## Text

An inspection of the exterior includes the visible wall coverings, trim, protective coatings and sealants, windows and doors, attached porches, decks, steps, balconies, handrails, guardrails, carports, eaves, soffits, fascias and visible exterior portions of chimneys.
(1) The inspector will:
• Describe the exterior components visible from ground level.
• Inspect visible wall coverings, trim, protective coatings and sealants, windows and doors, attached porches, decks, steps, balconies, handrails, guardrails, carports, eaves, soffits, fascias and visible exterior portions of chimneys.
• Probe exterior components where deterioration is suspected or where clear indications of possible deterioration exist. Probing is not required when probing will damage any finished surface or where no deterioration is suspected.
• Describe any deficiencies of these systems or components.
(2) The inspector is not required to:
• Inspect
(a) Buildings, decks, patios, fences, retaining walls, and other structures detached from the dwelling.
(b) Safety type glass or the integrity of thermal window seals.
(c) Flues or verify the presence of flue liners beyond what can be safely and readily seen from the roof or the firebox of a stove or fireplace.
• Test or evaluate the operation of security locks, devices or systems.
• Enter areas beneath decks with less than five feet of clearance from the underside of joists to grade.
• Evaluate the function or condition of shutters, awnings, storm doors, storm windows, screens, and similar accessories.

## Nearby sections

- [WAC 308-408C-010 WAC 308-408C-010. Standards of practice (SOP)—Purpose and scope](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_308_408C_010.md)
- [WAC 308-408C-020 WAC 308-408C-020. Ethics — Statement of purpose](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_308_408C_020.md)
- [WAC 308-408C-030 WAC 308-408C-030. Exclusions and limitations](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_308_408C_030.md)
- [WAC 308-408C-040 WAC 308-408C-040. Recordkeeping](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_308_408C_040.md)
- [WAC 308-408C-050 WAC 308-408C-050. Contracts](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_308_408C_050.md)
- [WAC 308-408C-060 WAC 308-408C-060. Procedures](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_308_408C_060.md)
- [WAC 308-408C-070 WAC 308-408C-070. Structure](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_308_408C_070.md)
- [WAC 308-408C-080 WAC 308-408C-080. Exterior](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_308_408C_080.md)
- [WAC 308-408C-090 WAC 308-408C-090. Roofs](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_308_408C_090.md)
- [WAC 308-408C-100 WAC 308-408C-100. Plumbing system](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_308_408C_100.md)
- [WAC 308-408C-110 WAC 308-408C-110. Electrical system](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_308_408C_110.md)
- [WAC 308-408C-120 WAC 308-408C-120. Heating system](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_308_408C_120.md)
- [WAC 308-408C-130 WAC 308-408C-130. Air conditioning systems](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_308_408C_130.md)
- [WAC 308-408C-140 WAC 308-408C-140. Interiors](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_308_408C_140.md)

---

Source: Frix Law Library, https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_308_408C_080. Check the current official text before relying on it. Not legal advice.