Hybrid PFD's; Establishment of Approval Requirements
Federal RegisterJan 18, 1994
Ask Donna
What actually matters in this document.
Text
DEPARTMENT OF TRANSPORTATION
Coast Guard
46 CFR Parts 25 and 160
[CGD 78-174]
RIN 2115-AA29
Hybrid PFD's; Establishment of Approval Requirements
AGENCY: Coast Guard, DOT.
ACTION: Supplemental notice of proposed rulemaking.
-----------------------------------------------------------------------
SUMMARY: On August 22, 1985 the Coast Guard published an interim final
rule (IFR) in the Federal Register (50 FR 33923) which established
structural and performance standards and procedures for approval of
hybrid inflatable personal flotation devices (PFD). This IFR allowed
the approval of several hybrid PFD's but not enough devices were made
and sold to make a significant difference in the number of lives saved
by this superior performing and more comfortable PFD. The changes
proposed are designed to make hybrid PFD's more affordable and
attractive to recreational boaters. The changes include lowering
manufacturing costs by reducing the amount of repetitive testing
required. Increases in buoyancy are proposed to compensate for removing
of the Type V criteria of being ``REQUIRED TO BE WORN'' to allow
approval of hybrids a Type I, II, and III. Types I, II, and III are
proposed in addition to the existing Type V category. This SNPRM also
proposes approval of hybrids for youths and small children. These
proposals are in hopes that hybrid PFD's will be more widely used and
potentially save more lives.
DATES: Comments must be received on or before April 18, 1994.
ADDRESSES: (a) Comments may be mailed to the Executive Secretary,
Marine Safety Council (G-LRA-2/3406) (CGD 78-174), U.S. Coast Guard,
2100 Second Street, SW., Washington, DC 20593-0001, or may be delivered
to room 3406 at the above address between the hours of 8 a.m. and 4
p.m. Monday through Friday. The telephone number is (202) 267-1477 for
further information about submitting comments. The Executive Secretary
maintains the public docket for this rulemaking. Comments will become
part of this docket and will be available for inspection or copying at
room 3406, U.S. Coast Guard Headquarters.
(b) Copies of the Coast Guard Auxiliary Study, ``Inflatable
Personal Flotation Device Study,'' discussed in this document are
available from the National Technical Information Service, Springfield,
VA 22151 by referring to the publication number. The publication number
for Report No. CG-M-5-81 is AD A107941.
(c) Copies of The Boat/U.S. Foundation for Boating Safety study,
``Inflatable Personal Flotation Device Study: An Examination of
Inflatable PFD Performance and Reliability in Public Use'' dated March
11, 1993, can be obtained at the address mentioned under FOR FURTHER
INFORMATION CONTACT in this section.
(d) UL Standard 1517 may be obtained from Underwriters
Laboratories, Publications Stock, 333 Pfingsten Road, Northbrook, IL
60062.
FOR FURTHER INFORMATION CONTACT:
Mr. Samuel E. Wehr or Lieutenant Junior Grade Roger A. Smith, Office of
Marine Safety, Security, and Environmental Protection, Attn: G-MVI-3/
14, 2100 Second Street SW., Washington, DC 20593-0001, (202) 267-1444.
SUPPLEMENTARY INFORMATION:
Request for Comments
Interested persons are invited to participate in this supplemental
notice of proposed rulemaking (SNPRM) by submitting written views,
data, or arguments. Persons submitting comments should include their
name and address, identify this SNPRM (CGD78-174) and the specific
section or paragraph of this proposal to which each comment applies,
and give reasons for each comment. Persons wanting acknowledgment of
receipt of comments should enclose a stamped self-adddressed postcard
or envelope.
The Coast Guard will consider all written comments received during
the comment period. It may change this proposal in view of the
comments.
Public Hearing
The Coast Guard plans no public hearing. Persons may request a
public hearing by writing to the Marine Safety Council at the address
under ``ADDRESSES.'' If it determines that the opportunity for oral
presentations will aid this rulemaking, the Coast Guard will hold a
public hearing at a time and place announced by a later notice in the
Federal Register.
Drafting Information
The principal persons involved in drafting this document are Mr.
Samuel E. Wehr and Lieutenant Junior Grade Roger A. Smith, Office of
Marine Safety, Security, and Environmental Protection, and LT Ralph L.
Hetzel, Office of Chief Counsel.
Background and Purpose
A notice of proposed rulemaking (NPRM) was published in the Federal
Register on May 29, 1985 (50 FR 21878). Corrections to the NPRM were
published in the Federal Register of June 18, 1985 (50 FR 25274). The
comment period on that proposal ended on July 15, 1985.
The NPRM proposed requirements for both hybrid PFD's and inflatable
lifejackets. An interim final rule promulgating hybrid PFD requirements
was published in the Federal Register on August 22, 1985 (50 FR 33923).
Corrections to this rule were published on February 4, 1986 (51 FR
4349). Comments that addressed concerns relating to the hybrid PFD
requirements were analyzed and discussed in the August 22, 1985
publication.
Proposed Amendments
This notice proposes changes to the requirements for approving
hybrid inflatable PFD's and for the carriage of hybrid PFD's on
commercial vessels. The requirements are self-explanatory and have been
included in a list which cites each specific section number for ease of
presentation.
If adopted, the changes proposed by this SNPRM may be incorporated
by reference in the regulation by citing an updated revision to
Underwriters Laboratories Standard 1517, Hybrid Personal Flotation
Devices.
Discussion of Proposed Revisions
General. Primarily these revisions are based on the U.S. Coast
Guard's experience in evaluating for approval four models of hybrids by
four different manufacturers. Also considered are the discussions and
comments at the 1991 and 1992 meetings of the Industry Advisory Council
(IAC) of Underwriters Laboratories (UL) and the November 11, 1991
National Boating Safety Advisory Council (NBSAC).
This SNPRM proposes approval of hybrid inflatable PFD's for youths
and small children. The rule changes would allow approval of
recreational hybrid inflatable PFD's for weight ranges down to 14 kg
(30 lb) and commercial hybrid inflatable PFDs's for persons weighing
over 23 kg (50 lb). It is the Coast Guard's position that the required
amount of inherent buoyancy and provision for automatic inflation
mechanisms on all hybrids for small children, between 14-23 kg (30-50
lb), justifies approval of hybrids in these weight ranges.
If the requirements in the SNPRM are adopted hybrid PFD's will be
approved in ten recreational and four commercial Type and size
categories. Several tables have been added to improve understanding of
the various categories. Comments are requested on the clarity and
reader comprehensibility of the proposed requirements for the various
Types in this format.
The comments/revisions are divided into seven areas as follows:
Proposed Changes
--Changes to make use of hybrids more attractive.
--Changes to decrease repetitive testing.
--Changes to improve reliability.
--Changes made for clarification.
--Reorganization.
--Changes to 46 CFR subpart 25.25 Life Preservers and Other Lifesaving
Equipment.
--Changes to make editorial corrections.
Changes To Make Use of Hybrids More Attractive
A number of changes are proposed to make hybrid inflatable PFD's
more attractive to recreational boaters and manufacturers. The intent
of the interim final rule was to provide regulations which ensure
introduction of hybrid PFD's with little or no increased risk due to
failure of the inflation system. When placed into practice the rules
proved too burdensome to attract many recreational boaters to buy the
PFD's and for manufacturers to produce them. As a result production and
use of hybrid PFD's is very limited. To date two manufacturers have
actually obtained approval, another is pending approval, and only one
is currently producing. Demand from consumers for hybrid PFD's has been
minimal. A market analysis to determine what advantages or
disadvantages consumers may see in hybird PFD's has not been conducted.
Information which may provide insight into this specific area of
concern is solicited by the Coast Guard and comments from interested
parties are encouraged.
The Coast Guard's efforts to encourage production and use of hybrid
PFD's is based upon comments obtained from the manufacturers of hybrid
PFD's during the 1991 and 1992 Underwriters Laboratories Industry
Advisory Council and 1991 National Boating Safety Advisory Council. In
this light, the Coast Guard proposes to change the following sections
to make hybrids more appealing to boaters and to reduce the regulatory
burden placed upon manufacturers:
Section 160.077-1 Scope
(b) Discussions at the 1991 Underwriters Laboratory Industry
Advisory Conference indicated that consumers are discouraged from
purchasing hybrid PFD's because the REQUIRED TO BE WORN limitation
causes legal questions in the users mind and leaves little flexibility
in use of the devices. Also, in May 1992 NBSAC recommended carriage of
hybrid PFD's be allowed without being ``REQUIRED TO BE WORN.'' To
encourage consumers to purchase--and ultimately wear--hybrid PFD's the
Scope will be revised to indicate that hybrid PFD's approved as Type I,
II, or III devices do not have the restriction of being REQUIRED TO BE
WORN.
(d) Under the interim final rule a hybrid PFD is approved only for
adults. The Coast Guard proposed to amend this paragraph to include
hybrid inflatable PFD's for small children weighing 14-23 kg (30-50
lb), and for youths weighing 23-40 kg (50-90 lb). Current regulations
require hybrid PFD's with Type I and II performance to have automatic
inflation mechanisms. Hybrid PFD's for use by small children weighing
14-23 kg (30-50 lb) would be approved a Type I or II only. Hybrid PFD's
approved for use by youths would be aprpoved as Types I, II, III, and
V. Hybrid PFD's for infants, persons weighing less than 14 kg are not
proposed.
Section 160.077-3 Definitions
(j) The USCG is proposing adoption of standards for approval of
hybrid inflatable PFD's for youths, weighing 23-40 kg (50-90 lb), and
small children, weighing 14-23 kg (30-50 lb). Under the proposal this
paragraph will be revised to redefine ``Reference Vest'' to include
models CKM-1, child medium; and model CKS-2, child small, meeting
subpart 160.047 of this chapter.
Section 160.077-5 Required to be Worn
(c)(1) Recreational hybrid PFD's approved as Type I, II, or III
will meet carriage requirements without being worn. Therefore, this
paragraph will be changed to indicate that only Type V recreational
hybrid PFD's are ``REQUIRED TO BE WORN.''
(c)(2) Commercial hybrid PFD's approved as type I will meet
carriage requirements without being worn. Therefore, this paragraph
will be changed to indicate that only Type V commercial hybrid PFD's
are ``REQUIRED TO BE WORN.''
Section 160.077-7 Type
(a) Type I, II, or III hybrid PFD's will not be bound to Type V
restrictions. In keeping with the change to Sec. 160.077-1(b) and (d)
this paragraph will be revised to indicate that hybrid PFD's may be
approved as Types I, II, III, or V for persons in various weight ranges
over 23 kg (50 lb.) and as Types I and II for persons weighing 14-23 kg
(30-50 lb). Type V is not a performance Type. Type V approval means the
device is limited to special uses or conditions. Type V hybrid PFD's
are ``REQUIRED TO BE WORN`` because they have reduced inherent
buoyancy. Type V hybrid PFD's will be required to have Type I, II, or
III performance when inflated.
(b) The proposed change to hybrid PFD Types approved, discussed in
Sec. 160.077-7(a) of this section, authorizes hybrid PFD's to be
approved as Type I, II, III, or V for persons weighing over 23 kg (50
lb) and Types I and II for persons weighing 14-23 kg (30-50 lb). To be
consistent with that change, this paragraph will be revised to indicate
that hybrid PFD's must have at least Type I, II, or III performance.
Section 160.077-13 Materials--Commercial Hybrid PFD
(d) Current commercial equipment regulations only require vessels
in certain operations to carry PFD's with approved PFD lights. Because
PFD lights are not required for all commercial vessels the requirement
that commercial hybrid PFD's be provided with a light will be deleted.
Section 160.077-15 Construction and Performance--Recreational Hybrid
PFD
(b)(13) A proposed requirement will be added to provide Type I
recreational hybrid PFD's with a PFD light attachment. This requirement
is intended to provide vessel operators with an option to attach a PFD
light, while avoiding damage to the inflation chamber due to improper
light attachment.
Section 160.077-17 Additional Requirements
(b)(4) There have been no field complaints concerning failure of
the inflation chamber on hybrid inflatable PFD's. Studies conducted by
the USCG Auxiliary (INFLATABLE PERSONAL FLOTATION DEVICE STUDY, Report
No. CG-M-5-81) and The Boat/U.S. Foundation for Boating Safety
(``INFLATABLE PERSONAL FLOTATION DEVICE STUDY: An Examination of
Inflatable PFD Performance and Reliability in Public Use'' dated March
11, 1993) have provided additional information on fully inflatable
PFD's which leads the USCG to conclude that one inflation chamber can
provide reliability equivalent to dual chambers in hybrid PFD's.
Therefore, the required number of inflation chambers on commercial
hybrid PFD's has been reduced from two to one. However, if the device
is marked as a ``lifejacket'' meeting the Safety of Life at Sea (SOLAS)
requirements, two inflation chambers must still be provided.
(b)(8) Adults have a wide range of chest sizes. To provide all
passengers with a suitable size PFD, the Coast Guard proposes to add a
requirement that adult commercial hybrid PFD's to be universally sized.
(b)(9) Operators of commercial vessels may be required to have
PFD's with approved PFD lights attached. The USCG proposes to drop the
requirement for commercial hybrid PFD's to be provided with an approved
PFD light at time of manufacture as discussed in Sec. 160.077-13(d).
Instead, a requirement will be added to provide all commercial hybrid
PFD's with a PFD light attachment at time of manufacture. This change
is intended to provide vessel operators with an option to attach a PFD
light, relieve manufacturers of this requirement, and avoid potential
damage to the inflation chamber due to improper light attachment in the
field.
Section 160.077-23 Over-pressure
(h)(4) The inflation chambers on hybrid PFD's sometimes fail to
hold the required pressure during the over-pressure test although they
remain serviceable. The loss of pressure is often attributed to the
stretching of the inflation chamber material, thus increasing the
volume of the chamber and reducing the static pressure reading. This
paragraph revision is proposed to allow prestressing of the inflation
chamber.
Section 160.077-23 Air Retention
(h)(5) For the same reasons discussed in the paragraph covering
Sec. 160.077-23(h)(4) above, the Coast Guard proposes revision of this
paragraph to allow prestressing of the inflation chamber prior to the
Air Retention test.
Section 160.077-23 Disposition of PFD's Rejected in Testing or
Inspections
(k)(1) The paragraph will be changed to indicate that an authorized
representative of the Commandant may also allow reworking of the lot to
correct the defect in a rejected PFD lot. In addition, this paragraph
will be revised to delete the text ``(G-MVI-3)'' in response to the
change in definition of ``Commandant,'' discussed in Sec. 160.077-3(a)
under ``Changes to make editorial corrections.''
(k)(2) The paragraph will be changed to indicate that an authorized
representative of the Commandant may allow reexamination or
reinspection of any PFD rejected in a final lot examination or
inspection. In addition, this paragraph is to be revised to delete the
text ``(G-MVI-3)'' in response to the change in definition of
``Commandant,'' discussed in Sec. 160.077-3(a) under ``Changes to make
editorial corrections.''
Section 160.077-27 Pamphlet
(a) through (f) In keeping with Sec. 160.077-7(a), Type I, II, and
III hybrid PFDs will not have the approval limitations of a Type V
hybrid PFD. In consideration of this change, a requirement will be
added for a different pamphlet for each hybrid PFD Type. The proposed
method of change is to adopt revisions to Underwriters Laboratories
``Standard for Safety'', UL 1517, section 39, ``Information Pamphlet,''
if the necessary revisions can be made in a timely manner. In this
SNPRM, the text of the proposed changes is published in its entirety
where the current text of UL 1517 is not applicable to Type I, II and
III hybrids. Text in this SNPRM would be used in the final rule if UL
1517 is not revised at that time.
Section 160.077-29 Manual Contents
(b) through (e) It is anticipated that the designs for Type I, II,
III, or V Recreational hybrid PFDs will be different. Therefore,
paragraph (b) will be revised and several new paragraphs added to
require that each Type I, II, III, or V Recreational Hybrid PFD be
provided with an owner's manual appropriate to that type PFD. The
proposed method of change is to adopt revisions to Underwriters
Laboratories ``Standards for Safety'', UL 1517, section 40, ``Owners
Manual,'' if the necessary revisions can be made in a timely manner. In
this SNPRM, the test of the proposed changes is published in its
entirety where the current text of UL 1517 is not applicable to Type I,
II, and III hybrids. Text of this SNPRM would be used in the final rule
if UL 1517 is not revised at that time. Former paragraph (c) is
redesignated (f), which is discussed later in this preamble. The new
paragraph (c) addresses the manual for Type I, II, or III recreational
hybrids PFDs which do not have to be worn to meet carriage
requirements. The requirements for Type V recreational hybrid PFD
owner's manual remains the same but is moved to paragraph (d). The
requirements of former paragraph (b)(2) are now in paragraph (e).
Section 160.077-29 Commercial Hybrid PFD
(c)(2) This paragraph will be changed to indicate that commercial
hybrid PFDs approved as a ``Work Vest Only'' or Type I PFD must contain
the information required by the Approval Certificate or in paragraph
(b)(1) of this section.
Section 160.077-30 Spare Operating Components
(a) The changes to the Scope, Sec. 160.077-1(b) allow hybrid PFDs
to be approved as Type I, II, III, or V. In response to the changes in
the Scope this paragraph will be amended to require all Types of hybrid
PFDs to be provided with spare operating components at the time of
sale.
(a)(1) There has been some confusion concerning the number of
inflation medium cartridges which should be provided with the hybrid
PFD at the time of sale. This paragraph has been changed to indicate
that when hybrid PFD's with a manual or automatic inflation mechanism
are provided with one inflation medium cartridge loaded into the
inflation mechanism only two spare cartridges need to be included. When
hybrid PFD's are sold without an inflation medium cartridge loaded into
the inflation mechanism they must be provided with at least three
cartridges.
This paragraph will also be renumbered to be consistent with
standard Code of Federal Regulations (CFR) format.
(a)(2) Another area of misunderstanding has been the number of
water sensitive elements to be provided at the time of sale. To clarify
the required number of water sensitive elements to be provided the
paragraph has been changed. When hybrid PFD's with an automatic
inflation mechanism are provided with one water sensitive element
loaded into the inflation mechanism only two spare water sensitive
elements need to be provided. When hybrid PFD's are sold without a
water sensitive element loaded into the inflation mechanism they must
be provided with at least three water sensitive elements.
This paragraph will also be renumbered to be consistent with
standard CFR format.
Section 160.077-31 Recreational Hybrid PFD
(c) The required marking text for recreational hybrid PFD's will be
changed to be consistent with revisions to Type, discussed under
Sec. 160.077-7(a) of this section and buoyancy changes, covered under
``Changes to improve reliability'', Sec. 160.077-19(b)(6).
Section 160.077-31 Commercial Hybrid PFD
(d) The required marking text for commercial hybrid PFD's will be
changed to be consistent with revisions to Type, discussed under
``Changes to make use of hybrids more attractive'', Sec. 160.077-7(a)
and buoyancy changes, covered under ``Changes to improve reliability'',
Sec. 160.077-21(c)(3).
Section 160.077-31 All PFD's
(e)(5) The requirement for marking generic identification of the
inherently buoyant material is of little value to the hybrid PFD user.
Therefore, the marking requirement for generic identification of the
inherently buoyant material will be deleted.
Section 160.077-31 Foam
(g)(1) The space allotted to this paragraph is greater than the
importance of the information provided. The text will be revised to
better balance the information provided on the label by shortening the
marking requirement for flotation material buoyancy. The statement ``As
explained in the owner's manual, test at least once annually for
buoyancy loss.'' is proposed to follow the minimum buoyant force
statement in paragraph (c) or (d) of this section.
Section 160.077-31 Type Equivalence
(h) Because hybrid PFD's marked as Type I, II, or III will be
tested as such, the Type Equivalence marking requirement will be
changed to be applicable to Type V hybrids only.
Section 160.077-31 Approved Use
(j)(1) This paragraph will be amended to show that Type I
commercial hybrid PFD's meet carriage requirements without restriction.
Type V commercial hybrid PFD's remain ``Required to Be Worn.''
(j)(4) This paragraph will be added to allow manufacturers the
option of leaving the approved use unspecified on the label if
authorized to do so by the Commandant, U.S. Coast Guard.
Section 160.077-31 Size Ranges
(1) This paragraph will be added to specify the exact text to be
used when providing PFD size information on labels for approved hybrid
PFD's.
Section 160.077-33 Approval Procedures
(a)(3)(vi) The proposed changes to the Scope and Types discussed in
Secs. 160.077-1(d) and 160.077-7(a) of this section, authorize hybrid
PFD's to be approved in various Types and size ranges. To be consistent
with these changes, this paragraph will be added to require
manufacturers to provide the size range of the intended wearers when
applying for USCG approval of a hybrid PFD.
Changes To Decrease Repetitive Testing
Some of the required tests are repetitive and increase the cost of
producing hybrid PFD's. Elimination of repetitious testing should
reduce manufacturing costs which may in turn encourage increased
production. With the intent to encourage greater production through
lower production costs the following changes are proposed.
Section 160.077-23 Manufacturer
(b)(1)(i) Situations have occurred where extremely small lots (less
than 50) of hybrid PFD's have been manufactured. Requirements for
testing each lot by both the manufacturer and laboratory inspector
increase the individual cost of hybrid PFD's produced in such small
numbers. Reduction of repetitive testing is proposed by revising this
paragraph to combine the manufacturer's and laboratory inspector's
tests when five consecutive lots do not exceed a total of 250 devices.
This revision would reduce repetitive testing and decrease production
costs without compromising the safety of approved devices.
Section 160.077-23 Independent Laboratory
(b)(2)(ii) Historically the number of hybrid PFD's produced has
been nominal. In some calendar quarters very small lots have been
produced. The requirement for an independent laboratory inspection
every quarter increases production costs when small lots are produced.
Reduction of independent laboratory inspections is proposed by changing
this paragraph to require one inspection annually when not more than
five lots, with no more than 1000 devices per lot, are produced per
calendar year.
(b)(2)(iv) This paragraph will be revised to show reference to
paragraph (b)(2)(v) which provides an exception to the number of
required records examinations, and test performance observations when
not more than five lots are produced during any calendar year.
(b)(2)(v) For the same reasons stated in the proposed changes to
paragraph (b)(2)(ii) of this section, this paragraph will be added to
clarify that the number of required records examinations and test
performance observations will be changed to one annually when not more
than five lots are produced per calendar year.
Section 160.077-23 Samples
(d)(4) As per the reasons stated in proposed changes to paragraph
(b)(2)(ii) of this section, this paragraph will be revised to indicate
that when the total production for any five consecutive lots does not
exceed 250, the manufacturer's and inspector's testing and inspection,
can be combined.
(d)(5) Lots containing small numbers of hybrid PFD's are often
produced. Requirements for individual tests and inspections by both the
manufacturer and the independent laboratory increase production costs
when small lots are produced. Reduction of repetitive test and
inspections is proposed by authorizing the manufacturer's and
inspector's tests to be run on the same sample at the same time when
the total production for any five consecutive lots does not exceed
250.TABLE 160.077-23B, Inspector's Sampling.
Footnote 2. Field use of hybrid PFD's had proven the devices to be
reliable and there have been no complaints concerning failures. To
lower production costs the frequency of this test will be reduced from
quarterly to annually.
Footnote 3. There have been no reports of the required marking
becoming illegible on hybrid PFD's. To reduce production costs the
frequency of this test will be reduced from quarterly to two annually.
Section 160.077-23 Calibration
(g)(2) Manufacturers have not exposed problems during equipment
calibrations. Because equipment calibration had proven reliable the
Coast Guard proposes reducing the test equipment calibration interval
to once annually.
Changes To Improve Reliability
Section 160.077-15 Construction and Performance--Recreational Hybrid
PFD
(b)(14) This paragraph will be added to reaction to the changes to
the Scope in Sec. 160.077-1(b) and Type discussed in Sec. 160.077-7,
under Changes to make use of hybrids more attractive.'' To compensate
for removing the REQUIRED TO BE WORN statement the Coast Guard is
proposing to add additional inherent buoyancy for recreational Type I,
II, and III hybrid PFD's. Deliberations from the 1991 and 1992
Underwriters Laboratories Industry Advisory Council meeting and the
1991 National Boating Safety Advisory Council concerning the amount of
additional buoyancy to add to adult hybrid PFD's were considered. The
options considered and discussed at those meetings included increasing
the additional buoyancy to 40 N (9 lb) or 45 N (10 lb) in Type V hybrid
for adults, weighing over 40 kg (90 lb). The design variations of
either are not significant in affecting wear and comfort. The Coast
Guard proposes the 45 N (10 lb) option in order to provide a minimum
buoyancy closer to the International Standards Organization (ISO)
proposed minimum standard of
50 N.
In this paragraph the Coast Guard is also proposing buoyancy
specifications for recreational hybrid PFD's for persons weighing 14-23
kg (30-50 lb) and 23-40 kg (50-90 lb). The USCG is not proposing to
approve recreational hybrid inflatable PFD's for infants, weighing less
than 14 kg (30 lb).
In addition, the Coast Guard is proposing to increase the total
required buoyancy when inflated for Type I recreational hybrids for
adults. The total buoyancy will be increased to 130 N (30 lb), in lieu
of the 100 N (22 lb) inflated buoyancy requirement for adult Type II,
III, or V hybrids. This proposal is based on the Coast Guard's
determination that this buoyancy is the minimum amount necessary to
provide performance as required by SOLAS 74/83. Depending on the PFD's
design buoyancy distribution, more buoyancy may be required. Although
recreational devices are not required to meet the requirements of SOLAS
74/83, the greater performance is consistent with the Type I
classification and can be obtained at nominal cost.
Section 160.077-17 Construction and Performance--Commercial Hybrid PFD
(b)(10) In lieu of the Type V requirement, the Coast Guard proposes
to increase the minimum inherent and minimum total buoyancies for adult
Type I commercial hybrids. This proposed paragraph revision requires
the minimum inherent buoyancy for adult Type I commercial hybrids to be
70 N (15.5 lb), increased from 45 N (10 lb). The Coast Guard proposes
to increase the amount of total buoyancy for commercial Type I hybrids
to 130 N (30 lb) in lieu of the 100 N (22 lb) total buoyancy
requirement for Type V hybrids.
In addition the Coast Guard proposes to increase the required
inherent buoyancy in adult type V commercial hybrid inflatable PFD's.
To compensate for the loss of an extra inflation chamber, as discussed
under ``Changes to make use of hybrids more attractive'' Sec. 160.077-
17(b)(4), the minimum inherent buoyancy requirement for adult type V
commercial hybrid inflatable PFD's will be increased from 45 N (10 lb)
to 60 N (13 lb).
Section 160.077-19 Buoyancy, Buoyancy Distribution, and Inflation
Medium Retention Test
(b)(6) As discussed under the Scope in Sec. 160.077-1(b), in
``Changes to make hybrids more attractive'' it is proposed that the
``Required To Be Worn'' statement be removed from Type I, II, or III
hybrid PFD's. To compensate for removing the REQUIRED TO BE WORN
condition, additional inherent buoyancy is proposed to be added as
discussed in Sec. 160.077-15(b)(14) which will be required to be tested
for by this paragraph.
Section 160.077-21 Buoyancy and Inflation Medium Retention Test
(c)(3) In Sec. 160.077-17 above, the Coast Guard is proposing
minimum buoyancies for hybrid PFD's. This paragraph will be revised to
require commercial hybrid's to be tested for and meet the minimum
buoyancies specified in Sec. 160.077-17(b)(10).
Section 160.077-21 Flotation Stability Criteria
(d)(3) (i) and (ii) These paragraphs are added to ensure commercial
hybrid PFD's provide adequate freeboard commensurate with other
commercial PFD's. Commercial Type I hybrids must provide at least 100
mm (4 inches) of freeboard and SOLAS lifejackets must provide at least
120 mm (4.75 inches) of freeboard.
Changes Made for Clarification
Section 160.077-1 Scope
(c) This paragraph will be revised to clarify that hybrid PFD's
approved as Type I SOLAS 74/83 Life Jackets meet the requirements for
carriage on all inspected commercial vessels.
Section 160.077-3 Definitions
(l) This section will be redesignated Sec. 160.077-2 and a
definition will be added to clarify that a PFD marked as a SOLAS
lifejacket meets the requirements for lifejackets in the 1983
Amendments to the International Convention for the Safety of Life at
Sea, 1974 (SOLAS 74/83).
Section 160.077-7 Type
(c) This section will be redesignated Sec. 160.077-4 and this
paragraph will be added to indicate that hybrid PFDs may be approved
for use on recreational boats, commercial vessels or both if the
applicable requirements are met.
Section 160.077-15 Performance
(a)(2)(ii) PFD's approved as Type I or II must not require second
stage donning to achieve that performance. The interim final rule
addresses only Type II performance. This paragraph will be revised to
make it clear that PFD's marked Type I or II, or as Type V providing
Type I or II performance must not require second stage donning to
achieve that performance.
Section 160.077-15 Construction; General
(b)(3) This paragraph will be amended to reflect that devices
approved as Type I, as well as Type II, are to be provided with at
least one automatic inflation mechanism that inflates at least one
chamber.
Section 160.077-15 Inflation Mechanism
(c)(2)(ii) This paragraph will be changed to clarify that dust
caps, if provided, cannot be locked.
Section 160.077-15 Deflation Mechanism
(d)(3) This paragraph will be changed by replacing the word ``can''
with ``may'' to clarify that the oral inflation mechanism is an option
in meeting the deflation mechanism requirement.
Section 160.077-19 Inflated Flotation Stability
(b)(3)(iii) The Coast Guard proposes to approve hybrid PFD's as
Types I, II, III, and V for adult and youth sizes, and Type I and Type
II for small child sizes for use on recreational boats, commercial
vessels, or both if they perform accordingly and the applicable
requirements are met. A requirement to test for Type I performance in
accordance with the requirements specified under Sec. 160.176-13(d)(2)
will be added if the device is to be so labeled.
In response to the suggested approval Types and sizes, the
requirements for inflated flotation stability need revision. The
proposed method of change is to adopt revisions to Underwriters
Laboratories ``Standard for Safety'', UL 1517, section 15 ``Inflated
Flotation Stability Test.''
In addition, this paragraph will be revised by specifying that the
reference vest used must be the appropriate size device.
Section 160.077-21 Righting Action
(c)(4)(ii) As presently written in UL 1517, section S8, one
inflation chamber must be deflated during the Righting Action Test. The
Coast Guard proposes to change to one chamber the current requirement
for two chambers on commercial hybrid PFD's to reduce costs. This
paragraph will be changed to clarify that one inflation chamber has to
be deflated only if there is more than one chamber.
Section 160.077-23 Facilities and Equipment
(g)(3)(x) This section requires manufacturers to provide the
required test equipment for performance of production tests. However,
the equipment necessary to perform the required Inflation Chamber
Materials production tests was not included in the interim final rule.
This paragraph will be added to require manufacturers to provide the
Inflation Chamber Materials production test equipment.
Section 160.077-29 Manual
(f)(5) As discussed in Secs. 160.077-13(d) and 160.077-17(b)(9)
under ``Changes to make use of hybrids more attractive'', the USCG
proposes to drop the requirement for commercial hybrid PFDs to be
provided with an approved PFD light at the time of manufacture. Former
paragraph (c) of this section is redesignated (f) and this paragraph
will be added to include a requirement that the manual must specify the
recommended type of PFD light to be used if a light is not provided by
the manufacturer. Paragraph references in this section are revised to
agree with the other revisions to this section discussed earlier in
this preamble.
Section 160.077-30 Temporary Marking
(b)(1) The original paragraph (b) will be renumbered (b)(1) in
conjunction with the addition of paragraph (b)(2) to this section. This
paragraph defines the temporary marking requirements when a hybrid PFD
is sold in a ready-to-use condition. Paragraph (b)(2) is proposed to
define the temporary marking requirements when a hybrid PFD is not sold
in a ready-to-use condition.
(b)(2) Section 160.077-30(a)(1) (i) and (ii) will be amended to
clarify that a total of three inflation medium cartridges and three
water sensitive elements must be provided with the hybrid device when
sold. Additionally, a cartridge and element may or may not be pre-
loaded at the time of sale. This paragraph will be added to refer to
the marking requirement specified in Sec. 160.077-15(c)(3)(ii) which
will be used when the device is sold without either an inflation medium
cartridge, or a water sensitive element or both pre-loaded into the
inflation mechanism.
Section 160.077-33 Approval Procedures
(a)(3)(vi) This section will be redesignated Sec. 160.077-6 and
this paragraph is proposed to indicate that the intended size range of
wearers must be included with the application package.
Reorganization
A number of the sections within the subpart have been moved to be
consistent with the organization of the inflatable lifejacket
regulation at 46 CFR 160.176. The new organization with the old section
numbers where applicable, and the section titles, is as follows:
------------------------------------------------------------------------
New section
Old section Section title
------------------------------------------------------------------------
160.077-1.. same Scope.
160.077-2.. 160.077-3 Definitions.
160.077-3.. 160.077-5 Required to be worn.
160.077-4.. 160.077-7 Type.
160.077-5.. 160.077-9 Incorporation by Reference.
160.077-6.. 160.077-33 Approval Procedures.
160.077-7.. 160.077-35 Procedure for Approval of Design or Material
Revision.
160.077-9.. 160.077-37 Independent Laboratories.
------------------------------------------------------------------------
Remaining sections are unchanged.
Changes to 46 CFR Subpart 25.25 Life Preservers and Other Lifesaving
Equipment.
Section 25.25-5 Life Preservers and Other Lifesaving Equipment
Required
(f)(1) The text previously published as Sec. 25.25-5(f)(2) has been
moved to this paragraph to make it clear only Type V commercial hybrid
PFD's will be required to be worn as stated in the revised Sec. 25.25-
5(f)(3).
(f)(2) The text previously published as Sec. 25.25-5(f)(3) has been
moved to this paragraph to make it clear only Type V commercial hybrid
PFD's will be required to be worn as stated in the revised Sec. 25.25-
5(f)(3).
(f)(3) The Coast Guard proposes to revise the Scope in 46 CFR
subpart 160.077-1(b) to indicate that hybrid PFD's approved as Type I
devices do not have the restriction REQUIRED TO BE WORN. In keeping
with the changes to the scope in 46 CFR subpart 160.077-1(b), the text
(originally published as Sec. 25.25-5(f)(1)) will be moved to paragraph
(f)(3) and will be changed to show that Type I commercial hybrid PFD's
do not have to be worn to meet carriage requirements. Type V commercial
hybrid PFD's remain ``Required To Be Worn.''
Changes To Make Editorial Corrections
Section 160.077-3 Definition.
(a) This paragraph is revised to keep the definition of
``Commandant'' consistent with the definition found in Subpart 160.176-
3.
(h) This paragraph is revised to drop the reference to
Sec. 175.3(b) as a result of the proposed rule changes to 33 CFR part
175 published in the Federal Register on November 9, 1992 (57 FR
53410).
Section 160.077-11 Flotation Material
(b)(1)(iii) The Omnibus Trade and Competitiveness Act of 1988
amended the Metric Conversion Act of 1975 to declare that each federal
agency shall change over to the metric system. This paragraph is
revised in accordance with the Omnibus Trade and Competitiveness Act of
1988 to include metric as well as English measurements.
Section 160.077-11 Flotation Material
(j) This paragraph is revised to change the subparagraph
designation from an upper case (J) to a lower case (j).
Section 160.077-15 Construction and Performance--Recreational Hybrid
PFD's
(b)(15) Section 160.077-15(b)(13) is renumbered Sec. 160.077-
15(b)(15) to incorporate the additional requirements proposed as
Sec. 160.077-15(b) (13) and (14) in this SNPRM.
Section 160.077-19 Approval Testing--Recreational Hybrid PFD
(e) This paragraph is revised to delete the text ``(G-MVI-3)'' in
response to the change in definition of ``Commandant,'' discussed in
Sec. 160.077-3(a) above.
Section 160.077-21 Approval Testing--Commercial Hybrid PFD
(g) This paragraph is revised to delete the text ``(G-MVI-3)'' in
response to the change in definition of ``Commandant,'' discussed in
Sec. 160.077-3(a) above.
Section 160.077-23 General
(a)(2) This paragraph is revised to delete the text ``(G-MVI-3)''
in response to the change in definition of ``Commandant,'' discussed in
Sec. 160.077-3(a) above.
Section 160.077-23 Equipment
(g)(3)(iii) This paragraph is revised to show that 14 g equals 0.5
oz.
Section 160.077-23 Independent Laboratory Inspection
(j)(4)(iii) This paragraph is revised to delete the text ``(G-MVI-
3)'' in response to the change in definition of ``Commandant,''
discussed in Sec. 160.077-3(a) above.
Section 160.077-31 Statement of Minimum Uniflated Bouyancy
(k) This paragraph is revised in accordance with the Omnibus Trade
and Competitiveness Act of 1988 to include metric as well as English
measurements.
Section 160.077-33 Approval Procedures
(b) and (c)(1) These paragraphs are revised to delete the text
``(G-MVI-3)'' in response to the change in definition of
``Commandant,'' discussed in Sec. 160.077-3(a) above.
Section 160.077-35 Procedure for Approval of Design or Material
Revision
(a) and (b) These paragraphs are revised to delete the text ``(G-
MVI-3)'' in response to the change in definition of ``Commandant,''
discussed in Sec. 160.077-3(a) above.
Section 160.077-37 Independence Laboratories
This paragraph is revised to delete the text ``(G-MVI-3)'' in
response to the change in definition of ``Commandant,'' discussed in
Sec. 160.077-3(a) above.
46 CFR 25.25-5 Life Preservers and Other Lifesaving Equipment Required
(f) This paragraph is amended to correct a typographical error by
changing PED to PFD.
Regulatory Evaluation
This proposal is not a significant regulatory action under
Executive Order 12866 and is nonsignificant under Department of
Transportation Regulatory Policies and Procedures (44 FR 11040,
February 26, 1979). A Regulatory Evaluation was originally placed in
the rulemaking docket in 1985, reviewed in May 1991 with regard to
inflatable lifejackets, and reconsidered in April 1993, concerning
hybrid PFD's in association with this SNPRM. The Regulatory Evaluation,
in spite of its age, was found still viable. The information obtained
from the original study of inflatable lifejackets has not changed
significantly in light of a comparable two and a half year
investigation conducted by the Boat/U.S. Foundation for Boating Safety
completed in March 1993. The annual number of casualties and drownings
involving recreational boating accidents has not changed significantly
since these figures were gathered. Further, the Coast Guard is
proposing to improve the limited performance of devices already
approved under the current regulations by requiring new Type I, II, or
III hybrid devices to have increased inherent buoyancy. This Regulatory
Evaluation is available in the docket for inspection or copying at the
location indicated under addresses.
The evaluation provides an explanation of the estimated costs of
these proposed regulations. There will no increase in costs to any
sector under these proposed changes since hybrid PFD's are only being
approved as an option to existing approved devices. The total approval
costs per design are expected to be approximately $12,000 for hybrid
inflatable PFD's. Costs to approve other types of PFD's are
approximately $6,000. The additional cost to approve hybrid PFD's could
easily be absorbed in the cost of the units produced. The cost increase
per device would be small considering the number of devices produced
under authorization of each approval certificate. The Coast Guard
anticipates that, within the first year after issuing the final rules,
one or two designs will be approved.
Production inspection costs imposed by these regulations will be
approximately $1,000 for the largest size lot of inflatable lifejackets
permitted. This cost is similar to that incurred for other types of
approved PFD's.
The retail cost, per device, is expected to be $80-$200 for hybrid
PFD's. Currently approved PFD's range in price from $7-$200. Type I
devices that could be replaced by hybrid PFD's have an average cost of
about $40.
These regulations provide an alternative to users for whom limited
stowage space or other operational considerations make the carriage of
conventional inherently buoyant PFD's impractical or inadvisable. For
these users, the optional carriage of hybrid PFD's will meet their
specific operational needs and will therefore justify the higher cost
relative to inherently buoyant PFD's.
These regulations will have little or no effect on federal, state,
or local governments except in their capacities as consumers of PFD's.
Coast Guard steps to implement these proposed changes will be done
within the scope of ongoing marine safety activities, and there will be
no need for additional federal budget commitments.
Small Entities
Under the Regulatory Flexibility Act (5 U.S.C. 601 et seq.), the
Coast Guard must consider whether this proposal will have a significant
economic impact on a substantial number of small entities. ``Small
entities'' include independently owned and operated small businesses
that are not dominant in their field and that otherwise qualify as
``small business concerns'' under section 3 of the Small Business Act
(15 U.S.C. 632).
Based upon the information in the evaluation this proposal, if
adopted, would not have a significant economic impact on a substantial
number of small entities. If you feel that your business qualifies as a
small entity and would suffer significant, negative economic impact,
please submit a comment explaining why your business qualifies as a
small entity and to what degree the proposed regulations would
economically affect your business. Cost data submitted will be
thoroughly evaluated before publication of the final rule.
Collection of Information
Under the Paperwork Reduction Act (44 U.S.C. 3501 et seq.), the
Office of Management and Budget (OMB) reviews each proposed rule which
contains a collection of information requirement to determine whether
the practical value of the information is worth the burden imposed by
its collection. Collection of information requirements include
reporting, recordkeeping, notification, and other similar requirements.
This proposal requires separate PFD manuals for each hybrid PFD
Type which may increase paperwork burdens. However, the Coast Guard has
determined that this additional load will be balanced be decreasing the
frequency of currently approved collection of information requirements.
The current requirements will be reduced by decreasing the number of
required inspections and tests.
Federalism
The Coast Guard has analyzed this proposal in accordance with the
principles and criteria contained in Executive Order 12612 and has
determined that this proposal does not have sufficient federalism
implications to warrant the preparation of a Federalism Assessment.
This supplemental notice of proposed rulemaking revises established
safety standards for hybrid inflatable personal flotation devices
(PFD). The authority to regulate concerning PFD's is committed to the
Coast Guard by statute. Furthermore, since PFD's are manufactured and
used in the national marketplace, safety standards for PFD's should be
of national scope to avoid unreasonably burdensome variances.
Therefore, if this rule becomes final, the Coast Guard intends it to
preempt State action addressing the same subject matter.
Environment
The Coast Guard considered the environmental impact of this
proposal and concluded that under section 2.B.2. of Commandant
Instruction M16475.1B, this proposal is categorically excluded from
further environmental documentation. These proposed rules are expected
to have no significant effect on the environment. A Categorical
Exclusion Determination statement has been prepared and has been placed
in the rulemaking docket.
List of Subjects
46 CFR Part 25
Fire prevention, Marine safety, Reporting, and Recordkeeping
requirements.
46 CFR Part 160
Marine safety, Reporting and recordkeeping requirements.
In consideration of the foregoing, the Coast Guard proposes to
amend parts 25 and 160 of title 46 of the Code of Federal Regulations
as follows:
PART 25--REQUIREMENTS
1. The authority citation for part 25 is revised to read as
follows:
Authority: 33 U.S.C. 1903(b), 46 U.S.C. 3306, and 4302; 49 CFR
1.46.
Subpart 25.25--Life Preservers and Other Lifesaving Equipment
2. In Sec. 25.25-5, paragraph (f) is revised to read as follows:
Sec. 25.25-5 Life preservers and other lifesaving equipment required.
* * * * *
(f) On each vessel, regardless of length and regardless of whether
carrying passengers for hire, an approved commercial hybrid PFD may be
substituted for a life preserver, buoyant vest, or marine buoyant
device required under paragraphs (b) or (c) of this section. Each
hybrid PFD is accepted as meeting the requirements in paragraphs (b) or
(c) of this section only if it is--
(1) Used in accordance with the conditions marketed on the PFD and
in the owner's manual; and
(2) Labeled for use on commercial vessels; and
(3) In the case of a Type V commercial hybrid PFD, worn when the
vessel is underway and the intended wearer is not within an enclosed
space.
PART 160--LIFESAVING EQUIPMENT
3. The authority citation for part 160 is revised to read as
follows:
Authority: 46 U.S.C. 3306, 3703, and 4302; E.O. 12234, 45 FR
58801, 3 CFR, 1980 Comp., p. 277; 49 CFR 1.46.
Subpart 160.077--Hybrid Inflatable Personal Flotation Devices
4. in Sec. 160.077-1, paragraphs (b), (c), introductory text, and
(d) are revised to read as follows:
Sec. 160.077-1 Scope.
* * * * *
(b) Other regulations in this chapter and in 33 CFR part 175 allow
certain commercial vessels and recreational boats to carry Type I, II,
or III hybrid PFD's to meet the carriage requirements. Type V hybrid
PFD's may be substituted for other required PFD's if they are worn
under conditions prescribed in their manual as required by
Sec. 160.077-29 and on their marking as prescribed in Sec. 160.077-31.
For recreational boats or boaters involved in a special activity,
hybrid PFD approval may also be limited to that activity.
(c) Unless approved as a Type I SOLAS Life Jacket, a hybrid PFD on
an inspected commercial vessel will be approved only--
* * * * *
(d) A hybrid PFD will be approved for adults, weighing over 40 kg
(90 lb); youths, weighing 23-40 kg (50-90 lb); small children, weighing
14-23 kg (30-50 lb); or for the size range of persons for which the
design has been tested, as indicated on the PFD's label.
* * * * *
5. Section 160.077-3 is redesignated Sec. 160.077-2, and in newly
redesignated Sec. 160.077-2, paragraphs (a), (h) and (j) are revised,
and paragraph (l) is added to read as follows.
Sec. 160.077-2 Definitions
* * * * *
(a) Commandant means the Chief of the Survival Systems Branch, U.S.
Coast Guard, Office of Merchant Marine Safety. Address: Commandant (G-
MVI-3/14), U.S. Coast Guard Headquarters, 2100 Second Street SW,
Washington, DC 20593-0001.
* * * * *
(h) Recreational hybrid PFD means a hybrid PFD approved for use on
a recreational boat as defined in 33 CFR 175.3.
* * * * *
(j) Reference vest means a model AK-1, adult PFD, model CKM-1,
child medium PFD; or model CKS-2, child small PFD, meeting requirements
of subpart 160.047 of this chapter, except that, in lieu of the weight
and displacement values prescribed in Tables 160.047-4(c)(2) and
Sec. 160.047-4(c)(4), each front insert must have the minimum weight of
kapok as shown in Table 160.077-2(j). To achieve the specified volume
displacement, front insert pad covering may be larger than the
dimensions prescribed by Sec. 160.047-1(b) and the width of the
envelope may be increased to a circumference \1/4\'' larger than the
filled insert pad circumference.
Table 160.077-2(j).--Reference Vest Minimum Kapok Weight and Volume Displacement
[Devices for adults, weighing over 40 kg (90 lb)]
----------------------------------------------------------------------------------------------------------------
Front insert (2 each) Back insert
---------------------------------------------------------------
Reference PFD type Volume Volume
Minimum kapok displacement Minimum kapok displacement
weight g (oz) values N (lb) weight g (oz) values N (lb)
----------------------------------------------------------------------------------------------------------------
Type I * & V.................................... 319 54
1 213 36
1
Commercial.................................. (11.25) 12.2
1 156 27
1
V Recreational.............................. (8.25) (9.0
1 128 22
1
(6.75) (7.250.25)
Type II, III,................................... 156 27
1 113 18
1
and V*...................................... (5.5) (6.0
1 113 18
1
(5.5) (6
0.25) (4.0) (4.0
1 85 14.5<plus-minu
s1
(4.5) (4.75<plus-min
u0.25) (3.0) (3.25<plus-min
u0.25)
----------------------------------------------------------------------------------------------------------------
*Both Recreational and Commercial.
* * * * *
(l) SOLAS lifejacket, in the case of a hybrid inflatable PFD, means
a PFD approved as meeting the requirements for lifejackets in the 1983
Amendments to the International Convention for the Safety of Life at
Sea, 1974 (SOLAS 74/83).
6. Section 160.077-5 is redesignated Sec. 160.077-3 and in newly
redesignated Sec. 160.077-3 paragraphs (c) (1) and (2) are revised to
read as follows:
Sec. 160.077-3 Required to be worn.
(a) As provided in Subpart 25.25 of this chapter, and in 33 CFR
part 175, a Type V hybrid PFD may be used to meet the Coast Guard PFD
carriage requirements in those regulations only if it is used in
accordance with any requirements on the approval label. Those marked
``REQUIRED TO BE WORN'' must be worn whenever the vessel is underway
and the intended wearer is not within an enclosed space.
* * * * *
(c) * * *
(1) Each Type V recreational hybrid PFD.
(2) Each Type V commercial hybrid PFD.
7. Section 160.077-7 is redesignated Sec. 160.077-4 and is revised
to read as follows:
Sec. 160.077-4 Type.
(a) Hybrid PFD's may be approved as a Type I, II, III, or V for
various ranges of persons weighing over 23 kg (50 lb), as Type I or II
for persons weighing 14-23 kg (30-50 lb) or as Type I or II for other
sizes which cross the foregoing size ranges and successfully pass all
applicable tests. A Type V PFD is a PFD that, unlike other PFD Types,
has limitations on its approval.
(b) The approval tests in this subpart require each Type V hybrid
PFD to have at least Type I, II, or III performance if permitted by its
intended size range.
(c) A hybrid PFD may be approved for use on recreational boats,
commercial vessels or both if the applicable requirements are met.
Sec. 160.077-9 [Redesignated as Sec. 160.077-5]
8. Section 160.077-9 is redesignated Sec. 160.077-5.
9. Section 160.077-11 is amended by revising paragraph (b)(1)(iii)
and the heading of paragraph (j) to read as follows:
Sec. 160.077-11 Materials--Recreational Hybrid PFD.
* * * * *
(b) * * *
(1) * * *
(iii) UL 1191 and having a V factor of 89 except that, foam with a
lower V factor may be used if compensated to provide equivalent
buoyancy which, after a normal service life, is not less than that of a
PFD made with material having a V factor of 89 and having the required
minimum inherent buoyancy when new; or
* * * * *
(j) Kapok pad covering. * * *
* * * * *
10. In Sec. 160.077-13, the heading is revised, and paragraph (d)
is removed and reserved.
Sec. 160.077-13 Materials--Commercial Hybrid PFD.
* * * * *
(d) [Reserved]
* * * * *
11. In Sec. 160.077-15, the heading is revised, paragraphs
(a)(2)(ii), (b)(3), (b)(13), (c)(2)(ii), and (d)(3) are revised, and
paragraph (b)(14), Table 160.077-15(b)(14) and paragraph (b)(15) are
added to read as follows:
Sec. 160.077-15 Construction and Performance--Recreational Hybrid PFD.
* * * * *
(a) * * *
(2) * * *
(ii) If it is to be marked as Type I or II, or Type V providing
Type I or II performance, not require second stage donning to achieve
that performance;
* * * * *
(b) * * *
(3) Have at least one automatic inflation mechanism that inflates
at least one chamber, if marked as providing Type I or II performance;
* * * * *
(13) If marked as a Type I, must have an attachment for a PFD light
securely fastened to the front shoulder area. The location should be
such that if the light is attached it will not damage or impair the
performance of the PFD.
(14) Provide the minimum buoyancies specified in Table 160.077-
15(b)(14).
Table 160.077-15(b)(14).--Buoyancy for Recreational Hybrid PFD's
----------------------------------------------------------------------------------------------------------------
Adult Youth Small child
----------------------------------------------------------------------------------------------------------------
Inherent Buoyancy (Deflated Condition):
Type I........................................... 70 N (15.5 lb) 50 N (11 lb) 40 N (9 lb)
Type II.......................................... 45 N (10 lb) 40 N (9 lb) 30 N (7 lb)
Type III......................................... 45 N (10 lb) 40 N (9 lb) N/A
Type V........................................... 33 N (7.5 lb) 34 N (7.5 lb) N/A
Total Buoyancy (Inflated Condition):
Type I........................................... 130 N (30 lb) 80 N (18 lb) 67 N (15 lb)
Type II.......................................... 100 N (22 lb) 67 N (15 lb) 53 N (12 lb)
Type III......................................... 100 N (22 lb) 67 N (15 lb) N/A
Type V........................................... 100 N (22 lb) 67 N (15 lb) N/A
----------------------------------------------------------------------------------------------------------------
(15) Meet any additional requirements that the Commandant may
prescribe, if necessary, to approve unique or novel designs.
(c) * * *
(2) * * *
(ii) Not be able to be locked in the open or closed position (a
friction-fit dust cap not being considered locking closed); and
* * * * *
(d) * * *
(3) The deflation mechanism may be the oral inflation mechanism.
* * * * *
12. In Sec. 160.077-17, the heading and paragraph (b)(4) are
revised, and paragraphs (b)(8), (9), and (10) and Table 160.077-
17(b)(10) are added to read as follows:
Sec. 160.077-17 Construction and Performance--Commercial Hybrid PFD.
* * * * *
(b) * * *
(4) Have at least one inflation chamber, unless marked as a SOLAS
lifejacket in which case it must have two inflation chambers;
* * * * *
(8) Be approved as universally sized as specified in Sec. 160.077-
15(b)(7).
(9) Each commercial hybrid PFD must have an attachment for a PFD
light securely fastened to the front shoulder area. The location should
be such that if the light is attached it will not damage or impair the
performance of the PFD
(10) In the deflated and the inflated condition, provide buoyancies
of at least the values in Table 160.077-17(b)(10).
Table 160.077-17(b)(10).--Minimum Buoyancy of Commercial Hybrid PFD's
----------------------------------------------------------------------------------------------------------------
Adult Youth Small child
----------------------------------------------------------------------------------------------------------------
Inherent Buoyancy (Deflated Condition):
Type I........................................... 70 N (15.5 lb) 50 N (11 lb) 40 N (9 lb)
Type V........................................... 60 N (13 lb) 34 N (7.5 lb) N/A
Total Buoyancy (Inflated Condition):
Type I........................................... 130 N (30 lb) 80 N (18 lb) 67 N (15 lb)
Type V........................................... 100 N (22 lb) 67 N (15 lb) N/A
----------------------------------------------------------------------------------------------------------------
* * * * *
13. In Sec. 160.077-19, paragraphs (b)(3)(iii), (b)(6), and (e) are
revised to read as follows:
Sec. 160.077-19 Approval Testing--Recreational Hybrid PFD.
* * * * *
(b) * * *
(3) * * *
(iii) Inflated flotation stability, 46 CFR 160.176-13(d)(2) through
(5) for Type I performance and UL 1517, section 15, for Type II and
Type III performance except comparisons are to be made to the
appropriate size reference vest as defined in Sec. 160.077-2(j).
* * * * *
(6) Buoyancy, buoyancy distribution, and inflation medium retention
test, UL 1517, sections 28 and 19, except:
(i) Recreational hybrid inflatables must provide minimum buoyancy
as specified in Table 160.077-15(b)(14):
(ii) The buoyancy and volume displacement of kapok buoyant inserts
must be tested in accordance with the procedures prescribed in
Sec. 160.047-4(c)(4) and Sec. 160.047-5(e)(1) in lieu of the procedures
in UL 1517, section 18 and 19.
* * * * *
(e) The Commandant may prescribe additional tests, if necessary, to
approve unique or novel designs.
14. In Sec. 160.077-21, the heading, paragraphs (c)(3), (c)(4)(ii),
and (g) are revised and paragraph (d)(3) is added to read as follows:
Sec. 160.077-21 Approval Testing--Commercial Hybrid PFD.
* * * * *
(c) * * *
(3) Buoyancy and inflation medium retention test, UL 1517, Section
S10, except the minimum buoyancies must be as specified in the Table
160.077-17(b)(10):
(4) * * *
(ii) Righting action test, UL 1517, section S8. In addition to
criteria stated in section S8, if a device has more than one chamber
the requirements in paragraph (d) of this section must be met after
each test with one of the chambers deflated.
(d) * * *
(3) The subject must have a freeboard of at least:
(i) 100 mm (4 inches) if marked as a Type I commercial hybrid PFD;
or
(ii) 120 mm (4.75 inches) if approved as a SOLAS lifejacket.
* * * * *
(g) The Commandant may prescribe additional tests, if necessary, to
approve unique or novel designs.
* * * * *
15. In Sec. 160.077-23, paragraphs (a)(2), (b)(1)(i), (b)(2)(ii),
(b)(2)(iv), (d)(4); (g)(2), (g)(3)(iii), (h)(4), (h)(5), (j)(4)(iii),
(k)(1), (k)(2), and notes (2) and (3) to Table 160.077-23B are revised,
and paragraphs (b)(2)(v) and (d)(5), and (g)(3)(x) are added to read as
follows:
Sec. 160.077-23 Production tests and inspections.
(a) * * *
(2) The Commandant may prescribe additional production tests and
inspections if needed to maintain quality control and check for
compliance with the requirements in this subpart.
(b) * * *
(1) * * *
(i) Perform all required tests and examinations on each PFD lot
before the independent laboratory inspector tests and inspects the lot,
except as discussed in Sec. 160.077-3(d)(5);
* * * * *
(2) * * *
(ii) Except as specified in paragraph (b)(2)(v) of this section, an
inspector must perform or supervise testing and inspection of at least
one PFD lot in each five lots produced.
(iii) * * *
(iv) Except as specified in paragraph (b)(2)(v) of this section, at
least once each calendar quarter, the inspector must, as a check on the
manufacturer's compliance with this section, examine the manufacturer's
records required by Sec. 160.077-25 and observe the manufacturer in
performing each of the tests required by paragraph (h) of this section.
(v) When less than six lots during any calendar year are produced
only one supervised lot inspection is required under paragraph
(b)(2)(ii) of this section, and one records examination and test
performance observation is required under paragraph (b)(2)(iv) of this
section during that year. Each lot tested and inspected must be within
seven lots of the previous lot inspected.
* * * * *
(d) * * *
(4) The number of samples selected per lot must be at least the
applicable number listed in Table 160.077-23A or Table 160.077-23B, as
applicable, except as allowed in paragraph (d)(5) of this section.
(5) When the total production for any five consecutive lots does
not exceed 250, manufacturer's and inspector's tests can be run on the
same sample(s) at the same time.
* * * * *
Table 160.077-23B Inspector's Sampling
*****
Notes to Table:
*****
(2) This test may be omitted if the manufacturer has previously
conducted it and the inspector has conducted the test on a previous
lot within the past year.
(3) One sample of each means of marking on each type of fabric or finish
used in PFD construction must be tested. This test is only required
when a new lot of materials is used. However, the test must be run at
least every six months regardless of whether a new lot of materials is
started within the past six months.
* * * * *
(g) * * *
(2) Calibration. The manufacturer must have the calibration of all
test equipment checked at least annually by a weights and measures
agency or the equipment manufacturer, distributor, or dealer.
(3) * * *
(iii) A Scale that has sufficient capacity to weigh a submerged
sample basket. The scale must be sensitive to 14 g (0.5 oz) and must
not have an error exceeding +/- 14 g (0.5 oz).
* * * * *
(x) Inflation Chamber Materials Test Equipment. If the required
tests in paragraph (h)(2) of this section are performed by the PFD
manufacturer, test equipment suitable for conducting Grab Breaking
Strength, Tear Strength, Permeability, and Seam Strength tests must be
available at the PFD manufacturer's facility.
* * * * *
(h) * * *
(4) Over-pressure. Each sample must be tested according to and meet
UL 1517, section 28. Test samples may be prestressed by inflating them
to a greater pressure than the required test pressure prior to
initiating the test at the specified values.
(5) Air Retention. Each sample must be tested according to and meet
UL 1517, section 36. Prior to initiating the test at the specified
values, test samples may be prestressed by inflating to a pressure
greater than the design pressure, but not exceeding 50 percent of the
required pressure for the tests in paragraph (h)(4) of this section.
Any alternate test method that decreases the length of the test must be
accepted by the Commandant and must require a proportionately lower
allowable pressure loss and the same percentage sensitivity and
accuracy as the standard allowable loss measured with the standard
instrumentation.
* * * * *
(j) * * *
(4) * * *
(iii) If the inspector rejects a lot, the Commandant must be
advised immediately.
(k) * * *
(1) A rejected PFD lot may be resubmitted for testing, examination,
or inspection if the manufacturer first removes and destroys each PFD
having the same type of defect or, if authorized by the Commandant or
an authorized representative of the Commandant, reworks the lot to
correct the defect.
(2) Any PFD rejected in a final lot examination or inspection may
be resubmitted for examination or inspection if all defects have been
corrected and reexamination or reinspection is authorized by the
Commandant or an authorized representative of the Commandant.
* * * * *
16. In Sec. 160.077-27, paragraph (a) is revised and paragraphs
(d), (e), and (f) are added to read as follows:
Sec. 160.077-27 Pamphlet.
(a) Each recreational hybrid PFD sold or offered for sale must be
provided with a pamphlet that a prospective purchaser can read prior to
purchase. The required pamphlet text must be printed verbatim and in
the sequence set out in paragraph (e) or (f) of this section, as
applicable. Additional information, instructions, or illustrations must
not be included within the required text. The type size shall be no
smaller than 8-point.
* * * * *
(d) The text specified in paragraphs (e)(2) and (f)(2) of this
section must be accompanied by illustrations of the types of devices
being described. The illustrations provided must be either photographs
or drawings of the manufacturer's own products or illustrations of
other USCG approved PFDs.
(e) For a Type I, II, and III recreational hybrid PFD the pamphlet
contents must be as follows:
(1) The text in UL 1517, Section 39, item A;
(2) The following text and illustrations:
There Are Five Types of Personal Flotation Devices
This is a Type [insert approved Type] Hybrid inflatable PFD.
Note: The following types of PFDs are designed to perform as
described in calm water and when the wearer is not wearing any other
flotation material (such as a wetsuit).
Type I--A Type I PFD has the greatest required inherent buoyancy
and turns most unconscious persons in the water from a face down
position to a vertical and slightly backward position, therefore,
greatly increasing one's chances of survival. The Type I PFD is
suitable for all waters, especially for cruising on waters where
there is a probability of delayed rescue, such as large bodies of
water where it is not likely that a significant number of boats will
be in close proximity. This type PFD is the most effective of all
types in rough water. It is reversible and available in only two
sizes--Adult (over 40 kg (90lb)) and child (less than 40 kg (90 lb))
which are universal sizes (designed for all persons in the
appropriate category).
[Insert Illustration of Type I PFD]
Type II--A Type II PFD turns most wearers to a vertical and
slightly backward position in the water. The turning action is not
as pronounced as with a Type I and the device will not turn as many
persons under the same conditions as the Type I. The Type II PFD is
usually more comfortable to wear than the Type I. This Type PFD is
normally sized for ease of emergency donning and is available in the
following sizes: Adult (over 40 kg (90 lb)), Medium Child (23-40 kg
(50-90 lb)), and two categories of Small Child (less than 23 kg (50
lb) or less than 14 kg (30 lb). Additionally, some models are sized
by chest sizes. You may prefer to use the Type II where there is a
probability of quick rescue such as areas where it is common for
other persons to be engaged in boating, fishing and other water
activities.
[Insert Illustration of Type II PFD]
Type III--The Type III PFD allows the wearer to assume a back of
vertical position, and the device will maintain the wearer in that
position and have no tendency to turn the wearer face down. It is
not designed to turn the wearer face up. A Type III is generally
more comfortable than a Type II, comes in a variety of styles which
should be matched to the individual use, and is often the best
choice for water sports, such as skiing, hunting, fishing, canoeing,
and kayaking. This Type PFD normally comes in many chest sizes and
weight ranges; however, some universal sizes are available. You may
also prefer to use the Type III where there is a probability of
quick rescue such as areas where it is common for other persons to
be engaged in boating, fishing, and other water activities.
[Insert Illustration of Type III PFD]
Hybrid Inflatable Type I, II, or III-- A Type I, II, or III
Hybrid PFD is an inflatable device which can be the most comfortable
and has a minimal amount of buoyancy when deflated and significantly
increased buoyancy when inflated (See accompanying table for actual
buoyancy for your Type of hybrid). When inflated it turns the wearer
with the action of a Type I, II, or III PFD as indicated on its
label. This type of PFD provides an extra degree of comfort to the
boater who will accept the responsibility for care of the device and
in-water trials to check its performance. The buoyancy provided by
this PFD when not inflated will not float approximately 90 percent
of the boating public. Therefore, it is not recommended for non-
swimmers unless worn with enough inflation to float the wearer. It
is suitable for use where there is or is not a probability of quick
rescue depending on the performance type marked on it. Type I
hybrids are suitable where rescue may be slow coming, while Types II
and III are good only when there is a chance of fast rescue. Type I
hybrids are approved in three weight ranges, adult, for persons
weighing over 40 kg (90 lb); youth, for persons weighing 23-40 kg
(50-90); and small child, for persons weighing 14-23 kg (30-50 lb).
Type II hybrid PFDs are approved in the same size ranges as Type I
hybrids but may be available in a number of chest sizes and in
universal adult sizes. Type III hybrids are only approved in adult
and youth sizes but may also be available in a number of chest sizes
and in universal adult sizes.''
[Insert Illustration of Hybrid PFD]
Type IV--A Type IV PFD is normally thrown or tossed to a person
who has fallen overbroad and is intended to be grasped and held by
the person until rescued. While the Type IV is acceptable in place
of a wearable device in certain instances, this type is suitable
only where there is a probability of quick rescue such as areas
where it is common for other persons to be engaged in boating,
fishing, and other water activities. It is not recommended for use
by non-swimmers and children.
[Insert Illustration of Type IV PFD]
Type V (General)--A Type V PFD is a PFD approved for restricted
uses or activities such as board sailing, or commercial white water
rafting. These PFDs are not usually suitable for other boating
activities. The label on the PFD indicates whether a particular
design of Type V PFD can be used in a specific application, what
restrictions or limitations apply, and its performance type.
Type V Hybrid--A Type V Hybrid PFD is an inflatable device which
can be the most comfortable and has a minimum deflated buoyancy and
significantly more buoyancy when inflated. In order for the device
to be acceptable for use on recreational boats, it must be worn
except when the boat is not underway or when the user is below deck.
When inflated it turns the wearer similar to the action provided by
a Type I, II, or III PFD (the type of performance is indicated on
the label). This type of PFD provides an extra degree of comfort to
the boater who will wear a PFD by having a reducd amount of inherent
buoyancy. However, the user must accept the responsibility for care
of the device and in-water trials to check its performance. The
buoyancy provided by this PFD when it is not inflated will float
approximately 70 percent of the boating public. Therefore, it is not
recommended for non-swimmers unless worn with enough inflation to
float the wearer. It is suitable for use where there is or is not a
probability of quick rescue depending on the performance type marked
on it. This type of PFD is approved in two sizes, adult, for persons
weighing over 40 kg (90 lb); and youth, for persons weighing 23-40
kg (50-90 lb), and may be available in a number of chest sizes and
in universal adult sizes.
(3) Insert a table with the applicable PFD Type, size, and buoyancy
values from Table 160.077-15(b)(14); and
(4) The text in UL 1517, Section 39, items D, E, and F.
(f) For a Type V recreational hybrid PFD the pamphlet contents must
be as follows:
(1) The text in UL 1517, Section 39, item A;
(2) The following text and illustrations:
There Are Five Types of Personal Flotation Devices
This is a Type [insert approved Type] Hybrid Inflatable PFD.
Note: The following types of PFDs are designed to perform as
described in calm water and when the wearer is not wearing any other
flotation material (such as a wetsuit).
Type I--A Type I PFD has the greatest required inherent buoyancy
and turns most unconscious persons in the water from a face down
position to a vertical and slightly backward position, therefore,
greatly increasing one's chances of survival. The Type I PFD is
suitable for all waters, especially for cruising on waters where
there is a probability of delayed rescue, such as large bodies of
water where it is not likely that a significant number of boats will
be in close proximity. This type PFD is the most effective of all
types in rough water. It is reversible and available in only two
sizes--Adult (over 40 kg (90 lb)) and child (less than 40 kg (90
lb.)) which are universal sizes (designed to for all persons in the
appropriate category).
[Insert Illustration of Type I PFD]
Type II--A Type II PFD turns most wearers to a vertical and
slightly backward position in the water. The turning action is not
as pronounced as with a Type I and the device will not turn as many
persons under the same conditions as the Type I. The Type II PFD is
usually more comfortable to wear than the Type I. This type PFD is
normally sized for ease of emergency donning and is available in the
following sizes: Adult (over 40 kg (90 lb)), Medium Child (23-40 kg
(50-90 lb)), and two categories of Small Child (less than 23 kg (50
lb) or less than 14 kg (30 lb)). Additionally, some models are sized
by chest sizes. You may prefer to use the Type II where there is a
probability of quick rescue such as areas where it is common for
other persons to be engaged in boating, fishing and other water
activities.
[Insert Illustration of Type II PFD]
Type III--The Type III PFD allows the wearer to assume a back of
vertical position, and the device will maintain the wearer in that
position and have no tendency to turn the wearer face down. It is
not designed to turn the wearer face up. A Type III is generally
more comfortable than Type II, comes in a variety of styles which
should be matched to the individual use, and is often the best
choice for water sports, such as skiing, hunting, fishing, canoeing,
and kayaking. This type PFD normally comes in many chest sizes and
weight ranges; however, some universal sizes are available. You may
also prefer to use the Type III where there is a probability of
quick rescue such as areas where it is common for other persons to
be engaged in boating, fishing, and other water activities.
[Insert Illustration of Type III PFD]
Hybrid Inflatable Type I, II, or III--A Type I, II, or III
Hybrid PFD is an inflatable device which can be the most comfortable
and has a minimal amount of buoyancy when deflated and significantly
increased buoyancy when inflated (See accompanying table for actual
buoyancy for your Type of hybrid). When inflated it turns the wearer
with the action of a Type I, II, or III PFD as indicated on its
label. This type of PFD provides an extra degree of comfort to the
boater who will accept the responsibility for care of the device and
in-water trials to check its performance. The buoyancy provided by
this PFD when not inflated will float approximately 90 percent of
the boating public. Therefore, it is not recommended for non-
swimmers unless worn with enough inflation to float the wearer. It
is suitable for use where there is or is not a probability of quick
rescue depending on the performance type marked on it. Type I
hybrids are suitable where rescue may be slow coming, while Type II
and III are good only when there is a chance of fast rescue. Type I
hybrids are approved in three weight ranges, adult, for persons
weighing over 40 kg (90 lb); youth, for persons weighing 23-40 kg
(50-90 lb); and small child, for persons weighing 14-23 kg (30-50
lb). Type II hybrid PFDs are approved in the same size ranges as
Type I hybrids but may be available in a number of chest sizes and
in universal adult sizes. Type III hybrids are only approved in
adult and youth sizes but may also be available in a number of chest
sizes and in universal adult sizes.
Type IV--A Type IV PFD is normally thrown or tossed to a person
who has fallen overboard and is intended to be grasped and held by
the person until rescued. While the Type IV is acceptable in place
of a wearable device in certain instances, this type is suitable
only where there is a probability of quick rescue such as areas
where it is common for other persons to be engaged in boating,
fishing, and other water activities. It is not recommended for use
by non-swimmers and children.
[Insert Illustration of Type IV PFD]
Type V (General)--A Type V PFD is a PFD approved for restricted
uses or activities such as board sailing, or commercial white water
rafting. These PFDs are not usually suitable for other boating
activities. The label on the PFD indicates whether a particular
design of Type V PFD can be used in a specific application, what
restrictions or limitations apply, and its performance type.
Type V Hybrid--A Type V Hybrid PFD is an inflatable device which
can be the most comfortable and has a minimum of [insert the
applicable minimum deflated and inflated values from Table 160.077-
15(b)(14) for adult and youth sizes]. In order for the device to be
acceptable for use on recreational boats, it must be worn except
when the boat is not underway or when the user is below deck. When
inflated it turns the wearer similar to the action provided by a
Type I, II, or III PFD (the type of performance is indicated on the
label). This type of PFD provides an extra degree of comfort to the
boater who will wear a PFD by having a reduced amount of inherent
buoyancy. However, the user must accept the responsibility for care
of the device and inwater trials to check its performance. The
buoyancy provided by this PFD when it is not inflated will float
approximately 70 percent of the boating public. Therefore, it is not
recommended for non-swimmers unless worn with enough inflation to
float the wearer. It is suitable for use where there is or is not a
probability of quick rescue depending on the performance type marked
on it. This type of PFD is approved in two sizes, adult, for persons
weighing over 40 kg (90 lb); and youth, for persons weighing 23-40
kg (50-90 lb), and may be available in a number of chest sizes and
in universal adult sizes.
[Insert Illustration of Hybrid PFD]
(3) Insert a table with the applicable PFD Type, size, and buoyancy
values from Table 160.077-15(b)(14); and
(4) The text in UL 1517, Section 39, items C, D, E, and F.
17. In Sec. 160.077-29, paragraphs (b) and (c) are revised, and
paragraphs (d), (e) and (f) are added to read as follows:
Sec. 160.077-29 PFD manuals.
(a) ***
(b) Manual Contents. Each recreational and commercial hybrid PFD
sold or offered for sale must be provided with an owner's manual for
its PFD Type. The manual text for a recreational hybrid PFD must be
printed verbatim and in the sequence set out in paragraph (c) or (d) of
this section, as applicable. The manual for a commercial hybrid PFD
must meet the requirements of paragraph (f) of this section. Additional
information, instructions, or illustrations may be included within the
required text if there is no contradiction to the required information.
(c) Type I, II or III Recreation Hybrid PFD. For a Type I, II, and
III recreation hybrid PFD the manual contents must be as follows:
(1) The following text:
Hybrid Limitations
This PFD has limited inherent buoyancy which means YOU MAY HAVE
TO INFLATE IT TO FLOAT, and the inflatable portion requires
maintenance. In the event of an accident or fall overboard, the
chance of any PFD aiding in your survival are greatly increased if
it is worn. Wearing this PFD makes its limitation much less
significant.
There is only one way to find out if you will float without
inflation. That is to try this PFD in the water as explained in
[insert reference to the section of the manual that discusses how to
test the PFD]. If you have not tested this device in accordance with
these guidelines, the Coast Guard does not recommend it use.
(2) Instructions on use including instructions on donning,
inflation, replenishing inflation mechanisms, and recommended practice
operation;
(3) Instructions on how to properly inspect and maintain the PFD,
and recommendations concerning frequency of inspection;
(4) Instructions on how to get the PFD repaired;
(5) The text in UL 1517, Section 40, items B and D;
(6) The following text:
Why Do You Need a PFD?
A PFD provides buoyancy to help keep your head above water and
to help you stay face up. The average in-water-weight of an adult is
only about 5 to 10 pounds. The buoyancy provided by most PFDs will
support that weight in water. However, the hybrid Type I, II, or III
PFD may be an exception. The uninflated buoyancy provided by this
PFD may only float 90 percent of the boating public. This is because
the inherent buoyancy has been reduced to make it more comfortable
to wear. So, you may not float adequately without inflating the
device. Once the device is inflated you will have a minimum of 22 lb
of buoyancy for adult sizes, which is more than enough to float
everyone. (See table above [below] for the actual minimum buoyancy
for different Types of hybrids.) Your body weight alone does not
determine your in-water-weight. Since there is no simple method of
determining your weight in water, you should try the device in the
water in both it's deflated and inflated condition.
(7) The text in UL 1517, Section 40, item G;
(8) The following text:
Wear Your PFD
Your PFD won't help you if you don't have it on. It is well-
known that most boating accidents occur on calm water during a clear
sunny day. It is also true that in approximately 80 percent of all
boating accident fatalities, the victim did not use a PFD. Don't
wait until it's too late. Non-swimmers and children especially
should wear their PFD at all times when on or near the water. Hybrid
Type I, II, III or V PFDs are not recommended for non-swimmers
unless inflated enough to float the wearer.
(9) The text in UL 1517, Section 40, items I, J, K, and L; and
(10) Insert a table with the applicable PFD Type, size, and
buoyancy values from Table 160.077-15(b)(14) or provide a reference to
appropriate pamphlet table, if the pamphlet is combined with the
manual.
(d) Type V Recreational Hybrid PFD. For a Type V recreational
hybrid PFD the manual contents must be as follows:
(1) The text in UL 1517, Section 40, item A;
(2) Instructions on use including instructions on donning,
inflation, replenishing inflation mechanisms, and recommended practice
operation;
(3) Instructions on how to properly inspect and maintain the PFD,
and recommendations concerning frequency of inspection;
(4) Instructions on how to get the PFD repaired; and
(5) The text in UL 1517, section 40, that is not included under
paragraph (d)(1) of this section.
(e) Sale with manual. No person may sell or offer for sale a
recreational hybrid PFD unless the manual required by this section is
provided with it.
(f) Commercial Hybrid PFD. (1) For a commercial hybrid PFD that is
``Required To Be Worn'' the manual must meet the requirements of
paragraph (d) of this section.
(2) For a commercial hybrid PFD approved as a ``Work Vest Only'' or
Type I PFD the manual must meet the requirements of either paragraphs
(f) (3) and (4) or of paragraph (c) of this section, titled Type I, II,
or III Recreational Hybrid PFD.
(3) Each commercial hybrid PFD approved with special purpose
limitation must have a user's manual that--
(i) Explains in detail the proper care, maintenance, stowage, and
use of the PFD; and
(ii) Includes any other safety information as prescribed by the
approval certificate.
(4) If the manual required in paragraph (f)(3) of this section
calls for inspection or service by vessel personnel, the manual must--
(i) Specify personnel training or qualifications needed;
(ii) Explain how to identify the PFDs that need to be inspected;
and
(iii) Have an inspection and service log, unless the information is
otherwise recorded.
(5) If a PFD light approved under subpart 161.012 is not provided
at time of sale, the manual must specify the recommended type of light
to be used.
18. In Sec. 160.077-30, paragraphs (a) and (b) are revised to read
as follows:
Sec. 160.077-30 Spare operating components and temporary marking.
(a) Spare operating components. Each recreational and commercial
hybrid PFD must--
(1) If it has a manual or automatic inflation mechanism and is
packaged and sold with one inflation medium cartridge loaded into the
inflation mechanism, have at least two additional spare inflation
cartridges packaged with it. If it is sold without an inflation medium
cartridge loaded into the inflation mechanism, it must be packaged and
sold with at least three cartridges; and
(2) If it has an automatic inflation mechanism and is packaged and
sold with one water sensitive element loaded into the inflation
mechanism, have at least two additional spare water sensitive elements
packaged with it. If it is sold without a water sensitive element
loaded into the inflation mechanism, it must be packaged and sold with
at least three water sensitive elements.
(b) Temporary marking. Each recreational and commercial hybrid PFD
which is sold--
(1) In a ready-to-use condition but, which has covers or restraints
to inhibit tampering with the inflation mechanism prior to sale, must
have any such covers or restraints conspicuously marked ``REMOVE
IMMEDIATELY AFTER PURCHASE.'' or
(2) Without an inflation medium cartridge, a water sensitive
element, or both pre-loaded into the inflation mechanism, must include
the markings required in Sec. 160.077-15(c)(3)(ii).
19. In Sec. 160.077-31, paragraphs (c), (d), (g)(1), (h), (j),
introductory text, (j)(1), and (k) are revised, paragraph (l) is added,
and paragraph (e)(5) is removed and reserved to read as follows:
Sec. 160.077-31 PFD Marking.
* * * * *
(c) Recreational Hybrid PFD. Each recreational hybrid PFD must be
marked with the following text using capital letters where shown and be
presented in the exact order shown:
[see paragraph (l) of this section for exact text to be used
here]
Type [I, II, III, or V, as applicable] PFD: Recreational hybrid
inflatable--Approved for use only on recreational boats. [For Type V
only] REQUIRED TO BE WORN to meet Coast Guard carriage requirements
(except for persons in enclosed spaces as explained in owner's
manual).
You May Have To Inflate This PFD To Float.
This PFD requires maintenance.
Try this PFD in the water to see if it will float you without
inflation.
[For Type V only] When inflated this PFD provides performance
equivalent to a (see paragraph (h) of this section for exact test to
be used here).
When new, this PFD provides a minimum buoyant force of [see
Table 160.077-15(b)(14) for appropriate value to be used here]
uninflated and [see Table 160.077-15(b)(14) for appropriate value to
be used here] when inflated.
A pamphlet and owner's manual must be provided with this PFD.
(d) Commercial Hybrid PFD. Each commercial hybrid PFD must be
marked with the following text using capital letters where shown and be
presented in the exact order shown:
[see paragraph (l) (1) or (2) of this section for exact text to
be used here]
Type [``I'' or ``V Work Vest Only'', as applicable] PFD:
Commercial hybrid inflatable--Approved for use on [see paragraph (j)
of this section for exact text to be used here].
You May Have To Inflate This PFD To Float.
This PFD must be maintained, stowed, and used only in accordance
with the owner's manual.
Try this PFD in the water to see if it will float you without
inflation.
[For Type V only] When inflated this PFD provides performance
equivalent to a (see paragraph (h) of this section for exact test to
be used here).
When new, this PFD provides a minimum buoyant force of [see
Table 160.077-17(b)(9) for appropriate value to be used here]
uninflated and [see Table 160.077-17(b)(9) for appropriate value to
be used here] when inflated.
(e) * * *
(5) [Reserved]
* * * * *
(g) Flotation material buoyancy loss--(1) Foam. When flotation foam
having a V factor of less than 94 is used, the statement ``As explained
in the owner's manual, test at least annually for buoyancy loss.'' must
follow the minimum buoyant force statement in paragraph (c) or (d) of
this section.
(2) * * *
(h) Type equivalence. The exact text to be inserted for Type V
hybrid PFD's will be one of the following type equivalents as noted on
the Approval Certificate.
* * * * *
(j) Approved use. Unless the Commandant has authorized omitting the
display of approved use, the exact text to be inserted will be one or
more of the following statements as noted on the approval certificate.
(1) ``uninspected commercial vessels,''
(a) ``Type I Hybrid PFD'' or
(b) ``Type V Hybrid PFD--required to be worn to meet Coast Guard
carriage requirements (except for persons in enclosed spaces as
explained in owner's manual).''
* * * * *
(k) Statement of minimum uninflated buoyancy. Instead of the
statement concerning minimum buoyancy required by paragraphs (c) and
(d) of this section, a hybrid PFD may be marked with a minimum buoyant
force of greater than the values on Table 160.077-15(b)(14) for
recreational hybrid PFD's or Table 160.077-17(b)(10) for commercial
hybrid PFD's, if specified on the approved plans and specifications.
(l) Size ranges. (1) Adult--For persons weighing more than 40 kg
(90 lb).
(2) Youth--For persons weighing 23-40 kg (50-90 lb).
(3) Child Small--For persons weighing 14-23 kg (30-50 lb).
20. Section 160.077-33 is redesignated Sec. 160.077-6, and in newly
redesignated Sec. 160.077-6 paragraphs (b), introductory text, and
(c)(1) are revised, and paragraph (a)(3)(vi) is added to read as
follows:
Sec. 160.077-6 Approval Procedures.
(a) * * *
(3) * * *
(vi) The intended size range of wearer.
* * * * *
(b) Waiver of tests. If a manufacturer requests that any test in
this subpart be waived, one of the following must be provided to the
Commandant as justification for the waiver:
* * * * *
(c) * * *
(1) Meets other requirements prescribed by the Commandant in place
of or in addition to requirements in this subpart; and
* * * * *
21. Section 160.077-35 is redesignated Sec. 160.077-7 and in newly
redesignated Sec. 160.077-7, paragraphs (a) and (b) are revised to read
as follows:
Sec. 160.077-7 Procedure for approval of design or material revision.
(a) Each change in design, material, or construction of an approved
PFD must be approved by the Commandant before being used in any
production of PFD's.
(b) Determinations of equivalence of design, construction, and
materials may be made only by the Commandant.
22. Section 160.077-37 is redesignated Sec. 160.077-9 and is
revised to read as follows:
Sec. 160.077-9 Independent laboratories.
A list of independent laboratories which have been accepted by the
Commandant for conduction or supervision the tests and inspections
required by this subpart, and for making material certifications
required by Sec. 160.077-11, may be obtained from the Commandant.
Dated: January 11, 1994.
A.E. Henn,
Rear Admiral, U.S. Coast Guard, Chief, Office of Marine Safety,
Security and Environmental Protection.
[FR Doc. 94-1135 Filed 1-14-94; 8:45 am]
BILLING CODE 4910-14-M
This is a copy of a public record, reproduced as it was published. It is not legal advice, and it may not be the version a court would rely on. Check the official source before you cite it.