# 14 CFR § 27.610: Lightning and static electricity protection

> Federal · Regulations · In force

URL: https://www.frixlaw.com/law-library/statutes/ecfr-14-27.610

## Section

- **Citation:** 14 CFR § 27.610
- **Heading:** Lightning and static electricity protection
- **Jurisdiction:** Federal
- **Kind:** Regulations
- **Status:** In force
- **Text as of:** September 22, 2026
- **Source:** Publisher's official text
- **Location:** Title 14—Aeronautics and Space > CHAPTER I—FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION > SUBCHAPTER C—AIRCRAFT > PART 27—AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT > Subpart D—Design and Construction > General

## Text

(a) The rotorcraft must be protected against catastrophic effects from lightning.
(b) For metallic components, compliance with paragraph (a) of this section may be shown by—
(1) Electrically bonding the components properly to the airframe; or
(2) Designing the components so that a strike will not endanger the rotorcraft.
(c) For nonmetallic components, compliance with paragraph (a) of this section may be shown by—
(1) Designing the components to minimize the effect of a strike; or
(2) Incorporating acceptable means of diverting the resulting electrical current so as not to endanger the rotorcraft.
(d) The electrical bonding and protection against lightning and static electricity must—
(1) Minimize the accumulation of electrostatic charge;
(2) Minimize the risk of electric shock to crew, passengers, and service and maintenance personnel using normal precautions;
(3) Provide an electrical return path, under both normal and fault conditions, on rotorcraft having grounded electrical systems; and
(4) Reduce to an acceptable level the effects of static electricity on the functioning of essential electrical and electronic equipment.
[Amdt. 27-21, 49 FR 44433, Nov. 6, 1984, as amended by Amdt. 27-37, 64 FR 45094, Aug. 18, 1999; Amdt. 27-46, 76 FR 33135, June 8, 2011]

## Nearby sections

- [14 CFR § 27.601 § 27.601 Design.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.601.md)
- [14 CFR § 27.602 § 27.602 Critical parts.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.602.md)
- [14 CFR § 27.603 § 27.603 Materials.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.603.md)
- [14 CFR § 27.605 § 27.605 Fabrication methods.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.605.md)
- [14 CFR § 27.607 § 27.607 Fasteners.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.607.md)
- [14 CFR § 27.609 § 27.609 Protection of structure.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.609.md)
- [14 CFR § 27.610 § 27.610 Lightning and static electricity protection.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.610.md)
- [14 CFR § 27.611 § 27.611 Inspection provisions.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.611.md)
- [14 CFR § 27.613 § 27.613 Material strength properties and design values.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.613.md)
- [14 CFR § 27.619 § 27.619 Special factors.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.619.md)
- [14 CFR § 27.621 § 27.621 Casting factors.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.621.md)
- [14 CFR § 27.623 § 27.623 Bearing factors.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.623.md)
- [14 CFR § 27.625 § 27.625 Fitting factors.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.625.md)
- [14 CFR § 27.629 § 27.629 Flutter.](https://www.frixlaw.com/law-library/statutes/ecfr-14-27.629.md)

---

Source: Frix Law Library, https://www.frixlaw.com/law-library/statutes/ecfr-14-27.610. Check the current official text before relying on it. Not legal advice.