# 46 CFR § 153.208: Ballast equipment

> Federal · Regulations · In force

URL: https://www.frixlaw.com/law-library/statutes/ecfr-46-153.208

## Section

- **Citation:** 46 CFR § 153.208
- **Heading:** Ballast equipment
- **Jurisdiction:** Federal
- **Kind:** Regulations
- **Status:** In force
- **Text as of:** September 22, 2026
- **Source:** Publisher's official text
- **Location:** Title 46—Shipping > CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY > SUBCHAPTER O—CERTAIN BULK DANGEROUS CARGOES > PART 153—SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS > Subpart B—Design and Equipment > General Vessel Requirements

## Text

(a) Except for the arrangement described in paragraph (b) of this section no piping that serves a dedicated ballast tank that is adjacent to a cargo tank may enter an engine room or accommodation space.
(b) Piping used only to fill a dedicated ballast tank adjacent to a cargo tank may enter an engine room or accommodation space if the piping has a valve or valving arrangement:
(1) Within the part of the tankship where a containment system may be located under § 153.234;
(2) That allows liquid to flow only towards that ballast tank (such as a check valve); and
(3) That enables a person to shut off the fill line from the weatherdeck (such as a stop valve).
(c) Except as prescribed in paragraph (d) of this section, pumps, piping, vent lines, overflow tubes and sounding tubes serving dedicated ballast tanks must not be located within a cargo containment system.
(d) Each vent line, overflow tube and sounding tube that serves a dedicated ballast tank and that is located within a cargo containment system must meet § 32.60-10(e)(2) of this chapter.
[CGD 73-96, 42 FR 49027, Sept. 26, 1977, as amended by CGD 78-128, 47 FR 21207, May 17, 1982]

## Nearby sections

- [46 CFR § 153.190 § 153.190 Stability requirements.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.190.md)
- [46 CFR § 153.201 § 153.201 Openings to accommodation, service or control spaces.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.201.md)
- [46 CFR § 153.208 § 153.208 Ballast equipment.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.208.md)
- [46 CFR § 153.209 § 153.209 Bilge pumping systems.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.209.md)
- [46 CFR § 153.214 § 153.214 Personnel emergency and safety equipment.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.214.md)
- [46 CFR § 153.215 § 153.215 Safety equipment lockers.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.215.md)
- [46 CFR § 153.216 § 153.216 Shower and eyewash fountains.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.216.md)
- [46 CFR § 153.217 § 153.217 Access to enclosed spaces and dedicated ballast tanks.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.217.md)
- [46 CFR § 153.219 § 153.219 Access to double bottom tanks serving as dedicated ballast tanks.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.219.md)
- [46 CFR § 153.230 § 153.230 Type I system.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.230.md)
- [46 CFR § 153.231 § 153.231 Type II system.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.231.md)
- [46 CFR § 153.232 § 153.232 Type III system.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.232.md)
- [46 CFR § 153.233 § 153.233 Separation of tanks from machinery, service and other spaces.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.233.md)
- [46 CFR § 153.234 § 153.234 Fore and aft location.](https://www.frixlaw.com/law-library/statutes/ecfr-46-153.234.md)

---

Source: Frix Law Library, https://www.frixlaw.com/law-library/statutes/ecfr-46-153.208. Check the current official text before relying on it. Not legal advice.