# 6 CCR 1007-1 Part 04: RADIATION CONTROL - STANDARDS FOR PROTECTION AGAINST RADIATION

> Colorado · Regulations · In force

URL: https://www.frixlaw.com/law-library/statutes/STATE_CO_CCR_6_CCR_1007_1_Part_04

## Section

- **Citation:** 6 CCR 1007-1 Part 04
- **Heading:** RADIATION CONTROL - STANDARDS FOR PROTECTION AGAINST RADIATION
- **Jurisdiction:** Colorado
- **Kind:** Regulations
- **Status:** In force
- **Text as of:** September 30, 2026
- **Source:** Compiled text
- **Location:** Code of Colorado Regulations / 1000 Department of Public Health and Environment / 1007 Hazardous Materials and Waste Management Division / 6 CCR 1007-1 Part 04

## Text

_________________________________________________________________________
Adopted by the Board of Health on October 18, 2023; effective December 15, 2023.
PART 4:
STANDARDS FOR PROTECTION AGAINST RADIATION
STANDARDS FOR PROTECTION AGAINST RADIATION
4.1
Purpose and Scope
4.1.1
Authority.
4.1.1.1 Rules and regulations set forth herein are adopted pursuant to the provisions of Sections
25-1-108, 25-1.5-101(1)(k) and (1)(l), and 25-11-104, CRS.
4.1.2
Basis and Purpose.
4.1.2.1 A statement of basis and purpose of these regulations is incorporated as part of these
regulations; a copy may be obtained from the Department.
4.1.3
Scope.
4.1.3.1 This Part 4 establishes standards for protection against ionizing radiation resulting from
activities conducted pursuant to licenses or registrations issued by the Department.
4.1.3.2 The requirements of Part 4 are designed to control the receipt, possession, use, transfer,
and disposal of sources of radiation by any licensee or registrant so the total dose to an
individual, including doses resulting from all sources of radiation other than background
radiation, does not exceed the standards for protection against radiation prescribed in
Part 4. However, nothing in Part 4 shall be construed as limiting actions that may be
necessary to protect health and safety.
4.1.4
Applicability.
4.1.4.1 Except as specifically provided in other parts of these regulations, Part 4 applies to
persons licensed or registered by the Department to receive, possess, use, transfer, or
dispose of sources of radiation. The limits in Part 4 do not apply to doses due to
background radiation, to exposure of patients to radiation for the purpose of medical
diagnosis or therapy, to exposure from individuals administered radioactive material and
released in accordance with 7.26, or to exposure from voluntary participation in medical
research programs.
Hazardous Materials and Waste Management
2
4.1.5
Published Material Incorporated by Reference.
4.1.5.1 Throughout this Part 4, federal regulations, state regulations, and standards or guidelines
of outside organizations have been adopted and incorporated by reference. Unless a
prior version of the incorporated material is otherwise specifically indicated, the materials
incorporated by reference cited herein include only those versions that were in effect as
of the most recent effective date of this Part 4 (December 2023), and not later
amendments or editions of the incorporated material.
4.1.5.2 Materials incorporated by reference are available for public inspection, and copies
(including certified copies) can be obtained at reasonable cost, during normal business
hours from the Colorado Department of Public Health and Environment, Hazardous
Materials and Waste Management Division, 4300 Cherry Creek Drive South, Denver,
Colorado 80246. Additionally, https://www.colorado.gov/hm/radregs identifies where the
incorporated material is available to the public on the internet at no cost. Due to copyright
restrictions, certain materials incorporated in this Part are available for public inspection
at the state publications depository and distribution center.
4.1.5.3 Availability from Source Agencies or Organizations.
(1)
All federal agency regulations incorporated by reference herein are available at
no cost in the online edition of the Code of Federal Regulations (CFR) hosted by
the U.S. Government Publishing Office, online at
https://www.govinfo.gov/app/collection/cfr/.
(2)
All state regulations incorporated by reference herein are available at no cost in
the online edition of the Code of Colorado Regulations (CCR) hosted by the
Colorado Secretary of State’s Office, online at
https://www.sos.state.co.us/CCR/Welcome.do.
4.2
Definitions.
4.2.1
Reserved.
4.3
Implementation.
4.3.1
Any existing license or registration condition that is more restrictive than Part 4 remains in
force until there is an amendment or renewal of the license or registration.
4.4
Reserved.
RADIATION PROTECTION PROGRAMS
4.5
Radiation Protection Programs.
4.5.1
Each licensee or registrant shall develop, document, and implement a radiation protection
program sufficient to ensure compliance with the provisions of Part 4. See 4.41 for recordkeeping
requirements relating to these programs.
4.5.2
The licensee or registrant shall use, to the extent practical, procedures and engineering controls
based upon sound radiation protection principles to achieve occupational doses and doses to
members of the public that are as low as is reasonably achievable (ALARA).
4.5.3
The licensee or registrant shall, at intervals not to exceed 12 months, review the radiation
protection program content and implementation.
Hazardous Materials and Waste Management
3
4.5.4
To implement the ALARA requirements of 4.5.2 and notwithstanding the requirements in 4.14 of
this part, a constraint on air emissions of radioactive material to the environment, excluding
radon-222 and its decay products, shall be established by licensees, such that the individual
member of the public likely to receive the highest dose will not be expected to receive a total
effective dose equivalent in excess of 0.1 millisievert (10 mrem) per year from these emissions. If
a licensee subject to this requirement exceeds this dose constraint, the licensee shall report such
event as provided in 4.53.2 and promptly take appropriate corrective action to ensure against
recurrence.
OCCUPATIONAL DOSE LIMITS
4.6
Occupational Dose Limits for Adults.
4.6.1
The licensee or registrant shall control the occupational dose to individual adults, except for
planned special exposures pursuant to 4.11, to the following dose limits:
4.6.1.1 An annual limit, which is the more limiting of:
(1)
The total effective dose equivalent being equal to 0.05 Sv (5 rem); or
(2)
The sum of the deep dose equivalent and the committed dose equivalent to any
individual organ or tissue other than the lens of the eye being equal to 0.5 Sv (50
rem).
4.6.1.2 The annual limits to the lens of the eye, to the skin of the whole body, and to the skin of
the extremities, which are:
(1)
A lens dose equivalent of 0.15 Sv (15 rem), and
(2)
A shallow dose equivalent of 0.5 Sv (50 rem) to the skin of the whole body or to
the skin of any extremity.
4.6.2
Doses received in excess of the annual limits, including doses received during accidents,
emergencies, and planned special exposures, shall be subtracted from the limits for planned
special exposures that the individual may receive during the current year and during the
individual's lifetime. See 4.11.5.1 and 4.11.5.2.
4.6.3
Assigned dose equivalent.
4.6.3.1 When the external exposure is determined by measurement with an external personal
monitoring device, the deep-dose equivalent must be used in place of the effective dose
equivalent, unless the effective dose equivalent is determined by a dosimetry method
approved by the NRC.
4.6.3.2 The assigned deep dose equivalent must be for the part of the body receiving the highest
exposure.
4.6.3.3 The assigned shallow dose equivalent must be the dose averaged over the contiguous
10 square centimeters of skin receiving the highest exposure.
4.6.3.4 The deep-dose equivalent, lens dose equivalent, and shallow dose equivalent may be
assessed from surveys or other radiation measurements for the purpose of
demonstrating compliance with the occupational dose limits, if the individual monitoring
device was not in the region of highest potential exposure, or the results of individual
monitoring are unavailable.
Hazardous Materials and Waste Management
4
4.6.3.5 In the case of occupational exposures to x-rays with accelerating voltages of less than
145 kVp and where the worker utilizes lead garment protection, the registrant may
calculate the assigned dose equivalent using methods discussed in NRC Regulatory
Information Summary (RIS) 2002-061, other methods as specifically approved by the
Department, or by use of the following equation:
1 NRC RIS 2002-06, Evaluating Occupational Dose For Individuals Exposed To NRC-licensed Material And Medical X-Rays, April
16, 2002 (http://www.nrc.gov/; ML021000613).
(1)
Lead apron and no thyroid collar:
assigned deep dose equivalent = 0.06 x (collar dose – waist dose) + waist dose
(2)
Lead apron and thyroid collar:
assigned deep dose equivalent = 0.02 x (collar dose – waist dose) + waist dose
4.6.4
Derived air concentration (DAC) and annual limit on intake (ALI) values are presented in Table
4B1 of Appendix 4B and may be used to determine the individual's dose and to demonstrate
compliance with the occupational dose limits. See 4.46.
4.6.5
Notwithstanding the annual dose limits, the licensee shall limit the soluble uranium intake by an
individual to 10 milligrams in a week in consideration of chemical toxicity. See footnote 3 of
Appendix 4B.
4.6.6
The licensee or registrant shall reduce the dose that an individual may be allowed to receive in
the current year by the amount of occupational dose received while employed by any other
person. See 4.10.3.1 and 4.10.5.
4.7
Compliance with Requirements for Summation of External and Internal Doses.
4.7.1
If the licensee or registrant is required to monitor pursuant to both 4.18.1 and 4.18.2, the licensee
or registrant shall demonstrate compliance with the dose limits by summing external and internal
doses. If the licensee or registrant is required to monitor only pursuant to 4.18.1 or only pursuant
to 4.18.2, then summation is not required to demonstrate compliance with the dose limits. The
licensee or registrant may demonstrate compliance with the requirements for summation of
external and internal doses pursuant to 4.7.2, 4.7.3 and 4.7.4. The dose equivalents for the lens
of the eye, the skin, and the extremities are not included in the summation, but are subject to
separate limits.
4.7.2
Intake by Inhalation.
If the only intake of radionuclides is by inhalation, the total effective dose equivalent limit is not
exceeded if the sum of the deep dose equivalent divided by the total effective dose equivalent
limit, and one of the following, does not exceed unity:
4.7.2.1 The sum of the fractions of the inhalation ALI for each radionuclide, or
4.7.2.2 The total number of derived air concentration-hours (DAC-hours) for all radionuclides
divided by 2,000, or
Hazardous Materials and Waste Management
5
4.7.2.3 The sum of the calculated committed effective dose equivalents to all significantly
irradiated organs or tissues (T) calculated from bioassay data using appropriate biological
models and expressed as a fraction of the annual limit. For purposes of this requirement,
an organ or tissue is deemed to be significantly irradiated if, for that organ or tissue, the
product of the weighting factors, WT, and the committed dose equivalent, HT, 50, per unit
intake is greater than 10 percent of the maximum weighted value of H50, that is, WT x HT,
50, per unit intake for any organ or tissue.
4.7.3
Intake by Oral Ingestion.
4.7.3.1 If the occupationally exposed individual also receives an intake of radionuclides by oral
ingestion greater than 10 percent of the applicable oral ALI, the licensee or registrant
shall account for this intake and include it in demonstrating compliance with the limits.
4.7.4
Intake through Wounds or Absorption through Skin.
4.7.4.1 The licensee or registrant shall evaluate and, to the extent practical, account for intakes
through wounds or skin absorption. The intake through intact skin has been included in
the calculation of DAC for hydrogen-3 and does not need to be evaluated or accounted
for pursuant to 4.7.4.
4.8
Determination of External Dose from Airborne Radioactive Material.
4.8.1
Licensees or registrants shall, when determining the dose from airborne radioactive material,
include the contribution to the deep dose equivalent, lens dose equivalent, and shallow dose
equivalent from external exposure to the radioactive cloud. See Appendix 4B, footnotes 1 and 2.
4.8.2
Airborne radioactivity measurements and DAC values shall not be used as the primary means to
assess the deep dose equivalent when the airborne radioactive material includes radionuclides
other than noble gases or if the cloud of airborne radioactive material is not relatively uniform.
The determination of the deep dose equivalent to an individual shall be based upon
measurements using instruments or individual monitoring devices.
4.9
Determination of Internal Exposure.
4.9.1
For purposes of assessing dose used to determine compliance with occupational dose equivalent
limits, the licensee or registrant shall, when required pursuant to 4.18, take suitable and timely
measurements of:
4.9.1.1 Concentrations of radioactive materials in air in work areas; or
4.9.1.2 Quantities of radionuclides in the body; or
4.9.1.3 Quantities of radionuclides excreted from the body; or
4.9.1.4 Combinations of 4.9.1.1, 4.9.1.2 and 4.9.1.3.
4.9.2
Unless respiratory protective equipment is used, as provided in 4.24, or the assessment of intake
is based on bioassays, the licensee or registrant shall assume that an individual inhales
radioactive material at the airborne concentration in which the individual is present.
4.9.3
When specific information on the physical and biochemical properties of the radionuclides taken
into the body or the behavior of the material in an individual is known, the licensee or registrant
may:
Hazardous Materials and Waste Management
6
4.9.3.1 Use that information to calculate the committed effective dose equivalent, and, if used,
the licensee or registrant shall document that information in the individual's record; and
4.9.3.2 Upon prior approval of the Department, adjust the DAC or ALI values to reflect the actual
physical and chemical characteristics of airborne radioactive material, for example,
aerosol size distribution or density; and
4.9.3.3 Separately assess the contribution of fractional intakes of Class D, W, or Y compounds of
a given radionuclide to the committed effective dose equivalent. See Appendix 4B.
4.9.4
If the licensee or registrant chooses to assess intakes of Class Y material using the
measurements given in 4.9.1.2 or 4.9.1.3, the licensee or registrant may delay the recording and
reporting of the assessments for periods up to 7 months, unless otherwise required by 4.52 or
4.53. This delay permits the licensee or registrant to make additional measurements basic to the
assessments.
4.9.5
If the identity and concentration of each radionuclide in a mixture are known, the fraction of the
DAC applicable to the mixture for use in calculating DAC-hours shall be either:
4.9.5.1 The sum of the ratios of the concentration to the appropriate DAC value, that is, D, W, or
Y, from Appendix 4B for each radionuclide in the mixture; or
4.9.5.2 The ratio of the total concentration for all radionuclides in the mixture to the most
restrictive DAC value for any radionuclide in the mixture.
4.9.6
If the identity of each radionuclide in a mixture is known, but the concentration of one or more of
the radionuclides in the mixture is not known, the DAC for the mixture shall be the most restrictive
DAC of any radionuclide in the mixture.
4.9.7
When a mixture of radionuclides in air exists, a licensee or registrant may disregard certain
radionuclides in the mixture if:
4.9.7.1 The licensee or registrant uses the total activity of the mixture in demonstrating
compliance with the dose limits in 4.6 and in complying with the monitoring requirements
in 4.18.2; and
4.9.7.2 The concentration of any radionuclide disregarded is less than 10 percent of its DAC; and
4.9.7.3 The sum of these percentages for all of the radionuclides disregarded in the mixture does
not exceed 30 percent.
4.9.8
When determining the committed effective dose equivalent, the following information may be
considered:
4.9.8.1 In order to calculate the committed effective dose equivalent, the licensee or registrant
may assume that the inhalation of one ALI, or an exposure of 2,000 DAC-hours, results in
a committed effective dose equivalent of 0.05 Sv (5 rem) for radionuclides that have their
ALIs or DACs based on the committed effective dose equivalent.
Hazardous Materials and Waste Management
7
4.9.8.2 For an ALI and the associated DAC determined by the nonstochastic organ dose limit of
0.5 Sv (50 rem), the intake of radionuclides that would result in a committed effective
dose equivalent of 0.05 Sv (5 rem), that is, the stochastic ALI, is listed in parentheses in
Table 4B1 of Appendix 4B. The licensee or registrant may, as a simplifying assumption,
use the stochastic ALI to determine committed effective dose equivalent. However, if the
licensee or registrant uses the stochastic ALI, the licensee or registrant shall also
demonstrate that the limit in 4.6.1.1.(2) is met.
4.10
Determination of Prior Occupational Dose.
4.10.1 For each individual who is likely to receive, in a year, an occupational dose requiring monitoring
pursuant to 4.18, the licensee or registrant shall determine the occupational radiation dose
received during the current year.
4.10.2 Prior to permitting an individual to participate in a planned special exposure, the licensee or
registrant shall determine:
4.10.2.1
The internal and external doses from all previous planned special exposures; and
4.10.2.2
All doses in excess of the limits, including doses received during accidents and
emergencies, received during the lifetime of the individual.
4.10.3 In complying with the requirements of 4.10.1 or 4.10.2, a licensee or registrant may:
4.10.3.1
Accept, as a record of the occupational dose that the individual received during
the current year, a written signed statement from the individual, or from the individual's
most recent employer for work involving radiation exposure, that discloses the nature and
the amount of any occupational dose that the individual received during the current year;
and
4.10.3.2
Accept, as the record of cumulative radiation dose, an up-to-date Department
Form R-16, Cumulative Occupational Exposure History, or equivalent, signed by the
individual and countersigned by an appropriate official of the most recent employer for
work involving radiation exposure, or the individual's current employer, if the individual is
not employed by the licensee or registrant; and
4.10.3.3
Obtain reports of the individual's dose equivalent from the most recent employer
for work involving radiation exposure, or the individual's current employer, if the individual
is not employed by the licensee or registrant, by telephone, telegram, facsimile, or letter.
The licensee or registrant shall request a written verification of the dose data if the
authenticity of the transmitted report cannot be established.
4.10.4 Record of Exposure History.
4.10.4.1
The licensee or registrant shall record the exposure history, as required by 4.10.1
or 4.10.2, on Department Form R-16, or other clear and legible record, of all the
information required on that form. The form or record shall show each period in which the
individual received occupational exposure to radiation or radioactive material and shall be
signed by the individual who received the exposure. For each period for which the
licensee or registrant obtains reports, the licensee or registrant shall use the dose shown
in the report in preparing Department Form R-16 or equivalent. For any period in which
the licensee or registrant does not obtain a report, the licensee or registrant shall place a
notation on Department Form R-16 or equivalent indicating the periods of time for which
data are not available.
Hazardous Materials and Waste Management
8
4.10.4.2
Licensees or registrants are not required to reevaluate the separate external
dose equivalents and internal committed dose equivalents or intakes of radionuclides
assessed pursuant to the Regulations in Part 4 in effect before January 1, 1994. Further,
occupational exposure histories obtained and recorded before January 1, 1994 on
Department Form R-16 or equivalent, would not have included effective dose equivalent,
but may be used in the absence of specific information on the intake of radionuclides by
the individual.
4.10.5 If the licensee or registrant is unable to obtain a complete record of an individual's current and
previously accumulated occupational dose, the licensee or registrant shall assume:
4.10.5.1
In establishing administrative controls pursuant to 4.6.6 for the current year, that
the allowable dose limit for the individual is reduced by 12.5 mSv (1.25 rem) for each
quarter for which records were unavailable and the individual was engaged in activities
that could have resulted in occupational radiation exposure; and
4.10.5.2
That the individual is not available for planned special exposures.
4.10.6 The licensee or registrant shall retain the records on Department Form R-16 or equivalent until
the Department terminates each pertinent license or registration requiring this record. The
licensee or registrant shall retain records used in preparing Department Form R-16 or equivalent
for 3 years after the record is made.
4.11
Planned Special Exposures.
A licensee or registrant may authorize an adult worker to receive doses in addition to and
accounted for separately from the doses received under the limits specified in 4.6 provided that
each of the following conditions in 4.11.1 through 4.11.7 is satisfied:
4.11.1 The licensee or registrant authorizes a planned special exposure only in an exceptional situation
when alternatives that might avoid the dose estimated to result from the planned special
exposure are unavailable or impractical.
4.11.2 The licensee or registrant, and employer if the employer is not the licensee or registrant,
specifically authorizes the planned special exposure, in writing, before the exposure occurs.
4.11.3 Before a planned special exposure, the licensee or registrant ensures that each individual
involved is:
4.11.3.1
Informed of the purpose of the planned operation; and
4.11.3.2
Informed of the estimated doses and associated potential risks and specific
radiation levels or other conditions that might be involved in performing the task; and
4.11.3.3
Instructed in the measures to be taken to keep the dose ALARA considering
other risks that may be present.
4.11.4 Prior to permitting an individual to participate in a planned special exposure, the licensee or
registrant ascertains prior doses as required by 4.10.2 during the lifetime of the individual for each
individual involved.
4.11.5 Subject to 4.6.2, the licensee or registrant shall not authorize a planned special exposure that
would cause an individual to receive a dose from all planned special exposures and all doses in
excess of the limits to exceed:
Hazardous Materials and Waste Management
9
4.11.5.1
The numerical values of any of the dose limits in 4.6.1 in any year; and
4.11.5.2
Five times the annual dose limits in 4.6.1 during the individual's lifetime.
4.11.6 The licensee or registrant maintains records of the conduct of a planned special exposure in
accordance with 4.45 and submits a written report in accordance with 4.54.
4.11.7 The licensee or registrant records the best estimate of the dose resulting from the planned
special exposure in the individual's record and informs the individual, in writing, of the dose within
30 days from the date of the planned special exposure. The dose from planned special exposures
shall not be considered in controlling future occupational dose of the individual pursuant to 4.6.1
but shall be included in evaluations required by 4.11.4 and 4.11.5.
4.12
Occupational Dose Limits for Minors.
The annual occupational dose limits for minors are 10 percent of the annual occupational dose
limits specified for adult workers in 4.6.
4.13
Dose Equivalent to an Embryo/Fetus.
4.13.1 The licensee or registrant shall ensure that the dose equivalent to an embryo/fetus during the
entire pregnancy, due to the occupational exposure of a declared pregnant woman, does not
exceed 5 mSv (0.5 rem). See 4.46 for recordkeeping requirements.
4.13.2 The licensee or registrant shall make efforts to avoid substantial variation2 above a uniform
monthly exposure rate to a declared pregnant woman so as to satisfy the limit in 4.13.1.
2 The National Council on Radiation Protection and Measurements recommended in NCRP Report No. 91 “Recommendations on
Limits for Exposure to Ionizing Radiation” (June 1, 1987) that no more than 0.5 mSv (0.05 rem) to the embryo/fetus be received in
any one month.
4.13.3 The dose equivalent to an embryo/fetus is the sum of:
4.13.3.1
The deep dose equivalent to the declared pregnant woman; and
4.13.3.2
The dose equivalent to the embryo/fetus resulting from radionuclides in the
embryo/fetus and radionuclides in the declared pregnant woman.
4.13.4 If the dose equivalent to the embryo/fetus is found to have exceeded 5 mSv (0.5 rem), or is within
0.5 mSv (0.05 rem) of this dose, by the time the woman declares the pregnancy to the licensee or
registrant, the licensee or registrant shall be deemed to be in compliance with 4.13.1 if the
additional dose equivalent to the embryo/fetus does not exceed 0.5 mSv (0.05 rem) during the
remainder of the pregnancy.
RADIATION DOSE LIMITS FOR INDIVIDUAL MEMBERS OF THE PUBLIC
4.14
Dose Limits for Individual Members of the Public.
4.14.1 Each licensee or registrant shall conduct operations so that:
Hazardous Materials and Waste Management
10
4.14.1.1
The total effective dose equivalent to individual members of the public from the
licensed or registered operation does not exceed 1 millisievert (0.1 rem) in a year,
exclusive of the dose contributions from background radiation, from any medical
administration the individual has received, from exposure to individuals administered
radioactive material and released in accordance with 7.26, from voluntary participation in
medical research programs, and from the dose contribution from the licensee's or
registrant's disposal of radioactive material into sanitary sewerage in accordance with
4.35, and
4.14.1.2
The dose in any unrestricted area from external sources, exclusive of the dose
contributions from patients administered radioactive material and released in accordance
with 7.26, does not exceed 0.02 millisievert (0.002 rem) in any one hour.
4.14.2 A licensee may permit visitors to an individual who cannot be released under 7.26 to receive a
radiation dose greater than 1 mSv (0.1 rem) if:
4.14.2.1
The radiation dose received does not exceed 5 mSv (0.5 rem); and
4.14.2.2
The authorized user, as defined in Part 7, has determined before the visit that it
is appropriate.
4.14.3 A licensee, registrant, or an applicant for a license or registration may apply for prior Department
authorization to operate up to an annual dose limit for an individual member of the public of 5
mSv (0.5 rem). This application shall include the following information:
4.14.3.1
Demonstration of the need for and the expected duration of operations in excess
of the limit in 4.14.1; and
4.14.3.2
The licensee's or registrant's program to assess and control dose within the 5
mSv (0.5 rem) annual limit; and
4.14.3.3
The procedures to be followed to maintain the dose ALARA.
4.14.4 In addition to the requirements of Part 4, a licensee or registrant subject to the provisions of the
U.S. Environmental Protection Agency's generally applicable environmental radiation standards
in 40 CFR 190 (July 1, 2004) shall comply with those standards.
4.14.5 The Department may impose additional restrictions on radiation levels in unrestricted areas and
on the total quantity of radionuclides that a licensee or registrant may release in effluents in order
to restrict the collective dose.
4.15
Compliance with Dose Limits for Individual Members of the Public.
4.15.1 The licensee or registrant shall make or cause to be made surveys of radiation levels in
unrestricted areas and radioactive materials in effluents released to unrestricted areas to
demonstrate compliance with the dose limits for individual members of the public in 4.14.
4.15.2 A licensee or registrant shall show compliance with the annual dose limit in 4.14 by:
4.15.2.1
Demonstrating by measurement or calculation that the total effective dose
equivalent to the individual likely to receive the highest dose from the licensed or
registered operation does not exceed the annual dose limit; or
4.15.2.2
Demonstrating that:
Hazardous Materials and Waste Management
11
(1)
The annual average concentrations of radioactive material released in gaseous
and liquid effluents at the boundary of the unrestricted area do not exceed the
values specified in Table 4B2 of Appendix 4B; and
(2)
If an individual were continually present in an unrestricted area, the dose from
external sources would not exceed 0.02 mSv (0.002 rem) in an hour and 0.5 mSv
(0.05 rem) in a year.
4.15.3 Upon approval from the Department, the licensee or registrant may adjust the effluent
concentration values in Appendix 4B, Table 4B2, for members of the public, to take into account
the actual physical and chemical characteristics of the effluents, such as, aerosol size distribution,
solubility, density, radioactive decay equilibrium, and chemical form.
4.15.4 Rooms or areas in which diagnostic x-ray systems are the only source of radiation shall
demonstrate compliance with 4.15.2.1 after construction of a new x-ray facility, after modification
or renovation of an existing x-ray facility, or installation or a new x-ray machine in an existing x-
ray facility when there is a change in primary beam orientation, or a change in primary shielding
due to the modification or renovation of a facility, or where there is a projected increase in the x-
ray workload from that which was used for a prior x-ray shielding design.
4.15.5 Rooms or areas in which only dental intraoral, dental panoramic, mini-c-arm x-ray, or bone
densitometry systems are used, are exempt from the requirements of 4.15.2.1.
TESTING FOR LEAKAGE OR CONTAMINATION OF SEALED SOURCES
4.16
Testing for Leakage or Contamination of Sealed Sources.
4.16.1 The licensee or registrant in possession of any sealed source shall assure that:
4.16.1.1
Each sealed source, except as specified in 4.16.2, is tested for leakage or
contamination and the test results are received before the sealed source is put into use
unless the licensee or registrant has a certificate from the transferor indicating that the
sealed source was tested within 6 months before transfer to the licensee or registrant.
Sources that indicate contamination in excess of 185 Bq (0.005 microcuries) shall not be
put into use.
4.16.1.2
Each sealed source that is not designed to emit alpha particles is tested for
leakage or contamination at intervals not to exceed 6 months or at alternative intervals
approved by the Department, after evaluation of information specified by 3.12.12.2 and
3.12.12.3 of these regulations, an Agreement State, a Licensing State, or the U.S.
Nuclear Regulatory Commission.
4.16.1.3
Each sealed source that is designed to emit alpha particles is tested for leakage
or contamination at intervals not to exceed 3 months or at alternative intervals approved
by the Department, after evaluation of information specified by 3.12.12.2 and 3.12.12.3 of
these regulations, an Agreement State, a Licensing State, or the U.S. Nuclear Regulatory
Commission.
4.16.1.4
For each sealed source that is required to be tested for leakage or
contamination, at any other time there is reason to suspect that the sealed source might
have been damaged or might be leaking, the licensee or registrant shall assure that the
sealed source is tested for leakage or contamination before further use.
Hazardous Materials and Waste Management
12
4.16.1.5
Tests, and evaluations of tests, for leakage for all sealed sources, except
brachytherapy sources manufactured to contain radium, shall be capable of detecting the
presence of 185 Bq (0.005 µCi) of radioactive material on a test sample. Test samples
shall be taken from the sealed source or from the surfaces of the container in which the
sealed source is stored or mounted on which one might expect contamination to
accumulate. For a sealed source contained in a device, test samples are obtained when
the source is in the “off” position.
4.16.1.6
The test for leakage for brachytherapy sources manufactured to contain radium
shall be capable of detecting an absolute leakage rate of 37 Bq (0.001 µCi) of radon-222
in a 24-hour period when the collection efficiency for radon-222 and its decay products
has been determined with respect to collection method, volume and time.
4.16.1.7
Tests for contamination from radium decay products shall be taken on the interior
surface of brachytherapy source storage containers and shall be capable of detecting the
presence of 185 Bq (0.005 µCi) of a radium decay product which has a half-life greater
than 4 days.
4.16.2 A licensee or registrant need not perform test for leakage or contamination on the following
sealed sources:
4.16.2.1
Sealed sources containing only radioactive material with a half-life of less than 30
days;
4.16.2.2
Sealed sources containing only radioactive material as a gas;
4.16.2.3
Sealed sources containing 3.7 MBq (100 µCi) or less of beta or photon-emitting
material or 370 kBq (10 µCi) or less of alpha-emitting material;
4.16.2.4
Sealed sources containing only hydrogen-3;
4.16.2.5
Seeds of iridium-192 encased in nylon ribbon; and
4.16.2.6
Sealed sources, except teletherapy and brachytherapy sources, which are
stored, not being used and identified as in storage. The licensee or registrant shall,
however, test each such sealed source for leakage or contamination and receive the test
results before any use or transfer unless it has been tested for leakage or contamination
within 6 months before the date of use or transfer.
4.16.3 Tests for leakage or contamination from sealed sources shall be performed by persons
specifically authorized by the Department, an Agreement State, a Licensing State, or the U.S.
Nuclear Regulatory Commission to perform such services.
4.16.4 Test results shall be kept in units of becquerel (or microcurie) and maintained for inspection by
the Department. Records of test results for sealed sources shall be made and retained as
specified in 4.43.
4.16.5 The following shall be considered evidence that a sealed source is leaking:
4.16.5.1
The presence of 185 Bq (0.005 µCi) or more of removable contamination on any
test sample.
4.16.5.2
Leakage of 37 Bq (0.001 µCi) of radon-222 per 24 hours for brachytherapy
sources manufactured to contain radium.
Hazardous Materials and Waste Management
13
4.16.5.3
The presence of removable contamination resulting from the decay of 185 Bq
(0.005 µCi) or more of radium.
4.16.6 The licensee or registrant shall immediately withdraw a leaking sealed source from use and shall
take action to prevent the spread of contamination. The leaking sealed source shall be repaired
or disposed of in accordance with this Part.
4.16.7 Reports of test results for leaking or contaminated sealed sources shall be made pursuant to
4.58.
SURVEYS AND MONITORING
4.17
General.
4.17.1 Each licensee or registrant shall make, or cause to be made, surveys of areas, including areas of
subsurface radioactivity identified at the site, that:
4.17.1.1
Are necessary for the licensee or registrant to comply with Part 4; and
4.17.1.2
Are necessary under the circumstances to evaluate:
(1)
The magnitude and extent of radiation levels; and
(2)
Concentrations or quantities of residual radioactivity; and
(3)
The potential radiological hazards.
4.17.2 Notwithstanding 4.42.1, records from surveys describing the location and amount of subsurface
residual radioactivity identified at the site must be kept with records important for
decommissioning, and such records must be retained in accordance with 3.16.5, as applicable.
4.17.3 The licensee or registrant shall ensure that instruments and equipment used for quantitative
radiation measurements, for example, dose rate and effluent monitoring, are calibrated at
intervals not to exceed 12 months for the radiation measured unless otherwise noted in these
regulations.
4.17.4 All personnel dosimeters, except for direct and indirect reading pocket ionization chambers and
those dosimeters used to measure the dose to any extremity, that require processing to
determine the radiation dose and that are used by licensees and registrants to comply with 4.6,
with other applicable provisions of these regulations, or with conditions specified in a license or
registration shall be processed and evaluated by a dosimetry processor:
4.17.4.1
Holding current personnel dosimetry accreditation from the National Voluntary
Laboratory Accreditation Program (NVLAP) of the National Institute of Standards and
Technology; and
4.17.4.2
Approved in this accreditation process for the type of radiation or radiations
included in the NVLAP program that most closely approximates the type of radiation or
radiations for which the individual wearing the dosimeter is monitored.
4.17.5 The licensee or registrant shall ensure that adequate precautions are taken to prevent a
deceptive exposure of an individual monitoring device.
Hazardous Materials and Waste Management
14
4.18
Conditions Requiring Individual Monitoring of External and Internal Occupational Dose.
Each licensee or registrant shall monitor exposures from sources of radiation at levels sufficient
to demonstrate compliance with the occupational dose limits of Part 4. As a minimum:
4.18.1 Each licensee or registrant shall monitor occupational exposure to radiation from licensed and
unlicensed radiation sources under the control of the licensee or the registrant and shall supply
and require the use of individual monitoring devices by:
4.18.1.1
Adults likely to receive, in 1 year from sources external to the body, a dose in
excess of 10 percent of the limits in 4.6.1;
4.18.1.2
Minors likely to receive, in 1 year from radiation sources external to the body, a
deep dose equivalent in excess of 1 mSv (0.1 rem), a lens dose equivalent in excess of
1.5 mSv (0.15 rem), or a shallow dose equivalent to the skin or to the extremities in
excess 5 mSv (0.5 rem);
4.18.1.3
Declared pregnant women likely to receive during the entire pregnancy, from
radiation sources external to the body, a deep dose equivalent in excess of 1 mSv (0.1
rem)3; and
3 All of the occupational doses in 4.6 continue to be applicable to the declared pregnant worker as long as the embryo/fetus dose
limit is not exceeded.
4.18.1.4
Individuals entering a high radiation area or a very high radiation area.
4.18.2 Each licensee or registrant shall monitor, to determine compliance with 4.9, the occupational
intake of radioactive material by and assess the committed effective dose equivalent to:
4.18.2.1
Adults likely to receive, in 1 year, an intake in excess of 10 percent of the
applicable ALI(s) in Table 4B1, Columns 1 and 2, of Appendix 4B;
4.18.2.2
Minors likely to receive, in 1 year, a committed effective dose equivalent in
excess of 1 mSv (0.1 rem); and
4.18.2.3
Declared pregnant women likely to receive during the entire pregnancy, a
committed effective dose equivalent in excess of 1 mSv (0.1 rem).
4.18.3 Registrants shall maintain records of the evaluation of likely external dose and the determination
to monitor or not monitor individuals to demonstrate compliance with the occupational dose limits
of Part 4. The registrant shall retain the record required by 4.18.3 for inspection until the
Department terminates the registration requiring the record.
CONTROL OF EXPOSURE FROM EXTERNAL SOURCES IN RESTRICTED AREAS
4.19
Control of Access to High Radiation Areas.
4.19.1 The licensee or registrant shall ensure that each entrance or access point to a high radiation area
has one or more of the following features:
4.19.1.1
A control device that, upon entry into the area, causes the level of radiation to be
reduced below that level at which an individual might receive a deep dose equivalent of 1
mSv (0.1 rem) in 1 hour at 30 centimeters from the source of radiation from any surface
that the radiation penetrates; or
Hazardous Materials and Waste Management
15
4.19.1.2
A control device that energizes a conspicuous visible or audible alarm signal so
that the individual entering the high radiation area and the supervisor of the activity are
made aware of the entry; or
4.19.1.3
Entryways that are locked, except during periods when access to the areas is
required, with positive control over each individual entry.
4.19.2 In place of the controls required by 4.19.1 for a high radiation area, the licensee or registrant may
substitute continuous direct or electronic surveillance that is capable of preventing unauthorized
entry.
4.19.3 The licensee or registrant may apply to the Department for approval of alternative methods for
controlling access to high radiation areas.
4.19.4 The licensee or registrant shall establish the controls required by 4.19.1 and 4.19.3 in a way that
does not prevent individuals from leaving a high radiation area.
4.19.5 The licensee or registrant is not required to control each entrance or access point to a room or
other area that is a high radiation area solely because of the presence of radioactive materials
prepared for transport and packaged and labeled in accordance with the regulations of the U.S.
Department of Transportation provided that:
4.19.5.1
The packages do not remain in the area longer than 3 days; and
4.19.5.2
The dose rate at 1 meter from the external surface of any package does not
exceed 0.1 mSv (0.01 rem) per hour.
4.19.6 The licensee or registrant is not required to control entrance or access to rooms or other areas in
hospitals solely because of the presence of patients containing radioactive material, provided that
there are personnel in attendance who are taking the necessary precautions to prevent the
exposure of individuals to radiation or radioactive material in excess of the established limits in
Part 4 and to operate within the ALARA provisions of the licensee's or registrant's radiation
protection program.
4.19.7 The licensee or registrant is not required to control entrance or access to rooms or other areas
containing sources of radiation capable of producing a high radiation area as described in 4.19 if
the licensee or registrant has met all the specific requirements for access and control specified in
other applicable parts of these regulations, such as, Part 5 for industrial radiography, Part 6 for x-
rays in the healing arts, and Part 9 for particle accelerators not used in the healing arts.
4.20
Control of Access to Very High Radiation Areas.
4.20.1 In addition to the requirements in 4.19, the licensee or registrant shall institute measures to
ensure that an individual is not able to gain unauthorized or inadvertent access to areas in which
radiation levels could be encountered at 5 Gy (500 rad) or more in 1 hour at 1 meter from a
source of radiation or any surface through which the radiation penetrates. This requirement does
not apply to rooms or areas in which diagnostic x-ray systems are the only source of radiation, or
to non-self-shielded irradiators.
4.20.2 The registrant is not required to control entrance or access to rooms or other areas containing
sources of radiation capable of producing a very high radiation area as described in 4.20.1 if the
registrant has met all the specific requirements for access and control specified in other
applicable parts of these regulations, such as, Part 5 for industrial radiography, Part 6 for x-rays
in the healing arts, and Part 9 for particle accelerators not used in the healing arts.
Hazardous Materials and Waste Management
16
4.21
Control of Access to Very High Radiation Areas - Irradiators.
4.21.1 Section 4.21 applies to licensees or registrants with sources of radiation in non-self-shielded
irradiators. Section 4.21 does not apply to sources of radiation that are used in teletherapy, in
industrial radiography, or in completely self-shielded irradiators in which the source of radiation is
both stored and operated within the same shielding radiation barrier and, in the designed
configuration of the irradiator, is always physically inaccessible to any individual and cannot
create high levels of radiation in an area that is accessible to any individual.
4.21.2 Each area in which there may exist radiation levels in excess of 5 Gy (500 rad) in 1 hour at 1
meter from a source of radiation that is used to irradiate materials shall meet the following
requirements:
4.21.2.1
Each entrance or access point shall be equipped with entry control devices
which:
(1)
Function automatically to prevent any individual from inadvertently entering a
very high radiation area; and
(2)
Permit deliberate entry into the area only after a control device is actuated that
causes the radiation level within the area, from the source of radiation, to be
reduced below that at which it would be possible for an individual to receive a
deep dose equivalent in excess of 1 mSv (0.1 rem) in 1 hour; and
(3)
Prevent operation of the source of radiation if it would produce radiation levels in
the area that could result in a deep dose equivalent to an individual in excess of
1 mSv (0.1 rem) in 1 hour.
4.21.2.2
Additional control devices shall be provided so that, upon failure of the entry
control devices to function as required by 4.21.2.1:
(1)
The radiation level within the area, from the source of radiation, is reduced below
that at which it would be possible for an individual to receive a deep dose
equivalent in excess of 1 mSv (0.1 rem) in 1 hour; and
(2)
Conspicuous visible and audible alarm signals are generated to make an
individual attempting to enter the area aware of the hazard and at least one other
authorized individual, who is physically present, familiar with the activity, and
prepared to render or summon assistance, aware of the failure of the entry
control devices.
4.21.2.3
The licensee or registrant shall provide control devices so that, upon failure or
removal of physical radiation barriers other than the sealed source's shielded storage
container:
(1)
The radiation level from the source of radiation is reduced below that at which it
would be possible for an individual to receive a deep dose equivalent in excess
of 1 mSv (0.1 rem) in 1 hour; and
(2)
Conspicuous visible and audible alarm signals are generated to make potentially
affected individuals aware of the hazard and the licensee or registrant or at least
one other individual, who is familiar with the activity and prepared to render or
summon assistance, aware of the failure or removal of the physical barrier.
Hazardous Materials and Waste Management
17
4.21.2.4
When the shield for stored sealed sources is a liquid, the licensee or registrant
shall provide means to monitor the integrity of the shield and to signal, automatically, loss
of adequate shielding.
4.21.2.5
Physical radiation barriers that comprise permanent structural components, such
as walls, that have no credible probability of failure or removal in ordinary circumstances
need not meet the requirements of 4.21.2.3 and 4.21.2.4.
4.21.2.6
Each area shall be equipped with devices that will automatically generate
conspicuous visible and audible alarm signals to alert personnel in the area before the
source of radiation can be put into operation and in time for any individual in the area to
operate a clearly identified control device, which must be installed in the area and which
can prevent the source of radiation from being put into operation.
4.21.2.7
Each area shall be controlled by use of such administrative procedures and such
devices as are necessary to ensure that the area is cleared of personnel prior to each
use of the source of radiation.
4.21.2.8
Each area shall be checked by a radiation measurement to ensure that, prior to
the first individual's entry into the area after any use of the source of radiation, the
radiation level from the source of radiation in the area is below that at which it would be
possible for an individual to receive a deep dose equivalent in excess of 1 mSv (0.1 rem)
in 1 hour.
4.21.2.9
The entry control devices required in 4.21.2.1 shall be tested for proper
functioning. See 4.49 for recordkeeping requirements.
(1)
Testing shall be conducted prior to initial operation with the source of radiation on
any day, unless operations were continued uninterrupted from the previous day;
and
(2)
Testing shall be conducted prior to resumption of operation of the source of
radiation after any unintentional interruption; and
(3)
The licensee or registrant shall submit and adhere to a schedule for periodic
tests of the entry control and warning systems.
4.21.2.10
The licensee or registrant shall not conduct operations, other than those
necessary to place the source of radiation in safe condition or to effect repairs on
controls, unless control devices are functioning properly.
4.21.2.11
Entry and exit portals that are used in transporting materials to and from the
irradiation area, and that are not intended for use by individuals, shall be controlled by
such devices and administrative procedures as are necessary to physically protect and
warn against inadvertent entry by any individual through these portals. Exit portals for
irradiated materials shall be equipped to detect and signal the presence of any loose
radioactive material that is carried toward such an exit and to automatically prevent loose
radioactive material from being carried out of the area.
Hazardous Materials and Waste Management
18
4.21.3 Licensees, registrants, or applicants for licenses or registrations for sources of radiation within the
purview of 4.21.2 which will be used in a variety of positions or in locations, such as open fields or
forests, that make it impracticable to comply with certain requirements of 4.21.2, such as those
for the automatic control of radiation levels, may apply to the Department for approval of
alternative safety measures. Alternative safety measures shall provide personnel protection at
least equivalent to those specified in 4.21.2. At least one of the alternative measures shall include
an entry-preventing interlock control based on a measurement of the radiation that ensures the
absence of high radiation levels before an individual can gain access to the area where such
sources of radiation are used.
4.21.4 The entry control devices required by 4.21.2 and 4.21.3 shall be established in such a way that
no individual will be prevented from leaving the area.
RESPIRATORY PROTECTION AND CONTROLS TO RESTRICT INTERNAL EXPOSURE IN
RESTRICTED AREAS
4.22
Use of Process or Other Engineering Controls.
The licensee shall use, to the extent practical, process or other engineering controls, such as
containment, decontamination or ventilation, to control the concentrations of radioactive material
in air.
4.23
Use of Other Controls.
4.23.1 When it is not practical to apply process or other engineering controls to control the
concentrations of radioactive material in air to values below those that define an airborne
radioactivity area, the licensee shall, consistent with maintaining the total effective dose
equivalent ALARA, increase monitoring and limit intakes by one or more of the following means:
4.23.1.1
Control of access; or
4.23.1.2
Limitation of exposure times; or
4.23.1.3
Use of respiratory protection equipment; or
4.23.1.4
Other controls.
4.23.2 If the licensee performs an ALARA analysis to determine whether or not respirators should be
used, the licensee may consider safety factors other than radiological factors. The licensee
should also consider the impact of respirator use on workers' industrial health and safety.
4.24
Use of Individual Respiratory Protection Equipment.
4.24.1 If the licensee uses respiratory protection equipment to limit intakes pursuant to 4.23:
4.24.1.1
Except as provided in 4.24.1.2, the licensee shall use only respiratory protection
equipment that is tested and certified or had certification extended by the National
Institute for Occupational Safety and Health and the Mine Safety and Health
Administration.
Hazardous Materials and Waste Management
19
4.24.1.2
If the licensee wishes to use equipment that has not been tested or certified by
the National Institute for Occupational Safety and Health and the Mine Safety and Health
Administration, or has not had certification extended by the National Institute for
Occupational Safety and Health and the Mine Safety and Health Administration, or for
which there is no schedule for testing or certification, the licensee shall submit an
application for authorized use of that equipment, including a demonstration by testing, or
a demonstration on the basis of reliable test information, that the material and
performance characteristics of the equipment are capable of providing the proposed
degree of protection under anticipated conditions of use.
4.24.1.3
The licensee shall implement and maintain a respiratory protection program that
includes:
(1)
Air sampling sufficient to identify the potential hazard, permit proper equipment
selection, and estimate exposures; and
(2)
Surveys and bioassays, as appropriate, to evaluate actual intakes; and
(3)
Testing of respirators for operability (user seal check for face sealing devices and
functional check for others) immediately prior to each use; and
(4)
Written procedures regarding selection, fitting, issuance, maintenance, repair,
quality assurance, storage and testing of respirators, including testing for
operability immediately prior to each use; supervision and training of personnel;
limitations on periods of respirator use and relief from respirator use; breathing
air quality; monitoring, including air sampling and bioassays; inventory, control
and recordkeeping; and
(5)
Determination by a physician, prior to initial fitting of respirators, before the first
field use of non-face-sealing respirators, and either every 12 months thereafter or
periodically at a frequency determined by a physician, that the individual user is
medically fit to use the respiratory protection equipment.
(6)
Fit testing, with fit factor 10 times the assigned protection factor (APF) for
negative pressure devices, and a fit factor greater than or equal to 500 for any
positive pressure, continuous flow, and pressure demand devices, before the first
field use of tight-fitting, face-sealing respirators and periodically thereafter at a
frequency not to exceed 1 year. Fit testing must be performed with the facepiece
operating in the negative pressure mode.
4.24.1.4
The licensee shall:
(1)
Issue a written policy statement on respirator usage covering:
(a)
The use of process or other engineering controls, instead of respirators;
and
(b)
The routine, nonroutine, and emergency use of respirators; and
(c)
The length of periods of respirator use and relief from respirator use; and
Hazardous Materials and Waste Management
20
(2)
Advise each respirator user that the user may leave the area at any time for relief
from respirator use in the event of equipment malfunction, physical or
psychological distress, procedural or communication failure, significant
deterioration of operating conditions, or any other conditions that might require
such relief.
4.24.1.5
The licensee shall also consider limitations appropriate to the type and mode of
use. When selecting respiratory devices the licensee shall provide for vision correction,
adequate communication, low temperature work environments, and the concurrent use of
other safety or radiological protection equipment. The licensee shall use equipment in
such a way as not to interfere with the proper operation of the respirator.
4.24.1.6
Standby rescue persons are required whenever one piece atmosphere supplying
suits, or any combination of supplied air respiratory protection device and personnel
protective equipment are used from which an unaided individual would have difficulty
extricating himself or herself. The standby persons must be equipped with respiratory
protection devices or other apparatus appropriate for the potential hazards. The standby
rescue persons shall observe or otherwise maintain continuous communication with the
workers (visual, voice, signal line, telephone, radio, or other suitable means), and be
immediately available to assist them in case of a failure of the air supply or for any other
reason that requires relief from distress. A sufficient number of standby rescue persons
must be immediately available to assist all users of this type of equipment and to provide
effective emergency rescue if needed.
4.24.1.7
Atmosphere-supplying respirators must be supplied with respirable air of Grade
D quality or better as defined by the Compressed Gas Association in Publication G-7.1,
“Commodity Specification For Air,” edition 5, published August 27, 2004, and included in
the regulations of the Occupational Safety And Health Administration (29 CFR
1910.134(i)(1)(ii)(A) through (E), July 1, 2004).
Grade D quality air criteria include:
(1)
Oxygen content (V/V) between 19.5 per cent and 23.5 per cent;
(2)
Hydrocarbon (condensed) content of 5 milligrams per cubic meter of air or less;
(3)
Carbon monoxide (CO) content of 10 parts per million or less;
(4)
Carbon dioxide content of 1,000 parts per million or less; and
(5)
Lack of noticeable odor.
4.24.1.8
The licensee shall ensure that no objects, materials or substances, such as facial
hair, or any conditions that interfere with the face, facepiece seal or valve function, and
that are under the control of the respirator wearer, are present between the skin of the
wearer's face and the sealing surface of a tight fitting respirator facepiece.
4.24.1.9
In estimating the dose to individuals from intake of airborne radioactive materials,
the concentration of radioactive material in the air that is inhaled when respirators are
worn is initially assumed to be the ambient concentration in air without respiratory
protection, divided by the assigned protection factor. If the dose is later found to be
greater than the estimated dose, the corrected value must be used. If the dose is later
found to be less than the estimated dose, the corrected value may be used.
Hazardous Materials and Waste Management
21
4.24.2 When estimating exposure of individuals to airborne radioactive materials, the licensee may make
allowance for respiratory protection equipment used to limit intakes pursuant to 4.23, provided
that the following conditions, in addition to those in 4.24.1, are satisfied:
4.24.2.1
The licensee selects respiratory protection equipment that provides a protection
factor, specified in Appendix 4A, greater than the multiple by which peak concentrations
of airborne radioactive materials in the working area are expected to exceed the values
specified in Appendix 4B, Table 4B1, Column 3. However, if the selection of respiratory
protection equipment with a protection factor greater than the multiple defined in the
preceding sentence is inconsistent with the goal specified in 4.23 of keeping the total
effective dose equivalent ALARA, the licensee may select respiratory protection
equipment with a lower protection factor provided that such a selection would result in a
total effective dose equivalent that is ALARA. The concentration of radioactive material in
the air that is inhaled when respirators are worn may be initially estimated by dividing the
average concentration in air, during each period of uninterrupted use, by the protection
factor. If the exposure is later found to be greater than initially estimated, the corrected
value shall be used; if the exposure is later found to be less than initially estimated, the
corrected value may be used.
4.24.2.2
The licensee shall obtain authorization from the Department before assigning
respiratory protection factors in excess of those specified in Appendix 4A. The
Department may authorize a licensee to use higher protection factors on receipt of an
application that:
(1)
Describes the situation for which a need exists for higher protection factors, and
(2)
Demonstrates that the respiratory protection equipment provides these higher
protection factors under the proposed conditions of use.
4.24.3 In an emergency, the licensee shall use as emergency equipment only respiratory protection
equipment that has been specifically certified or had certification extended for emergency use by
the National Institute for Occupational Safety and Health and the Mine Safety and Health
Administration.
4.24.4 The licensee shall notify the Department in writing at least 30 days before the date that
respiratory protection equipment is first used pursuant to either 4.24.1 or 4.24.2.
4.24.5 The Department may impose restrictions in addition to the provisions of 4.23.2, 4.24.1, and
Appendix 4A, in order to:
4.24.5.1
Ensure that the respiratory protection program of the licensee is adequate to limit
doses to individuals from intakes of airborne radioactive materials consistent with
maintaining total effective dose equivalent ALARA; and
4.24.5.2
Limit the extent to which a licensee may use respiratory protection equipment
instead of process or other engineering controls.
STORAGE AND CONTROL OF LICENSED OR REGISTERED SOURCES OF RADIATION
4.25
Security of Stored Sources of Radiation.
4.25.1 The licensee shall secure from unauthorized removal or access licensed or registered sources of
radiation that are stored in unrestricted areas.
Hazardous Materials and Waste Management
22
4.25.2 Security requirements for portable gauges.
Each portable gauge licensee shall use a minimum of two independent physical controls that form
tangible barriers to secure portable gauges from unauthorized removal, whenever portable
gauges are not under the control and constant surveillance of the licensee.
4.26
Control of Sources of Radiation not in Storage.
4.26.1 The licensee shall control and maintain constant surveillance of licensed or registered radioactive
material that is in an unrestricted area and that is not in storage or in a patient.
4.26.2 The registrant shall maintain control of radiation machines that are in an unrestricted area and
that are not in storage.
PRECAUTIONARY PROCEDURES
4.27
Caution Signs.
4.27.1 Standard Radiation Symbol. Unless otherwise authorized by the Department, the symbol
prescribed by 4.27 shall use the colors magenta, or purple, or black on yellow background. The
symbol prescribed is the three-bladed design as follows:
RADIATION SYMBOL
4.27.1.1.
Cross-hatched area is to be magenta, or purple, or black, and
4.27.1.2.
The background is to be yellow.
Hazardous Materials and Waste Management
23
4.27.2 Exception to Color Requirements for Standard Radiation Symbol.
Notwithstanding the requirements of 4.27.1, licensees or registrants are authorized to label
sources, source holders, or device components containing sources of radiation that are subjected
to high temperatures, with conspicuously etched or stamped radiation caution symbols and
without a color requirement.
4.27.3 Additional Information on Signs and Labels.
In addition to the contents of signs and labels prescribed in Part 4, the licensee may provide, on
or near the required signs and labels, additional information, as appropriate, to make individuals
aware of potential radiation exposures and to minimize the exposures.
4.28
Posting Requirements.
4.28.1 Posting of Radiation Areas.
The licensee or registrant shall post each radiation area with a conspicuous sign or signs bearing
the radiation symbol prescribed in 4.27 and the words “CAUTION, RADIATION AREA.”
4.28.2 Posting of High Radiation Areas.
The licensee or registrant shall post each high radiation area with a conspicuous sign or signs
bearing the radiation symbol prescribed in 4.27 and the words “CAUTION, HIGH RADIATION
AREA” or “DANGER, HIGH RADIATION AREA.”
4.28.3 Posting of Very High Radiation Areas.
The licensee or registrant shall post each very high radiation area with a conspicuous sign or
signs bearing the radiation symbol prescribed in 4.27 and words “GRAVE DANGER, VERY HIGH
RADIATION AREA.”
4.28.4 Posting of Airborne Radioactivity Areas.
The licensee or registrant shall post each airborne radioactivity area with a conspicuous sign or
signs bearing the radiation symbol prescribed in 4.27 and the words “CAUTION, AIRBORNE
RADIOACTIVITY AREA” or “DANGER, AIRBORNE RADIOACTIVITY AREA.”
4.28.5 Posting of Areas or Rooms in which Licensed or Registered Material is Used or Stored.
The licensee or registrant shall post each area or room in which there is used or stored an
amount of licensed or registered material exceeding 10 times the quantity of such material
specified in Appendix 4C with a conspicuous sign or signs bearing the radiation symbol
prescribed in 4.27 and the words “CAUTION, RADIOACTIVE MATERIAL(S)” or “DANGER,
RADIOACTIVE MATERIAL(S).”
4.29
Exceptions to Posting Requirements.
4.29.1 A licensee or registrant is not required to post caution signs in areas or rooms containing sources
of radiation for periods of less than 8 hours, if each of the following conditions is met:
4.29.1.1
The sources of radiation are constantly attended during these periods by an
individual who takes the precautions necessary to prevent the exposure of individuals to
sources of radiation in excess of the limits established in Part 4; and
Hazardous Materials and Waste Management
24
4.29.1.2
The area or room is subject to the licensee's or registrant's control.
4.29.2 Rooms or other areas in hospitals that are occupied by patients are not required to be posted with
caution signs pursuant to 4.28 provided that the total effective dose equivalent to individual
members of the public from the patient does not exceed 1 millisievert (0.1 rem) in a year.
4.29.3 A room or area is not required to be posted with a caution sign because of the presence of a
sealed source provided the radiation level at 30 centimeters from the surface of the sealed source
container or housing does not exceed 0.05 mSv (0.005 rem) per hour.
4.29.4 Rooms in hospitals or clinics that are used for teletherapy are exempt from the requirement to
post caution signs under 4.28 if:
4.29.4.1
Access to the room is controlled pursuant to 7.52; and
4.29.4.2
Personnel in attendance take necessary precautions to prevent the inadvertent
exposure of workers, other patients, and members of the public to radiation in excess of
the limits established in this part.
4.29.5 A room or area is not required to be posted with a caution sign because of the presence of
radiation machines used solely for diagnosis in the healing arts.
4.30
Labeling Containers and Radiation Machines.
4.30.1 The licensee or registrant shall ensure that each container of licensed or registered material
bears a durable, clearly visible label bearing the radiation symbol prescribed in 4.27 and the
words “CAUTION, RADIOACTIVE MATERIAL” or “DANGER, RADIOACTIVE MATERIAL.” The
label shall also provide information, such as the radionuclides present, an estimate of the quantity
of radioactivity, the date for which the activity is estimated, radiation levels, kinds of materials,
and mass enrichment, to permit individuals handling or using the containers, or working in the
vicinity of the containers, to take precautions to avoid or minimize exposures.
4.30.2 Each licensee or registrant shall, prior to removal or disposal of empty uncontaminated containers
to unrestricted areas, remove or deface the radioactive material label or otherwise clearly indicate
that the container no longer contains radioactive materials.
4.30.3 Each registrant shall ensure that each radiation machine is labeled in a conspicuous manner,
which cautions individuals that radiation is produced when it is energized.
4.31
Exemptions to Labeling Requirements.
A licensee or registrant is not required to label:
4.31.1 Containers holding licensed or registered material in quantities less than the quantities listed in
Appendix 4C; or
4.31.2 Containers holding licensed or registered material in concentrations less than those specified in
Table 4B3 of Appendix 4B; or
4.31.3 Containers attended by an individual who takes the precautions necessary to prevent the
exposure of individuals in excess of the limits established by Part 4; or
Hazardous Materials and Waste Management
25
4.31.4 Containers when they are in transport and packaged and labeled in accordance with the
regulations of the U.S. Department of Transportation4 or
4 Labeling of packages containing radioactive materials is required by the U.S. Department of Transportation if the amount and type
of radioactive material exceeds the limits for an excepted quantity or article as defined and limited by U.S. Department of
Transportation regulations 49 CFR 173.403(m) and (w) and 173.421-424, October 1, 2003.
4.31.5 Containers that are accessible only to individuals authorized to handle or use them, or to work in
the vicinity of the containers, if the contents are identified to these individuals by a readily
available written record. Examples of containers of this type are containers in locations such as
water-filled canals, storage vaults, or hot cells. The record shall be retained as long as the
containers are in use for the purpose indicated on the record; or
4.31.6 Installed manufacturing or process equipment, such as piping and tanks.
4.32
Procedures for Receiving and Opening Packages.
4.32.1 Each licensee or registrant who expects to receive a package containing quantities of radioactive
material in excess of a Type A quantity, as defined in 17.2 and Appendix 17A of Part 17 of these
regulations, shall make arrangements to receive:
4.32.1.1
The package when the carrier offers it for delivery; or
4.32.1.2
The notification of the arrival of the package at the carrier's terminal and to take
possession of the package expeditiously.
4.32.2 Each licensee or registrant shall:
4.32.2.1
Monitor the external surfaces of a labeled5 package for radioactive contamination
unless the package contains only radioactive material in the form of gas or in special form
as defined in 1.2 of these regulations; and
5 Labeled with a Radioactive White I, Yellow II, or Yellow III label as specified in U.S. Department of Transportation regulations 49
CFR 172.403 and 172.436-440, October 1, 2003.
4.32.2.2
Monitor the external surfaces of a labeled6 package for radiation levels unless the
package contains quantities of radioactive material that are less than or equal to the Type
A quantity, as defined in 17.2 and Appendix 17A to Part 17 of these regulations; and
6 Labeled with a Radioactive White I, Yellow II, or Yellow III label as specified in U.S. Department of Transportation regulations 49
CFR 172.403 and 172.436-440, October 1, 2003.
4.32.2.3
Monitor all packages known to contain radioactive material for radioactive
contamination and radiation levels if there is evidence of degradation of package
integrity, such as packages that are crushed, wet, or damaged.
4.32.3 The licensee or registrant shall perform the monitoring required by 4.32.2 as soon as practical
after receipt of the package, but not later than 3 hours after the package is received at the
licensee's or registrant's facility if it is received during the licensee's or registrant's normal working
hours, or not later than 3 hours from the beginning of the next working day if it is received after
working hours.
4.32.4 The licensee or registrant shall immediately notify the final delivery carrier and the Department by
telephone, when:
4.32.4.1
Removable radioactive surface contamination exceeds the limits of 17.15.8 of
these regulations; or
Hazardous Materials and Waste Management
26
4.32.4.2
External radiation levels exceed the limits of 17.15.9 and 17.15.10 of these
regulations.
4.32.5 Each licensee or registrant shall:
4.32.5.1
Establish, maintain, and retain written procedures for safely opening packages in
which radioactive material is received; and
4.32.5.2
Ensure that the procedures are followed and that due consideration is given to
special instructions for the type of package being opened.
4.32.6 Licensees or registrants transferring special form sources in vehicles owned or operated by the
licensee or registrant to and from a work site are exempt from the contamination monitoring
requirements of 4.32.2, but are not exempt from the monitoring requirement in 4.32.2 for
measuring radiation levels that ensures that the source is still properly lodged in its shield.
WASTE DISPOSAL
4.33
General Requirements.
4.33.1 A licensee or registrant shall dispose of licensed or registered material only:
4.33.1.1
By transfer to an authorized recipient as provided in 4.38 or in Parts 3, 14, or 18
of these regulations, or to the U.S. Department of Energy; or
4.33.1.2
By decay in storage in accordance with the following:
(1)
A licensee may hold radioactive material with a physical half-life of less than or
equal to 120 days for decay-in-storage before disposal without regard for its
radioactivity if the licensee:
(a)
Monitors radioactive material at the container surface before disposal
and determines that its radioactivity cannot be distinguished from the
background radiation level with a radiation detection survey instrument
set on its most sensitive scale and with no interposed shielding; and
(b)
Removes or obliterates all radiation labels, except for material that will be
handled as biomedical waste after release;
or
4.33.1.3
By release in effluents within the limits in 4.14; or
4.33.1.4
As authorized pursuant to 4.34, 4.35, 4.36, 4.37 or 4.39.2
4.33.2 A person shall be specifically licensed or registered to receive waste containing licensed or
registered material from other persons for:
4.33.2.1
Treatment prior to disposal; or
4.33.2.2
Treatment or disposal by incineration; or
4.33.2.3
Decay in storage; or
Hazardous Materials and Waste Management
27
4.33.2.4
Disposal at a land disposal facility pursuant to Part 14 of these regulations or as
authorized under Parts 3 or 18 of these regulations; or
4.33.2.5
Storage until transferred to a storage or disposal facility authorized to receive the
waste.
4.34
Method for Obtaining Approval of Proposed Disposal Procedures.
A licensee or registrant or applicant for a license or registration may apply to the Department for
approval of proposed procedures, not otherwise authorized in these regulations, to dispose of
licensed or registered material generated in the licensee's or registrant's operations. Each
application shall include:
4.34.1 A description of the waste containing licensed or registered material to be disposed of, including
the physical and chemical properties that have an impact on risk evaluation, and the proposed
manner and conditions of waste disposal; and
4.34.2 An analysis and evaluation of pertinent information on the nature of the environment; and
4.34.3 The nature and location of other potentially affected facilities; and
4.34.4 Analyses and procedures to ensure that doses are maintained ALARA and within the dose limits
in Part 4.
4.35
Disposal by Release into Sanitary Sewerage.
4.35.1 A licensee or registrant may discharge licensed or registered material into sanitary sewerage if
each of the following conditions is satisfied:
4.35.1.1
The material is “readily soluble,” or is “readily dispersible biological material,” in
water; and
4.35.1.2
The quantity of licensed or registered radioactive material that the licensee or
registrant releases into the sewer in 1 month divided by the average monthly volume of
water released into the sewer by the licensee or registrant does not exceed the
concentration listed in Table 4B3 of Appendix 4B; and
4.35.1.3
If more than one radionuclide is released, the following conditions must also be
satisfied:
(1)
The licensee or registrant shall determine the fraction of the limit in Table 4B3 of
Appendix 4B represented by discharges into sanitary sewerage by dividing the
actual monthly average concentration of each radionuclide released by the
licensee or registrant into the sewer by the concentration of that radionuclide
listed in Table 4B3 of Appendix 4B; and
(2)
The sum of the fractions for each radionuclide required by 4.35.1.3.(1) does not
exceed unity; and
4.35.1.4
The total quantity of licensed or registered radioactive material that the licensee
or registrant releases into the sanitary sewerage in a year does not exceed 185 GBq (5
Ci) of hydrogen-3, 37 GBq (1 Ci) of carbon-14, and 37 GBq (1 Ci) of all other radioactive
materials combined.
Hazardous Materials and Waste Management
28
4.35.2 Excreta from individuals undergoing medical diagnosis or therapy with radioactive material are
not subject to the limitations contained in 4.35.1.
4.36
Treatment or Disposal by Incineration.
4.36.1 A licensee or registrant may treat or dispose of licensed or registered material by incineration only
in the amounts and forms specified in 4.37 or as specifically approved by the Department
pursuant to 4.34.
4.37
Disposal of Specific Wastes.
4.37.1 A licensee or registrant may dispose of the following licensed or registered material as if it were
not radioactive:
4.37.1.1
1.85 kBq (0.05 µCi), or less, of hydrogen-3 or carbon-14 per gram of medium
used for liquid scintillation counting; and
4.37.1.2
1.85 kBq (0.05 µCi), or less, of hydrogen-3 or carbon-14 per gram of animal
tissue, averaged over the weight of the entire animal.
4.37.2 A licensee or registrant shall not dispose of tissue pursuant to 4.37.1.2 in a manner that would
permit its use either as food for humans or as animal feed.
4.37.3 The licensee or registrant shall maintain records in accordance with 4.48.
4.38
Transfer for Disposal and Manifests.
4.38.1 The requirements of 4.38 and Appendix 4D are designed to control transfers of low-level
radioactive waste by any waste generator, waste collector, or waste processor licensee, as
defined in this part, who ships low-level waste either directly, or indirectly through a waste
collector or waste processor, to a licensed low-level radioactive waste disposal facility, establish a
manifest tracking system, and supplement existing requirements concerning transfers and
recordkeeping for those wastes.
4.38.2 Any licensee shipping radioactive waste intended for ultimate disposal at a licensed land disposal
facility shall document the information required on the uniform low-level radioactive waste
manifest and transfer this recorded manifest information to the intended consignee in accordance
with Appendix 4D.
4.38.3 Each shipment manifest shall include a certification by the waste generator as specified in
Section II of Appendix 4D.
4.38.4 Each person involved in the transfer of waste for disposal or in the disposal of waste, including
the waste generator, waste collector, waste processor, and disposal facility operator, shall comply
with the requirements specified in Section III of Appendix 4D.
4.38.5 Any licensee shipping byproduct material as defined in paragraphs (3) and (4) of the definition of
Byproduct material set forth in 1.2. intended for ultimate disposal at a land disposal facility
licensed under 10 CFR Part 61, must document the information required on the NRC’s Uniform
Low-Level Radioactive Waste Manifest and transfer this recorded manifest information to the
intended consignee in accordance with Appendix 4D.
4.39
Additional Disposal Requirements
4.39.1 Compliance with Environmental and Health Protection Regulations.
Hazardous Materials and Waste Management
29
4.39.1.1
Nothing in 4.33, 4.34, 4.35, 4.37, 4.38 or 4.39.2 relieves the licensee or registrant
from complying with other applicable Federal, State and local regulations governing any
other toxic or hazardous properties of materials that may be disposed of pursuant to 4.33,
4.34, 4.35, 4.37, 4.38, or 4.39.2.
4.39.2 Disposal of Certain Byproduct Material
4.39.2.1
Licensed material as defined in paragraphs (3) and (4) of the definition of
Byproduct material set forth in Part 1, Section 1.2 may be disposed of in accordance with
Part 14 or equivalent regulations of NRC or an Agreement State, even though it is not
defined as low-level radioactive waste. Therefore, any licensed material being disposed
of at a facility, or transferred for ultimate disposal at a facility licensed under Part 14, or
equivalent regulations of NRC or Agreement State, must meet the requirements of 4.38.
4.39.2.2
A licensee may dispose of byproduct material, as defined in paragraphs (3) and
(4) of the definition of Byproduct material set forth in Part 1, Section 1.2, at a disposal
facility authorized to dispose of such material in accordance with any Federal or State
solid or hazardous waste law, including the Solid Waste Disposal Act, as authorized
under the Energy Policy Act of 2005.
RECORDS
4.40
General Provisions.
4.40.1 Each person who receives source or radioactive material pursuant to a license issued pursuant to
Part 3 shall keep records showing the receipt, transfer, and disposal of this radioactive material
as follows:
4.40.1.1
The licensee shall retain each record of receipt of source or radioactive material
as long as the material is possessed and for three years following transfer or disposition
of the radioactive material.
4.40.1.2
The licensee who transferred the material shall retain each record of transfer of
source or radioactive material until the Department terminates each license that
authorizes the activity that is subject to the recordkeeping requirement.
4.40.1.3
The licensee shall retain each record of disposal of source or radioactive material
until the Department terminates each license that authorizes the activity that is subject to
the recordkeeping requirement.
4.40.1.4
If source or radioactive material is combined or mixed with other licensed
material and subsequently treated in a manner that makes direct correlation of a receipt
record with a transfer, export, or disposition record impossible, the licensee may use
evaluative techniques (such as first-in-first-out), to make the records that are required by
Part 4 account for 100 percent of the material received.
4.40.2 The licensee shall retain each record that is required by the regulations in this part or by license
condition for the period specified by the appropriate regulation or license condition. If a retention
period is not otherwise specified by regulation or license condition, each record must be
maintained until the Department terminates the license that authorizes the activity that is subject
to the recordkeeping requirement.
4.40.3 Each licensee or registrant shall use the SI units becquerel, gray, sievert and coulomb per
kilogram, or the special units curie, rad, rem and roentgen, including multiples and subdivisions,
and shall clearly indicate the units of all quantities on records required by Part 4.
Hazardous Materials and Waste Management
30
4.40.4 The licensee or registrant shall make a clear distinction among the quantities entered on the
records required by Part 4 (e.g., total effective dose equivalent, total organ dose equivalent,
shallow dose equivalent, lens dose equivalent, deep dose equivalent, committed effective dose
equivalent).
4.40.5 The licensee or registrant shall be consistent in their use of SI or special units. The licensee or
registrant shall not change the units used on records required by Part 4 except at the beginning of
the calendar year or with Department approval.
4.41
Records of Radiation Protection Programs.
4.41.1 Each licensee or registrant shall maintain records of the radiation protection program, including:
4.41.1.1
The provisions of the program; and
4.41.1.2
Audits and other reviews of program content and implementation.
4.41.2 The licensee or registrant shall retain the records required by 4.41.1.1 until the Department
terminates each pertinent license or registration requiring the record. The licensee or registrant
shall retain the records required by 4.41.1.2 for 3 years after the record is made.
4.42
Records of Surveys.
4.42.1 Each licensee or registrant shall maintain records showing the results of surveys and calibrations
required by 4.17 and 4.32.2. The licensee or registrant shall retain these records for 3 years after
the record is made.
4.42.2 The licensee or registrant shall retain each of the following records until the Department
terminates each pertinent license or registration requiring the record:
4.42.2.1
Records of the results of surveys to determine the dose from external sources of
radiation and used, in the absence of or in combination with individual monitoring data, in
the assessment of individual dose equivalents; and
4.42.2.2
Records of the results of measurements and calculations used to determine
individual intakes of radioactive material and used in the assessment of internal dose;
and
4.42.2.3
Records showing the results of air sampling, surveys, and bioassays required
pursuant to 4.24.1.3(1) and 4.24.1.3(2); and
4.42.2.4
Records of the results of measurements and calculations used to evaluate the
release of radioactive effluents to the environment.
4.42.3 Upon termination of the license or registration, the licensee or registrant shall permanently store
records on Department Form R-16 or equivalent, or shall make provision with the Department for
transfer to the Department.
4.43
Records of Tests for Leakage or Contamination of Sealed Sources.
Records of tests for leakage or contamination of sealed sources required by 4.16 shall be kept in
units of becquerel (or microcurie) and maintained for inspection by the Department for 5 years
after the records are made.
Hazardous Materials and Waste Management
31
4.44
Records of Prior Occupational Dose.
4.44.1 The licensee or registrant shall retain the records of prior occupational dose and exposure history
as specified in 4.10 on Department Form R-16 or equivalent until the Department terminates each
pertinent license or registration requiring this record. The licensee or registrant shall retain
records used in preparing Department Form R-16 or equivalent for 3 years after the record is
made.
4.44.2 Upon termination of the license or registration, the licensee or registrant shall permanently store
records on Department Form R-16 or equivalent, or shall make provision with the Department for
transfer to the Department.
4.45
Records of Planned Special Exposures.
4.45.1 For each use of the provisions of 4.11 for planned special exposures, the licensee or registrant
shall maintain records that describe:
4.45.1.1
The exceptional circumstances requiring the use of a planned special exposure;
and
4.45.1.2
The name of the management official who authorized the planned special
exposure and a copy of the signed authorization; and
4.45.1.3
What actions were necessary; and
4.45.1.4
Why the actions were necessary; and
4.45.1.5
What precautions were taken to assure that doses were maintained ALARA; and
4.45.1.6
What individual and collective doses were expected to result; and
4.45.1.7
The doses actually received in the planned special exposure.
4.45.2 The licensee or registrant shall retain the records until the Department terminates each pertinent
license or registration requiring these records.
4.45.3 Upon termination of the license or registration, the licensee or registrant shall permanently store
records on Department Form R-16 or equivalent, or shall make provision with the Department for
transfer to the Department.
4.46
Records of Individual Monitoring Results.
4.46.1 Recordkeeping Requirement. Each licensee or registrant shall maintain records of doses
received by all individuals for whom monitoring was required pursuant to 4.18, and records of
doses received during planned special exposures, accidents, and emergency conditions.
Assessments of dose equivalent and records made using units in effect before January 1, 1994
need not be changed. These records shall include, when applicable:
4.46.1.1
The deep dose equivalent to the whole body, lens dose equivalent, shallow dose
equivalent to the skin, and shallow dose equivalent to the extremities;
4.46.1.2
The estimated intake of radionuclides (see 4.7);
4.46.1.3
The committed effective dose equivalent assigned to the intake of radionuclides;
Hazardous Materials and Waste Management
32
4.46.1.4
The specific information used to assess and calculate the committed effective
dose equivalent pursuant to 4.9.1 and 4.9.3, and when required by 4.18;
4.46.1.5
The total effective dose equivalent when required by 4.7; and
4.46.1.6
The total of the deep dose equivalent and the committed dose to the organ
receiving the highest total dose.
4.46.2 Recordkeeping Frequency.
The licensee or registrant shall make entries of the records specified in 4.46.1 at intervals not to
exceed 1 year.
4.46.3 Recordkeeping Format.
The licensee or registrant shall maintain the records specified in 4.46.1 on Department Form R-
17, Occupational Exposure Record for a Monitoring Period, in accordance with the instructions for
Department Form R-17, or in clear and legible records containing all the information required by
Department Form R-17.
4.46.4 The licensee or registrant shall maintain the records of dose to an embryo/fetus with the records
of dose to the declared pregnant woman. The declaration of pregnancy, including the estimated
date of conception, shall also be kept on file, but may be maintained separately from the dose
records.
4.46.5 The licensee or registrant shall retain each required form or record until the Department
terminates each pertinent license or registration requiring the record.
4.46.6 Upon termination of the license or registration, the licensee or registrant shall permanently store
records on Department Form R-16 or equivalent, or shall make provision with the Department for
transfer to the Department.
4.47
Records of Dose to Individual Members of the Public.
4.47.1 Each licensee or registrant shall maintain records sufficient to demonstrate compliance with the
dose limit for individual members of the public. See 4.14.
4.47.2 The licensee or registrant shall retain the records required by 4.47.1 until the Department
terminates each pertinent license or registration requiring the record.
4.48
Records of Waste Disposal.
4.48.1 Each licensee or registrant shall maintain records of the disposal of licensed or registered
materials made pursuant to 4.34, 4.35, 4.36, 4.37, Part 14 of these regulations, and disposal by
burial in soil, including burials authorized before December 30, 1985.
4.48.2 The licensee or registrant shall retain the records required by 4.48.1 in accordance with 3.15.4
until the Department terminates each pertinent license or registration requiring the record.
4.48.3 For radioactive material disposed in accordance with 4.33.1.2, the licensee shall retain a record
of each decay in storage disposal for 3 years. The record must include the date of the disposal,
the survey instrument used, the background radiation level, the radiation level measured at the
surface of each waste container, and the name of the individual who performed the survey.
Hazardous Materials and Waste Management
33
4.49
Records of Testing Entry Control Devices for Very High Radiation Areas.
4.49.1 Each licensee or registrant shall maintain records of tests made pursuant to 4.21.2.9 on entry
control devices for very high radiation areas. These records must include the date, time, and
results of each such test of function.
4.49.2 The licensee or registrant shall retain the records required by 4.49.1 for 3 years after the record is
made.
4.50
Form of Records.
Each record required by Part 4 shall be legible throughout the specified retention period. The
record shall be the original or a reproduced copy or a microform, provided that the copy or
microform is authenticated by authorized personnel and that the microform is capable of
producing a clear copy throughout the required retention period or the record may also be stored
in Department-approved electronic media with the capability for producing legible, accurate, and
complete records during the required retention period. Records, such as letters, drawings, and
specifications, shall include all pertinent information, such as stamps, initials, and signatures. The
licensee shall maintain adequate safeguards against tampering with and loss of records.
REPORTS
4.51
Reports of Stolen, Lost, or Missing Licensed or Registered Sources of Radiation.
4.51.1 Telephone Reports.
Each licensee or registrant shall report to the Department by telephone as follows:
4.51.1.1
Immediately after its occurrence becomes known to the licensee or registrant,
stolen, lost, or missing licensed or registered radioactive material in an aggregate
quantity equal to or greater than 1,000 times the quantity specified in Appendix 4C under
such circumstances that it appears to the licensee or registrant that an exposure could
result to individuals in unrestricted areas; or
4.51.1.2
Within 30 days after its occurrence becomes known to the licensee or registrant,
lost, stolen, or missing licensed or registered radioactive material in an aggregate
quantity greater than 10 times the quantity specified in Appendix 4C that is still missing.
4.51.1.3
Immediately after its occurrence becomes known to the registrant, a stolen, lost,
or missing radiation machine.
4.51.2 Written Reports.
Each licensee or registrant required to make a report pursuant to 4.51.1 shall, within 30 days after
making the telephone report, make a written report to the Department setting forth the following
information:
4.51.2.1
A description of the licensed or registered source of radiation involved, including,
for radioactive material, the kind, quantity, and chemical and physical form; and, for
radiation machines, the manufacturer, model and serial number, type and maximum
energy of radiation emitted;
4.51.2.2
A description of the circumstances under which the loss or theft occurred; and
Hazardous Materials and Waste Management
34
4.51.2.3
A statement of disposition, or probable disposition, of the licensed or registered
source of radiation involved; and
4.51.2.4
Exposures of individuals to radiation, circumstances under which the exposures
occurred, and the possible total effective dose equivalent to persons in unrestricted
areas; and
4.51.2.5
Actions that have been taken, or will be taken, to recover the source of radiation;
and
4.51.2.6
Procedures or measures that have been, or will be, adopted to ensure against a
recurrence of the loss or theft of licensed or registered sources of radiation.
4.51.3 Subsequent to filing the written report, the licensee or registrant shall also report additional
substantive information on the loss or theft within 30 days after the licensee or registrant learns of
such information.
4.51.4 The licensee or registrant shall prepare any report filed with the Department pursuant to 4.51 so
that names of individuals who may have received exposure to radiation are stated in a separate
and detachable portion of the report.
4.52
Notification of Incidents.
4.52.1 Immediate Notification.
Notwithstanding other requirements for notification, each licensee or registrant shall notify the
Department as soon as possible but not later than 4 hours after the discovery of an event:
4.52.1.1
Involving a source of radiation possessed by the licensee or registrant that may
have caused or threatens to cause any of the following conditions:
(1)
An individual to receive:
(a)
A total effective dose equivalent of 0.25 Sv (25 rem) or more; or
(b)
A lens dose equivalent of 0.75 Sv (75 rem) or more; or
(c)
A shallow dose equivalent to the skin or extremities or a total organ dose
equivalent of 2.5 Gy (250 rad) or more; or
(2)
The release of radioactive material, inside or outside of a restricted area, so that,
had an individual been present for 24 hours, the individual could have received
an intake five times the occupational ALI. This provision does not apply to
locations where personnel are not normally stationed during routine operations,
such as hot cells or process enclosures.
4.52.1.2
That prevents immediate protective actions necessary to avoid exposures to
radiation and/or radioactive materials that could exceed regulatory limits, or releases of
licensed material that could exceed regulatory limits (events may include fires,
explosions, toxic gas releases, etc.).
4.52.2 Twenty-Four Hour Notification.
Each licensee or registrant shall, within 24 hours of discovery of the event, report to the
Department:
Hazardous Materials and Waste Management
35
4.52.2.1
Each event involving loss of control of a licensed or registered source of radiation
possessed by the licensee or registrant that may have caused, or threatens to cause, any
of the following conditions:
(1)
An individual to receive, in a period of 24 hours:
(a)
A total effective dose equivalent exceeding 0.05 Sv (5 rem); or
(b)
A lens dose equivalent exceeding 0.15 Sv (15 rem); or
(c)
A shallow dose equivalent to the skin or extremities or a total organ dose
equivalent exceeding 0.5 Sv (50 rem); or
(2)
The release of radioactive material, inside or outside of a restricted area, so that,
had an individual been present for 24 hours, the individual could have received
an intake in excess of one occupational ALI. This provision does not apply to
locations where personnel are not normally stationed during routine operations,
such as hot-cells or process enclosures.
4.52.2.2
An unplanned contamination event that:
(1)
Requires access to the contaminated area, by workers or the public, to be
restricted for more than 24 hours by imposing additional radiological controls or
by prohibiting entry into the area;
(2)
Involves a quantity of material greater than five times the lowest annual limit on
intake specified in Appendix 4B for the material; and
(3)
Has access to the area restricted for a reason other than to allow isotopes with a
half-life of less than 24 hours to decay prior to decontamination.
4.52.2.3
An event in which equipment is disabled or fails to function as designed when:
(1)
The equipment is required by regulation or license condition to prevent releases
exceeding regulatory limits, to prevent exposures to radiation and/or radioactive
materials exceeding regulatory limits, or to mitigate the consequences of an
accident; and
(2)
The equipment is required to be available and operable when it is disabled or
fails to function during the event; and
(3)
No redundant equipment is available and operable to perform the required safety
function.
4.52.2.4
An event that requires unplanned medical treatment at a medical facility of an
individual whose body or clothing is contaminated with spreadable radioactive material.
4.52.2.5
An unplanned fire or explosion damaging any licensed material or any device,
container, or equipment containing licensed material when:
(1)
The quantity of material involved is greater than five times the lowest annual limit
on intake specified in Appendix 4B for the material; and
(2)
The damage affects the integrity of the licensed material or its container.
Hazardous Materials and Waste Management
36
4.53
Preparation and Submission of Reports.
4.53.1 Reports made by licensees or registrants in response to the requirements of 4.52, must be made
as follows:
4.53.1.1
Licensees or registrants shall make the reports required by 4.52.1 and 4.52.2 to
the Department by telephone. To the extent that the information is available at the time of
notification, the information provided in these reports must include:
(1)
The caller's name and call back telephone number;
(2)
A description of the event including date and time;
(3)
The exact location of the event;
(4)
The isotopes, quantities, and chemical and physical form of the licensed material
involved; and
(5)
Any personnel radiation exposure data available.
4.53.1.2
Each licensee or registrant who makes a report required by 4.52.1 or 4.52.2 shall
submit a written follow-up report to the Department pursuant to 4.53.3 within 30 days of
the initial report. Written reports prepared pursuant to other regulations may be submitted
to fulfill this requirement if the reports contain all of the necessary information and the
appropriate distribution is made.
4.53.1.3
The provisions of 4.52 do not apply to doses that result from planned special
exposures, provided such doses are within the limits for planned special exposures and
are reported pursuant to 4.54.
4.53.2 Reports of Exposures, Radiation Levels, and Concentrations of Radioactive Material Exceeding
the Constraints or Limits.
In addition to the notification required by 4.52, each licensee or registrant shall submit a written
report to the Department within 30 days after learning of any of the following occurrences:
4.53.2.1
Incidents for which notification is required by 4.52; or
4.53.2.2
Doses in excess of any of the following:
(1)
The occupational dose limits for adults in 4.6; or
(2)
The occupational dose limits for a minor in 4.12; or
(3)
The limits for an embryo/fetus of a declared pregnant woman in 4.13; or
(4)
The limits for an individual member of the public in 4.14; or
(5)
Any applicable limit in the license or registration; or
(6)
The ALARA constraints for air emissions established under 4.5.4.
4.53.2.3
Levels of radiation or concentrations of radioactive material in:
(1)
A restricted area in excess of applicable limits in the license or registration; or
Hazardous Materials and Waste Management
37
(2)
An unrestricted area in excess of 10 times the applicable limit set forth in Part 4
or in the license or registration, whether or not involving exposure of any
individual in excess of the limits in 4.14; or
4.53.2.4
For licensees subject to the provisions of U.S. Environmental Protection
Agency's generally applicable environmental radiation standards in 40 CFR 190, July 1,
2004, levels of radiation or releases of radioactive material in excess of those standards,
or of license conditions related to those standards.
4.53.3 Contents of Written Reports.
4.53.3.1
Each report required by 4.53.1.2 or 4.53.2 shall include the following, as
appropriate:
(1)
A description of the event, including the possible cause and the manufacturer
and model number (if applicable) of any equipment that failed or malfunctioned;
(2)
The exact location of the event;
(3)
The isotopes, quantities, and chemical and physical form of the licensed material
involved;
(4)
Date and time of the event;
(5)
The results of any evaluations or assessments, including:
(a)
Estimates of each individual's dose;
(b)
The levels of radiation and concentrations of radioactive material
involved;
(c)
The cause of the elevated exposures, dose rates, or concentrations; and
(d)
Corrective steps taken or planned to ensure against a recurrence,
including the schedule for achieving conformance with applicable limits,
ALARA constraints, generally applicable environmental standards, and
associated license or registration conditions.
4.53.3.2
Each report filed pursuant to 4.53 shall include for each occupationally
overexposed individual exposed: the name, Social Security account number, and date of
birth. With respect to the limit for the embryo/fetus in 4.13, the identifiers should be those
of the declared pregnant woman. The report shall be prepared so that this information is
stated in a separate and detachable portion of the report and must be clearly labeled
“Privacy Act Information: Not for Public Disclosure”.
4.54
Reports of Planned Special Exposures.
4.54.1 The licensee or registrant shall submit a written report to the Department within 30 days following
any planned special exposure conducted in accordance with 4.11, informing the Department that
a planned special exposure was conducted and indicating the date the planned special exposure
occurred and the information required by 4.45.
Hazardous Materials and Waste Management
38
4.55
Reports of Transactions Involving Nationally Tracked Sources.
4.55.1 Each licensee who manufactures, transfers, receives, disassembles, or disposes of a nationally
tracked source shall complete and submit a National Source Tracking Transaction Report as
specified in 4.55.1.1 through 4.55.1.5 for each type of transaction.
4.55.1.1
Each licensee who manufactures a nationally tracked source shall complete and
submit a National Source Tracking Report. The report must include the following
information:
(1)
The name, address, and license number of the reporting licensee;
(2)
The name of the individual preparing the report;
(3)
The manufacturer, model, and serial number of the source;
(4)
The radioactive material in the source;
(5)
The initial source strength in becquerels (curies) at the time of manufacture;
and
(6)
The manufacture date of the source.
4.55.1.2
Each licensee that transfers a nationally tracked source to another person shall
complete and submit a National Source Tracking Transaction Report. The report must
include the following information:
(1)
The name, address, and license number of the reporting licensee;
(2)
The name of the individual preparing the report;
(3)
The name and license number of the recipient facility and the shipping address;
(4)
The manufacturer, model, and serial number of the source or, if not available,
other information to uniquely identify the source;
(5)
The radioactive material in the source;
(6)
The initial or current source strength in becquerels (curies);
(7)
The date for which the source strength is reported;
(8)
The shipping date;
(9)
The estimated arrival date;
and
(10)
For nationally tracked sources transferred as waste under a Uniform Low-Level
Radioactive Waste Manifest, the waste manifest number and the container
identification of the container with the nationally tracked source.
Hazardous Materials and Waste Management
39
4.55.1.3
Each licensee that receives a nationally tracked source shall complete and
submit a National Source Tracking Transaction Report. The report must include the
following information:
(1)
The name, address, and license number of the reporting licensee;
(2)
The name of the individual preparing the report;
(3)
The name, address, and license number of the person that provided the source;
(4)
The manufacturer, model, and serial number of the source or, if not available,
other information to uniquely identify the source;
(5)
The radioactive material in the source;
(6)
The initial or current source strength in becquerels (curies);
(7)
The date for which the source strength is reported;
(8)
The date of receipt;
and
(9)
For material received under a Uniform Low-Level Radioactive Waste Manifest,
the waste manifest number and the container identification with the nationally
tracked source.
4.55.1.4
Each licensee that disassembles a nationally tracked source shall complete and
submit a National Source Tracking Transaction Report. The report must include the
following information:
(1)
The name, address, and license number of the reporting licensee;
(2)
The name of the individual preparing the report;
(3)
The manufacturer, model, and serial number of the source or, if not available,
other information to uniquely identify the source;
(4)
The radioactive material in the source;
(5)
The initial or current source strength in becquerels (curies);
(6)
The date for which the source strength is reported;
(7)
The disassemble date of the source.
4.55.1.5
Each licensee who disposes of a nationally tracked source shall complete and
submit a National Source Tracking Transaction Report. The report must include the
following information:
(1)
The name, address, and license number of the reporting licensee;
(2)
The name of the individual preparing the report;
(3)
The waste manifest number;
Hazardous Materials and Waste Management
40
(4)
The container identification with the nationally tracked source.
(5)
The date of disposal;
and
(6)
The method of disposal.
4.55.1.6
The reports discussed in 4.55.1.1 through 4.55.1.5 must be submitted by the
close of the next business day after the transaction. A single report may be submitted for
multiple sources and transactions. The reports must be submitted to the National Source
Tracking System by using:
(1)
The on-line National Source Tracking System;
(2)
Electronically using a computer readable format;
(3)
By facsimile;
(4)
By mail to the address on the National Source Tracking Transaction Report Form
(NRC Form 748); or
(5)
By telephone with followup by facsimile or mail.
4.55.2 Each licensee shall correct any error in previously filed reports or file a new report for any missed
transaction within 5 business days of the discovery of the error or missed transaction. Such errors
may be detected by a variety of methods such as administrative reviews or by physical
inventories required by regulation. In addition, each licensee shall reconcile the inventory of
nationally tracked sources possessed by the licensee against that licensee’s data in the National
Source Tracking System. The reconciliation must be conducted during the month of January in
each year. The reconciliation process must include resolving any discrepancies between the
National Source Tracking System and the actual inventory by filing the reports identified by
4.55.1.1 through 4.55.1.5. By January 31 of each year, each licensee must submit to the National
Source Tracking System confirmation that the data in the National Source Tracking System is
correct.
4.56
Reports of Individual Monitoring.
4.56.1 This section applies to each person licensed or registered by the Department to:
4.56.1.1
Possess or use sources of radiation for purposes of industrial radiography
pursuant to Parts 3 and 5 of these regulations; or
4.56.1.2
Receive radioactive waste from other persons for disposal pursuant to Part 14 of
these regulations; or
4.56.1.3
Possess or use at any time, for processing or manufacturing for distribution
pursuant to Part 3 or 7 of these regulations, radioactive material in quantities exceeding
any one of the following quantities:
Hazardous Materials and Waste Management
41
Radionuclide
Activity
7
Activity
7

Ci
GBq
Cesium-137
1
37
Cobalt-60
1
37
Gold-198
100
3,700
Iodine-131
1
37
Iridium-192
10
370
Krypton-85
1,000
37,000
Promethium-147
10
370
Technetium-99m
1,000
37,000
7 The Department may require as a license condition, or by rule, regulation, or order pursuant to 1.9, reports from licensees or
registrants who are licensed or registered to use radionuclides not on this list, in quantities sufficient to cause comparable radiation
levels.
4.56.2 Each licensee or registrant in a category listed in 4.56.1 shall submit an annual report to the
Department of the results of individual monitoring carried out by the licensee or registrant for each
individual for whom monitoring was required by 4.18 during that year. The licensee or registrant
may include additional data for individuals for whom monitoring was provided but not required.
The licensee or registrant shall use Department Form R-17 or equivalent or Department-
approved electronic media containing all the information required by Department Form R-17.
4.56.3 The licensee or registrant shall file the report required by 4.56.2, covering the preceding year, on
or before April 30 of each year.
4.57
Notifications and Reports to Individuals.
4.57.1 Requirements for notification and reports to individuals of exposure to radiation or radioactive
material are specified in 10.4 of these regulations.
4.57.2 When a licensee or registrant is required pursuant to 4.53.2 or 4.54 to report to the Department
any exposure of an identified occupationally exposed individual or an identified member of the
public, to radiation or radioactive material, the licensee or registrant shall also provide the
individual a report on his or her exposure data included in the report to the Department. Such
report shall be transmitted at a time not later than the transmittal to the Department, and shall
comply with the provisions of 10.4.1 of these regulations.
4.58
Reports of Leaking or Contaminated Sealed Sources.
4.58.1 The licensee or registrant shall file a report within 5 days with the Department if the test for
leakage or contamination indicates a sealed source is leaking or contaminated. The report shall
include the equipment involved, the test results and the corrective action taken.
ADDITIONAL REQUIREMENTS
4.59
Vacating Premises.
4.59.1 Each specific licensee or registrant shall, no less than 30 days before vacating or relinquishing
possession or control of premises which may have been contaminated with radioactive material
as a result of the licensee's or registrant's activities, notify the Department in writing of intent to
vacate. When deemed necessary by the Department, the licensee shall decontaminate the
premises in such a manner as the Department may specify.
Hazardous Materials and Waste Management
42
4.60
Permissible Levels of Radioactive Material in Uncontrolled Areas.
4.60.1 Plutonium. Contamination of the soil in excess of 2.0 disintegrations per minute (0.03 Bq) of
plutonium per gram of dry soil or square centimeter of surface area (0.01 microcurie [370 Bq] per
square meter) presents a sufficient hazard to the public health to require the utilization of special
techniques of construction upon property so contaminated. Evaluation of proposed control
techniques shall be available from the Department upon request.
4.61
Radiological Criteria For License Termination.
4.61.1 The criteria in this section apply to the decommissioning of facilities licensed under Parts 3, 5, 7,
14, 16, and 19 of these regulations. For low-level waste disposal facilities licensed under Part 14,
the criteria apply only to the ancillary surface facilities that support radioactive waste disposal
activities.
4.61.1.1
The criteria in this section do not apply to uranium and thorium recovery facilities
already subject to Appendix A of Part 18; uranium solution extraction facilities; sites
which have been decommissioned and the license terminated prior to July 1, 1999; or
sites which submitted a decommissioning plan prior to July 1, 2000 and received
Department approval of that decommissioning plan prior to July 1, 2001.
4.61.1.2
When calculating the TEDE to the average member of the critical group, the
licensee shall determine the peak annual TEDE expected within the first 1000 years after
decommissioning. In accordance with 1.5.1, the Department may authorize the licensee
to exclude dose contributions from the inhalation of radon and its decay products when
calculating TEDE.
4.61.1.3
Determination of dose and residual radioactivity levels which are as low as
reasonably achievable (ALARA) must take into account consideration of any detriments,
such as deaths from transportation accidents, expected to potentially result from
decontamination and waste disposal.
4.61.2 Radiological Criteria For Unrestricted Use.
A site will be considered acceptable for license termination under conditions of unrestricted use if
the residual radioactivity that is distinguishable from background radiation results in a TEDE to an
average member of the critical group that does not exceed 0.25 mSv per year (25 mrem/y),
including that from groundwater sources of drinking water, and the residual radioactivity has been
reduced to levels that are ALARA.
4.61.3 Radiological Criteria For Restricted Use.
A site will be considered acceptable for license termination under restricted conditions if:
4.61.3.1
The licensee can demonstrate that further reductions in residual radioactivity
necessary to comply with the provisions of 4.61.2 would result in net public or
environmental harm or were not being made because the residual levels of contamination
associated with restricted conditions are ALARA. Determination of the levels which are
ALARA must take into consideration any detriments, such as traffic accidents, expected
to potentially result from decontamination and waste disposal;
4.61.3.2
The licensee has made provisions for durable, legally enforceable institutional
controls which provide reasonable assurance that the TEDE from residual radioactivity
distinguishable from background to the average member of the critical group will not
exceed 0.25 mSv per year (25 mrem/y).
Hazardous Materials and Waste Management
43
4.61.3.3
The licensee has provided sufficient financial assurance to enable an
independent third party, including a governmental custodian of a site, to assume and
carry out responsibilities for any necessary control and maintenance of the site.
Acceptable financial assurance mechanisms are:
(1)
Funds placed into an account segregated from the licensee’s assets and outside
the licensee’s administrative control as described in Part 3, Section 3.9.5.4(2)(a);
(2)
In the case of Federal, State, or local Government licensees, a statement of
intent containing a cost estimate for decommissioning and indicating that funds
for decommissioning will be obtained when necessary; or
(3)
When a governmental entity is assuming custody and ownership of a site, an
arrangement that is deemed acceptable by such governmental entity; and
4.61.3.4
Residual radioactivity at the site has been reduced so that if the institutional
controls were no longer in effect, there is reasonable assurance that the TEDE from
residual radioactivity distinguishable from background to the average member of the
critical group is ALARA and would not exceed either:
(1)
1 mSv per year (100 mrem/y); or
(2)
5 mSv per year (500 mrem/y), provided the licensee:
(a)
demonstrates that further reductions in residual radioactivity necessary
to comply with the 1-mSv-per-year (100 mrem/y) value of this paragraph
are not technically achievable, would be prohibitively expensive, or would
result in net public or environmental harm.
4.61.4 Alternate Criteria For License Termination.
4.61.4.1
The Department may terminate a license using alternate criteria greater than the
dose criterion of 4.61.2 or 4.61.3.2, if:
(1)
The licensee has performed an analysis for possible sources of exposure to
radiation which provides assurance that public health and safety would continue
to be protected, and that it is unlikely the TEDE to an average member of the
critical group from all radiation that is distinguishable from background radiation,
other than medical, would be more than 1 mSv per year (100 mrem/y);
(2)
The licensee has employed, to the extent practical, restrictions on site use which
minimize exposures at the site in accordance with the provisions of 4.61.3;
(3)
The licensee has reduced doses to levels which are ALARA; and
(4)
Has provided sufficient financial assurance in the form of a trust fund to enable
an independent third party, including a governmental custodian of a site, to
assume and carry out responsibilities for any necessary control and maintenance
of the site.
Hazardous Materials and Waste Management
44
PART 4, APPENDIX 4A:
ASSIGNED PROTECTION FACTORS FOR RESPIRATORS

Operating Mode
Assigned
Protection
Factors
I. Air purifying respirators [particulateb only]c:

Filtering facepiece disposable
Negative pressure
(d)
Facepiece, halfe
Negative pressure
10
Facepiece, full
Negative pressure
100
Facepiece, half
Powered air-purifying respirators
50
Facepiece, full
Powered air-purifying respirators
1000
Helmet/hood
Powered air-purifying respirators
1000
Facepiece, loose-fitting
Powered air-purifying respirators
25
II. Atmosphere supplying respirators
[particulate, gases and vaporsf]:

1. Air-line respirator:

Facepiece, half
Demand
10
Facepiece, half
Continuous flow
50
Facepiece, half
Pressure demand
50
Facepiece, full
Demand
100
Facepiece, full
Continuous flow
1000
Facepiece, full
Pressure demand
1000
Helmet/hood
Continuous flow
1000
Facepiece, loose-fitting
Continuous flow
25
Suit
Continuous flow
(g)
2. Self-contained breathing apparatus
(SCBA):

Facepiece, full
Demand
h 100
Facepiece, full
Pressure dem

[Text truncated at 120,000 characters. The full text is on the page linked above.]

## Nearby sections

- [6 CCR 1007-1 RADIATION CONTROL – (Rule Versions Prior to 04/01/2007)](https://www.frixlaw.com/law-library/statutes/STATE_CO_CCR_6_CCR_1007_1.md)
- [6 CCR 1007-1 Part 01 RADIATION CONTROL - GENERAL PROVISIONS](https://www.frixlaw.com/law-library/statutes/STATE_CO_CCR_6_CCR_1007_1_Part_01.md)
- [6 CCR 1007-1 Part 02 RADIATION CONTROL - REGISTRATION OF RADIATION MACHINES, FACILITIES AND SERVICES](https://www.frixlaw.com/law-library/statutes/STATE_CO_CCR_6_CCR_1007_1_Part_02.md)
- [6 CCR 1007-1 Part 03 RADIATION CONTROL - LICENSING OF RADIOACTIVE MATERIAL](https://www.frixlaw.com/law-library/statutes/STATE_CO_CCR_6_CCR_1007_1_Part_03.md)
- [6 CCR 1007-1 Part 04 RADIATION CONTROL - STANDARDS FOR PROTECTION AGAINST RADIATION](https://www.frixlaw.com/law-library/statutes/STATE_CO_CCR_6_CCR_1007_1_Part_04.md)
- [6 CCR 1007-1 Part 05 RADIATION CONTROL - RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS](https://www.frixlaw.com/law-library/statutes/STATE_CO_CCR_6_CCR_1007_1_Part_05.md)
- [6 CCR 1007-1 Part 06 RADIATION CONTROL - X-RAY IMAGING IN THE HEALING ARTS](https://www.frixlaw.com/law-library/statutes/STATE_CO_CCR_6_CCR_1007_1_Part_06.md)
- [6 CCR 1007-1 Part 07 RADIATION CONTROL - USE OF RADIONUCLIDES IN THE HEALING ARTS](https://www.frixlaw.com/law-library/statutes/STATE_CO_CCR_6_CCR_1007_1_Part_07.md)
- [6 CCR 1007-1 Part 08 RADIATION CONTROL - RADIATION SAFETY REQUIREMENTS FOR RADIATION GENERATING DEVICES NOT USED IN THE HEALING ARTS](https://www.frixlaw.com/law-library/statutes/STATE_CO_CCR_6_CCR_1007_1_Part_08.md)
- [6 CCR 1007-1 Part 09 RADIATION CONTROL - RADIATION SAFETY REQUIREMENTS FOR PARTICLE ACCELERATORS NOT USED IN THE HEALING ARTS](https://www.frixlaw.com/law-library/statutes/STATE_CO_CCR_6_CCR_1007_1_Part_09.md)
- [6 CCR 1007-1 Part 10 RADIATION CONTROL - NOTICES, INSTRUCTIONS, AND REPORTS TO WORKERS: INSPECTIONS](https://www.frixlaw.com/law-library/statutes/STATE_CO_CCR_6_CCR_1007_1_Part_10.md)
- [6 CCR 1007-1 Part 11 RADIATION CONTROL - SPECIAL LAND OWNERSHIP REQUIREMENTS GENERAL PROVISIONS](https://www.frixlaw.com/law-library/statutes/STATE_CO_CCR_6_CCR_1007_1_Part_11.md)
- [6 CCR 1007-1 Part 12 RADIATION CONTROL - FEES FOR RADIATION CONTROL SERVICES](https://www.frixlaw.com/law-library/statutes/STATE_CO_CCR_6_CCR_1007_1_Part_12.md)
- [6 CCR 1007-1 Part 13 RADIATION CONTROL - COMPLIANCE ENFORCEMENT](https://www.frixlaw.com/law-library/statutes/STATE_CO_CCR_6_CCR_1007_1_Part_13.md)

---

Source: Frix Law Library, https://www.frixlaw.com/law-library/statutes/STATE_CO_CCR_6_CCR_1007_1_Part_04. Check the current official text before relying on it. Not legal advice.