DEPARTMENT OF THE INTERIOR
Minerals Management Service
Outer Continental Shelf (OCS) Civil/Criminal Penalties

AGENCY:

Minerals Management Service (MMS), Interior.

ACTION:

Notice summarizing OCS civil penalties paid, January 1, 2003 through December 31, 2003.

SUMMARY:

This notice provides a listing of civil penalties paid January 1, 2002 through December 31, 2002, for violations of the OCS Lands Act. The purpose of publishing the penalties summary is to provide information to the public on violations of special concern in OCS operations and to provide an additional incentive for safe and environmentally sound operations.

FOR FURTHER INFORMATION CONTACT:

Doug Slitor (Program Coordinator), Safety and Enforcement Branch, Engineering and Operations Division, (703) 787-1030.

SUPPLEMENTARY INFORMATION:

The Oil Pollution Act of 1990 (OPA 90) strengthened section 24 of the OCS Lands Act Amendments of 1978. Subtitle B of OPA 90, titled “Penalties,” increased the amount of the civil penalty from a maximum of $10,000 to a maximum of $25,000 per violation for each day of noncompliance. More importantly, in cases where a failure to comply with applicable regulations constitutes or constituted a threat of serious, irreparable, or immediate harm or damage to life (including fish and other aquatic life); property; any mineral deposit; or the marine, coastal, or human environment; OPA 90 provided the Secretary of the Interior (Secretary) with the authority to assess a civil penalty without regard to the requirement of expiration of a period of time allowed for corrective action.

On August 8, 1997 (62 FR 42668), MMS published new regulations implementing the civil penalty provisions of the OCS Lands Act. Written in “plain English,” the new question-and-answer format provides a better understanding of the OCS civil penalty process. In addition, the provisions of the OPA 90 require the Secretary to adjust the maximum civil penalty to reflect any increases in the Consumer Price Index. The new rule increased the maximum civil penalty to $25,000 per day, per violation. Please note, subsequent to publishing the new regulations, MMS made several corrections and amendments, including the appeals procedures. These were published at 63 FR 42711, 8/11/98; 64 FR 9066, 2/24/99; 62 FR 9065, 2/24/99, and 64 FR 26257, 5/13/99.

Between August 18, 1990, and January 2003, MMS initiated 450 civil penalty reviews. Operators have paid 341 civil penalties for a total of $9,353,342 in fines. Sixty-two cases were dismissed, 5 cases were merged, and 44 are under review.

On September 1, 1997, the Associate Director of Offshore Minerals Management issued a notice informing lessees and operators of Federal oil, gas, and sulphur leases on the OCS that MMS will annually publish a summary of OCS civil penalties paid. The annual summary will highlight the identity of the party, the regulation violated, and the amount paid. The following table provides a listing of the penalties paid between January 1, 2002, and December 31, 2002. Please note that the MMS published a direct final rule (5/29/98, 63 FR 29477) that renumbers each section in 30 CFR part 250. A quarterly update of the list, along with additional information related to the renumbering of the regulations, is posted on the MMS worldwide web home page,
http://www.mms.gov.

OCS Civil/Criminal Penalties Program

The goal of the MMS OCS Civil/Criminal Penalties Program is to assure safe and clean operations on the OCS. Through the pursuit, assessment, and collection of civil penalties and referrals for the consideration of criminal penalties, the program is designed to encourage compliance with OCS statutes and regulations.

The following acronyms are used in this table:

ESD (emergency shutdown device);

INC (incident of noncompliance);

LACT (liquid automatic custody transfer);

LSH (level safety high);

LSL (level safety low);

MAWP (maximum allowable working pressure);

NON (notice of noncompliance);

PSH (pressure safety high);

PSHL (pressure safety high/low);

PSL (pressure safety low);

PSV (pressure safety valve);

SDV (shutdown valve);

SSSV (surface-controlled subsurface safety valve);

SSV (surface safety valve).

2002 Civil/Criminal Penalties Summary
[Paid in Calendar Year 2002]

Operator name and Case No.
Violation and date(s)
Penalty paid and date paid
Regulation(s) violated (30 CFR)

The Louisiana Land and Exploration Company—G-2000-047

The master shutdown devices for bad oil pump number 1, bad oil pump number 2 and for 7 wells were bypassed; as well as the pressure safety low on the fuel gas scrubber.
06/14/00-06/14/00

$85,000
01/11/02

250.803(c)(1)

Fairways Specialty Sales & Service, Inc.—G-2001-004

Operator did not conduct an annual crane inspection and the Low Pressure Oil Separator was operating above the MAWP.
06/03/00-10/26/00
09/23/00-10/30/00

$83,000
04/12/02

250.107(a)
250.108

El Paso Production Oil & Gas Company—G-2001-005

The level safety high on the sump tank was bypassed.
10/13/00-10/13/00

$13,000
02/13/02

250.803(c)(1)

Matrix Oil & Gas, Inc.—G-2001-006

INC issued for a hole was in piping caused by corrosion approximately 1 foot down stream of the PSV on the test separator.
09/14/00-09/29/00

$17,000
11/19/02

250.107

Fairways Specialty Sales & Service, Inc.—G-2001-009

Facility was not identified as required and the operator did not correct the violation until 209 days after being cited. Civil Penalty is being pursued as a failure to correct. Facility had corrosion problems including rusty handrails, nuts, bolts, nipples, and valves and the operator did not correct the violation until 213 days after being cited. Civil Penalty is being pursued as a failure to correct.
07/11/00-02/04/01
07/11/00-02/08/01

$84,800
04/12/02

250.154
250.107

Fairways Specialty Sales & Service, Inc.—G-2001-010

Facility was not identified as required and the operator did not correct the violation until 90 days after being cited. Civil Penalty is being pursued as a failure to correct. Facility had corrosion problems including rusty piping, handrails, nuts, bolts, nipples, and valves, and the operator did not correct.
11/06/00-02/01/01
11/06/00-02/05/01

$26,200
04/12/02

250.107
250.154

EEX Corporation—G-2001-013

Pressure safety low on condensate pump bypassed.
12/01/00-12/01/00

$7,500
03/19/02

250.803(c)(1)

El Paso Production Oil & Gas Company—G-2001-015

There were 5 wells where the downhole tubing plug was not tested within the required timeframe.
06/04/00-02/20/01

$7,000
02/01/02

250.804(a)(1)(iii)

Texaco Exploration and Production Inc.—G-2001-017

Inoperable Gas Detection system in the drilling mud returns.
04/17/01-04/17/01

$12,500
01/29/02

250.410(c)(2)(iv)

Amerada Hess Corporation—G-2001-018

ESD (emergency shutdown) station on boat landing was bypassed; the PSHL (pressure safety high/low) on the departing oil pipeline was found bypassed; and the PSV (pressure safety valve) on the bulk oil dual separator was bypassed.
04/11/01-04/11/01
03/31/01-03/31/01
03/31/01-03/31/01

$36,000
04/18/02

250.803(c)(1)
250.803(c)(1)
250.1004(b)(3)

The Louisiana Land and Exploration Company—G-2001-020

The SSSV for Wells Nos. B-1 and B-3 was bypassed.
03/07/01-03/07/01

$20,000
01/11/02

250.803(c)(1)

Texaco Exploration and Production Inc.—G-2001-021

Bypassed manual reset relay for the test separator.
05/21/00-05/21/00

$10,000
01/23/02

250.803(c)(1)

Chevron U.S.A. Inc.—G-2001-024

The surface safety value (SSV) for Well C-7 was bypassed.
06/15/01-06/16/01

$20,000
01/23/02

250.803(c)(1)

BP Corporation North America Inc.—G-2001-025

Level safety low (LSL) for glycol/hydrocarbon separator was found bypassed.
06/12/01-06/13/01

$20,000
01/10/02

250.803(c)(1)

El Paso Production GOM Inc.—G-2001-026

Burner safety low on glycol reboiler was found bypassed. It was not flagged or being monitored at the time.
05/24/01-05/24/01

$12,000
06/05/02

250.803(c)(1)

El Paso Production Oil & Gas Company—G-2001-027

ESD station blocked out of service by a closed manual isolation block valve located on the sub-cellar deck exit stairway to the boating landing.
06/19/01-06/19/01

$17,000
04/15/02

250.803(c)(1)

Chevron U.S.A. Inc.—G-2001-028

Pollution occurred when both the wet oil tank and sump tank carried over. The level safety high (LSH) on the wet oil tank did not shut in the platform as indicated on SAFE chart.
05/25/01-05/25/01
05/25/01-05/25/01

$36,000
01/29/02

250.300(a)
250.802(e)

Denbury Resources Inc.—G-2001-029

A major component of the approved dry chemical firefighting system was inoperable.
05/08/01-05/08/01

$15,000
03/07/02

250.803(b)(8)

Panaco, Inc.—G-2001-030

The ultraviolet (UV) fire detection system for turbine generators was bypassed plus no record of testing the fire detection system from 5/2/99 to 5/2/01.
05/02/99-05/02/01
05/02/01-05/02/01

$151,000
02/12/02

250.804(a)(8)
250.803(c)(1)

NCX Company, Inc.—G-2001-031

The 2″ ball valve for the bypass line, near the fuel gas scrubber shutdown valve (SDV), was in the half-open position rendering the SDV inoperative.
07/11/01-07/11/01

$12,000
04/24/02

250.803(c)(1)

Stone Energy Corporation—G-2001-034

Five barrels of oil polluted the Gulf of Mexico. The pressure safety high/low and independent pressure safety high were bypassed.
07/05/01-07/05/01
07/05/01-07/05/01

$35,000
05/03/02

250.803(c)(1)
250.300(a)

Energy Partners, Ltd.—G-2001-035

The surface safety valve on Well C-1A was bypassed.
07/22/01-07/22/01

$10,000
06/10/02

250.803(c)(1)

Devon Energy Production Company, L.P.—G-2001-036

Operating with an inoperable inlet SDV on the compressor suction scrubber while the compressor remained in service and on production for 76 days.
04/25/01-07/09/01

$15,200
08/12/02

250.803(b)(7)(iii)

Amoco Production Company—G-2001-037

Fuel Gas Scrubber SDV bypassed and PSH nonfunctional.
07/17/01-07/17/01

$15,000
04/02/02

250.803(c)(1)

Energy Resource Technology, Inc.—G-2001-038

The high-pressure freewater knockout separator panel was pinned out of service.
11/30/00-11/30/00

$15,000
06/11/02

250.803(c)(1)

NCX Company, Inc.—G-2001-039

The manual emergency shutdown (ESD) station located on the east production deck stairway exit to the cellar deck was found disconnected from the facility ESD system, and the platform's monitoring gas detection system (ASH) was found bypassed.
07/17/01-07/17/01
07/17/01-07/17/01

$24,500
03/22/02

250.803(c)(1)
250.803(b)(4)

BP Exploration & Oil Inc.—G-2001-040

Rig floor hand injured after receiving a shock from an improperly grounded skid mounted electrical pressure washer.
03/15/01-03/15/01

$23,000
05/09/02

250.114(c)

Apache Corporation—G-2001-041

Surface safety valve (SSV) on Well No. A-5 was found pinned out of service.
07/16/01-07/16/01

$13,000
05/10/02

250.803(c)(1)

GOM Shelf LLC—G-2001-042

The emergency shutdown stations (ESD's) at the southeast and northwest stairways at the +10 deck were discovered inoperable. The ESD's at the southwest and northeast boat landings were also discovered inoperable.
07/24/01-07/24/01

$60,000
09/24/02

250.803(b)(4)

Devon Energy Production Company, L.P.—G-2001-044

The “total system bypass” was found in the bypass position on a slave panel. This bypassed the pressure safety high/low and level safety high on the fuel gas scrubber.
06/27/01-06/27/01

$3,000
06/20/02

250.803(c)(1)

Union Oil Company of California—G-2001-045

The level safety high on the sump tank was bypassed.
07/23/01-07/23/01

$10,000
04/16/02

250.803(c)(1)

Union Oil Company of California—G-2001-047

The emergency shutdown (ESD) station at the boat landing was found blocked out of service.
08/12/01-08/12/01

$5,000
09/11/02

250.803(c)(1)

Union Oil Company of California—G-2002-001

The emergency shutdown (ESD) stations on the northwest, southwest, east, and west boat landings were all bypassed.
09/18/01-09/18/01

$20,000
09/11/02

250.803(c)(1)

Nuevo Energy Company—P-2002-001

Failure to test fire and gas detection systems on required basis (every 3 months); 1 testing period missed. Failure to conduct required monthly testing for flow safety valves on water injection wells for 2 months; 2 testing periods missed.
06/22/01-07/23/01
06/23/01-07/13/01

$6,000
08/08/02

250.804(a)(8)
250.804(a)(8)

Union Oil Company of California—G-2002-003

Pressure safety high/low and level safety high on fuel gas scrubber were found bypassed.
09/25/01-09/25/01
09/25/01-09/25/01

$17,500
09/11/02

250.803(c)(1)
250.803(c)(1)

Fairways Specialty Sales & Service, Inc.—G-2002-004

Oil was observed entering the Gulf of Mexico from two different sources associated with the water clarifier: from the open end of an unapproved 4″ PVC line installed on the water overboard discharge line and extending approximately 20′ into the air, and directly from the water overboard discharge line due to a malfunctioning dump valve.
09/28/01-09/28/01
09/28/01-09/28/01

$42,500
08/20/02

250.802(e)
250.300(a)

J.M. Huber Corporation—G-2002-005

The sump pump was not operational resulting in pollution of crude oil into Gulf waters.
10/30/01-10/30/01
10/30/01-10/30/01

$35,000
08/16/02

250.300(b)(4)
250.300(a)

Fairways Specialty Sales & Service, Inc.—G-2002-006

Emergency shutdown stations at two boat landings and the shutdown valve to the test separator were bypassed.
11/07/01-11/07/01
11/08/01-11/08/01

$28,000
08/20/02

250.803(c)(1)
250.803(c)(1)

Linder Oil Company, A Partnership—G-2002-008

The walkway to the sump tank, handrails on a stairway and +12 walkway, and grating at the wellbay area on the +12 level were not maintained in a safe condition. The walkway and handrails had corroded to the point of separation and the grating had missing sections.
08/28/01-09/20/01

$25,000
09/10/02

250.107

Union Oil Company of California—G-2002-010
Three emergency shutdown stations were bypassed at the +10 deck level. 10/29/01-11/06/01

$15,000
09/11/02

250.803(c)(1)

Kerr-McGee Corporation—G-2002-011

The surface-controlled subsurface safety valves in Wells A-6 & A-6D were bypassed for 11 days.
09/14/01-09/24/01

$66,000
10/22/02

250.803(c)(1)

Vastar Resources, Inc.—G-2002-012

Two emergency shutdown stations were inoperable; one at the boat landing on the F structure and one at the boat landing on the I structure.
12/03/01-12/03/01

$37,000
08/13/02

250.803(b)(4)

Kerr-McGee Oil & Gas Corporation—G-2002-013

Rusty vessel, walkways, stairways, and grating preventing safe operations.
12/21/01-12/21/01

$20,000
10/22/02

250.107

Shell Offshore Inc.—G-2002-014

Flowline pressure-activated relay had a pin inserted in it thereby bypassing the pressure safety high/low for flowline segment FA-2.
10/01/01-10/01/01

$12,000
12/09/02

250.803(c)(1)

Exxon Mobil Corporation—G-2002-015

Secondary sump pump, approved in lieu of level safety high on sump tank, found out of service.
01/10/02-01/11/02

$15,000
09/09/02

250.802(e)

Seneca Resources Corporation—G-2002-016

Surface-controlled subsurface safety valve (SSSV) for Well No. 15 was bypassed and out of service.
12/11/01-12/14/01

$32,000
08/28/02

250.803(c)(1)

J. M. Huber Corporation—G-2002-017

Relay for Well Number 81 Surface Safety Valve pinned out of service.
01/08/02-01/08/02

$7,000
08/27/02

250.803(c)(1)

BP Exploration & Production Inc.—G-2002-018

The oil low level sensor on the heater treater was not tested within the required timeframe (missed 13 monthly tests).
12/13/00-12/03/01

$39,000
09/16/02

250.804(a)(3)

Chevron U.S.A. Inc.—G-2002-019

The gas sales pipeline (KAH 827) did not have secondary over-pressure protection.
11/13/01-11/13/01

$23,000
09/30/02

250.1002(d)

Burlington Resources Offshore Inc.—G-2002-020

The firewater pump was in the manual mode instead of the automatic mode, as required by the approved SAFE chart. The float cell oil pump's shutdown valve was bypassed.
04/20/01-04/20/01
04/20/01-04/20/01

$47,500
12/05/02

250.802(e)
250.803(c)(1)

Remington Oil and Gas Corporation—G-2002-024

Remote BOP control station was found inoperable.
04/18/02-04/18/02

$12,500
12/04/02

250.406(d)(3)

Vastar Resources, Inc.—G-2002-030

Leaking valves causing gas blow by and incorrectly operated Flotation Cell causing gas accumulation resulting in a fire which required an emergency evacuation of personnel and a shut in of the facility.
02/12/02-02/12/02

$20,000
12/10/02

250.107

Conoco Inc.—G-2002-032

Surface-controlled subsurface safety valve for Well A-6 was blocked out of service.
05/08/02-05/08/02

$10,000
11/27/02

250.803(c)(1)

Conoco Inc.—G-2002-035

Surface-controlled subsurface safety valve for Well A-5 was blocked out of service.
05/09/02-05/09/02

$5,000
11/27/02

250.803(c)(1)

Total Penalties Paid: 1/1/02-12/31/02.  54 Cases: $1,448,700.

Dated: May 6, 2003.
E.P. Danenberger,
Chief, Engineering and Operations Division.

[FR Doc. 03-13958 Filed 6-3-03; 8:45 am]