# Public Housing Assessment System, Physical Condition Scoring Process

> Briefs, arguments, decisions, and more.

URL: https://www.frixlaw.com/law-library/documents/fr%3A99-15738

## Record

- **Collection:** Federal Register
- **Document type:** Notice
- **Published:** June 23, 1999
- **Citation:** 64 FR 33650

## Text

SUMMARY: This notice provides additional information to public housing
agencies and members of the public about HUD's process for issuing
scores under the Physical Condition Indicator of the Public Housing
Assessment System (PHAS).

FOR FURTHER INFORMATION CONTACT: For further information contact Wanda
Funk, Real Estate Assessment Center, Department of Housing and Urban
Development, 1280 Maryland Avenue, SW, Suite 800, Washington, DC 20024;
telephone Customer Service Center at 1-888-245-4860 (this is a toll-
free number). Persons with hearing or speech impairments may access
that number via TTY by calling the Federal Information Relay Service at
(800) 877-8339. Additional information is available from the REAC
Internet Site, http://www.hud.gov/reac.

SUPPLEMENTARY INFORMATION:

Purpose of This Notice

The purpose of this notice is to provide additional information
about the scoring process for PHAS Indicator #1, Physical Condition.
The purpose of the Physical Condition assessment is to ensure that
public housing units are safe, decent, sanitary and in good repair,
using HUD's uniform physical condition standards for the assessment.
The physical condition assessment under the PHAS utilizes uniform
physical inspection procedures to determine compliance with the uniform
standards and is an important indicator of a PHA's performance.
Of the total 100 points available for a PHAS score, a PHA may
receive up to 30 points under PHAS Indicator #1. The physical condition
score is included in the aggregate PHAS score.
The information provided in this notice was originally published on
May 13, 1999 (64 FR 26166). HUD is publishing this information again
since it relates to the Public Housing Assessment System proposed rule,
published in the Federal Register on June 22, 1999. This notice is
different from the May 13, 1999 notice in the following respects: the
information concerning common areas and building exteriors or building
systems has been expanded; a new paragraph 16 is added to Section I,
and previous paragraph 16 is now paragraph 17; and another inspection
summary report model is provided.

The PHAS/REAC Physical Inspection and the HQS Inspection

The PHAS physical inspection is performed by HUD's Real Estate
Assessment Center (REAC), and is also referred to as the REAC physical
inspection. The REAC physical inspection encompasses virtually
everything covered by the Housing Quality Standards (HQS) inspection.
The REAC physical inspection, however, is more objective and more
defined in identifying and classifying deficiencies. While the HQS
inspection generates a reasonably subjective ``pass/fail'' designation,
the REAC inspection generates much more comprehensive results, such as:
Physical scores reported at the property level;
Area level scores for each of the five REAC physical
inspection areas; and
Observations of deficiencies recorded by the inspector
electronically at the time of the inspection.

The Physical Inspection Scoring Process

1. Definitions

The following are the important definitions of terms used in the
physical condition scoring process:
Score means a number between 0 and 100 that reflects the physical
condition of a property, inspectable area, or sub-area:
To record a health or safety problem, a letter is added to
the property score (a, b, or c); and
To note that smoke detectors are inoperable or missing, an
asterisk (*) is added to the property score.
Inspectable area means any of the five major components of the
property, which are:
Site
Building exteriors
Building systems
Common areas
Dwelling units
Sub-area means an inspectable area for one building. For example,
if a property has more than one building, each inspectable area for
each building in the property is treated as a sub-area.
Inspectable items refer to walls, kitchens, bathrooms, and other
things to be inspected in an inspectable area. The number of
inspectable items may vary from 8 to 17 items for each area. Weights
are assigned to each item as shown in Appendix 1 (Item Weights and
Criticality Levels).
Deficiencies refer to specific problems, comparable to HQS, that
can be recorded for the inspectable items, such as a hole in a wall or
a damaged refrigerator in the kitchen.
Criticality means one of five levels that reflect the relative
importance of the deficiencies for an inspectable item. Appendix 1 also
lists all deficiencies with their designated levels, which vary from 1
to 5, with 5 as the most critical. The deficiencies also have assigned
values used in scoring as follows:

------------------------------------------------------------------------
Criticality Level Value
------------------------------------------------------------------------
Critical.............................................. 5 5.00
Very important........................................ 4 3.00
Important............................................. 3 2.25
Contributes........................................... 2 1.25
Slight contribution................................... 1 0.50
------------------------------------------------------------------------

Based on the importance of the deficiency, reflected in its
criticality value, points are deducted from the property score. For
example, a clogged drain in the kitchen is more critical than a damaged
surface on a counter top. Therefore, more points will be deducted for a
clogged drain than for a damaged surface.
Severity means one of three levels that reflect the extent of
damage associated with each deficiency, with values assigned as
follows:

------------------------------------------------------------------------
Severity Value
------------------------------------------------------------------------
Severe......................................................... 1.00
Major.......................................................... 0.50
Minor.......................................................... 0.25
------------------------------------------------------------------------

Appendix 1 shows the severity levels that are possible for each
deficiency. Based on the severity of each deficiency, the score is
reduced. Points deducted are calculated as the product of the item
weight and the values for criticality and severity, as described below.
For specific definitions of each severity level, see the REAC's
``Dictionary of Deficiency Definitions,'' which is available from
REAC's Internet Site, http://www.hud.gov/reac and is reproduced in this
Notice as Appendix 2 (Dictionary of Deficiency Definitions).
Normalized area weights mean weights used with area scores to
create property level scores. The weights are adjusted to reflect the
inspectable items that are present.

2. Scoring Process Input

To generate accurate scores, it is crucial to determine the
appropriate relative weights of the various components of the
inspection; that is, which components are the most important, the next
most important, and so on. To develop the scoring

[[Page 33651]]

methodology for the PHAS physical inspection, HUD utilized information
provided by several knowledgeable parties, including:
Professionals experienced in assessing the physical
condition of properties;
Representatives from the housing and public housing
industries; and
HUD professionals.
In an extensive series of meetings, these parties gave HUD valuable
advice and comments on the relative weights and values for inspectable
areas, items, criticality of deficiencies, and severity levels of
deficiencies.

3. Equity Principles

In addition to determining the appropriate relative weights, HUD
also took into consideration several issues concerning equity between
properties:
Proportionality. The scoring methodology includes an important
control, which does not allow any sub-area scores to be negative. If a
sub-area, such as the building exterior for a given building, has so
many deficiencies that the sub-area score is negative, the score is set
to zero. This control mechanism ensures that no single building or
dwelling unit can affect the overall score more than its proportionate
share of the whole.
Configuration of property. The scoring methodology takes into
account that properties have different numbers of units in buildings.
To fairly score properties with different numbers of units in
buildings, the area scores are calculated for building exteriors and
systems by using weighted averages of the sub-area scores, where the
weights are based on the number of units in each building.
Differences between properties. The scoring methodology also takes
into account that properties have different features and amenities. To
ensure that the overall score reflects only items are present to be
inspected, weights to calculate area and property scores are adjusted
depending on how many items are there to be inspected.

4. Deficiency Definitions

During a physical inspection of a property, the inspector looks for
deficiencies for each inspectable item within the inspectable areas,
such as the walls (item) of a dwelling unit (area). A specific
criticality level is assigned to each deficiency. The criticality level
reflects the importance of the deficiency relative to all deficiencies
for the item. One of three severity levels is also assigned based on
the observed condition.
The REAC's ``Dictionary of Deficiency Definitions'' specifically
defines the three levels of severity: severe, major, and minor. As
noted earlier, this dictionary is found in Appendix 2 to this notice,
and is also available on the REAC Internet Site.

5. Health and Safety Deficiencies

The REAC physical inspection emphasizes health and safety (H&S)
deficiencies because of their crucial importance to the well-being of
residents. H&S deficiencies can substantially reduce the overall
property score. As noted earlier, the H&S deficiencies are highlighted
by adding a letter to the numeric score. Letters to the numeric score
are added as follows:
If there are no H&S deficiencies, add a;
If there are H&S deficiencies that are not life-
threatening (NLT), add b; and
If there are exigent H&S deficiencies that are life
threatening(LT), i.e., calling for immediate attention or remedy--or
fire safety H&S deficiencies, add c.
Appendix 1 lists all H&S deficiencies with an ``LT'' designation
for exigent/fire safety and ``NLT'' for non-life threatening
deficiencies.
To ensure prompt correction of H&S deficiencies, the inspector
gives the property representative the list of every observed exigent/
fire safety H&S deficiency before leaving the site. The property
representative acknowledges receipt of the deficiency report by
signature. The inspector also transmits the deficiency report to HUD
not later than the morning after completing the inspection. HUD sends
to all PHAs inspection reports that summarize the H&S deficiencies
recorded by the inspector. These reports clearly show:
The number of H&S deficiencies (exigent/fire safety and
non-life threatening) that the inspector observed;
All observed smoke detector deficiencies; and
A projection of the total number of H&S problems that the
inspector potentially would see in an inspection of all buildings and
all units.
If there are smoke detector deficiencies, the physical condition
score will include an asterisk. However, problems with smoke detectors
do not currently affect the overall score. When there is an asterisk
indicating the property has at least one smoke detector deficiency,
that part of the score may be identified as ``risk.'' For example,
``93a, risk'' for 93a* and ``71c, risk'' for 71c*.
There are six distinct letter grade combinations: a, a*, b, b*, c
and c*. For example:
A score of 90c* means that the property contains at least
one exigent/fire safety H&S deficiency to be corrected, including some
smoke detector; deficiencies, but is otherwise in excellent condition.
A score of 55a means that the property is in poor
condition, even though there are no H&S deficiencies; and
A property in excellent physical condition with no H&S
deficiencies would have a score of 90a to 100a.

6. Scoring Process Elements

The physical condition scoring process is based on three elements
within a property:
Inspectable areas;
Inspectable items; and
Observed deficiencies.

7. Scoring as Weighted Averages

The score for a property is the weighted average of area scores,
with the area weights adjusted to take into account how many of an
area's inspectable items are actually present to be inspected.
The area scores are calculated by deriving weighted averages of
sub-area scores over buildings or dwelling units as appropriate.
The sub-area scores are calculated by deducting points for
deficiencies, based on criticality and severity levels. (Sub-area
scores may not be less than zero.) Points are also deducted for H&S
deficiencies.

8. Essential Weights and Levels

The process of scoring a property's physical condition depends on
the weights, levels, and associated values of several quantities:
Weights for inspectable areas (5 areas);
Weights for inspectable items within areas (8 to 17 per
area);
Criticality levels and their associated values for the
possible deficiencies within items inspected;
Severity levels and their associated values for
deficiencies; and
Health and safety deductions (exigent/fire safety and non-
life threatening) for site, buildings, and dwelling units.

9. Normalized Area Weights

A property's overall physical condition score is a weighted average
of area scores. Approximate relative weights appeared in the PHAS final
rule, published on September 1, 1998 (see 63 FR 46596, pages 46598-
46599):

[[Page 33652]]

------------------------------------------------------------------------
Weight
Area (percent)
------------------------------------------------------------------------
Site....................................................... 15
Building exterior.......................................... 15
Building systems........................................... 20
Common areas............................................... 15
Dwelling units............................................. 35
------------------------------------------------------------------------

These weights are assigned if all inspectable items are present for
each area for each building and unit. Typically, some areas are missing
a number of inspectable items for some or all buildings or units. For
example, common areas may be missing in some buildings. When items are
missing for an area, the area weight is reduced to reflect the missing
item weights and then all area weights are ``normalized'' so that they
again add up to 100%. As an example, if there were no common areas, the
weights of the other four areas would be reduced to a total of 85%.
Each area's weight then would be divided by 0.85, resulting in
normalized weights of 17.6%, 17.6%, 23.5%, 0% and 41.2% for site,
building exterior, building systems, common areas and units,
respectively. These new weights add to 100%.

10. Site, Unit and Sub-Area Scores

These are the steps to arrive at site, unit and sub-area scores for
a site, building, or unit:
Step 1: Calculate an ``initial proportionate score''--the
difference between the possible points for the site, a building sub-
area, or a unit and the deductions associated with the deficiencies
recorded. The number of possible points is the total of the inspectable
item weights, ignoring the H&S item, for the site, or a building sub-
area, or unit.
Step 2: Calculate the deduction for an observed deficiency by
multiplying the relevant item weight by the criticality value and by
the severity value.
Step 3: In a similar manner, reduce the scores for any health and
safety (H&S) deficiencies observed, including those in the H&S item and
those in other non-H&S items. (The item weight for deficiencies
included in the H&S item is equal to the largest weight among the items
present.) At this point, the control to prevent negative scores is
applied. Thus, no one building or unit may affect an area score more
than its proportionate share would justify.
Step 4: Normalize the resulting proportionate scores to scores
based on 100 points by dividing by the total of weights of items
present to be inspected, other than the H&S item.

11. Area Scores

Within each area involving either multiple buildings or units, the
area score is a weighted average of the building sub-area scores or
unit scores. To calculate these weighted averages, follow these
guidelines:
Dwelling units: The area score is the weighted average of sub-area
scores for each unit, weighted by the total of item weights present to
be inspected in each unit.
Common areas: Like the dwelling unit score, the area score for
common areas is the weighted average of sub-area common area scores
weighted by the total weights for items inspected in the common areas
for each building. When computing area scores for common areas, there
may be special considerations when there are common buildings with no
units. All common buildings with no units are inspected. In those cases
where a sample is taken of buildings with units, the effect of common
buildings on the common area score should be reduced. This reduction is
accomplished by multiplying the weights for common buildings by the
number of units in inspected buildings, divided by the total number of
units in the property.
Building exteriors or building systems: The area scores for
building exteriors and building systems are weighted averages of sub-
area scores. The weights are the product of the total weights for
items, ignoring the H&S item, inspected for each building exterior or
systems times the total number of units for each building. (Note: the
total number of units is all units, not just units inspected.) When
computing area scores for building exterior or building systems, a
number of adjustments are made for common buildings without units. In a
manner identical to that for common areas, if buildings with units are
sampled, the weights of common building scores are reduced. Also for
weighting purposes, a common building is assigned the average number of
units in all buildings, including all common buildings and all
buildings with units, whether inspected or not. Finally, to adjust for
differences in size between common buildings, a common building's
weight is multiplied by the total weight of items present to be
inspected for the building's common areas.

12. Overall Property Score

To calculate the overall property score, the normalized area
weights are applied to the area scores.

13. Possible Points

Normalized area weights reflect both the initial weights and the
relative weights between areas of inspectable items actually present.
For reporting purposes, normalized weights are presented as the maximum
point contributions for each of the five inspectable areas. In the
Physical Inspection Report, sent to all PHAs, the following items are
listed:
Normalized weights as the ``possible points'' by area;
The area scores, taking into account the points deducted
for observed deficiencies;
The deductions for H&S for site, buildings and units,
where H&S deductions for buildings are combined for exteriors, systems
and common areas; and
The overall property score.
The Physical Inspection Report allows the PHA to see the magnitude
of the points lost by inspectable area, and the impact on the score of
the H&S deficiencies.

14. Examples of Physical Condition Score Calculations

To illustrate how physical condition scores are calculated, three
examples are provided below.
Example #1: Example #1 illustrates how the score for a sub-area is
calculated based on the following features:
#1a. Ignoring the H&S item, the other seven items have a total
weight of 100%, as shown in Appendix 1. If the building had no fire
escapes, an item with a nominal weight of 16.7%, then the total item
weight for the remaining non-H&S items would be 83.3%, which is then
the base (83.3 points) from which deductions are made to create the
``initial proportionate score'' as described, above, under Sub-Area
Scores.
#1b. Assume damaged vents were found in the roof. The criticality
level for this deficiency is provided in Appendix 1 as a 4, which has a
value of 3.00 as given, above, under Definitions. If, based on the
Dictionary of Deficiency Definitions (Appendix 2), it is determined
that the damaged vents seen are minor deficiencies, then the amount of
points deducted is the item weight (16.7) times the criticality value
(3.00), times the severity value (0.25), which equals 12.5 points.
#1c. If this is the only deficiency observed, then the initial
proportionate score for this sub-area would be 83.3 - 12.5 or 70.8
points.
#1d. Additional deficiencies or H&S deficiencies (calculated in the
same

[[Page 33653]]

manner) would further decrease the sub-area score and if the score
dropped below zero, then it would be changed to zero.
#1e. The initial proportionate sub-area score is then normalized to
a 100 point basis by dividing by the total of the non-H&S item weights
(0.833), which would create the final score of (70.8)/(0.833) = 85.0
Example #2
Example #2 illustrates how the score for an area is calculated
based on the following features:
#2a. Consider a property with 2 buildings with the following
characteristics:

Building #1 (from Example #1, above):

--10 units
--83.3% of the weight for the items that were present in building
exterior
--Building exterior score is 85 points

Building #2:

--20 units
--100% of the weight for the items that were present in building
exterior
--Building exterior score is 70 points

#2b. The building exterior score for the building exterior area is
the weighted average of the individual scores. Each building exterior
score is weighted by the number of units and the percent of the weight
for items present in the building exterior.
#2c. The scores for buildings #1 and #2, above, are calculated
using the following formula: Building Exterior Score = sum of
[(Building score) times (Building weight divided by the sum of Building
weights)]

Building #1 weight: [(10 units)*(83.3% weight)] = 8.33
Building #2 weight: [(20 units)*(100% weight)] = 20
Total weight = 8.33 + 20, or 28.33
Building exterior score = (85 points)*(8.33/28.33) + (70
points)*(20/28.33)
= 25.0 + 49.4
= 74.4
Example #3
Example #3 illustrates how the score for a property is calculated
based on the following:
#3a. Consider a property with the following characteristics:
Site:

--Score: 90 points
--100% of weight of items present
--Nominal weight: 15%

Building Exteriors (from example #2, above):

--Score: 74 points
--92% of weight of items present
--Nominal weight: 15%

Building Systems:
--Score: 70 points
--80% of weight of items present
--Nominal weight: 20%

Common Areas:

--Score: 60 points
--30% of weight of items present
--Nominal weight: 15%

Dwelling Units:

--Score: 80 points
--80% of weight of items present
--Nominal weight: 35%

#3b. First, adjust the area weights for each area. Multiply the
weight of items present by the nominal weight for each area and add the
total:

Site: 15*100% = 15
Building Exteriors: 15*92% = 13.8
Building Systems: 20*80% = 16.0
Common Areas: 15*30% = 4.5
Dwelling Units: 35*80% = 28.0
------------------------------------------
Total: = 77.3

#3c. Adjust the area weights to ``normalize'' so that they add to
100. Divide each adjusted area weight by the total and multiply by 100
(this also results in the maximum possible points reported for each
area):

Site: (15/77.3)*10 =19.4
Building (13.8/77.3)*100 =17.9
Exteriors:
Building Systems: (16/77.3)*100 =20.7
Common Areas: (4.5/77.3)*100 = 5.8
Dwelling Units: (28/77.3)*100 = 36.2

#3d. Multiply the new ``normalized'' weights by the area scores,
above, divide by 100, and add the results:

------------------------------------------------------------------------
Points
------------------------------------------------------------------------
Site: 19.4 * 90/100................. = 17.5
Building Exteriors: 17.9 * 74/100 = 13.2
Building Systems: 20.7 * 70/100 = 14.5
Common Areas: 5.8 * 60/100 = 3.5
Dwelling Units: 36.2 * 80/100 = 29.0
------------------------------------------------------------------------
Total Property Score............ = 77.6
------------------------------------------------------------------------

15. Computing the PHAS Overall Physical Inspection Score

The physical inspection score for the PHAS for a PHA is the
weighted average of the PHA's individual project physical inspection
scores, where the weights are the number of units in each project
divided by the total number of units in all projects for the PHA.

Example:
Project 1 has a score of 60 and has 100 units.
Project 2 has a score of 80 and has 900 units.

The overall PHAS score is computed as follows:

Score = [60 x 100/(100+900)] + [80 x 900/(100+900)]
= 6 + 72
= 78

16. Accessibility Questions

For public housing developments for which accessibility
requirements are applicable, the physical inspection will include
determining if: (1) There is a wheelchair accessible route to and from
the main ground floor entrance of the buildings inspected; (2) the main
entrance for every building inspected is at least 32'' wide, measured
between the door and the opposite door jamb; (3) there is an accessible
route to all exterior common areas; and (4) for multistory buildings
that are inspected, the interior hallways to all inspected units and
common areas are at least 36'' wide.

17. Inspection Summary Report

Appendix 3 includes an inspection summary report which provides
another example of the information sent to PHAs.

Dated: June 14, 1999.
Donald J. LaVoy,
Acting Director, Real Estate Assessment Center.

BILLING CODE 4210-32-P

[[Page 33654]]

[GRAPHIC] [TIFF OMITTED] TN23JN99.042

[[Page 33655]]

[GRAPHIC] [TIFF OMITTED] TN23JN99.043

[[Page 33656]]

[GRAPHIC] [TIFF OMITTED] TN23JN99.044

[[Page 33657]]

[GRAPHIC] [TIFF OMITTED] TN23JN99.045

[[Page 33658]]

[GRAPHIC] [TIFF OMITTED] TN23JN99.046

[[Page 33659]]

[GRAPHIC] [TIFF OMITTED] TN23JN99.047

[[Page 33660]]

[GRAPHIC] [TIFF OMITTED] TN23JN99.048

[[Page 33661]]

[GRAPHIC] [TIFF OMITTED] TN23JN99.049

[[Page 33662]]

[GRAPHIC] [TIFF OMITTED] TN23JN99.050

[[Page 33663]]

[GRAPHIC] [TIFF OMITTED] TN23JN99.051

[[Page 33664]]

[GRAPHIC] [TIFF OMITTED] TN23JN99.052

[[Page 33665]]

[GRAPHIC] [TIFF OMITTED] TN23JN99.053

[[Page 33666]]

[GRAPHIC] [TIFF OMITTED] TN23JN99.054

[[Page 33667]]

[GRAPHIC] [TIFF OMITTED] TN23JN99.055

[[Page 33668]]

[GRAPHIC] [TIFF OMITTED] TN23JN99.056

[[Page 33669]]

[GRAPHIC] [TIFF OMITTED] TN23JN99.057

[[Page 33670]]

[GRAPHIC] [TIFF OMITTED] TN23JN99.058

[[Page 33671]]

[GRAPHIC] [TIFF OMITTED] TN23JN99.059

[[Page 33672]]

[GRAPHIC] [TIFF OMITTED] TN23JN99.060

[[Page 33673]]

[GRAPHIC] [TIFF OMITTED] TN23JN99.061

[[Page 33674]]

[GRAPHIC] [TIFF OMITTED] TN23JN99.062

[[Page 33675]]

[GRAPHIC] [TIFF OMITTED] TN23JN99.063

BILLING CODE 4210-32-C

Appendix 2--Dictionary of Deficiency Definitions

Site Inspectable Items

Items to inspect for ``Site'' are as follows:

Fencing and Retaining Walls
Grounds
Lighting
Mailboxes/Project Signs
Market Appeal
Parking Lots/Driveways/Roads
Play Areas and Equipment
Refuse Disposal
Storm Drainage
Walkways/Stairs

Fencing and Retaining Walls (Site)

A structure functioning as a boundary or barrier. An upright
structure serving to enclose, divide or protect an area.

Note: This does not include swimming pool fences. Swimming Pool
Fences are covered under Common Areas--Pools and Related Structures.

This inspectable item can have the following deficiencies:

Damaged or Missing Gates
Damaged/Falling/Leaning
Holes
Missing Sections

Grounds (Site)

The improved land adjacent to or surrounding the housing and
related structures. This does not include land not owned or under
the control of the housing provider.
This inspectable item can have the following deficiencies:

Erosion Areas
Overgrown/Penetrating Vegetation
Ponding/Site Drainage
Rutting

Lighting (Site)

System to provide illumination of the community grounds.
Includes fixtures, lamps, stanchions, poles, supports, and
electrical supply.
This inspectable item can have the following deficiencies:

Broken Fixtures
Missing/Broken Bulbs

Mailboxes/Project Signs (Site)

Mailbox is a public container where mail is deposited for
distribution and collection. This does not include mailboxes owned
and maintained by the US Postal Service, such as the ``Blue Boxes.''
Project signs are boards, posters, or placards displayed in a
public place to advertise, impart information, or give directions.
This does not include signs owned and maintained by the city.
This inspectable item can have the following deficiencies:

Mailbox Missing/Damaged
Signs Missing/Damaged

Market Appeal (Site)

Evaluate only those areas or structures that are under the
control of the housing provider.
This inspectable item can have the following deficiencies:

Graffiti
Litter

Parking Lots/Driveways/Roads (Site)

An area for parking motorized vehicles begins at the curbside
and includes all parking lots, driveways or roads within the
property lines that are under the control of the housing provider.
This inspectable item can have the following deficiencies:

Cracks
Ponding
Potholes/Loose Material
Settlement/Heaving

Play Areas and Equipment (Site)

An outdoor area set aside for recreation or play, especially one
containing equipment such as seesaws and swings.
This inspectable item can have the following deficiencies:

Damaged/Broken Equipment
Deteriorated Play Area Surface

Refuse Disposal (Site)

Collection areas for trash/garbage common pick-up.
This inspectable item can have the following deficiencies:

Broken/Damaged Enclosure
Inadequate Outside Storage Space

Storm Drainage (Site)

System used to collect and dispose of surface runoff water
through the use of culverts, underground structures, or natural
drainage features, e.g., swales, ditches, etc.
This inspectable item can have the following deficiencies:

Damaged/Broken/Cracked
Debris/Obstruction/Sediment

Walkways/Stairs (Site)

Passages for walking and the structures that allow for changes
in vertical orientation.
This inspectable item can have the following deficiencies:
Broken/Missing Hand Railing
Cracks/Settlement/Heaving
Spalling

Damaged or Missing Gates (Fencing and Retaining Walls)

Gate structure is damaged or missing and does not prevent
passage.
This does not include gates for swimming pool fences. Gates for
swimming pool fences are covered under Common Areas--Pools and
Related Structures.

Note: Deficiency level depends on the fence's purpose.
Perimeter/Security Fences

[[Page 33676]]

are assessed at a higher level than interior fences.

Severity Defined

Minor: N/A.
Major: Absence or damage to an interior fence gate which renders
a gate inoperable/ineffective.
OR
Damage to a perimeter or a security fence gate that is still
operational.
Severe: Absence or damage to a perimeter or security gate which
renders the gate inoperable/ineffective and potentially compromises
safety and/or security.

Damaged/Falling/Leaning (Fencing and Retaining Walls)

Structure is rusted, deteriorated, uprooted presents threat to
security and/or health and safety.

Note: Deficiency level depends on the fence's purpose.
Perimeter/Security Fences are assessed at a higher level than
interior fences.

Severity Defined

Minor: N/A.
Major: An interior fence is damaged so that it does not satisfy
its designed purpose.
OR
A perimeter/security fence and/or a retaining wall shows signs
of deterioration, but still serves its designed purpose and presents
no security/safety risk.
Severe: A perimeter/security fence and/or a retaining wall is
damaged to the point that it does not satisfy its designed purpose.

Holes (Fencing and Retaining Walls)

An opening or penetration.

Note: Some fences are not designed to keep intruders out or
children in such as rail fences, and these type of fences should not
be evaluated for holes.

Severity Defined

Minor: Hole is smaller than 6'' x 6'' piece of paper.
Major: N/A.
Severe: Hole is larger than 6'' x 6'' which allows passage of
animals and can pose a threat to the safety of children.

Missing Sections (Fencing and Retaining Walls)

Structure does not present an obstacle against intrusion or
egress--damaged by the destruction or removal of section.

Note: Deficiency level depends on the fence's purpose.
Perimeter/Security fences are assessed at a higher level than
interior fences.

Severity Defined

Minor: An interior fence has section missing.
Major: N/A.
Severe: A perimeter/security fence has a section missing which
compromises safety/security.

Erosion Areas (Grounds)

An area subjected to natural processes, such as weathering or
gravity, by which material is moved on the earth's surface.

Note: This does not include erosion from a defined storm
drainage system or in a play area. This type of erosion would be
covered under Site--Storm Drainage and/or Site--Play Areas and
Equipment.

Severity Defined

Minor: N/A.
Major: Visible collection of surface material indicated by
visible erosion deposits leading to a degraded surface condition
that would likely cause water to pool in a confined area, especially
next to structures, paved areas or walkways.
Severe: Extensive displacement of soil caused by runoff.
Condition is responsible for visible damage or the potential failure
of adjoining structures or systems, e.g., pipes, pavements,
foundations, building, etc.
OR
Advanced erosion in an area which creates an unsafe pedestrian
condition and/or renders an area of the grounds unusable.

Overgrown/Penetrating Vegetation (Grounds)

Plant life that has infiltrated unacceptable areas and/or has
grown beyond established parameters.

Severity Defined

Minor: N/A.
Major: Vegetation is of such size or density as to make the
visibility of hazards, such as broken glass, holes, etc., difficult.
OR
Plant life is in contact with an unintended surface, such as,
buildings, gutters, walkways, roads, fences/walls, roofs, HVAC
units, etc.
OR
Vegetation is of such size or density that it obstructs intended
walkways.
Severe: Plants have rendered visible damage to a component,
area, or system of the property or have made them unusable.

Ponding/Site Drainage (Grounds)

An accumulation of water and/or ice is observed to be collecting
in a depressed area or has collected on the grounds for which
ponding was not intended.

Note: This does not include detention/retention basins NOR
ponding on paved areas. Detention/retention basins are covered under
Site--Storm Drainage and ponding on paved areas is covered under
Roads, Walkways, and Parking Lots/Driveways.

Severity Defined

Minor: Shallow accumulation of water (less than 3 inches).
Major: An accumulation of water (from 3 to 5 inches in depth)
that affects the use of a section of the grounds; however, the
grounds are generally usable.
Severe: An accumulation of more than 5 inches in depth.
OR
An accumulation that has rendered a section of the grounds
unusable.

Rutting (Grounds)

A man made sunken track or groove/depression.

Note: These are typically made by a car, bike or other machine.

Severity Defined

Minor: N/A.
Major: Condition that is 6-8'' wide x 3-5'' deep.
Severe: Condition larger than 6-8'' wide x 3-5'' deep and has
the potential to cause serious injury.

Comments

Severe: If condition is a health and safety concern, it must be
recorded manually. (Includes but not limited to ``Hazards'').

Broken Fixtures (Lighting)

All or a portion of the lighting that is associated with the
site itself. This includes lighting attached to the building which
is utilized for such purposes as lighting the site, but does not
include exterior lighting, associated with the building.

Note: If a damaged fixture or fixtures presents a safety hazard,
rate it as severe, and recorded manually as a health and safety
concern. This includes, but is not limited to, broken fixtures that
have the potential to fall on pedestrians, or fixtures that could
lead to electrocution.

Severity Defined

Minor: N/A.
Major: Between 10% and 50% of the lighting fixtures surveyed are
visibly broken. The broken portion of the system does not constitute
an obvious safety hazard.
Severe: Over 50% of the lighting fixtures surveyed are visibly
broken; or the broken portion of the system constitutes an obvious
safety hazard.

Comments

Severe: If condition is a health and safety concern, it must be
recorded. (Includes but not limited to ``Electrical Hazards'' or
``Hazards'.)

Missing/Broken Bulbs (Lighting)

Lamps are missing or are broken from fixtures. May include
incandescent, fluorescent, mercury vapor, or others.

Note: This does not include building exterior lighting. Building
exterior lighting is covered under Building Exterior--Lighting.

Severity Defined

Minor: N/A.
Major: Between 10% and 50% of the fixtures surveyed have at
least a single bulb missing or broken.
Severe: Over 50% of the fixtures surveyed have at least a single
bulb missing or broken.

Comment

Severe: If condition is a health and safety concern, it must be
recorded manually. (Includes but not limited to ``Electrical
Hazards.'')

Mailbox Missing/Damaged (Mailbox/Project Signs)

Mailbox does not function properly due to deterioration, damage,
or is absent.

Severity Defined

Minor: Mailbox is damaged, vandalized, or deteriorated, but
functional.

Major: N/A.

Severe: Mailbox is damaged, vandalized, or deteriorated, and as
a result, is not functional.
OR
Mailbox is missing.

[[Page 33677]]

Signs Missing/Damaged (Mailbox/Project Signs)

Project sign is not readable due to deterioration, damage, or is
absent. This does not include locations that do not require a
project sign.

Severity Defined

Minor: Sign is damaged, vandalized, or deteriorated, but
readable.
Major: N/A.
Severe: Sign is damaged, vandalized, or deteriorated, and as a
result, is not readable.
OR
Sign is missing.

Comments

Severe: Missing signs should only be recorded where a sign is
required. This would follow from evidence that a sign has been
removed through vandalism and/or neglect, etc.

Graffiti (Market Appeal)

Visual observation of a crude, (not recognizable as an art
form), inscription or drawing scratched, painted or sprayed on a
building surface, retaining wall, or fence so as to be seen by the
public.

Note: Do not count full wall murals and similar art forms as
graffiti.

Severity Defined

Minor: Visual graffiti observed in at least one location/area.
Major: Graffiti observed in 2-5 locations/areas.
Severe: Graffiti observed in 6 or more locations/areas.

Litter (Market Appeal)

Subject to disorderly accumulation of objects, especially
carelessly discarded trash located on the property.

Note: Excessive litter should be judged as you would view a city
park in America.

Severity Defined

Minor: N/A.
Major: Excessive litter is observed on the property.
Severe: N/A.

Cracks (Parking Lots/Driveways/Roads)

Visible faults in the pavement, including longitudinal, lateral,
alligator, etc. This does not include cracks from settlement/
heaving.

Severity Defined

Minor: N/A.
Major: A crack which is up to \1/2\'' wide.
Severe: A crack larger than \1/2\'' or multiple cracks
accompanied by surface deterioration.

Comments

Severe: If condition is a health and safety concern, it must be
recorded manually. (Includes but not limited to ``Hazards.'')

Ponding (Parking Lots/Driveways/Roads)

A visible accumulation of water and/or ice collecting in a
depression on an otherwise flat plane.

Severity Defined

Minor: Shallow accumulation of water (less than 3'').
Major: An accumulation of water that affects the use of a
section of a parking lot/driveway more than 3'' in depth. Parking
lot/driveway is passable.
Severe: An accumulation of water that has rendered a parking
lot/driveway unusable.

Potholes/Loose Material (Parking Lots/Driveways/Roads)

A hole resulting from road surface failure; or loose,
freestanding aggregate material is observed resulting from
deterioration.

Severity Defined

Minor: Failure of pavement due to potholes or loose material
that has not penetrated to or exposed the subsurface.
Major: Failure of pavement due to potholes or loose material
that has penetrated to or exposed the subsurface.
Severe: Loose material and/or potholes that render a parking
lot/driveway unusable/unpassable.

Comments

Severe: If condition is a health and safety concern, it must be
recorded manually. (Includes but not limited to ``Hazards.'')

Settlement/Heaving (Parking Lots/Driveways/Roads)

Pavement that sinks and/or rises due to failure of subbase
materials.

Note: If there is a visible accumulation of water and/or ice
collecting in the depression, record the observation under ponding.

Severity Defined

Minor: Visual indication of settlement/heaving with no visible
surface cracks.
Major: Visual indication of settlement/heaving evidenced by
cracks and deteriorated surface material.
Severe: Settlement/Heaving that renders a parking lot/driveway
unusable/unpassable and/or creates unsafe pedestrian conditions.

Comments

Severe: If condition is a health and safety concern, it must be
recorded manually. (Includes but not limited to ``Hazards.'')

Damaged/Broken Equipment (Play Areas and Equipment)

Forcibly fractured into pieces or shattered, incomplete,
inoperable, or missing.

Severity Defined

Minor: Visual estimate indicates some equipment (less than 50%)
does not operate correctly or is missing but pose no safety risk.
Major: Visual estimate indicates most of the equipment (more
than 50%) does not operate correctly or is missing but pose no
safety risk.
Severe: Equipment poses a threat to safety capable of causing
injury.

Deteriorated Play Area Surface (Play Areas and Equipment)

Damage to play area caused by cracking, heaving, settling,
ponding, potholes, loose materials, erosion, rutting, etc.

Severity Defined

Minor: Up to 10% of total surveyed play area surface shows signs
of deterioration.
Major: Deterioration of 10 to 50% of total surveyed play area
surface.
Severe: Deterioration of more than 50% of the surveyed play area
surface.

Comments

Severe: If condition is a health and safety concern, it must be
recorded manually. (Includes but not limited to ``Hazards.'')

Broken/Damaged Enclosure (Refuse Disposal)

The outdoor enclosed area which serves as a trash/refuse site is
broken or damaged including its walls.

Note: This does not include areas not designed as trash/refuse
enclosures such as curb pick-up. Address condition of slab at
parking lots/driveways/roads.

Severity Defined

Minor: N/A.
Major: A single wall or gate has holes or missing components.
Severe: A single wall or gate of the enclosure has collapsed or
is leaning and in danger of falling.

Comments

Severe: If condition is a health and safety concern, it must be
recorded manually. (Includes but not limited to ``Hazards.'')

Inadequate Outside Storage Space (Refuse Disposal)

Insufficient capacity for the proper storage of refuse until
disposal.

Note: This does not include curb side pick-up areas.

Severity Defined

Minor: Appearance of storage area is unsightly and needs
improvement, or the area surrounding the refuse storage area is
impacted by the presence of unpleasant odors.
Major: N/A.
Severe: Trash cannot be stored in the designated area due to
under-capacity of refuse storage.

Damaged/Broken/Cracked (Storm Drainage)

Separated into pieces. Broken, but not into parts (fractured).

Severity Defined

Minor: N/A.
Major: Visible structural damage/failure impacting the system's
effectiveness. Significant visible fracture evidence by large,
visible cracks.
Severe: Visible deterioration or failure of a large section
yielding an inoperable system.

Debris/Obstruction/Sediment (Storm Drainage)

Partial or complete blockage by broken or collapsed pipe,
infiltration of tree roots, accumulation of sediment, or other
obstructions.

Severity Defined

Minor: N/A.
Major: Accumulation of debris or sediment which causes or has
the estimated potential of significantly reducing the flow of storm
water.
Severe: Complete blockage of the system due to accumulation of a
large quantity of debris causing backups into adjacent area(s).

Broken/Missing Hand Railing (Walkways/Steps)

The hand rail is damaged or non-existent.

[[Page 33678]]

Severity Defined

Minor: N/A.
Major: N/A.
Severe: The hand-rail for four or more stairs is completely
missing or damaged, loose or otherwise unusable.

Cracks/Settlement/Heaving (Walkways/Steps)

Visible faults in the pavement, including longitudinal, lateral,
alligator, etc. Pavement that sinks and/or rises due to failure of
subbase materials.

Note: This does not include cracks on parking lots/driveways or
roads.

Severity Defined

Minor: N/A.
Major: Evidence of cracks or other defects which do not affect
traffic ability.
Severe: Cracks/hinging/tilting and/or missing sections that
affect traffic ability.

Comments

Severe: If condition is a health and safety concern, it must be
recorded manually. (Includes but not limited to ``Hazards.'')

Spalling (Walkways/Steps)

A concrete or masonry walkway that is flaking, chipping or
crumbling, possible exposing underlying reinforcing material.

Severity Defined

Minor: Small areas, (4'' x 4'' or less), of walkway/stairs are
affected.
Major: N/A.
Severe: Large areas, (greater than 4'' x 4''), of walkway/stairs
are impacted and affects traffic ability.

Comments

Severe: If condition is a health and safety concern, it must be
recorded manually. (Includes but not limited to ``Hazards.'')

Building Exterior Inspectable Items

Items to inspect for ``Building Exterior'' are as follows:

Doors
Fire Escapes
Foundations
Lighting
Roofs
Walls
Windows

Doors (Building Exterior)

Means of access to the interior of a building or structure.
Doors provide privacy, control passage, maintain security, provide
fire and weather resistance. Includes entry to maintenance areas,
boiler and mechanical rooms, electrical vaults, storage areas, etc.

Note: This does not include unit doors.

This inspectable item can have the following deficiencies:

Broken/Missing Glazing/Glass
Damaged Frames/Threshold/Lintels/Trim
Damaged Hardware/Locks
Damaged Surface (Holes/Paint/Rusting)
Deteriorated/Missing Caulking Seals
Missing Door
Damaged/Missing Screen/Storm/Security Door

Fire Escapes (Building Exterior)

All buildings must have acceptable fire exits. This includes
both stairway access doors & external exits. These can include
external fire escapes, fire towers, operable windows on the lower
floors with easy access to the ground or a back door opening onto a
porch with a stairway leading to the ground.
This inspectable item can have the following deficiencies:

Blocked Egress/Ladders
Visibly Missing Components

Foundations (Building Exterior)

Lowest level structural wall or floor responsible for
transferring the building's load to the appropriate footings and
soil. Materials may include concrete, stone, masonry and wood.
This inspectable item can have the following deficiencies:

Cracks/Gaps
Spalling/Exposed Rebar

Lighting (Building Exterior)

System to provide illumination of building exteriors and
surrounding grounds. Includes fixtures, lamps, stanchions, poles,
supports, and electrical supply that are associated with the
building itself.

Note: This does not include site lighting.

This inspectable item can have the following deficiencies:

Broken Fixtures
Missing/Broken Bulbs

Roofs (Building Exterior)

Roof system consists of the structural deck, weathering surface,
flashing, parapet, and drainage system. They may be flat or pitched.
This inspectable item can have the following deficiencies:

Damaged/Clogged Drains
Damaged Soffits/Fascia
Damaged Vents
Damaged/Torn Membrane/Missing Ballast
Missing/Damaged Shingles
Ponding (Roofs)
Missing/Damaged Components from Downspout/Gutter

Walls (Building Exterior)

The exterior enclosure of the building or structure. Materials
for construction include concrete, masonry block, brick, stone,
wood, glass block. Surface finish materials include metal, wood,
vinyl, stucco.

Note: This does not include foundation walls.

This inspectable item can have the following deficiencies:

Cracks/Gaps
Damaged Chimneys
Missing Pieces/Holes/Spalling
Stained/Peeling/Needs Paint
Missing/Damaged Caulking/Mortar

Windows (Building Exterior)

Window systems provide light, security, and exclusion of
exterior noise, dust, heat, and cold. Frame materials include wood,
aluminum, vinyl, etc.

Note: This does not include windows that have defects noted from
inspection from inside the unit.

This inspectable item can have the following deficiencies:

Broken/Missing/Cracked Panes
Damaged/Missing Screens
Damaged Sills/Frames/Lintels/Trim
Security Bars Prevent Egress
Missing/Deteriorated Caulking/Glazing Compound
Peeling/Needs Paint

Broken/Missing Glazing/Glass (Doors)

The glass and/or compound/structure to support and hold glass or
other materials within a frame are missing or broken.

Severity Defined

Minor: For one or more doors, glazing is inadequate to secure
glass, but door is usable and presents no immediate security risk.
Major: N/A.
Severe: For at least one door, the operation, function, or
security of the door is destroyed by the missing or broken glazing
and/or glass. One door in this condition is sufficient to classify
the door system as severe.

Damaged Frames/Threshold/Lintels/Trim (Doors)

The frame, header, jamb, threshold, lintels, or trim, is visibly
warped, split, cracked, or broken in some manner.

Severity Defined

Minor: A single door's frame/threshold/lintel and/or trim is
damaged but does not hinder door operation. The damaged door frame
does not prevent door from being locked.
Major: More than one door has the minor damage defined above.
Severe: At least one door is rendered inoperable and/or
unlockable due to damage to the door's frame/threshold/lintel and/or
trim.

Damaged Hardware/Locks (Doors)

The attachments to a door to provide hinging, hanging, opening,
closing, or security are damaged or missing. Includes locks, panic
hardware, overhead door tracks, springs and pulleys, sliding door
tracks and hangers, and door closures.

Severity Defined

Minor: A single door's hardware, as defined above, is damaged
but does not hinder current door operation. The door functions, is
lockable, and the door's panic hardware is operable.
Major: More than one building exterior door has minor damaged
hardware as defined above.
Severe: A single door is rendered inoperable and/or unlockable
(if locking is required) due to damage to the door's hardware.
OR
A single building exterior door's panic hardware is not
operable.

Comments

Severe: If condition is a health and safety concern, it must be
recorded manually.

(Includes but not limited to ``Hazards.'')

[[Page 33679]]

Damaged Surface (Holes/Paint/Rusting) (Doors)

Damage in the door surface that may affect either the surface
protection or the strength of the door, or it may compromise
building security. Includes holes, peeling/cracking/no paint, or
significant rust.

Severity Defined

Minor: Any one door has either: small holes (less than \1/4\
inch in diameter); cracking/peeling paint; and/or the door or its
components are rusting.
Major: If more than one door has minor surface damage as defined
above.
OR
Any single door that has a hole or holes ranging in size from
\1/4\ inch up to 1 inch in diameter.
Severe: Any single door has a hole or holes larger than 1 inch
in diameter, or significant peeling/cracking/no paint or rust that
affects the integrity of the door surface.

Deteriorated/Missing Caulking/Seals (Doors)

Sealant and stripping designed to provide weather resistance or
caulking is missing or deteriorated.

Severity Defined

Minor: For a single door, missing or deteriorated caulk is
confined to small areas with no evidence of damage to the door and/
or surrounding structure.
Major: For a single door, missing or deteriorated caulk is
consistently evident for the majority of the door with no evidence
of damage to the door and/or surrounding structure.
OR
2 or more of the doors surveyed have minor deficiencies.
Severe: For at least one door, missing or deteriorated caulking
is evident along with evidence of leaks or damage to the door or
surrounding structure; or more than half the total door surveyed
have minor caulking deficiencies.
OR
The seal is missing.

Missing Door (Doors)

Door is absent.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: A single missing building exterior door constitutes a
severe condition.

Comments

Severe: If condition is a health and safety concern, it must be
recorded manually. (Includes but not limited to ``Hazards.'')

Blocked Egress/Ladders (Fire Escapes)

Any part of the fire escape, including ladders, is visibly
blocked in a way that limits or restricts clear egress. (Note: This
may include actual fire escapes themselves, fire towers, windows on
the ground floor level that would be used in case of an emergency,
etc.)

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Items are stored or barriers are present such that clear
egress is restricted or blocked.

Visibly Missing Components (Fire Escapes)

Any components that affect functionality of the fire escape are
visibly missing.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Functional components are visibly missing (such as one
section of a ladder is not present or a railing is missing).

Cracks/Gaps (Foundations)

Visible split in the exterior of the lowest structural wall.

Note: Cracks that show evidence of water penetration should be
evaluated here.

Severity Defined

Minor: Visible hairline cracks that do not appear to provide
opportunity for water penetration.
OR
Minor broken pieces from settlement (e.g., a single brick).
Major: Cracks that exceed \1/8\'' in width or depth. May also
provide opportunities for water penetration.
OR
Large pieces, such as numerous bricks, that are separated from
the wall/floor.
Severe: Large cracks or gaps visibly estimated to exceed 3/8''
in width or depth possibly indicating a serious structural problem.
OR
Cracks that are the full depth of the wall and/or provide
opportunity for water penetration.
OR
Wall/floor sections that are broken apart.

Comments

Severe: Request an inspection by a structural engineer if doubt
about severity exists.

Spalling/Exposed Rebar (Foundations)

The concrete or masonry wall that is flaking, chipping, or
crumbling possibly exposing underlying reinforcing material (rebar).

Severity Defined

Minor: Spalling is confined to areas affecting less than 10% of
the foundation wall area inspected.
Major: Obvious large spalled area(s) affecting 10% to 50% of any
individual foundation wall.
Severe: Obvious significant spalled area(s) affecting 50% or
more of any individual foundation wall.
OR
Spalling which causes any reinforcing material (rebar or other)
to be exposed.

Comments

Severe: Request an inspection by a structural engineer if doubt
about severity exists.

Broken Fixtures (Lighting)

All or a portion of the lighting that is associated with the
building itself. This does not include lighting attached to the
building utilized for purposes such as lighting the site.

Note: If a damaged fixture or fixtures presents a safety hazard,
rate it as severe, and recorded manually as a health and safety
concern. This includes, but is not limited to, broken fixtures that
have the potential to fall on pedestrians, or fixtures that could
lead to electrocution.

Severity Defined

Minor: N/A.
Major: Between 10% and 50% of the lighting fixtures surveyed are
visibly broken. The broken portion of the system does not constitute
an obvious safety hazard.
Severe: Over 50% of the lighting fixtures surveyed are visibly
broken; or the broken portion of the system constitutes an obvious
safety hazard.

Comments

Severe: If condition is a health and safety concern, it must be
recorded manually.

(Includes but not limited to ``Electrical Hazards'' or ``Hazards.'')

Missing/Broken Bulbs (Lighting)

Lamps are missing or broken from fixtures. May include
incandescent, fluorescent, mercury vapor, or others.

Note: This does not include SITE Lighting. Site Lighting is
covered under Site--Lighting.

Severity Defined

Minor: N/A.
Major: Between 10% and 50% of the fixtures surveyed have at
least a single bulb visibly missing or broken.
Severe: Over 50% of the fixtures surveyed have at least a single
bulb visibly missing or broken.

Comments

Major: If condition is a health and safety concern, it must be
recorded manually. (Includes but not limited to ``Electrical
Hazards.'')

Damaged/Clogged Drains (Roofs)

The drainage system does not effectively remove water.

Note: Generally, this deficiency applies to flat roofs. This
does not include gutters and downspouts. Refer to Building
Exterior--Roofs--Missing Components from Downspouts/Gutters.

Severity Defined

Minor: N/A.
Major: Debris around or in a drain is observed with no evidence
of ponding observed.
OR
Drain is damaged but still functions.
Severe: Debris around or in a drain is observed with evidence of
ponding observed.
OR
Damage is such that drain no longer functions.

Comments

Severe: Inspection by roofing specialist is recommended if doubt
of the severity of the condition exists.

Damaged Soffits/Fascia (Roofs)

Soffit fascia and/or associated components are damaged. May
provide visible

[[Page 33680]]

opportunity for water penetration or other damage from natural
elements.

Severity Defined

Minor: Damage to soffit/fascia is visible but no obvious
opportunities for water penetration are observed.
Major: N/A.
Severe: Soffits/Fascia are missing (from where required) or
damaged so that water penetration is visibly possible.

Comments

Severe: Inspection by roofing specialist is recommended if doubt
of the severity of the condition exists.

Damaged Vents (Roofs)

Damaged vents on or extending through the roof surface or
components are damaged and/or missing. Vents may include, but is not
limited to, ridge vents, soffit vents, gable vents, plumbing vents,
or gas vent. (NOTE: This does not include exhaust fans located on
the roof. Exhaust fans are covered under building systems--exhaust
system.)

Severity Defined

Minor: The vents are visibly damaged but do not present an
obvious risk to promote subsequent roof damage.
Major: N/A.
Severe: Vents are missing or visibly damaged to the extent that
subsequent roof damage is possible.

Damaged/Torn Membrane/Missing Ballast (Roofs)

Visible rip or wear in the membrane. Includes punctures, holes,
cracks, blistering, and separated seams.

Note: Includes flashing.

Severity Defined

Minor: N/A.
Major: Ballast has shifted and no longer performs function.
Severe: Visible damage to the membrane with visible signs of
current damage and/or leaks.

Comments

Severe: Inspection by roofing specialist is recommended if doubt
of severity of the condition exists.

Missing/Damaged Components from Downspout/Gutter (Roofs)

Components of the drainage system are visibly missing. The
system includes gutters, leaders, downspouts, splashblocks and drain
openings.

Note: This does not include clogged drains. Refer to Building
Exterior--Roofs--Clogged Drains.

Severity Defined

Minor: Splashblocks are missing or damaged.
Major: N/A.
Severe: Drainage system components are visibly missing or
damaged providing opportunities for damage to the roof, structure,
exterior wall surface, interior, or surrounding grounds.

Missing/Damaged/Shingles (Roofs)

The shingles are missing or damaged which includes, but is not
limited to, cracking, warping, cupping or deteriorated.

Note: A square is defined as 100 square feet.
Severity Defined
Minor: N/A.
Major: Up to 2 squares of surface material or shingles are
missing.
Severe: More than 2 squares of shingles are observed to be
missing from surveyed roofing areas.

Ponding (Roofs)

Evidence of areas of standing water exists.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Evidence of standing water on roof causing potential or
visible damage to roof surface or underlying materials.

Comments

Severe: Inspection by roofing specialist is recommended if doubt
of the severity of the condition exists.

Cracks/Gaps (Walls)

Visible split, separation, or gap in the exterior walls.

Severity Defined

Minor: Crack that is less than \1/8\ inch in width or depth.
Major: Crack that exceeds \1/8\ inch in width or depth. May also
provide opportunities for water penetration.
OR
Pieces, such as numerous bricks, that are separated from the
wall.
Severe: Large crack or gap visibly estimated to exceed \3/8\
inch in width or depth possibly indicating a serious structural
problem.
OR
Crack that is the full depth of the wall and/or provides
opportunity for water penetration.
OR
Wall sections that are broken apart.

Comments

Severe: Request an inspection by a structural engineer if doubt
about severity exists.

Damaged Chimneys (Walls)

The chimney, including the portion extending above the roof
line, has separated from the wall or has cracks, spalling, missing
pieces, or broken sections.

Severity Defined

Minor: N/A.
Major: Surface of chimney is cracking, spalling, or otherwise
showing visible surface damage.
Severe: Part or all of the chimney has visibly separated from
the adjacent wall. Cracked or fallen pieces or sections may
currently be present or there is a risk of falling pieces creating a
safety hazard.

Missing Pieces/Holes/Spalling (Walls)

Deterioration, such as missing pieces, holes or spalling in the
exterior wall surface. May also be attributed to rotting materials;
or, concrete, stucco, or masonry wall is flaking, chipping, or
crumbling.

Severity Defined

Minor: N/A.
Major: Any missing piece, such as, a single brick or section of
siding, or hole.
OR
Deterioration that affects an area up to 8\1/2\'' x 11''.
Severe: Deterioration that causes any reinforcing material (re-
bar) to be exposed.
OR
More than one missing piece, such as a few bricks, or section of
siding or holes that affects an area larger than 8\1/2\'' x 11''.
OR
Any size hole that completely penetrates the exterior wall.

Comments

Severe: Request an inspection by a structural engineer if doubt
about severity exists.

Missing/Damaged Caulking/Mortar (Walls)

Caulking designed to provide weather resistance or mortar is
missing or deteriorated.

Note: This doesn't include caulking relative to doors and
windows as they are covered in other areas. All other caulking, etc.
should be addressed here.

Severity Defined

Minor: Mortar is missing around a single masonry unit.
OR
Deteriorated caulk is confined to less than 12 inches.
Major: Mortar is missing in around more than one contiguous
masonry unit.
OR
Deteriorated caulking is evident in an area longer than 12
inches.
Severe: N/A.

Stained/Peeling/Needs Paint (Walls)

Paint is cracking, flaking, otherwise deteriorated. Water damage
or related problems have stained the paint.

Note: This does not include walls that are not intended to have
paint, such as most brick walls, etc.

Severity Defined

Minor: Visible observations estimate that less than 50% of a
single building exterior wall is affected.
Major: Visible observations estimate that more than 50% of a
single building exterior wall is affected.
Severe: N/A.

Broken/Missing/Cracked Panes (Windows)

Glass pane is broken, missing or cracked.

Severity Defined

Minor: Glass pane is cracked, but no sharp edges are present.
Major: N/A.
Severe: Glass pane is missing or broken.

Damaged/Missing Screens (Windows)

Screen is punctured, torn, is otherwise damaged or is missing.

Severity Defined

Minor: Screen has significant punctures, tears, is otherwise
damaged or is missing.
Major: N/A.
Severe: N/A.

[[Page 33681]]

Damaged Sills/Frames/Lintels/Trim (Windows)

Window sills, frames, sash lintels, or trim are damaged by
decay, rust, rot, corrosion, or other deterioration.

Severity Defined

Minor: N/A.
Major: Damage does not affect the window's intended operation.
Severe: Damage affects the window's intended operation.

Missing/Deteriorated Caulking/Glazing Compound (Windows)

Caulking or glazing compound to provide weather resistance is
missing or deteriorated.

Note: This also includes Thermopane or insulated windows that
have failed.

Severity Defined

Minor: Missing or deteriorated caulk or glazing compound is
confined to small areas with no evidence of damage to the window
and/or surrounding structure.
Major: Missing or deteriorated caulk or glazing compound is
consistently evident for the majority of the window with no evidence
of damage to the window and/or surrounding structure.
OR
2 or more of the windows surveyed have minor deficiencies.
Severe: Evidence of leaks or damage to the window or surrounding
structure.

Peeling/Needs Paint (Windows)

Paint covering the window assembly/trim is cracking, flaking, or
otherwise failing; or window assembly/trim is not painted or is
exposed to the elements.

Note: This does not include windows that are not intended to be
painted.

Severity Defined

Minor: Peeling paint and/or a window in need of paint is observed.
Major: N/A.
Severe: N/A.

Security Bars Prevent Egress (Windows)

Security bars are damaged, constructed or installed, such that
egress is severely limited or impossible.

Note: This does not include windows not designed or intended for
egress.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: The ability to exit through the window is limited by
security bars that do not function properly and, therefore, pose
safety risks.

Deteriorated/Missing Caulking/Seals (Doors)

Sealant and stripping designed to provide weather resistance or
caulking is missing or deteriorated.

Severity Defined

Minor: For a single window, missing or deteriorated caulk is
confined to small areas with no evidence of damage to the door and/
or surrounding structure.
Major: For a single door, missing or deteriorated caulk is
consistently evident for the majority of the door with no evidence
of damage to the door and /or surrounding structure.
OR
2 or more of the doors surveyed have minor deficiencies.
Severe: For at least one door missing or deteriorated caulking
is evident along with evidence of leaks or damage to the door
surrounding structure; or more than half of the total door surveyed
have minor caulking deficiencies.
OR
The seal is missing.

Building Systems Inspectable Items

Items to inspect for ``Building Systems'' are as follows:

Domestic Water
Electrical System
Elevators
Emergency Power
Exhaust System
Fire Protection
HVAC
Sanitary System

Domestic Water (Building Systems)

Portion of the building system that provides potable water
conditioning, heating, and distribution taking its source from
outside the building and terminating in domestic plumbing fixtures.
The system typically consists of water conditioners (filters and
softeners), water heaters, transfer and circulating pumps,
strainers, and connecting piping, fittings, valves, and supports.

Note: This does not include portion of water supply that
connects to the heating and cooling system. Also, the delivery
points of the system such as sinks and faucets in units or common
areas.

This inspectable item can have the following deficiencies:

Central Hot Water Supply Inoperable
Leaking Central Water Supply
Misaligned Ventilation System
Missing Pressure Relief Valve
Rust/Corrosion on Heater Chimney
Water Supply Inoperable
Rust/Corrosion on Central Water Components

Electrical System (Building Systems)

Portion of the building system that safely provides electrical
power throughout the building. Including equipment that provides
control, protection, metering, and service.

Note: This does not include transformers or metering that
belongs to the providing utility. Equipment that is part of any
emergency power generating system. Terminal equipment such as
receptacles, switches, or panelboards that are located in the units
or common areas.

This inspectable item can have the following deficiencies:

Blocked Access/Improper Storage
Burnt Breakers
Evidence of Leaks/Corrosion
Frayed Wiring
Missing Breakers
Missing Covers

Elevators (Building Systems)

Vertical conveyance system for moving personnel, equipment,
materials, household goods, etc.
This inspectable item can have the following deficiency: Not
Operable.

Emergency Power (Building Systems)

Standby/backup equipment intended to supply illumination or
power or both, (battery or generator set) during utility outage.
This inspectable item can have the following deficiencies:
Run-Up Records/Documentation Not Available

Exhaust System (Building Systems)

The system used to primarily exhaust stale air from the
building. Primarily from the kitchen and bathroom areas.

Note: This does not include elements related to the HVAC system.

This inspectable item can have the following deficiencies: Roof
Exhaust Fans Inoperable

Fire Protection (Building Systems)

Building System designed to minimize the effects of a fire. May
include the following: fire walls and doors, portable fire
extinguishers, and permanent sprinkler systems.

Note: This does not include fire detection, alarm, and control
devices.

This inspectable item can have the following deficiencies:

Missing Sprinkler Head
Missing/Damaged/Expired Extinguishers

HVAC (Building Systems)

Portion of the building system that provides ability to heat or
cool the air within the building. Includes equipment such as
boilers, burners, furnaces, fuel supply, hot water and steam
distribution, and associated piping, filters, and equipment. Also
includes air handling equipment and associated ventilation ducting.
This inspectable item can have the following deficiencies:

Boiler/Pump Leaks
Fuel Supply Leaks
General Rust/Corrosion
Gas Fired Unit `` Missing/Misaligned Chimney

Sanitary System (Building Systems)

Portion of the building system that provides for the disposal of
waste products with discharge to the local sewage system. Can
include sources such as domestic plumbing fixtures, floor drains,
and other area drains. Consists of floor drains and traps,
collection sumps, sewage ejectors, sewage pumps, and collection
piping, fittings, valves, and supports.

Note: This does not include site storm drainage. Refer to Site--
Storm Drainage.

This inspectable item can have the following deficiencies:

Broken/Leaking/Clogged Pipes or Drains (Sanitary System)
Missing Drain/Cleanout/Manhole Covers

[[Page 33682]]

Leaking Central Water Supply (Domestic Water)

Water visibly leaking from any water system component. Includes
valve flanges, stems, bodies, hose bibbs or from any domestic water
tank or its pipe or pipe connections.

Note: This includes both hot and cold water.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Water is visibly leaking.

Comments

Severe: If condition is a health and safety concern, it must be
recorded manually. (Includes but not limited to ``Electrical
Hazards''.)

Misaligned Ventilation System (Domestic Water)

The ventilation system on a gas/oil fired water heater is
misaligned.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Any misalignment/damaged which may cause improper or
dangerous venting of exhaust gases.

Missing Pressure Relief Valve (Domestic Water)

Pressure relief valve on central hot water heating system is not
present.

Note: This does not include the pipe from the PRV to the floor.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: No pressure relief valve present.

Rust/Corrosion on Central Water Components (Domestic Water)

The material condition of the equipment and/or associated piping
shows evidence of flaking, discoloration, pitting or crevices.

Severity Defined

Minor: N/A.
Major: Significant formations of metal oxides are visible or a
noticeable pit or crevice has developed.
Severe: Condition has rendered equipment and/or piping
inoperable.

Rust/Corrosion on Heater Chimney (Domestic Water)

The material condition of the water heater chimney shows
evidence of flaking, discoloration, pitting or crevices.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: The water heater chimney shows evidence of flaking,
discoloration, pitting or crevices which may result in holes,
ultimately, allowing leaks of toxic gases from the chimney.

Water Supply Inoperable (Domestic Water)

Water is unavailable at unit or common area faucets.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Running water is unavailable within any area of the
building.

Blocked Access/Improper Storage (Electrical System)

The placing of any object that will delay or prevent access to
any panelboard or main power switch.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: One or more items are placed in front of the building
systems' electrical panel.

Burnt Breakers (Electrical System)

Breakers having carbon on the plastic body, or plastic body is
melted and scarred.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Any signs of carbon residue or breaker is melted and/or
has arcing scars.

Evidence of Leaks/Corrosion (Electrical System)

Liquid stains, rust marks or other signs of corrosion are found
on electrical enclosures or hardware.

Note: Do not address surface rust if it does not affect the
condition of the electrical enclosure.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Any corrosion that affects the condition of the current
carrying components. Stains and/or rust on the interior of
electrical enclosures or evidence of water leaks are present in the
enclosure or hardware.

Frayed Wiring (Electrical System)

Insulation may be frayed, stripped, or removed resulting in a
potentially dangerous condition.

Note: This does not include any wires not intended to be
insulated, such as grounding wires.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Nicks, abrasions or fraying of the insulation.

Comments

Severe: If condition is a health and safety concern, it must be
recorded manually. (Includes but not limited to ``Electrical
Hazards.'')

Missing Breakers (Electrical System)

An open circuit breaker position in a panel-board, main panel
board or other electrical box containing circuit breakers; not
appropriately blanked-off.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Open breaker port.

Missing Covers (Electrical System)

Missing covers on any electrical device box, panel box, switch
gear box, control panel, etc., where visible electrical connections
are exposed.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Cover is missing resulting in exposed visible electrical
connections.

Not Operable (Elevators)

Elevator will not ascend or descend. Door will not open or
close. Door opens without cab being present.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Any elevator that is either inoperable or doors open
without cab present.

Auxiliary Lighting Inoperable (Emergency Power)

Emergency lighting which provides illumination during periods of
power outage.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Auxiliary lighting does not function.

Severity Defined

Minor: N/A.
Major: Current records (within the last 12 months) are lost but
old records demonstrate proper use.
Severe: No records are available.

Roof Exhaust Fans Inoperable (Exhaust System)

The ventilation system to exhaust kitchen and/or bathroom air is
inoperable.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Roof exhaust fan unit is inoperable.

Missing Sprinkler Head (Fire Protection)

Any sprinkler head connected to the central fire protection
system is missing, visibly disabled, blocked, and/or capped.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Any sprinkler head is missing, visibly disabled,
blocked, and/or capped.

Comments

Severe: If condition is a health and safety concern, it must be
recorded manually. (Includes but not limited to ``Hazards.'')

Missing/Damaged/Expired Extinguishers (Fire Protection)

A portable fire extinguisher is not in its proper location, is
damaged or the extinguisher certification has expired.

Note: This includes fire hoses in fire cabinets.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Missing or damaged extinguisher, or expired extinguisher
certificate is observed.

[[Page 33683]]

Boiler/Pump Leaks (HVAC)

Escaping of water/steam from unit casing or system piping.

Note: This does not include fuel supply leaks. See Building
Systems--HVAC fuel supply leaks. Also, don't include steam escaping
from pressure relief valves.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Visible leak is observed.

Comments

Severe: If condition is a health and safety concern, it must be
recorded manually. (Include but not limited to ``Hazards.'')

Fuel Supply Leaks (HVAC)

There is evidence of fuel escaping from a fuel storage tank or
fuel line.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Any leakage of fuel from the supply tank or piping.

Gas Fired Unit--Missing/Misaligned Chimney (HVAC)

The exhaust system on a gas/oil fired unit is misaligned.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Any misalignment which causes improper or dangerous
venting of gases.

General Rust/Corrosion (HVAC)

The material condition of the equipment and/or associated
piping/ducting shows evidence of flaking, discoloration, pitting or
crevices.

Severity Defined

Minor: N/A.
Major: Significant formations of metal oxides are visible or a
noticeable pit or crevice has developed.
Severe: Condition has rendered equipment and/or piping
inoperable.

Broken/Leaking/Clogged Pipes or Drains (Sanitary System)

Any visible leaks in sanitary system components or visibly
clogged drains.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Visible active leaks are observed within or around the
system components. Standing water, puddles, or ponding have occurred
which is indicative of leaks or clogged drains.

Missing Drain/Cleanout/Manhole Covers (Sanitary System)

The protective covers are not present.

Note: This also includes covers observed while walking the site.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Cover is missing.

Comments

Severe: If condition is a health and safety concern, it must be
recorded manually. (Include but is not limited to ``Air Quality'',
``Hazards.'')

Common Areas Inspectable Items

Items to inspect for ``Common Areas'' are as follows:

Basement/Garage/Carport
Closet/Utility/Mechanical
Community Room
Day Care
Halls/Corridors/Stairs
Kitchen
Laundry Room
Lobby
Office
Other Community Spaces
Patio/Porch/Balcony
Pools and Related Structures
Restrooms/Pool Structures
Storage
Trash Collection Areas

Basement/Garage/Carport (Common Areas)

Basement: the lowest habitable story of a building, usually
below ground level. Garage: a building or wing of a building in
which to park a car. Carport: a roof projecting from the side of a
building or free standing, used to shelter an automobile.
This inspectable item can have the following deficiencies:

Ceiling Damaged
Doors Damaged
Floors Damaged
Lighting Damaged/Inoperable
Outlets/Switches Damaged
Smoke Detector Inoperable
Stairs/Hand Railings Damaged
Walls Damaged
Windows Damaged

Closet/Utility/Mechanical (Common Areas)

An enclosed room or closet housing machines and/or equipment
that service the building.
This inspectable item can have the following deficiencies:

Ceiling Damaged
Doors Damaged
Floors Damaged
Lighting Damaged/Inoperable
Outlets/Switches Damaged
Smoke Detector Inoperable
Stairs/Hand Railings Damaged
Walls Damaged
Windows Damaged

Community Room (Common Areas)

Meeting place used by members of a community for social,
cultural, or recreational purposes.
This inspectable item can have the following deficiencies:

Ceiling Damaged
Doors Damaged
Floors Damaged
HVAC System Inoperable
Outlets/Switches
Smoke Detector
Stairs/Hand Railings
Walls Damaged
Lighting Damaged/Inoperable
Windows Damaged

Day Care (Common Area)

Place that provides daytime supervision, training, and medical
services for preschool children or for the elderly.
This inspectable item can have the following deficiencies:

Ceiling Damaged
Doors Damaged
Floors Damaged
HVAC System Inoperable
Lighting Damaged/Inoperable
Outlets/Switches Damaged
Smoke Detector Inoperable
Stairs/Hand Railings Damaged
Walls Damaged
Windows Damaged

Halls/Corridors/Stairs (Common Areas)

Passageway in a building, which organizes its rooms, apartments
and staircases.

This inspectable item can have the following deficiencies:

Ceiling Damaged
Doors Damaged
Floors Damaged
HVAC System Damaged
Lighting Damaged/Inoperable
Outlets/Switches Damaged
Smoke Detector Inoperable
Stairs/Hand Railings Damaged
Walls Damaged
Windows Damaged
Graffiti
Mailboxes Damaged

Kitchen (Common Areas)

A place where food is cooked or prepared. The facilities and
equipment used in preparing and serving food.
This inspectable item can have the following deficiencies:

Ceiling Damaged
Doors Damaged
Floors Damaged
Kitchen
Lighting Damaged/Inoperable
Outlets/Switches Damaged
Smoke Detector Inoperable
Stairs/Hand Railings Damaged
Walls Damaged
Windows Damaged

Laundry Room (Common Areas)

Place where soiled clothes and linens are washed and/or dried.
This inspectable item can have the following deficiencies:

Ceiling Damaged
Doors Damaged
Floors Damaged
HVAC System Inoperable
Laundry Room
Lighting Damaged/Inoperable
Outlets/Switches Damaged
Smoke Detector Inoperable
Stairs/Hand Railings Damaged
Walls Damaged
Windows Damaged

Lobby (Common Area)

A foyer, hall, or waiting room at or near the entrance of a
building.
This inspectable item can have the following deficiencies:

[[Page 33684]]

Ceiling Damaged
Doors Damaged
Floors Damaged
HVAC System Inoperable
Lighting Damaged/Inoperable
Outlets/Switches Damaged
Smoke Detector Inoperable
Stairs/Hand Railings Damaged
Walls Damaged
Windows Damaged

Office (Common Areas)

Place in which business, professional, or clerical activities
are conducted. This inspectable item can have the following
deficiencies:

Ceiling Damaged
Doors Damaged
Floors Damaged
HVAC System Inoperable
Lighting Damaged/Inoperable
Outlets/Switches Damaged
Smoke Detector Inoperable
Stairs/Hand Railings Damaged
Walls Damaged
Windows Damaged

Other Community Spaces (Common Areas)

This inspectable item can have the following deficiencies:

Ceiling Damaged
Doors Damaged
Floors Damaged
HVAC System Inoperable
Lighting Damaged/Inoperable
Outlets/Switches Damaged
Smoke Detector Inoperable
Stairs/Hand Railings Damaged
Walls Damaged
Windows Damaged

Patio/Porch/Balcony (Common Areas)

Covered entrance to a building, usually with a separate roof or
a recreation area that adjoins a unit.
This inspectable item can have the following deficiencies:

Ceiling Damaged
Doors Damaged
Floors Damaged
Lighting Damaged/Inoperable
Outlets/Switches Damaged
Patio/Porch/Balcony
Stairs/Hand Railings Damaged
Walls Damage
Windows Damaged

Pools and Related Structures (Common Areas)

Swimming pools and related structures including fencing, etc.
This inspectable item can have the following deficiencies: Pool
and Related Structures--Damaged/Not Operational.

Restrooms/Pool Structures (Common Area)

A room equipped with a water closet or toilet, tub and/or
shower, sink, cabinet(s) and/or closet. This includes locker rooms
or bathhouses associated with swimming pools.
This inspectable item can have the following deficiencies:

Ceiling Damaged
Doors Damaged
Floors Damaged
HVAC System Inoperable
Lighting Damaged/Inoperable
Outlets/Switches Damaged
Restrooms
Smoke Detector Inoperable
Stairs/Hand Railings Damaged
Walls Damaged
Windows Damaged

Storage (Common Areas)

A room in which items are kept for future use.
This inspectable item can have the following deficiencies:

Ceiling Damaged
Doors Damaged
Floors Damaged
HVAC System Inoperable
Lighting Damaged/Inoperable
Outlets/Switches Damaged
Smoke Detector Inoperable
Stairs/Hand Railings Damaged
Walls Damaged
Windows Damaged

Trash Collection Areas (Common Areas)

Collection areas for trash/garbage common pick-up.
This inspectable item can have the following deficiencies: Trash
Collection Areas.

Electrical--Blocked Access/Improper Storage (Common Areas)

The placing of any object that will delay or prevent access to
any panelboard or main power switch.

Severity Defined

Minor: N/A.
Major: N/A
Severe: One or more items are placed in front of the unit's
electrical panel, impeding accessibility in time of an emergency.

Electrical--Burnt Breakers (Common Areas)

Breakers having carbon on the plastic body, or plastic body is
melted or scarred.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Any signs of carbon residue or breaker is melted and/or
has arcing scars.

Electrical--Evidence of Leaks/Corrosion (Common Areas)

Liquid stains, rust marks or other signs of corrosion are found
on electrical enclosures or hardware.

Note: Do not address surface rust if it does not affect the
condition of the electrical enclosure.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Any corrosion that affects the condition of the current
carrying components. Stains and/or rust on the interior of
electrical enclosures or evidence of water leaks are present in the
enclosure or hardware.

Electrical--Frayed Wiring (Common Areas)

Insulation may be frayed, stripped, or removed resulting in a
potentially dangerous condition.

Note: This does not include any wires not intended to be
insulated, such as grounding wires.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Nicks, abrasions or fraying of the insulation.

Comments

Severe: If condition is a health and safety concern, it must be
recorded manually. (Includes but not limited to ``Electrical
Hazards.'')

Electrical--Missing Breakers (Common Areas)

An open circuit breaker position in a panel-board, main panel
board or other electrical box containing circuit breakers; not
appropriately blanked-off.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Open breaker port.

Electrical--Missing Covers (Common Areas)

Missing covers on any electrical device box, panel box, switch
gear box, control panel, etc., where visible electrical connections
are exposed.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Cover is missing resulting in exposed visible electrical
connections.

Ceiling--Bulging/Buckling (Common Areas)

Ceiling has bowed, deflected, is sagging, or has deviated from
original horizontal alignment.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Bulging, buckling, or sagging is observed.

Comments

Severe: Request an inspection by a structural engineer if doubt
about severity exists.

Ceiling--Holes/Missing Tiles/Panels/Cracks (Common Areas)

Punctures in the ceiling surface. May or may not penetrate
completely. Panels or tiles may be missing or damaged.

Severity Defined

Minor: Small holes or missing tile/panel found in a ceiling,
visually estimated at no larger than a sheet of paper (8\1/2\ x 11
inches). Hole does not fully penetrate into the area above (cannot
see through it).
Major: A hole or missing tile/panel is found which is visually
estimated to be larger than a sheet of paper (8\1/2\ x 11 inches)
but does not fully penetrate into the area above (cannot see through
it).
OR
A crack greater than \1/8\'' wide and a minimum of 11'' long.
Severe: Any hole is found which fully penetrates into the area
above (can see through the hole to upper space).

[[Page 33685]]

Comments

Severe: If condition is a health and safety concern, it must be
recorded manually. (Includes but is not limited to ``Hazards.'')

Ceiling--Needs Paint (Common Areas)

Paint is peeling, cracking, flaking, otherwise deteriorated, or
surface is not painted.

Severity Defined

Minor: Area affected is less than 4 square feet.
Major: Area affected is greater than 4 square feet.
Severe: N/A.

Ceiling--Water Stains/Water Damage/Mold/Mildew (Common Areas)

Visible evidence of water infiltration, mold, or mildew exists.
Damage such as saturation or surface failure may have occurred.

Severity Defined

Minor: For a single ceiling, visible indication of a leak, mold,
or mildew, such as a darkened area, exists over a small area (less
than 4 sq. ft.). Water may or may not be evident. Visual
observations estimate that less than 10% of the ceiling surface area
is affected.
Major: For a single ceiling, visible indication of a leak mold
or mildew, such as a darkened area, exists over a large area (more
than 4 sq. ft.). Water may or may not be evident.
OR
Visual observations estimate that 10% to 50% of the ceiling area
has minor damage.
Severe: Visual observations estimate that a large portion (50%
of its surface area) of one ceiling has been exposed to substantial
saturation or damage due to water, mold, or mildew. Visible cracks,
moist areas, mold, or mildew are evident. The ceiling surface may
have failed.
OR
Cases where visual observations estimate that more than 50% of
the ceiling area shows minor defined signs of damage, stains, mold,
or mildew.

Comments

Severe: If condition is a health and safety concern, it must be
recorded manually. (Includes but not limited to ``Air Quality.'')

Doors--Broken/Missing Glazing/Glass (Common Areas)

The glass and/or compound/structure to support and hold glass or
other materials within a frame are missing or broken.

Severity Defined

Minor: For one or more doors, glazing is inadequate to secure
glass, but door is usable and presents no immediate security risk.
Major: N/A.
Severe: For at least one door, the operation, function, or
security of the door is destroyed by the missing or broken glazing
and/or glass. One door in this condition is sufficient to classify
the door system as severe.

Doors--Damaged Surface (Holes/Paint/Rusting) (Common Areas)

Damage in the door surface that may affect either the surface
protection or the strength of the door, or it may compromise
building security or privacy. Includes holes, peeling/cracking/no
paint, or significant rust.

Note: A restroom, fire door, or entry door impacted is severe.

Severity Defined

Minor: Any one door has either: small holes (less than \1/4\
inch in diameter); cracking/peeling paint; and/or the door or its
components are rusting.
Major: If more than one door has minor surface damage as defined
above.
OR
Any single door that has a hole or holes ranging in size from
\1/4\ inch up to 1 inch diameter.
Severe: Any single door has a hole or holes larger than 1 inch
in diameter or significant peeling/cracking/no paint or rust that
affects the integrity of the door surface.

Doors--Damaged Frames/Threshold/Lintels/Trim (Common Areas)

The frame, header, jamb, threshold, lintels, or trim, is visibly
warped, split, cracked, or broken in some manner.

Severity Defined

Minor: A single door's frame/threshold/lintel and/or trim is
damaged but does not hinder door operation. The damaged door frame
does not prevent door from being locked.
Major: More than one door has the minor damage defined above.
Severe: At least one door is rendered inoperable and/or
unlockable due to damage to the door's frame/threshold/lintel and/or
trim.
OR
Minor damage as defined above affects a restroom, entry, or fire
door.

Comments

Severe: If condition is a health and safety concern, it must be
recorded manually. (Includes but is not limited to ``Hazards.'')

Doors--Damaged Hardware/Locks (Common Areas)

The attachments to a door to provide hinging, hanging, opening,
closing, or security are damaged or missing. Includes locks, panic
hardware, overhead door tracks, springs and pulleys, sliding door
tracks and hangers, and door closures.

Severity Defined

Minor: A single door's hardware, as defined above, is damaged
but does not hinder current door operation. The door functions, is
lockable, and the door's panic hardware is operable.
Major: More than one door has minor damaged hardware as defined
above.
Severe: A single door is rendered inoperable and/or unlockable
due to damage to the door's hardware.
OR
Minor damaged as defined above affects a restroom, entry or fire
door.

Comments

Severe: If condition is a health and safety concern, it must be
recorded manually. (Includes but not limited to ``Hazards.'')

Doors--Deteriorated/Missing Seals (Common Areas)

The seals and stripping around the door(s) designed to provide
fire resistance are damaged or missing.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: For a single door the seals are missing. Seals are
damaged to the point that they no longer serve the intended purpose.

Doors--Missing Door (Common Areas)

Door is absent.

Note: A restroom, entry or fire door impacted is severe.

Severity Defined

Minor: The missing door is not a restroom, entry, or fire door.
Major: Missing doors are not an entry, restroom, or fire door.
They present no hazard and visual observation shows two doors or up
to 50% of the doors are missing.
Severe: The missing door is a restroom, entry, or fire door.
OR
Visual observation estimates more than 50% of the doors are
missing.

Comments

Severe: If condition is a health and safety concern it must be
recorded manually. (Includes but not limited to ``Hazards.'')

Floors--Bulging/Buckling (Common Areas)

Floor has bowed, deflected, is sagging, or has deviated from
original horizontal alignment.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Bulging, buckling, or sagging is observed.

Comments

Severe: Request an inspection by a structural engineer if doubt
about severity exists.

Floors--Floor Covering Damaged (Common Areas)

Damage to the carpet, tiles, wood, sheet vinyl, or other floor
covering.

Severity Defined

Minor: For a single floor, floor covering may have stains,
surface burns, shallow cuts, small holes, tears, loose areas or
exposed seams. The covering is fully functional. Visual observation
estimates that less than 10% of the floor area is affected. Does not
present a safety hazard.
Having minor damage as described above are affected. Visual
observations estimate that 10% to 50% of the floors are affected.
Severe: For a single floor, large sections of the covering are
damaged estimated at more than 50% of the floor area.
OR
Floor covering damage that exposes the underlying material.

[[Page 33686]]

OR
Covering that has failed in most traffic areas.

Comments

Severe: If condition is a health and safety concern, it must be
recorded manually. (Includes but not limited to ``Hazards.'')

Floors--Missing Flooring (Common Areas)

Flooring such terrazzo, hardwood, ceramic tile or other flooring
material is missing.

Severity Defined

Minor: For a single floor small holes in areas of the floor
surface. Visual observations estimate less than 10% of the floors
surveyed are affected. No safety problems exist due to this
condition.
Major: Visual observations estimate 10% to 50% of the floors
have minor holes/damage. No safety problem exists due to this
condition.
Severe: Visual observations estimate more than 50% of the floors
are affected by minor holes/damage; or the holes are sufficient for
safety to be compromised. One concern involving compromised safety
is sufficient to classify the floor system as severe.

Floors--Needs Paint (Common Areas)

For floors that are painted, paint is peeling, cracking,
flaking, or otherwise deteriorated.

Note: This applies to any painted floor surface, typically
concrete.

Severity Defined

Minor: For a single floor, a peeling condition exists. Up to or
less than 50% of the floor is affected.
Major: For a single floor, a peeling condition exists. More than
50% of the floor is affected.
Severe: N/A.

Floors--Rot/Deteriorated Subfloor (Common Areas)

Subfloor has decayed or is decaying.

Severity Defined

Minor: N/A.
Major: Condition is slightly noticeable. Small areas of rot or
spongy flooring are found. Inspection observations estimate less
than 10% of the floors are affected.
Severe: Large areas of rot are readily visible. Application of
weight causes noticeable deflection. Inspection observations
estimate more than 10% of floors are affected.

Comments

Severe: Request an inspection by a structural engineer if doubt
about severity exists.

Floors--Water Stains/Water Damage/Mold/Mildew (Common Areas)

Visible evidence of water infiltration, mold, or mildew exists.
Damage such as saturation or surface failure may have occurred.

Severity Defined

Minor: N/A.
Major: Visible indication of a water stain, mold, or mildew,
such as darkened area, exists over a small area (4 sq. ft. or less).
Water may or may not be evident.
Severe: Visual observations estimate that a large portion of
floor has been exposed to substantial saturation or damage due to
water, mold, or mildew. Visible cracks, mold, moist areas and
flaking are evident. The floor surface may have failed.

Comments

Severe: If condition is a health and safety concern, it must be
recorded manually. (Includes but is not limited to ``Air Quality,''
``Hazards.'')

Lighting Damaged/Inoperable (Common Areas)

Lighting fixture is damaged, inoperable, or missing.

Severity Defined

Minor: N/A.
Major: The permanent lighting fixture is damaged, inoperable or
missing.
Severe: N/A.

Comments

Severe: If condition is a health and safety concern, it must be
recorded manually. (Includes but not limited to ``Electrical
Hazards,'' ``Hazards.'')

Outlets/Switches/Cover Plates--Missing/Broken (Common Areas)

The flush plate used to cover the opening surrounding a switch
or outlet is damaged or does not exist. Switch or outlet is missing.

Severity Defined

Minor: Outlet or switch has broken cover plate which does not
result in exposed wiring.
Major: N/A.
Severe: An outlet or switch is missing.
OR
A cover plate is missing or broken resulting in exposed wiring.

Smoke Detector--Missing/Inoperable (Common Areas)

Smoke detector will not activate, or is missing.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: A single missing or inoperable smoke detector is severe.

Stairs--Broken/Missing Hand Railing (Halls/Corridors/Stairs)

The hand rail is damaged or non-existent.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: The hand-rail for four or more stairs is completely
missing or damaged, loose or otherwise unusable.

Stairs--Broken/Damaged/Missing Steps (Halls/Corridors/Stairs)

The horizontal tread or stair surface is damaged or non-
existent.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Step is broken, damaged or missing.
Mailbox Missing/Damaged (Halls/Corridors/Stairs)
Mailbox does not function properly due to deterioration, damage,
or is absent.

Severity Defined

Minor: Mailbox is damaged, vandalized, or deteriorated, but
functional.
Major: N/A.
Severe: Mailbox is damaged, vandalized, or deteriorated, and as
a result, is not functional.
OR
Mailbox is missing.

Graffiti (Halls/Corridors/Stairs)

Visual observation of a crude, (not recognizable as an art
form), inscription or drawing scratched, painted or sprayed on a
building surface, retaining wall, or fence so as to be seen by the
public.

Note: Do not count full wall murals and similar art forms as
graffiti.

Severity Defined

Minor: Visual graffiti observed in at least one location/area.
Major: Graffiti observed in 2-5 locations/areas.
Severe: Graffiti observed in 6 or more locations/areas.

Walls--Bulging/Buckling (Common Areas)

Wall has bowed, deflected, sagged or has deviated from original
vertical alignment.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Bulging/Buckling or sagging is observed.

Comments

Severe: Request an inspection by a structural engineer if doubt
about severity exists.

Walls--Damaged/Deteriorated Trim (Common Areas)

Cove molding, chair rail, base molding or other decorative trim
is damaged or has decayed.

Severity Defined

Minor: Small areas of deterioration in the trim surfaces. Visual
observations estimate that less than 10% of the wall area surveyed
is affected.
Major: Large areas of deterioration in the trim surfaces. Visual
observation estimate that 10% to 50% in any of the wall area
surveyed is affected.
Severe: Significant areas of deterioration in the wall surfaces.
Visual observations estimate that more than 50% of the wall area
surveyed is affected.

Walls--Damaged (Common Areas)

Punctures in the wall surface. May or may not penetrate
completely. Panels or tiles may be missing or damaged. Does not
include small holes created by hanging pictures, etc.

Severity Defined

Minor: A hole missing tile/panel, or other damage found in a
wall, visually estimated at no larger than 8\1/2\ x 11 inches. Hole
does

[[Page 33687]]

not fully penetrate into the adjoining room (cannot see through it).
Major: A hole missing tile/panel or other damage wall that is
larger than a sheet of paper (8\1/2\ x 11).
OR
A crack greater than \1/8\'' in wide and a minimum of 11'' long.
Severe: A hole of any size is found in one or more walls which
fully penetrates into an adjoining room (can see through the hole).

OR
Two or more walls have major holes.

Walls--Needs Paint (Common Areas)

Paint is peeling, cracking, flaking, otherwise deteriorated.

Severity Defined

Minor: Area affected is less than 4 square feet.
Major: Area affected is greater than 4 square feet.
Severe: N/A.

Walls--Water Stains/Water Damage/Mold/Mildew (Common Areas)

Walls are not watertight. Visible evidence of water
infiltration, mold, or mildew exists. Damage such as saturation or
surface failure may have occurred.

Severity Defined

Minor: For a single wall, visible indication of a leak, mold, or
mildew, such as darkened area, exists over a small area. (less than
4 sq. ft. by visual estimate). Water may or may not be evident.
Major: For a single wall, visible indication of a leak exists
over a large area (visually estimated at more than 4 sq. ft.). Water
is probably evident.
Major: Visual observation estimates that a large portion (more
than 50% of the surface) of one or more walls have been exposed to
substantial saturation or damage due to water, mold, or mildew.
Visible cracks, moisture area, mold and flaking are evident. The
wall surface may have failed. One occurrence of this condition is
sufficient to classify the wall system as severe.
OR
Visual observations estimate that more than 50% of the wall
surface in any one area shows signs of water damage, stains, mold,
or mildew.

Windows--Cracked/Broken/Missing Panes (Common Areas)

Glass or pane is cracked, broken or missing.

Severity Defined

Minor: Cracked window pane is observed.
Major: N/A.
Severe: Glass pane is broken or missing.

Windows--Damaged Window Sill (Common Areas)

The horizontal member of the window that bears the upright
portion of the frame is damaged.

Severity Defined

Minor: Sill is damaged but still present. The inside of the
surrounding wall is not exposed. No impact to window operation or
weather tightness is visually apparent.
Major: Sill is missing or damaged enough to expose the inside of
the surrounding walls and/or compromise its weather tightness.
Severe: N/A.

Windows--Security Bars Prevent Egress (Common Areas)

Security bars are damaged, constructed or installed such that
egress is severely limited or impossible.

Note: This does not include windows not designed or intended for
egress.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: The ability to exit through the window is limited by
security bars that do not function properly and, therefore, pose
safety risks.

HVAC--Gas Fired Unit--Missing/Misaligned Chimney (Common Areas)

The exhaust system on a gas fired unit is misaligned.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Any misalignment which causes improper or dangerous
venting of gases.

HVAC--Inoperable (Common Areas)

The heating, cooling, or ventilation system is inoperable.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: The HVAC does not function, providing neither necessary
heating or cooling as designed. System does not respond when the
controls are engaged.

Comments

Severe: If condition is a health and safety concern, it must be
recorded manually. (Includes but not limited to ``Hazards.'')

HVAC--Noisy/Vibrating/Leaking (Common Areas)

The HVAC distribution components, including fans, are the source
of abnormal noise, unusual vibration, or leaks.

Severity Defined

Minor: N/A.
Major: The HVAC system exhibits or shows signs of abnormal
vibration, other noise or leaks when engaged. The condition does not
prevent the system from providing heating or cooling sufficient to
maintain a minimum temperature range in the major living areas of
the unit.
Severe: N/A.

HVAC--Radiator Covers Missing/Damaged (Common Areas)

Radiator cover is missing, damaged or inoperable.

Severity Defined

Minor: N/A.
Major: Radiator is damaged, impeding proper heating and cooling,
but not creating any type of safety hazard.
Severe: Radiator is missing, damaged or substantially not
installed to burn, fan or other potentially serious hazards.

HVAC--Rusted/Corroded (Common Areas)

The material condition of the equipment and/or associated
piping/ducting shows evidence of flaking, discoloration or pitting.

Severity Defined

Minor: N/A.
Major: Significant formations of metal oxides are visible or a
noticeable pit or crevice has developed.
Severe: Condition has rendered equipment and/or piping
inoperable.

Comments

Severe: If condition is a health and safety concern, it must be
recorded manually. (Includes but not limited to ``Hazards.'')

Call-for-Aid Inoperable (Common Areas)

Call-for-Aid is inoperable.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: System does not function as intended.

Countertops--Missing/Damaged (Common Areas)

A flat work surface in a kitchen often integral to lower cabinet
space is missing or deteriorated.

Severity Defined

Minor: Counter-top surface is discolored; materials have begun
to separate or minor scratching and chipping is present.
Major: Surface shows advanced stage of deterioration and/or
scratching, chipping.
Severe: Countertop working surface is missing or deteriorated
and/or damaged and does not provide a sanitary surface to prepare
food.

Cabinets--Missing/Damaged (Common Areas)

A case, box or piece of furniture with sets of drawers or
shelves, with doors, primarily used for storage, mounted on walls or
mounted on floors.

Severity Defined

Minor: Cabinet is discolored; materials have begun to separate
or minor scratching and chipping is present. Cabinet assembly is
present; up to two cabinets may be only marginally functional.
Major: Several (up to 50%) cabinets are either missing, damaged,
or lacking adequate doors and/or shelves.
Severe: A significant number (more than 50%) of cabinets are
either missing, damaged, or lacking adequate doors and/or shelves.

Dishwasher/Garbage Disposal--Inoperable (Kitchen) (Day Care) (Other
Community Spaces)

A dishwasher or garbage disposal, if provided, does not work.

Severity Defined

Minor: N/A.
Major: The dishwasher or garbage disposal does not work.

[[Page 33688]]

Severe: N/A.

Exhaust Systems--Excessive Grease/Inoperable (Kitchen)

Failure of apparatus to draw cooking exhaust.

Severity Defined

Minor: Accumulation of dirt threatens the free passage of air.
Major: N/A.
Severe: Exhaust fan is inoperable or flue may be completely
blocked based on visual estimation.

GFI--Inoperable (Kitchen)(Restrooms/Pool Structures)

GFI is present and inoperable.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: GFI is present and is found inoperable.

Fencing--Damaged/Not Intact (Pools and Related Structures)

Fencing surrounding the swimming pool was observed to be
damaged.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Any damage that compromises the integrity of the fence.

Comments

Severe: If condition is a health and safety concern, it must be
recorded manually. (Includes but is not limited to ``Hazards.'')

Pool--Not Operational (Pools and Related Structures)

Pool was not in operation during the inspection.

Note: If not operational due to seasonal changes the observation
should still be recorded that the pool was not in operation.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Pool was observed not to be operational.

Lavatory Sink--Damaged/Missing (Restrooms/Pool Structures)

Sink, faucet, or accessories are missing, damaged or inoperable.

Severity Defined

Minor: Presence of extensive discoloration and/or cracks in the
basin. Sink is still usable.

Major: N/A.

Severe: Absence or failure of the sink and/or associated
hardware. Sink is unusable.

Plumbing--Clogged Drains (Kitchen) (Restrooms/Pool Structures)

Water does not drain adequately in shower, sink, tub or basin.

Severity Defined

Minor: Water does not drain freely when stopper is disengaged.
Sink is usable.
Major: N/A.
Severe: Drain is completely clogged or has suffered extensive
deterioration. Sink is not usable.

Plumbing--Leaking Faucet/Pipes (Kitchen) (Restrooms/Pool Structures)

Sink faucet or piping leaks.

Severity Defined

Minor: Leak or drip that is contained by basin. Faucet is
usable.
Major: N/A.
Severe: Faucet leak and surrounding area is adversely affected.
OR
Piping leaks and surrounding area is adversely affected.

Range/Stove--Missing/Damaged/Inoperable (Kitchen)

Unit is absent or damaged.

Severity Defined

Minor: Unit's surface is dented, chipped or scratched. Operation
of doors or drawers is impeded but stove is operational. Burner is
misaligned and flame is not distributed equally. Pilot light is out
on one or more burners.
Major: N/A.
Severe: The unit is missing, or any burners and/or oven is
inoperable.

Refrigerator--Missing/Damaged/Inoperable (Kitchen)

The refrigerator does not perform adequately.

Severity Defined

Minor: Refrigerator has excessive accumulation of ice.
OR
Seals around doors are deteriorated.
OR
Operation of doors or drawers is impeded but refrigerator is
operational.
Major: N/A.
Severe: Refrigerator is missing or does not cool at all.

Sink--Damaged/Missing (Kitchen)

Sink, faucet or accessories are missing, damaged, or inoperable.

Severity Defined

Minor: Presence of extensive discoloration and/or cracks in the
basin. Sink & hardware are still usable for food preparation.
Major: N/A.
Severe: Sink or hardware is missing or is totally unusable for
food preparation.

Dryer Vent Missing/Damaged/Inoperable (Laundry Room)

Inadequate means is available to vent accumulated heat to
outside.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Dryer vent is missing or is visually determined to be
inoperable (blocked). Dryer exhaust is not effectively vented to the
outside.

Baluster/Side Railings Damaged (Patio/Porch/Balcony)

Baluster or side railing on this exterior improvement is loose,
damaged or inoperable, limiting the safe use of this area.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: The baluster and/or side rails enclosing this area are
loose, damaged or missing, impeding the safe use of this area.

Restroom Cabinet--Damaged/Missing (Restrooms/Pool Structures)

Damaged or missing cabinets, vanity tops, drawers, shelves, and
doors to include medicine cabinets and vanities.

Severity Defined

Minor: One or more cabinets/vanities have missing and/or damaged
shelves, vanity tops, drawers, and/or doors, but all cabinets are
fully usable.
Major: N/A.
Severe: One or more cabinets are missing or are not usable for
storage due to their poor condition.

Shower/Tub--Damaged/Missing (Restrooms/Pool Structures)

Shower/tub or components are damaged or non-existent.
Minor: N/A.
Major: Presence of extensive discoloration and/or cracks in the
basin. Shower/tub is usable.
Severe: Absence or failure of the shower, tub, faucets or drains
and/or associated hardware. Shower or tub are unusable for any
reason.

Ventilation/Exhaust System--Inoperable (Restrooms/Pool Structure)

Failure of apparatus to exhaust air.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Exhaust fan is inoperable or restroom window cannot be
opened.

Water Closet/Toilet--Damaged/Clogged/Missing (Restrooms/Pool
Structures)

Water closet/toilet is damaged or non-existent.

Severity Defined

Minor: N/A.
Major: Fixture elements, such as but not limited to the seat,
the flush handle, the cover, etc., are missing or damaged.
Severe: Fractured or broken bowl will not retain water. Fixture
may not exist or a hazardous condition exists. Absence of all
flushing ability due to obstruction or other defect.

Chutes Damaged/Missing Components (Trash Collection Areas)

Structure that is utilized to direct garbage into the
appropriate storage container. Components include but are not
limited to the chute, the chute door.
Note: Do not evaluate the door that leads to the trash room.

Severity Defined

Minor: N/A.
Major: Substantially reduced capacity to dispose of refuse.
Severe: Broken or inadequate collection structure causes garbage
to backup into chutes. Compactors or components have failed.

Unit Inspectable Items

Items to inspect for ``Unit'' are as follows:

[[Page 33689]]

Bathroom
Call-for-Aid
Ceiling
Doors
Electrical System
Floors
Hot Water Heater
HVAC System
Kitchen
Lighting
Outlets/Switches
Patio/Porch/Balcony
Smoke Detector
Stairs
Walls
Windows

Call-for-Aid (Unit)

System to summon help. May be visual, audible, or both. May be
activated manually or automatically when pre-programmed conditions
are met.
This inspectable item can have the following deficiency:
Inoperable

Ceiling (Unit)

The visible overhead structure lining the inside of a room or
area.
This inspectable item can have the following deficiencies:

Bulging/Buckling
Holes/Missing Tiles/Panels
Needs Paint
Water Stains/Water Damage/Mold/Mildew

Doors (Unit)

Means of access to the interior of a unit, room within the unit,
or closet. Doors provide privacy and security, control passage,
provide fire and weather resistance.
This inspectable item can have the following deficiencies:

Damaged Surface Holes/Paint/Rusting
Damaged Frames/Threshold/Lintels/Trim
Damaged Hardware/Locks
Damaged/Missing Screen/Storm/Security Door
Deteriorated/Missing Seals (Entry Only)
Missing Door

Electrical System (Unit)

Portion of the building system that safely provides electrical
power throughout the building. Includes equipment that provides
control, protection, metering, and service.
This inspectable item can have the following deficiency:

Blocked Access to Electric Panel
Burnt Breakers
Evidence of Leaks Corrosion
Frayed Wiring
GFI Inoperable
Missing Breakers
Missing Covers

Floors (Unit)

The visible horizontal surface system within a room or area
underfoot; the horizontal division between two stories of a
structure.
This inspectable item can have the following deficiencies:

Bulging/Buckling Floor
Covering Damage
Missing Flooring
Needs Paint
Rot/Deteriorated Subfloor
Water Stains/Water Damage/Mold/Mildew

Hot Water Heater (Unit)

This inspectable item can have the following deficiencies:

Gas Fired Unit--Missing/Misaligned Chimney
Inoperable Unit/Components
Leaking Valves/Tanks/Pipes
Pressure Relief Valve Missing
Rust/Corrosion

HVAC System (Unit)

System to provide heating, cooling and ventilation to the unit.
This does not include building heating or cooling system
deficiencies such as boilers, chillers, circulating pumps,
distribution lines, fuel supply, etc., OR occupant owned or supplied
heating sources.
This inspectable item can have the following deficiencies:

Inoperable
Noisy/Vibrating/Leaking
Rust/Corrosion
Gas Fired Unit--Missing/Misaligned Chimney
Convection/Radiant Heat System/Covers Missing/Damaged

Kitchen (Unit)

A place where food is cooked or prepared. The facilities and
equipment used in preparing and serving food.
This inspectable item can have the following deficiencies:

Cabinets--Missing/Damaged
Plumbing--Clogged Drains
Plumbing--Leaking Faucets/Pipes
Range/Stove--Missing/Damaged/Inoperable
Refrigerator--Missing/Damaged/Inoperable
Dishwasher/Garbage Disposal--Inoperable
Range Hoods/Exhaust Fans--Excessive Grease/Inoperable
Countertops--Missing/Damaged
Sink--Missing/Damaged

Lighting (Unit)

System to provide illumination to a room or area. Includes
fixtures, lamps, and supporting accessories. This inspectable item
can have the following deficiencies:

Missing/Inoperable Fixture

Outlets/Switches (Unit)

The receptacle connected to a power supply or method to control
the flow of electricity. Includes two and three prong outlets,
ground fault interrupters, pull cords, two & three pole switches,
and dimmer switches.
This inspectable item can have the following deficiencies:

Missing
Missing/Broken Cover Plates

Patio/Porch/Balcony (Unit)

Adjoining patio, porch, or balcony.
This inspectable item can have the following deficiency:

Baluster/Side Railings Damaged

Smoke Detector (Unit)

Sensor to detect the presence of smoke and activate an alarm.
May be battery operated or hard-wired to electrical system. May
provide visual signal, audible signal, or both. Smoke detector must
be located on every floor.
This inspectable item can have the following deficiencies:
Missing/Inoperable

Stairs (Unit)

Series of 4 or more steps or flights of steps joined by landings
connecting levels of a unit. Includes supports, frame, treads,
handrails.
This inspectable item can have the following deficiencies:

Broken/Missing Hand Railing
Broken/Damaged/Missing Steps

Walls (Unit)

The enclosure of the unit and rooms. Materials for construction
include concrete, masonry block, brick, wood, glass block, plaster,
sheet-rock. Surface finish materials include paint, wall-coverings.
This inspectable item can have the following deficiencies:

Bulging/Buckling
Damaged
Damaged/Deteriorated Trim
Needs Paint
Water Stains/Water Damage/Mold/Mildew

Windows (Unit)

Window systems provide light, security, and exclusion of
exterior noise, dust, heat, and cold. Frame materials include wood,
aluminum, and vinyl.
This inspectable item can have the following deficiencies:

Cracked/Broken/Missing Panes
Damaged Window Sill
Deteriorated/Missing Caulking/Seals
Inoperable/Not Lockable
Peeling/Needs Paint
Security Bars Prevent Egress

Bathroom Cabinets--Damaged/Missing (Bathroom)

Damaged or missing cabinets, vanity tops, drawers, shelves, and
doors. Includes medicine cabinets and vanities.

Severity Defined

Minor: Cabinet or vanity has missing and/or damaged shelves,
vanity tops, drawers, and/or doors, but is fully usable.
Major: N/A.
Severe: Cabinet is missing or is not usable for storage due to
its poor condition.

Lavatory Sink--Damaged/Missing (Bathroom)

Basin (sink) that shows signs of deterioration, distress, and/or
is non-existent.

Severity Defined

Minor: Presence of extensive discoloration and/or cracks in the
basin. Sink is still usable.
Major: N/A.
Severe: Absence or failure of the sink and/or associated
hardware. Sink is unusable.

Plumbing--Clogged Drains (Bathroom)

Water does not drain adequately in shower, tub, or basin (sink).

[[Page 33690]]

Severity Defined

Minor: Water does not drain freely when stopper is disengaged;
however, sink or tub is usable.
Major: N/A.
Severe: Drain is completely clogged or has suffered extensive
deterioration. Sink or tub is not usable.

Plumbing--Leaking Faucet/Pipes (Bathroom)

Basin, shower, water closet, or tub faucet and/or associated
pipes leak water.

Severity Defined

Minor: Leak or drip that is contained by basin. Plumbing fixture
is usable.
Major: N/A.
Severe: Leak is steady and surrounding area is adversely
affected.
OR
Piping leaks and surrounding area is adversely affected.

Shower/Tub--Damaged/Missing (Bathroom)

Shower/tub or components are damaged or non-existent.
Note: This does not include Leaks.

Severity Defined

Minor: N/A.
Major: Presence of extensive discoloration and/or cracks in the
basin. Shower/Tub is usable.
Severe: Absence or failure of the shower, tub, faucets or drains
and/or associated hardware. Shower or tub is unusable for any
reason.

Ventilation/Exhaust System--Inoperable (Bathroom)

Failure of apparatus to exhaust air.

Severity Defined

Minor: N/A.
Major: N/A.
Severe: Exhaust fan is inoperable or bathroom window cannot be
opened.

Water Closet/Toilet--D