## Text

(1) You must ensure that chain and electric hoists are of what is known as "all steel construction." No cast iron may be used in parts subject to tension except drums, bearings or brake shoes.
(2) You must ensure that the chains are made of the best quality steel or iron with welded links.
(3) You must ensure that chain and electric hoists have a factor of safety of at least 5.
(4) You must ensure that chain and electric hoists are equipped with an approved device which will automatically lock the load when hoisting is stopped.
(5) You must ensure that electric hoists are provided with an approved limit stop to prevent the hoist block from traveling too far in case the operating handle is not released in time.

## Nearby sections

- [WAC 296-24-003 WAC 296-24-003. Subsections, subdivisions, items, subitems, and segments](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_24_003.md)
- [WAC 296-24-005 WAC 296-24-005. Purpose and scope](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_24_005.md)
- [WAC 296-24-012 WAC 296-24-012. Definitions applicable to all sections of this chapter](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_24_012.md)
- [WAC 296-24-237 WAC 296-24-237. Construction, operation and maintenance — Chain and electric hoists](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_24_237.md)
- [WAC 296-24-238 WAC 296-24-238. Air hoists](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_24_238.md)
- [WAC 296-24-293 WAC 296-24-293. "A" frames](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_24_293.md)
- [WAC 296-24-325 WAC 296-24-325. Nitrous oxide](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_24_325.md)
- [WAC 296-24-450 WAC 296-24-450. Chlorine cylinders used in chlorinator systems](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_24_450.md)
- [WAC 296-24-567 WAC 296-24-567. Employee emergency plans and fire prevention plans](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_24_567.md)
- [WAC 296-24-592 WAC 296-24-592. Portable fire extinguishers](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_24_592.md)
- [WAC 296-24-602 WAC 296-24-602. Standpipe and hose systems](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_24_602.md)
- [WAC 296-24-607 WAC 296-24-607. Automatic sprinkler systems](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_24_607.md)
- [WAC 296-24-617 WAC 296-24-617. Fixed extinguishing systems, general](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_24_617.md)
- [WAC 296-24-622 WAC 296-24-622. Fixed extinguishing systems, dry chemical](https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_24_622.md)

---

Source: Frix Law Library, https://www.frixlaw.com/law-library/statutes/STATE_WA_ADC_296_24_237. Check the current official text before relying on it. Not legal advice.