# Joint Appendix Vol III — Kelo v. New London

> Briefs, arguments, decisions, and more.

URL: https://www.frixlaw.com/law-library/documents/brief%3Amicro_IA40385016_0031%3A10

## Record

- **Collection:** Supreme Court brief
- **Document type:** Joint Appendix Vol III
- **Published:** January 1, 2005
- **Citation:** 545 U.S. 469

## Text

C3- 2004

CATICL Ob The cade

Supreme Court of the United States

SUSETTE KELO, THELMA BRELESKY, PASQUALE
CRISTOFARO, WILHELMINA AND CHARLES DERY, JAMES
AND LAURA GURETSKY, PATAYA CONSTRUCTION
LIMITED PARTNERSHIP, and WILLIAM VON WINKLE,

Vv

Petitioners,

CITY OF NEW LONDON, and NEW
LONDON DEVELOPMENT CORPORATION,

@

Respondents.

On Writ Of Certiorari To The
Supreme Court Of Connecticut

eo

JOINT APPENDIX
Volume III, Pages 488 to 735

A

Horton, SHIELDS & Knox, P-C.
WESLEY W. HortTon*

DANIEL J. KRISCH

90 Gillett Street

Hartford, CT 06105

(860) 522-8338

(860) 728-0401 (fax)

WALLER, SMITH & PALMER, PC.
EDWARD B. O’CONNELL

52 Eugene O’Neill Drive
New London, CT 06320
(860) 442-0367

(860) 447-9915 (fax)

Conway & LONDREGAN
THOMAS J. LONDREGAN
JEFFREY T. LONDREGAN
38 Huntington Street
New London, CT 06320
(860) 447-3171

(860) 444-6103 (fax)

Counsel for Respondents
*Counsel of Record

INSTITUTE FOR JUSTICE
WILLIAM H. MELLOR
Scott G. BULLOCK*

DANA BERLINER

1717 Pennsylvania Ave., NW
Suite 200

Washington, DC 20006
(202) 955-1300

(202) 955-1329 (fax)

SAWYER Law Firm, LLC
Scott W. SAWYER

The Jili S. Sawyer Building
251 Williams Street

New London, CT 06320
(860) 442-8131

(860) 442-4131 (fax)

Counsel for Petitioners

OOOO

Petition For Certiorari Filed July 19, 2004
Certiorari Granted September 28, 2004

OOOO S OO
COCKLE LAW BRIEF PRINTING CO (800) 225-6964
OR CALL COLLECT (402) $42 2831 /

| Supreme Cour! US

JOINT APPENDIX TABLE OF CONTENTS

Volume I
Relevant Docket Entries from the Courts below................ 1

EXHIBITS FROM TRIAL HELD IN THE
SUPERIOR COURT, JUDICIAL DISTRICT OF
NEW LONDON IN JULY AND AUGUST, 2001

MAPS

Plaintiffs’ Exhibit TT — Fort Trumbull MDP Area —
New London, Conmecticut ................::ccccccccseeeeeeeeeeeeeeeeeees 3

Plaintiffs’ Exhibit VV — Fort Trumbull MDP Com-
posite Land Use Plan Map 3..............::cccssscsseeeseseeeeseenees 4

Plaintiffs’ Exhibit YY — Fort Trumbull Develop-
ment Site Plan dated October 10, 2000 .....................0000 5

OTHER EXHIBITS
Plaintiffs’ Exhibit B - Representative Statement of

Plaintiffs’ Exhibit I - New London Development
Corporation (NLDC) Board’s Record of Vote and

Resolution dated October 16, 2000 ...................ccccceeeeeeees 9
Plaintiffs’ Exhibit II —- Letter to George Milne from

Claire Gaudiani dated December 15, 1997................... 18
Plaintiffs’ Exhibit PP1 — Email to George Milne

from James Serbia dated October 21, 1998................... 21

Plaintiffs’ Exhibit PP2 - Letter to Dr. Claire
Gaudiani from George Milne, Jr. dated March 8,

ii

JOINT APPENDIX
TABLE OF CONTENTS - Continued

Defendant NLDC’s Exhibit 12 - New London City
Counsel Resolution of January 18, 2000, author-
izing the use of eminent domain.................c0000eees 26

Plaintiffs’ Exhibit HHH - Memorandum from
Developer Marty Jones of Corcoran Jennison to
Joseph E. Corcoran, Gary Jennison, Scott
Dumont, Harry Nash and Eliza Edelsberg dated
GRRTIRGED TR, TRO cccnsscccesnsscsesccssvesncecscsocsccecssccccccummmmnanaes 30

Excerpts from Defendant NLDC’s Exhibit 38 — Fort
Trumbull Municipal Development Plan (MDP) Revised

Administrative Draft, August 1999
* Section 1: Introduction (pgs. 1-1 through 1-11
CIID scncnannncnnscsessnsnntocenntncnnasesensccenesscencesessesssccinammanane 83
* Section 3: Existing Site Conditions (pgs. 3-19
Oe ctenecsesersccnsscassnnmeetesesmenemmmmens 96
¢ Section 5: Proposed Improvements..................00+ 108
¢ Section 9: Administrative Plan Summary ............. 188

¢ Appendix A: Selection of and Rationale for the
Preferred Alternative — Fort Trumbull MDP

¢ Proposed Land Uses Map 5.1...........::::ccceeceeeeseeeees 212
Volumes II and III

Defendant NLDC’s Exhibit 34 - Lraft Environ-
mental Impact Evaluation — dated November 10,

JOINT APPENDIX
TABLE OF CONTENTS - Continued
Page
The following documents have been omitted in the
printing of this Joint Appendix. They may be found in the
Appendix to the Petition for Writ of Certiorari at the
following pages:
Opinion of the Superior Court of Connecticut,
Judicial District of New London, At New London,

Decided March 13, 2002 ................ccccccccceeseeeeeeeees App. 191
Opinion of the Connecticut Supreme Court, De-
SS een App. 1

Order of Connecticut Supreme Court Granting
Motion for Stay of Execution Pending Decision by
the United States Supreme Court, Decided April

Order of the Connecticut Supreme Court Denying
Motion for Reconsideration, Decided April 20,

488

4.0 IMPACT EVALUATION

4.1 Overview of Impacts

source are evaluated for the six land use concept alter-
natives presented in Section 3.0 of this document. This
impact evaluation has been organizationally struc-
tured to be compatible with the existing conditions
inventory presented in Section 2.0 of this document.
Major issues evaluated include (1) consistency with
state and local land use policies for the Fort Trumbull
area; (2) consistency with the Connecticut Coastal
Management Act with respect to water dependency of
waterfront uses; (3) consistency with the project goals
of world class development, economic stimulation, wa-
terfront public access, and the revitalization of down-
town New London; (4) consistency with flood manage-
ment policies; (5) neighborhood relocation impacts; (6)
traffic and parking impacts; and (7) other identified
issues particular to each alternative.

A brief summary of significant positive and negative
impacts of each alternative is presented in Tables 4.1-
1 through 4.1-6. These are described in greater detail
in Sections 4.2 through 4.18 of this document.

A summary that rates the alternatives’ consistency
with project goals and objectives and related impacts is
presented in Table 4.1-7. Designations have been as-
signed for general consistency and impact, without re-
gard to the weight of each area or the degree to which

lective opinion of the project consultant team based on
available data and information, as well as input from
NLDC, state agencies, and various other reviewers. To
assign numerical values to these attributes would be
overly subjective and was therefore not done.

489

The following project goals merit further description:

Complement Pfizer — Consistency of alternatives
with the planned Pfizer facility to the south (and out-
side) of the MDP area is based on whether or not the
land uses would complement the planned develop-
ment. The only alternative which was considered to
be inconsistent was the no action alternative, since it
would result in segmented and disconnected projects,
with no improvements proposed between the two. The
recreation/tourism and residential/commercial alter-
natives were considered neutral in that they would
not be anticipated to detract from the Pfizer facility,
but would not necessarily complement it either. The
business campus and mixed use alternatives were de-
termined to be compatible with and complement the
planned Pfizer facility.

Economic and Financial Considerations — Con-
sistency of alternatives with economic stimulation, job
creation, generation of tax revenues, and creation of
spin-off activity was based on the socioeconomic
analysis presented in Section 4.3 of this document.

Downtown Revitalization - New London is cur-
rently undergoing analysis and evaluation of its
downtown community. Most of these planning pro-
jects are underway and finalized details are not yet
available. The determination of consistency (or lack
thereof) of the alternatives for the Fort Trumbull area
with downtown revitalization is based upon whether
proposed uses would complement or detract from
downtown uses. For instance, a large retail compo-
nent or ferry services would likely duplicate services
which are currently or will soon be provided in the
downtown area, whereas uses in the Fort Trumbull
area that would draw upon or rely on downtown
amenities were considered to be consistent. Residen-
tial uses would be considered neutral or marginally

490

consistent with downtown revitalization in that they
would not likely detract or complement the revitaliza-
tion efforts in downtown New London.

The Fort Trumbull area benefits from its proximity to
downtown New London, which is a major transporta-
tion hub. It is situated near Interstates 95 and 395,
with numerous multi-modal transportation amenities
in the immediate vicinity. Amtrak and Shoreline East
provide daily train service to downtown New London.
Amtrak expects its electrified track to be operational
by the year 2000. Cross Sound Ferry Services, Inc.
provides water transportation to Long Island, Block
Island, and Fisher’s Island. The city has recently in-
vested in a large parking facility located in central
ditionally the Groton/New London Airport is located
across the Thames River in Groton, providing service
to Philadelphia and New York City. South East Area
Transit (SEAT) provides bus service to the southeast
region. Other land uses in downtown New London in-
clude municipal offices, places of worship, business of-
fices, industrial operations, retail, and residential
uses.

Common to Alternatives 2 through 6 is a physical
linkage to downtown New London through the pro-
posed waterfront riverwalk which will ideally make
use of the Amtrak bridge at the entrance to Shaw’s
Cove. Alternately, this linear walkway could take an
inland route, connecting the Fort Trumbull area with
downtown New London.

Resource Impacts - Impacts on resources, regula-
area are also summarized in Table 4.1-7. These are
based upon the analysis presented in Sections 4.2
through 4.16 of this document.

on 491

TABLE 4.1-1
Advantages and Disadvantages of Alternative
No. 1 - No Action

Advantages Disadvantages

¢ Proposed uses at the|* The land uses off NUWC
NUWC site are consistent} would continue to be in dis-
with state and local land) parity with local zoning
use policies for the area. state planning

° Proposed waterfront uses|* Would not meet the project
are water dependent and| goals, objectives, or vision
are consistent with the| for the Fort Trumbull area
CCMA. in total.

* Implementation § would/* Would not complement
result in economic gains,) Pfizer due to the disconti-
and no cost would be in-| nuity of sites.
curred the cit
NLDC. by , Would not have a strong

' itive impact on down-

* No neighborhood reloca- a ‘talizati

tion would be involved. —_
© Public access to the water-
front would not be maximized.
© Would not receive the benefit
of positive roadway and util-
ity improvements proposed]
in the MDP process.
¢ Would not provide aes-
thetic improvements to the!
Fort and Gateway Areas
¢ Flood hazards would not be}
reduced.
* Traffic and parking impacts}
would not be mitigated.
¢ The existing building

492

TABLE 4.1-2

Advantages and Disadvantages of
Alternative No. 2 - Recreation/Tourism

Advantages

© Proposed waterfront uses| ¢

are water dependent and
are consistent with the

¢ Would be compatible with
flood management poli-|*
cies.

¢ Aesthetic and visual im-
provements would result. | ¢

493

TABLE 4.1-3
Advantages and Disadvantages of
Alternative No. 3 - Residential/Commercial

Advantages

Disadvantages

494

TABLE 4.1-4
Advantages and Disadvantages of

Alternative No. 4 -

Business Campus

Proposed waterfront uses
are water dependent and
are consistent with the
CCMA.

Waterfront access would
be provided by the pro-
posed riverwalk.

Will encourage private
investment.

Minimal neighborhood
relocat vn would be nec-
essary.

Aesthetic and visual im-
provements would result.

* Proposed uses are not
onsistent with state and
local land use policies for
the area.

© Would create fewer
number of jobs and tax
revenues as compared
with other alternatives.

¢ Would result in less spin-
off economic activity as
compared to other alter-
natives.

¢ May not have a strong
public funding source.

¢ Would not have a strong
positive impact on down-
town revitalization.

* Would locate residential
uses in a flood hazard
zone (but could be miti-
gated).

¢ Traffic and parking im-
pacts would result (but
could be mitigated).

Advantages

Disadvantages

¢ Proposed uses are consis-
tent with state and local
land use policies for the
area.

¢ Proposed waterfront uses
are water dependent and
are consistent with the
CCMA.

e Waterfront access would
be provided by the pro-
posed riverwalk.

e Would maximize number
of jobs in close proximity
to Pfizer.

¢ Would create highest

number of jobs and tax
revenues as compared to
other alternatives.

* Would result in greatest

spin-off economic activity
as compared to other ai-
ternatives.

¢ Aesthetic and visual im-

provements would result.

e Would be consistent with

and complement down-
town revitalization.

¢ Would locate residential
uses in a flood hazard

zone (but could be miti-| ©

gated).

* Traffic and parking im-
pacts would result (but
could be mitigated).

* 100% neighborhood relo-
cation would result from

implementation of this
alternative (but could be
mitigated).

495

TABLE 4.1-5
Advantages and Disadvantages of
Alternative No. 5 - Mixed Use 1

Advantages

Disadvantages

496

TABLE 4.1-6
Advantages and Disadvantages of
Alternative No. 6 - Mixed Use 2

¢ Proposed uses are consis-
tent with state and local
land use policies for the
area.

e Proposed waterfront uses
are water dependent and
are consistent with the
CCMA.

e Waterfront access would
be provided by the pro-
posed riverwalk.

e Would provide a balanced
mix of land uses.

e Will encourage private
investment.

e Would create jobs and tax
revenues consistent with

project goals.

¢ Would result in spin-off
economic activity consis-
tent with project goals.

e Aesthetic and visual im-
provements would result.

e Would be consistent with
and complement down-
town revitalization.

e Would locate residential
uses in a flood hazard
zone (but could be miti-
gated).

* Traffic and parking im-
pacts would result (but
could be mitigated).

¢ Neighborhood relocation
would result (but could be
mitigated).

Advantages

Disadvantages

¢ Proposed uses are consis-
tent with state and local
land use policies for the
area.

e Would provide a balanced
mix of land uses.

¢ Proposed waterfront uses

~ are water dependent and

are consistent with the
CCMA.

e Waterfront access would
be provided by the pro-
posed riverwalk.

¢ Would create jobs and tax
revenues consistent with

project goals.

¢ Would result in spin-off

economic activity consis-

tent with project goals.

e Will encourage private

investment.

e Would be comparible with

e Aesthetic and visual im-

provements would result.

e Would be consistent with

and complement downtown

¢ 100% neighborhood relo-
cation would result from
implementation of this
alternative (but could be
mitigated).

¢ Traffic and parking im-
pacts would result (but
could be mitigated).

497

TABLE 4.1-7
Fort Trumbull MDP Area Alternatives Impact Summary

IMPACTS

STVIMaLYW snoauvzvul

sion)

o;0

ALITVND uv}

oO

0

9o;oO;0

o;}OoO;0

o};oO;,0

LN@WNOUIANS 1VDISAHd|

o

o

o

LINIWNOUWANS av19071016)

o;o;o0;0;0

TVILNTLOd CUVZVH

+

SADANOSTA VALVM

ONDNVd GNV Dl4sVUL

SIDUNOSIY TVANLIND

SADIAUNTS GNV SELLIMLN DIT

o;o;@;o;o;o

o;o;e@;0o0

SIDUNOSIY IWASIA/DILAALSIV

+

+

SADIANIS/STILITIOVA ALINAWWO

91oO;or1To;}@;oao;e;a;oa

NOILVIO134 aoorsoaHoran)

+

S)IWONOII01909

+

DNINOZ GNV ASN anvil

+

GOALS & OBJECTIVES

NOILVZIMULIATY NMOLNMOG|

Oo

Sasn LNIGNId3aG waived

SSZDOV LNOUTMILVM

ALIAILDV 440-NIdS ALVIN}

GANGAT XVL a1vuana9l

NOtLVIe) aOr

NOLLV'TNWILS DLINONOD A]

uaZldd LNaWa1aWwoo}

LAND USE CONCEPT ALTERNATIVE

Alternative | - No Action

Alternative 2 - Recreation/Tourism

Alternative 3 - Residential/Commercial

Alternative 4 - Business Campes

Alternative 5 - Mixed Use 1

Alternative 6 - Mixed Use 2

O Marginelty Consictent/Minimnal impact (Positive or Negative) © inconsistent/Negstive lepect

lanpect

+

498

4.2 Land Use and Zoning Impacts

4.2.1 Consistency With Relevant Policies and
Programs

Detailed discussions of statewide land use policies,
municipal zoning regulations, and coastal manage-
ment policies are presented in Section 2.1 of this
document. Brief summaries are presented below.

Statewide Land Use Policies

The majority of the Fort Trumbull MDP area has
been designated in the Conservation and Development
Policies Plan for Connecticut as an Urban Area Re-
gional Center. Regional Centers encompass land
areas containing traditional core commercial, indus-
trial, transportation, specialized institutional ser-
vices, and facilities of intertown significance.

State policy seeks to concentrate economic develop-
ment to the extent possible in major urban centers,
promoting infill development and intensification
where appropriate. It is also intended to promote sta-
bility of urban communities and to support staged,
orderly growth of urban development. The goals and
objectives of the statewide plan are used to assess the
consistency of proposed actions with state policy.
State actions (including projects which are funded in
whole or in part with state money) that influence the
form and location of development or conservation be-
cause of investments in infrastructure, real property,
physical facilities, and human services should con-
form to this strategy.

Pertinent goals of regional centers include revitaliza-
tion of the economic base, revitalization of the quality
of life for urban area residents, and economic devel-
opment assistance emphasizing site cleanup, land

499

assembly, structural rehabilitation, and the location
of labor-intensive businesses to revitalize the eco-
nomic base. Priority should be given to. infrastructure
proposals, new product development and facilities for
start-up firms, location of appropriate state facilities
within urban areas, promotion of recreational uses of
urban rivers, and development of heritage parks.

Regional Land Use Goals and Objectives

In 1997, the Southeastern Connecticut Council of
Governments (COG) published their Regional Conser-
vation and Development Policy Guide for Southeast-
ern Connecticut. The following major land use goals
and objectives have been identified for the region.

Minimizing the risks of high unemployment and over-
dependence on a single industry has been identified
by the COG as a major issue of concern. Their goal is
a restructuring the regional economy in order to pro-
vide a balanced and diversified economic base
through the creation of development opportunities.
Improved coordination between the various entities
having primary responsibilities with respect to eco-
nomic development has been cited as the major objec-
tive in achieving this goal.

Developing a transportation system that provides ac-
cess to regional resources for both residents, region-
ally employed, and visitors is also a key issue to the
Southeastern Connecticut COG’s planning efforts.
The intent is to balance needs via several objectives
outlined in the regional! plan, including:

* coordination of policies among key transportation

stakeholders;

* protection of natural and cultural resources during
new system development;

500

* recognition of fiscal constraint;

* expansion of intermodal links; and,

¢ development of alternative modes of transporta-
destrian paths, and light trails.

Additionally, provision of a public utility infrastruc-

ture system that balances the needs and protection of

the region’s population and resources is also a high

priority. It is intended that development and expan-

sion be focused within the region’s core. Objectives

identified for meeting this goal include the following:

* maintenance and improvement of public facilities
such as water, sewer, and solid waste facilities;

* improved coordination between various utilities
and authorities; and,

* encouragement of high density development in ar-

eas suitable to service.

Municipal Zoning Regulations

There is currently a disparity between land use and
zoning in the Fort Trumbull MDP area. Three mu-
nicipal zones occur within the project area. These are
Waterfront Commercial/Industrial (WC-I), Waterfront
Development District (WD), and General Commercial
District (C-I). As would be expected, the majority of
waterfront property is zoned WC-I and WD, with the
interior parcels zoned C-l. There are no residential
zones within the MDP boundary.

Municipal zoning can be modified as part of the MDP
process. However, the Fort Trumbull area has been
targeted for renewal and revitalization for many

501

years and the current zoning reflects the historic
planning philosophy of the city.

Consistency of Program Elements with the
Connecticut Coastal Management Act Policies

Coastal management policies, statutes, and regula-
tions give highest priority and preference to uses and
facilities which are dependent upon proximity to the
water or the shorelands immediately adjacent to ma-
rine and tidal waters. Water-dependent uses are de-
fined by the CCMA to be those uses which:
require direct access to, or location in, marine or
tidal waters and which therefore, cannot be lo-
cated inland, including but not limited to: mari-
nas, recreational and commercial fishing and
boating facilities, finfish and shellfish processing
plants, waterfront dock and port facilities, ship-
— yards and boat building facilities, water-based
recreational uses, navigation aides, basins and
channels, industrial uses dependent upon water-
borne transportation or requiring large volumes
of cooling or process water which cannot rea-
sonably be located or operated at an inland site
and uses which provide general public access to
marine or tidal waters [C.G.S. Section 22a-
93(16)).

Numerous proposed waterfront uses have been re-
viewed for consistency with the CCMA with respect to
water dependency, since these uses are common to
numerous alternatives. Other aspects of CCMA con-
sistency are addressed under their individual topics
in this section of the document (i.e., flood control. bio-
logical resources, etc.). Moving from south to north
along the perimeter of the peninsula, the following
waterfront uses are proposed:

502

Riverwalk - A proposed riverwalk would follow the
perimeter of the peninsula. This feature is intended to
encourage public access to a water resource that has
been unavailable to the general public for many dec-
ades. The riverwalk is proposed to be located primar-
ily in state designated preservation areas, consistent
with policies which are intended to discourage inten-
sive development in these areas. Other uses, such as
the proposed hotel site, residential, and office uses
that are proposed in the various alternatives would
occur landward of the riverwalk, thus providing pub-
lic access directly adjacent to the waterfront. This
philosophy is consistent with the CCMA and with re-
cent Department of Environmental Protection ap-
provals.

Regional Water Pollution Control Facility - Sew-
age treatment disposal is water dependent because of
the need for a receiving waterbody for the large vol-
ume of treated wastewater effluent. The regional
WPCF has been located along the Thames River in
New London since 1929. The only anticipated modifi-
cations are related to improvements to odor control
and aesthetics. No land use or zoning changes are

proposed.

State Park - The CCMA encourages public access to
the waters of Long Island Sound by expansion, devel-
opment, and effective utilization of state-owned rec-
reational facilities within the coastal area that are
consistent with sound resource conservation proce-
dures and constitutionally protected rights of private
property owners. The development of the proposed
Fort Trumbull State Park is therefore consistent with
CCMA policy.

Navy/Coast Guard Facilities - These are existing
operations which are located on the NUWC property
waterfront. These would remain unchanged in their

503

nature. Water dependency is integral to these two or-
ganizations.

Waterfront Related Commercial/Columbia Cove
Area - Two areas along the peninsula perimeter have
been designated as water related or waterfront com-
mercial. These are currently occupied in part by the
Fort Trumbull Marina and the New London Seafood
Distributors. Ongoing water-dependent uses are pro-
posed under all alternatives, either as rehabilit .ed
existing facilities or new water-dependent facilities.

4.2.2 Alternative No. 1 - No Action

Alternative 1 assumes change only to the NUWC
property. This area is currently zoned as a Waterfront
Commercial/Industrial District. Current land use is a
vacant naval base facility, with limited activities.
Land uses and zoning off the NUWC property would
reflect current conditions.

The majority of the NUWC property is designated as
a regional center in the Conservation and Develop-
ment Policies Plan for Connecticut. The fringes of this
land mass are classified as either Conservation or
Preservation areas, presumably due to their flood
prone nature immediately adjacent to the Thames
River.

The proposed land uses at the NUWC site under this
alternative include a 16-acre state park, an area iden-
tified as municipal maritime conveyance, and public
sale for business office uses. These are consistent with
local zoning classifications as well as regional and
statewide planning documents.

‘he coastal management regulations and guidelines
give high priority and preference to uses and facilities
which are dependent upon proximity to the water or

504

the shorelands immediately adjacent to marine and
tidal waters. A state park and ferry terminal would
likely be viewed by the Department of Environmental
Protection as water-dependent land uses. The pro-
posed business/office use is located inland from the
waterfront.

4.2.3 Alternative No. 2 - Recreation/Tourism

The Recreation/tourism alternative includes an ex-
panded state park and other recreational amenities in
the Fort and NUWC portions of the MDP area, along
with several water-related and waterfront commercial
uses. Office and retail uses are concentrated in the
Gateway Area, west of the Amtrak rail line and away
from the Thames River waterfront.

Although recreational facilities offer positive benefits
with respect to public use and public access to the wa-
terfront, they do not promote the overall goals and ob-
jectives of local, regional, or statewide planning
policies and philosophies. This issue alone may not
preclude development as proposed under this alterna-
tive. However, it is a significant factor in evaluating
its consistency with pertinent land use planning poli-
cies. Office and retail uses, proposed in the interior
Gateway Area, are consistent with local, regional, and
statewide policies.

4.2.4 Alternative No. 3 - Residential/Commercial

The proposed uses under this alternative, particularly
those east of the Amtrak railroad, are less intensive
than existing land uses or that which is allowed un-
der current zoning regulations. yo ee
dential use does not promote local, regional, or

statewide planning policies and philosophies and does
not meet the identified objectives and goals which are

505

used to assess consistency of a proposed action in ur-
ban regional centers. Likewise, zoning in the project
area has not been specifically designated for residen-
tial uses. However, similar to Alternative 2, this issue
alone may not preclude development as proposed un-
der this alternative.

The proposed marina/waterfront commercial and wa-
ter-related commercial uses east of the railroad line
are in keeping with state land use planning policies
and local zoning regulations. Similarly, commercial
and retail uses in the Gateway Area are consistent
with the same.

4.2.5 Alternative No. 4 - Business Campus

The majority of land uses associated with the busi-
ness campus scenario are consistent with statewide
planning policies and with local zoning regulations.
The Gateway Area provides a mix of office and retail
uses, with a small amount of residential uses on the
west side of Howard Street.

4.2.6 Alternative No. 5 - Mixed Use 1

This alternative provides a more balanced mix of uses
in the MDP area. Although residential uses are not
explicitly encouraged in regional centers, the area of
residential use in the Fort and NUWC areas is offset
by the concentrated office/incubator uses in the
Gateway Area. The business office. retail, and ho-
tel/conference center uses are consistent with state-
wide policies and local zoning regulations.

506

4.2.7 Alternative No. 6 - Mixed Use 2

This alternative is similar to Alternative 5 in that it
provides a balanced mix of uses without a dispropor-
tionate amount of residential land uses. The Gateway
Area supports a strong office/incubator use to offset
the residential use in the Fort Area. The expanded
Hotel/Conference Center is better suited to meet eco-
nomic goals. These latter uses are consistent with
statewide policies and local zoning regulations.

Socioeconomic Impacts

Key socioeconomic impacts have been estimated for
each of the six alternatives. Included in the impact
analysis is a review of the potential for job creation,
including direct jobs, indirect jobs, and construction
employment. An estimate of the net property tax gain
is also presented for each alternative, which includes
the projected decline in valuation associated with
demolition of existing structures, as well as the pro-
jected increase in valuation associated with the con-
struction of new facilities. A discussion of the
economic costs and benefits is also presented for each
alternative.

4.3.1 Methodology

In order to estimate the tax impacts associated with
each of the alternative land use plans, several sources
of information were utilized. The estimated current
value of facilities in the study area is based on indi-
vidual building assessments, as provided by the New
London assessor’s office. The level of new construction
activity for each alternative is as presented in Section
3.0 of this document. Construction costs for each type
of facility were developed based on construction cost
data provided by the Marshall & Swift Valuation

507

Service, a well known construction cost estimating
guide. These construction cost estimates serve as the
basis for estimating property tax revenues for the de-
velopment alternatives.

The baseline estimates for jobs within the MDP area
(as well as housing units and occupancy) are based on
windshield surveys of the area and on information
gathered through a review of property tax cards pro-
vided by the New London assessor’s office. The study
area was toured on several occasions to determine oc-
cupancy and to compare field observations with in-
formation provided by the assessor’s office.

Estimates of potential direct employment are based
on multipliers provided by the Urban Land Institute
(ULI. ULI tracks development trends throughout the
United States and has estimated ranges of the square
footage required for each employee by industry. Some
of the key components of this information are in-
cluded in Table 4.3-1.

TABLE 4.3-1
Square Footage Per Employee by Industry

650
108,900 174,240
500 2,000

=.
250

2.9 rooms per
employee

2.0 rooms per
employee

Source: Urban Land Institute
‘Although ULI does not track hotels as a separate cate-
gory, information for New London has been developed
based on data obtained from the U.S. Bureau of the

Census.

508

These figures have been used to create a range of di-
rect employment for each alternative, based on the
build-out estimates presented in Section 3.0. In order
to estimate the indirect or induced employment for
each industry, the findings of the U.S. Department of
Commerce’s Regional Input-Outp it Modeling System,
known as RIMS II, were utilized. The RIMS II model
calculates induced employment by industry for each
state. Indirect or induced employment is created as
workers (direct jobs) spend their earnings in the re-
gional economy for food, clothing, housing, automo-
biles, etc. As these earnings are “recycled” through
the economy, additional jobs are created at food
stores, clothing stores, and the like. The key Con-
necticut multipliers used in this analysis are summa-

rized in Table 4.3-2.

TABLE 4.3-2
RIMS II Multipliers by Land Use Category

Source: U.S. Department of Commerce

509

As illustrated in Table 4.3-2, every direct job created
in the retail sector creates an additional 0.4992 jobs
elsewhere in the economy. The higher multipliers as-
sociated with new office development are related to
the nature of the development associated wit> Pfizer
and the generally higher multiples of R&D ane »«nu-
facturing operations.

Estimates of construction jobs associated with new
development in the study area are based on the pro-
jected construction costs for each facility, as deter-
mined through the Marshall & Swift Valuation
Service. Based on the total construction cost for each
land use alternative, total construction wages have
been estimated at 45% of construction costs. Using
the average construction wages for southeastern
Connecticut of $38,388, as provided by the Connecti-
cut Department of Labor, the number of person-years
of construction employment associated with each land
use alternative can be estimated. For example, if con-
struction wages are estimated to be $5,000,000, a to-
tal of 130.25 person-years of construction employment
would be created at an average wage of $38,388.

It is important to note that all financial information
contained in this document is stated in 1998 dollars.
No allowance has been made for inflation or the tim-
ing of revenues and/or expenses.

4.3.2 Alternative No. 1 - No Action

Alternative 1 is referred to as the No Action alterna-
tive. However, this name is somewhat misleading,
since the implementation of this alternative includes
creation of a state park on a portion of the former
U.S. Navy Undersea Warfare Center (NUWC) site as
well as private development of approximately 380,000
square feet of non-residential facilities at NUWC.

510

Job Creation

The implementation of this alternative is anticipated
to create between 1,080 and 1,779 direct jobs. The
majority of these jobs (950 to 1,520) are related to the
reuse of the former NUWC facilities by private sector
entities. The occupancy of an existing under-utilized
office building accounts for an additional 126 to 253
jobs. The remaining jobs are associated with the crea-
tion of the state park. No existing jobs are expected to
be lost under this alternative, with the exception of
the NUWC caretaker staff, estimated to be between
10 and 15. Additional indirect jobs are estimated to be
between 802 and 1,321. This brings the total number
of net new direct and indirect jobs associated with
this alternative to between 1,872 and 3,085.

Tax Revenue Created/Lost

The implementation of this alternative will add new
property to the city’s tax base in the form of the for-
mer NUWC property, which was tax-exempt due to
federal government ownership. Based on an analysis
of properties within the study area, the average prop-
erty assessment is estimated to be $26.00 per square
foot of building area. Using the estimated 380,000
square feet of facilities at NUWC which would be de-
veloped, the city’s tax base would increase by $9.88
million. Using the tax rate of $27.30 per $1,900 of
valuation, property tax revenue for the City of New
London would increase by approximately $270,000.

4.3.3 Alternative No. 2 - Recreation/Tourism

The development program of Alternative 2 is summa-
rized in the Table 4.3-3.

511

TABLE 4.3-3
Development Program - Alternative 2 -

Recreation/Tourism
Land Use Programmed Development
State Park 30 Acres
Columbia Cove Area 80 — 100 Slips
Water-Related Commercial 25,000 — 30,000 SF
otel 80 Rooms
ation Center 25,000 SF
useum(s) 55,000 — 70,000 SF
ce (Existing) 50,500 SF
ce/Incubator 80,000 SF
tail 20,000 SF
D/Office 5,000 SF
aterfront Commercial 25,000 SF

Based on the identified development program, the
projected job creation associated with this alternative
has been estimated. Direct job creation is projected to
be between 506 and 1,019. Due to the density of em-
ployment, office uses contribute the largest number of
jobs, accounting for 339 jobs under the low estimate
and 598 under the high estimate. Table 4.3-4 provides
the estimated job creation by land use category.

512

TABLE 4.3-4
Estimated Range of Direct Employment -
Alternative 2 - Recreation/Tourism
— Low Estimate High Estimate
ployment Employees | Employees
tate Park 8 12
lumbia Cove Area 1 5
ater-Related Commercial 46 120
27 40
tion Center 13 50
useum(s) 4 14
ce (Existing) 126 253
ce/Incubator 200 320
31 80
D Office 13 25
aterfront Commercial 38 180
506 1,019 a

Source: Urban Land Institute and RKG Associates, Inc.

As an offset to the jobs created under this alternative,
it is necessary to subtract the existing jobs in the
study area. It is estimated that 148 to 222 people cur-
rently work within the MDP area. Eliminating these
jobs brings the net gain from this alternative to be-
tween 358 and 797 jobs.

Additional indirect jobs will also be created in the re-
gional economy, based on the recirculation of wages
and purchases through the economy. It is estimated
that between 337 and 659 indirect jobs will be cre-
ated, as detailed in Table 4.3-5.

513

TABLE 4.3-5
Estimated Range of Indirect Employment -
Alternative 2 - Recreation/Tourism

Land Use Category
tate Park 4 6
umbia Cove Area 1 3
ater-Related Commercial 23 60
otel 15 22
tion Center 7 27
useum(s) 2 8
(Existing) 94 188
ce/Incubator 149 238
15 40
D Office 9 19
aterfront Commercial 19 50
337 659

The construction of new facilities in the study area
will also generate additional employment in the form
of short-term construction jobs. Implementation of
this alternative is expected to result. in between $28.2
and $58.1 million in new construction within the
area. Assuming that 45% of this cost is for wages, be-
tween $12.7 million and $26.1 million in construction
wages will be paid out. Using the average construc-
tion wage of $38,388 for the region, 331 to 681 person-
years of construction employment will be created.

Tax Revenue Created/Lost

The implementation of this alternative is expected to
generate between $28.2 and $58.1 million in new con-
struction activity. The projected construction costs are
detailed in the Table 4.3-6. -

mr eee

Source: Marshall & Swift Valuation Service and RKG
Associates, Inc.

Assuming that these facilities are assessed at an av-
erage of 70% of their construction cost, the New Lon-
don tax base would expand by between $19.8 million
and $40.7 million. However, the demolition of existing
structures in this area must also be accounted for.
Approximately $6 million in existing tax base will be
eliminated to implement this plan, making the net in-
crease in the tax base between $13.8 million and
$34.7 million. This translates into a net increase in
property tax revenues of between $375,000 and
$950,000.

515

43.4 Alternative No. 3 - Residential/Commercial

The development program of Alternative 3 is summa-
rized in the Table 4.3-7.

Based on the identified development program, the
projected job creation associated with this alternative
has been estimated. Direct job creation is projected to
be between 335 and 710. Office uses contribute the
largest number of jobs. accounting for 376 jobs under
the low estimate and 398 under the high estimate.
Table 4.3-8 provides the estimated job creation by
land use category.

Source: Urban Land Institute and RKG Associates, Inc.

As an offset to the jobs created under this alternative,
it is necessary to subtract the existing jobs in the
study area. It is estimated that 148 to 222 people cur-
rently work within the study area. Eliminating these
jobs brings the net gain from this alternative to be-
tween 187 and 488 jobs.

Additional indirect jobs will also be created in the re-
gional economy, based on the recirculation of wages
and purchases through the economy. It is estimated
that between 220 and 452 indirect jobs will be cre-
ated, as detailed in Table 4.3-9.

517

TABLE 4.3-9
Estimated Range of Indirect Employment -
Alternative 3 - Residential/Commercial

= Indirect Employment
d Use Category Low Estimate

tate Park 2 3
olumbia Cove Area 1 3
ater-Related Commercial 23 60
tdoor Recreation Area 0 1
ce (Existing) 94 188
ce/Incubator 56 89
tail 15 40
D Office 9 19
aterfront Commercial 19 50
220 452

Source: U.S. Department of Commerce and RKG Associ-

ates, Inc.

+618
TABLE 4.3-10
Estimated Construction Costs -
Alternative 3 - Residential/Commercial
= a

d Use Category Low Estimate
tate Park $3,200,000 | $12,000,000
olumbia Cove Area $450,000 $750,000
ater-Related Commercial $1,855,500 $2,941,800
utdoor Recreation Area $105,000 $393,750
idential Mid-Range $8,049,780 | $13,130,100
idential High-End $21,463,200 | $25,872,000
ce/Incubator $1,907,100 $4,070,700
$1,237,000 | $1,961,200
D/Office $317,850 $678,450
aterfront Commercial $1,546,250 $2,451,500

$40,131,680 | $64,249,500

The construction of new facilities in the MDP area
will also generate additional employment in the form
of short-term construction jobs. Implementation of
this alternative is expected to result in between $40.1
and $64.2 million in new construction within the
study area. Assuming that 45% of this cost is for
wages. between $18.1 million and $28.9 million in
construction wages will be paid out. Using the aver-
age construction wage of $38,388 for the region, 470
to 753. person-years of construction employment will
be created.

Tax Revenue Created/Lost

The implementation of this alternative is expected to
generate between $40.1 and $64.2 million in new con-
struction activity. The projected construction costs are
detailed in the Table 4.3-10.

Source: Marshall Valuation Service and RKG Associates,

Inc.

Assuming that these facilities are assessed at an av-
erage of 70% of their construction cost, the New Lon-
don tax base would expand by between $28.1 million
and $45.0 million. However, the demolition of existing
structures in this area must also be accounted for.
Approximately $6 million in existing tax base will be
eliminated to implement this plan, making the net in-
‘crease in the tax base between $22.1 million and
$39.0 million. This translates into a net increase in
property tax revenues of between $600,000 and $1.1
million.

4.3.5 Alternative No. 4 - Business Campus

Alternative 4 focuses on development of the study
area as a business campus. The development program
for this alternative is summarized in the Table 4.3-11.

519 520

TABLE 4.3-11 Development Program -

As an offset to the jobs created under this alternative,
Alternative 4 - Business Campus

it is necessary to subtract the existing jobs in the

Land Use Proposed Development study area. It is estimated that 148 to 222 people cur-
tate Park 16 Acres rently work within the study area. Eliminating these
olumbia Cove Area 80-100 Slips jobs brings the net gain from this alternative to be-
ater-Related Commercial 25,000-30,000 SF tween 1,184 and 2,067 jobs. Additional indirect jobs
otel/Conference Center 200 Rooms will also be created in the regional economy, based on

-- sidential Mid-Range 30 Units the recirculation of wages and purchases through the
ce (Existing) 50,500 SF economy. It is estimated that between 949 and 1,610
ce/Incubator 380,000-405,000 SF indirect jobs will be created, as detailed in Table 4.3-

tail 15,000 SF | 13.
D/Office 5,000 SF
aterfront Commercial 20,000-25,000 SF a pages «nh ts sicidtiaiialinn,
Job Creation Alternative 4 - Business Campus

Based on the identified development program, the job Indirect Employment

creation associated with this alternative has been esti- | = Use Category Low Estimate! High Estimate
mated. Direct job creation is projected to be between 1,332 tate Park 2
and 2,289. Office positions account for a large percentage
of total job creation, with 1,150 to 1,700 jobs. Table 4.3-12

provides the estimated job creation by land use category.

TABLE 4.3-12
Estimated Range of Direct Employment -
Alternative 4 - Business Campus

= Direct Employment

d Use Category Low Estimate Estimate
tate Park 4 6
olumbia Cove Area 1 5
ater-Related Commercial 46 120
otel/Conference Center 68 100
ce (Existing) 126 253
ce/Incubator 1,013 1,620
tail 23 60
D/Office 13 25
aterfront Commercial 38 100
1,332 2,289

Source: Urban Land Institute and RKG Associates, Inc.

3

olumbia Cove Area 1 3
ater-Related Commercial 23 60
otel/Conference Center 37 54
ce (Existing) 94 188
ce/Iucubator 753 1,204

i 12 30
D/Office 9 19
aterfront Commercial 19 50
tal 949 1,610

Source: U.S. Department of Commerce and RKG Associ-
ates, Inc.

The construction of new facilities in the study area will
also generate additional employment, in the form of -
short-term construction jobs. Implementation of this
alternative is expected to result in between $56.8 and
$104.2 million in new construction within the MDP
area. Assuming that 45% of this cost is for wages, be-

tween $25.5 million and $46.9 million in construction
wages will be paid out. Using the average construction

521

wage of $38,388 for the region, 665 to 1,222 person-
years of construction employment will be created.

Tax Revenue Created/Lost

The implementation of this alternative is expected to
generate between $60.9 and $104.2-million in new
construction activity. The projected construction costs
are detailed in the Table 4.3-14.

TABLE 4.3-14
Estimated Construction Costs -
Alternative 4 - Business Campus

Land Use Category _ Low Estimate! High Estimate

Construction Costs

522

in property tax revenues of between $930,000 and
$1.8 million at full build-out.

4.3.6 Alternative No. 5 - Mixed Use 1

Alternative 5 focuses on mixed use development of
the study area. The development program is summa-
rized in the Table 4.3-15.

tate Park $3,200,000 $12,000,000
olumbia Cove Area $450,000 $750,000
ater-Related Commercial! $1,855,500 $2,941,800
otel/Conference Center | $20,920,000 $26,038,000

idential Mid-Range $1,788,840 $2,917,800

ce/Incubator $25,745,850 $54,954,450
tail $927,750 $1,470,900
D/Office $317,850 $678,450
aterfront Commercial $1,546,250 $2,451,500
tal $56,752,040 | $104,202,900

TABLE 4.3-15
Development Program -
Alternative 5 - Mixed Use 1
Proposed Development
16 Acres
olumbia Cove Area 80-100 Slips
ater-Related Commercial 25,000-30,000 SF
otel/Conference Center 200 Rooms
idential Mid-Range 115 Units
25,000 SF
ce (Existing) 50,500 SF
ce/Incubator 100,000 SF
10,000 SF
5,000 SF
aterfront Commercial 20,000-25,000 SF

Source: Marshall Valuation Service and RKG Associates,

Inc.

Assuming that these facilities are assessed at an
avenge of 70% of their construction cost, the New
London tax base would expand by between $39.7 mil-
lion and $72.9 million. However, the demolition of ex-
isting structures in this area must also be accounted
for. Approximately $5.6 million in existing tax base
will be eliminated to implement this plan, making the
net increase in the tax base between $34.10 million
and $67.3 million. This translates into a net increase

Job Creation

Based on the identified development program, the job
creation associated with this alternative has been es-
timated. Direct job creation is projected to be between
574 and 1,099. Due to the density of employment, of-
fice uses contribute the largest number of jobs, ac-
counting for 389 jobs under the low estimate and 678
under the high estimate. Table 4.3-16 provides the es-
timated job creation by land use category.

523

TABLE 4.3-16
Estimated Range of Direct Employment -
Alternative 5 - Mixed Use 1

524

TABLE 4.3-17
Estimated Range of Indirect Employment -
Alternative 5 - Mixed Use 1

= Direct Employment
: d Use Category Low Estimate High
tate Park 4 6
olumbia Cove Area 1 5
ater-Related Commercial 46 120
otel/Conference Center 68 100
thletic Club 13 50
ce (Existing) 126 253
ce/Incubator 250 400
tail 15 40
D/Office 13 25
aterfront Commercial 38 100
tal 574 1,099

Source: Urban Land Institute and RKG Associates, Inc.

hie Indirect Employment
d Use Category Low Estimate Estimate}
tate Park 2 3
olumbia Cove Area 1 3
ater-Related Commercial 23 60
otel/Conference Center 37 54
thletic Club 7 27
ce (Existing) 94 188
ce/Incubator 186 297
tail 8 20
D/Office 9 19
aterfront Commercial 19 50
tal 385 720

Source: U.S. Department of Commerce and RKG Associ-

ates, Inc.

As an offset to the jobs created under this alternative,
it is necessary to subtract the existing jobs in the
study area. It is estimated that 148 to 222 people cur-
rently work within the study area. Eliminating these
jobs brings the net gain from this alternative to be-
tween 426 and 877 jobs.

Additional indirect jobs will also be created in the re-
gional economy, based on the recirculation of wages
and purchases through the economy. It is estimated
that between 385 and 720 indirect jobs will be cre-
ated, as detailed in Table 4.3-17.

The construction of new facilities in the study area
will also generate additional employment in the form
of short-term construction jobs. Implementation of
this alternative is expected to result in between $43.7
and $72.9 million in new cc.struction within the
study area. Assuming that 45% of this cost is for
wages, between $19.7 million and $32.8 million in
construction wages will be paid out. Using the aver-
age construction wage of $38,388 for the region, 512
to 854 person-years of construction employment will
be created.

Tax Revenue Created/Lost

The implementation of this alternative is expected to
generate between $47.8 and $72.9 million in new con-
struction activity. The projected construction costs are
detailed in Table 4.3-18.

525

TABLE 4.3-18
Estimated Construction Costs -
Alternative 5 - Mixed Use 1
Construction Costs
Low Estimate High

$3,200,000 ($12,000,000

$450,000 $750,000

$1,855,500 $2,941,800

$20,920,000 26,038,000

$6,857,220 ($11,184,900

$1,591,000 $2,299,000

$6,357,000 13,569,000

$618,500 $980,600

$317,850 $678,450

$1,546,250 $2,451,500

$43,713,320 72,893,250

Source: Marshall Valuation Service and RKG Associates,

Inc.

Assuming that these facilities are assessed at an av-
erage of 70% of their construction cost, the New Lon-
don tax base would expand by between $30.6 million
and $51.0 million. However, the demolition of existing
structures in this area must also be accounted for.
Approximately $6 million in existing tax base will be
demolished to implement this plan, making the net
increase in the tax base between $24.6 million and
$45.0 million. This translates into a net increase in
property tax revenues of between $670,000 and $1.2
million.

4.3.7 Alternative No. 6 - Mixed Use 2

Alternative 6 focuses on mixed use development of
the study area. The development program is summa-
rized in the Table 4.3-19.

526

TABLE 4.3-19
Development Program -
Alternative 6 - Mixed Use 2
Proposed Development
16 Acres
olumbia Cove Area 80-100 Slips
ater-Related Commercial 25,000-30,000 SF
otel/Conference Center 250 Rooms
idential Mid-Range 115 Units
25,000 SF
ce (Existing) 50,500 SF
ce/Incubator 100,000 SF
i 10,000 SF
5,000 SF
aterfront Commercial 20,000-25,000 SF

Job Creation

Based on the identified development program, the job
creation associated with this alternative has been
estimated. Direct job creation is projected to be be-
tween 591 and 1,124. Due to the density of employ-
ment, office uses contribute the largest number of
jobs, accounting for 389 jobs under the low estimate
and 678 under the high estimate. Table 4.3-20 pro-
vides the estimated job creation by land use category.

527

TABLE 4.3-20
Estimated Range of Direct Employment -
Alternative 6 - Mixed Use 2

|

tate Park
umbia Cove Area
Water Related Commercial
Hotel/Conference Center
Athletic Club

~—

Ses88e88..

Direct
Land Use Category Low Estimate

4
1
46
85
13
126
250
15
13
38

construction wages will be paid out. Using the aver-
age construction wage of $38,388 for the region, 574
to 931 person-years of construction employment will
be created.

Total 591 1,124
Source: Urban Land Institute and RKG Associates, Inc.

As an offset to the jobs created under this alternative.
it is necessary to subtract the existing jobs in the
study area. It is estimated that 148 to 222 people cur-
rently work within the study area. Eliminating these
jobs brings the net gain from this alternative to be-
tween 443 and 902 jobs.

Additional] indirect jobs will also be created in the re-
gional economy, based on the recirculation of wages
and purchases through the economy. It is estimated
that between 394 and 734 indirect jobs will be cre-
ated, as detailed in Table 4.3-21.

TABLE 4.3-21
Estimated Range of Indirect -
Alternative 6 - Mixed Use 2

| Indirect :
Low Estimate Estimate

2 3

1 3

23 60

46 67

7 27
94 188

186 297

8 20

9 19

19 50

394 734

Source: U.S. Department of Commerce and RKG Associ-
ates, Inc.

Tax Revenue Created/Lost

The implementation of this alternative is expected to
generate between $48.9 and $79.4 million in new con-
detailed in Table 4.3-22.

529

TABLE 4.3-22
Estimated Construction Costs -
Alternative 6 - Mixed Use 2
Construction Costs
Land Use Category Low Estimate

tate Park $3,200,000 | $12,000,000
umbia Cove Area $450,000 $750,000
ater-Related Commercial | $1,855,500 $2,941,800
otel/Conference Center | $26,150,000 | $32,547,500
idential Mid-Range $6,857,220 | $11,184,900
thletic Club $1,591,000 $2,299,000
Office/Incubator $6,357,000 | $13,569,000
$618,500 $980,600
D/Office $317,850 $678,450
aterfront Commercial $1,546,250 $2,451,500
Total $48,943,320 | $79,402,750

Source: Marshall Valuation Service and RKG Associates,

Inc.

Assuming that these facilities are assessed at an av-
erage of 70% of their construction cost, the New Lon-
don tax base would expand by between $34.2 million
and $55.6 million. However, the demolition of existing
structures in this area must also be accounted for.
Approximately $6 million in existing tax base will be
demolished to implement this plan, making the net
increase in the tax base between $28.2 million and
$49.6 million. This translates into a net increase in
property tax revenues of between $770,000 and $1.4
million.

4.3.8 Summary

The six land use alternatives for the study area have
impacts that are widely varied. Table 4.3-23 provides
an indication of the range of direct employment asso-
ciated with each of the six land use alternatives

530

proposed for the study area. Implementation of any of
the six alternatives (including the no action alterna-
tive) would result in a net increase in jobs and prop-
erty tax revenues.

Alternative 4 (Business Campus) is the highest gen-
erator of jobs, followed by Alternatives 1, 6, 5, 2, and
3. It is interesting to note that Alternative 1 (No Ac-
tion) generates the second highest number of jobs
(1,779), behind only the Business Campus Alternative
(#4). This is because the No Action Alternative antici-
pates the reuse of approximately 380,000 square feet
of existing facilities at the Naval Undersea Warfare
Center (NUWC). The reuse of this space accounts for
more than 1,500 of the 1,779 jobs to be created under
this alternative.

In addition to these direct jobs, the six alternatives
are also expected to result in the creation of addi-
are expected to be created as direct employees on the
site spend their wages in the regional economy for
food, clothing, etc. Table 4.3-24 provides an estimate
of the projected number of indirect jobs expected to be
created in the study area for each of the six land use
alternatives.

The land use alternatives for the study area also have
varied projected construction impacts. Total construc-
tion costs range from as low as $3.2 million to as high
as $113.0 million. Estimates of construction wages
range from as low as $1.4 million to as high as $51
million. Between 37 and 1,304 person-years of con-
struction are expected to be created through these
projects, as shown in Table 4.3-25.

New tax revenues are projected to range from a mod-
est $57,000 to as much as $2.0 million as presented in
Table 4.3-26.

TABLE 4.3-23
Range of Employment Estimates by Land Use Alternative

(Direct Employment - Low Estimate)

Land Alt. 1 Alt. 2 Alt. 3 Alt. 4 Alt. 5 Alt 6
Use No Recreation/ | Residential/| Business | Mixed | Mixed
Category Action Tourism |Commercial| Campus Use 1 Use 2
State Park 4 8 4 4 4 4
Columbia Cove Area - 1 1 1 1 1
Water-Related Commercial 46 46 46 46 46
Hotel - 27 - - 0 -
Recreation Center - 13 - - 0 -
Outdoor Recreation Area - - 1 - 0 -
Museum(s) - 4 - - 0 -
Hotel/Conference Center - - - 68 68 85
Residential High-End - - - - - -
Athletic Club - - - - 13 13
Office (Existing) 126 126 126 126 126 126
Office/Incubator 950 200 75 1,013 250 250
Retail - 31 31 23 15 15
R&D/Office - 13 13 13 13 13
Waterfront Commercial - 38 38 38 38 38
Total 1,080 506 335 1,332 574 591
(Direct Employment - High Estimate)
Land Alt. 1 Alt. 2 Alt. 3 Alt. 4 Alt. 5 Alt 6
Use No Recreation/ | Residential/| Business | Mixed | Mixed
Category Action Tourism |Commercial| Campus Use 1 Use 2
State Park 6 12 6 6 6 6
Columbia Cove Area - 5 5 5 5 5
Water-Related Commercial - 120 120 120 120 120
Hotel : | : ; . ;
Recreation Center - 50 - - - -
Outdoor Recreation Area - - 1 - - -
Museum(s) - 14 - - - -
Hotel/Conference Center - - - 100 100 125
Residential Mid-Range - - - - - -
Residential High-End - - - - - -
Athletic Club - - - - 50 50
Office (Existing) 253 253 .. 253 253 253 253
Office/Incubator 1,520 320 120 1,620 400 400
Retail - 80 80 60 40 40
R&D/Office - 25 25 25 25 25
Waterfront Commercial - 100 100 100 100 100
Total 1,779 1,019 710 2,289 1,099 1,124

Tes

TABLE 4.3-24
Range of Indirect Job Creation by Land Use Alternative

Alternative 1} Alternative | Alternative 3 | Alternative 4 | Alternative 5 | Alternative 6
No Action | Recreation/ | Residential/ Business Mixed Mixed

Tourism 2 Commercial Campus Use 1 Use 2
Low Estimate 802 337 220 949 385 394
High Estimate 1,321 659 452 1,610 720 734

Source: U.S. Department of Commerce and RKG Associates, Inc.
TABLE 4.3-25
Summary of Construction Impacts by Land Use Alternative
Alt. 1 Alt. 2 Alt. 3 Alt. 4 Alt. 5 Alt. 6
No Recreation/ | Residential | Business Mixed Mixed
Action Tourism 2 |Commercial| Campus—} Usel Use 2
Construction Costs — Low $3,200,000} 28,321,500) 40,131,680! 56,752,040 | 43,713,320) 48,943,320
Construction Costs — High $12,000,000} 58,098,330! 64,249,500} 104,202,900 | 72,893,250; 79,402,750
Construction Wages — Low $1,440,000} 12,704,175! 18,059,256! 25,538,428 | 19,670,994| 22,024,494
Construction Wages — High $5,400,000} 26,144,249) 28,912,275| 46,891,305 | 32,801,963} 35,731,238
Construction
Employment — Low 38 331 470 665 512 574
Construction
Employment — High 141 681 753 1,222 854 931
Source: Marshal! Valuation Service and RKG Associates, Inc.
TABLE 4.3-26
Summary of Tax Revenues Generated by Land Use Alternative
Alt. 1 Alt. 2 Alt. 3 Alt. 4 Alt. 5 Alt. 6
No Recreation/ Residential | Business Mixed Mixed
Action Tourism 2 |Commercial| Campus Use 1 Use 2

Tax Revenues — Low $61,152 375,704 603,116 931,651 671,562 771,507
Tax Revenues — High $229,320 946,459 1,064,008 1,838,437 | 1,229,190 | 1,353,587

Source: Marshall Valuation Service and RKG Associates, Inc.

ZES

533

4.4 Neighborhood/Housing Impacts

The overall character of the Fort Trumbull area will
be enhanced by the disposition of a portion of the
NUWC property (+16 acres) to the Department of En-
vironmental Protection for the creation of a state-
owned and operated park. This park will have a posi-
tive impact on the neighborhood, both physically and
economically. An aesthetically pleasing park would
beautify the area, significantly increase useable open
space, provide public access to the waterfront, and, as
a consequence of this $20 million public investment,
increase surrounding land values to the benefit of the
residents. These benefits will accrue to each of the al-
ternatives to be discussed herein.

4.4.1 Alternative No. 1 - No Action

The development of the NUWC property alone would
not directly impact the area’s housing stock since the
No Action plan calls for only the creation of areas for
open space, maritime conveyance, and public sale.
There would be no project generated changes in the
residential or commercial properties in the Fort
Trumbull MDP area. However, private investment in
the existing building stock would likely be stimulated
by development of the State Park and, depending on
the future use of the NUWC area to be sold, further
investment in residential and commercial properties
is possible.

4.4.2 Alternative No. 2 - Recreation/Tourism

Both the Fort and Gateway Areas would be signifi-
cantly impacted by a reuse option geared toward rec-
reation and tourism. The state park at Fort Trumbull
will serve to improve the appearance and waterfront
accessibility of the area. The NUWC site has served

534

various military purposes since the American Revolu-
tion and has not been generally open to the public.
Amenities such as a recreation center, museum, and
the riverwalk would provide activities for New Lon-
don residents to enjoy as well as tourist coming to this
new destination. New opportunities for employment
would be created through neighborhood and water-
related retail activities, development of a hotel, and
R&D, incubator, and office spaces. Neighborhood re-
tail is proposed to service employees and visitors to
the area, as well as adjoining residential areas.

In this alternative, the Gateway Area would become
an extension of the adjoining Shaw’s Cove Redevel-
opment Area that was redeveloped during the 1980's.
The addition of office, incubator, and retail uses along
Howard Street would complete a transition in use and
function of this corridor, which began approximately
20 years ago. All alternatives that propose redevel-
opment of the Howard Streét corridor would serve to
implement City policy to renew this area.

The current neighborhood and its housing stock
would cease to exist in its present configuration under
this scenario. All of the 115 dwelling units in the area
would be removed, of which 92 are currently occupied.
(Fort Area: 81 dwelling units, 69 households. Gateway
Area: 34 dwelling units, 23 households.) This would
require the relocation of all the families in the area.
In addition, 28 businesses may be displaced. All
households and businesses displaced would receive
assistance under the Connecticut Uniform Relocation
Assistance Act and the Relocation Plan adopted as
part of the MDP. Table 4.4-1 presents an estimate of
displacement under this scenario.

535

4.4.3 Alternative No. 3 - Residential/Commercial

This alternative proposal seeks to create a balance
between the current character of the neighborhood
with new opportunities for the future. The area would
maintain a significant amount of land in residential
uses (+25.8 acres) while adding the state park (+16
acres) along with new retail and commercial uses.
The retail uses would be geared toward employees,
the tourist coming to the area, as well as the
neighborhood residents. The office component along
Howard Street would serve to link the area with the
existing commercial and industrial uses found in the
Gateway Area. In addition to the public amenities
such as the state park and riverwalk, an area of open
space (+3.5 acres) would be preserved in the center of
the Fort Area.

The housing stock would be beneficially changed by
this land use alternative. Forty-five dwelling units in
the Fort Trumbull area would be removed, of which
40 are occupied. The plan does allow 36 existing
dwelling units, of which 29 are currently occupied, to
remain. Also, 29 households in 34 dwelling units
would be displaced from the Gateway Area.
In total, 79 of the 115 dwelling units would be dis-
placed under this scenario. This would result in the
relocation of 63 households. In addition, 28 business
may be displaced. All households and businesses dis-
would receive assistance under the Connecti-
cut Uniform Relocation Assistance Act and the
Relocation Plan adopted as part of this MDP. Table
4.4-2 presents an estimate of displacement under this
scenario.

# of
— Total#of | Dwelling Households | Businesses
Land Area | Dwelling | Units to be Total # of to be
Land Use Type Property Use Uni Demolished | Households | Displaced Displaced
State Park, Navy & -
Coast Guard Facilities Fort Trumbull 36 36 29 29 1
Columbia Cove Marina Fishing Docks 0 0 0 0 0
Hotel 0 0 0 0 0
Recreation Center 0 0 0 c 1
Museum Res/Comm 39 39 35 35 8
Office (Existing) 0 0 0 0 3
Office/Incubator Res/Comm 17 17 8 8 7
R&D/Office Vacant/Industrial 1 1 0 0 3
Retail Res/Comm 17 17 15 15 2
Water Related Commercial | Res/Comm 5 5 5 5 2
Waterfront Commercial RR/Comm 0 0 0 0 1
WWTP 0 0 0 0 0
115 115 92 92 28

537

TABLE 4.4-2
Estimate of Displacement -
Alternative 3 - Residential/Commercial

# of

Total#of | Dwelling

Land Area | Dwelling | Units to be

(Ac.) Units Demolished
16.0 0 0
0.0 0 0
3.5 12 12
16.5 63 27
6.4 0 0
2.2 4 4
2.1 0 0
1.3 1 1
3.0 17 17
2.5 5 5
4.3 0 0
10.5 0 0
2.9 13 13
71.2 115 79

Total # of

|

BacoaRowoofgco

(

a
5

fs

Bwckwnwawoukro

538

With this alternative, there would be new residential
uses created in the Gateway Area. Twenty dwelling
units would be built, resulting in a net loss of 14
dwelling units. Furthermore, there would be 115 mid-
density dwelling units in the area (36 preserved plus
79 newly constructed) and 160 high-density dwelling
units at the completion of the project. This would re-
sult in 275 units in the area compared to the 81 that
currently exist.

4.4.4 Alternative No. 4 - Business Campus

This alternative commits most of the developable area
to office, incubator, and campus use. A hotel/
conference center on 7.5 acres supports the office
function. The Gateway Area along Howard Street
would accommodate office/incubator use on the east-
ern side, much of which is an existing building, and
residential and neighborhood retail use on the west-
ern side. This alternative brings residential use to
Howard Street, which currently is predominately non-
The current neighborhood and all of its housing stock
except eight dwelling units would cease to exist in its
current configuration under this scenario. Of the 115
dwelling units in the area, 107 would be removed, of
which 86 are currer.tly occupied. (Fort Area: 81 dwell-
ing units removed, 69 households. Gateway Area: 26
dwelling units removed, 16 households.) This would
require the relocation of 85 households from the area.
There would be 22 new dwelling units created under
this alternative for a net loss of 85 dwelling units. In

539

part of this MDP. Table 4.4-3 presents an estimate of
displacement under this scenario.

4.4.5 Alternative No. 5 - Mixed Use 1

The addition of a hotel/conference center, an athletic
club/field, the Fort Trumbull State Park, and water-
related commercial activities in this alternative seeks
to expand and improve the current residential/
commercial character of the neighborhood, creating a
truly mixed land use environment. This is accom-
plished by expanding the office/incubator uses in the
Gateway Area, changing the location of some of the
residential uses, while keeping their number con-
stant, and providing residents with opportunities for
recreation. As with the other alternatives, the crea-
tion of the state park and riverwalk would serve to
balance the built environment with open space and
natural settings.

540

Land Use Type

State Park, Navy &
Coast Guard Facilities
Columbia Cove Marina
Hotel/Conference Center
Residential

Office (Existing)
Office/Incubator
R&D/Office

Retail

Water Related Commercial
Waterfront Commercial
WWTP

Residential (Existing)

Current
Property Use

Fort Trumbull
Fishing Docks
Fort Trumbull//RR
Res/Comm
Res/Comm
Res/Comm
Vacant/Industrial
Res/Comm
Res/Comm
RR/Comm
WWTP
Residential

TABLE 4.4-3
Estimate of Displacement -
Alternative 4 - Business Campus
# of
Total # of Dwelling
Land Area | Dwelling | Units to be
(Ac.) Units Demolished
16.0 0 0
0.0 0 0
7.5 0 0
3.1 14 14
2.2 0 0
22.1 79 79
1.3 1 1
1.8 8 8
2.5 5 5
2.1 0 0
10.5 0 0
0.8 8 0
69.9 115 107

Total # of
Households

SaraccanwncoBohtococne

# of
Households
to be
Displaced

RocoounoBortoco

# of
Businesses
to be
Displaced

BrornrwRwworo

541

The housing stock in the area would undergo no net
change in number of dwelling units in this reuse op-
tion. The plan calls for 115 dwelling units, which is
the same as the current number. Of these 115 dwell-
ing units, 36 would be in existing structures, while
the remaining 79 would be from new construction.
This would mean the relocation of 63 households.
(Fort Area: 45 dwelling units removed, 40 households.
Gateway Area: 34 dwelling units removed, 23 house-
holds.) Additionally, there are 28 businesses in the
area that may require relocation. All households and
businesses displaced would receive assistance under
the Connecticut Uniform Relocation Assistance Act
and the Relocation Plan adopted as part of this MDP.
Table 4.4-4 presents an estimate of displacement un-
der this scenario.

4.4.6 Alternative No. 6 - Mixed Use 2

The current neighborhood and its housing stock
would cease to exist in its present configuration under
this scenario. All of the 115 dwelling units in the area
would be removed, of which 92 are currently occupied.
(Fort Area: 81 dwelling units, 69 households. Gateway
Area: 34 dwelling units, 23 households.) This would
require the relocation of all the families in the area.
In addition, 28 businesses may be displaced. All
households and businesses displaced would receive
assistance under the Connecticut Uniform Relocation
Assistance Act and the Relocation Plan adopted as
part of this MDP. The level of displacement under this
alternative would the same as Alternative 2 as pre-
sented in Table 4.4-1.

542

TABLE 4.4-4

Estimate of Displacement -
Alternative 5 - Mixed Use 1

Land Use Type
State Park, Navy &
Coast Guard Facilities
Columbia Cove Marina
Hotel/Conference Center
Athletic Club/Field
Residential Mid-Range
Office (Existing)
Office/Incubator
R&D/Office
Water Related Commercial
Waterfront Commercial
WWTP

Current
Property Use

Fort Trumbull
Fishing Dock
Fort Trumbull/RR
Res/Comm
Res/Comm
Res/Comm
Res/Comm
Vacant/Industrial
RR/Comm
WWTP
Residential

Land Area
(Ac.)

16.0
0.0
7.5
3.5
16.5
2.2
8.0
1.3
2.5
2.1
10.5
70.1

# of
Total # of Dwelling
Dwelling Units to be
Units Demolished

0 0
0 0
0 0
12 12
63 27
0 0
34 34
1 1
5 5
0 0
0 0
115 79

# of # of
Households to Businesses to
Total # of be be

Households Displaced Displaced

SooncokoSpoce
to oe
BooncohoBpoco

BornwowaerH oo

543

4.5 Community Facilities and Services Impacts
4.5.1 Common Elements

Fire Protection — Al) of the land use alternatives are
expected to have similar positive impacts on local fire
and police services. The demolition of old, fire prone
buildings is expected to reduce the potential for oc-
currence of an uncontrolled fire and enhance fire pro-
tection capabilities in the area. Construction of new
buildings would be completed in accordance with cur-
rent fire code and would employ sprinkler systems to
provide additional fire protection capabilities. The
improvement of public water service in the area will
also allow for the installation of additional fire hy-
drants. Additionally, redevelopment activities can be
designed to provide emergency vehicle access to the
buildings, thus improving accessibility over existing
conditions. Proposed roadway improvements would
provide better emergency access to the area in the
event of a fire. (Personal communication, 10/6/98,
Chief Samuels). As part of the NUWC closure, the
City of New London acquired a Navy fire truck, thus
increasing its equipment inventory.

Police Protection — Current land uses in the MDP
area limits the volume of people, minimizing the need
for police patrol. This is particularly evident at the
NUWC property which is currently secured by Navy
staff. All of the alternatives would result in increased
use of the Fort Trumbull area, including NUWC, thus
requiring more frequent police patrol of the area.
Proposed alternatives which minimize open public ac-
cess are viewed as most favorable for police protec-
tion. (Personal communication, 10/6/98, Deputy Chief
Gavitt).

Health Care — Health care facilities are not antici-
pated to be measurably affected by the implementa-
tion of any of the alternatives.

544

Recreation — The disposition of a portion of the
NUWC property (+16 acres) to the Department of En-
vironmental Protection would result in a positive im-
pact to parks and recreation. The state-owned and
operated park would complement the local park net-
work and provide additional] waterfront access to the
New London residents and to visitors from outside
the New London area This new amenity would be af-
forded without any additional maintenance or staffing
burden on the city, as these responsibilities would rest
on the Department of Environmental! Protection.

4.5.2 Alternative No. 1 —- No Action

Since development at the NUWC property associated
with this alternative does not include a residential
component, no impact on education or the need for
additional educational facilities is anticipated. A posi-
tive impact on education is anticipated as a result of
the Fort Trumbull State Park due to the educational
aspect of the historic fort and associated park.

Emergency services (i.e., police, fire, ambulance, etc.)
are not expected to be negatively impacted by this al-
ternative. A far less intense land use would result in
comparison to the fully operational NUWC facility at
this site.

As indicated, the positive impacts of locating a state
park in this area would be experienced under this al-
ternative.

4.5.3 Alternative No. 2 - Recreation/Tourism

A component of the Recreation/Tourism alternative
includes cultural and museum recreation, with the
potential for a 50,000 to 70,000 square foot museum
facility. This. in binati th tl aeaattunall

545

aspect of the proposed Fort Trumbull State Park,
would have a positive impact on education in the
community. No need for additional educational facili-
ties or impact on New London's school system is an-
ticipated in association with this alternative.

A positive benefit from the proposed Fort Trumbull
State Park would be similar to that described in Al-

ternative 1, except that the park would be expanded
from 16 acres to approximately 30 acres. The con-

additional number of dwelling units under this alter-
native would be on the order of 169.

Table 4.5-1 illustrates the demographics of New Lon-
don’s school aged population under exsting and pro-

from
Existing to
Proposed
Conditions
+450
umber of 10,712 126 295 +169
~~"
—s 2.66 2.66 2.66 0
ity?
tion 6.5% 22 51 +29
% or number)
5 through
0 Years’
tion 2.9% 10 23 +13
% or number)
ll
3 Years’
tion 3.5% 12 27 +15
% or number)
14
7 Years

yy) eee
sumed to be age 10 and one-half assumed to be age 11.
Note: Information current as of August 1998

It is assumed that elementary school aged children
are ages five through 10 years; middle school aged

547

children are ages 11 through 13; and high school aged
students are ages 14 through 17. As a result of the
proposed conditions, there is the potential for an addi-
tional 57 children in the New London public school
system (29 in elementary school, 13 in middle school,
and 15 in high school). These estimates are somewhat
conservative in that a fraction of school aged students
attend non-public schools or require additional assis-
tance through a special education program offered at
the Little Red Schoolhouse. Additionally, it is possible
that some of the residential population would be relo-
cating from within the city and would, therefore, sim-
ply be a redistribution of school aged children.

At the present time, most of the New London schools
operate at enrollment levels below the rated capacity
of the buildings. The majority of the MDP area lies
within the Harbor School elementary education dis-
trict. This facility currently (1998/99 school year) has
an excess capacity of about 100 students. The Bennie
Dover Jackson middle school has additional capacity
for approximately 50 students, and New London High
School has capacity for an additional 75 students.

Based on the current enrollment and maximum ca-

548

4.5.5 Alternative No. 4 - Business Campus

This alternative allocates approximately 4.1 acres of
residential use west of the railroad in the Gateway
Area. This would result in approximate!y 30 dwelling
units in the area. Existing residential use in the proj-
ect area occupies approximately 45.2 acres, with a
resultant 126 dwelling units (as of August 1998).
Therefore, there would be an overall decrease in resi-
dential use, with an associated decrease in school
aged children in the MDP area. Therefore, no nega-
tive impacts are anticipated with respect to educa-
tional facility needs under this alternative.

The positive benefits from the proposed Fort Trum-
bull State Park and riverwalk would be the same as
described in previous alternatives. Additional recrea-
tional amenities are also offered in this alternative,
including a possible marina use and a 200-room hotel/
conference center with views of the waterfront. These
features are expected to result in a positive impact to
parks and recreation since they would replace non-
recreational land uses.

4.5.6 Alternative No. 5 - Mixed Use 1

This alternative allocates approximately 16.5 acres of
residential use east of the railroad in the Fort Area
and NUWC property with a resultant 115 dwelling
units. Existing residential use in the project area oc-
cupies approximately 45.2 acres, with a resultant 126
dwelling units (August 1998). Therefore, there would
be an overall decrease in residential use, with an as-
sociated decrease in school aged children in the MDP
area. Therefore, no negative impacts are anticipated
with respect to educational facility needs under this
alternative.

at

549

The positive benefits from the proposed Fort Trum-
bull State Park and riverwalk would be the same as
described in previous alternatives. Additional recrea-
tional amenities are also offered in this alternative,
including a 25,000 athletic club/field, possible marina
use, and a 200-room hotel/conference center with
views of the waterfront. These features are expected
to result in a positive impact to parks and recreation
since they would replace non-recreational land uses.

4.5.7 Alternative No. & - Mixed Use 2

The impacts of Alternative 6 are identical to that of
Alternative 5, except that additional open/recreational
space and opportunities are provided in Alternative 6.

Aesthetic/Visual Resource Impacts

The proposed municipal development of the Fort
Trumbull area will alter the appearance of the
neighborhood when viewed from both interior and ex-
terior locations. The primary viewsheds that look out
Shaw's Cove, observers viewing the site from or
across the Thames River (including small craft and
ferry boats), the view from Pequot Avenue and the ad-
jacent Pfizer site, and limited views from the Gate-
way Area. The railroad embankment limits external
views of the Fort Area from the west.

The aesthetic quality of a landscape is somewhat sub-
jective, depending upon the judgment and experiences
of the viewer. Typical elements include mass, texture,
color, height and width proportions, and the presence
of natural versus common or unusual cultural fea-
tures.

550

4.6.1 Alternative No. 1 - No Action

The visual appearance of the site would have moder-
ate change, even if no action were to be taken under
the MDP process. The private sale of NUWC build-
ings could lead to alteration of that site, and the state
park would still proceed to clear older wood frame
structures from the southern half of the NUWC prop-
erty. This would improve the view from the Fort Area.

There would be no significant changes anticipated in
the Gateway and Fort Areas.

4.6.2 Alternative No. 2 - Recreation/Tourism —

The redevelopment of the Gateway and Lower Pequot
Avenue Area would noticeably alter the appearance of
these areas, with removal of existing buildings and
construction of new ones. The exact composition of
size, shape, and color has not been established at this

time.

The Fort Area west of Smith Street would have a to-
tally new look, intended to complement a new cul-
tural center/museum and recreational center theme.
This would likely involve new low-rise buildings with
pedestrian walks, terraces, and parking lots. Many
would consider this an improvement over existing
conditions.

The proposed Columbia Cove area and adjacent hotel
site would be designed to complement the waterfront
and be visible across the river and Shaw’s Cove. A
well balanced waterfront design with public access
would be attractive.

The focal point of Alternative 2 is an enlarged Fort
Trumbull State Park, including removal of additional
buildings in its northern area east of Smith Street.
This would open up views of this congested site from

551

the river, and introduce natural elements into the
viewshed.

4.6.3 Alternative No. 3 - Residential/Commercial

New residential units would be constructed in the
underutilized area along Howard Street and would
need to complement the scale of the neighborhood.
They would serve as a transition to office uses east of
Howard Street. Generous front setbacks would be de-
sirable between these separate uses. Similar colors
and materials would also be desirable. However, it
would be difficult to blend such diverse uses into a
comfortable neighborhood. Medium and high density
residential units, raised on fill or piers in flood prone
areas, would be constructed in the Fort Area on both
sides of the present Smith Street. They are visible
from the river and Shaw’s Cove and would detract
from the waterfront vista. In contrast, the proposed
Columbia Cove area is more likely to be of visual in-
terest, as would be the state park.

The proposed open space between Goshen Street and
the railroad is of internal interest and could be land-
scaped to form an attractive gateway beyond the Wal-
bach Street bridge and buffer the residential area.

4.6.4 Alternative No. 4 - Business Campus

The proposed Gateway Area mix of residential retail!
and office would be similar to Alternative 3, with mi-
nor spatial orientation changes. The core of this al-
ternate is a large area of office and incubator business
space in a campus type of layout. This offers the op-
portunity for an integrated visual design that could
include courtyards, streetscape features, and mini
parks. While not a distant viewshed attraction, it
could complement the marina. Having a band of

552

green along the water and near the hotel would be a
plus.

4.6.5 Alternative No. 5 - Mixed Use 1

The proposed office and office/incubator areas in the
Gateway Area has enough mass to create its own
neighborhood character and needs only a suitable
buffer or transition on the west side. The internal ap-
pearance and use would be self-defined.

The proposed hotel conference center and Columbia
Cove area, as per previous alternatives, can be attrac-
tive waterfront features. The large residential area on
both sides of Smith Street is a difficult backdrop to
the marina and state park, particularly since flood
management regulations would require higher eleva-
tions of these buildings. This could appear, from the
water, as a cluttered hillside of little boxes.

4.6.6 Alternative No. 6 - Mixed Use 2

This alternate is similar to Alternative 5, but with a
reorientation of space in the Fort Area and in the
northern portion of the NUWC property. A 12-acre
passive recreation open space/athletic center would be
provided along the river and the floodplain, with the
Alternative 5 residential areas shifted west away
from the water. This helps to hide the residential area
into the hollow between Smith Street and the railroad
embankment, and opens up the greenway along the
river. It would complement the waterfront and hotel
sites.

4.7

553

Public Utilities and Services Impacts
4.7.1 Common Elements

Under the various land use alternatives, the MDP
area would be partitioned into several different reuse
parcels to be utilized by different tenants. There are
various infrastructure improvements that are com-
mon to all of the land use alternatives. The common
elements are summarized in the ensuing discussion.
Elements that are specific to each alternative are de-
scribed in subsequent sections.

Many of the utility systems that currently serve
NUWC base, including electric, water, steam and
sewage, are contiguous in nature. There will be a
need to ensure that all parcels/buildings have use of
all utilities during and following any site partitioning
and construction.

Water System

The existing water distribution system east of the
railroad right-of-way is currently in poor condition
and is inadequate to provide the necessary fire flows
for the proposed development uses. Fire flow tests
performed to date have verified this. Computer simu-
lations performed by the Navy have indicated that
the flow capacity in the water mains is well below the
normal capacity of the six-inch and eight-inch pipe
sizes indicated on the record plans. This condition is
probably due to advanced tuberculation of the pipe
walls and inoperable gate valves.

It is anticipated that under Alternatives 2 through 6
the layout of the water distribution system infrastruc-
ture will be modified to accommodate a new street
alignment and to meet needed fire flow demands for
the development.

554

It is anticipated that the state park will be on a sepa-
rate private water system which will be intercon-
nected with the City of New London water system at
several master meters at the perimeter of the park.
The U.S. Coast Guard and the Naval facilities will be
provided water from the New London system via
easements across the state park or in a relocated
street.

Water demands associated with all of the alternatives
are anticipated to be less than historic demands when
NUWC was fully operational. Water usage at the
NUWC facility was estimated in March of 1987 by the
Naval Facilities Engineering Command, Northern
Division in a study entitled “Utilities Systems As-
sessment.” At that time, all meters supplying water to
the NUWC facility were found to be inoperative, as
well as 23 of 26 individual building meters. Water
demand was estimated based on population of the
buildings multiplied by 30.75 gallons per capita per
day usage. The daily flow was estimated at 43,671
gallons.

Existing water demands off the NUWC site but
within the MDP area is estimated at 75,200 gpd. If
the estimated NUWC use of 43,671 gpd is added to
this, a rough estimate of the historic usage is 119,000.

Sanitary Sewer System

There is currently adequate capacity in the existing
sanitary sewer system to collect the existing and pro-
jected sewage flows (see specific program elements). It
is anticipated that all discharges to the sewers will be
domestic waste and that any industrial waste gener-
ated will be minimal in volume or be contained in a
closed loop system and treated internally. Depending
on the final configuration of the development, new

555

sanitary sewers may need to be constructed along any
relocated road or driveway alignments.

Storm Drainage System

Any significant introduction of constituents such as
nutrients, toxics, heavy metals or pathogens, or sig-
nificant alterations of the physical and chemical
characteristics thereby degrading water quality would
be considered an adverse impact to the estuarine wa-
ters of the Thames River. Hence, the use of advanced
stormwater management associated development in
the Fort Trumbull area will be necessary to protect
coastal water quality and marine life.

If sufficient controls are not utilized, development and
construction have the potential to alter stormwater
quantities and quality. These alterations can be due
to changes in vegetation, impervious cover (roads,
parking lots, buildings), reduced infiltration, diver-
sions, and modified channels or storm drains. Poten-
tial impacts include:

¢ higher peak flow rates;

¢ larger runoff volumes;

* inc: eased flow velocities;

¢ soil erosion;

¢ water quality degradation; and
¢ sediment deposition.

The three fundamental storm drainage needs for this
project are to (1) prevent nuisance flood problems in
developed areas; (2) minimize downstream impacts;
and (3) treat stormwater prior to discharge. Specific
concepts are to control pollutants at their sources,
plan for both frequent and rare storm events, avoid
unnecessary impervious cover, and use multiple

556

treatment practices to reduce pollution loadings and
concentrations.

It is anticipated that some existing storm drains may
be cleaned and reused, while new drainage facilities
will be required where new roads are constructed or
older roads are rebuilt. Of special interest is providing
adequate drainage of the low elevation points at rail-
road underpasses that tend to pond runoff during
storm events which are coincident with high tides. All
new storm drain discharge points will avoid existing
or potential wetlands and have appropriate water
quality controls.

Under all land use alternatives, the existing storm
drainage system will need to be modified to accom-
modate any new roadway alignments and to correct
deficiencies in the existing system. All of the storm
drainage systems will incorporate stormwater quality
renovation elements such as inlet chambers (Vortech-
nics, Stormsceptors, or similar equipment) and/or in-
filtration systems.

DEP general stormwater permits for construction ac-
tivities in tidal areas specify post construction man-
agement requirements, including retention (i.e.
infiltration) of the first inch of runoff from the site. If
retention not possible, detention may be required.
The general permit also requires 80% total suspended
solids removal and velocity dissipation. These ele-
ments will be factored into the Municipal Develop-

ment Planning process and project design.

Each of the alternatives will change the amount of
impervious coverage due to the changes in land use.
Table 4.7-1 presents the change in coverage for the six
alternatives. The estimates are given in ranges since
it is not possible to determine the exact amount until
a more detailed design is developed.

TABLE 4.7-
Estimated Changes in Impervious Coverage
Alternative Existing Proposed Change in
Impervious Impervious Impervious
Coverage Coverage _ :
1 — No Action 45% 40%-45% 0%-5% Reduction
2 — Recreation/
Tourism 45% 35%-40% 5%-10%
3 — Residential’
Commercial 45% 40%-45% 0%-5% Reduction
— Business
Campus 45% 50%-60% 5%-15% Increase
5 — Mixed Use 1 45% 45%-55% 0%-10% Increase
6 — Mixed Use 2 45% 45%-55% 0%-10% Increase

Note: Numbers are approximate.

The changes range from a reduction of 5 to 10% under
the Recreation/Tourism alternative to an increase of 5
to 15% under the Business Campus Alternative. The
changes in the alternatives are largely due to the
parking demand of each alternative. Conventional
engineering design will be utilized to design the pipes
for the storm sewer systems in each of the alterna-
tives. The pipe sizes will be proportionally larger un-
der the more intensive land uses.

Gas

Yankee Gas has adequate capacity to service the fu-
ture development. Gas mains currently exist on most
of the municipal streets in the vicinity of the project
area. Some upgrading of the mains in the roadway
may be required depending on the final configuration
of development. Additional distribution facilities will
need to be constructed on the land of the NUWC base,
since a central steam plant previously heated it.

Energy Use and Conservation

There is no known data readily available on historic
energy use in the MDP area and guidelines have not
been prepared for future energy use. In general, it is
anticipated that new buildings will be more energy ef-
ficient than the older existing buildings, and will need
to conform to or exceed current standards.

High electrical-demand uses are not proposed under
any of the identified land use alternatives. However,
it is anticipated that individual users will take advan-

nents, lighting, and HVAC.

Telephone and Cable

The loca] telephone and cable utilities are required to
extend capacity to serve developments if they are lo-
cated on a public street. If it is desired to have facili-
ties located underground in the roadway, the owner/
developer is required to contribute to the cost. Exten-
sion of telephone service to private property would
have to be completed by the owner/developer.

4.7.2 Alternative No. 1 - No Action

Under the No Action alternative, there will be a net
reduction in utility demand from the historical usage
due to a reduction in the intensity of development.

Water Supply
Potable water would continue to be obtained from the
City of New London. Estimated water usage under

this alternative is 108,850 gallons per day (gpd). This is
less than the estimated historic usage in the Fort Trum-
bull area. Flow meters that are currently installed to
monitor water usage are inoperable and would have to be
repaired or replaced in order to monitor the amount of
water consumed by future tenants and uses. The State of
Connecticut and other future occupants will need to up-
grade the water distribution system to accommodate the
needed fire flows. Table 4.7-2 presents estimates of do-
mestic water demand for this alternative.

TABLE 4.7-2
Alternative 1 - No Action

Note: Number of residential units and square footage es
of August 1998.

Sanitary Sewage

Sewage discharge under this alternative would be be-
low the historical rates at the NUWC facility and sur-
rounding area. The existing sewer serving NUWC
and would continue to serve the site and domestic
sewage would continue to be treated at the regional
WPCF. Meters would have to be installed at different
discharge points of each parcel/building in order to
monitor usage for billing purposes.

4.7.3 Alternative No. 2 - Recreation/Tourism

Water Supply

Potable water would continue to be obtained from the
City of New London. Per capita water usage is esti-
mated to be 20 gallons per day per employee and five
gallons per visitor. Estimated water usage is between
41,890 and 43,990 gallons per day. This is less than

installed to monitor water usage are inoperable and
would have to be repaired and/or replaced in order to
monitor the amount of water consumed by future ten-
ants and uses. Table 4.7-3 presents estimates of do-
mestic water demand for this alternative.

TABLE 4.7-3
Estimated Domestic Water Usage -
Alternative 2 - Recreation/Tourism

Estimated Estimated Estimated
Employees Domestic Domestic
Water Usage Water Usage
(gallons per (gallons per
day/per unit) day)
Park 100 20 (20 gpd*100
5 gpd/visitor ) +900
# visitors * 5 gpd)
= 6,500 gpd
Assume 2000 | 20 gpd/slip 1,600- 2,000
SF office 2000
SF + 250 SF/
ial | employee = 8
Hotel Assume 5,000 (20 gpd*20
SF office 5,000 | 75 gpd/room employee)
SF + 250 SF/ + 80 rooms *75
employee = 20 gpd) =
6,400 gpd
250 parking 15 gal/visit 7,500 gpd
spaces x 2
Museum =10 estimated 20 gpd/emrplcyes (20 gpd * 10
5 epd/visit

562

Retai 20,000 + 650 SF/ 0.10 gpd/sfof | 2,000 gpd

employee=30 _gross area

Waverfront | 250 20 gpd/employee| 3,200-4,000 gpd

250 SF/ gpd/employee 2,000-2,400 gpd

=160-200
20 estimated 20 400 gpd
TOTAL | 41,890-43,990
= | | gpd
Note: Number of residential units and square footage as
of August 1998.
Sanitary Sewage

Sewage flow from the existing NUWC complex is not
metered. Typically, sewage flow is equal to about 80%
of the potable water used at most facilities.

The existing sanitary sewer serving NUWC would
continue to serve the site and the sewage would con-
tinue to be treated at the regional WPCF. The daily
sewage flow is estimated between 33,500 and 35,200
gallons. Therefore, no upgrading or rerouting of cur-
rent sewer lines would be necessary. However, for fu-

which would be required. Additions and relocations to
the existing drainage system would be implemented
to accommodate any new drainage changes that may
result from the activity.

Stormwater associated with new development would
be subject to the DEP permitting programs. Stormwa-
ter pollution prevention plans would need to be pre-
pared prior to formal approval for permit coverage.
The permit would need to include applicable compo-
nents of the sediment and erosion and control site
plan standards, site permits, and stormwater man-
agement site plans.

Steam

High-pressure steam is currently generated in the
steam plant (Building 99) and distributed through-
out the site via a contiguous system. It is antici-
pated that Building 99 would no longer be used for
steam generation.

Electrical

Electrical service would continue to be provided by
Connecticut Light and Power (CL&P). The maximum
historical electrical demand at NUWC was 4243 kV or
4714 KVA. During this time period the incoming
feeder was loaded to 88% of its rated capacity. Addi-
tionally, there is only one electrical feed that is me-
tered for one owner. Assuming multiple users of
electricity under this alternative, sub-metering of the
current electrical system or the installation of addi-
tional electrical feeds would be required. Given the
potential for different and varied electrical needs of
future tenants, specific future amounts of electrical
consumption cannot be predicted at this time. How-
ever, given comparable levels of usage between the

564

alternative build-out and the historical demand at

NUWC, differences in electrical demand would not be
significant.

4.7.4 Alternative No. 3 - Residential/Commercial
Water Supply

Potable water would continue to be obtained from the
City of New London. Per capita water usage is esti-
mated to be 75 gallons per day per resident. Esti-
mated water usage under this alternative is between
105,230 and 106,830 gpd. This is less than historic
usage in the Fort Trumbull area, and only slightly
greater than existing estimated demands. Flow me-
ters that are currently in place to monitor water us-
age are inoperable and would have to be repaired and
or replaced in order to monitor the amount of water
consumed by future tenants and uses. Table 4.7-4
presents estimates of domestic water demand for this
alternative.

565

TABLE 4.7-4
Estimated Domestic Water Usage -
Alternative 3 - Residential/Commercial

Estimated | Estimated
Domestic | Domestic
d Estimated Water Usage Water Usage
= Employees | (gpd/unit) (gpd)
State Park 50 20 gpd/ | (20 gpd * 100
employee employee) +
5 gpd/visitor | (900 visitors *
5 gpd) = 6,500
Columbia Asseme 2000SF| 20gpd | 1,600-2,000
Cove Area office 20,000 SF gpd
+ 250 SF/
employee = 8
Open Spare 0.09 employee/
acre x 3.5 ac =0
identi 135 SFA/SFD x 3.575 gpd/person| 35,440 gpd
identi 160 TH/APT x 3.5|75 gpd/person| 42,000 gpd
=
Office 50,500 + 250SF/| 20 gpd/ 4,040 gpd
(existing) __| employee=202 | employee
Office/Incubator 250 SF/ 20 gpd/ 2,400 gpd
employee = 120 | employee
250 SF/ 20 gpd/ 400 gpd
employee = 20 | employee
= 20,000 + 650 SFY | 0.10 gpd/sf of} 2,000 gpd
. employee = 31 area
fater-related | 250SF/employee| 20 gpd/ 2,000-2,400
ame = 100-120 employee | __gpd_
Waterfront 250 SF/employee| 20gpd/ | 3,200-4000
Commercial = 80-100 employee | __gpd
WWTP 20 estimated 20 gpd/ 400 gpd
employee

566

2.9 ac x 7 dwell- |75 gpd/person| 5,250 gpd
ings/ac x 3.5
persons/unit = 70
persons
TOTAL 105,230-
106,830 gpd_

Note: Number of residential units and square footage as
of August 1998.

Sanitary Sewage

Sanitary sewage generation would be between 84,200
and 85,500 gallons per day. However, for future bill-
ing purposes, meters would have to be installed at dif-
ferent discharge points of each parcel/building in
order to monitor usage.

Stormwater Systems

The existing surface water drainage system at NUWC
is controlled by a series of catch basins and under-
ground piping. As over 20 buildings would be demol-
ished and new parking spaces would be provided,
additions and relocations to the existing drainage sys-
tem would be implemented to accommodate stormwa-
ter discharges. Any construction activities associated
with the development of this alternative would be
subject to DEP permitting programs.

Steam

It is anticipated that Building 99 would no longer be
utilized for steam generation.

567

Electricity

Specific electrical demand cannot be estimated at this
time. However, sub-metering of the current electrical
system, or the installation of additional electrical
feeds, would be required due to multiple users of elec-
tricity.

4.7.5 Alternative No. 4- Business Campus Water
Supply

Potable water would continue to be obtained from the
City of New London. Per capita water usage is esti-
mated to be 20 gallons per day per employee. Esti-
mated water usage is estimated between 67,565 and
71,665 gallons per day. This is less than histuric and
estimated current water usage in the Fort Trumbull
area. Additionally, flow meters that are currently in-
stalled to monitor water usage are inoperable and
would have to be repaired and/or replaced in order to
monitor the amount of water consumed by future ten-
ants and. uses. Table 4.7-5 presents estimates of do-
mestic water demand for this alternative.

Sanitary Sewage

Sanitary sewage generation is estimated to be be-
tween 54,100 and 57,300 gallons per day. However, for
future billing purposes, meters may have to be in-
stalled at different discharge points of each par-
cel/building in order to monitor usage.

568

TABLE 4.7-5
Estimated Domestic Water Usage -
Alternative 4 - Business Campus

| Estimated | Estimated
Domestic Domestic
Water Usage Water Usage
Land Estimated | (gallons per | (gallons per
Use/Type Employees _ day/per unit) day)
te Park 50 20 (20 gpd * 50
gpd/employee | employee) +
5 gpd/visitor | 450 visitors *
5 gpd) =
3,250 gpd
Columbia §Assume2,000SF 20gpdslip 1,600-2,000
CoveArea office 2,000 SF +
250 S/F
employee = 8
Hotel 200 rooms 50 gpd/unit 10,000 gpd
Residential 30 SFA/SFDx3.5 75 gpd/person | 7,875 gpd
persons/unit
Office 50,500 SF/250 | 20 gpd/unit 4,040 gpd
(existing) SF/ employee
= 202
Office 380,000- 20 gpd/ 30,400-32,400
405,000/250 employee gpd
SF/employee =
1,520-1,620
employee
D/Office | 5,000/250 = 20 20 gpd/ 400 gpd
| employee
Retail 250 SF/ 20 gpd/ 1,200 gpd
employee = 60 employee
Water-related| 25,000-30,000+| .10gpd/sfof |2,500-3,000
Commercial 650 SF/ gross area
Water front 20 gpd/ _—1,600-2,000
Commercial employee Bo

569
160 dwellings/ac| 20gpd/ _3,200-4,000 gpd.
employee

Residential | 0.8 acx7dwell-| 75 gpd/person | 1,500 gpd
(existing) ings/ac x

3.5 persons/unit

= 70 persons
TOTAL 67,565-71,665
gpd
Note: Number of residential units and square footage as
of August 1998.
Stormwater Systems

Additions and relocations to the existing drainage
system would be implemented to accommodate any
new drainage changes that may result from the activ-
ity. As is the case with the Residential/Commercial al-
ternative, any construction activities associated with
the development of the Business alternative would be
subject to the NPDES permit program.

Steam

Building 99 would be located within the Of-
fice/Incubator component of this reuse alternative. It
is anticipated that Building 99 could provide steam to
other non-military-retained buildings. However, sub-
metering at points of use would have to be imple-
mented in order to monitor usage.

Electricity

Specific electrical demand cannot be estimated at this
time. However, sub-metering of the current electrical
system, or the installation of additional electrical
feeds, would be required due to multiple users of elec-
tricity.

570

4.7.6 Alternative No. 5 - Mixed Use 1
Water Supply

Potable water would continue to be obtained from the
City of New London. Estimated water usage under
this alternative would be between 70,660 and 71,860
gallons per day. This is less than historic usage in the
Fort Trumbull area and approximately equal to exist-
ing estimated usage in the area. Table 4.7-6 presents
estimates of domestic water demand for this alterna-
tive.

Sanitary Sewage

Sanitary sewage generation is estimated to be be-
tween 56,500 and 57,500 gallons per day. However, for
future billing purposes, meters would have to be in-
stalled at different discharge points of each par-
cel/building in order to monitor usage.

Steam

It is anticipated that Building 99 would no longer be
used for steam generation.

Electricity

As is the case with the other alternatives, specific
electrical demand cannot be estimated at this time.
However, sub-metering of the current system or the
installation of additional electrical feeds would be re-
quired because multiple users of electricity are also
anticipated.

Estimated [Estimated

Domestic Domestic

Estimated Water Usage Water Usage

Employees (gallons per (gallons

or Units day/per unit) per day)

State Park 50 20 gpd/ (20 gpd * 50

employee5 | employee) +

gpd/visitor 450 visitors * 5

\gpd = 3,250

Columbia Assume 2,000 20 gpd/slip 1,600-2,000
Cove office 2,000 SF +
Area 250 SF/
employee = 8

Assume 10,000 20 gpd/ (20) gpd * 40

SF office 10,000; employee employee) +

SF+250SF/ | 75gpd/room 200 rcoms * 75

GPD) =

15,800 gpd

2,250 gpd

30,320 gpd

4,040 gpd

400 gpd

1,000 gpd

400

v2 573

WWTP 40 estimated 20 gpd/ 400 gpd

Athletic 25,000SF x6 | 15gal/visitor | 2,250 gpd
employee Club/Field visits/day/
TOTAL ae a 1,000 SF
Note: Number of residential units and square footage as co ”
of August 1998. a
Office 50,500 + 250 20 gpd/ 4,040 gpd
4.7.7 Alternative No. 6 - Mixed Use 2 Water Supply (existing) SF/employee employee
Potable water would continue to be obtained from the aa 20 gpd/ 400 gpd
City of New London. Estimated water usage under employee = 20

this alternative would be between 74,410 and 75,610
gallons per day. This is less than historic usage in the
Fort Trumbull area and approximately equal to exist-

ing demands. Table 4.7-7 presents estimates of do- | .
mestic water demand for this alternative. Cnr — A A ee

emplovse
TABLE 4.7-7 = 100 120
Estimated Domestic Water Usage - 25u SF/ 20 gpd/ ——
Alternative 6 - Mixed Use 2 — employee
WWTP 40 estimated 20 gpd/ 400 gpd
employee
74,410-75,610
_gpd
Note: Number of residential units and square footage as
of August 1998.
Sanitary Sewage

Sanitary sewage generation is estimated to be be-
tween 59,500 and 60,500 gallons per day. However, for
future billing purposes, meters would have to be in-
stalled at different discharge points of each par-
cel/building in order to monitor usage.

48

574

Steam and Electricity

Impacts to steam generation and electricity for Alter-
native 6 are the same as those for Alternative 5.

Cultural Resources Impacts

Future development in the Fort Trumbull MDP area
will include ground disturbances from machine ac-
cess, demolition of some existing structures, construc-
tion of new buildings, utility installation, and land

plans
will have varying affects on different parts of the pro-
ject area, and possibly associated archaeological sites.
Archeological reconnaissance surveys (Phase lb) are
planned in all areas that have been identified in the
archaeological assessment surveys (Reeve, Keegan
and Keegan 1998; TAMS 1998) as moderately and
highly sensitive for prehistoric or historic period ar-
are anticipated.

Archeological investigations should not prevent fu-
ture deve'oupment of the project area. Representatives
of the Connecticut Historical Commission (CHC) have
indicated that Phase lb, and, if necessary, Phase 2
and Phase 3 level investigation, can proceed over the
long term as development plans and construction
schedules are adopted. CHC has further indicated a
willingness to work closely with all parties to assure
protection of significant historic resources and to as-
sure the success of New London revitalization.

In any of the alternatives, structures on the NWUC

demolition of currently registered
contemplated, it is likely that some or all of the other

575

structures on this property would be destroyed in the
implementation of various alternatives. Based on the
building ‘nventory presented in Section 2.3.3, reuse
and rehabilitation of most of these buildings would be
likely for Building 34 (Bowditch Hall) and Building 14
within the public sale portion of NUWC. These are
described in detail in Section 2.7.2 of this document.
Numerous mitigative measures have been proposed to
offset impacts to cultural resources. These are de-
scribed in Section 5.0 of this document.

4.8.1 Alternative No. 1 - No Action

Hypothetically, any archeological resources off the
NUWC property would be preserved under this alter-
native. Due to the potentially sensitive contexts of
certain properties in this area, the City of New Lon-

ing land use on a parcel-by-parcel basis. However,
there is no mandatory or programmatic requirement
to do so. Therefore, with no firm commitment to con-
sources may be lost if the no action alternative were
pursued as compared with the other alternatives.

The LRA’s preferred reuse plan for NUWC contem-
plates the reuse of five buildings (Buildings 2, 80, 96,
99, and 101) in the public sale portion of the property,
as well as restoration and reuse of Buildings 13, 14,
27, 32, and 42 for office and as attractions. Buildings
41, 44, 34, 28, and 94 (which have been identified as
eligible structures) would be demolished.

576

4.8.2 Alternative No. 2 - Recreation/Tourism

Moderately to highly sensitive archeological areas are
crossed by the state park expansion, the riverfront
walkway, and the Pequot Avenue R&D area. Specific
areas are likely to be affected by hotel construction,
cultural museum/active recreation, the recreation
center, and office/incubator construction. Archeologi-
cal investigations should provide substantial thematic
contexts for museum programs, exhibits, and tour-
ism in this alternative. Substantial areas contain-
ing archeological sites might be preserved in this
plan. Most, if not all of the identified eligible struc-
tures in the future development area at NUWC
would be demolished. This is also true for Alterna-

tives 3 through 6.

4.8.3 Alternative No. 3 - Residential/Commercial
Residential development may be able to incorporate

preserved. Archeological sites identified in the R&D,
office/incubator, and retail] areas are expected to have
intensive ground modifications that may require data
recovery of significant archeological sites, if found.

4.8.4 Alternative No. 4 - Business Campus

As in other alternatives, the business campus devel-
opment is expected to affect moderately to highly sen-
sitive archeological areas, with few opportunities for
- 4 space preservation of identified archeological

4.9

577

4.8.5 Alternative No. 5 - Mixed Use 1

Similar to Alternative 3, residential and recreational
development can be designed to incorporate archeo-
logical site preservation in the open space areas.
Office/incubator, R&D, and hotel/conference center
development are less adaptable for archeological
preservation.

4.8.6 Alternative No. 6 - Mixed Use 2

Impacts associated with Alternative 6 would be simi-
lar to Alternative 5, except that the larger area of
open space designated in the eastern portion of the
MDP area would result in less ground disturbance
and, therefore, be more adaptable for archeological
preservation.

Traffic and Parking Impacts
4.9.1 Traffic Generation

Analyses required to assess existing (1998) and future

year (2010) anticipated traffic volumes (with and
without site traffic) for the weekday AM. and PM.
peak highway hours are based on manual turning
movement counts conducted on Thursday, August 13,
1998, and on Fridays, August 14 and 21, 1998. The
turning movement counts for the periods
7:00 A.M.-9:00 A.M. and 4:00 PM.-6:00 PM. deter-
mined that weekday peak commuter hours are from
8:00-9:00 AM. and 4:15-5:15 PM. Existing (1998)
weekday A.M. and P.M. traffic volumes are presented
in Appendix D (Figures 1 and 2, respectively). Based
on existing traffic patterns and proposed development
land uses, it is anticipated that the most intense traf-
fic impacts will occur during the weekday A.M. and
P.M. peak commuter hours.

578

Future year 2010 projected traffic volumes without
Fort Trumbull MDP development consists of expan-
sion of existing year 1998 traffic volumes by 1.0% per
year compounded annually plus the addition of peak
hour traffic generated by the Pfizer facility. Estimated
2010 traffic volumes for the A.M. and P.M. weekday
peak commuter hours, without the Fort Trumbull
MDP area development, are presented in Appendix D
(Figures 3 and 4, respectively).

Anticipated future year traffic generated by the pro-
posed Fort Trumbull MDP were developed for six de-
velopment alternatives including:

Alternative 1 — No Action Alternative;

Alternative 2 — Recreation/Tourism Alternative;
Alternative 3 — Residential/Commercial Alternative;
Alternative 4 — Business Park Alternative;
Alternative 5 — Mixed Ll se 1; and

Alternative 6 — Mixed Use 2.

Estimates of anticipated traffic generated by these al-
ternatives were developed for the various proposed
land uses in the MDP area using the Institute of
Transportation Engineers’, “Trip Generation” publica-
tion, 6th Edition. Trips generated by existing office
space (50,500 square feet) are based on General Office
Building trip generation rates (ITE Land Use 710),
whereas proposed office/incubator and Research &
Development office spaces are based on ITE Land Use
760 for Research and Development Center Uses.

Projected traffic generation is summarized in Table
4.9-1.

579

TABLE 4.9-1

Summary of Projected Traffic Counts

Condition | A.M. | P.M.
EnteringExitingEnteringExi

Alternative 1 - - 1,081 326 333 961
No Action

Alternative 2 - 690 402 280 565
Recreation/Tourism

Alternative 3 - 575 478 341 495
Residential/
Commercial

Alternative 4 - 973 466 337 812
Business Campus

Alternative 5 - 654 417 315 541
Mixed Use 1

Alternative 6 - 671 428 331 556
Mixed Use 2

Development Alternatives 1, 4, and 6 represent high
trip generations relative to the six development alter-
natives and are used for analysis in this report. Ta-
bles 4.9-2 and 4.9-3 present a breakdown of the
anticipated site trips generated during the weekday
A.M. and P.M. peak highway hours for Alternatives 4
and 6, respectively.

Site traffic is distributed over the study area roadway
system based on existing traffic patterns and distri-
bution patterns presented in previous traffic reports
for developments in the area, including the traffic
study for Pfizer’s adjacent facility. The distribution
pattern used for the MDP area is as follows:

77% of the site traffic is oriented to and from the
north and east, by way of Howard Street and
Bank Street through New London’s Central
Business District, to/from the I-95 interchange;

580

© 8% of the site traffic is oriented to and from the
north and west by way of Bank Street using
Howard Street and Shaw Street for access;

© 10% of the site traffic is oriented to and from the
west by way of Willetts Avenue; and

¢ 5% of the site traffic is oriented to and from the
south by way of Pequot Avenue.

Alternatives 4 and 6 include approximately 12 land
use areas within each alternate. For purposes of traf-
fic analyses, access to development area is grouped
within each alternate by a common access via Hamil-
ton Street via the intersection of Howard Street/
Walbach Street, via the intersection of Trumbull
Street/Pequot Avenue, via Trumbull Street and via
Walbach Street.

Site generated traffic in Alternatives 4 and 6 were
superimposed on the future year base traffic volumes
to create future year (2010) combined traffic volumes
for the weekday A.M. and P.M. peak highway hours.
Appended Figures 5, 6, 7 and 8 present the combined
traffic volumes for each scenario (Appendix D).

581

Anticipated Site Generated Traffic
Alternate 4 — Business Campus Alternate

Fort Trumbull MDP, New London, Connecticut

Land Use Size ITE Weekday Trip Generation Rate Weekday Generated Vehicle Trips
Code AM PM Daily AM PM Daily
Enter | Exit | Enter| Exit | Enter| Exit | Enter | Exit | Enter | Exit | Enter | Exit
PENINSULA AREA
State Park 16.0 Acres - - - - - 45 5 10 40 100 100
Columbia Cove Marina| 100 Slips 420 | 0.03 | 0.05 | 0.11 | 0.08 | 1.48 | 1.48 3 5 1l 8 148 148
Hotel/Conference 200 Rooms 310 | 0.34 | 0.22 | 0.32 | 0.29 | 4.12 | 4.12 68 44 64 58 824 824
Center
Office/Incubator 375,000 760 | 1.03 | 0.21 | 0.16 | 0.92 | 4.06 | 4.06 | 386 79 60 345 | 1,523 | 1,523
Water Related 30,000 sq. ft. 814 | 3.08 | 3.33 | 1.11 | 1.48 | 20.34 | 20.34| 93 100 34 45 610 610
Commercial
Waste Water 40 Employees - - - - - - - (30) (4) (6) (30) | (60) | (60)
Treatment Plant — (Assumes 3 shifts with 30 employees on first shift, 6
employees on second shift and 4 employees on third
shift)
Peninsula Area Sub Totals | 625 237 185 526
GATEWAY AREA
Residential 30 Single 270 | 0.11 | 0.40 | 0.40 | 0.22 | 3.75 | 3.75 4 12 12 7 113 113
Family
attached/
detached units =”
Office (Existing) 50,500 sq. ft. 710 | 1.37 | 0.19 | 0.25 | 1.24 | 5.51 | 5.51 69 10 13 63 278 278
Retail/ 3,750 sq. ft. 852 | 15.51 | 15.51 | 16.94 | 17.63 - - 58 58 64 66 - -
Specialty Retail 11,250 sq. ft. 814 | 3.08 | 3.33 | 1.11 | 1.48 | 20.34 | 20.34); 35 38 13 17 229 229
R & D Office 70,000 sq. ft. 760 | 1.03 | 0.21 | 0.16 | 6.92 | 4.06 | 4.06 72 15 12 65 305 305
Waterfront Commercial | 25,000 sq. ft. 814 | 3.08 | 3.33 | 1.11 | 1.48 | 20.34 | 20.34} 77 84 28 37 509 509
Residential (existing) |8dwellingunits; 210 | 0.19 | 0.56 | 0.65 | 0.36 | 4.79 | 4.79 2 5 5 3 38 38
(existing)
Office/Incubator 30,000 sq. ft. 760 1.03 | 0.21 | 0.16 .92 4.06 | 4.06 31 7 5 28 122 122
Gateway Area Sub Totals | 348 229 152 286
TOTALS 973 466 337 #812

(xx) Estimated

582

ANTICIPATED SITE GENERATED TRAFFIC

Alternate 6 — Mixed Use Alternate #2

Fort Trumbull MDP, New London, Connecticut

(xx) Estimated
Notes: 1.

January 23, 1998, prepared by TAMS, page 4.4-2 and Table 4.4-1.
Wilbur Smith Associates

DEIS — Disposal and Reuse of Naval Underwater Warfare Center, New London, Connecticut;

Land Use Size ITE Weekday Trip Generation Rate Weekday Generated Vehicle Trips
Code AM PM Daily AM PM Daily
Enter | Exit | Enter | Exit | Enter | Exit | Enter| Exit | Enter| Exit | Enter| Exit
PENINSULA AREA
State Park 16 Acres (Note 1)}_ - - - - - - 45 5 10 40 100 100
Columbia Cove Marina} 100 Slips 420 | 0.03 | 0.05 | 0.11 | 0.08 | 148 | 1.48 3 5 1l 8 148 148
Hotel/Conf Center 250 Rooms 310 | 0.34 | 0.22 | 0.32 | 0.29 | 4.12 | 4.12 85 55 80 73 1030 | 1030
Athletic 25,000 sq. ft. 492 | 0.73 | 0.73 | 0.92 | 0.92 | 8.57 | 8.57 19 19 23 23 215 215
Club/Field (Assumes 50% in, 50 percent out)
Residential Mid-Range|115 Units | 270 0.11 | 0.40 | 0.40 | 0.22 | 3.75 | 3.75 13 46 46 25 432 432
(Single family attached
and deatched units)
Water Related 30,000 sq. ft. 814 | 3.08 | 3.33 | 1.11 | 1.48 | 20.34 | 20.34)| 93 100 34 45 610 610
Commercial
Waste Water 40 Employ - - - a i - - (30) (4) (6) (30) | (60) | (60)
Treatment Plant Plant (Assumes 3 shifts with 30 employees on first shift, 6
employees on second shift and 4 employees on third
shift)
Peninsula Area Sub Totals| 288 234 210 # £244
GATEWAY AREA =
Office (Existing) 50,500 sq. ft. 710 | 1.37 | 0.19 | 0.25 | 1.24 | 5.51 | 5.51 69 10 13 63 278 278
Office/Incubator 100,000 sq. ft.| 760 | 1.03 | 0.21 | 0.16 .92 4.06 | 4.06 | 103 21 16 92 406 | 406
Retail/ 2,500 sq. ft. 852 | 15.51 | 15.51 | 16.94 | 17.63 - - 39 39 43 44 - -
Specialty 7,500 sq. ft. 814 | 3.08 | 3.33 | 1.11 | 1.48 | 20.34 | 20.34) 23 25 9 11 153 153
R & D Office 70,000 sq. ft. 760 | 1.03 | 0.21 | 0.16 | 0.92 | 4.06 | 4.06 72 15 12 65 305 305
Waterfront Commercial | 25,000 sq. ft. 814 | 3.08 | 3.33 | 1.11 | 1.48 | 20.34 | 20.34} 77 84 28 37 509 509
Gateway Ar

[Text truncated at 120,000 characters. The full text is on the page linked above.]

---