# 62 Ill. Adm. Code 300.220: Section 300.220 Monitoring

> Illinois · Regulations · In force

URL: https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P300_S300_220

## Section

- **Citation:** 62 Ill. Adm. Code 300.220
- **Heading:** Section 300.220 Monitoring
- **Jurisdiction:** Illinois
- **Kind:** Regulations
- **Status:** In force
- **Text as of:** August 14, 2026
- **Source:** Compiled text
- **Location:** Illinois Administrative Code / Title 62 MINING / CHAPTER I: DEPARTMENT OF NATURAL RESOURCES / Part 300 SURFACE MINED LAND CONSERVATION AND RECLAMATION ACT / Section 300.220 Monitoring

## Text

Section 300
Section 300.220  Monitoring
a)         Duties of the Operator
1)         When the scaled distance has a value less than 65 at the
closest protected structure, the operator shall make a seismographic recording
and airblast recording at or as near as possible to that structure.
2)         When any blast is within 500 feet of a landfill, the operator
shall make a seismograph recording at or near the closest part of the landfill
to the blast.  This requirement shall not apply if a protected structure is
located between the blast and the landfill or if an alternative compliance
method has been approved by the Department in accordance with Section
300.225(f).
3)         When the cubed root scaled distance to the nearest protected
structure has a value less than 350 and when the burden to hole depth ratio is
greater than 1.0, or the top stemming height is less than 70% of the burden
dimension, the airblast produced by the blast shall be measured at or as near as
possible to the closest protected structure.
4)         When field programmed times of electronic, or programmable
detonators are unable to be electronically documented or verified in subsection
(a)(5)(a)(xiv), the operator shall make a seismographic and airblast recording
for Department review, at or as near as possible to the closest protected
structure.
5)         The operator shall maintain blasting records as follows:
A)        A record of each blast shall be made, retained by the operator
for at least five years and made available for inspection by the Department.
Each blast record, as well as other documentation deemed relevant to that
record, shall not be falsified or misrepresented.  Units of measure shall be
included on each blast record.  The blast record should be based on the maximum
pounds in any given hole in the blast.  Records of blasts conducted since the
Department's last inspection, or copies of such blasting records, shall be made
available at the operation for inspection by the Department
med relevant to that
record, shall not be falsified or misrepresented.  Units of measure shall be
included on each blast record.  The blast record should be based on the maximum
pounds in any given hole in the blast.  Records of blasts conducted since the
Department's last inspection, or copies of such blasting records, shall be made
available at the operation for inspection by the Department. The record is to
be completed by the end of the work day following the day in which the blast
occurred, including the seismograph meter reading, if required, and shall
contain the following data:
i)          Name of the mine operator for whom the blast is being
conducted.
ii)         The location, using global positioning data points, date and
time of the blast.
iii)        Name, signature and licensure number of the licensed blaster
responsible for the blast.
iv)        Type of material blasted.
v)         Number of holes, burden and spacing.
vi)        Diameter and depth of holes.
vii)       Type and amount of each explosive used, including any
variation from the heaviest hole.
viii)      Total weight of explosives used in pounds.
ix)        Maximum weight, in pounds, of explosives used in any one hole.
x)         Maximum weight of explosives, in pounds, detonated within any
eight millisecond period.
xi)        Maximum number of holes or explosive decks detonated within
any eight millisecond period.
xii)       Initiation system, including number of circuits and the timer
interval, if a sequential timer is used.
xiii)      Type and length of stemming (deck and top).
xiv)      Type of detonator and delay periods used, in milliseconds.  When
electronic or programmable detonators are used, field programmed times shall be
documented utilizing a date stamp which is derived from the machine used to
detonate the blast.  This documentation should be representative of the firing
times at the instant of detonation
i)      Type and length of stemming (deck and top).
xiv)      Type of detonator and delay periods used, in milliseconds.  When
electronic or programmable detonators are used, field programmed times shall be
documented utilizing a date stamp which is derived from the machine used to
detonate the blast.  This documentation should be representative of the firing
times at the instant of detonation.  This documentation is not required when
detonators are pre-programmed by the manufacturing facility with labels
indicating, in milliseconds, the nominal firing time.
xv)       Sketch of delay pattern, including decking, which indicates all
hole to hole connections and the firing times of each hole as well as a
directional indicator.
xvi)      Distance and scaled distance to the closest protected
structure, using global positioning data points.
xvii)     Location, using global positioning data points, of the closest
protected structure.
xviii)    Distance and scaled distance to the closest part of any
landfill within 500 feet of the blast.
xix)      A hole
diagram indicating borehole depth, subdrill, borehole diameter, type and length
of stemming, primer location, location and size of inert decks, weight and type
of explosives used per explosive column.
xx)       List
of persons assisting with blast loading and initiation.
xxi)      Drill
log showing the physical characteristics of each hole.
xxii)     Seismograph
recordings of airblast and ground vibration, when required.
xxiii)    Seismograph
identification number.
xxiv)    The
type of seismograph, sensitivity, and certification date of annual calibration
which must be conducted within one year of the previous calibration date.
B)        Air blast and/or ground vibration recordings, or photographic
copies thereof, where required by the Department, shall be kept for a period of
five years following the date of the blast, and shall be available for
inspection by the Department
seismograph, sensitivity, and certification date of annual calibration
which must be conducted within one year of the previous calibration date.
B)        Air blast and/or ground vibration recordings, or photographic
copies thereof, where required by the Department, shall be kept for a period of
five years following the date of the blast, and shall be available for
inspection by the Department. Records of blasts conducted since the
Department's last inspection, or copies of such blasting records, shall be made
available at the operation for inspection by the Department. The recordings
shall include the following information:
i)          Maximum airblast and/or ground vibration levels recorded.
ii)         The specific location of the monitoring equipment, its
distance from the blast and the date and time of the recording.
iii)        Name of the person and/or firm making the recording.
iv)        Name of the person and/or firm analyzing the recordings.
v)         The type of seismograph, sensitivity and certification date of
annual calibration which must be conducted within one year of the previous
calibration date.
C)        As used herein, "seismographic recording", or
"record of airblast recording", or "record" shall mean a
visually inspectable cartesian representation of the time history of the
particle velocity levels and/or airblast levels versus time.  The particle
velocity is shown by three traces representing mutually perpendicular components
of motion. The components are oriented vertically, transversely and
longitudinally to the horizontal direction from the recording location to the
location of the blast. The airblast time history is represented by a single
trace. The record or recording includes either an analog representation, or a
written description, of the vertical scale for the particle velocity traces and
the airblast trace. The units for the particle velocity traces and scale are in
inches per second
to the horizontal direction from the recording location to the
location of the blast. The airblast time history is represented by a single
trace. The record or recording includes either an analog representation, or a
written description, of the vertical scale for the particle velocity traces and
the airblast trace. The units for the particle velocity traces and scale are in
inches per second. The units for the airblast trace and scale are millibars,
pounds per square inch, or decibels. The recording shall also include an analog
or descriptive time scale. The time units are in seconds.
b)         Duties of the Department
1)         The Department shall conduct seismographic monitoring at any
operation at such times and conditions as the Department deems appropriate.
2)         The Department shall conduct inspections of the operation as
follows:
A)        Randomly without notice twice per year.
B)        At such other times and conditions as the Department deems
appropriate.
C)        Less frequently than twice per year at operations where
blasting is not regularly conducted.
3)         All Department employees conducting official business shall
inform the operator or the operator's designated representative, if either is
present, upon arrival to and departure from the operation.

## Nearby sections

- [62 Ill. Adm. Code 300.200 Section 300.200  Scope of this Subpart](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P300_S300_200.md)
- [62 Ill. Adm. Code 300.205 Section 300.205  Purpose](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P300_S300_205.md)
- [62 Ill. Adm. Code 300.210 Section 300.210  Definitions Applicable to Subpart B](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P300_S300_210.md)
- [62 Ill. Adm. Code 300.215 Section 300.215  General Requirements](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P300_S300_215.md)
- [62 Ill. Adm. Code 300.220 Section 300.220  Monitoring](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P300_S300_220.md)
- [62 Ill. Adm. Code 300.225 Section 300.225  Use of Explosives; Control of Adverse Effects](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P300_S300_225.md)
- [62 Ill. Adm. Code 300.230 Section 300.230  Use of Explosives; Blasting Signs, Warnings, and Access Control](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P300_S300_230.md)
- [62 Ill. Adm. Code 300.235 Section 300.235  Training](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P300_S300_235.md)
- [62 Ill. Adm. Code 300.236 Section 300.236  Examination](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P300_S300_236.md)
- [62 Ill. Adm. Code 300.237 Section 300.237  Application and Licensure](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P300_S300_237.md)
- [62 Ill. Adm. Code 300.238 Section 300.238  Fees](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P300_S300_238.md)
- [62 Ill. Adm. Code 300.239 Section 300.239  Denial, Issuance of Notice of Infraction, Suspension, Revocation and Other Administrative Actions](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P300_S300_239.md)
- [62 Ill. Adm. Code 300.245 Section 300.245  Notices of Violation](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P300_S300_245.md)
- [62 Ill. Adm. Code 300.246 Section 300.246  Cessation Orders](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P300_S300_246.md)

---

Source: Frix Law Library, https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P300_S300_220. Check the current official text before relying on it. Not legal advice.