed as:

Qd=Q

Where:

Q=the energy used by the flow actuated water heater during the 24-

hour simulated use test.

A modification is needed to take into account that the

temperature difference between the outlet water temperature and

supply water temperature may not be equivalent to the nominal value

of 77 deg.F (135 deg.F-58 deg.F) or 42.8 deg.C

(57.2 deg.C-14.4 deg.C). The following equations adjust the

experimental data to a nominal 77 deg.F (42.8 deg.C) temperature

rise.

The energy used to heat water may be computed as:

[GRAPHIC][TIFF OMITTED]TP23MR95.026

Where:

[[Page 15349]] Mi=the mass withdrawn during the ith draw, in

lbm (kg).

Ci=the specific heat of water of the ith draw, in Btu/

lbm deg.F(kJ/kg deg.C).

Tdel,i=the average delivery temperature of the ith draw, in

deg.F( deg.C).

Tin,i=the average inlet temperature of the ith draw, in

deg.F( deg.C).

r=defined in section 6.2.2.2.

The energy required to heat the same quantity of water over a

77 deg.F (42.8 deg.C) temperature rise is:

[GRAPHIC][TIFF OMITTED]TP23MR95.027

Where:

Mi=defined above.

Ci=defined above.

r=defined in above.

The difference between these two values is:

[GRAPHIC][TIFF OMITTED]TP23MR95.028

which must be added to the daily water heating energy consumption

value. Thus, the daily energy consumption value which takes into

account that the temperature rise across the storage tank may not be

77 deg.F (42.8 deg.C) is:

[GRAPHIC][TIFF OMITTED]TP23MR95.029

6.2.4 Energy Factor. The energy factor, Ef, is computed

as:

[GRAPHIC][TIFF OMITTED]TP23MR95.030

Where:

Qdm=the daily water heating energy consumption as computed in

accordance with Section 6.2.3, in Btu (kJ).

Mi=the mass associated with the ith draw, in lbm (kg).

Ci=the specific heat of water computed at a

temperature of (58 deg.F+135 deg.F)/2, Btu/lbm deg.F

[(14.4 deg.C+57.2 deg.C)/2, kJ/kg deg.C].

Tdel,i=the average delivery temperature of the ith draw, in

deg.F( deg.C).

Tin,i=the average inlet temperature of the ith draw, in

deg.F( deg.C).

6.2.5 Annual Energy Consumption. The annual energy consumption

for instantaneous type water heaters is computed as:

[GRAPHIC][TIFF OMITTED]TP23MR95.031

Where:

Qdm=the modified daily energy consumption, in Btu/day (kJ/day)

and 365 is the number of days within a year.

7. Ratings for Untested Models

In order to relieve the test burden to manufacturers who offer

water heaters which differ only in fuel type or power input, ratings

for untested models may be established in accordance with the

following procedures. In lieu of the following procedures a

manufacturer may elect to test the unit for which a rating is

sought.

7.1 Gas Water Heaters. Ratings obtained for gas water heaters

using natural gas can be used for an identical water heater which

utilizes propane gas if the input ratings are within 10 percent.

7.2 Electric Water Heaters

7.2.1 First Hour Rating. If an electric storage type water

heater is available with more than one input rating, the

manufacturer shall designate the standard input rating and the water

heater need only be tested with heating elements at the designated

standard input ratings. The first hour ratings for units having

power input rating less than the designated standard input rating

shall be assigned a first hour rating equivalent to the first draw

of the first hour rating for the electric water heater with the

standard input rating. For units having power inputs greater than

the designated standard input rating, the first hour rating shall be

equivalent to that measured for the water heater with the standard

input rating.

7.2.2 Energy Factor. The energy factor for identical electric

storage type water heaters, with the exception of heating element

wattage, may use the energy factor obtained during testing of the

water heater with the designated standard input rating.

5. Appendix I to subpart B of part 430 is revised to read as

follows:

Appendix I to Subpart B of Part 430--Uniform Test Method for Measuring

the Energy Consumption of Conventional Ranges, Conventional Cooking

Tops, Conventional Ovens, and Microwave Ovens

1. Definitions

1.1 Built-in means the product is supported by surrounding

cabinetry, walls, or other similar structures.

1.2 Drop-in means the product is supported by horizontal

surface cabinetry.

1.3 Forced convection means a mode of conventional oven

operation in which a fan is used to circulate the heated air within

the oven compartment during cooking.

1.4 Freestanding means the product is not supported by

surrounding cabinetry, walls, or other similar structures.

1.5 IEC 705 refers to the test standard published by the

International Electrotechnical Commission, entitled ``Method for

Measuring the Performance of Microwaves Ovens for Household and

Similar Purposes,'' Publication 705, Amendment 2-1993.

1.6 Normal nonoperating temperature means the temperature of

all areas of an appliance to be tested that is within 5 degrees

(2.8 deg.C) of the temperature that the identical areas of the same

basic model of the appliance would attain if it remained in the test

room for 24 hours while not operating with all oven doors closed and

with any gas pilot lights on and adjusted in accordance with

manufacturer's instructions.

1.7 Primary energy consumption means either the electrical

energy consumption of a conventional electric oven or the gas energy

consumption of a conventional gas oven.

1.8 Secondary energy consumption means any electrical energy

consumption, other than clock energy consumption, of a conventional

gas oven.

1.9 Standard cubic foot (L) of gas means that quantity of gas

that occupies 1 cubic foot (L) when saturated with water vapor at a

temperature of 60 deg.F (15.6 deg.C) and a pressure of 30 inches of

mercury (101.6 kPa) (density of mercury equals 13.595 grams per

cubic centimeter).

1.10 Thermocouple means a device consisting of two dissimilar

metals which are joined together and, with their associated wires,

are used to measure temperature by means of electromotive force.

2. Test Conditions

2.1 Installation. A free standing appliance shall be installed

with the back directly against, or as near as possible to, a

vertical wall which extends at least 1 foot above and on either side

of the appliance. There shall be no side walls. A drop-in, built-in

or wall-mounted appliance shall be installed in an enclosure in

accordance with the manufacturer's instructions. These appliances

are to be completely assembled with all handles, knobs, guards and

the like mounted in place. Any electric resistance heaters, gas

burners, baking racks, and baffles shall be in place in accordance

with the manufacturer's instructions; however, broiler pans are to

be removed from the oven's baking compartment.

Disconnect any electrical clock which uses energy continuously,

except for the microwave oven. Do not disconnect or modify the

circuit to any other electrical devices or features, except as

indicated in section 2.1.3.

2.1.1 Conventional electric ranges, ovens, and cooking tops.

These products shall be connected to an electrical supply circuit

with voltage as specified in section 2.2.1 with a watt-hour meter

installed in the circuit. The watt-hour meter shall be as described

in section 2.9.1.1.

2.1.2 Conventional gas ranges, ovens, and cooking tops. These

products shall be connected to a gas supply line with a gas meter

installed between the supply line and the appliance being tested,

according to manufacturer's specifications. The gas meter shall be

as described in section 2.9.2. Conventional gas ranges, ovens and

cooking tops with electrical ignition devices or other electrical

components shall be connected to an electrical supply circuit of

nameplate voltage with a watt-hour meter installed in the circuit.

The watt-hour meter shall be as described in section 2.9.1.1.

2.1.3 Microwave ovens. Install the microwave oven in accordance

with the manufacturer's instructions and connect to

[[Page 15350]] an electrical supply circuit with voltage as

specified in section 2.2.1. A watt meter and watt-hour meter shall

be installed in the circuit and shall be as described in section

2.9.1.1. and 2.9.1.2. If trial runs are needed to set the ``on''

time for the test, the test measurements are to be separated

according to section 4, Paragraph 12.6 of IEC 705.

2.2 Energy supply.

2.2.1 Electrical supply. Maintain the electrical supply to the

conventional range, conventional cooking top, and conventional oven

being tested at 240/120 volts except that basic models rated only at

208/120 volts shall be tested at that rating. Maintain the voltage

within 2 percent of the above specified voltages, except for the

microwave oven testing. Maintain the electrical supply to a

microwave oven at 120 volts 1 volt and at 60 hertz.

2.2.2 Gas supply.

2.2.2.1 Gas burner adjustments. Conventional gas ranges, ovens,

and cooking tops shall be tested with all of the gas burners

adjusted in accordance with the installation or operation

instructions provided by the manufacturer. In every case, the burner

must be adjusted with sufficient air flow to prevent a yellow flame

or a flame with yellow tips.

2.2.2.2 Natural gas. For testing convertible cooking appliances

or appliances which are designed to operate using only natural gas,

maintain the natural gas pressure immediately ahead of all controls

of the unit under test at 7 to 10 inches of water column (1743.6 to

2490.8 Pa). The regulator outlet pressure shall equal the

manufacturer's recommendation. The natural gas supplied should have

a heating value of approximately 1,025 Btu's per standard cubic foot

(38.2 kJ/L). The actual gross heating value, Hn, in Btu's per

standard cubic foot (kJ/L), for the natural gas to be used in the

test shall be obtained either from measurements made by the

manufacturer conducting the test using equipment that meet the

requirements described in section 2.9.4 or by the use of bottled

natural gas whose gross heating value is certified to be at least as

accurate a value that meet the requirements in section 2.9.4.

2.2.2.3 Propane. For testing convertible cooking appliances

with propane or for testing appliances which are designed to operate

using only LP-gas, maintain the propane pressure immediately ahead

of all controls of the unit under test at 11 to 13 inches of water

column (2740 to 3238 Pa). The regulator outlet pressure shall equal

the manufacturer's recommendation. The propane supplied should have

a heating value of approximately 2,500 Btu's per standard cubic foot

(93.15 kJ/L). The actual gross heating value, Hp, in Btu's per

standard cubic foot (kJ/L), for the propane to be used in the test

shall be obtained either from measurements made by the manufacturer

conducting the test using equipment that meet the requirements

described in section 2.9.4 or by the use of bottled propane whose

gross heating value is certified to be at least as accurate a value

that meet the requirements described in section 2.9.4.

2.2.2.4 Test gas. A basic model of a convertible cooking

appliance shall be tested with natural gas, but may also be tested

with propane. Any basic model of a conventional range, conventional

cooking top, or conventional oven which is designed to operate using

only natural gas as the energy source must be tested with natural

gas. Any basic model of a conventional range, conventional cooking

top, or conventional oven which is designed to operate using only LP

gas as the gas energy source must be tested with propane gas.

2.3 Air circulation. Maintain air circulation in the room

sufficient to secure a reasonably uniform temperature distribution,

but do not cause a direct draft on the unit under test.

2.4 Setting the conventional oven thermostat.

2.4.1 Conventional electric oven. Install a thermocouple

approximately in the center of the usable baking space. Provide a

temperature indicator system for measuring the oven's temperature

with an accuracy as indicated in section 2.9.3.2. If the oven

thermostat does not cycle on and off, adjust or determine the

conventional electric oven thermostat setting to provide an average

internal temperature which is 325 deg.5 deg.F

(162.8 deg.2.8 deg.C) higher than the room ambient air

temperature. If the oven thermostat operates by cycling on and off,

adjust or determine the conventional electric oven thermostat

setting to provide an average internal temperature which is

325 deg.5 deg.F (162.8 deg.2.8 deg.C) higher

than the room ambient air temperature. This shall be done by

measuring the maximum and minimum temperatures in any three

consecutive cut-off/cut-on actions of the electric resistance

heaters, excluding the initial cut-off/cut-on action, by the

thermostat after the temperature rise of 325 deg.5 deg.F

(162.8 deg.2.8 deg.C) has been attained by the

conventional electric oven. Remove the thermocouple after the

thermostat has been set.

2.4.2 Conventional gas oven. Install five parallel-connected

weighted thermocouples, one located at the center of the

conventional gas oven's usable baking space and the other four

equally spaced between the center and the corners of the

conventional gas oven on the diagonals of a horizontal plane through

the center of the conventional gas oven. Each weighted thermocouple

shall be constructed of a copper disc that is 1-inch (25.4 mm) in

diameter and \1/8\-inch (3.2 mm) thick. The two thermocouple wires

shall be located in two holes in the disc spaced \1/2\-inch (12.7

mm) apart, with each hole being located \1/4\-inch (6.4 mm) from the

center of the disc. Both thermocouple wires shall be silver-soldered

to the copper disc. Provide a temperature indicator system for

measuring the oven's temperature with an accuracy as indicated in

section 2.9.3.2. If the oven thermostat does not cycle on or off,

adjust or determine the conventional gas oven thermostat setting to

provide an average internal temperature which is

325 deg.5 deg.F (162.8 deg.2.8 deg.C) higher

than the room ambient air temperature. If the oven thermostat

operates by cycling on and off, adjust or determine the conventional

gas oven thermostat setting to provide an average internal

temperature which is 325 deg.5 deg.F

(162.82.8 deg.C) higher than the room ambient air

temperature. This shall be done by measuring the maximum and minimum

temperatures in any three consecutive cut-off/cut-on actions of the

gas burners, excluding the initial cut-off/cut-on action, by the

thermostat after the temperature rise of 325 deg.5 deg.F

(162.8 deg.2.8 deg.C) has been attained by the

conventional gas oven. Remove the thermocouple after the thermostat

has been set.

2.5 Ambient room air temperature. During the test, maintain an

ambient room air temperature, TR, of 77 deg.9 deg.F

(25 deg.5 deg.C) for conventional ovens and cooking

tops, or as indicated in section 4, Paragraph 12.4 of IEC 705 for

microwave ovens as measured at least 5 feet (1.5 m) and not more

than 8 feet (2.4 m) from the nearest surface of the unit under test

and approximately 3 feet (.9 m) above the floor. The temperature

shall be measured with a thermometer or temperature indicating

system with an accuracy as indicated in section 2.9.3.1.

2.6 Normal nonoperating temperature. All areas of the appliance

to be tested shall attain the normal nonoperating temperature, as

defined in section 1.6, before any testing begins. The equipment for

measuring the applicable normal nonoperating temperature shall be as

described in sections 2.9.3.1, 2.9.3.2, 2.9.3.4, and 2.9.3.5, as

applicable.

2.7 Test blocks for conventional oven and cooking top. The test

blocks shall be made of aluminum alloy No. 6061, with a specific

heat of 0.23 Btu/lb- deg.F (0.96 kJ/[kg deg.C]) and with any temper

that will give a coefficient of thermal conductivity of 2.6 to 2.8

BTU-in/in-ft\2\- deg.F (154.8 to 171.5 W/[m deg.C]). Each block

shall have a hole at its top. The hole shall be 0.08 inch (2.03 mm)

in diameter and 0.80 inch (20.3 mm) deep. The manufacturer

conducting the test may provide other means which will ensure that

the thermocouple junction is installed at this same position and

depth.

The bottom of each block shall be flat to within 0.002 inch

(0.051 mm) TIR (total indicator reading). Determine the actual

weight of each test block with a scale with an accuracy as indicated

in section 2.9.5.

2.7.1 Conventional oven test block. The test block for the

conventional oven, W1, shall be 6.250.05 inch

(158.81.3 mm) in diameter, approximately 2.8 inches (71

mm) high and shall weigh 8.50.1 lbs

(3.860.05 kg). The block shall be finished with an

anodic black coating which has a minimum thickness of 0.001 inch

(0.025 mm) or with a finish having the equivalent absorptivity.

2.7.2 Small test block for conventional cooking top. The small

test block, W2, shall be 6.250.05 inches

(158.81.3 mm) in diameter, approximately 2.8 inches (71

mm) high and shall weigh 8.50.1lbs (3.860.05

kg).

2.7.3 Large test block for conventional cooking top. The large

test block for the conventional cooking top, W3, shall be

90.05 inches (228.61.3 mm) in diameter,

approximately 3.0 inches (76 mm) high and shall weigh

190.1 lbs (8.620.05 kg).

2.7.4 Thermocouple installation. Install the thermocouple such

that the thermocouple junction (where the thermocouple contacts the

test block) is at the bottom of the hole provided in the test block

and that the thermocouple junction makes good thermal contact with

the aluminum block. If the test [[Page 15351]] blocks are to be

water cooled between tests the thermocouple hole should be sealed,

or other steps taken, to insure that the thermocouple hole is

completely dry at the start of the next test. Provide a temperature

indicator system for measuring the test block temperature with an

accuracy as indicated in section 2.9.3.3.

2.7.5 Initial test block temperature. Maintain the initial

temperature of the test blocks, TI, within 4 deg.F

(2.2 deg.C) of the ambient room air temperature as

specified in section 2.5. If the test block has been cooled (or

heated) to bring it to room temperature, allow the block to

stabilize for at least 2 minutes after removal from the cooling (or

heating) source, before measuring its initial temperature.

2.8 Microwave oven test load.

2.8.1 Test container. The test container shall be as specified

in section 4, Paragraph 12.2 of IEC 705.

2.8.2 Test water load. The test water load shall be as

specified in section 4, Paragraph 12.1 of IEC 705.

2.8.2.1 Test water load and test container temperature. Before

the start of the test, the oven and the test container shall be at

ambient temperature as specified in section 4, Paragraph 12.4 of IEC

705. The test water load shall be contained in a chiller (not the

test container) and maintained at 18 deg.1.8 deg.F

(10 deg.1 deg.C) below the ambient room temperature.

2.9 Instrumentation. Perform all test measurements using the

following instruments, as appropriate:

2.9.1 Electrical Measurements.

2.9.1.1 Watt-hour meter. The watt-hour meter for measuring the

electrical energy consumption of conventional ovens and cooking tops

shall have a resolution of at least 1 watt-hour (3.6 kJ) and a

maximum error no greater than 1.5 percent of the measured value. The

watt-hour meter for measuring the energy consumption of microwave

ovens shall have a resolution of at least 0.1 watt-hour (.36 kJ) and

a maximum error no greater than 1.5 percent of the measured value.

2.9.1.2 Wattmeter. The wattmeter used to measure the

conventional oven, conventional range, microwave/conventional range

clock power or the power input of the microwave shall have a

resolution of at least 0.2 watt (0.2 J/s) and a maximum error no

greater than 5 percent of the measured value.

2.9.2 Gas Measurements.

2.9.2.1 Positive displacement meters. The gas meter to be used

for measuring the gas consumed by the gas burners of the oven or

cooking top shall have a resolution of at least 0.01 cubic foot

(0.28 L) and a maximum error no greater than 1 percent of the

measured value. If a positive displacement gas meter is used for

measuring the gas consumed by the pilot lights, it shall have a

resolution of at least 0.01 cubic foot (0.28 L) and have a maximum

error no greater than 2 percent of the measured value.

2.9.2.2 Flow meter. If a gas flow meter is used for measuring

the gas consumed by the pilot lights, it shall be calibrated to have

a maximum error no greater than 1.5 percent of the measured value

and a resolution of at least 1 percent of the measured value.

2.9.3 Temperature measurement equipment.

2.9.3.1 Room temperature indicating system. The room

temperature indicating system shall be as specified in section 4,

Paragraph 12.3 of IEC 705.

2.9.3.2 Temperature indicator system for measuring conventional

oven temperature. The equipment for measuring the conventional oven

temperature shall have an error no greater than 4 deg.F

(2.2 deg.C) over the range of 65 deg. to 500 deg.F

(18 deg.C to 260 deg.C).

2.9.3.3 Temperature indicator system for measuring test block

temperature. The system shall have an error no greater than

2 deg.F (1.1 deg.C) when measuring specific

temperatures over the range of 65 deg. to 330 deg.F (18.3 deg.C to

165.6 deg.C). It shall also have an error no greater than

2 deg.F (1.1 deg.C) when measuring any

temperature difference up to 240 deg.F (115.6 deg.C) within the

above range.

2.9.3.4 Test load temperatures. The thermometer or other

temperature measuring instrument used to measure the test water load

temperature shall be as specified in section 4, Paragraph 12.3 of

IEC 705. Use only one thermometer or other temperature measuring

device throughout the entire test procedure.

2.9.3.5 Temperature indicator system for measuring surface

temperatures. The temperatures of an external surface of an

appliance shall be measured by means of a thermocouple in firm

contact with the surface. The temperature indicating system shall

have an error no greater than .45 deg.F

(0.25 deg.C) over the range 65 deg. to 90 deg.F

(18 deg.C to 32 deg.C).

2.9.4 Heating Value. The heating value of the natural gas or

propane shall be measured with an instrument and associated readout

device that has a maximum error no greater than .5% of the measured

value and a resolution of .2% or less of the full scale reading of

the indicator instrument. The heating value of natural gas or

propane must be corrected for local temperature and pressure

conditions.

2.9.5 Scale. The scale used for weighing the test blocks shall

have a maximum error no greater than 1 ounce (28.4 g). The scale

used for weighing the microwave oven test water load shall be as

specified in section four, paragraph 12.3 of IEC 705.

3. Test Methods and Measurements

3.1 Test methods.

3.1.1 Conventional oven. Perform a test by establishing the

testing conditions set forth in section 2, ``TEST CONDITIONS,'' of

this appendix, and adjust any pilot lights of a conventional gas

oven in accordance with the manufacturer's instructions and turn off

the gas flow to the conventional cooking top, if so equipped.

Before beginning the test, the conventional oven shall be at its

normal nonoperating temperature as defined in section 1.6 and

described in section 2.6. Set the conventional oven test block W1

approximately in the center of the usable baking space. If there is

a selector switch for selecting the mode of operation of the oven,

set it for normal baking. If an oven permits baking by either forced

convection by using a fan, or without forced convection, the oven is

to be tested in each of those two modes. If the oven thermostat does

not cycle on and off, adjust or determine the conventional electric

oven thermostat setting to provide an average internal temperature

which is 325 deg.5 deg.F

(162.8 deg.2.8 deg.C) air temperature. If the oven

thermostat operates by cycling on and off, adjust or determine the

conventional electric oven thermostat setting to provide an average

internal temperature which is 325 deg.5 deg.F

(162.8 deg.2.8 deg.C) higher than the room ambient air

temperature. The oven shall remain on for at least one complete

thermostat ``cut-off/cut-on'' of the electrical resistance heaters

or gas burners after the test block temperature has increased

234 deg.F (112.2 deg.C) above its initial temperature.

3.1.1.1 Self-cleaning operation of a conventional oven.

Establish the test conditions set forth in section 2, ``TEST

CONDITIONS,'' of this Appendix. Adjust any pilot lights of a

conventional gas oven in accordance with the manufacturer's

instructions and turn off the gas flow to the conventional cooking

top. The temperature of the conventional oven shall be its normal

nonoperating temperature as defined in section 1.6 and described in

section 2.6. Then set the conventional oven's self-cleaning process

in accordance with the manufacturer's instructions. If the self-

cleaning process is adjustable, use the average time recommended by

the manufacturer for a moderately soiled oven.

3.1.1.2 Continuously burning pilot lights of a conventional gas

oven. Establish the test conditions set forth in section 2, ``TEST

CONDITIONS,'' of this appendix. Adjust any pilot lights of a

conventional gas oven in accordance with the manufacturer's

instructions and turn off the gas flow to the conventional cooking

top. If a positive displacement gas meter is used the, test duration

shall be sufficient to measure a gas consumption which is at least

200 times the resolution of the gas meter.

3.1.2 Conventional cooking top. Establish the test conditions

set forth in section 2, ``TEST CONDITIONS,'' of this appendix.

Adjust any pilot lights of a conventional gas cooking top in

accordance with the manufacturer's instructions and turn off the gas

flow to the conventional oven(s), if so equipped. The temperature of

the conventional cooking top shall be its normal nonoperating

temperature as defined in section 1.6 and described in section 2.6.

Set the test block in the center of the surface unit under test. The

small test block, W2, shall be used on electric surface units

of 7 inches (178 mm) or less in diameter. The large test block,

W3, shall be used on electric surface units over 7 inches

(177.8 mm) in diameter and on all gas surface units. Turn on the

surface unit under test and set its energy input rate to the maximum

setting (100 percent). When the test block reaches 144 deg.F

(62.2 deg.C) above its initial test block temperature, immediately

reduce the energy input rate to 255 percent of the

maximum energy input rate. After 150.1 minutes at the

reduced energy setting, turn off the surface unit under test.

3.1.2.1 Continuously burning pilot lights of a conventional gas

cooking top. Establish the test conditions set forth in section 2,

``TEST CONDITIONS,'' of this appendix. [[Page 15352]] Adjust any

pilot lights of a conventional gas cooking top in accordance with

the manufacturer's instructions and turn off the gas flow to the

conventional oven(s). If a positive displacement gas meter is used,

the test duration shall be sufficient to measure a gas consumption

which is at least 200 times the resolution of the gas meter.

3.1.3 Microwave oven.

3.1.3.1 Microwave oven test energy or power output. Establish

the testing conditions set forth in section 2, ``TEST CONDITIONS,''

of this appendix. Follow the test procedure as specified in section

4, Paragraph 12.4 of IEC 705.

3.2 Test measurements.

3.2.1 Conventional oven test energy consumption. If the oven

thermostat controls the oven temperature without cycling on and off,

measure the energy consumed, EO, when the temperature of the

block reaches TO (TO is 234 deg.F (112.2 deg.C) above the

initial block temperature, TI). If the oven thermostat operates

by cycling on and off, make the following series of measurements:

Measure the block temperature, TA, and the energy consumed,

EA, at the end of the last ``ON'' period of the conventional

oven before the block reaches TO. Measure the block

temperature, TB, and the energy consumed, EB, at the

beginning of the next ``ON'' period. Measure the block temperature,

TC, and the energy consumed, EC, at the end of that ``ON''

period. Measure the block temperature, TD, and the energy

consumed, ED, at the beginning of the following ``ON'' period.

Energy measurements for EO, EA, EB, EC and

ED should be expressed in watt-hours for conventional electric

ovens or standard cubic feet (L) of gas for conventional gas ovens.

For a gas oven, measure in watt-hours any electrical energy,

EIO, consumed by an ignition device or other electrical

components required for the operation of a conventional gas oven

while heating the test block to TO.

3.2.1.1 Conventional oven average test energy consumption. If

the conventional oven permits baking by either forced convection or

without forced convection and the oven thermostat does not cycle on

and off, measure the energy consumed with the forced convection

mode, (EO)1, and without the forced convection mode,

(EO)2, when the temperature of the block reaches TO

(TO is 234 deg.F (112.2 deg.C) above the initial block

temperature, TI). If the conventional oven permits baking by

either forced convection or without forced convection and the oven

thermostat operates by cycling on and off, make the following series

of measurements with and without the forced convection mode: Measure

the block temperature, TA, and the energy consumed, EA, at

the end of the last ``ON'' period of the conventional oven before

the block reaches TO. Measure the block temperature, TB,

and the energy consumed, EB, at the beginning of the next

``ON'' period. Measure the block temperature, TC, and the

energy consumed, EC, at the end of that ``ON'' period. Measure

the block temperature, TD, and the energy consumed, ED, at

the beginning of the following ``ON'' period. Energy measurements

for EO, EA, EB, EC and ED should be

expressed in watt-hours for conventi