# 14 CFR § 27.619: Special factors

> Federal · Regulations · In force

URL: https://www.frixlaw.com/law-library/statutes/ecfr-14-27.619

## Section

- **Citation:** 14 CFR § 27.619
- **Heading:** Special factors
- **Jurisdiction:** Federal
- **Kind:** Regulations
- **Status:** In force
- **Text as of:** September 22, 2026
- **Source:** Publisher's official text
- **Location:** Title 14—Aeronautics and Space > CHAPTER I—FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION > SUBCHAPTER C—AIRCRAFT > PART 27—AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT > Subpart D—Design and Construction > General

## Text

(a) The special factors prescribed in §§ 27.621 through 27.625 apply to each part of the structure whose strength is—
(1) Uncertain;
(2) Likely to deteriorate in service before normal replacement; or
(3) Subject to appreciable variability due to—
(i) Uncertainties in manufacturing processes; or
(ii) Uncertainties in inspection methods.
(b) For each part to which §§ 27.621 through 27.625 apply, the factor of safety prescribed in § 27.303 must be multiplied by a special factor equal to—
(1) The applicable special factors prescribed in §§ 27.621 through 27.625; or
(2) Any other factor great enough to ensure that the probability of the part being understrength because of the uncertainties specified in paragraph (a) of this section is extremely remote.

## Nearby sections

- [14 CFR § 27.601 § 27.601 Design.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.601.md)
- [14 CFR § 27.602 § 27.602 Critical parts.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.602.md)
- [14 CFR § 27.603 § 27.603 Materials.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.603.md)
- [14 CFR § 27.605 § 27.605 Fabrication methods.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.605.md)
- [14 CFR § 27.607 § 27.607 Fasteners.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.607.md)
- [14 CFR § 27.609 § 27.609 Protection of structure.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.609.md)
- [14 CFR § 27.610 § 27.610 Lightning and static electricity protection.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.610.md)
- [14 CFR § 27.611 § 27.611 Inspection provisions.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.611.md)
- [14 CFR § 27.613 § 27.613 Material strength properties and design values.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.613.md)
- [14 CFR § 27.619 § 27.619 Special factors.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.619.md)
- [14 CFR § 27.621 § 27.621 Casting factors.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.621.md)
- [14 CFR § 27.623 § 27.623 Bearing factors.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.623.md)
- [14 CFR § 27.625 § 27.625 Fitting factors.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.625.md)
- [14 CFR § 27.629 § 27.629 Flutter.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.629.md)

---

Source: Frix Law Library, https://www.frixlaw.com/law-library/statutes/ecfr-14-27.619. Check the current official text before relying on it. Not legal advice.
