Use of Materials Bulletin 101 Used in the HUD Building Product Standards and Certification Program for Exterior Finish and Insulation Systems (EFIS)

Federal RegisterSep 14, 1995

Ask Donna

What actually matters in this document.

Text

[[Page 47840]]

DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT

Office of the Assistant Secretary for Housing--Federal Housing

Commissioner

24 CFR Part 200

[Docket FR-3365-F-02]

RIN 2502-AF84

Use of Materials Bulletin 101 Used in the HUD Building Product

Standards and Certification Program for Exterior Finish and Insulation

Systems (EFIS)

AGENCY: Office of the Assistant Secretary for Housing--Federal Housing

Commissioner, HUD.

ACTION: Final rule.

-----------------------------------------------------------------------

SUMMARY: This final rule adopts Use of Materials Bulletin (UM) No. 101

Exterior Finish and Insulation Systems (EFIS). The UM references

related national voluntary consensus standards, provides a labeling and

third party certification program to meet the appropriate national

voluntary standards, requires that a third-party inspection at the job

site be conducted, provides that additional information be included on

the label, tag, or mark that each manufacturer would affix to a

certified product, specifies the frequency with which products must be

tested in order to be acceptable to HUD, and requires an inspection

report regarding installation.

DATES: Effective date: Octoer 16, 1995. The incorporation by reference

of certain publications listed in the regulations is approved by the

Director of Federal Register as of August 16, 1995.

FOR FURTHER INFORMATION CONTACT: Leslie Breden, Office of Manufactured

Housing and Regulatory Functions, Standards and Products Branch,

Department of Housing and Urban Development, room 3214, L'Enfant Plaza,

490E, 451 Seventh Street SW., Mail Room B-133, Washington, DC 20410-

8000; telephone, voice: (202) 755-7440; (TDD) (202) 708-4594. (These

are not toll-free numbers.)

SUPPLEMENTARY INFORMATION: Pursuant to HUD's Building Product Standards

and Certification Program, which is authorized by Section 521 of the

National Housing Act, 12 U.S.C. 1735e, the Department issues Use of

Materials Bulletins (UM's). The UM's are issued to provide HUD

standards that establish minimum acceptable qualities for certain

materials and products to be used in properties subject to mortgages

insured by the Department. A UM is also used as a means of promulgating

a labeling and a certification program to assure that the products used

meet the appropriate standard.

On June 25, 1993 HUD published in the Federal Register (58 FR

34502) an interim rule which adopted Use of Materials Bulletin (UM) No.

101 Exterior Finish and Insulation systems (EFIS). The rule solicited

public comments. Eleven commenters sent comments.

One trade association objected to the elimination of gypsum

wallboard. It claimed other parts of the EFIS system fail and then

this, in turn, causes the wallboard to fail. The Department agrees that

when the gypsum wallboard fails, it is usually the result of a break in

the exterior envelope allowing moisture to enter the EIFS system.

However, once water gets inside the EFIS system, the paper over the

gypsum core debonds resulting in a catastrophic failure of the gypsum

wallboard and a loss of the cladding's securement to the building

structure. Therefore, the Department has referenced a standard for

fiber cement board which remains secure even when wet.

Similarly, two manufacturers desire to use a sheathing material

that does not comply with American Society for Testing and Materials C-

1186. The Department contends that the sheathing should last as long as

the mortgage and since the manufacturer will only guarantee this

product for 5 years, it was determined that 5 years is not a long

enough time for one to have confidence in the integrity of the whole

EFIS system.

One inspection agency suggested that other variables, such as

temperature and the esthetic design, should be included in the UM. The

Department feels there is a wide range of possible variables in EFIS

systems and it was not possible at this time to examine all of these

items, but the Department will continue to examine these and other

parameters to determine if they have a significant effect on the

failure of the EFIS system.

Another trade association suggested that nationally recognized

standards such as, Exterior Insulation Manufacturers Association (EIMA)

and American Society for Testing and Materials (ASTM) Standards, be

referenced in lieu of Military and Federal standards. The Department

agrees and has referenced EIMA and ASTM standards wherever possible.

One testing laboratory suggested a new water absorption test for

polystyrene foam. The Department will add this test to a future

revision of UM 101 when it is adopted by ASTM.

One manufacturer wants a wider definition of fiber cement board

than that defined by ASTM C 1186-91. The Department feels that this

would require a revision to the ASTM standard. Therefore, the

Department has recommended that the appropriate ASTM committee be

contacted for revising the existing standard.

Finally, a third party inspection agency suggested that ASTM C 578-

92 be referenced instead of ASTM C 578-91. UM 101 has been changed to

incorporate UM 71 which contains ASTM C 578-92. It also wants a better

definition of hail damage. To date, the Department has not been able to

exactly quantify what is meant by hail damage. It is investigating

establishing a knowledgeable review by peer inspectors for determining

the definition of hail damage.

The Department has evaluated the technical standards for exterior

finish and insulation systems and plans to adopt these standards by

incorporating them into the UM by reference. The UM's adoption would

also augment the labeling requirements of 24 CFR 200.935(d)(6).

The text of the UM is not being produced in the final rule because

the substance is embodied in a new section of 24 CFR 200.946 set forth

below. However, copies of the UM are available for public inspection

during regular business hours in the Office of Manufactured Housing and

Regulatory Functions, Standards and Products Branch, Department of

Housing and Urban Development, room 3214 L'Enfant Plaza, 490E, Mail

Room B-133, Washington, DC, 20410-8000, and in the Office of the Rules

Docket Clerk, Office of General Counsel, Room 10276, Department of

Housing and Urban Development, 451 Seventh Street SW., Washington, DC

20410-0500.

National Environmental Policy Act

A Finding of No Significant Impact with respect to the environment

has been made in accordance with HUD regulations at 24 CFR Part 50,

which implement Section 102 (2)(c), of the National Environment Policy

Act of 1969, 42 U.S.C. 4321 et. seq. The Finding of No Significant

Impact is available for public inspection between 7:30 a.m. and 5:30

p.m. weekdays in the Office of the Rules Docket Clerk at the above

address.

Regulatory Flexibility Act

In accordance with 5 U.S.C. 605(b) (the Regulatory Flexibility

Act), the Undersigned hereby certifies that this rule would not have a

significant economic impact on a substantial

[[Page 47841]]

number of small entities. This UM would adopt standards that are

nationally recognized throughout the affected industry and will not

create a burden on manufacturers.

Family Impact

The General Counsel, as the Designated Official under Executive

Order 12606, The Family, has determined that this final rule does not

have potential for significant impact on family formation, maintenance,

and general well-being; therefore, it is not subject to review under

the order.

Federalism

The General Counsel, as the Designated Official under Section 6(a)

of Executive Order 12612, Federalism, has determined that the policies

contained in this final rule would not have substantial direct effect

on states or their political subdivisions, or the relationship between

the Federal government and the states, or on the distribution of power

and responsibilities among the various levels of government. As a

result, the final rule is not subject to review under the order.

Incorporation by Reference

These standards have been approved by the Director of the Federal

Register for incorporation by reference in accordance with 5 U.S.C.

552(a) and 1 CFR 51. Copies of the standards may be obtained from the

American Society for Testing and Materials (ASTM), 1916 Race Street,

Philadelphia, Pennsylvania 19103; the Council of American Building

Officials, 5203 Leesburg Pike, Falls Church, Virginia 22041; & the

Exterior Insulation Manufacturers Association, 2759 State Road 580,

Suite 112, Clearwater, Florida 34621.

Copies of the standards are also available for inspection at the

Office of Manufactured Housing and Regulatory Functions, Standards and

Products Branch, Department of Housing and Urban Development, Room

3214, L'Enfant Plaza, 490E, Mail Room B-133, Washington, DC 20410-8000,

and at the Office of the Federal Register, 800 North Capital Street,

NW, Suite 700, Washington, DC.

List of Subjects in 24 CFR Part 200

Administrative Practice and Procedures, Claims, Equal Employment

Opportunity, Fair Housing, Housing Standards, Incorporation by

Reference, Lead Poisoning, Loan Programs--Housing and Community

Development, Minimum Property Standards, Mortgage Insurance,

Organization and Functions (Government agencies), Penalties, Reporting

and Recordkeeping Requirements, Social Security, Unemployment

Compensation, Wages.

Accordingly, 24 CFR Part 200 is amended as follows:

PART 200--INTRODUCTION

1. The authority citation for 24 CFR 200 continues to read as

follows:

Authority: 12 U.S.C. 1701-1715z-(18); 42 U.S.C. 1436a and

3535(d).

2. Section 200.946 is revised to read as follows:

Sec. 200.946 Building product standards and certification program for

exterior finish and insulation systems, use of Materials Bulletin UM

101.

(a) Applicable standards: (1) All Exterior Finish and Insulation

Systems shall be designed, manufactured, and tested in compliance with

the following standards:

(i) ASCE 7-93, American Society of Civil Engineers--Minimum Design

Loads for Buildings and Other Structures.

(ii) ASTM C 150-94 Standard Specification for Portland Cement.

(iii) ASTM C 920-87 Standard Specification for Elastomeric Joint

Sealants.

(iv) ASTM C-1186-91 Standard Specification for Flat Non-Asbestos

Fiber-Cement Sheets.

(v) ASTM D 579-90 Standard Specification for Greige Woven Glass

Fabrics.

(vi) ASTM-D 3273-86--(Reapproved 1991) Standard Test Method for

Resistance to Growth of Mold on the Surface of Interior Coatings in an

Environmental Chamber.

(vii) ASTM E 330-90 Standard Test Method for Structural Performance

of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air

Pressure Difference.

(viii) ASTM E 695-79 (Reapproved 1991), Standard Method of

Measuring Relative Resistance of Wall, Floor, and Roof Construction to

Impact Loading.

(ix) ASTM G 26-93 Standard Practice for Operating Light-Exposure

Apparatus (Xenon-Arc Type) With and Without Water for Exposure of

Nonmetallic Materials.

(x) Council of American Building Officials, Model Energy Code, 1993

Edition.

(xi) EIMA Test Method 101.01-95 (modified ASTM C67-91) Standard

Test Method for Freeze/Thaw Resistance of Exterior Insulation and

Finish Systems (EIFS), Class PB.

(xii) EIMA Test Method 101.02-95 (modified ASTM E331-91)--Standard

Test Method for Resistance to Water Penetration of Exterior Insulation

and Finish Systems (EIFS), Class PB.

(xiii) EIMA Test Method 101.03-95 (modified ASTM C297-91)--Standard

Test Method for Determining the Tensile Adhesion Strength of an

Exterior Insulation and Finish System (EIFS), Class PB.

(xiv) EIMA Test Method 105.01-95--Standard Test Method for Alkali

Resistance of Glass Fiber Reinforcing Mesh for Use in Exterior

Insulation and Finish Systems (EIFS), Class PB.

(xv) European Agreement Union Technical Committee--June 88--UEAtc

Directives for the Assessment of External Insulation System for Walls

(Expanded Polystyrene Insulation Faced with a Thin Rendering) Section

3.3.3.3.

(2) These standards have been approved by the Director of the

Federal Register for incorporation by reference in accordance with 5

U.S.C. 552(a) and 1 CFR part 51. They are available from:

(i) American Society Civil Engineers (ASCE) 345 East 47th Street,

New York, NY 10017.

(ii) American Society for Testing and Materials (ASTM), 1916 Race

Street, Philadelphia, Pennsylvania 19103;

(iii) Council of American Building Officials, 5203 Leesburg Pike,

Falls Church, Virginia 22041;

(iv) EAUTC Centre Scientifique ET Technique Du Batiment (CSTB), 84

Avenue Jesu Jaures, B.P. 02-77421 Marne-LA-Valee Cedex 2, Paris,

France.

(v) Exterior Insulation Manufacturers Association (EIMA), 2759

State Road 580, Suite 112, Clearwater, Florida 34621-3350.

(3) The standards are available also for inspection at the Office

of Manufactured Housing and Regulatory Functions, Standards and

Products Branch, Department of Housing and Urban Development, room

3214, L'Enfant Plaza, 490E, Mail Room B-133, Washington, DC 20410-8000,

and at the Office of the Federal Register, 800 North Capitol Street,

NW., Suite 700, Washington, DC.

(b) Labeling. Under the procedures as set forth in

Sec. 200.935(d)(6), concerning labeling of a product, the

administrator's validation mark and the manufacturer's certification of

compliance with the applied standard is required to be on the

certification label issued by the administrator to the manufacturers.

In the case of exterior wall insulation and finish systems, the

certification label containing the administrator's mark shall be

permanently affixed on the package or container of base and finish

coating materials. Further, additional information shall be included on

the certification label or mark:

[[Page 47842]]

(1) Manufacturer's name.

(2) Manufacturer's statement of conformance with UM 101.

(c) The Administrator shall visit the manufacturer's or sponsor's

facility every 6 months, to assure that the initially accepted quality

assurance procedures are being followed. At least every four years, the

Administrator also shall have the exterior wall insulation and finish

systems tested in an approved laboratory to assure that the original

performance is maintained.

(d) The administrator's (or administration-accepted inspection

agency) inspection of EFIS system installation of 5000 sq. ft. or more,

shall be made during and upon completion of the construction. Reports

of the inspection shall be made to the owner. These reports shall

state:

(1) The coverage of the finish coat per square foot for a given

volume of finish.

(2) The minimum thickness of the base and finish coatings.

(3) The fiberglass mesh is installed properly around joints and

insulation. All penetrations, including windows, flashing, etc., are

sealed; and there is a caulk and sealant continuity evaluation; and

(4) There is a caulk and sealant continuity evaluation with special

concerns on maintenance.

(d) The manufacturer shall warrant their exterior wall insulation

and finish system, including any caulks and sealants, for twenty years

against faulty performance. The warranty shall include correction of

delamination, chipping, denting, peeling, blistering, flaking, bulging,

unsightly discoloration, or other serious deterioration of the system

such as the intrusion of water through the wall or structural failure

of the system's surface materials. Should any of these defects occur,

the manufacturer shall make a pro-rata allowance for replacement or pay

the owner the amount of the allowance. The manufacturer shall not be

liable for damages or defects resulting from misuse, natural

catastrophes, or other causes beyond the control of the manufacturer.

The contractor shall provide a statement to the owner that the product

has been installed in compliance with HUD requirements and that the

manufacturer's warranty does not relieve the builder, in any way, of

responsibility under the terms of the Builder's Warranty required by

the National Housing Act, or under any other housing program.

Dated: May 11, 1995.

Nicolas P. Retsinas,

Assistant Secretary for Housing-Federal Housing Commissioner.

[FR Doc. 95-22824 Filed 9-13-95; 8:45 am]

BILLING CODE 4210-27-P