## Text

(a) The special factors prescribed in §§ 27.621 through 27.625 apply to each part of the structure whose strength is—
(1) Uncertain;
(2) Likely to deteriorate in service before normal replacement; or
(3) Subject to appreciable variability due to—
(i) Uncertainties in manufacturing processes; or
(ii) Uncertainties in inspection methods.
(b) For each part to which §§ 27.621 through 27.625 apply, the factor of safety prescribed in § 27.303 must be multiplied by a special factor equal to—
(1) The applicable special factors prescribed in §§ 27.621 through 27.625; or
(2) Any other factor great enough to ensure that the probability of the part being understrength because of the uncertainties specified in paragraph (a) of this section is extremely remote.

## Nearby sections

- [14 C.F.R. § 27.601 (2026) § 27.601   Design.](https://www.frixlaw.com/law-library/statutes/CFR_T14_P27_S27_601.md)
- [14 C.F.R. § 27.602 (2026) § 27.602   Critical parts.](https://www.frixlaw.com/law-library/statutes/CFR_T14_P27_S27_602.md)
- [14 C.F.R. § 27.603 (2026) § 27.603   Materials.](https://www.frixlaw.com/law-library/statutes/CFR_T14_P27_S27_603.md)
- [14 C.F.R. § 27.605 (2026) § 27.605   Fabrication methods.](https://www.frixlaw.com/law-library/statutes/CFR_T14_P27_S27_605.md)
- [14 C.F.R. § 27.607 (2026) § 27.607   Fasteners.](https://www.frixlaw.com/law-library/statutes/CFR_T14_P27_S27_607.md)
- [14 C.F.R. § 27.609 (2026) § 27.609   Protection of structure.](https://www.frixlaw.com/law-library/statutes/CFR_T14_P27_S27_609.md)
- [14 C.F.R. § 27.610 (2026) § 27.610   Lightning and static electricity protection.](https://www.frixlaw.com/law-library/statutes/CFR_T14_P27_S27_610.md)
- [14 C.F.R. § 27.611 (2026) § 27.611   Inspection provisions.](https://www.frixlaw.com/law-library/statutes/CFR_T14_P27_S27_611.md)
- [14 C.F.R. § 27.613 (2026) § 27.613   Material strength properties and design values.](https://www.frixlaw.com/law-library/statutes/CFR_T14_P27_S27_613.md)
- [14 C.F.R. § 27.619 (2026) § 27.619   Special factors.](https://www.frixlaw.com/law-library/statutes/CFR_T14_P27_S27_619.md)
- [14 C.F.R. § 27.621 (2026) § 27.621   Casting factors.](https://www.frixlaw.com/law-library/statutes/CFR_T14_P27_S27_621.md)
- [14 C.F.R. § 27.623 (2026) § 27.623   Bearing factors.](https://www.frixlaw.com/law-library/statutes/CFR_T14_P27_S27_623.md)
- [14 C.F.R. § 27.625 (2026) § 27.625   Fitting factors.](https://www.frixlaw.com/law-library/statutes/CFR_T14_P27_S27_625.md)
- [14 C.F.R. § 27.629 (2026) § 27.629   Flutter.](https://www.frixlaw.com/law-library/statutes/CFR_T14_P27_S27_629.md)

---

Source: Frix Law Library, https://www.frixlaw.com/law-library/statutes/CFR_T14_P27_S27_619. Check the current official text before relying on it. Not legal advice.