## Text

Calculating fall clearance distance using a shock-absorbing lanyard and D-ring anchorage connector - Nonmandatory guidelines for complying with WAC 296-880-40020 .
Do the following to calculate the fall clearance distance using a shock-absorbing lanyard and D-ring anchorage connector:
(1) First, add the length of the shock-absorbing lanyard (six feet) to the maximum elongation of the shock absorber during deceleration (three and one-half feet) to the average height of a worker (six feet);
(2) Then, add a safety factor of three feet to allow for the possibility of an improperly fit full body harness, a taller than average worker and/or a miscalculation of distance.
Note:
The suggested safe fall clearance distance for this example is eighteen and one-half feet.

## Nearby sections

- [WAC 296-880-080 WAC 296-880-080. Scope](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_880_080.md)
- [WAC 296-880-090 WAC 296-880-090. Quick reference guide](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_880_090.md)
- [WAC 296-880-095 WAC 296-880-095. Definitions](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_880_095.md)
- [WAC 296-880-100 WAC 296-880-100. Application](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_880_100.md)
- [WAC 296-880-200 WAC 296-880-200. Fall protection required at four feet or more](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_880_200.md)
- [WAC 296-880-300 WAC 296-880-300. Specific fall protection requirements](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_880_300.md)
- [WAC 296-880-400 WAC 296-880-400. Fall protection system specifications](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_880_400.md)
- [WAC 296-880-500 WAC 296-880-500. Appendix A — Determining roof widths — Nonmandatory guidelines](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_880_500.md)
- [WAC 296-880-505 WAC 296-880-505. Appendix B — Calculating fall clearance distance — Nonmandatory guidelines](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_880_505.md)
- [WAC 296-880-510 WAC 296-880-510. Appendix C — Test methods and additional guidelines for personal fall arrest systems — Nonmandatory guidelines](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_880_510.md)
- [WAC 296-880-10005 WAC 296-880-10005. General requirements](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_880_10005.md)
- [WAC 296-880-10010 WAC 296-880-10010. Fall protection required regardless of height](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_880_10010.md)
- [WAC 296-880-10015 WAC 296-880-10015. Training](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_880_10015.md)
- [WAC 296-880-10020 WAC 296-880-10020. Fall protection work plan required at ten feet or more](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_880_10020.md)

---

Source: Frix Law Library, https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_880_505. Check the current official text before relying on it. Not legal advice.