# 46 CFR § 153.219: Access to double bottom tanks serving as dedicated ballast tanks

> Federal · Regulations · In force

URL: https://www.frixlaw.com/law-library/statutes/ecfr-46-153.219

## Section

- **Citation:** 46 CFR § 153.219
- **Heading:** Access to double bottom tanks serving as dedicated ballast tanks
- **Jurisdiction:** Federal
- **Kind:** Regulations
- **Status:** In force
- **Text as of:** September 22, 2026
- **Source:** Publisher's official text
- **Location:** Title 46—Shipping > CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY > SUBCHAPTER O—CERTAIN BULK DANGEROUS CARGOES > PART 153—SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS > Subpart B—Design and Equipment > General Vessel Requirements

## Text

(a) Except as prescribed in paragraph (b) of this section, access openings to double bottom tanks serving as dedicated ballast tanks must not be located within a cargo containment system.
(b) Each access opening to a double bottom tank that is a dedicated ballast tank and that is located within a cargo containment system must be:
(1) Enclosed in an access trunk extending to the weatherdeck;
(2) Separated from the cargo containment system by two manhole coverings; or
(3) Approved by the Commandant (CG-ENG).
[CGD 78-128, 47 FR 21207, May 17, 1982, as amended by CGD 82-063b, 48 FR 4782, Feb. 3, 1983]

## Nearby sections

- [46 CFR § 153.190 § 153.190 Stability requirements.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.190.md)
- [46 CFR § 153.201 § 153.201 Openings to accommodation, service or control spaces.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.201.md)
- [46 CFR § 153.208 § 153.208 Ballast equipment.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.208.md)
- [46 CFR § 153.209 § 153.209 Bilge pumping systems.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.209.md)
- [46 CFR § 153.214 § 153.214 Personnel emergency and safety equipment.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.214.md)
- [46 CFR § 153.215 § 153.215 Safety equipment lockers.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.215.md)
- [46 CFR § 153.216 § 153.216 Shower and eyewash fountains.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.216.md)
- [46 CFR § 153.217 § 153.217 Access to enclosed spaces and dedicated ballast tanks.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.217.md)
- [46 CFR § 153.219 § 153.219 Access to double bottom tanks serving as dedicated ballast tanks.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.219.md)
- [46 CFR § 153.230 § 153.230 Type I system.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.230.md)
- [46 CFR § 153.231 § 153.231 Type II system.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.231.md)
- [46 CFR § 153.232 § 153.232 Type III system.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.232.md)
- [46 CFR § 153.233 § 153.233 Separation of tanks from machinery, service and other spaces.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.233.md)
- [46 CFR § 153.234 § 153.234 Fore and aft location.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.234.md)

---