# 62 Ill. Adm. Code 220.50: Section 220.50 Electrical Equipment-General

> Illinois · Regulations · In force

URL: https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P220_S220_50

## Section

- **Citation:** 62 Ill. Adm. Code 220.50
- **Heading:** Section 220.50 Electrical Equipment-General
- **Jurisdiction:** Illinois
- **Kind:** Regulations
- **Status:** In force
- **Text as of:** August 14, 2026
- **Source:** Compiled text
- **Location:** Illinois Administrative Code / Title 62 MINING / CHAPTER I: DEPARTMENT OF NATURAL RESOURCES / Part 220 SURFACE INSTALLATION HEALTH AND SAFETY / Section 220.50 Electrical Equipment-General

## Text

Section 220
Section 220.50  Electrical
Equipment-General
a)         Electric power circuits and electric equipment;
deenergization.
Power circuits and electric equipment shall be deenergized
before work is done on such circuits or equipment, except when necessary for
trouble-shooting or testing.  Disconnecting devices shall be locked out and
suitably tagged by the persons who perform such work, except that in cases
where locking out is not possible, such devices shall be opened and suitably
tagged by such persons.  Locks and tags shall be removed only by the persons
who installed them, or, if such persons are unavailable, by persons authorized
by the operator or his agent.
b)         Electric circuits and equipment; repair.
No electrical work shall be performed on electric circuits or
equipment except by a person qualified to perform electrical work and to
maintain electrical equipment, or by a person trained to perform electrical
work and to maintain electrical equipment at the direction of a qualified
person. When such work is done by a trained person, the circuits or equipment
shall be examined by a qualified person to assure safe operating condition
before such circuits or equipment are energized.
c)         Electric equipment; examination, testing, and maintenance.
Electric equipment shall be frequently examined, tested and
properly maintained by a person qualified to perform electrical work and to
maintain electrical equipment to assure safe operating conditions.  When a
potentially dangerous condition is found on electric equipment, such equipment
shall be identified and be removed from service until such condition is
corrected.  A record of such examinations shall be kept in an approved book, and
shall include all dangerous conditions found, corrective actions taken, and the
signature of the qualified person conducting the examination or testing
ns.  When a
potentially dangerous condition is found on electric equipment, such equipment
shall be identified and be removed from service until such condition is
corrected.  A record of such examinations shall be kept in an approved book, and
shall include all dangerous conditions found, corrective actions taken, and the
signature of the qualified person conducting the examination or testing.  The
record of examinations shall be signed by the person responsible for
maintaining the equipment in safe operating condition, who shall also be a
person qualified to perform electrical work and maintain electrical equipment,
and records shall be made available for inspection by an authorized
representative of the Department and the authorized representative of miners of
such mine.
d)         Electric equipment; examination and testing.
A potentially dangerous condition within the meaning of
Section 220.50(c) shall include without limitation, exposed conductors,
improper frame grounding, missing guards, missing inspection covers,
poorly-made splices in conductors, improper terminations, improper overload or
short circuit protection, broken conduit, missing or malfunctioning safety
devices, inoperative indicating lights, inoperative ground fault protection, defective
monitoring circuits, and inadequate ground fields.
e)         Qualified person.
A qualified person within the meaning of Sections 220.50(b),
220.50(c), 220.60(b), 220.80(b) and Section 220.90 of this Part is an
individual who has been qualified as a coal miner electrician under 30 CFR
77.103, or anyone who may be so qualified in the future as a coal miner
electrician by the Department, if and when such Department adopts rules
affecting coal miner electrician certification.
f)         Electric equipment; frequency of examination and testing
), 220.60(b), 220.80(b) and Section 220.90 of this Part is an
individual who has been qualified as a coal miner electrician under 30 CFR
77.103, or anyone who may be so qualified in the future as a coal miner
electrician by the Department, if and when such Department adopts rules
affecting coal miner electrician certification.
f)         Electric equipment; frequency of examination and testing.
The examinations and test required under the provisions of
Section 220.50(c) shall be conducted as interpreted in the Mining Enforcement
Safety Administration (MESA) Inspector's Manual at least monthly or more often
if necessary to assure safe operating conditions.  State Mine Inspectors shall
be presented evidence of qualifications upon request.
g)         Electric conductors; capacity and insulation.
Electric conductors shall be sufficient in size and have
adequate current-carrying capacity and be of such construction that a rise in
temperature resulting from normal operation will not damage the insulating
materials.
h)         Electric Conductors.
Electric conductors, installed inside surface buildings and
structures, shall be sufficient in size to meet the minimum current-carrying
capacity provided for in the National Electrical Code in effect at the time of
installation.
i)          Electric conductors; mobile and portable equipment.
Trailing cable, portable cables, and electric conductors
installed in mobile or portable equipment shall have ampacities and
construction in accordance with the specifications of Insulated Power Cable
Engineers Association-National Electrical Manufacturers Association in effect
at time of purchase and the conductors shall be sufficient in size so that a
rise in temperature resulting from normal operation will not damage the
insulating material.
j)          Electrical connections or splices; suitability
pacities and
construction in accordance with the specifications of Insulated Power Cable
Engineers Association-National Electrical Manufacturers Association in effect
at time of purchase and the conductors shall be sufficient in size so that a
rise in temperature resulting from normal operation will not damage the
insulating material.
j)          Electrical connections or splices; suitability.
Electrical connections or splices in electric conductors
shall be mechanically and electrically efficient, and suitable connectors or
approved splicing methods shall be used.  All electrical connections or splices
in insulated wire and cable shall be reinsulated at least to the same degree of
protection as the remainder of the wire or cable.
k)         Cable fittings; suitability.
Cables shall enter metal frames of motors, splice boxes, and
electric compartments only through proper fittings and shall be secured to prevent
chaffing of the insulation.  When insulated wires, other than wiring installed
in conduit, pass through metal frames, the holes shall be substantially bushed
with insulated bushings and the wires be secured.
l)          Electric equipment and circuits; overload, short-circuit, and
ground fault protection.
Automatic circuit-breaking devices or fuses of the correct
type and capacity shall be installed so as to protect all electric equipment
and circuits against short circuit and overloads.  Ground fault protection
shall be provided for equipment, powered by solidly or resistance grounds'
systems.
m)        Electric equipment and circuits; overload and short-circuit
protection; minimum requirements
tomatic circuit-breaking devices or fuses of the correct
type and capacity shall be installed so as to protect all electric equipment
and circuits against short circuit and overloads.  Ground fault protection
shall be provided for equipment, powered by solidly or resistance grounds'
systems.
m)        Electric equipment and circuits; overload and short-circuit
protection; minimum requirements.
Devices providing short-circuits and overload protection
shall conform to the minimum requirements for protection of electric circuits
and equipment of the National Electrical Code in effect at the time of
installation except that motors and circuits used in specially designed
electrical systems, such as those used on some excavators, hoists and
elevators, shall be considered as being provided with overload protection if
the design of the system prevents the motors and associated circuits from being
subjected to harmful overloads.
n)         Electric equipment-switches.
All electric equipment contracted for after the effective
date of this regulation shall be provided with switches or other controls that
are safely designed, constructed, and installed.  The voltage of alternating
current remote control circuits that are installed external to the controller
enclosure shall not exceed one hundred twenty (120) volt.
o)         Lightning arresters; ungrounded, exposed power conductors, and
telephone wires.
All ungrounded, exposed power conductors, control lines, and
communication wires shall be equipped with suitable lightning arresters which
are adequately installed and connected to a low resistance grounding medium in
accordance with Section 220.70(f).
p)         Lightning arresters; circuits entering or leaving buildings.
Lightning arresters protecting circuits entering or leaving
buildings shall be provided at a point near where each such circuit enters or
leaves the building.
q)         Transformers and high-voltage equipment; installation and
guarding; minimum vertical clearance
ance grounding medium in
accordance with Section 220.70(f).
p)         Lightning arresters; circuits entering or leaving buildings.
Lightning arresters protecting circuits entering or leaving
buildings shall be provided at a point near where each such circuit enters or
leaves the building.
q)         Transformers and high-voltage equipment; installation and
guarding; minimum vertical clearance.
1)         Transformers and other high-voltage equipment shall be of the
enclosed type, or installed in a transformer house, or surrounded by a
substantial fence at least six (6) feet high and at least three (3) feet from
any energized parts, casings, or wiring.
2)         Enclosures of high-voltage equipment shall be kept locked
against unauthorized entry.
3)         Electric equipment energized at more than one thousand (1,000)
volts and containing unguarded live parts, shall be installed with a minimum
vertical clearance above the surfaces where a person would normally stand, as
follows:
Voltage
Between Phases
Minimum
Vertical Clearance of Unguarded Parts:
Feet
Inches
1,000
– 6,600
8
0
6,601
– 11,000
9
0
11,001
– 22,000
9
3
22,001
– 33,000
9
6
33,001
– 44,000
9
10
44,001
– 66,000
10
5
66,001
– 88,000
11
0
88,001
– 110,000
11
7
110,001
– 132,000
12
2
r)          Resistors; location and guarding.
Resistors, heaters, and rheostats shall be located so as to
minimize fire hazards and, where necessary, provided with guards to prevent
personal contact.
s)         Danger signs at high-voltage electrical installations.
Danger signs shall be posted at the entrance to all
high-voltage electrical installations.
t)          Inspection and cover plates.
Inspection and cover plates on electrical equipment shall be
kept in place at all times except during testing or repairs.  Equipment
designed with exposed energized parts shall be properly guarded to prevent
accidental contact.
u)         Insulated platforms at power switches
shall be posted at the entrance to all
high-voltage electrical installations.
t)          Inspection and cover plates.
Inspection and cover plates on electrical equipment shall be
kept in place at all times except during testing or repairs.  Equipment
designed with exposed energized parts shall be properly guarded to prevent
accidental contact.
u)         Insulated platforms at power switches.
Insulated mats or platforms, insulated for the phase-to-phase
voltage of the system, shall be kept in place at all switchboards and power
control switches where shock hazards exist.  However, metal plates on which a
person normally would stand and which are kept at the same potential as the
grounded, metal noncurrent-carrying parts of the power switches to be operated,
may be used.
v)         Switchboards; enclosures, passageways, and clearance.
Switchboards in stationary installations which require back
access shall be provided with passageways or lanes of travel which permit
access to the back of the switchboard from both ends for inspection,
adjustment, or repair.  Openings permitting access to the rear of any
switchboard shall be guarded, except where they are located in buildings which
are kept locked. Enclosures containing switchboards motor generators sets,
transformers, oil circuit breakers, and resistance panels shall not be used for
the storage of material.
w)        Bare signal or control wires; voltage.
The voltage on bare signal or control wires accessible to
personal contact shall not exceed forty (40) volts.
x)         Electric Wiring and equipment; Installation and maintenance.
Except as otherwise provided in this Part, all wiring and
electrical equipment installed after effective date of this regulation shall
meet the requirements of the National Electric Code in effect at the time of
installation.
y)         Hazardous locations, surface facilities; bituminous and
lignite mines
forty (40) volts.
x)         Electric Wiring and equipment; Installation and maintenance.
Except as otherwise provided in this Part, all wiring and
electrical equipment installed after effective date of this regulation shall
meet the requirements of the National Electric Code in effect at the time of
installation.
y)         Hazardous locations, surface facilities; bituminous and
lignite mines.
1)         All electrical circuits and equipment installed after
effective date of this regulation with a coal preparation plant or other
enclosure housing coal-handling facilities, except in sections where only wet
coal is handled or in sections so maintained as to be free from dangerous amounts
of coal dust, shall be of the type designed for hazardous locations, Class II,
Group F, and installed in accordance with the requirements in Article 501 of
the National Electrical Code.
2)         Enclosed areas where methane may accumulate and is not prevented
from accumulating by an adequate ventilation system shall have electric
circuits and equipment of the type designed for hazardous locations, Class I,
Group D, and installed in accordance with the requirements in Article 501 of
the National Electrical Code.
3)         An adequate ventilation system within the meaning of paragraph
(b) above is a system in which:
A)        The enclosed area is monitored continuously in accordance with
the provisions of Section 220.20(n); and
B)        The provisions of Section 220.20(a) are complied with.
z)         Approved permissible equipment.
Permissible electrical equipment which is maintained in a
permissible condition may be used in lieu of equipment required in Section
220.50(y).
aa)       Minimum wiring requirements for stationary structures and
buildings; general
accordance with
the provisions of Section 220.20(n); and
B)        The provisions of Section 220.20(a) are complied with.
z)         Approved permissible equipment.
Permissible electrical equipment which is maintained in a
permissible condition may be used in lieu of equipment required in Section
220.50(y).
aa)       Minimum wiring requirements for stationary structures and
buildings; general.
1)         All wiring shall be installed so as to be adequately protected
from physical damage;
2)         Raceways, cable assemblies, boxes, cabinets, and fittings
shall be securely fastened in place;
3)         Cables, conductors, metal raceways, cable armor, boxes,
fittings, supports, and other wiring hardware shall be of proper construction
and material for the environment in which they are installed;
4)         Power cables within surface structures shall closely follow
the surface of the building or the other continuous support and shall be
secured at intervals not exceeding four and one-half (4 1/2) feet and within
one (1) foot from every box fitting; and
5)         All open conductors within surface structures shall closely
follow the surface of the building and be installed on proper insulators which
support the wires at least every four and one-half (4 1/2) feet.
bb)       Equipment marking.
All electrical equipment purchased or rebuilt after the
effective date of these rules shall be provided with a plate which indicates
the manufacturer's name, rated voltage, current, horsepower, frequency, number
of phases, and duty cycle.
cc)       Protection of power cables.
All power cables and wiring shall be adequately protected
against mechanical damage.  If a cable is damaged to the extent that the outer
jacket will not exclude moisture, or if the conductors or metallic shielding
are exposed, the cable jacket shall be repaired to the same degree of
protection as the remainder of the cable.
dd)      Identification
y cycle.
cc)       Protection of power cables.
All power cables and wiring shall be adequately protected
against mechanical damage.  If a cable is damaged to the extent that the outer
jacket will not exclude moisture, or if the conductors or metallic shielding
are exposed, the cable jacket shall be repaired to the same degree of
protection as the remainder of the cable.
dd)      Identification.
Circuit breakers, disconnects, control switches, and push
buttons shall be marked to show which circuit they control, unless
identification can be made readily by location.

## Nearby sections

- [62 Ill. Adm. Code 220.10 Section 220.10  Introduction and Definitions](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P220_S220_10.md)
- [62 Ill. Adm. Code 220.20 Section 220.20  Surface Installations](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P220_S220_20.md)
- [62 Ill. Adm. Code 220.30 Section 220.30  Thermal Dryers](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P220_S220_30.md)
- [62 Ill. Adm. Code 220.40 Section 220.40  Safeguard For Mechanical Equipment](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P220_S220_40.md)
- [62 Ill. Adm. Code 220.50 Section 220.50  Electrical Equipment-General](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P220_S220_50.md)
- [62 Ill. Adm. Code 220.60 Section 220.60  Trailing Cables](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P220_S220_60.md)
- [62 Ill. Adm. Code 220.70 Section 220.70  Grounding](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P220_S220_70.md)
- [62 Ill. Adm. Code 220.80 Section 220.80  Surface High-Voltage Distribution](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P220_S220_80.md)
- [62 Ill. Adm. Code 220.90 Section 220.90  Low and Medium-Voltage Alternating Current Circuits](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P220_S220_90.md)
- [62 Ill. Adm. Code 220.100 Section 220.100  Ground Control](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P220_S220_100.md)
- [62 Ill. Adm. Code 220.110 Section 220.110  Fire Protection](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P220_S220_110.md)
- [62 Ill. Adm. Code 220.120 Section 220.120  Mine Maps](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P220_S220_120.md)
- [62 Ill. Adm. Code 220.130 Section 220.130  Explosives and Blasting](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P220_S220_130.md)
- [62 Ill. Adm. Code 220.140 Section 220.140  Man Hoisting](https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P220_S220_140.md)

---

Source: Frix Law Library, https://www.frixlaw.com/law-library/statutes/STATE_IL_IAC_T62_P220_S220_50. Check the current official text before relying on it. Not legal advice.