## Text

DEPARTMENT OF HEALTH AND HUMAN SERVICES
Food and Drug Administration
[Docket No. FDA-2004-N-0451]
Food and Drug Administration Modernization Act of 1997: Modifications to the List of Recognized Standards, Recognition List Number: 063

AGENCY:

Food and Drug Administration, HHS.

ACTION:

Notice.

SUMMARY:

The Food and Drug Administration (FDA or Agency) is announcing a publication containing modifications the Agency is making to the list of standards FDA recognizes for use in premarket reviews (FDA Recognized Consensus Standards). This publication, entitled “Modifications to the List of Recognized Standards, Recognition List Number: 063” (Recognition List Number: 063), will assist manufacturers who elect to declare conformity with consensus standards to meet certain requirements for medical devices.

DATES:

Submit either electronic or written comments on the notice at any time. These modifications to the list of recognized standards are applicable March 20, 2025.

ADDRESSES:

You may submit comments on the current list of FDA Recognized Consensus Standards at any time as follows:

Electronic Submissions

Submit electronic comments in the following way:

•
Federal eRulemaking Portal: https://www.regulations.gov.
Follow the instructions for submitting comments. Comments submitted electronically, including attachments, to
https://www.regulations.gov
will be posted to the docket unchanged. Because your comment will be made public, you are solely responsible for ensuring that your comment does not include any confidential information that you or a third party may not wish to be posted, such as medical information, your or anyone else's Social Security number, or confidential business information, such as a manufacturing process. Please note that if you include your name, contact information, or other information that identifies you in the body of your comments, that information will be posted on
https://www.regulations.gov.

• If you want to submit a comment with confidential information that you do not wish to be made available to the public, submit the comment as a written/paper submission and in the manner detailed (see “Written/Paper Submissions” and “Instructions”).

Written/Paper Submissions

Submit written/paper submissions as follows:

•
Mail/Hand Delivery/Courier (for written/paper submissions):
Dockets Management Staff (HFA-305), Food and Drug Administration, 5630 Fishers Lane, Rm. 1061, Rockville, MD 20852.

• For written/paper comments submitted to the Dockets Management Staff, FDA will post your comment, as well as any attachments, except for information submitted, marked and identified, as confidential, if submitted as detailed in “Instructions.”

Instructions:
All submissions received must include the Docket No. FDA-2004-N-0451 for “Food and Drug Administration Modernization Act of 1997: Modifications to the List of Recognized Standards, Recognition List Number: 063.” Received comments will be placed in the docket and, except for those submitted as “Confidential Submissions,” publicly viewable at
https://www.regulations.gov
or at the Dockets Management Staff between 9 a.m. and 4 p.m., Monday through Friday, 240-402-7500. FDA will consider any comments received in determining whether to amend the current listing of modifications to the list of recognized standards, Recognition List Number: 063.

• Confidential Submissions—To submit a comment with confidential information that you do not wish to be made publicly available, submit your comments only as a written/paper submission. You should submit two copies total. One copy will include the information you claim to be confidential with a heading or cover note that states “THIS DOCUMENT CONTAINS CONFIDENTIAL INFORMATION.” The Agency will review this copy, including the claimed confidential information, in its consideration of comments. The second copy, which will have the claimed confidential information redacted/blacked out, will be available for public viewing and posted on
https://www.regulations.gov.
Submit both copies to the Dockets Management Staff. If you do not wish your name and contact information to be made publicly available, you can provide this information on the cover sheet and not in the body of your comments and you must identify this information as “confidential.” Any information marked as “confidential” will not be disclosed except in accordance with 21 CFR 10.20 and other applicable disclosure law. For more information about FDA's posting of comments to public dockets, see 80 FR 56469, September 18, 2015, or access the information at:
https://www.govinfo.gov/content/pkg/FR-2015-09-18/pdf/2015-23389.pdf.

Docket:
For access to the docket to read background documents or the electronic and written/paper comments received, go to
https://www.regulations.gov
and insert the docket number, found in brackets in the heading of this document, into the “Search” box and follow the prompts and/or go to the Dockets Management Staff, 5630 Fishers Lane, Rm. 1061, Rockville, MD 20852, 240-402-7500.

An electronic copy of Recognition List Number: 063 is available on the internet at
https://www.fda.gov/medical-devices/division-standards-and-conformity-assessment/federal-register-documents.
See section IV for electronic access to the searchable database for the current list of FDA-recognized consensus standards, including Recognition List Number: 063 modifications and other standards-related information. Submit written requests for a single hard copy of the document entitled “Modifications to the List of Recognized Standards, Recognition List Number: 063” to Terry Woods, Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave., Bldg. 66, Silver Spring, MD 20993, 301-796-2503. Send one self-addressed adhesive label to assist that office in processing your request or fax your request to 301-847-8144.

FOR FURTHER INFORMATION CONTACT:

Terry Woods, Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave., Bldg. 66, Silver Spring, MD 20993, 301-796-2503,
CDRHStandardsStaff@fda.hhs.gov.

SUPPLEMENTARY INFORMATION:

I. Background

Section 204 of the Food and Drug Administration Modernization Act of 1997 (Pub. L. 105-115) amended section 514 of the Federal Food, Drug, and Cosmetic Act (FD&C Act) (21 U.S.C. 360d). Amended section 514 of the FD&C Act allows FDA to recognize consensus standards developed by international and national organizations for use in satisfying portions of device premarket review submissions or other requirements.

In the
Federal Register
of September 14, 2018 (83 FR 46738), FDA announced the availability of a guidance entitled “Appropriate Use of Voluntary Consensus Standards in Premarket Submissions for Medical Devices.” The guidance describes how FDA has implemented its standards recognition program and is available at
https://www.fda.gov/regulatory-information/search-fda-guidance-documents/appropriate-use-voluntary-consensus-standards-premarket-submissions-medical-devices.
Modifications to the initial list of recognized standards, as published in the
Federal Register
, can be accessed at
https://www.fda.gov/medical-devices/standards-and-conformity-assessment-program/federal-register-documents.

These notices describe the addition, withdrawal, and revision of certain standards recognized by FDA. The Agency maintains on its website HTML and PDF versions of the list of FDA Recognized Consensus Standards, available at
https://www.fda.gov/medical-devices/standards-and-conformity-assessment-program/federal-register-documents.
Additional information on the Agency's Standards and Conformity Assessment Program is available at
https://www.fda.gov/medical-devices/premarket-submissions-selecting-and-preparing-correct-submission/division-standards-and-conformity-assessment.

II. Modifications to the List of Recognized Standards, Recognition List Number: 063

FDA is announcing the addition, withdrawal, correction, and revision of certain consensus standards the Agency is recognizing for use in premarket submissions and other requirements for devices. FDA is incorporating these modifications to the list of FDA Recognized Consensus Standards in the Agency's searchable database. FDA is using the term “Recognition List Number: 063” to identify the current modifications.

In table 1, FDA describes the following modifications: (1) the withdrawal of standards and their replacement by others, if applicable; (2) the correction of errors made by FDA in listing previously recognized standards; and (3) the changes to the supplementary information sheets of recognized standards that describe revisions to the applicability of the standards.

In section III, FDA lists modifications the Agency is making that involve new entries and consensus standards added as modifications to the list of recognized standards under Recognition List Number: 063.

Table 1—Modifications to the List of Recognized Standards

Old
recognition
No.

Replacement recognition No.

Title of standard
1

Change

A. Anesthesiology

1-153
1-180
NFPA 99:2024 Health Care Facilities Code
Withdrawn and replaced with newer version.

1-154
1-181
ASME PVHO-1-2023 Safety Standard for Pressure Vessels for Human Occupancy
Withdrawn and replaced with newer version.

1-75
1-182
ISO 5362 Fifth edition 2024-07 Anaesthetic and respiratory equipment—Anaesthetic reservoir bags
Withdrawn and replaced with newer version.

1-99
1-183
ASTM G175-24 Standard Test Method for Evaluating the Ignition Sensitivity and Fault Tolerance of Oxygen Pressure Regulators Used for Medical and Emergency Applications
Withdrawn and replaced with newer version.

1-140
1-184
ISO 80601-2-55 Second edition 2018-02 [Including AMD1:2023] Medical electrical equipment—Part 2-55: Particular requirements for the basic safety and essential performance of respiratory gas monitor [Including Amendment 1 (2023)]
Withdrawn and replaced with newer version.

1-143
1-185
ISO 80601-2-79 Second edition 2024-08 Medical electrical equipment—Part 2-79: Particular requirements for basic safety and essential performance of ventilatory support equipment for ventilatory impairment
Withdrawn and replaced with newer version.

1-144
1-186
ISO 80601-2-80 Second edition 2024-08 Medical electrical equipment—Part 2-80: Particular requirements for basic safety and essential
Withdrawn and replaced with newer version.

1-146
1-187
ISO 80601-2-12 Third edition 2023-11 Medical electrical equipment—Part 2-12: Particular requirements for basic safety and essential performance of critical care ventilators
Withdrawn and replaced with newer version.

1-160
1-188
ISO 80601-2-84 Second edition 2023-11 Medical electrical equipment—Part 2-84: Particular requirements for the basic safety and essential performance of ventilators for the emergency medical services environment
Withdrawn and replaced with newer version.

B. Biocompatibility

2-266
2-304
ASTM F2382-24 Standard Test Method for Assessment of Circulating Blood-Contacting Medical Device Materials on Partial Thromboplastin Time (PTT)
Withdrawn and replaced with newer version.

C. Cardiovascular

3-54

ANSI AAMI ISO 7198:2016 Cardiovascular implants and extracorporeal systems—Vascular prostheses—Tubular vascular grafts and vascular patches
Transferred. See 3-144.

3-143
3-193
ISO 12417-1 Second edition 2024-02 Cardiovascular implants and extracorporeal systems—Vascular device-drug combination products—Part 1: General requirements
Withdrawn and replaced with newer version. Extent of recognition.

3-150
3-194
ISO 7199 Fourth edition 2024-09 Cardiovascular implants and artificial organs—Blood-gas exchangers (oxygenators)
Withdrawn and replaced with newer version.

3-157

ANSI AAMI ISO 25539-1:2017 Cardiovascular implants—Endovascular devices—Part 1: Endovascular prostheses
Transferred. See 3-149.

3-159
3-195
ISO 5910 Second edition 2024-07 Cardiovascular implants and extracorporeal systems—Cardiac valve repair devices
Withdrawn and replaced with newer version.

3-166
3-196
ISO 81060-2 Third edition 2018-11 [Including AMD1:2020 and AMD2:2024] Non-invasive sphygmomanometers—Part 2: Clinical investigation of intermittent automated measurement type [Including: AMENDMENT 1 (2020) and AMENDMENT 2 (2024)]
Withdrawn and replaced with newer version. Extent of recognition.

D. Dental/Ear, Nose, and Throat (ENT)

4-97
4-328
ANSI/ADA Standard No. 57-2021 Endodontic Sealing Materials
Withdrawn and replaced with newer version.

4-149

ANSI/ADA Standard No. 39-2006 (R2011) Pit and Fissure Sealants
Withdrawn. See 4-222.

4-251
4-329
ISO 6872 Fifth edition 2024-08 Dentistry—Ceramic materials
Withdrawn and replaced with newer version.

4-272
4-330
ANSI/ADA Standard No. 63-2020 Endodontic Instruments—Auxillary
Withdrawn and replaced with newer version.

4-291
4-331
ISO 28399 Third Edition 2021-03 Dentistry—External tooth bleaching products
Withdrawn and replaced with newer version.

E. General I (Quality Systems/Risk Management) (QS/RM)

No new entries at this time.

F. General II (Electrical Safety/Electromagnetic Compatibility) (ES/EMC)

19-10
19-51
UL 1642 Sixth Edition September 29, 2020 Standard For Safety Lithium Batteries
Withdrawn and replaced with newer version.

19-11
19-52
UL 2054 Third Edition November 17, 2021 Standard For Safety Household and Commercial Batteries
Withdrawn and replaced with newer version.

G. General Hospital/General Plastic Surgery (GH/GPS)

6-406
6-504
ASTM F1862/F1862M-24 Standard Test Method for Resistance of Medical Face Masks to Penetration by Synthetic Blood (Horizontal Projection of Fixed Volume at a Known Velocity)
Withdrawn and replaced with newer version.

H. In Vitro Diagnostics (IVD)

7-189
7-322
CLSI M47 2nd Edition; Principles and Procedures for Blood Cultures
Withdrawn and replaced with newer version.

7-266
7-323
CLSI EP19 3rd Edition A Framework for Using CLSI Documents to Evaluate Clinical Laboratory Measurement Procedures
Withdrawn and replaced with newer version.

7-279
7-324
CLSI M07 12th Edition Methods for Dilution Antimicrobial Susceptibility Tests for Bacteria That Grow Aerobically
Withdrawn and replaced with newer version.

7-280
7-325
CLSI M02 14th Edition Performance Standards for Antimicrobial Disk Susceptibility Tests
Withdrawn and replaced with newer version.

7-292
7-326
CLSI M24S 2nd Edition Performance Standards for Susceptibility Testing of Mycobacteria, Nocardia spp., and Other Aerobic Actinomycetes
Withdrawn and replaced with newer version.

7-317
7-327
CLSI M100 34th Edition Performance Standards for Antimicrobial Susceptibility Testing
Withdrawn and replaced with newer version.

I. Materials

8-393
8-618
ASTM F1350-24 Standard Specification for Wrought 18 Chromium-14 Nickel-2.5 Molybdenum Stainless Steel Surgical Fixation Wire (UNS S31673)
Withdrawn and replaced with newer version.

8-405
8-619
ISO 5832-4 Fourth edition 2024-04 Implants for surgery—Metallic materials—Part 4: Cobalt-chromium-molybdenum casting alloy
Withdrawn and replaced with newer version.

8-406
8-620
ISO 5832-11 Third edition 2024-03 Implants for surgery—Metallic materials—Part 11: Wrought titanium 6-aluminium 7-niobium alloy
Withdrawn and replaced with newer version.

8-435
8-621
ISO 5832-1 Sixth edition 2024-04 Implants for surgery—Metallic materials—Part 1: Wrought stainless steel
Withdrawn and replaced with newer version.

8-476
8-622
ASTM F2004-24 Standard Test Method for Transformation Temperature of Nickel-Titanium Alloys by Thermal Analysis
Withdrawn and replaced with newer version.

8-481
8-623
ASTM F1314-24 Standard Specification for Wrought Nitrogen Strengthened 22Chromium-13Nickel-5Manganese-2.5Molybdenum Stainless Steel Alloy Bar and Wire for Surgical Implants (UNS S20910)
Withdrawn and replaced with newer version.

8-522
8-624
ASTM F2129-24 Standard Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements to Determine the Corrosion Susceptibility of Small Implant Devices
Withdrawn and replaced with newer version.

8-599
8-625
ASTM F1295-24 Standard Specification for Wrought Titanium-6 Aluminum-7Niobium Alloy for Surgical Implant Applications (UNS R56700)
Withdrawn and replaced with newer version.

J. Nanotechnology

No new entries at this time.

K. Neurology

No new entries at this time.

L. Obstetrics-Gynecology/Gastroenterology/Urology (OB-Gyn/G/Urology)

No new entries at this time.

M. Ophthalmic

No new entries at this time.

N. Orthopedic

11-254

ISO 14630 Fourth edition 2012-12-01 Non-active surgical implants—General requirements
Withdrawn with transition. See 5-143.

11-308
11-410
ASTM F3161-24 Standard Test Method for Finite Element Analysis (FEA) of Metallic Orthopaedic Total Knee Femoral Components under Closing Conditions
Withdrawn and replaced with newer version.

11-310
11-411
ASTM F1611-20 (Reapproved 2024) Standard Specification for Intramedullary Reamers
Withdrawn and replaced with newer version.

11-317
11-412
ASTM F3129-24 Standard Guide for Characterization of Material Loss from Conical Taper Junctions in Total Joint Prostheses
Withdrawn and replaced with newer version.

11-327
11-413
ASTM F543-23 Standard Specification and Test Methods for Metallic Medical Bone Screws
Withdrawn and replaced with newer version.

11-333
11-414
ASTM F382-24 Standard Specification and Test Method for Metallic Bone Plates
Withdrawn and replaced with newer version.

11-350
11-415
ASTM F2554-22 Standard Practice for Measurement of Positional Accuracy of Computer-Assisted Surgical Systems
Withdrawn and replaced with newer version.

11-372
11-416
ASTM F2996-24 Standard Test Method for Finite Element Analysis (FEA) of Non-Modular Metallic Orthopaedic Hip Femoral Stems
Withdrawn and replaced with newer version.

11-382
11-417
ASTM F3090-24 Standard Test Method for Fatigue Testing of Acetabular Devices for Total Hip Replacement and Performance Requirements
Withdrawn and replaced with newer version.

O. Physical Medicine

No new entries at this time.

P. Radiology

12-259
12-362
IEC 61674 Edition 3.0 2024-07 Medical electrical equipment—Dosimeters with ionization chambers and/or semiconductor detectors as used in X-ray diagnostic imaging
Withdrawn and replaced with newer version.

12-352
12-363
NEMA PS 3.1-3.20 2024e Digital Imaging and Communications in Medicine (DICOM) set
Withdrawn and replaced with newer version.

Q. Software/Informatics

13-116
13-140
FIRST CVSS v4.0 Common Vulnerability Scoring System version 4.0
Withdrawn and replaced with newer version.

13-18

CLSI LIS03-A Standard Guide for Selection of a Clinical Laboratory Information Management System
Withdrawn.

13-19

CLSI LIS04-A Standard Guide for Documentation of Clinical Laboratory Computer Systems
Withdrawn.

13-20

CLSI LIS05-A Standard Specification for Transferring Clinical Observations Between Independent Computer Systems
Withdrawn.

13-21

CLSI LIS06-A Standard Practice for Reporting Reliability of Clinical Laboratory Information Systems
Withdrawn.

13-22

CLSI LIS07-A Standard Specification for Use of Bar Codes on Specimen Tubes in the Clinical Laboratory
Withdrawn.

13-23

CLSI LIS08-A Standard Guide for Functional Requirements of Clinical Laboratory Information Management Systems
Withdrawn.

13-24

CLSI LIS09-A Standard Guide for Coordination of Clinical Laboratory Services within the Electronic Health Record Environment and Networked Architectures
Withdrawn.

R. Sterility

14-290
14-606
ANSI/AAMI ST24:2024 General-purpose ethylene oxide sterilizers with automated process control and ethylene oxide sterilant sources intended for use in health care facilities
Withdrawn and replaced with newer version.

14-432
14-607
ANSI/AAMI ST58:2024 Chemical sterilization and high-level disinfection in health care facilities
Withdrawn and replaced with newer version.

14-460

ISO 11140-1 Third edition 2014-11-01 Sterilization of health care products—Chemical indicators—Part 1: General requirements
Extent of Recognition.

14-588
14-609
AAMI TIR17:2024 Compatibility of materials subjected to sterilization
Withdrawn and replaced with newer version.

S. Tissue Engineering

No new entries at this time.

1
All standard titles in this table conform to the style requirements of the respective organizations.

III. Listing of New Entries

In table 2, FDA provides the listing of new entries and consensus standards added as modifications to the list of recognized standards under Recognition List Number: 063. These entries are of standards not previously recognized by FDA.

Table 2—New Entries to the List of Recognized Standards

Recognition No.

Title of standard
1

Reference No. and date

A. Anesthesiology

1-189
Anaesthetic and respiratory equipment—Vocabulary
ISO 4135 Fourth edition 2022-01.

1-190
Anaesthetic and respiratory equipment—Heat and moisture exchangers (HMEs) for humidifying respired gases in humans—Part 1: HMEs for use with minimum tidal volumes of 250 ml
ISO 9360-1 First edition 2000-03.

1-191
Anaesthetic and respiratory equipment—Heat and moisture exchangers (HMEs) for humidifying respired gases in humans—Part 2: HMEs for use with tracheostomized patients having minimum tidal volumes of 250 ml
ISO 9360-2 First edition 2001-04.

1-192
Anaesthetic and respiratory equipment—Cuff pressure indication, control and regulation devices
ISO 23371 First edition 2022-05.

B. Biocompatibility

No new entries at this time.

C. Cardiovascular

3-197
Cardiovascular implants—Endovascular devices—Part 4: Application of ISO 17327-1 for coated endovascular devices
ISO 25539-4 First edition 2021-11.

D. Dental/ENT

4-332
Implantable Materials for Bone Filling and Augmentation in Oral and Maxillofacial Surgery—Contents of a Technical File
ANSI/ADA Standard No. 206-2024.

4-333
Dentistry—Endodontic instruments—Part 4: Auxiliary instruments
ISO 3630-4 Second edition 2023-08.

4-334
Dentistry—Amalgam separators
ISO 11143 Second edition 2008-07.

4-335
Dentistry—Single-use cartridges for local anaesthetics
ISO 11499 Third edition 2014-06.

4-336
Dentistry—Powered scaler
ISO 18397 First edition 2016-01.

4-337
Dentistry—Powder jet handpieces and powders
ISO 20608 First edition 2018-04.

4-338
Dentistry—Rotational adaptability test between implant body and implant abutment in dental implant systems
ISO 22683 First edition 2022-05.

E. General I (QS/RM)

5-143
Non-active surgical implants—General requirements
ISO 14630 Fifth edition 2024-09.

F. General II (ES/EMC)

19-53
Medical electrical equipment—Part 4-6: Guidance and interpretation—Voluntary guidance to help achieve basic safety and essential performance with regard to the possible effects of electromagnetic disturbances
IEC TS 60601-4-6 Edition 1.0 2024-04.

G. GH/GPS

6-503
Systems for evacuation of plume generated by medical device
ISO 16571 Second edition 2024-03.

H. IVD

No new entries at this time.

I. Materials

8-626
Standard Test Method for Conducting Rotating Bending Fatigue Tests of Solid Round Fine Wire
ASTM E2948-24.

8-627
Standard Practice for Validating the Additive Manufacturing (AM) Production Process for Medical Devices Produced Using Laser Powder Bed Fusion
ASTM F3604-23.

J. Nanotechnology

No new entries at this time.

K. Neurology

No new entries at this time.

L. OB-Gyn/Gastro/Urology

No new entries at this time.

M. Ophthalmic

No new entries at this time.

N. Orthopedic

11-418
Standard Test Method for Assessment of Intra-operative Durability of Intervertebral Body Fusion Devices
ASTM F3631-24.

11-419
Standard Test Method for Evaluating Suture Anchor Insertion and Pull Displacement Resistance
ASTM F3690-24.

O. Physical Medicine

No new entries at this time.

P. Radiology

12-364
Evaluation and routine testing in medical imaging departments—Part 3-8: Acceptance and constancy tests—Imaging performance of X-ray equipment for radiography and radioscopy
IEC 61223-3-8 Edition 1.0 2024-03.

12-365
Diagnostic X-ray imaging equipment—Characteristics of general purpose and mammographic anti-scatter grids
IEC 60627 Edition 3.0 2013-07.

12-366
Evaluation and routine testing in medical imaging departments—Part 3-6: Acceptance and constancy tests—Imaging performance of mammographic X-ray equipment used in a mammographic tomosynthesis mode of operation
IEC 61223-3-6 Edition 1.0 2020-02.

Q. Software/Informatics

13-141
Health informatics—Device interoperability Part 10701: Point-of-care medical device communication—Metric provisioning by participants in a Service-oriented Device Connectivity (SDC) system
ISO/IEEE 11073-10701 First Edition 2024-09.

R. Sterility

14-604
Sterilization of health care products—Microbiological methods—Part 3: Bacterial endotoxin testing
ISO 11737-3 First edition 2023-06.

14-605
Sterilization of health care products—Radiation—Substantiation of selected sterilization dose: Method VDmaxSD
ISO 13004 First edition 2022-10.

14-608
Microbiological methods—Understanding and use of product bioburden data
AAMI TIR106:2024.

S. Tissue Engineering

No new entries at this time.

1
All standard titles in this table conform to the style requirements of the respective organizations.

IV. List of Recognized Standards

FDA maintains the current list of FDA Recognized Consensus Standards in a searchable database that may be accessed at
https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfStandards/search.cfm.
Such standards are those that FDA has recognized by notice published in the
Federal Register
or that FDA has decided to recognize but for which recognition is pending (because a periodic notice has not yet appeared in the
Federal Register
). FDA will announce additional modifications and revisions to the list of recognized consensus standards, as needed, in the
Federal Register
once a year, or more often if necessary.

V. Recommendation of Standards for Recognition by FDA

Any person may recommend consensus standards as candidates for recognition under section 514 of the FD&C Act by submitting such recommendations, with reasons for the recommendation, to
CDRHStandardsStaff@fda.hhs.gov.
To be considered, such recommendations should contain, at a minimum, the information available at
https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/standards-and-conformity-assessment-program#process.

Dated: March 13, 2025.
P. Ritu Nalubola,
Associate Commissioner for Policy.

[FR Doc. 2025-04711 Filed 3-19-25; 8:45 am]
BILLING CODE 4164-01-P

---

Source: Frix Law Library, https://www.frixlaw.com/law-library/documents/fr%3A2025-04711. Public record. Not legal advice.