National Emission Standards for Hazardous Air Pollutants: Halogenated Solvent Cleaning

Federal RegisterDec 2, 1994

Ask Donna

What actually matters in this document.

Text

ENVIRONMENTAL PROTECTION AGENCY

40 CFR Parts 9 and 63

[AD-FRL-5111-3]

RIN 2060-AC31

National Emission Standards for Hazardous Air Pollutants:

Halogenated Solvent Cleaning

AGENCY: Environmental Protection Agency (EPA).

ACTION: Final rule and test method.

-----------------------------------------------------------------------

SUMMARY: This final rule promulgates national emission standards for

hazardous air pollutants for halogenated solvent cleaners. These

standards implement section 112 of the Clean Air Act (Act) and are

based on the Administrator's determination that halogenated solvent

cleaning machines emit halogenated organic chemicals identified in the

Act list of 189 hazardous air pollutants (HAP). The halogenated solvent

cleaner NESHAP requires batch vapor solvent cleaning machines and in-

line solvent cleaning machines to meet emission standards reflecting

the application of the maximum achievable control technology for major

and area sources; area source batch cold cleaning machines are required

to achieve generally available control technology. The rule regulates

the emissions of the following halogenated HAP solvents: methylene

chloride (MC), perchloroethylene (PCE), trichloroethylene (TCE), 1,1,1-

trichloroethane (TCA), carbon tetrachloride (CT), and chloroform (C).

The EPA is also finalizing Method 307 with the standard. This

method can be used to demonstrate compliance with the idling standard.

EFFECTIVE DATE: December 2, 1994. See Supplementary Information section

concerning judicial review.

ADDRESSES: Background Information Document. The background information

document (BID) for the promulgated standards may be obtained from the

U.S. EPA Library (MD-35), Research Triangle Park, North Carolina 27711,

telephone number (919) 541-2777. Please refer to ``National Emission

Standards for Hazardous Air Pollutants, Halogenated Solvent Cleaning--

Background Information for Final Standards,'' EPA No. 453/R-94-071. The

BID contains: (1) a summary of all the public comments made on the

proposed standards and the Administrator's response to the comments;

and (2) a summary of the changes made to the standards since proposal.

A reasonable fee may be charged for copying.

Docket. A docket, No. A-92-39, containing information considered by

the EPA in development of the promulgated standards, is available for

public inspection between 8:00 a.m. and 4:00 p.m., Monday through

Friday, at the following address: U.S. Environmental Protection Agency,

Air and Radiation Docket and Information Center (formerly known as the

Air Docket) (MC-6102), 401 M Street SW., Washington, DC 20460 [phone:

(202) 260-7548]. The docket is located at the above address in Room M-

1500, Waterside Mall (ground floor). A reasonable fee may be charged

for copying.

FOR FURTHER INFORMATION CONTACT: For information concerning the final

standard, contact Mr. Paul Almodovar, Coatings and Consumer Products

Group, Emission Standards Division (MD-13), U.S. Environmental

Protection Agency, Research Triangle Park, North Carolina, 27711,

telephone number (919) 541-0283.

SUPPLEMENTARY INFORMATION: National emission standards for hazardous

air pollutants (NESHAP) for halogenated solvent cleaners were proposed

in the Federal Register on November 29, 1993 (58 FR 62566). This

Federal Register action announces the EPA's final decisions on the

rule. Under section 307(b)(1) of the Act, judicial review of the NESHAP

is available only by the filing of a petition for review in the U.S.

Court of Appeals for the District of Columbia Circuit within 60 days of

today's publication of this rule. Under section 307(b)(2) of the Act,

the requirements that are the subject of today's notice may not be

challenged later in civil or criminal proceedings brought by the EPA to

enforce these requirements.

I. The Standards

National emission standards for major sources of hazardous air

pollutants established under section 112 of the Act reflect:

``* * * the maximum degree of reduction in emissions of the HAP

* * * that the Administrator, taking into consideration the cost of

achieving such emission reduction, and any nonair quality health and

environmental impacts and energy requirements, determine is

achievable for new or existing sources in the category or

subcategory to which such emission standards applies * * *'' (the

Act section 112(d)(2)).

Area sources are regulated with a MACT standard, unless there is

justification for regulating them under GACT.

The promulgated standard includes multiple alternatives to allow

owners or operators maximum compliance flexibility. These alternatives

include an equipment standard, in conjunction with work practice

requirements, and an alternative overall solvent emissions standard.

The idling emission limit and the alternative overall solvent emission

standard are not available to owners or operators of batch cold

cleaning machines.

If an owner or operator of a batch vapor or in-line cleaning

machine elects to comply with the equipment standard, they must install

one of the control combinations listed in the regulation, use an

automated parts handling system to process all parts, and follow

multiple work practices. As an alternative to selecting one of the

equipment control combinations listed in the regulation, an owner or

operator may demonstrate that the batch vapor or in-line cleaning

machine can meet the idling mode emission limit specified in the

standards. In addition to maintaining this idling mode emission limit,

the owner or operator of a batch vapor or in-line solvent cleaning

machine must use an automated parts handling system to process all

parts and comply with the work practice standards. A third alternative

for complying with these standards is to comply with the overall

solvent emissions limit. An owner or operator complying with the

overall solvent emissions limit is required to ensure that the

emissions from each solvent cleaning machine are less than or equal to

the solvent emission levels specified in the standard. Under this

alternative standard, an owner or operator is not required to use an

automated parts handling system or to comply with the work practice

standards.

The batch cold cleaning machine standard is an equipment standard.

However, those owners or operators choosing the equipment options

without the water layer must also comply with work practice

requirements. There is no idling standard or overall solvent emissions

standard for batch cold cleaning machines. Batch cold cleaning machines

located at nonmajor sources are exempt from title V permit

requirements.

Section 114(a)(3) of the amended CAA requires enhanced monitoring

and compliance certification of all major stationary sources. The

annual compliance certifications certify whether compliance has been

continuous or intermittent. Enhanced monitoring shall be capable of

detecting deviations from each applicable emission limit or standard

with sufficient representativeness, accuracy, precision, reliability,

frequency and timeliness to determine if compliance is continuous

during a reporting period. The monitoring in this regulation satisfies

the requirements of enhanced monitoring.

II. Summary of Impacts

These standards will reduce nationwide emissions of hazardous air

pollutants (HAP) from halogenated solvent cleaning machines by 77,400

Mg/yr (85,300 tons per year), or 63 percent by 1997 compared to the

emissions that would result in the absence of the standards. No adverse

secondary air impacts, water or solid waste impacts are anticipated

from the promulgation of these standards.

The national annual energy usage due to the installation of the

required control devices is expected to increase from 12.9 million KWH/

yr to 66.9 million KWH/yr, which is equivalent to approximately 29.3

thousand barrels of oil. These estimates do not include energy savings

from reduced solvent use.

The implementation of this regulation is expected to result in an

overall annual national net savings of $19 million. This includes a net

annualized savings from installation of control devices of $30.5

million and a total monitoring, reporting, and recordkeeping costs of

$11.6 million. These savings will come from the significant decrease in

solvent emissions and, therefore, solvent consumption, which outweigh

the overall cost of air pollution control equipment and monitoring and

recordkeeping costs.

The economic impact analysis done at proposal showed that the

economic impacts from the proposed standard would be insignificant. The

economic impact analysis has not been revised for promulgation because

the changes in costs are not expected to have any effect on the results

of the analysis. While the estimated annual costs for the regulation

have increased since proposal, there are still cost savings for most

affected entities. Only entities with small or medium-sized cleaning

machines will not have cost savings, and the costs for the selected

regulatory alternatives for these entities have changed very little

since proposal. Since those entities that do not have cost savings were

the only ones analyzed in the proposal, and these costs have changed

little, the results from the economic impact analysis at proposal

should still hold for promulgation.

III. Significant Changes to the Proposed Standards

A. Public Participation

Prior to proposal of the standards, interested parties were advised

by public notice in the Federal Register (57 FR 46854), of a meeting of

the National Air Pollution Control Techniques Advisory Committee to

discuss the halogenated solvent cleaner source recommended for

proposal. This meeting was held on November 17 and 18, 1992. The

meeting was open to the public and each attendee was given an

opportunity to comment on the standards recommended for proposal.

The standards were proposed and published in the Federal Register

on November 29, 1993 (58 FR 62566). The preamble to the proposed

standards discussed the availability of the BID, which described the

regulatory alternatives considered and the impacts of those

alternatives. Public comments were solicited at the time of proposal,

and copies of the BID were distributed to interested parties.

To provide interested persons the opportunity for oral presentation

of data, views, or arguments concerning the proposed standards, a

public hearing was offered at proposal; however, one was not requested.

The public comment period was from November 29, 1993 to January 28,

1994. Fifty-seven comment letters were received. The comments have been

carefully considered, and changes have been made in the proposed

standards when determined by the Administrator to be appropriate.

B. Comments on the Proposed Standards

Comments on the proposed standards were received from 57 commenters

composed mainly of States, solvent cleaning machine users, solvent

cleaning machine vendors, industry and industry trade associations. A

detailed discussion of these comments and responses can be found in the

promulgation BID, which is referenced in the ADDRESSES section of this

preamble. The summary of comments and response in the BID serve as the

basis for the revisions that have been made to the standards between

proposal and promulgation. Most of the comment letters contained

multiple comments. The comments have been divided into the following

areas:

Selection of pollutants and source categories for

regulation.

Emission control options.

Regulatory alternatives.

Benefits analysis/economics.

Equipment, idling, work practice and overall solvent

emission limit standards.

Modification and reconstruction considerations.

Monitoring requirements.

Recordkeeping and reporting requirements.

Operating permit program.

Clarifications.

Miscellaneous.

C. Significant Changes

Several changes have been made since the proposal of these

standards. The majority of the changes have been made to clarify

portions of the rule that were unclear to the commenters. Other changes

include adding additional control combinations and an equation that

allows cleaning machines that do not have a solvent vapor/air interface

area to comply with the standard by meeting a solvent emission limit

based on cleaning capacity. A summary of the major changes is presented

below.

(1) Several comments were made about the complexity of the rule,

with many commenters offering suggested changes to clarify different

sections. Many of these recommendations have been incorporated into the

final rule. For example, the standards for batch cold cleaning machines

have been moved to a separate section, the operator test has been

included as appendix B, and a table summarizing the applicability of

the General Provisions to this rule has been included in appendix C.

(2) The applicability section of the rule has been clarified to

ensure that the standard regulates only those solvents originally

intended for inclusion; namely, MC, PCE, TCE, TCA, CT, and C. Several

commenters were concerned that, as proposed, the rule could be

interpreted to regulate non-halogenated solvents contaminated by trace

amounts of halogenated solvent. The EPA never intended for these

solvents to be included in these standards.

(3) An equation and table have been added to allow solvent cleaning

machines that do not have a solvent vapor/air interface area to comply

with these standards. Several new cleaning machines are currently being

developed by industry that cannot install the equipment control devices

included in this final rule, do not have an idling mode, and do not

have a solvent vapor/air interface area to relate to the solvent

emission limit. The equation and table in the rule allow owners or

operators of halogenated solvent cleaning machines without a solvent

vapor/air interface area to comply with the standard by meeting an

overall solvent emissions limit based on cleaning capacity that is

equivalent to the overall solvent emissions limit for machines with a

solvent vapor/air interface.

(4) The list of equipment combinations has been modified to remove

overlapping controls and to add carbon adsorbers to the control

combinations.

There are multiple control combinations available for meeting the

rule, many of which are pollution prevention measures. Many of these

options also reduce worker exposure. However, some sources may rely on

lip exhausts instead in order to meet OSHA requirements. Use of a lip

exhaust without any controls, while reducing worker exposure on the one

hand, would dramatically increase the overall emissions to air. Thus,

if lip exhausts are used on solvent cleaning machines, the rule

requires carbon adsorption controls (which have been added explicitly

as a control option in the final rule). Although the lip exhaust-carbon

adsorption combination reduces worker exposure and overall emissions to

air, it may impose additional cost and burden on sources as well as on

the environment for a number of reasons. First, carbon adsorption units

are generally more expensive than other controls listed in the options.

Second, these units may present cross-media impacts such as effluent

discharges if not properly operated and maintained, and spent carbon

beds that have to be disposed of as hazardous waste. Thus, when making

decisions about what controls to install on halogenated solvent

cleaning machines to meet the requirements of this rule, all of these

factors should be weighed and pollution prevention measures are

encouraged wherever possible.

The EPA acknowledges that data show little additional benefit is

achieved by the use of a working-mode cover in the presence of reduced

room draft. Therefore, these controls are no longer included in the

same control combination.

(5) Some changes have also been made to the compliance and

reporting schedules. The initial notification report deadline for

existing sources has been extended from 90 to 270 days after

promulgation. This overrides the 120 day deadline in the final part 63

General Provisions. This was done to allow more time for the delegation

of this rule to the States and to allow more time to process the

reports from the large number of facilities affected by this rule. The

initial statement of compliance report deadline for new and existing

sources has been extended from 30 days to 150 days after the compliance

date to allow time for owners or operators to determine compliance with

the 3-month rolling average emission limit. The compliance time for

existing sources has been extended from 2 to 3 years. This extension

has been provided to allow sources the maximum flexibility in complying

with these standards, including allowing time to consider alternative

cleaning technologies. This change is consistent with the General

Provisions (Sec. 63.6(b)(3)). The exceedance report schedule has been

changed to include a biannual exceedance report if there is not an

exceedance. This change is consistent with the General Provisions

(Sec. 63.10(e)). Exceedance reports must still be submitted quarterly

if there is an exceedance.

(6) Several commenters stated that the rule was complex and

difficult to understand. They stated that additional guidance should be

provided, particularly for small businesses. The EPA agrees that

guidance would be helpful and has developed a brochure summarizing the

rule, and will be developing a guidance manual that is scheduled for

publication in January 1995. This guidance manual includes a detailed

summary of the rule, example forms that can be used for reporting and

recordkeeping, and additional assistance for evaluating alternative

cleaning technologies.

(7) Several commenters recommended that the EPA reduce the

monitoring frequency of the emission control equipment. The EPA

evaluated the monitoring frequencies and has added a provision to the

final rule that allows the hoist monitoring frequency to decrease from

monthly to quarterly if, the owner or operator has operated the hoist

for one year without an exceedance in the hoist speed. The EPA has also

changed the reduced room draft (RRD) monitoring frequency from weekly

to quarterly with weekly monitoring of the parameters used to obtain

the RRD.

(8) Several comments were received on the batch cold cleaning

machine equipment requirement provisions. A number of commenters

reported the use of TCA, MC, and TCE in noncarburetor batch cold

cleaning machine operations. The commenters stated that the proposed

water layer control option was not always possible for these cleaning

machines, particularly when TCA or TCE solvents are used. In order to

address this issue, alternative control equipment options were added to

the final rule to allow for the use of an increased freeboard ratio and

cover, or remote-reservoir and cover, in lieu of a water layer and

cover. An owner or operator complying with these alternative options

must also comply with work practice requirements. The final rule also

allows an owner or operator of a batch cold cleaning machine to use

alternative control equipment, if demonstrated to be equivalent to the

equipment requirements cited in the final rule and approved by the

Administrator.

IV. Administrative Requirements

A. Docket

The docket is an organized and complete file of all the information

considered by the EPA in the development of this rulemaking. The docket

is a dynamic file, since material is added throughout the rulemaking

development. The docketing system is intended to allow members of the

public and industries involved to readily identify and locate documents

so that they can effectively participate in the rulemaking process.

Along with the statement of basis and purpose of the proposed and

promulgated standards and the EPA responses to significant comments,

the contents of the docket will serve as the record in case of judicial

review (section 307(d)(7)(A)).

B. Paperwork Reduction Act

Information collection requirements associated with this regulation

(those included in 40 CFR Part 63, Subpart A and Subpart T) have been

approved by the Office of Management and Budget (OMB) under the

provisions of the Paperwork Reduction Act of 1980, 44 U.S.C. 3501 et

seq. and have been assigned OMB control number (2060-0273). An

Information Collection Request (ICR) document has been prepared by the

EPA (ICR No. 1652.02) to reflect the changed information requirements

of the final rule and has been submitted to OMB for review. A copy may

be obtained from Sandy Farmer, Information Policy Branch, EPA 2136, 401

M St., SW, Washington, DC 20460, or by calling (202) 260-2740.

The annual respondent burden and costs averaged over the first 3

years for batch vapor and in-line cleaning machine subcategories are

359,000 hours and $12.0 million. Since the reporting burden for some of

the required activities will be incurred only once, the average annual

burden for batch vapor and in-line cleaning machine subcategories will

decrease after the first two years of implementation. For the batch

cold cleaning machine subcategory, the annual respondent burden and

costs averaged over the first 3 years are 33,000 hours and $1.1

million. The batch cold cleaning machine subcategory is not expected to

incur costs after the initial activities.

This collection of information is estimated to have an annual

public reporting and recordkeeping burden averaging 42 hours per

facility over the first 3 years. These burden estimates include time

for reviewing instructions, searching existing data sources, gathering

and maintaining the data needed, and completing and reviewing the

collection of information.

Several commenters to the proposed rule in recognizing this burden

noted that the rule was complex and difficult to understand, and

suggested that additional guidance be provided, particularly for small

businesses. To address these concerns the Emission Standards Division

and the Small Business Assistance Program are developing a brochure to

summarize this rule, and will be developing a guidance manual scheduled

to be published in January 1995. This manual will include a detailed

summary of the rule, example forms for reporting and recordkeeping, to

alleviate at least in part the paperwork burden, and additional

material for evaluating alternative cleaning technologies.

Send comments regarding the burden estimate or any other aspects of

this collection of information, including suggestions for reducing this

burden to Chief, Information Policy Branch (2/36), U.S. Environmental

Protection Agency, 401 M St. SW., Washington, DC 20460; and to the

Office of Information and Regulatory Affairs, Office of Management and

Budget, Washington, DC 20503, marked ``Attention: Desk Officer for the

EPA.''

C. Executive Order 12866

Under Executive Order 12866 (58 FR 51735 (October 4, 1993)) the

Agency must determine whether the regulatory action is ``significant''

and therefore subject to OMB review and the requirements of the

Executive Order. The Order defines ``significant regulatory action'' as

one that is likely to result in a rule that may:

(1) Have an annual effect on the economy of $100 million or more or

adversely affect in a material way the economy, a sector of the

economy, productivity, competition, jobs, the environment, public

health or safety, or State, local or tribal governments or communities;

(2) Create a serious inconsistency or otherwise interfere with an

action taken or planned by another agency;

(3) Materially alter the budgetary impact of entitlements, grants,

user fees, or loan programs or the rights and obligations of recipients

thereof; or

(4) Raise novel legal or policy issues arising out of legal

mandates, the President's priorities, or the principles set forth in

the Executive Order.

Pursuant to the terms of the Executive Order, OMB has notified EPA

that it considers this a ``significant regulatory action'' within the

meaning of the Executive Order. The EPA has submitted this action to

OMB for review. Changes made in response to OMB suggestions or

recommendations will be documented in the public record.

D. Regulatory Flexibility Act

The Regulatory Flexibility Act (or RFA, Pub. L. 96-354, September

19, 1980) requires Federal agencies to give special consideration to

the impact of regulation on small businesses. The RFA specifies that a

final regulatory flexibility analysis must be prepared if a proposed

regulation will have a significant economic impact on a substantial

number of small entities. To determine whether a final RFA is required,

a screening analysis, otherwise known as an initial RFA, is necessary.

Regulatory impacts are considered significant if:

(1) Annual compliance costs increase total costs of production by

more than 5 percent; or

(2) Annual compliance costs as a percent of sales are at least 20

percent (percentage points) higher for small entities; or

(3) Capital cost of compliance represents a significant portion of

capital available to small entities; or

(4) The requirements of the regulation are likely to result in

closures of small entities. A ``substantial number'' of small entities

is generally considered to be more than 20 percent of the small

entities in the affected industry. Since the economic analysis deals

only with small entities (in this case, facilities), it is also an

initial RFA, and conclusions about the impacts on small entities can be

drawn from what was done there already. Each of the criteria for

significant impacts will be considered in turn.

The largest increase in total cost of production from increased

emission control is 0.61 percent (SIC 359--Industrial Machinery,

n.e.c.). This figure is well below the significant-impact threshold of

five percent.

Assessing the differential impacts, measured by a comparison of

compliance costs as a percent of sales for small and large entities, is

more difficult as large model facilities were not analyzed in the

economic impact analysis. Treatment of this small business impacts

criterion involves creating two large model facilities.

It is assumed that large facilities use large solvent cleaning

machines, then compliance costs for large cleaning machines are

negative, and are thus savings. To be conservative, it is assumed here

that large model facilities possess five very large solvent cleaning

machines, so that a ``maximum savings'' case is modelled. This case is

important as it models the maximum cost differential between large and

small facilities.

Large model facilities were created for SICs 359 (Industrial

Machinery, n.e.c.) and 254 (Partitions and Fixtures). SIC 359 was

chosen because the small model facilities in this group experience the

highest cost absorption impacts when compared with other small model

facilities. SIC 254 was used because it had the smallest average per-

facility revenue of facilities with greater than 100 employees. Thus,

if they incur the same absolute savings as other large facilities,

their relative percentage savings will be the highest, and they will

experience the greatest cost savings in percentage terms as a result of

the standard. The cost differentials are in no case larger than one

percentage point. Thus, by this criterion, small business impacts are

not deemed significant.

The third criterion focuses on the amount of capital available to

small businesses or facilities. Since the capital costs incurred as a

result of investment in control equipment needed for small businesses

to meet the standard was less than 10 percent of the businesses' total

assets in all 39 affected SIC codes, it was concluded that the total

assets of small facilities will not be so adversely affected as to

prohibit the procurement of outside financing. (Examining an increase

in capital costs as a percentage of total assets is a measure of the

ability of a firm or facility to meet this capital costs increase.) The

conclusion, then, is that lack of available capital will not be an

obstacle for small facilities in complying with the regulation.

Criterion number four stipulates that small business impacts are

significant if compliance leads to closure. The only implication of

closure in the economic impact analysis is found in the section on

earnings impacts. Here it was found that, under worst-case assumptions,

closures might occur in only two SIC codes, 254 and 259 (Miscellaneous

Furniture and Fixtures), given their low rate of profitability in the

baseline. If this indeed occurs, the question of whether or not these

closures make up a substantial portion of small entities must be

addressed. The actual number of impacted facilities in the 39 impacted

SICs is unknown. If it can be assumed that each SIC is impacted in the

same proportion, a proxy for the share of impacted facilities

represented by SIC codes 254 and 259 is the total number of facilities

in these SIC codes as a share of the total number of potentially

impacted firms. SIC codes 254 and 259 hold a combined total 3,194 small

facilities. This makes up 3.4 percent of the total 93,121 small

facilities in all 39 SIC codes. Thus, in the extreme case that some

closures result, the number of closures is estimated to be far less

than the amount required to impact a substantial number of facilities.

In conclusion, and pursuant to section 605(b) of the Regulatory

Flexibility Act, 5 U.S.C. 605(b), the Administrator certifies that this

rule will not have a significant economic impact on a substantial

number of small entities. The basis for the certification is that the

economic impacts for small entities do not meet or exceed the four

criteria in the Guidelines to the Regulatory Flexibility Act of 1980,

as shown above. Further information on the initial RFA is available in

the background information package (see Background Information Document

section near the beginning of this preamble).

List of Subjects in 40 CFR Parts 9 and 63

Environmental Protection, Air pollution control, Hazardous

substances, Halogenated solvent cleaning machines, Reporting and

recordkeeping requirements.

Dated: November 15, 1994.

Carol M. Browner,

Administrator.

For the reasons set out in the preamble, title 40, chapter I, of

the Code of Federal Regulations is amended as set forth below:

PART 9--[AMENDED]

1. The authority citation for part 9 continues to read as follows:

Authority: 7 U.S.C. 135 et seq., 135-136y; 15 U.S.C. 2001, 2003,

2005, 2006, 2601-2671; 21 U.S.C. 331j, 346a, 348; 31 U.S.C. 9701; 33

U.S.C. 1251 et seq., 1311, 1313d, 1314, 1321, 1326, 1330, 1344,

1345(d) and (e), 1361; E.O. 11735, 38 FR 21243, 3 CFR, 1971-1975

Comp. p. 973; 42 U.S.C. 241, 242b, 243, 246, 300f, 300g, 300g-1,

300g-2, 300g-3, 300g-4, 300g-5, 300g-6, 300j-1, 300j-2, 300j-3,

300j-4, 300j-9, 1857 et seq., 6901-6992k, 7401-7671q, 7542, 9601-

9657, 11023, 11048.

2. Section 9.1 is amended by adding in numerical order a new entry

to the table under the indicated heading to read as follows:

Sec. 9.1 OMB approvals under the Paperwork Reduction Act.

* * * * *

------------------------------------------------------------------------

OMB control

40 CFR citation No.

------------------------------------------------------------------------

*****

National Emission Standards for Hazardous Air Pollutants

for Source Categories:

*****

63.467-63.468.............................................. 2060-0273

*****

------------------------------------------------------------------------

PART 63--[AMENDED]

1. The authority citation for part 63 continues to read as follows:

Authority: 42 U.S.C. 7401 et seq.

2. Part 63 is amended by adding subpart T to read as follows:

Subpart T--National Emission Standards for Halogenated Solvent Cleaning

Secs.

63.460 Applicability and designation of source.

63.461 Definitions.

63.462 Batch cold cleaning machine standards.

63.463 Batch vapor and in-line cleaning machine standards.

63.464 Alternative standards.

63.465 Test methods.

63.466 Monitoring procedures.

63.467 Recordkeeping requirements.

63.468 Reporting requirements.

63.469 Equivalent methods of control.

Subpart T--National Emission Standards for Halogenated Solvent

Cleaning

Sec. 63.460 Applicability and designation of source.

(a) The provisions of this subpart apply to each individual batch

vapor, in-line vapor, in-line cold, and batch cold solvent cleaning

machine that uses any solvent containing methylene chloride (CAS No.

75-09-2), perchloroethylene (CAS No. 127-18-4), trichloroethylene (CAS

No. 79-01-6), 1,1,1-trichloroethane (CAS No. 71-55-6), carbon

tetrachloride (CAS No. 56-23-5) or chloroform (CAS No. 67-66-3), or any

combination of these halogenated HAP solvents, in a total concentration

greater than 5 percent by weight, as a cleaning and/or drying agent.

The concentration of these solvents may be determined using EPA test

method 18, material safety data sheets, or engineering calculations.

(b) Except as noted in appendix C (General Provisions Applicability

to Subpart T) of this subpart, the provisions of subpart A of this part

(General Provisions) apply to owners or operators of any solvent

cleaning machine meeting the applicability criteria of paragraph (a) of

this section.

(c) Each solvent cleaning machine subject to this subpart that

commences construction or reconstruction after November 29, 1993, shall

achieve compliance with the provisions of this subpart immediately upon

startup or by December 2, 1994, whichever is later.

``(d) Each solvent cleaning machine subject to this subpart that

commenced construction or reconstruction on or before November 29,

1993, shall achieve compliance with the provisions of this subpart no

later than.

(e) In delegating implementation and enforcement authority to a

State under section 112(d) of the Act, the authority contained in

paragraph (f) of this section shall be retained by the Administrator

and not transferred to a State.

(f) The authority conferred in Sec. 63.463(d)(9) and Sec. 63.469

will not be delegated to any State.

Sec. 63.461 Definitions.

Unless defined below, all terms used in this subpart are used as

defined in the 1990 Clean Air Act, or in subpart A of 40 CFR part 63:

Administrator means the Administrator of the United States

Environmental Protection Agency or his or her authorized representative

(e.g., State that has been delegated the authority to implement the

provisions of this part.)

Air blanket means the layer of air inside the solvent cleaning

machine freeboard located above the solvent/air interface. The

centerline of the air blanket is equidistant between the sides of the

machine.

Automated parts handling system means a mechanical device that

carries all parts and parts baskets at a controlled speed from the

initial loading of soiled or wet parts through the removal of the

cleaned or dried parts. Automated parts handling systems include, but

are not limited to, hoists and conveyors.

Batch cleaning machine means a solvent cleaning machine in which

individual parts or a set of parts move through the entire cleaning

cycle before new parts are introduced into the solvent cleaning

machine. An open-top vapor cleaning machine is a type of batch cleaning

machine. A solvent cleaning machine, such as a ferris wheel cleaner,

that cleans multiple batch loads simultaneously and is manually loaded

is a batch cleaning machine.

Carbon adsorber means a bed of activated carbon into which an air-

solvent gas-vapor stream is routed and which adsorbs the solvent on the

carbon.

Clean liquid solvent means fresh unused solvent, recycled solvent,

or used solvent that has been cleaned of soils (e.g., skimmed of oils

or sludge and strained of metal chips).

Cleaning capacity means, for a cleaning machine without a solvent/

air interface, the maximum volume of parts that can be cleaned at one

time. In most cases, the cleaning capacity is equal to the volume

(length times width times height) of the cleaning chamber.

Cold cleaning machine means any device or piece of equipment that

contains and/or uses liquid solvent, into which parts are placed to

remove soils from the surfaces of the parts or to dry the parts.

Cleaning machines that contain and use heated, nonboiling solvent to

clean the parts are classified as cold cleaning machines.

Consumption means the amount of halogenated hazardous air pollutant

solvent added to the solvent cleaning machine.

Cover means a lid, top, or portal cover that shields the solvent

cleaning machine openings from air disturbances when in place and is

designed to be easily opened and closed without disturbing the vapor

zone. Air disturbances include, but are not limited to, lip exhausts,

ventilation fans, and general room drafts. Types of covers include, but

are not limited to, sliding, biparting, and rolltop covers.

Downtime mode means the time period when a solvent cleaning machine

is not cleaning parts and the sump heating coils, if present, are

turned off.

Dwell means the technique of holding parts within the freeboard

area but above the vapor zone of the solvent cleaning machine. Dwell

occurs after cleaning to allow solvent to drain from the parts or parts

baskets back into the solvent cleaning machine.

Dwell time means the required minimum length of time that a part

must dwell, as determined by Sec. 63.465(d).

Emissions means halogenated hazardous air pollutant solvent

consumed (i.e., halogenated hazardous air pollutant solvent added to

the machine) minus the liquid halogenated hazardous air pollutant

solvent removed from the machine and the halogenated hazardous air

pollutant solvent removed from the machine in the solid waste.

Existing means any solvent cleaning machine the construction or

reconstruction of which was commenced on or before November 29, 1993.

Freeboard area means; for a batch cleaning machine, the area within

the solvent cleaning machine that extends from the solvent/air

interface to the top of the solvent cleaning machine; for an in-line

cleaning machine, it is the area within the solvent cleaning machine

that extends from the solvent/air interface to the bottom of the

entrance or exit opening, whichever is lower.

Freeboard height means; for a batch cleaning machine, the distance

from the solvent/air interface, as measured during the idling mode, to

the top of the cleaning machine; for an in-line cleaning machine, it is

the distance from the solvent/air interface to the bottom of the

entrance or exit opening, whichever is lower, as measured during the

idling mode.

Freeboard ratio means the ratio of the solvent cleaning machine

freeboard height to the smaller interior dimension (length, width, or

diameter) of the solvent cleaning machine.

Freeboard refrigeration device (also called a chiller) means a set

of secondary coils mounted in the freeboard area that carries a

refrigerant or other chilled substance to provide a chilled air blanket

above the solvent vapor. A primary condenser capable of meeting the

requirements of Sec. 63.463(e)(2)(i) is defined as both a freeboard

refrigeration device and a primary condenser for the purposes of these

standards.

Halogenated hazardous air pollutant solvent or halogenated HAP

solvent means methylene chloride (CAS No. 75-09-2), perchloroethylene

(CAS No. 127-18-4), trichloroethylene (CAS No. 79-01-6), 1,1,1-

trichloroethane (CAS No. 71-55-6), carbon tetrachloride (CAS No. 56-23-

5), and chloroform (CAS No. 67-66-3).

Hoist means a mechanical device that carries the parts basket and

the parts to be cleaned from the loading area into the solvent cleaning

machine and to the unloading area at a controlled speed. A hoist may be

operated by controls or may be programmed to cycle parts through the

cleaning cycle automatically.

Idling mode means the time period when a solvent cleaning machine

is not actively cleaning parts and the sump heating coils, if present,

are turned on.

Idling-mode cover means any cover or solvent cleaning machine

design that allows the cover to shield the cleaning machine openings

during the idling mode. A cover that meets this definition can also be

used as a working-mode cover if that definition is also met.

Immersion cold cleaning machine means a cold cleaning machine in

which the parts are immersed in the solvent when being cleaned. A

remote reservoir cold cleaning machine that is also an immersion cold

cleaning machine is considered an immersion cold cleaning machine for

purposes of this subpart.

In-line cleaning machine or continuous cleaning machine means a

solvent cleaning machine that uses an automated parts handling system,

typically a conveyor, to automatically provide a continuous supply of

parts to be cleaned. These units are fully enclosed except for the

conveyor inlet and exit portals. In-line cleaning machines can be

either cold or vapor cleaning machines.

Leak-proof coupling means a threaded or other type of coupling that

prevents solvents from leaking while filling or draining solvent to and

from the solvent cleaning machine.

Lip exhaust means a device installed at the top of the opening of a

solvent cleaning machine that draws in air and solvent vapor from the

freeboard area and ducts the air and vapor away from the solvent

cleaning area.

Monthly reporting period means any calendar month in which the

owner or operator of a solvent cleaning machine is required to

calculate and report the solvent emissions from each solvent cleaning

machine.

New means any solvent cleaning machine the construction or

reconstruction of which is commenced after November 29, 1993.

Open-top vapor cleaning machine means a batch solvent cleaning

machine that has its upper surface open to the air and boils solvent to

create solvent vapor used to clean and/or dry parts.

Part means any object that is cleaned in a solvent cleaning

machine. Parts include, but are not limited to, discrete parts,

assemblies, sets of parts, and continuous parts (i.e., continuous

sheets of metal).

Primary condenser means a series of circumferential cooling coils

on a vapor cleaning machine through which a chilled substance is

circulated or recirculated to provide continuous condensation of rising

solvent vapors and, thereby, create a concentrated solvent vapor zone.

Reduced room draft means decreasing the flow or movement of air

across the top of the freeboard area of the solvent cleaning machine to

meet the specifications of Sec. 63.463(e)(2)(ii). Methods of achieving

a reduced room draft include, but are not limited to, redirecting fans

and/or air vents to not blow across the cleaning machine, moving the

cleaning machine to a corner where there is less room draft, and

constructing a partial or complete enclosure around the cleaning

machine.

Remote reservoir cold cleaning machine means any device in which

liquid solvent is pumped to a sink-like work area that drains solvent

back into an enclosed container while parts are being cleaned, allowing

no solvent to pool in the work area.

Soils means contaminants that are removed from the parts being

cleaned. Soils include, but are not limited to, grease, oils, waxes,

metal chips, carbon deposits, fluxes, and tars.

Solvent/air interface means, for a vapor cleaning machine, the

location of contact between the concentrated solvent vapor layer and

the air. This location of contact is defined as the mid-line height of

the primary condenser coils. For a cold cleaning machine, it is the

location of contact between the liquid solvent and the air.

Solvent/air interface area means; for a vapor cleaning machine, the

surface area of the solvent vapor zone that is exposed to the air; for

an in-line cleaning machine, it is the total surface area of all the

sumps; for a cold cleaning machine, it is the surface area of the

liquid solvent that is exposed to the air.

Solvent cleaning machine means any device or piece of equipment

that uses halogenated HAP solvent liquid or vapor to remove soils from

the surfaces of materials. Types of solvent cleaning machines include,

but are not limited to, batch vapor, in-line vapor, in-line cold, and

batch cold solvent cleaning machines.

Solvent vapor zone means; for a vapor cleaning machine, the area

that extends from the liquid solvent surface to the level that solvent

vapor is condensed. This condensation level is defined as the midline

height of the primary condenser coils.

Sump means the part of a solvent cleaning machine where the liquid

solvent is located.

Sump heater coils means the heating system on a cleaning machine

that uses steam, electricity, or hot water to heat or boil the liquid

solvent.

Superheated vapor system means a system that heats the solvent

vapor, either passively or actively, to a temperature above the

solvent's boiling point. Parts are held in the superheated vapor before

exiting the machine to evaporate the liquid solvent on them. Hot vapor

recycle is an example of a superheated vapor system.

Vapor cleaning machine means a batch or in-line solvent cleaning

machine that boils liquid solvent generating solvent vapor that is used

as a part of the cleaning or drying cycle.

Water layer means a layer of water that floats above the denser

solvent and provides control of solvent emissions. In many cases, the

solvent used in batch cold cleaning machines is sold containing the

appropriate amount of water to create a water cover.

Working mode means the time period when the solvent cleaning

machine is actively cleaning parts. Working-mode cover means anycover

or solvent cleaning machine design that allows the cover to shield the

cleaning machine openings from outside air disturbances while parts are

being cleaned in the cleaning machine. A cover that is used during the

working mode is opened only during parts entry and removal. A cover

that meets this definition can also be used as an idling-mode cover if

that definition is also met.

Sec. 63.462 Batch cold cleaning machine standards.

(a) Each owner or operator of an immersion batch cold solvent

cleaning machine shall comply with the requirements specified in

paragraph(a)(1) or (a)(2) of this section.

(1) Employ a tightly fitting cover that shall be closed at all

times except during parts entry and removal, and a water layer at a

minimum thickness of 2.5 centimeters (1.0 inch) on the surface of the

solvent within the cleaning machine, or

(2) Employ a tightly fitting cover that shall be closed at all

times except during parts entry and removal and a freeboard ratio of

0.75 or greater.

(b) Each owner or operator of a remote-reservoir batch cold solvent

cleaning machine shall employ a tightly fitting cover over the solvent

sump that shall be closed at all times except during the cleaning of

parts.

(c) Each owner or operator of a batch cold solvent cleaning machine

complying with paragraphs (a)(2) or (b) of this section shall comply

with the work and operational practice requirements specified in

paragraphs (c)(1) through (c)(8) of this section.

(1) All waste solvent shall be collected and stored in closed

containers. The closed container may contain a device that allows

pressure relief, but does not allow liquid solvent to drain from the

container.

(2) If a flexible hose or flushing device is used, flushing shall

be performed only within the freeboard area of the solvent cleaning

machine.

(3) The owner or operator shall drain solvent cleaned parts for 15

seconds or until dripping has stopped, whichever is longer. Parts

having cavities or blind holes shall be tipped or rotated while

draining.

(4) The owner or operator shall ensure that the solvent level does

not exceed the fill line.

(5) Spills during solvent transfer shall be wiped up immediately.

The wipe rags shall be stored in covered containers meeting the

requirements of paragraph (c)(1) of this section.

(6) When an air- or pump-agitated solvent bath is used, the owner

or operator shall ensure that the agitator is operated to produce a

rolling motion of the solvent but not observable splashing against tank

walls or parts being cleaned.

(7) The owner or operator shall ensure that, when the cover is

open, the cold cleaning machine is not exposed to drafts greater than

40 meters per minute (132 feet per minute), as measured between 1 and 2

meters (3.3 and 6.6 feet) upwind and at the same elevation as the tank

lip.

(8) Sponges, fabric, wood, and paper products shall not be cleaned.

(d) Each owner or operator of a batch cold cleaning machine shall

submit an initial notification report as described in Sec. 63.468(a)

and a compliance report as described in Sec. 63.468(b). No further

reporting or recordkeeping is required.

Sec. 63.463 Batch vapor and in-line cleaning machine standards.

(a) Except as provided in Sec. 63.464, each owner or operator of a

solvent cleaning machine subject to the provisions of this subpart

shall ensure that each existing or new batch vapor or in-line solvent

cleaning machine subject to the provisions of this subpart conforms to

the design requirements specified in paragraphs (a)(1) through (a)(7)

of this section.

(1) Each cleaning machine shall be designed or operated to meet the

control equipment or technique requirements in paragraph (a)(1)(i) or

(a)(1)(ii) of this section.

(i) An idling and downtime mode cover, as described in

Sec. 63.463(d)(1)(i), that may be readily opened or closed, that

completely covers the cleaning machine openings when in place, and is

free of cracks, holes, and other defects.

(ii) A reduced room draft as described in Sec. 63.463(e)(2)(ii).

(2) Each cleaning machine shall have a freeboard ratio of 0.75 or

greater.

(3) Each cleaning machine shall have an automated parts handling

system capable of moving parts or parts baskets at a speed of 3.4

meters per minute (11 feet per minute) or less from the initial loading

of parts through removal of cleaned parts.

(4) Each vapor cleaning machine shall be equipped with a device

that shuts off the sump heat if the sump liquid solvent level drops to

the sump heater coils.

(5) Each vapor cleaning machine shall be equipped with a vapor

level control device that shuts off sump heat if the vapor level in the

vapor cleaning machine rises above the height of the primary condenser.

(6) Each vapor cleaning machine shall have a primary condenser.

(7) Each cleaning machine that uses a lip exhaust shall be designed

and operated to route all collected solvent vapors through a properly

operated and maintained carbon adsorber that meets the requirements of

paragraph (e)(2)(vii) of this section.

(b) Except as provided in Sec. 63.464, each owner or operator of an

existing or new batch vapor cleaning machine shall comply with either

paragraph (b)(1) or (b)(2) of this section.

(1) Each owner or operator of a batch vapor cleaning machine with a

solvent/air interface area of 1.21 square meters (13 square feet) or

less shall comply with the requirements specified in either paragraph

(b)(1)(i) or (b)(1)(ii) of this section.

(i) Employ one of the control combinations listed in table 1 of

this subpart or other equivalent methods of control as determined using

the procedure in Sec. 63.469, equivalent methods of control.

Table 1.--Control Combinations for Batch Vapor Solvent Cleaning Machines

With a Solvent/Air Interface Area of 1.21 Square Meters (13 Square Feet)

or Less

------------------------------------------------------------------------

Option Control combinations

------------------------------------------------------------------------

1......... Working-mode cover, freeboard ratio of 1.0, superheated

vapor.

2......... Freeboard refrigeration device, superheated vapor.

3......... Working-mode cover, freeboard refrigeration device.

4......... Reduced room draft, freeboard ratio of 1.0, superheated

vapor.

5......... Freeboard refrigeration device, reduced room draft.

6......... Freeboard refrigeration device, freeboard ratio of 1.0.

7......... Freeboard refrigeration device, dwell.

8......... Reduced room draft, dwell, freeboard ratio of 1.0.

9......... Freeboard refrigeration device, carbon adsorber.

10........ Freeboard ratio of 1.0, superheated vapor, carbon adsorber.

------------------------------------------------------------------------

Note: Unlike most of the control techniques available for complying with

this rule, carbon adsorbers are not considered to be a pollution

prevention measure. Use of such units may impose additional cost and

burden for a number of reasons. First, carbon adsorption units are

generally more expensive than other controls listed in the options.

Second, these units may present cross-media impacts such as effluent

discharges if not properly operated and maintained, and spent carbon

beds have to be disposed of as hazardous waste. When making decisions

about what controls to install on halogenated solvent cleaning

machines to meet the requirements of this rule, all of these factors

should be weighed and pollution prevention measures are encouraged

wherever possible.

(ii) Demonstrate that their solvent cleaning machine can achieve

and maintain an idling emission limit of 0.22 kilograms per hour per

square meter (0.045 pounds per hour per square foot) of solvent/air

interface area as determined using the procedures in Sec. 63.465(a) and

appendix A to this part.

(2) Each owner or operator of a batch vapor cleaning machine with a

solvent/air interface area greater than 1.21 square meters (13 square

feet) shall comply with the requirements specified in either paragraph

(b)(2)(i) or (b)(2)(ii) of this section.

(i) Employ one of the control combinations listed in table 2 of

this subpart or other equivalent methods of control as determined using

the procedure in Sec. 63.469, equivalent methods of control.

Table 2.--Control Combinations for Batch Vapor Solvent Cleaning Machines

With a Solvent/Air Interface Area Greater than 1.21 Square Meters (13

Square Feet)

------------------------------------------------------------------------

Option Control combinations

------------------------------------------------------------------------

1......... Freeboard refrigeration device, freeboard ratio of 1.0,

superheated vapor.

2......... Dwell, freeboard refrigeration device, reduced room draft.

3......... Working-mode cover, freeboard refrigeration device,

superheated vapor.

4......... Freeboard ratio of 1.0, reduced room draft, superheated

vapor.

5......... Freeboard refrigeration device, reduced room draft,

superheated vapor.

6......... Freeboard refrigeration device, reduced room draft,

freeboard ratio of 1.0.

7......... Freeboard refrigeration device, superheated vapor, carbon

adsorber.

------------------------------------------------------------------------

Note: Unlike most of the control techniques available for complying with

this rule, carbon adsorbers are not considered to be a pollution

prevention measure. Use of such units may impose additional cost and

burden for a number of reasons. First, carbon adsorption units are

generally more expensive than other controls listed in the options.

Second, these units may present cross-media impacts such as effluent

discharges if not properly operated and maintained, and spent carbon

beds have to be disposed of as hazardous waste. When making decisions

about what controls to install on halogenated solvent cleaning

machines to meet the requirements of this rule, all of these factors

should be weighed and pollution prevention measures are encouraged

wherever possible.

(ii) Demonstrate that their solvent cleaning machine can achieve

and maintain an idling emission limit of 0.22 kilograms per hour per

square meter (0.045 pounds per hour per square foot) of solvent/air

interface area as determined using the procedures in Sec. 63.465(a) and

appendix A of this part.

(c) Except as provided in Sec. 63.464, each owner or operator of an

in-line cleaning machine shall comply with paragraph (c)(1) or (c)(2)

of this section as appropriate.

(1) Each owner or operator of an existing in-line cleaning machine

shall comply with the requirements specified in either paragraph

(c)(1)(i) or (c)(1)(ii) of this section.

(i) Employ one of the control combinations listed in table 3 of

this subpart or other equivalent methods of control as determined using

the procedure in Sec. 63.469, equivalent methods of control.

Table 3.--Control Combinations for Existing In-Line Solvent Cleaning

Machines

------------------------------------------------------------------------

Option Control combinations

------------------------------------------------------------------------

1......... Superheated vapor, freeboard ratio of 1.0.

2......... Freeboard refrigeration device, freeboard ratio of 1.0.

3......... Dwell, freeboard refrigeration device.

4......... Dwell, carbon adsorber.

------------------------------------------------------------------------

Note: Unlike most of the control techniques available for complying with

this rule, carbon adsorbers are not considered to be a pollution

prevention measure. Use of such units may impose additional cost and

burden for a number of reasons. First, carbon adsorption units are

generally more expensive than other controls listed in the options.

Second, these units may present cross-media impacts such as effluent

discharges if not properly operated and maintained, and spent carbon

beds have to be disposed of as hazardous waste. When making decisions

about what controls to install on halogenated solvent cleaning

machines to meet the requirements of this rule, all of these factors

should be weighed and pollution prevention measures are encouraged

wherever possible.

(ii) Demonstrate that their solvent cleaning machine can achieve

and maintain an idling emission limit of 0.10 kilograms per hour per

square meter (0.021 pounds per hour per square foot) of solvent/air

interface area as determined using the procedures in Sec. 63.465(a) and

appendix A to this part.

(2) Each owner or operator of a new in-line cleaning machine shall

comply with the requirements specified in either paragraph (c)(2)(i) or

(c)(2)(ii) of this section.

(i) Employ one of the control combinations listed in table 4 of

this subpart or other equivalent methods of control as determined using

the procedure in Sec. 63.469, equivalent methods of control section.

Table 4.--Control Combinations for New In-Line Solvent Cleaning Machines

------------------------------------------------------------------------

Option Control combinations

------------------------------------------------------------------------

1......... Superheated vapor, freeboard refrigeration device.

2......... Freeboard refrigeration device, carbon adsorber.

3......... Superheated vapor, carbon adsorber.

------------------------------------------------------------------------

Note: Unlike most of the control techniques available for complying with

this rule, carbon adsorbers are not considered to be a pollution

prevention measure. Use of such units may impose additional cost and

burden for a number of reasons. First, carbon adsorption units are

generally more expensive than other controls listed in the options.

Second, these units may present cross-media impacts such as effluent

discharges if not properly operated and maintained, and spent carbon

beds have to be disposed of as hazardous waste. When making decisions

about what controls to install on halogenated solvent cleaning

machines to meet the requirements of this rule, all of these factors

should be weighed and pollution prevention measures are encouraged

wherever possible.

(ii) Demonstrate that their solvent cleaning machine can achieve

and maintain an idling emission limit of 0.10 kilograms per hour per

square meter (0.021 pounds per hour per square foot) of solvent/air

interface area as determined using the procedures in Sec. 63.465(a) and

appendix A to this part.

(d) Except as provided in Sec. 63.464, each owner or operator of an

existing or new batch vapor or in-line solvent cleaning machine shall

meet all of the following required work and operational practices

specified in paragraph (d)(1) through (d)(12) of this section as

applicable.

(1) Control air disturbances across the cleaning machine opening(s)

by incorporating the control equipment or techniques in paragraph

(d)(1)(i) or (d)(1)(ii) of this section.

(i) Cover(s) to each solvent cleaning machine shall be in place

during the idling mode, and during the downtime mode unless either the

solvent has been removed from the machine or maintenance or monitoring

is being performed that requires the cover(s) to not be in place.

(ii) A reduced room draft as described in Sec. 63.463(e)(2)(ii).

(2) The parts baskets or the parts being cleaned in an open-top

batch vapor cleaning machine shall not occupy more than 50 percent of

the solvent/air interface area unless the parts baskets or parts are

introduced at a speed of 0.9 meters per minute (3 feet per minute) or

less.

(3) Any spraying operations shall be done within the vapor zone or

within a section of the solvent cleaning machine that is not directly

exposed to the ambient air (i.e., a baffled or enclosed area of the

solvent cleaning machine).

(4) Parts shall be oriented so that the solvent drains from them

freely. Parts having cavities or blind holes shall be tipped or rotated

before being removed from any solvent cleaning machine unless an

equally effective approach has been approved by the Administrator.

(5) Parts baskets or parts shall not be removed from any solvent

cleaning machine until dripping has stopped.

(6) During startup of each vapor cleaning machine, the primary

condenser shall be turned on before the sump heater.

(7) During shutdown of each vapor cleaning machine, the sump heater

shall be turned off and the solvent vapor layer allowed to collapse

before the primary condenser is turned off.

(8) When solvent is added or drained from any solvent cleaning

machine, the solvent shall be transferred using threaded or other

leakproof couplings and the end of the pipe in the solvent sump shall

be located beneath the liquid solvent surface.

(9) Each solvent cleaning machine and associated controls shall be

maintained as recommended by the manufacturers of the equipment or

using alternative maintenance practices that have been demonstrated to

the Administrator's satisfaction to achieve the same or better results

as those recommended by the manufacturer.

(10) Each operator of a solvent cleaning machine shall complete and

pass the applicable sections of the test of solvent cleaning operating

procedures in appendix B to this part if requested during an inspection

by the Administrator.

(11) Waste solvent, still bottoms, and sump bottoms shall be

collected and stored in closed containers. The closed containers may

contain a device that would allow pressure relief, but would not allow

liquid solvent to drain from the container.

(12) Sponges, fabric, wood, and paper products shall not be

cleaned.

(e) Each owner or operator of a solvent cleaning machine complying

with either paragraph (b) or (c) of this section shall comply with the

requirements specified in paragraphs (e)(1) through (e)(4) of this

section.

(1) Conduct monitoring of each control device used to comply with

Sec. 63.463 of this subpart as provided in Sec. 63.466.

(2) Determine during each monitoring period whether each control

device used to comply with these standards meets the requirements

specified in paragraphs (e)(2)(i) through (e)(2)(vii) of this section.

(i) If a freeboard refrigeration device is used to comply with

these standards, the owner or operator shall ensure that the chilled

air blanket temperature (in deg.F or deg.C), measured at the center

of the air blanket, is no greater than 30 percent of the solvent's

boiling point.

(ii) If a reduced room draft is used to comply with these

standards, the owner or operator shall comply with the requirements

specified in paragraphs (e)(2)(ii)(A) and (e)(2)(ii)(B) of this

section.

(A) Ensure that the flow or movement of air across the top of the

freeboard area of the solvent cleaning machine or within the solvent

cleaning machine enclosure does not exceed 15.2 meters per minute (50

feet per minute) at any time as measured using the procedures in

Sec. 63.466(d).

(B) Establish and maintain the operating conditions under which the

wind speed was demonstrated to be 15.2 meters per minute (50 feet per

minute) or less as described in Sec. 63.466(d).

(iii) If a working-mode cover is used to comply with these

standards, the owner or operator shall comply with the requirements

specified in paragraphs (e)(2)(iii)(A) and (e)(2)(iii)(B) of this

section.

(A) Ensure that the cover opens only for part entrance and removal

and completely covers the cleaning machine openings when closed.

(B) Ensure that the working-mode cover is maintained free of

cracks, holes, and other defects.

(iv) If an idling-mode cover is used to comply with these

standards, the owner or operator shall comply with the requirements

specified in paragraphs (e)(2)(iv)(A) and (e)(2)(iv)(B) of this

section.

(A) Ensure that the cover is in place whenever parts are not in the

solvent cleaning machine and completely covers the cleaning machine

openings when in place.

(B) Ensure that the idling-mode cover is maintained free of cracks,

holes, and other defects.

(v) If a dwell is used to comply with these standards, the owner or

operator shall comply with the requirements specified in paragraphs

(e)(2)(v)(A) and (e)(2)(v)(B) of this section.

(A) Determine the appropriate dwell time for each type of part or

parts basket, or determine the maximum dwell time using the most

complex part type or parts basket, as described in Sec. 63.465(d).

(B) Ensure that, after cleaning, each part is held in the solvent

cleaning machine freeboard area above the vapor zone for the dwell time

determined for that particular part or parts basket, or for the maximum

dwell time determined using the most complex part type or parts basket.

(vi) If a superheated vapor system is used to comply with these

standards, the owner or operator shall comply with the requirements

specified in paragraphs (e)(2)(vi)(A) through (e)(2)(vi)(C) of this

section.

(A) Ensure that the temperature of the solvent vapor at the center

of the superheated vapor zone is at least 10 deg.F above the solvent's

boiling point.

(B) Ensure that the manufacturer's specifications for determining

the minimum proper dwell time within the superheated vapor system is

followed.

(C) Ensure that parts remain within the superheated vapor for at

least the minimum proper dwell time.

(vii) If a carbon adsorber in conjunction with a lip exhaust is

used to comply with these standards, the owner or operator shall comply

with the requirements specified in paragraphs (e)(2)(vii)(A) through

(e)(2)(vii)(C) of this section.

(A) Ensure that the concentration of organic solvent in the exhaust

from this device does not exceed 100 parts per million of any

halogenated HAP compound as measured using the procedure in

Sec. 63.466(e). If the halogenated HAP solvent concentration in the

carbon adsorber exhaust exceeds 100 parts per million, the owner or

operator shall adjust the desorption schedule or replace the disposable

canister, if not a regenerative system, so that the exhaust

concentration of halogenated HAP solvent is brought below 100 parts per

million.

(B) Ensure that the carbon adsorber bed is not bypassed during

desorption.

(C) Ensure that the lip exhaust is located above the solvent

cleaning machine cover so that the cover closes below the lip exhaust

level.

(3) If any of the requirements of paragraph (e)(2) of this section

are not met, determine whether an exceedance has occurred using the

criteria in paragraphs (e)(3)(i) and (e)(3)(ii) of this section.

(i) An exceedance has occurred if the requirements of paragraphs

(e)(2)(ii)(B), (e)(2)(iii)(A), (e)(2)(iv)(A), (e)(2)(v), (e)(2)(vi)(B),

(e)(2)(vi)(C), (e)(2)(vii)(B), or (e)(2)(vii)(C) of this section have

not been met.

(ii) An exceedance has occurred if the requirements of paragraphs

(e)(2)(i), (e)(2)(ii)(A), (e)(2)(iii)(B), (e)(2)(iv)(B), (e)(2)(vi)(A),

or (e)(2)(vii)(A) of this section have not been met and are not

corrected within 15 days of detection. Adjustments or repairs shall be

made to the solvent cleaning system or control device to reestablish

required levels. The parameter must be remeasured immediately upon

adjustment or repair and demonstrated to be within required limits.

(4) The owner or operator shall report all exceedances and all

corrections and adjustments made to avoid an exceedance as specified in

Sec. 63.468(h).

(f) Each owner or operator of a batch vapor or in-line solvent

cleaning machine complying with the idling emission limit standards in

paragraphs (b)(1)(ii), (b)(2)(ii), (c)(1)(ii), or (c)(2)(ii) of this

section shall comply with the requirements specified in paragraphs

(f)(1) through (f)(5) of this section.

(1) Conduct an initial performance test to comply with the

requirements specified in paragraphs (f)(1)(i) and (f)(1)(ii) of this

section.

(i) Demonstrate compliance with the applicable idling emission

limit.

(ii) Establish parameters that will be monitored to demonstrate

compliance. If a control device is used that is listed in paragraph

(e)(2) of this section, then the requirements for that control device

as listed in paragraph (e)(2) of this section shall be used unless the

owner or operator can demonstrate to the Administrator's satisfaction

that an alternative strategy is equally effective.

(2) Conduct the periodic monitoring of the parameters used to

demonstrate compliance as described in Sec. 63.466(f).

(3) Operate the solvent cleaning machine within parameters

identified in the initial performance test.

(4) If any of the requirements in paragraphs (f)(1) through (f)(3)

of this section are not met, determine whether an exceedance has

occurred using the criteria in paragraphs (f)(4)(i) and (f)(4)(ii) of

this section.

(i) If using a control listed in paragraph (e) of this section, the

owner or operator shall comply with the appropriate parameter values in

paragraph (e)(2) and the exceedance delineations in paragraphs

(e)(3)(i) and (e)(3)(ii) of this section.

(ii) If using a control not listed in paragraph (e) of this

section, the owner or operator shall indicate whether the exceedance of

the parameters that are monitored to determine the proper functioning

of this control would be classified as an immediate exceedance or

whether a 15 day repair period would be allowed. This information must

be submitted to the Administrator for approval.

(5) The owner or operator shall report all exceedances and all

corrections and adjustments made to avoid an exceedance as specified in

Sec. 63.468(h).

Sec. 63.464 Alternative standards.

(a) As an alternative to meeting the requirements in Sec. 63.463,

each owner or operator of a batch vapor or in-line solvent cleaning

machine can elect to comply with the requirements of Sec. 63.464. An

owner or operator of a solvent cleaning machine who elects to comply

with Sec. 63.464 shall comply with the requirements specified in either

paragraph (a)(1) or (a)(2) of this section.

(1) If the cleaning machine has a solvent/air interface, as defined

in Sec. 63.461, the owner or operator shall comply with the

requirements specified in paragraphs (a)(1)(i) and (a)(1)(ii) of this

section.

(i) Maintain a log of solvent additions and deletions for each

solvent cleaning machine.

(ii) Ensure that the emissions from each solvent cleaning machine

are equal to or less than the applicable emission limit presented in

table 5 of this subpart as determined using the procedures in

Sec. 63.465(b) and (c).

Table 5.--Emission Limits for Batch Vapor and In-Line Solvent Cleaning

Machines With a Solvent/Air Interface

------------------------------------------------------------------------

3-month

rolling

average

monthly

emission

Solvent cleaning machine limit

(kilograms/

square

meters/

month)

------------------------------------------------------------------------

Batch vapor solvent cleaning machines...................... 150

Existing in-line solvent cleaning machines................. 153

New in-line solvent cleaning machines...................... 99

------------------------------------------------------------------------

(2) If the cleaning machine is a batch vapor cleaning machine and

does not have a solvent/air interface, the owner or operator shall

comply with the requirements specified in paragraphs (a)(2)(i) and

(a)(2)(ii) of this section.

(i) Maintain a log of solvent additions and deletions for each

solvent cleaning machine.

(ii) Ensure that the emissions from each solvent cleaning machine

are equal to or less than the appropriate limits as described in

paragraphs (a)(2)(ii)(A) and (a)(2)(ii)(B) of this section.

(A) For cleaning machines with a cleaning capacity, as reported in

Sec. 63.468(d), that is less than or equal to 2.95 cubic meters, the

emission limit shall be determined using table 6 or equation 1. If

using table 6, and the cleaning capacity of the cleaning machine falls

between two cleaning capacity sizes, then the lower of the two emission

limits applies.

(B) For cleaning machines with a cleaning capacity as reported in

Sec. 63.468(d), that is greater than 2.95 cubic meters, the emission

limit shall be determined using equation 1.

EL = 330 * (Vol)0.6 (1)

where:

EL = the 3-month rolling average monthly emission limit (kilograms/

month).

Table 6.--Emission Limits for Cleaning Machines Without a Solvent/Air

Interface

------------------------------------------------------------------------

3-month rolling average monthly

Cleaning capacity (cubic meters) emission limit (kilograms/month)

------------------------------------------------------------------------

0.00.............................. 0

0.05.............................. 55

0.10.............................. 83

0.15.............................. 106

0.20.............................. 126

0.25.............................. 144

0.30.............................. 160

0.35.............................. 176

0.40.............................. 190

0.45.............................. 204

0.50.............................. 218

0.55.............................. 231

0.60.............................. 243

0.65.............................. 255

0.70.............................. 266

0.75.............................. 278

0.80.............................. 289

0.85.............................. 299

0.90.............................. 310

0.95.............................. 320

1.00.............................. 330

1.05.............................. 340

1.10.............................. 349

1.15.............................. 359

1.20.............................. 368

1.25.............................. 377

1.30.............................. 386

1.35.............................. 395

1.40.............................. 404

1.45.............................. 412

1.50.............................. 421

1.55.............................. 429

1.60.............................. 438

1.65.............................. 446

1.70.............................. 454

1.75.............................. 462

1.80.............................. 470

1.85.............................. 477

1.90.............................. 485

1.95.............................. 493

2.00.............................. 500

2.05.............................. 508

2.10.............................. 515

2.15.............................. 522

2.20.............................. 530

2.25.............................. 537

2.30.............................. 544

2.35.............................. 551

2.40.............................. 558

2.45.............................. 565

2.50.............................. 572

2.55.............................. 579

2.60.............................. 585

2.65.............................. 592

2.70.............................. 599

2.75.............................. 605

2.80.............................. 612

2.85.............................. 619

2.90.............................. 625

2.95.............................. 632

------------------------------------------------------------------------

Vol = the cleaning capacity of the solvent cleaning machine (cubic

meters).

(b) Each owner or operator of a batch vapor or in-line solvent

cleaning machine complying with Sec. 63.464(a) shall demonstrate

compliance with the applicable 3-month rolling average monthly emission

limit on a monthly basis as described in Sec. 63.465(b) and (c).

(c) If the applicable 3-month rolling average emission limit is not

met, an exceedance has occurred. All exceedances shall be reported as

required in Sec. 63.468(h).

Sec. 63.465 Test methods.

(a) Each owner or operator of a batch vapor or in-line solvent

cleaning machine complying with an idling emission limit standard in

Sec. 63.463(b)(1)(ii), (b)(2)(ii), (c)(1)(ii), or (c)(2)(ii) shall

determine the idling emission rate of the solvent cleaning machine

using Reference Method 307 in appendix A to this part.

(b) Each owner or operator of a batch vapor or in-line solvent

cleaning machine complying with Sec. 63.464 shall on the first

operating day of every month ensure that the solvent cleaning machine

system contains only clean liquid solvent. This includes, but is not

limited to, fresh unused solvent, recycled solvent and used solvent

that has been cleaned of soils. A fill line must be indicated during

the first month the measurements are made. The solvent level within the

machine must be returned to the same fill-line each month, immediately

prior to calculating monthly emissions as specified in Sec. 63.465(c).

The solvent cleaning machine does not have to be emptied and filled

with fresh unused solvent prior to the calculations.

(c) Each owner or operator of a batch vapor or in-line solvent

cleaning machine complying with Sec. 63.464 shall on the first

operating day of the month comply with the requirements specified in

paragraphs (c)(1) through (c)(3) of this section.

(1) Using the records of all solvent additions and deletions for

the previous monthly reporting period required under Sec. 63.464(a),

determine solvent emissions (Ei) using equation 2 for cleaning machines

with a solvent/air interface and equation 3 for cleaning machines

without a solvent/air interface:

TR02DE94.000

TR02DE94.001

where:

Ei=the total halogenated HAP solvent emissions from the solvent

cleaning machine during the most recent monthly reporting period i,

(kilograms of solvent per square meter of solvent/air interface area

per month).

En=the total halogenated HAP solvent emissions from the solvent

cleaning machine during the most recent monthly reporting period i,

(kilograms of solvent per month).

SAi=the total amount of halogenated HAP liquid solvent added to

the solvent cleaning machine during the most recent monthly reporting

period i, (kilograms of solvent per month).

LSRi=the total amount of halogenated HAP liquid solvent removed

from the solvent cleaning machine during the most recent monthly

reporting period i, (kilograms of solvent per month).

SSRi=the total amount of halogenated HAP solvent removed from the

solvent cleaning machine in solid waste, obtained as described in

paragraph (c)(2) of this section, during the most recent monthly

reporting period i, (kilograms of solvent per month).

AREAi=the solvent/air interface area of the solvent cleaning

machine (square meters).

(2) Determine SSRi using the method specified in paragraph

(c)(2)(i) or (c)(2)(ii) of this section.

(i) From tests conducted using EPA reference method 25d.

(ii) By engineering calculations included in the compliance report.

(3) Determine the monthly rolling average, EA, for the 3-month

period ending with the most recent reporting period using equation 4

for cleaning machines with a solvent/air interface or equation 5 for

cleaning machines without a solvent/air interface:

TR02DE94.002

TR02DE94.003

Where:

EAi=the average halogenated HAP solvent emissions over the

preceding 3 monthly reporting periods, (kilograms of solvent per square

meter of solvent/air interface area per month).

EAn=the average halogenated HAP solvent emissions over the

preceding 3 monthly reporting periods (kilograms of solvent per month).

Ei=halogenated HAP solvent emissions for each month (j) for the

most recent 3 monthly reporting periods (kilograms of solvent per

square meter of solvent/air interface area).

En=halogenated HAP solvent emissions for each month (j) for the

most recent 3 monthly reporting periods (kilograms of solvent per

month).

j=1 = the most recent monthly reporting period.

j=2 = the monthly reporting period immediately prior to j=1.

j=3 = the monthly reporting period immediately prior to j=2.

(d) Each owner or operator of a batch vapor or in-line solvent

cleaning machine using a dwell to comply with Sec. 63.463 shall

determine the appropriate dwell time for each part or parts basket

using the procedure specified in paragraphs (d)(1) and (d)(2) of this

section.

(1) Determine the amount of time for the part or parts basket to

cease dripping once placed in the vapor zone. The part or parts basket

used for this determination must be at room temperature before being

placed in the vapor zone.

(2) The proper dwell time for parts to remain in the freeboard area

above the vapor zone is no less than 35 percent of the time determined

in paragraph (d)(1) of this section.

(e) An owner or operator of a source shall determine their

potential to emit from all solvent cleaning operations, using the

procedures described in paragraphs (e)(1) through (e)(3) of this

section. A facility's total potential to emit is the sum of the HAP

emissions from all solvent cleaning operations, plus all HAP emissions

from other sources within the facility.

(1) Determine the potential to emit for each individual solvent

cleaning using equation 6.

PTEi=Hi x Wi x SAIi (6)

Where:

PTEi=the potential to emit for solvent cleaning machine i

(kilograms of solvent per year).

Hi=hours of operation for solvent cleaning machine i (hours per

year).

=8760 hours per year, unless otherwise restricted by a Federally

enforceable requirement.

Wi=the working mode uncontrolled emission rate (kilograms per

square meter per hour).

=1.95 kilograms per square meter per hour for batch vapor and cold

cleaning machines.

=1.12 kilograms per square meter per hour for in-line cleaning

machines.

SAIi = solvent/air interface area of solvent cleaning machine i

(square meters). Section 63.461 defines the solvent/air interface area

for those machines that have a solvent/air interface. Cleaning machines

that do not have a solvent/air interface shall calculate a solvent/air

interface area using the procedure in paragraph (e)(2) of this section.

(2) Cleaning machines that do not have a solvent/air interface

shall calculate a solvent/air interface area using equation 7.

SAI=2.20 * (Vol)0.6 (7)

Where:

SAI=the solvent/air interface area (square meters).

Vol=the cleaning capacity of the solvent cleaning machine (cubic

meters).

(3) Sum the PTEi for all solvent cleaning operations to obtain

the total potential to emit for solvent cleaning operations at the

facility.

Sec. 63.466 Monitoring procedures.

(a) Except as provided in paragraph (g) of this section, each owner

or operator of a batch vapor or in-line solvent cleaning machine

complying with the equipment standards in Sec. 63.463 (b)(1)(i),

(b)(2)(i), (c)(1)(i), or (c)(2)(i) shall conduct monitoring and record

the results on a weekly basis for the control devices, as appropriate,

specified in paragraphs (a)(1) and (a)(2) of this section.

(1) If a freeboard refrigeration device is used to comply with

these standards, the owner or operator shall use a thermometer or

thermocouple to measure the temperature at the center of the air

blanket during the idling mode.

(2) If a superheated vapor system is used to comply with these

standards, the owner or operator shall use a thermometer or

thermocouple to measure the temperature at the center of the

superheated solvent vapor zone while the solvent cleaning machine is in

the idling mode.

(b) Except as provided in paragraph (g) of this section, each owner

or operator of a batch vapor or in-line solvent cleaning machine

complying with the equipment standards of Sec. 63.463 (b)(1)(i),

(b)(2)(i), (c)(1)(i), or (c)(2)(i) shall conduct monitoring and record

the results on a monthly basis for the control devices, as appropriate,

specified in paragraphs (b)(1) and (b)(2) of this section.

(1) If a cover (working-mode, downtime-mode, and/or idling-mode

cover) is used to comply with these standards, the owner or operator

shall conduct a visual inspection to determine if the cover is opening

and closing properly, completely covers the cleaning machine openings

when closed, and is free of cracks, holes, and other defects.

(2) If a dwell is used, the owner or operator shall determine the

actual dwell time by measuring the period of time that parts are held

within the freeboard area of the solvent cleaning machine after

cleaning.

(c) Except as provided in paragraph (g) of this section, each owner

or operator of a batch vapor or in-line solvent cleaning machine

complying with the equipment or idling standards in Sec. 63.463 shall

monitor the hoist speed as described in paragraphs (c)(1) through

(c)(4) of this section.

(1) The owner or operator shall determine the hoist speed by

measuring the time it takes for the hoist to travel a measured

distance. The speed is equal to the distance in meters divided by the

time in minutes (meters per minute).

(2) The monitoring shall be conducted monthly. If after the first

year, no exceedances of the hoist speed are measured, the owner or

operator may begin monitoring the hoist speed quarterly.

(3) If an exceedance of the hoist speed occurs during quarterly

monitoring, the monitoring frequency returns to monthly until another

year of compliance without an exceedance is demonstrated.

(4) If an owner or operator can demonstrate to the Administrator's

satisfaction in the initial compliance report that the hoist cannot

exceed a speed of 3.4 meters per minute (11 feet per minute), the

required monitoring frequency is quarterly, including during the first

year of compliance.

(d) Except as provided in paragraph (g) of this section, each owner

or operator of a batch vapor or in-line solvent cleaning machine

complying with the equipment standards in Sec. 63.463 (b)(1)(i),

(b)(2)(i), (c)(1)(i), or (c)(2)(i) using a reduced room draft shall

conduct monitoring and record the results as specified in

paragraph(d)(1) or (d)(2) of this section.

(1) If the reduced room draft is maintained by controlling room

parameters (i.e., redirecting fans, closing doors and windows, etc.),

the owner or operator shall conduct an initial monitoring test of the

windspeed and of room parameters, quarterly monitoring of windspeed,

and weekly monitoring of room parameters as specified in paragraphs

(d)(1)(i) and (d)(1)(ii) of this section.

(i) Measure the windspeed within 6 inches above the top of the

freeboard area of the solvent cleaning machine using the procedure

specified in paragraphs (d)(1)(i)(A) through (d)(1)(i)(D) of this

section.

(A) Determine the direction of the wind current by slowly rotating

a velometer or similar device until the maximum speed is located.

(B) Orient a velometer in the direction of the wind current at each

of the four corners of the machine.

(C) Record the reading for each corner.

(D) Average the values obtained at each corner and record the

average wind speed.

(ii) Monitor on a weekly basis the room parameters established

during the initial compliance test that are used to achieve the reduced

room draft.

(2) If an enclosure (full or partial) is used to achieve a reduced

room draft, the owner or operator shall conduct an initial monitoring

test and, thereafter, monthly monitoring tests of the windspeed within

the enclosure using the procedure specified in paragraphs (d)(2)(i) and

(d)(2)(ii) of this section and a monthly visual inspection of the

enclosure to determine if it is free of cracks, holes and other

defects.

(i) Determine the direction of the wind current in the enclosure by

slowly rotating a velometer inside the entrance to the enclosure until

the maximum speed is located.

(ii) Record the maximum wind speed.

(e) Except as provided in paragraph (g) of this section, each owner

or operator using a carbon adsorber to comply with this subpart shall

measure and record the concentration of halogenated HAP solvent in the

exhaust of the carbon adsorber weekly with a colorimetric detector

tube. This test shall be conducted while the solvent cleaning machine

is in the working mode and is venting to the carbon adsorber. The

exhaust concentration shall be determined using the procedure specified

in paragraphs (e)(1) through (e)(3) of this section.

(1) Use a colorimetric detector tube designed to measure a

concentration of 100 parts per million by volume of solvent in air to

an accuracy of 25 parts per million by volume.

(2) Use the colorimetric detector tube according to the

manufacturer's instructions.

(3) Provide a sampling port for monitoring within the exhaust

outlet of the carbon adsorber that is easily accessible and located at

least 8 stack or duct diameters downstream from any flow disturbance

such as a bend, expansion, contraction, or outlet; downstream from no

other inlet; and 2 stack or duct diameters upstream from any flow

disturbance such as a bend, expansion, contraction, inlet or outlet.

(f) Each owner or operator of a batch vapor or in-line solvent

cleaning machine complying with the idling emission limit standards of

Sec. 63.463 (b)(1)(ii), (b)(2)(ii), (c)(1)(ii), or (c)(2)(ii) shall

comply with the requirements specified in paragraphs (f)(1) and (f)(2)

of this section.

(1) If using controls listed in paragraphs (a) through (e) of this

section, the owner or operator shall comply with the monitoring

frequency requirements in paragraphs (a) through (e) of this section.

(2) If using controls not listed in paragraphs (a) through (e) of

this section, the owner or operator shall establish the monitoring

frequency for each control and submit it to the Administrator for

approval in the initial test report.

(g) Each owner or operator using a control device listed in

paragraphs (a) through (e) of this section can use alternative

monitoring procedures approved by the Administrator.

Sec. 63.467 Recordkeeping requirements.

(a) Each owner or operator of a batch vapor or in-line solvent

cleaning machine complying with the provisions of Sec. 63.463 shall

maintain records in written or electronic form specified in paragraphs

(a)(1) through (a)(5) of this section for the lifetime of the machine.

(1) Owner's manuals, or if not available, written maintenance and

operating procedures, for the solvent cleaning machine and control

equipment.

(2) The date of installation for the solvent cleaning machine and

all of its control devices. If the exact date for installation is not

known, a letter certifying that the cleaning machine and its control

devices were installed prior to, or on, November 29, 1993, or after

November 29, 1993, may be substituted.

(3) If a dwell is used to comply with these standards, records of

the tests required in Sec. 63.465(d) to determine an appropriate dwell

time for each part or parts basket.

(4) Each owner or operator of a batch vapor or in-line solvent

cleaning machine complying with the idling emission limit standards of

Sec. 63.463(b)(1)(ii), (b)(2)(ii), (c)(1)(ii), or (c)(2)(ii) shall

maintain records of the initial performance test, including the idling

emission rate and values of the monitoring parameters measured during

the test.

(5) Records of the halogenated HAP solvent content for each solvent

used in a solvent cleaning machine subject to the provisions of this

subpart.

(b) Each owner or operator of a batch vapor or in-line solvent

cleaning machine complying with Sec. 63.463 shall maintain records

specified in paragraphs (b)(1) through (b)(4) of this section either in

electronic or written form for a period of 5 years.

(1) The results of control device monitoring required under

Sec. 63.466.

(2) Information on the actions taken to comply with Sec. 63.463(e)

and (f). This information shall include records of written or verbal

orders for replacement parts, a description of the repairs made, and

additional monitoring conducted to demonstrate that monitored

parameters have returned to accepted levels.

(3) Estimates of annual solvent consumption for each solvent

cleaning machine.

(4) If a carbon adsorber is used to comply with these standards,

records of the date and results of the weekly measurement of the

halogenated HAP solvent concentration in the carbon adsorber exhaust

required in Sec. 63.466(e).

(c) Each owner or operator of a batch vapor or in-line solvent

cleaning machine complying with the provisions of Sec. 63.464 shall

maintain records specified in paragraphs (c)(1) through (c)(3) of this

section either in electronic or written form for a period of 5 years.

(1) The dates and amounts of solvent that are added to the solvent

cleaning machine.

(2) The solvent composition of wastes removed from cleaning

machines as determined using the procedure described in

Sec. 63.465(c)(2).

(3) Calculation sheets showing how monthly emissions and the

rolling 3-month average emissions from the solvent cleaning machine

were determined, and the results of all calculations.

(d) Each owner or operator of a solvent cleaning machine without a

solvent/air interface complying with the provisions of Sec. 63.464

shall maintain records on the method used to determine the cleaning

capacity of the cleaning machine.

Sec. 63.468 Reporting requirements.

(a) Each owner or operator of an existing solvent cleaning machine

subject to the provisions of this subpart shall submit an initial

notification report to the Administrator no later than August 29, 1995.

This report shall include the information specified in paragraphs

(a)(1) through (a)(6) of this section.

(1) The name and address of the owner or operator.

(2) The address (i.e., physical location) of the solvent cleaning

machine(s).

(3) A brief description of each solvent cleaning machine including

machine type (batch vapor, batch cold, vapor in-line or cold in-line),

solvent/air interface area, and existing controls.

(4) The date of installation for each solvent cleaning machine or a

letter certifying that the solvent cleaning machine and its control

devices were installed prior to, or after, November 29, 1993.

(5) The anticipated compliance approach for each solvent cleaning

machine.

(6) An estimate of annual halogenated HAP solvent consumption for

each solvent cleaning machine.

(b) Each owner or operator of a new solvent cleaning machine

subject to the provisions of this subpart shall submit an initial

notification report to the Administrator. New sources for which

construction or reconstruction had commenced and initial startup had

not occurred before December 2, 1994, shall submit this report as soon

as practicable before startup but no later than January 31, 1995. New

sources for which the construction or reconstruction commenced after

December 2, 1994, shall submit this report as soon as practicable

before the construction or reconstruction is planned to commence. This

report shall include all of the information required in Sec. 63.5(d)(1)

of subpart A (General Provisions), with the revisions and additions in

paragraphs (b)(1) through (b)(3) of this section.

(1) The report shall include a brief description of each solvent

cleaning machine including machine type (batch vapor, batch cold, vapor

in-line, or cold-line), solvent/air interface area, and existing

controls.

(2) The report shall include the anticipated compliance approach

for each solvent cleaning machine.

(3) In lieu of Sec. 63.5(d)(1)(ii)(H) of subpart A of this part,

the owner or operator must report an estimate of annual halogenated HAP

solvent consumption for each solvent cleaning machine.

(c) Each owner or operator of a batch cold solvent cleaning machine

subject to the provisions of this subpart shall submit a compliance

report to the Administrator. For existing sources, this report shall be

submitted to the Administrator no later than 150 days after the

compliance date specified in Sec. 63.460(d). For new sources, this

report shall be submitted to the Administrator no later than 150 days

after startup or May 1, 1995, whichever is later. This report shall

include the requirements specified in paragraphs (c)(1) through (c)(4)

of this section.

(1) The name and address of the owner or operator.

(2) The address (i.e., physical location) of the solvent cleaning

machine(s).

(3) A statement, signed by the owner or operator of the solvent

cleaning machine, stating that the solvent cleaning machine for which

the report is being submitted is in compliance with the provisions of

this subpart.

(4) The compliance approach for each solvent cleaning machine.

(d) Each owner or operator of a batch vapor or in-line solvent

cleaning machine complying with the provisions of Sec. 63.463 shall

submit to the Administrator an initial statement of compliance for each

solvent cleaning machine. For existing sources, this report shall be

submitted to the Administrator no later than 150 days after the

compliance date specified in Sec. 63.460(d). For new sources, this

report shall be submitted to the Administrator no later than 150 days

after startup or May 1, 1995, whichever is later. This statement shall

include the requirements specified in paragraphs (d)(1) through (d)(6)

of this section.

(1) The name and address of the owner or operator.

(2) The address (i.e., physical location) of the solvent cleaning

machine(s).

(3) A list of the control equipment used to achieve compliance for

each solvent cleaning machine.

(4) For each piece of control equipment required to be monitored, a

list of the parameters that are monitored and the values of these

parameters measured on or during the first month after the compliance

date.

(5) Conditions to maintain the wind speed requirements of

Sec. 63.463(e)(2)(ii), if applicable.

(6) Each owner or operator of a solvent cleaning machine complying

with the idling emission limit standards of Sec. 63.463(b)(1)(ii),

(b)(2)(ii), (c)(1)(ii), and (c)(2)(ii) shall submit a test report for

tests of idling emissions meeting the specifications in Method 307 of

appendix A to this subpart. This report shall comply with the

requirements specified in paragraphs (d)(6)(i) through (d)(6)(iv) of

this section.

(i) This test must be on the same specific model cleaner used at

the source. The test can be done by the owner or operator of the

affected machine or can be supplied by the vendor of that solvent

cleaning machine or a third party.

(ii) This report must clearly state the monitoring parameters,

monitoring frequency and the delineation of exceedances for each

parameter.

(iii) If a solvent cleaning machine vendor or third party test

report is used to demonstrate compliance, it shall include the

following for the solvent cleaning machine tested: Name of person(s) or

company that performed the test, model name, the date the solvent

cleaning machine was tested, serial number, and a diagram of the

solvent cleaning machine tested.

(iv) If a solvent cleaning machine vendor or third party test

report is used, the owner or operator of the solvent cleaning machine

shall comply with the requirements specified in either paragraphs

(d)(6)(iv)(A) and (d)(6)(iv)(B) of this section.

(A) Submit a statement by the solvent cleaning machine vendor that

the unit tested is the same as the unit the report is being submitted

for.

(B) Demonstrate to the Administrator's satisfaction that the

solvent emissions from the solvent cleaning machine for which the test

report is being submitted are equal to or less than the solvent

emissions from the solvent cleaning machine in the vendor test report.

(7) If a carbon adsorber is used to comply with these standards,

the date and results of the weekly measurement of the halogenated HAP

solvent concentration in the carbon adsorber exhaust required in

Sec. 63.466(e).

(e) Each owner or operator of a batch vapor or in-line solvent

cleaning machine complying with the provisions of Sec. 63.464 shall

submit to the Administrator an initial statement of compliance for each

solvent cleaning machine. For existing sources, this report shall be

submitted to the Administrator no later than 150 days after the

compliance date specified in Sec. 63.460(d). For new sources, this

report shall be submitted to the Administrator no later than 150 days

after startup or May 1, 1995, whichever is later. The statement shall

include the information specified in paragraphs (e)(1) through (e)(4)

of this section.

(1) The name and address of the solvent cleaning machine owner or

operator.

(2) The address of the solvent cleaning machine(s).

(3) The solvent/air interface area for each solvent cleaning

machine or, for cleaning machines without a solvent/air interface, a

description of the method used to determine the cleaning capacity and

the results.

(4) The results of the first 3-month average emissions calculation.

(f) Each owner or operator of a batch vapor or in-line solvent

cleaning machine complying with the provisions of Sec. 63.463 shall

submit an annual report by February 1 of the year following the one for

which the reporting is being made. This report shall include the

requirements specified in paragraphs (f)(1) through (f)(3) of this

section.

(1) A signed statement from the facility owner or his designee

stating that, ``All operators of solvent cleaning machines have

received training on the proper operation of solvent cleaning machines

and their control devices sufficient to pass the test required in

Sec. 63.463(d)(10).''

(2) An estimate of solvent consumption for each solvent cleaning

machine during the reporting period.

(3) The reports required under paragraphs (f) and (g) of this

section can be combined into a single report for each facility.

(g) Each owner or operator of a batch vapor or in-line solvent

cleaning machine complying with the provisions of Sec. 63.464 shall

submit a solvent emission report every year. This solvent emission

report shall contain the requirements specified in paragraphs (g)(1)

through (g)(4) of this section.

(1) The size and type of each unit subject to this subpart

(solvent/air interface area or cleaning capacity).

(2) The average monthly solvent consumption for the solvent

cleaning machine in kilograms per month.

(3) The 3-month monthly rolling average solvent emission estimates

calculated each month using the method as described in Sec. 63.465(c).

(4) The reports required under paragraphs (f) and (g) of this

section can be combined into a single report for each facility.

(h) Each owner or operator of a batch vapor or in-line solvent

cleaning machine shall submit an exceedance report to the Administrator

semiannually except when, the Administrator determines on a case-by-

case basis that more frequent reporting is necessary to accurately

assess the compliance status of the source or, an exceedance occurs.

Once an exceedance has occurred the owner or operator shall follow a

quarterly reporting format until a request to reduce reporting

frequency under paragraph (i) of this section is approved. Exceedance

reports shall be delivered or postmarked by the 30th day following the

end of each calendar half or quarter, as appropriate. The exceedance

report shall include the applicable information in paragraphs (h) (1)

through (3) of this section.

(1) Information on the actions taken to comply with Sec. 63.463 (e)

and (f). This information shall include records of written or verbal

orders for replacement parts, a description of the repairs made, and

additional monitoring conducted to demonstrate that monitored

parameters have returned to accepted levels.

(2) If an exceedance has occurred, the reason for the exceedance

and a description of the actions taken.

(3) If no exceedances of a parameter have occurred, or a piece of

equipment has not been inoperative, out of control, repaired, or

adjusted, such information shall be stated in the report.

(i) An owner or operator who is required to submit an exceedance

report on a quarterly (or more frequent) basis may reduce the frequency

of reporting to semiannual if the conditions in paragraphs (i)(1)

through (i)(3) of this section are met.

(1) The source has demonstrated a full year of compliance without

an exceedance.

(2) The owner or operator continues to comply with all relevant

recordkeeping and monitoring requirements specified subpart A (General

Provisions) and in this subpart.

(3) The Administrator does not object to a reduced frequency of

reporting for the affected source as provided in paragraph (e)(3)(iii)

of subpart A (General Provisions).

(j) The Administrator has determined, pursuant to the criteria

under section 502(a) of the Act, that an owner or operator of any batch

cold solvent cleaning machine that is not itself a major source and

that is not located at a major source, as defined under 40 CFR 70.2, is

exempt from part 70 permitting requirements for that source.

An owner or operator of any other solvent cleaning machine subject

to the provisions of this subpart is subject to part 70 permitting

requirements, such sources, if not major or located at major sources,

may be exempted by the State from applying for a part 70 permit until

42 months after the EPA first approves a part 70 program or such other

date established by the permitting authority that assures that such

sources obtain a permit by 5 years after the EPA first approves a part

70 program.

(k) Each owner or operator of a solvent cleaning machine requesting

an equivalency determination, as described in Sec. 63.469 shall submit

an equivalency request report to the Administrator. For existing

sources, this report must be submitted to the Administrator no later

than June 3, 1996. For new sources, this report must be submitted and

approved by the Administrator prior to startup.

Sec. 63.469 Equivalent methods of control.

Upon written application, the Administrator may approve the use of

equipment or procedures after they have been satisfactorily

demonstrated to be equivalent, in terms of reducing emissions of

methylene chloride, perchloroethylene, trichloroethylene, 1,1,1-

trichloroethane, carbon tetrachloride or chloroform to the atmosphere,

to those prescribed for compliance within a specified paragraph of this

subpart. The application must contain a complete description of the

equipment or procedure and the proposed equivalency testing procedure

and the date, time, and location scheduled for the equivalency

demonstration.

3. Appendix A is amended by adding Method 307 to read as follows:

Appendix A to Part 63--Test Methods

* * * * *

Method 307--Determination of Emissions From Halogenated Solvent Vapor

Cleaning Machines Using a Liquid Level Procedure

1. Applicability and Principle

1.1 Applicability. This method is applicable to the

determination of the halogenated solvent emissions from solvent

vapor cleaners in the idling mode.

1.2 Principle. The solvent level in the solvent cleaning

machine is measured using inclined liquid level indicators. The

change in liquid level corresponds directly to the amount of solvent

lost from the solvent cleaning machine.

2. Apparatus

Note: Mention of trade names or specific products does not

constitute endorsement by the Environmental Protection Agency.

2.1 Inclined Liquid Level Indicator. A schematic of the

inclined liquid level indicators used in this method is shown in

figure 307-1; two inclined liquid level indicators having 0.05

centimeters divisions or smaller shall be used. The liquid level

indicators shall be made of glass, Teflon, or any similar material

that will not react with the solvent being used. A 6-inch by 1-inch

slope is recommended; however the slope may vary depending on the

size and design of the solvent cleaning machine.

Note: It is important that the inclined liquid level indicators

be constructed with ease of reading in mind. The inclined liquid

level indicators should also be mounted so that they can be raised

or lowered if necessary to suit the solvent cleaning machine size.

BILLING CODE 6560-50-P

TR02DE94.004

BILLING CODE 6560-50-C

2.2 Horizontal Indicator. Device to check the inclined liquid

level indicators orientation relative to horizontal.

2.3 Velocity Meter. Hotwire and vane anemometers, or other

devices capable of measuring the flow rates ranging from 0 to 15.2

meters per minute across the solvent cleaning machine.

3. Procedure

3.1 Connection of the Inclined Liquid Level Indicator. Connect

one of the inclined liquid level indicators to the boiling sump

drain and the other inclined liquid level indicator to the immersion

sump drain using Teflon tubing and the appropriate fittings. A

schematic diagram is shown in figure 307-2.

BILLING CODE 6560-50-P

TR02DE94.005

BILLING CODE 6560-50-C

3.2 Positioning of Velocity Meter. Position the velocity meter

so that it measures the flow rate of the air passing directly across

the solvent cleaning machine.

3.3 Level the Inclined Liquid Level Indicators.

3.4 Initial Inclined Liquid Level Indicator Readings. Open the

sump drainage valves. Allow the solvent cleaning machine to operate

long enough for the vapor zone to form and the system to stabilize

(check with manufacturer). Record the inclined liquid level

indicators readings and the starting time on the data sheet. A

sample data sheet is provided in figure 307-3.

Date-------------------------------------------------------------------

Run--------------------------------------------------------------------

Solvent type-----------------------------------------------------------

Solvent density, g/m\3\ (lb/ft\3\)-------------------------------------

Length of boiling sump (SB), m (ft)-------------------------------

Width of boiling sump (WB), m (ft)--------------------------------

Length of immersion sump (SI), m (ft)-----------------------------

Width of immersion sump (WI), m (ft)------------------------------

Length of solvent vapor/air interface (SV), m (ft) ____________

Width of solvent vapor/air interface (WV), m (ft) ____________

------------------------------------------------------------------------

Boiling Immersion

Clock time sump sump Flow rate

reading reading reading

------------------------------------------------------------------------

------------------------------------------------------------------------

Figure 307-3. Data sheet.

3.5 Final Inclined Liquid Level Indicator Readings. At the end

of the 16-hour test run, check to make sure the inclined liquid

level indicators are level; if not, make the necessary adjustments.

Record the final inclined liquid level indicators readings and time.

3.6 Determination of Solvent Vapor/Air Interface Area for Each

Sump. Determine the area of the solvent/air interface of the

individual sumps. Whenever possible, physically measure these

dimensions, rather than using factory specifications. A schematic of

the dimensions of a solvent cleaning machine is provided in figure

307-4.

BILLING CODE 6560-50-P

TR02DE94.006

BILLING CODE 6560-50-C

4. Calculations

4.1 Nomenclature.

AB = area of boiling sump interface, m\2\ (ft\2\).

AI = area of immersion sump interface, m\2\ (ft\2\).

AV = area of solvent/air interface, m\2\ (ft\2\).

E = emission rate, kg/m\2\-hr (lb/ft\2\-hr).

K = 100,000 cm . g/m . kg for metric units.

= 12 in./ft for English units.

LBF = final boiling sump inclined liquid level indicators

reading, cm (in.).

LBi = initial boiling sump inclined liquid level indicators

reading, cm (in.).

LIf = final immersion sump inclined liquid level indicators

reading, cm (in.).

LIi = initial immersion sump inclined liquid level indicators

reading, cm (in.).

SB = length of the boiling sump, m (ft).

SI = length of the immersion sump, m (ft).

SV = length of the solvent vapor/air interface, m (ft).

WB = width of the boiling sump, m (ft).

WI = width of the immersion sump, m (ft).

WV = width of the solvent vapor/air interface, m (ft).

= density of solvent, g/m3 (lb/ft3).

= test time, hr.

4.2 Area of Sump Interfaces. Calculate the areas of the boiling

and immersion sump interfaces as follows:

AB = SB WB Eq. 307-1

AI = SI WI Eq. 307-2

4.3 Area of Solvent/Air Interface. Calculate the area of the

solvent vapor/air interface as follows:

AV = SV WV Eq. 307-3

4.4 Emission Rate. Calculate the emission rate as follows:

TR02DE94.007

4. Appendix B to Part 63 is revised to read as follows:

Appendix B--Test of Solvent Cleaning Procedures

General Questions

______ 1. What is the maximum allowable speed for parts entry and

removal?

A. 8.5 meters per minute (28 feet per minute).

B. 3.4 meters per minute (11 feet per minute).

C. 11 meters per minute (36 feet per minute).

D. No limit.

______ 2. How do you ensure that parts enter and exit the solvent

cleaning machine at the speed required in the regulation?

A. Program on computerized hoist monitors speed.

B. Can judge the speed by looking at it.

C. Measure the time it takes the parts to travel a measured

distance.

______ 3. Identify the sources of air disturbances.

A. Fans

B. Open doors

C. Open windows

D. Ventilation vents

E. All of the above

______ 4. What are the three operating modes?

A. Idling, working and downtime

B. Precleaning, cleaning, and drying

C. Startup, shutdown, off

D. None of the above

______ 5. When can parts or parts baskets be removed from the

solvent cleaning machine?

A. When they are clean

B. At any time

C. When dripping stops

D. Either A or C is correct

______ 6. How must parts be oriented during cleaning?

A. It does not matter as long as they fit in the parts basket.

B. So that the solvent pools in the cavities where the dirt is

concentrated.

C. So that solvent drains from them freely.

______ 7. During startup, what must be turned on first, the primary

condenser or the sump heater?

A. Primary condenser

B. Sump heater

C. Turn both on at same time

D. Either A or B is correct

______ 8. During shutdown, what must be turned off first, the

primary condenser or the sump heater?

A. Primary condenser

B. Sump heater

C. Turn both off at same time

D. Either A or B is correct

______ 9. In what manner must solvent be added to and removed from

the solvent cleaning machine?

A. With leak proof couplings

B. With the end of the pipe in the solvent sump below the liquid

solvent surface.

C. So long as the solvent does not spill, the method does not

matter.

D. A and B

______ 10. What must be done with waste solvent and still and sump

bottoms?

A. Pour down the drain

B. Store in closed container

C. Store in a bucket

D. A or B

______ 11. What types of materials are prohibited from being cleaned

in solvent cleaning machines using halogenated HAP solvents?

A. Sponges

B. Fabrics

C. Paper

D. All of the above

Control Device Specific Questions

[ ] Freeboard Refrigeration Device

______ 1. What temperature must the FRD achieve?

A. Below room temperature

B. 50 deg.F

C. Below the solvent boiling point

D. 30 percent below the solvent boiling point

[ ] Working-Mode Cover

______ 2. When can a cover be open?

A. While parts are in the cleaning machine

B. During parts entry and removal

C. During maintenance

D. During measurements for compliance purposes

E. A and C

F. B, C, and D

______ 3. Covers must be maintained in what condition?

A. Free of holes

B. Free of cracks

C. So that they completely seal cleaner opening

D. All of the above

[ ] Dwell

______ 4. Where must the parts be held for the appropriate dwell

time?

A. In the vapor zone

B. In the freeboard area above the vapor zone

C. Above the cleaning machine

D. In the immersion sump

Answers

General Questions

1. B

2. A or C

3. E

4. A

5. C

6. C

7. A

8. B

9. D

10. B

11. D

Control Device Specific Questions

1. D

2. F

3. D

4. B

5. Appendix C is added to Part 63 to read as follows:

Appendix C--General Provisions Applicability to Subpart T

----------------------------------------------------------------------------------------------------------------

Applies to subpart T

Reference ---------------------------- Comments

BCC BVI

----------------------------------------------------------------------------------------------------------------

63.1(a) (1)-(3).............. Yes......... Yes.........

63.1(a)(4)................... Yes......... Yes......... Subpart T (this appendix) specifies applicability of

each paragraph in subpart A to subpart T.

63.1(a)(5)................... No.......... No..........

63.1(a) (6)-(8).............. Yes......... Yes.........

63.1(a)(9)................... No.......... No..........

63.1(a)(10).................. Yes......... Yes.........

63.1(a)(11).................. No.......... No.......... Subpart T allows submittal of notifications and

reports through the U.S. mail, fax, and courier.

Subpart T requires that the postmark for

notifications and reports submitted through the U.S.

mail or other non-Governmental mail carriers be on

or before deadline specified in an applicable

requirement.

63.1(a) (12)-(14)............ Yes......... Yes.........

63.1(b)(1)................... No.......... No.......... Subpart T specifies applicability.

63.1(b)(2)................... No.......... Yes.........

63.1(b)(3)................... No.......... No.......... Subpart T requires that a record of halogenated

cleaning machine applicability determination be kept

on site for 5 years, or until the cleaning machine

changes its operations. The record shall be

sufficiently detailed to allow the Administrator to

make a finding about the source's applicability

status with regard to subpart T.

63.1(c)(1)................... Yes......... Yes.........

63.1(c)(2)................... Yes......... Yes......... Subpart T, section 63.46(8)(h), indicates a Title V

permit exemption for halogenated HAP batch cold

solvent cleaning machines that are not major sources

and not located at a major source. This section also

specifies a deferral from the requirement of a Title

V permit for owners or operators of solvent cleaning

machines subject to subpart T provisions, other than

halogenated HAP batch cold solvent cleaning

machines, that are not major sources, and not

located at a major source.

63.1(c)(3)................... No.......... No..........

63.1(c)(4)................... Yes......... Yes.........

63.1(c)(5)................... Yes......... Yes......... Subpart T does not require continuous monitoring

systems (CMS) or continuous opacity monitoring

systems. Therefore, notifications and requirements

for CMS and COMS specified in subpart A do not apply

to subpart T.

63.1(d)...................... No.......... No..........

63.1(e)...................... No.......... Yes.........

63.2......................... Yes......... Yes......... Subpart T definitions (section 63.461) for existing

and new overlap with the definitions for existing

source and new source in subpart A (section 63.2).

Both subpart A and T also define Administrator.

63.3(a)-(c).................. Yes......... Yes.........

63.4(a) (1)-(3).............. Yes......... Yes.........

63.4(a)(4)................... No.......... No..........

63.4(a)(5)................... Yes......... Yes.........

63.4(b)-(c).................. Yes......... Yes.........

63.5(a)(1)................... Yes......... Yes.........

63.5(a)(2)................... Yes......... Yes.........

63.5(b)(1)................... Yes......... Yes.........

63.5(b)(2)................... No.......... No..........

63.5(b)(3)................... No.......... No.......... Subpart T overrides the requirement for approval

prior to constructing a new or reconstructing an

existing major source.

63.5(b)(4)-(6)............... Yes......... Yes.........

63.5(c)...................... No.......... No..........

63.5 (d)-(f)................. No.......... No.......... Subpart T overrides the requirement to submit an

application for approval of construction or

reconstruction of a halogenated solvent cleaning

machine.

63.6(a)...................... Yes......... Yes.........

63.6(b) (1)-(5).............. Yes......... Yes......... Subpart T, section 63.460, specifies compliance

dates.

63.6(b)(6)................... No.......... No..........

63.6(b)(7)................... No.......... No.......... Subpart T has the same requirements for affected

halogenated HAP solvent cleaning machine

subcategories that are located at area sources as it

does for those located at major sources.

63.6(c)(1)-(2)............... Yes......... Yes......... Subpart T allows 3 years from the date of

promulgation for both area and major existing

sources to comply.

63.6(c) (3)-(4).............. No.......... No..........

63.6(c)(5)................... Yes......... Yes......... Subpart T has the same requirements for affected

halogenated HAP solvent cleaning machine

subcategories that are located at area sources as it

does for those located at major sources.

Subpart T allows 3 years from the date of

promulgation for both area and major existing

sources to comply.

63.6(d)...................... No.......... No..........

63.6(e)(1)-(2)............... Yes......... Yes.........

63.6(e)(3)................... No.......... No.......... Subpart T overrides the requirement of a startup,

shutdown, and malfunction plan. Subpart T specifies

startup and shutdown procedures to be followed by an

owner or operator for batch vapor and in-line

cleaning machines.

63.6(f)-(g).................. Yes......... Yes.........

63.6(h)...................... No.......... No.......... Subpart T does not require compliance with an opacity

or visible emission standard.

63.6(i) (1)-(14)............. Yes......... Yes.........

63.6(i)(15).................. No.......... No..........

63.6(i)(16).................. Yes......... Yes.........

63.6(j)...................... Yes......... Yes.........

63.7(a)...................... No.......... Yes......... Subpart T gives owners or operators the option to

perform an idling emission performance test as a way

of demonstrating compliance. Other options are also

available that do not require a performance test.

63.7(b)...................... No.......... Yes......... This is only required for those owners or operators

that choose the idling emission standard as their

compliance option.

63.7(c)(1)................... No.......... Yes......... This is only required for those owners or operators

that choose the idling emission standard as their

compliance option.

63.7(c) (2)-(3).............. No.......... No.......... Subpart T does not require a site-specific test plan

for the idling emission performance test.

63.7(c)(4)................... No.......... No.......... Subpart T does not require a performance test that

involves the retrieval of gas samples, and therefore

this does not apply.

63.7(d)...................... No.......... No.......... Requirements do not apply to the idling emission

performance test option.

63.7(e)...................... No.......... Yes.........

63.7(f)...................... No.......... Yes.........

63.7(g)...................... No.......... Yes......... Subpart T specifies what is required to demonstrate

idling emission standard compliance through the use

of the Environmental Protection Agency test method

307 and control device monitoring. Reports and

records of testing and monitoring are required for

compliance verification. Three runs of the test are

required for compliance, as specified in section

63.7(e) of subpart A.

63.7(h)...................... No.......... No.......... Subpart T does not require the use of a performance

test to comply with the standard. The idling

emission standard option (which requires an idling

emission performance test) is an alternative option

offered to owners or operators of batch vapor and in-

line cleaning machines for compliance flexibility.

63.8 (a)-(b)................. Yes......... Yes.........

63.8 (c)-(e)................. No.......... No.......... Subpart T does not require the use of continuous

monitoring systems to demonstrate compliance.

63.8(f)...................... Yes......... Yes.........

63.8(g)...................... No.......... No.......... Subpart T does not require continuous opacity

monitoring systems and continuous monitoring systems

data.

63.9(a) (1)-(4).............. Yes......... Yes.........

63.9(b)(1)................... Yes......... Yes.........

63.9(b)(2)................... Yes......... Yes......... Subpart T includes all of those requirements stated

in subpart A, except that subpart A also requires a

statement as to whether the affected source is a

major or an area source, and an identification of

the relevant standard (including the source's

compliance date). Subpart T also has some more

specific information requirements specific to the

affected source (see subpart T, sections 63.468(a)-

(b)).

63.9(b)(3)................... Yes......... Yes......... The subpart A and subpart T initial notification

reports differ (see above).

63.9(b)(4)................... No.......... No.......... Subpart T does not require an application for

approval of construction or reconstruction.

63.9(b)(5)................... Yes......... Yes......... .....................................................

63.9(c)...................... Yes......... Yes......... .....................................................

63.9(d)...................... Yes......... Yes......... .....................................................

63.9(e)...................... Yes......... Yes......... Under subpart T, this requirement only applies to

owners or operators choosing to comply with the

idling emissions standard.

63.9(f)...................... No.......... No.......... Subpart T does not require opacity or visible

emission observations.

63.9(g)(1)................... No.......... No.......... Subpart T does not require the use of continuous

monitoring systems or continuous opacity monitoring

systems.

63.9(h)...................... No.......... No.......... Section 63.468 of subpart T requires an initial

statement of compliance for existing sources to be

submitted to the Administrator no later than 150

days after the compliance date specified in section

63.460(d) of subpart T. For new sources, this report

is to be submitted to the Administrator no later

than 150 days from the date specified in section

63.460(c).

63.9(i)...................... Yes......... Yes.........

63.9(j)...................... Yes......... Yes.........

63.10(a)..................... Yes......... Yes.........

63.10(b)..................... No.......... No.......... Recordkeeping requirements are specified in subpart

T.

63.10(c) (1)-(15)............ No.......... No.......... Subpart T does not require continuous monitoring

systems.

63.10(d)(1).................. Yes......... Yes.........

63.10(d)(2).................. No.......... No.......... Reporting requirements are specified in subpart T.

63.10(e) (l)-(2)............. No.......... No.......... Subpart T does not require continuous emissions

monitoring systems.

63.10(e)(3).................. No.......... No.......... Subpart T does not require continuous monitoring

systems.

63.10(e)(4).................. No.......... No.......... Subpart T does not require continuous opacity

monitoring systems.

63.10(f)..................... Yes......... Yes.........

63.11(a)..................... Yes......... Yes.........

63.11(b)..................... No.......... No.......... Flares are not a control option under subpart T.

63.12 (a)-(c)................ Yes......... Yes.........

63.13 (a)-(c)................ Yes......... Yes.........

63.14........................ No.......... No.......... Subpart T requirements do not require the use of the

test methods incorporated by reference in subpart A.

63.15(a)-(b)................. Yes......... Yes.........

----------------------------------------------------------------------------------------------------------------

BCC=Batch Cold Cleaning Machines.

BVI=Batch Vapor and In-line Cleaning Machines.

[FR Doc. 94-28974 Filed 12-01-94; 8:45 am]

BILLING CODE 6560-50-P

This is a copy of a public record, reproduced as it was published. It is not legal advice, and it may not be the version a court would rely on. Check the official source before you cite it.

A word about cookies

We need a few to keep you signed in and the library working. The rest help us see which pages people use and where they get stuck. They stay off unless you say yes.

National Emission Standards for Hazardous Air Pollutants: Halogenated Solvent Cleaning | Frix